Tadiran Lithium Batteries

advertisement
Tadiran Lithium Batteries
Product Data
Catalogue
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
Figure 1: Upon request, Tadiran
designs, tests, and manufactures
customized battery packs.
2
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
Customized battery packs
The design and assembly
of battery packs require
special skills, expertise and
experience. Therefore it is not
recommended that the end
user attempt to self-assemble
battery packs. It is preferable that any battery using
lithium cells be fabricated by
Tadiran to ensure proper battery design and construction
(see figure 1). A full battery
assembly service is available
from Tadiran who can be contacted for further information.
If for any reason, this is not
possible, Tadiran can review
the pack design in confidence
to ensure that the design is
safe (in assembly and use)
and capable of meeting stated
performance requirements.
Overview Product Line
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
28
29
30
31
32
33
34
34
35
36
36
37
38
38
39
40
41
42
43
43
44
44
45
45
46
47
48
49
50
51
Size
SL-300 series: for standard use and stand-by
SL-350
/S /T /P /PR /PT
11 1 0350x 00
1/2AA
2 ⁄3AA
SL-361
/S /T /P /PR /PT
11 1 0361x 00
SL-360
/S /T /P /PR /PT
11 1 0360x 00
AA
SL-500 series: for extended temperature range
SL-550
/S /T /P /PR /PT
11 1 0550x 00
1/2AA
2 ⁄3AA
SL-561
/S /T /P /PR /PT
11 1 0561x 00
SL-560
/S /T /P /PR /PT
11 1 0560x 00
AA
SL-700 / SL-2700 series: for enhanced start
SL-750
/S /T /P /PR /PT
11 1 0750x 00
1/2AA
2 ⁄3AA
SL-761
/S /T /P /PR /PT
11 1 0761x 00
SL-760
/S /T /P /PR /PT
11 1 0760x 00
AA
SL-2770
/S /T /P
11 2 1770x 00
C
SL-2780
/S /T /P
11 2 1780x 00
D
SL-2790
/S /T
11 2 1790x 00
DD
SL-800 / SL-2800 series: XOL for extended operating life
1 ⁄10
TL-2450
/P (with insolation)
11 1 13763 02
C
1 ⁄10
TL-2450
/P (without insolation)
11 1 13763 22
C
1 ⁄10D
SL-889
Solder pins
11 1 18894 00
1 ⁄6D
SL-886
Solder pins
11 1 18864 00
SL-850
/S /T /P /PR /PT
11 1 0850x 00
1/2AA
2 ⁄3AA
SL-861
/S /T /P /PR /PT
11 1 0861x 00
SL-860
/S /T /P /PR /PT
11 1 0860x 00
AA
SL-2870
/S /T /P
11 2 1870x 00
C
SL-2880
/S /T /P
11 2 1880x 00
D
PulsesPlus TM Batteries
Model
Termination
Catalogue number
Nominal
voltage
Nominal
capacity
Nominal
current
Max. cont. discharge current
Temperature
range
Dimensions
(mm)
3.6 V
3.6 V
3.6 V
1.2 Ah
1.6 Ah
2.4 Ah
0.6 mA
1 mA
2 mA
6 mA
10 mA
20 mA
−55 ... +85 °C
−55 ... +85 °C
−55 ... +85 °C
Ø 14.5 x 25
Ø 14.5 x 33
Ø 14.5 x 50
3.6 V
3.6 V
3.6 V
0.9 Ah
1.1 Ah
1.8 Ah
0.6 mA
1 mA
2 mA
50 mA
75 mA
100 mA
−55 ... +130 °C
−55 ... +130 °C
−55 ... +130 °C
Ø 14.5 x 25
Ø 14.5 x 33
Ø 14.5 x 50
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
1.1 Ah
1.5 Ah
2.2 Ah
8.5 Ah
19 Ah
35 Ah
1 mA
1.3 mA
2 mA
3 mA
4 mA
10 mA
50 mA
75 mA
100 mA
230 mA
340 mA
450 mA
−55 ... +85 °C
−55 ... +85 °C
−55 ... +85 °C
−55 ... +85 °C
−55 ... +85 °C
−55 ... +85 °C
Ø 14.5 x 25
Ø 14.5 x 33
Ø 14.5 x 50
Ø 26 x 50
Ø 33 x 60
Ø 33 x 123
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
0.55 Ah
0.55 Ah
1 Ah
1.5 Ah
1.2 Ah
1.6 Ah
2.4 Ah
8.5 Ah
19 Ah
0.5 mA
0.5 mA
0.5 mA
0.5 mA
0.5 mA
0.5 mA
1 mA
3 mA
4 mA
5 mA
5 mA
10 mA
10 mA
20 mA
30 mA
60 mA
75 mA
100 mA
−55 ... +85 °C
−55 ... +85 °C
−55 ... +85 °C
−55 ... +85 °C
