SmartlockPro® Slim GFCI with Audible Trip Alert

Product Bulletin for
GFCI with Audible Trip Alert
SmartlockPro® Slim GFCI with Audible Trip Alert
Instant Audible Alert Indicates Power Interruption
GFCI protection is vital to ensure electrical safety in both residential
and commercial settings. A power interruption due to a ground
fault provides important protection to people but can shut down
freezers, sump pumps and other necessary equipment if left
undetected. Often, however, GFCIs in garages, basements or large
commercial kitchens may be located in an out-of-the-way place
such as a back corner or storage area making daily visual checks for
tripping unlikely. The new SmartlockPro Slim GFCI with Audible Alert
is the smart solution.
When a condition exists causing the SmartlockPro Slim GFCI with
Audible Alert to trip, users will be alerted by the sounding of an
audible alarm. This audible alert indicates that power has been
disconnected from loads plugged into or fed from the GFCI so users
can immediately assess the reason and reset the device. The GFCI
with Audible Alert offers all the outstanding benefits you expect
from SmartlockPro products, including our patented reset/lockout
feature. Plus, the slim profile is compact and easy to install in any
wallbox, even shallow ones.
- NEC® requirement for garages, basements, commercial kitchens
and other critical loads
- Audible alert indicates the device needs to be reset
Features and Benefits
GFCI
Slim design is easy to install in any wallbox
External wiring clamps show proper wire seating
Standard self-grounding clip
Tamper-resistant to meet the latest National Electrical Code®
child safety requirements
Reset lockout prevents reset if the GFCI is damaged and cannot
respond to a ground fault
Impact resistant face and body
Limited Two-Year Warranty
Audible Alarm
Audible alarm sounds when the GFCI trips, providing an alert that power
has been disconnected from load(s) plugged into or fed from the GFCI*
Indicator light provides visual status
*Audible alarm will NOT sound if the circuit breaker has tripped and disconnected power.
Agency Standards and Certifications
L Standard 943 Class A (GFCI) and 498 (Receptacle)
U
UL Listed (File #E48380)
CSA C22.2 - No. 144.1-06 (GFCI) and No. 42 (Receptacle)
CSA Listed (File #LR-57811)
NOM - 003: ANCE
Meets Federal Specification WC-596
INDICATOR LIGHT AND AUDIBLE ALERT
GFCI Status
Light
Audible Alert
Power
GFCI Properly Wired
Tripped (RESET button out)
On
On
Off
Set (RESET button in)
Off
Off
On
GFCI Miswired (line/load reversed)
Tripped (RESET button out)
Set (RESET button in)
Off
Off
n/a - will not reset
n/a - will not reset
OFF- Review instructions for correct wiring
Dimensional Drawing
1.31in 33.4mm
1.31in 33.4mm
LINE NEUTRAL
TERMINAL
2.70in 68.6mm
6-32 THREAD
(2 PLACES)
3.27in 83mm
LINE PHASE
TERMINAL
1.29in 32.6mm
2.60in 66.1mm
2.70in 68.7mm
4.21in 106.9mm
2.60in 66mm
3.27in 83mm
3.81in 96.8mm
6-32 THREAD
(2 PLACES)
3.81in 96.8mm
NEUTRAL
NAL
1.28in 32.6mm
.047in 1.19mm
4.21in 106.9mm
1.29in 32.6mm
1.28in 32.5mm
.047in 1.19mm
LINE PHASE
TERMINAL
LOAD PHASE
TERMINAL
LOAD PHASE
LOAD
NEUTRAL
TERMINAL
TERMINAL
NEUTRAL
NAL
1.07in 27.2mm
1.07in 27.2mm
GREEN GROUND SCREW
GREEN GROUND SCREW
1.43in 36.3mm
1.35in 34.4mm
Cat. No. A7599
Cat. No. A7899
Ordering Information
Description
Tamper-Resistant Slim Series GFCI
with Audible Trip Alert
Rating
Cat. No.
Color
15A-125V Receptacle,
20A-125V Feed-Through
R02-A7599-0KW
001-A7599-00I
002-A7599-00W
006-A7599-00T
White
Ivory
White
Light Almond
20A-125V Receptacle,
20A-125V Feed-Through
R02-A7899-0KW
001-A7899-00I
002-A7899-00W
006-A7899-00T
White
Ivory
White
Light Almond
Leviton Manufacturing Co., Inc. World Headquarters
201 North Service Road, Melville, NY 11747-3138
Telephone: 1-800-323-8920 FAX: 1-800-832-9538
Tech Line (8:30AM-7:00PM E.T. Monday-Friday): 1-800-824-3005
Visit our Website at: www.leviton.com/gfci
© 2014 Leviton Manufacturing Co., Inc. All rights reserved.
All trademarks are the property of their respective owners.
G-9265/F14-dp