All-In-One
DEWE2
DEWE-3300
Most portable all-in-one instrument
16 isolated DAQP or 32 differential MDAQ analog inputs
2 PCI slots for A/D cards
Choose from two models
Add your choice of signal conditioning,
A/D board(s) and software to complete these systems
DEWE-3300
Input specifications
Slots for DAQ or PAD modules
DEWE-3301
16
Up to 32
Total PCI slots
2 half length
1 TB HDD dedicated for data storage (upgrade to 1 TB SSD available)
120 GB SSD for operating system and application software,
both in a single removable drive bay
Hard disk
Data throughput
Typ. 80 MB/s
Power supply (max.)
Optional: 8 to 30 VDC
Display
95 to 260 VAC
(external AC power supply included)
15.4“ TFT wide-screen with multitouch-screen (1280 x 800)
Processor
Intel® Core™ i5
RAM
4 GB
Ethernet
2x 10/100/1000 BaseT
USB interfaces
6
Operating system
Microsoft® WINDOWS® 7
Dimensions (W x D x H)
462 x 320 x 135 mm (18.2 x 12.6 x 5.3 in.)
Weight
Typ. 8.2 kg (18 lb.)
Typ. 8 kg (17.6 lb.)
Environmental specifications
Operating temperature
0 to +50 °C, down to -20 °C with prewarmed unit
Storage temperature
-20 to +70 °C
Humidity
10 to 80 % non cond., 5 to 95 % rel. humidity
Max. Altitude
2000 m (6560 ft)
Sine vibration (EN 60068-2-6)
Shock (EN 60028-2-27)
Acceleration 15 g, duration 11ms, pulse form half sine, 3 pumps/direction, 6 directions
2)
Random vibration (EN 60721-3-2)
1)
2)
Acceleration 20 m/s², Freq. 10 Hz - 150 Hz, Sweep 1 oct/min, 20 cycles
2)
2)
Class 2M2 (spectral acceleration density 1 m²/s³, frequency range 10 Hz-200 Hz, duration 30 min/direction)
Please find current specifications in the latest price list
Tested with Solid State Disk
Additional interfaces and sensors
Measurements are not limited to just classic analog and digital signals. Please find further detailed information to
expand your system in the chapter “Components”.
Options to expand the system
DEWE-ORION “A/D Boards” offer simultaneous sampled
analog inputs, synchronous digital I/Os, high-performance
counters and high-speed CAN interfaces. DAQP or MDAQ
signal amplifiers and software are needed as well.
Add further “Interface Cards” like ARINC-429, 1553, and
analog output or special “Sensors” like synchronized
video, industrial encoders (RIE-360) or GPS.
A/D card
DAQP/MDAQ
Software
Software
Needed to complete the system
Front-ends
-
Main system 1)
Signal Conditioning
MDAQ input channels
Instruments
EPAD2 interface included for up to 2 external low speed modules
Components
Quasi-static channel expansion 12 Hz
DEWE-3300
Dedicated Instruments
15.4” TFT multi-touch screen
CNT2-LEMO
VIDEO
CAN
www.dewetron.com/dewe-3300
1
DEWE-3300
DEWE-3300
Most flexible model, prepared for DAQP isolated analog input
amplifier modules. DAQP conditioners offer highest bandwidth, great accuracy, different input ranges and integrated
filters. Besides the single channel modularity – a module easily can be changed by the user at any time – the main advantage of these modules is the high galvanic isolation which
ensures safe measurements, high quality results and make
them almost indestructible. See chapter “Signal Conditioning”
for details.
Max. channel count
ANALOG
16 DAQ modules
DIGITAL
I/O card & counter & CAN
DEWE-3301
Version for sensor input via differential MDAQ analog input
amplifiers. MDAQ modules are available in cost efficient
and space saving 8-channel blocks. See chapter “Signal
Conditioning” for details.
Max. channel count
ANALOG
32 MDAQ channels
DIGITAL
I/O card & counter & CAN
Counters
The two counters of the DEWE-ORION-series A/D-card
are wired to female 7-pin LEMO sockets for direct
connection of encoders or any other counter channel
sources.
1.5 u panel space available for DIO panels in
systems with DC power option
1.5 u panel space available for DIO panels in
AC powered systems
Choose between a panel with 8 additional counter
inputs or a power supply for 4 current clamps.