−55 ... +85 °C
−55 ... +85 °C
−55 ... +85 °C
−55 ... +85 °C
−55 ... +85 °C
Ø 24 x 5.6
Ø 24 x 5.6
Ø 33 x 6
Ø 33 x 10
Ø 14.5 x 25
Ø 14.5 x 33
Ø 14.5 x 50
Ø 26 x 50
Ø 33 x 60
Configuration
Primary cell
HLC
TLP-91111/A/SM
Flying leads
17 91111 101
AA
1550
TLP-91311/A/SM
Pressure contacts
17 91311 101
AA
1520
TLP-91311/A/ST
Solder tags
17 91311 102
AA
1520
TLP-92111/A/SM
Flying leads
17 92111 101
C
1550
TLP-92311/A/SM
Flying leads
17 92311 101
C
1520
TLP-93111/A/SM
Flying leads
17 93111 101
D
1550
TLP-93311/A/SM
Flying leads
17 93311 101
D
1520
TLP-96111/A/SM
Flying leads
17 96111 101
1/2AA
1550
TLP-96311/A/SM
Pressure contacts
17 96311 101
1/2AA
1520
TLP-96311/A/ST
Solder tags
17 96311 102
1/2AA
1520
2 ⁄3AA
TLP-97111/A/SM
Flying leads
17 97111 101
1550
2 ⁄3AA
TLP-97311/A/SM
Pressure contacts
17 97311 101
1520
2 ⁄3AA
TLP-97311/A/ST
Solder tags
17 97311 102
1520
Hybrid Layer Capacitors (HLC) for use in PulsesPlus TM Batteries
Model
Maximum
Maximum
Max. cont.
Max. pulse Maximum
charge
charging
discharge
discharge
capacity
voltage
current
current
current
(3.67 V)
HLC-1020
3.95 V
8 mA
0.25 A
0.75 A
12.5 mAh
HLC-1020L
3.95 V
6 mA
0.15 A
0.5 A
8 mAh
HLC-1520A
3.95 V
25 mA
0.5 A
2A
39 mAh
HLC-1530A
3.95 V
50 mA
0.75 A
3A
70 mAh
HLC-1550A
3.95 V
100 mA
2A
5A
155 mAh
Tadiran Lithium Metal Oxide (TLM) Batteries
Model
Nominal
Max. cont. disMax. pulse disMaximum
voltage
charge current
charge current
capacity
TLM-1520HP
4.0 V
1.25 A
3.5 A
135 mAh
TLM-1520HE
4.0 V
1.5 A
3.5 A
250 mAh
TLM-1530HP
4.0 V
2.25 A
6.5 A
240 mAh
TLM-1530HE
4.0 V
2.5 A
7A
450 mAh
TLM-1550HP
4.0 V
5A
15 A
550 mAh
TLM-1550HE
4.0 V
5A
15 A
1000 mAh
Tadiran Lithium Ion (TLI) Batteries – RECHARGEABLE
Model
Max. charge Max. charging
Max. cont. disMax. pulse discharge current
charge current
voltage
current
TLI-1020A
4.1 V
8 mA
0.16 A
0.4 A
TLI-1520A
4.1 V
25 mA
0.5 A
1.25 A
TLI-1530A
4.1 V
50 mA
1A
2.5 A
TLI-1550A
4.1 V
100 mA
2A
5A
Safety and Transport Regulations
1) complete
catalogue number depends on termination; see product page
2)
pulse duration 1 s to 3 V
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
3
Nominal
voltage
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
3.6 V
Nominal
capacity
2.40 Ah
2.40 Ah
2.40 Ah
8.50 Ah
8.50 Ah
19.0 Ah
19.0 Ah
1.2 Ah
1.2 Ah
1.2 Ah
1.6 Ah
1.6 Ah
1.6 Ah
Max. pulse
current2)
3A
1A
1A
3A
1A
3A
1A
3A
1A
1A
3A
1A
1A
Maximum
capacity
(3.9 V)
20 mAh
12.5 mAh
58 mAh
105 mAh
236 mAh
Discharge
end voltage
End
voltage
2.8 V
2.5 V
2.8 V
2.5 V
2.8 V
2.5 V
Cell
impedance
≤ 250 mΩ
≤ 300 mΩ
≤ 175 mΩ
≤ 160 mΩ
≤ 100 mΩ
≤ 80 mΩ
Capacity
retention3)
89 %
90 %
89 %
90 %
89 %
90 %
Dimensions
(mm)
Ø 15 x 20
Ø 15 x 20
Ø 15 x 27
Ø 15 x 27
Ø 15 x 50
Ø 15 x 50
Maximum
capacity
25 mAh
90 mAh
150 mAh
330 mAh
End
voltage
2.5 V
2.5 V
2.5 V
2.5 V
Cell
impedance
≤ 600 mΩ
≤ 250 mΩ
≤ 175 mΩ
≤ 100 mΩ
Dimensions
(mm)
Ø 10 x 20
Ø 15 x 20
Ø 15 x 27
Ø 15 x 50
3)
2.5 V
2.5 V
2.5 V
2.5 V
2.5 V
Cell
impedance
Dimensions
(mm)
55 x 32 x 16
Ø 16.5 x 75
Ø 16.5 x 75
55 x 44 x 28
Ø 29 x 67
64 x 50 x 35
Ø 34 x 78
55 x 32 x 16
Ø 16.5 x 50
Ø 16.5 x 50
55 x 32 x 16
Ø 16.5 x 58
Ø 16.5 x 58
≤ 400 mΩ
≤ 600 mΩ
≤ 250 mΩ
≤ 140 mΩ
≤ 100 mΩ
Dimensions
(mm)
Ø 10 x 20
Ø 10 x 20
Ø 15 x 20
Ø 15 x 27
Ø 15 x 50
after 10 years of storage at RT
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
