Model: 6246 12v – 4.5Ah Memory Saver OWNER’S MANUAL PLEASE SAVE THIS OWNERS MANUAL AND READ BEFORE EACH USE. This manual will explain how to use the memory saver safely and effectively. Please read and follow these instructions and precautions carefully. Rev. 20150123 CONTENTS IMPORTANT SAFETY INSTRUCTIONS ................................................................................ 3 PERSONAL SAFETY PRECAUTIONS .................................................................................. 3 CHARGER AND AC POWER CORD CONNECTIONS .......................................................... 4 ASSEMBLY INSTRUCTIONS ................................................................................................. 4 FEATURES ............................................................................................................................. 4 CHARGING THE INTERNAL BATTERY OF THE MEMORY SAVER .................................... 4 OPERATING INSTRUCTIONS ............................................................................................... 5 MAINTENANCE AND CARE .................................................................................................. 6 SPECIFICATIONS .................................................................................................................. 6 CONTAINS SEALED NON-SPILLABLE LEAD-ACID BATTERY. MUST BE DISPOSED OF PROPERLY. CONTIENE UNA BATERÍA SELLADA DE ÁCIDO-PLOMO NO DERRAMABLE QUE DEBE DESECHARSE APROPIADAMENTE. CONTIENT UNE BATTERIE À L’ACIDE QUI DOIT ÊTRE DISPOSÉ CORRECTEMENT. WARNING: Possible explosion hazard. Contact with battery acid may cause severe burns and blindness. Keep out of reach of children. ADVERTENCIA: Posible Riesgo de una explosión. El contacto con una batería de ácido puede causar quemaduras y ceguera. Manténgase alejado de los niños. AVERTISSEMENT : Hasard d’explosion possible. Contact avec l’acide de batterie peut provoquer sévère brûle et la cécité. Ne le laissez pas a la portée des enfants. IMPORTANT SAFETY INSTRUCTIONS WARNING – RISK OF EXPLOSIVE GASES WORKING IN THE VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL OPERATION. FOR THIS REASON, IT IS IMPORTANT THAT YOU FOLLOW THESE INSTRUCTIONS EACH TIME YOU USE THE MEMORY SAVER. To reduce the risk of a battery explosion, follow these instructions and those published by the manufacturer of the battery and any equipment you intend to use in the vicinity of the battery. Review the cautionary markings on these products and on the engine. WARNING: Pursuant to California Proposition 65, this product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling. • Read the entire manual before using this product. Failure to do so could result in serious injury. • Use the memory saver in a well-ventilated area. • This memory saver is not intended for use by children. • Do not expose the memory saver to rain or snow. • Do not operate the memory saver if it has received a sharp blow, been dropped or otherwise damaged in any way; take it to a qualified service person. • Inspect the battery for a cracked or broken case or cover. If the battery is damaged, do not use the memory saver. • Do not disassemble the memory saver; take it to a qualified service person when service or repair is required. Incorrect reassembly may result in a risk of fire or electric shock. PERSONAL SAFETY PRECAUTIONS • Wear complete eye protection and protective clothing when working near lead-acid batteries. Always have someone nearby for help. • Have plenty of fresh water, soap and baking soda nearby for use, in case battery acid contacts your eyes, skin, or clothing. Wash immediately with soap and water and seek medical attention. • If battery acid comes in contact with eyes, flush eyes immediately for a minimum 10 minutes and get medical attention. • Neutralize any acid spills thoroughly with baking soda before attempting to clean up. • Remove all personal metal items from your body, such as rings, bracelets, necklaces and watches. A battery can produce a short circuit current high enough to weld a ring to metal, causing a severe burn. • Never smoke or allow a spark or flame in the vicinity of the battery or engine. •3• CHARGER AND AC POWER CORD CONNECTIONS The memory saver’s charger is for use on a nominal 120 volt circuit. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances. The plug pins must fit the receptacle(outlet). Do not use with an ungrounded system. NOTE: Use of an adapter plug in the United States is not recommended and should not be used. ASSEMBLY INSTRUCTIONS Remove all cord wraps and uncoil the cables prior to using the memory saver. FEATURES USB switch button / status LED USB outlet Internal battery charging status LEDs Internal battery status button / status LEDs 12V DC power outlet Charging inlet OBD connector with 3ft cable CHARGING THE INTERNAL BATTERY OF THE MEMORY SAVER IMPORTANT: CHARGE IMMEDIATELY AFTER PURCHASE, AFTER EACH USE AND EVERY 30 DAYS, TO KEEP THE MEMORY SAVER’S INTERNAL BATTERY FULLY CHARGED. • To reduce the risk of electric shock, unplug the memory saver’s charger from the outlet before attempting any maintenance or cleaning. • When charging the internal battery, work in a well ventilated area and do not restrict the ventilation in any way. LED INDICATORS To check the internal battery’s charge status, press the Battery Status button on the front of the memory saver. The LED lights indicate the charge level, as follows: (red) LED – The memory saver is • charging (connected to an AC power source.) • (yellow/orange) LED – Indicates a 50-75% charge. The memory saver may be used, but should be recharged as soon as possible. (green) LED – The internal battery is fully • charged. •4• CHARGING THE INTERNAL BATTERY USING THE 1. To charge, plug the charger connecter into the charging inlet on the back of the memory saver. 2. lug the charger into a 0 electrical wall outlet. 3. The R I (red) LED will glow, indicating charging. 