0.5U-ORION-CNT8-LEMO
Depending on the application, the DEWE-3300 offers
various DIO panels. For encoder measurements the
ORION-DIO-PANEL-1 is the right choice since it offers
eight counters wired to 7-pin LEMO connectors. The
ORION-DIO-PANEL-2 has been designed for applications where many TTL-inputs are required. For galvanically isolated digital inputs the ORION-DIO-PANEL-3
would be the right choice.
330x-OUT-10
0.5U-CLAMP-DC-POWER-4
ORION-DIO-PANEL-1
ORION-DIO-PANEL-2
MPAD-TH16-K
2
www.de we t ron .com
All-In-One
System options and upgrades for DEWE-3300
0.5U-CLAMP-DC-POWER-4
0.5 U panel with 4 Lemo sockets, ±15 V power supply and digital status lines for PNA-CLAMP-150-DC,+9 V power supply
for other clamps
Options for DC powered systems only
DEWE-3300-OUT-5
16 BNC connectors on side panel, ±5 V output of conditioned signals
DEWE-3300-OUT-10
16 BNC connectors on back panel, ±10 V output of conditioned signals, max. bandwidth 300 kHz
MPAD-TH8-K
adds 8 internal thermocouple inputs type K, sampling rate 12 Hz, not applicable to all configurations, please ask factory!
MPAD-TH16-K
adds 16 internal thermocouple inputs type K, sampling rate 12 Hz, not applicable to all configurations, please ask factory!
MPAD-TH8-T
adds 8 internal thermocouple inputs type T, sampling rate 12 Hz, not applicable to all configurations, please ask factory!
MPAD-TH16-T
adds 16 internal thermocouple inputs type T, sampling rate 12 Hz, not applicable to all configurations, please ask factory!
Upgrades
Description
HDD-1T-SSD-500G
Upgrade to 500 GB flash disk (replaces 1 TB data harddisk)
HDD-1T-SSD-1T
Upgrade to 1 TB flash disk (replaces 1 TB data harddisk)
ORION Sync option
DEWE-UPS-300-DC
DEWE-UPS-300-DC
Software
The DEWE-UPS-300-DC is an external DC uninterruptible power supply with up to four
internal high capacity batteries. It can be used to power instruments with wide range DC
input for hours. A typical DEWE-3300 can be operated for approx. 4 hours using DEWEUPS-300-DC. In addition the batteries are hot-swappable and so enable you to run the
instrument infinitely by changing batteries every few hours. External battery chargers are
available, too. If the DEWE-UPS-300-DC is externally powered it also serves as a multibattery charger.
Components
Signal Conditioning
Front-ends
Synchronization with
PC based instruments
Dedicated Instruments
0.5 U panel with 8 Lemo sockets EGG.1B.307 connected to the 8 counters of an ORION base card
Instruments
0.5U-ORION-CNT8-LEMO
DEWE2
Options for all systems
DEWE-POWERBOX-12
DC Power distribution box
15.4“ multi-touch-screen
The carrying bag is
included as standard accessory
Removable drive bay
3
DEWE-3300
Channel Expansion
Signal conditioning for slow signals is added by connecting EPAD2 series modules
to the systems EPAD interface.
EPAD2-TH8
For expanding the number of dynamic channels there are some choices:
Analog cable: Additional A/D boards are installed into the basic instrument and external signal conditioning, e.g.
DAQ modules in a DEWE-30 chassis, is connected by means of an analog signal cable.
ANALOG
DEWE-3300
DEWE-30-16
DEWE-NET: Several instruments are connected via Ethernet. Each unit requires an ORION-SYNC option. For short
distances a sync cable is used if the units are far from each other a sync interface like DEWE-CLOCK is used.
ETHERNET
DEWE-3300
DEWE-3301
DEWETRON GmbH • Parkring 4 • 8074 Grambach • AUSTRIA • Tel: 0043 316 30700 • Fax: 0043 316 3070 90 • info@dewetron.com
4
www.de we t ron .com
DE-B100401E • All trademarks are acknowledged to be the property of their owners. Specification subject to change without notice. © DEWETRON GmbH
08/2015
EPAD2-TH8