Page Contents
4 About Tadiran
5 Lithium Thionyl Chloride (LTC) Batteries
Model
Terminations
Catalogue number1)
About Tadiran
Tadiran Batteries GmbH
Tadiran Batteries GmbH is one
of the leading manufacturers
of primary (non rechargeable)
lithium batteries in Europe.
The company was founded
as a Joint Venture between
Tadiran and Sonnenschein in
1984 and – under the name
of Sonnenschein Lithium
– has successfully served
the market for more than
30 years.
Together with its parent company Tadiran Batteries Ltd.,
the company is continuously
improving its performance
with regard to products,
highest quality and customer
service.
Tadiran Batteries Ltd. is fully
owned by Saft groupe S.A.
(Euronext: SAFT).
The main focus of the company is to achieve a maximum
customer satisfaction. Thus
the guide line is to be the
best in design-in, in full technical support and logistics.
The company is committed to
the world class philosophy.
The management system is
certified to ISO 9001 (Quality) and – since 1999 – to ISO
14001 (Environment).
The PulsesPlus TM technology,
providing high current pulses
in combination with high
energy, has been successfully
introduced into the market
and plays a significant role
especially for long distance
communication (e.g. GSM)
modules.
The TLM technology has been
developed for applications requiring high power discharge
after a long storage time, e.g.
as a back up battery for emergency call devices in automotive telematic systems.
The RECHARGEABLE TLI
series is specifically designed
for long-term use in harsh
environments and represents an important breakthrough in lithium-ion battery
technology.
Customer benefits
Tadiran has focused its ongoing efforts on promoting
the understanding and further
development of lithium batteries. This determination offers to the customer a number
of decisive benefits such as:
Access to over 40 years of
experience in research and
development, production
and marketing
Adaptability and reliability
in meeting rapidly evolving
customer needs
Detailed technical support
in terms of design and application – before, during
and after the purchase
Highly qualified experts
available for support
on short notice
Customized production
of single- and multi-cell
batteries to meet specific
requirements
Reliable delivery, secured
by contractual agreements
and second sourcing.
For successful use of a
battery, the co-operation
between the supplier and the
customer must commence at
the earliest possible point:
at times it is simply more
economical to design a circuit
for the characteristics of the
best suitable energy supply,
rather than having to forgo its
advantages because it is too
late for changes.
Environment
The European Battery Directive 2006/66/EC restricts
the use of certain hazardous
substances in batteries and
establishes rules for the collection, treatment, recycling
and disposal of waste batteries and accumulators. It
is transposed individually in
each EU member state.
The following information is
important for end users of
batteries:
Batteries are marked with
the crossed-out wheeled bin
symbol.
The symbol reminds end users
that batteries must not be
disposed as municipal waste,
but collected separately. Used
batteries can be returned at
the point of sale at no charge.