4. The R ED (green) LED will light when the battery has reached full charge. This could take up to 7 hours, depending on the age and condition of the battery. The charger will automatically go into maintain mode and maintain the battery at full charge without damaging it. 5. harge the memory saver as soon as possible after use. NOTE: To reduce the risk of damage to the adaptor or cord, pull by the plug rather than the cord when disconnecting the memory saver’s charger. You may also charge the internal battery while driving, using a male-to-male charger cable (not included). NOTE: se a male-to-male adaptor only for charging the internal battery. You must use the BD onnector to save memory. IMPORTANT: D T R E I TER L B TTERY R M RE T 0 MI TES R LE E T E B TTERY TTE DED. IT LD E L DE, SI R ERTY D M E R ERS L I J RY. 1. ake sure the car is running. 2. Insert one end of the accessory cable into the D power outlet. 3. Insert the other end of the accessory cable into the vehicle’s accessory outlet (lighter socket). NOTE: The R I (red) LED and the R ED (green) LED do not operate during this method of charging. Using this method to charge the battery overrides the maintain mode and the battery can be overcharged. 4. onitor the progress of the charge by pressing the Battery Status button on the front of the unit. When it reaches a full ( 00%) charge, disconnect the accessory cable from the memory saver, then from the lighter socket of the vehicle. NOTE: ompletely disconnect the charger cable when the engine is not running. OPERATING INSTRUCTIONS se the memory saver to save the vehicle’s on-board diagnostic computer settings (radio programs, diagnostic codes, etc.) while the battery is disconnected from the vehicle during repair or maintenance. NOTE: Some vehicle manufacturers do not allow the use of a memory saver through the OBDII. Consult the vehicle manufacturer before use, to determine if a memory saver is acceptable for use on the vehicle. BEFORE USING THE MEMORY SAVER ake sure that the memory saver’s internal battery is fully charged. See LED I DI T RS section. 1. ake sure the unit is fully charged. 2. Turn off the vehicle, remove the key, and make sure all accessories are off. WARNING: erify all vehicle accessories are (fan, interior lights, etc.). eadlights must be in position, not T position. To prevent overloading of a vehicle fuse or other vehicle damage, do not use the memory saver through the BDII port if the vehicle’s current draw is 4 amps or more when the vehicle is in a EY condition (use an amp clamp to measure the amperage draw). If unable to measure the vehicle’s current draw, turn the vehicle’s key to the position and wait •5• 5 minutes. This ensures that all retained accessories are in a power state (for e ample: fan, headlights, etc.). 3. onnect the BD diagnostic connector to the vehicle’s BD plug. ake sure the connector is fully engaged. 4. Disconnect the vehicle’s battery cables and cover the positive and negative cables with an insulator, such as electrical tape. This prevents the connectors from touching metal, each other, or the chassis and causing a short circuit, due to the vehicle’s electrical system receiving power through the BD connection. WARNING: When working with the vehicle’s battery, review all of the battery manufacturer’s safety instructions, warnings and directives regarding battery disconnection, removal and replacement. 5. Remove the old battery and put the new battery into position. 6. Remove the insulator from the positive cable and connect it to the positive terminal of the new battery. 7. Remove the insulator from the negative cable and connect it to the negative terminal of the new battery. 8. nce the new battery is connected, unplug the memory saver’s BD connector from the vehicle’s BD plug. POWERING A 12V DC DEVICE: The memory saver is a power source for all D accessories that are e uipped with a accessory plug. se it for power trip and disconnect the power to the device. Disconnect the D device. The breaker will automatically reset after an overload occurs. IMPORTANT: The D power outlet is wired directly to the internal battery. E tended operation of a D device may result in e cessive battery drain. Recharge immediately after unplugging the D device. IMPORTANT: Do not power a device with the memory saver while using the BD connector to power the on-board diagnostic computer. Doing so will drain the memory saver’s internal battery and reduce available run time. ake sure the device to be powered is before inserting the D accessory plug into the D accessory outlet. 1. pen the protective cover of the D power outlet on the front of the memory saver. 2. lug the D device into the D power outlet, and turn on the D device (if re uired). 3. If the D device draws more than 15A or has a short circuit, the internal circuit breaker of the memory saver will USING USB OUTLET: The memory saver provides SB outlet for SB charging. 1. lug the SB cable into the SB outlet. 2. ress the SB switch button to open SB output, the SB status LED will glow, indicating SB output is on. 3. ress the SB switch button again once finished using. MAINTENANCE AND CARE • se a dry cloth to wipe all battery corrosion and other dirt or oil from the cords and the memory saver case. • oil the input and output cords neatly when storing the memory. This will help prevent accidental damage to the cords and unit. • Store the memory saver in an upright position. • Store inside, in a cool, dry place. Do not use and/or store the memory saver in or on any area or surface where damage could occur Text if the internal battery should une pectedly leak acid. SPECIFICATIONS Internal Battery Type.......................................................... aintenance- ree Lead- cid ominal Voltage........................................................................................................... D 4.5Ah apacity .............................................................................................................................5 Ah onnector ....................................................................................................................... BDII D SB ower utlet ( BD ort and D utlet) a imum ontinuous Load .......... D , 5 utlet .............................................................................................................. 5 D , • •