The reason for these regulations is that there are a number of environmental concerns
which arise when dealing with
the waste management of
batteries and accumulators.
These relate for the most part
to the metals contained in
these batteries. Mercury, lead
and cadmium are by far the
most problematic substances
in the battery waste stream.
Other metals commonly used
in batteries, such as zinc, copper, manganese, lithium and
nickel, may also constitute
environmental hazards.
However, the regulations
apply to all batteries and
not just to hazardous ones
because all batteries contain
substances which are more or
less harmful to the environment and because experience
with previous regulations
showed that ‘all battery’ collection schemes are more efficient than separate schemes
for certain types of portable
batteries.
Batteries should be recycled
because battery recycling
helps to save resources by
allowing for the recovery
of valuable metals such as
nickel, cobalt and silver and
requires less energy consumption. For example, using
recycled cadmium and nickel
requires respectively 46 %
and 75 % less primary energy
than the extraction and refining of virgin metals.
This information is based on
the ‘Q&A on the Batteries
Directive 2006/66/EC’ document and was downloaded
from the European Commission website.
A Technical Notice is available
upon request with details on
the disposal service offered by
Tadiran.
PDC16Eng
Tadiran Batteries GmbH employs approx. 100 people and
has its production facilities in
Büdingen, close to Frankfurt,
Germany.
The company is a leader in
the development of lithium
batteries for industrial use.
Its Lithium Thionyl Chloride
(LTC) technology is well established for more than 35 years.
Tadiran LTC batteries are
suitable where a 3.6 Volt high
energy primary battery is required for up to 25 years and
more stand alone operation.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
4
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
Lithium Thionyl Chloride (LTC) Batteries
Introduction
Battery characteristics
The major advantages of the
Tadiran lithium battery are:
High cell voltage
The battery has a nominal
voltage of 3.6 Volts, which is
considerably higher than any
other commercially available
primary cell.
Wide temperature range
The batteries are capable
of operating in a wide temperature range normally from
−55 °C to +85 °C. One series,
however, has an extended
temperature range of up to
+130 °C.
High energy density
The electrochemical system
offers the highest energy density of any available primary
battery: up to ~650 Wh / kg
and ~1280 Wh / dm3 (see
figure 2).
Superior shelf life
and reliability
The Tadiran lithium battery has
an outstandingly long shelf life.
Tests have shown that storage
for ten years at room temperature results in a capacity loss of
less than 1 % per year.
Tadiran lithium batteries are
also extremely reliable. Failure rates in memory back-up
applications were found to be
below 200 fit (fit: Failures in
Time. 1 fit = 1 failure in 109
component hours).
Figure 1: Cross sectional view of a ½AA size cell (bobbin-design)
Safe design
The battery’s design has a
major influence on its safety
characteristics (see figure 1).
In the bobbin version, the
cathode is cylindrical in
shape. The anode is swaged
against the inner wall of
the battery case. This offers
several advantages in terms
of safety. In the event of an
unintentional short-circuit,
the discharge currents do
not become very strong. The
heat generated, primarily at
the contact surface between
the anode and cathode, can
easily be channelled to the
outside. This design leads to
a safe battery that needs no
additional rupture vent.
In the flat battery versions,
the anode is pressed onto the
bottom of the case, and the
cathode is disk-shaped. Flat
batteries are wider than they
are high. They are just as safe
as the bobbin type batteries.
Hermetically sealed case
The hermetically sealed case
is essential for the long shelf
life and inherent safety of the
devices in which the batteries
are used. The cover is welded
to the can. A glass-to-metal
seal is used to insulate the
positive terminal.
The chemical reaction
The battery consists of a lithium (Li) anode, a carbon (C)
cathode, and a non-aqueous
electrolyte (a solution of lithium tetra-chloroaluminate in
thionyl chloride). This solution
performs a dual task: as the
electrolyte for ion transport,
and as an active depolarizer.
The Teflon™-bonded carbon
cathode serves as a catalyst
for cathodic reduction.
The generally accepted reaction
mechanisms are as follows:
Anodic reaction:
4 Li → 4 Li+ + 4 e−
Cathodic reaction:
2 SOCl2 + 4 e− →
SO2 + S + 4 Cl−
Overall reaction:
4 Li + 2 SOCl2 →
S + 4 LiCl + SO2
Most of the sulphur dioxide
generated during discharge
dissolves in the electrolyte,
preventing pressure build-up
within the battery.
Long-term behaviour
The long shelf life of the
Tadiran lithium batteries is a
result of the fact that a thin
protective layer of LiCl forms
on the anode as soon as the
lithium first comes into contact with the electrolyte. This
layer prevents further reaction
or loss of capacity on stand.
The problem of anode corrosion, as occurs in aqueous
systems, is thus eliminated.
On the other hand, the protective layer on the anode may
cause a delay in the voltage
build-up if relatively high
loads are applied, or after
extended storage at elevated
temperatures. This voltage
delay is not experienced at
all in microampere applications, such as in typical CMOS
circuits.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
5
Features and
attributes
of the various series
SL-300 series
Keywords: standard use and
stand-by
Excellent shelf life
(10 years)
Extremely low
self-discharge (1 %
or less per year)
Suited for long-term
use with low current
For operation at low current
levels with long stands
Intermittent discharge
with medium current level
provided the average
is not below the active
current level (2 µA / cm²
anode surface area)
Temperature range from
−55 °C to +85 °C
Intermittent discharge at
medium current levels
Best results if used
after no more than
3 years of storage
Otherwise like the
SL-300 series
SL-2700 series (iXtra)
Keywords: for fast voltage recovery after long term storage
and/or use
Higher voltage under
pulse load even with low
background currents
Improved voltage delay
behaviour at ambient and
elevated temperatures
Fast voltage recovery
after long term storage
More capacity
Higher discharge rate
No orientation effect
SL-500 series
Keywords: extended temperature range
Extension of temperature
range up to +130 °C
Somewhat smaller capacity
Otherwise like the
SL-700 series
SL-800/2800 series (XOL)
Keywords: for eXtended
operation life
More capacity
Extra low self discharge
Extra low passivation
during long term use
SL-700 series
Keywords: for enhanced start
Major improvement of
voltage delay (TMV) at
the start of discharge at
medium current levels
4.0
1
3.5
2
3.0
3
2.5
4
2.0
5
1.5
6
1.0
0.5
0.0
0
100
200
Ah / dm3
300
400
Figure 2:
Comparison of different battery systems. The curves represent typical
best values of commercial cylindrical cells when discharged at +25 °C
at the 1000 hour rate. The area under the curves corresponds to the
energy density listed below.
1 Li/SOCl2 1280 Wh / dm3
2 Li/SO2 430 Wh / dm3
3 Li/CFx
550 Wh / dm3
4 Li/MnO2 580 Wh / dm3
5 Li/FeS2 450 Wh / dm3
6 Alkaline 280 Wh / dm3
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
The Tadiran lithium battery
is a component that can be
permanently connected to a
circuit and, in many cases, will
last the entire lifetime of the
equipment.
Positive terminal
Plastic cover
Welding seam
Cell cover
Glass-to-metal seal
Insulator
Current collector
Lithium anode
Cathode
Separator
Insulating sleeve
Cell can
Negative terminal
Voltage / V
The Lithium Thionyl
Chloride (LTC) battery
The Tadiran lithium thionyl
chloride inorganic electrolyte
battery is a power source that
is suited to the requirements
of the new generation in
microelectronics. For example,
CMOS memories as well as
utility meters require a lightweight power source to provide a safe and reliable performance over a wide range of
environmental conditions, for
long periods of time.
LTC Batteries
SL-350
Size: ½AA
›› Standard use and stand-by
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
1.2 Ah
0.6 mA
6 mA
6 cm2
0.35 g
9.6 g
4 cm3
−55 °C ... +85 °C
Typical Discharge Curves at +25 °C
Voltage / V
3.0
1
2.5
2.0
1.0
0.5
1.2
3
4
5
1: 560 Ω
~6 mA
2: 1.8 kΩ
~2 mA
3: 5.6 kΩ ~0.6 mA
4: 18 kΩ ~0.2 mA
5: 56 kΩ ~0.06 mA
6: 180 kΩ ~0.02 mA
7: 560 kΩ ~0.006 mA
1.5
0.0
2
0.1
1
10
102
Time / h
103
6
7
0.90 Ah
1.10 Ah
1.20 Ah
1.15 Ah
1.05 Ah
0.95 Ah
0.85 Ah
104
105
Available Capacity
SL-350/S
+0.2
−0.3
25.2–1.2
0.7±0.3
Ø 4.2
SL-350/T
Capacity to 2 Volts / Ah
4
1.0
3
2
0.8
5
1
0.6
1:
2:
3:
4:
5:
0.4
0.2
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
0.0
0.01
7±0.5
0.1
1
10
Current / mA
3.17
100
1000
0.15 thick
SL-350/P
Ø 14.7
3.8
5
4
3.4
Voltage / V
Ø 0.8
45
Operating Voltage
3.6
Ø 0.8
–1.2
45
3
3.2
2
3.0
2.8
1
6 mA
1:
2 mA
2:
3: 0.6 mA
4: 0.2 mA
5: 0.02 mA
2.6
SL-350/PR
SL-350/PT
2.4
10 25 40 55
Temperature / °C
70
85 100
3.5
4+0.5
1–0.1
1–0.1
0.2 thick
0.2 thick
Available Terminations
Catalogue No.
SL-350/S
SL-350/T
SL-350/P
SL-350/PR
SL-350/PT
11 1 03501 00
11 1 03502 00
11 1 03503 00
11 1 03506 00
11 1 03508 00
Standard
Tags
Pins
Pins radial
Polarized tags
10.16
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
PDC16Eng
3.5
4+0.5
−50 −35 −20 −5
6
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries
SL-361
Size: 2⁄3AA
›› Standard use and stand-by
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
1.6 Ah
1 mA
10 mA
9 cm2
0.5 g
12.5 g
5.2 cm3
−55 °C ... +85 °C
Typical Discharge Curves at +25 °C
Voltage / V
3.0
1
2.5
2.0
1:
2:
3:
4:
5:
6:
7:
1.5
1.0
0.5
0.0
1.6
0.1
+0.2
−0.3
+
0.7±0.3
Ø 4.2
Capacity to 2 Volts / Ah
SL-361/T
33.5−1.5
3.17
102
Time / h
103
7
1.00 Ah
1.35 Ah
1.60 Ah
1.60 Ah
1.50 Ah
1.35 Ah
1.10 Ah
104
105
2
0.8
0.6
1:
2:
3:
4:
5:
0.4
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
0.1
1
10
Current / mA
100
1000
0.15 thick
3.8
5
3.4
Voltage / V
45
Operating Voltage
3.6
Ø 0.8
Ø 0.8
SL-361/P
Ø 14.7−1.2
330 Ω ~10 mA
1.0 kΩ
~3 mA
3.3 kΩ
~1 mA
10 kΩ ~0.3 mA
33 kΩ ~0.1 mA
100 kΩ ~0.03 mA
330 kΩ ~0.01 mA
6
1
0.0
0.01
7
5
5
0.2
±0.5
10
4
4
3
1.2
1.0
1
3
Available Capacity
1.4
SL-361/S
2
45
3.2
3.0
2.8
6
4
3
2
1: 10 mA
2:
3 mA
3:
1 mA
4: 0.3 mA
5: 0.1 mA
6: 0.01 mA
1
2.6
SL-361/PR
SL-361/PT
2.4
10 25 40 55
Temperature / °C
70
85 100
3.5
4+0.5
1−0.1
1−0.1
0.2 thick
0.2 thick
Available Terminations
Catalogue No.
SL-361/S
SL-361/T
SL-361/P
SL-361/PR
SL-361/PT
11 1 03611 00
11 1 03612 00
11 1 03613 00
11 1 03616 00
11 1 03618 00
Standard
Tags
Pins
Pins radial
Polarized tags
10.16
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
PDC16Eng
3.5
4+0.5
−50 −35 −20 −5
7
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries
SL-360
Size: AA
›› Standard use and stand-by
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
2.4 Ah
2 mA
20 mA
14 cm2
0.65 g
18 g
8 cm3
−55 °C ... +85 °C
Voltage / V
3.0
1
2.5
2.0
1.0
0.5
0.0
SL-360/T
+0.2
−0.3
0.7±0.3
Ø 4.2
Capacity to 2 Volts / Ah
SL-360/S
50.5−1.5
0.1
3
1
10
3
2.0
5
6
102
Time / h
103
7
1.5 Ah
2.1 Ah
2.4 Ah
2.4 Ah
2.3 Ah
2.1 Ah
1.9 Ah
104
105
4
2
5
1
1.5
1.0
1:
2:
3:
4:
5:
0.5
0.1
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
1
10
Current / mA
3.17
100
1000
0.15 thick
45
Operating Voltage
5
3.6
4
3.4
Voltage / V
Ø 14.7–1.2
3.8
Ø 0.8
Ø 0.8
SL-360/P
45
3
3.2
3.0
2.8
2
1
1: 20 mA
2:
6 mA
3:
2 mA
4: 0.2 mA
5: 0.02 mA
2.6
SL-360/PR
SL-360/PT
2.4
10 25 40 55
Temperature / °C
70
85 100
3.5
4+0,5
1−0.1
1−0.1
0.2 thick
0.2 thick
Available Terminations
Catalogue No.
SL-360/S
SL-360/T
SL-360/P
SL-360/PR
SL-360/PT
11 1 03601 00
11 1 03602 00
11 1 03603 00
11 1 03606 00
11 1 03608 00
Standard
Tags
Pins
Pins radial
Polarized tags
10.16
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
PDC16Eng
4+0,5
−50 −35 −20 −5
3.5
4
Available Capacity
0.0
0.01
7±0.5
2
1: 180 Ω ~20 mA
2: 560 Ω
~6 mA
3: 1.8 kΩ
~2 mA
4: 5.6 kΩ ~0.6 mA
5: 18 kΩ ~0.2 mA
6: 56 kΩ ~0.06 mA
7: 180 kΩ ~0.02 mA
1.5
2.5
+
Typical Discharge Curves at +25 °C
8
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries
›› Extended temperature range
›› iXtra – long term high performance
Size: 1/2AA
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
0.9 Ah
0.6 mA
50 mA
100 mA
6 cm2
0.35 g
9.6 g
4 cm3
−55 °C ... +130 °C
Voltage / V
3.0
1
2.5
4
2.0
1.5
2
3
2
0.5
0 2 4 6
0.0
0.1
SL-550/T
25.2–1.2
0.7±0.3
+0.2
−0.3
Capacity to 2 Volts / Ah
SL-550/S
6 7
3
4
1: 180 Ω
2: 560 Ω
3: 1.8 kΩ
4: 5.6 kΩ
5: 18 kΩ
6: 56 kΩ
7: 180 kΩ
s 10
1
10
102
Time / h
103
5
6
~20 mA
~6 mA
~2 mA
~0.6 mA
~0.2 mA
~0.06 mA
~0.02 mA
7
0.50 Ah
0.80 Ah
0.85 Ah
0.90 Ah
0.85 Ah
0.80 Ah
0.70 Ah
104
105
Available Capacity
1.0
0.8
5
4
0.6
3
2
1 1: +120 °C 6
2: +80 °C
3: +50 °C
4: +25 °C
5:
0 °C
6: –30 °C
0.4
0.2
0.0
0.01
7±0.5
5
34
2
1
1.0
1.2
Ø 4.2
Typical Discharge Curves at +25 °C
Volts
SL-550
0.1
1
10
Current / mA
3.17
100
1000
0.15 thick
SL-550/P
Ø 14.7
3.8
5
4
3.4
Voltage / V
Ø 0.8
45
Operating Voltage
3.6
Ø 0.8
–1.2
45
3
3.2
2
3.0
1
2.8
1:
6 mA
2:
2 mA
3:
0.6 mA
4: 0.06 mA
5: 0.006 mA
2.6
85
10
0
11
5
13
0
14
5
70
55
40
25
0
−5
10
−3
−5
Temperature / °C
3.5
4+0.5
1–0.1
1–0.1
0.2 thick
0.2 thick
Available Terminations
Catalogue No.
SL-550/S
SL-550/T
SL-550/P
SL-550/PR
SL-550/PT
11 1 05501 00
11 1 05502 00
11 1 05503 00
11 1 05506 00
11 1 05508 00
Standard
Tags
Pins
Pins radial
Polarized tags
10.16
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 150 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
PDC16Eng
3.5
4+0.5
5
2.4
−2
SL-550/PT
0
SL-550/PR
9
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries
SL-561
›› Extended temperature range
›› iXtra – long term high performance
Size: 2⁄3AA
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
1.1 Ah
1 mA
75 mA
150 mA
9 cm2
0.5 g
12.5 g
5.2 cm3
−55 °C ... +130 °C
Typical Discharge Curves at +25 °C
1
2.5
4
2.0
Volts
Voltage / V
3.0
1.5
3
2
7
56
34
2
0.5
0 2 4 6
0.0
0.1
s 10
1
3
4
5
6
1: 100 Ω ~30 mA
2: 330 Ω ~10 mA
3:
1 kΩ
~3 mA
4: 3.3 kΩ
~1 mA
5: 10 kΩ ~0.3 mA
6: 33 kΩ ~0.1 mA
7: 100 kΩ ~0.03 mA
1
1.0
2
10
102
Time / h
103
7
0.60 Ah
0.80 Ah
1.00 Ah
1.10 Ah
1.10 Ah
1.00 Ah
0.85 Ah
104
105
Available Capacity
1.6
SL-561/S
SL-561/T
+0.2
−0.3
+
0.7±0.3
Ø 4.2
1.2
1.0
5
0.8
4
1:
2:
3:
4:
5:
2
0.4
0.2
3.17
120
80
50
25
–30
0.1
°C
°C
°C
°C
°C
1
10
Current / mA
100
1000
0.15 thick
3.8
5
4
3.4
Voltage / V
45
Operating Voltage
3.6
Ø 0.8
Ø 0.8
SL-561/P
Ø 14.7−1.2
1
3
0.6
0.0
0 .0 1
7
±0.5
33.5−1.5
Capacity to 2 Volts / Ah
1.4
45
3
3.2
2
3.0
1
2.8
1:
2:
3:
4:
5:
2.6
85
10
0
11
5
13
0
14
5
70
55
40
25
0
−5
10
−3
−5
Temperature / °C
3.5
4+0.5
1−0.1
1−0.1
0.2 thick
0.2 thick
Available Terminations
Catalogue No.
SL-561/S
SL-561/T
SL-561/P
SL-561/PR
SL-561/PT
11 1 05611 00
11 1 05612 00
11 1 05613 00
11 1 05616 00
11 1 05618 00
Standard
Tags
Pins
Pins radial
Polarized tags
10.16
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 150 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
10
PDC16Eng
3.5
4+0.5
5
2.4
−2
SL-561/PT
0
SL-561/PR
10 mA
3 mA
1 mA
0.1 mA
0.01 mA
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries
›› Extended temperature range
›› iXtra – long term high performance
Size: AA
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
1.8 Ah
2 mA
100 mA
200 mA
14 cm2
0.65 g
18 g
8 cm3
−55 °C ... +130 °C
Typical Discharge Curves at +25 °C
Voltage / V
3.0
1
2.5
4
2.0
1.5
3
2
7
56
34
Volts
SL-560
2
2
0.5
0 2 4 6
0.0
0.1
s 10
1
4
5
6
1:
56 Ω ~60 mA
2: 180 Ω ~20 mA
3: 560 Ω
~6 mA
4: 1.8 kΩ
~2 mA
5: 5.6 kΩ ~0.6 mA
6: 18 kΩ ~0.2 mA
7: 56 kΩ ~0.06 mA
1
1.0
3
10
102
Time / h
103
7
1.40 Ah
1.60 Ah
1.70 Ah
1.80 Ah
1.70 Ah
1.60 Ah
1.40 Ah
104
105
Available Capacity
SL-560/S
SL-560/T
+0.2
−0.3
+
0.7±0.3
Ø 4.2
Capacity to 2 Volts / Ah
2.5
2.0
5
1.5
3
1.0
1
2
1:
2:
3:
4:
5:
0.5
0
0 .0 1
7±0.5
50.5−1.5
4
3.17
0.1
120
80
50
25
–30
°C
°C
°C
°C
°C
1
10
Current / mA
100
0.15 thick
45
Operating Voltage
5
3.6
4
3.4
Voltage / V
Ø 14.7–1.2
3.8
Ø 0.8
Ø 0.8
SL-560/P
45
3
3.2
2
3.0
1
2.8
1:
2:
3:
4:
5:
2.6
85
10
0
11
5
13
0
14
5
70
55
40
25
10
0
−5
−3
−5
20 mA
6 mA
2 mA
0.2 mA
0.02 mA
Temperature / °C
3.5
4+0,5
1−0.1
1−0.1
0.2 thick
0.2 thick
Available Terminations
Catalogue No.
SL-560/S
SL-560/T
SL-560/P
SL-560/PR
SL-560/PT
11 1 05601 00
11 1 05602 00
11 1 05603 00
11 1 05606 00
11 1 05608 00
Standard
Tags
Pins
Pins radial
Polarized tags
10.16
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 150 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
11
PDC16Eng
4+0,5
5
2.4
−2
SL-560/PT
0
SL-560/PR
3.5
1000
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries
Size: ½AA
›› iXtra – long term high performance
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
1.1 Ah
1 mA
50 mA
100 mA
6 cm2
0.35 g
9.6 g
4 cm3
−55 °C ... +85 °C
Voltage / V
3.0
1
2.5
4
2.0
1.5
2
3
2
0.5
25.2–1.2
0.7±0.3
+0.2
−0.3
Capacity to 2 Volts / Ah
SL-750/T
1
3
4
5
6
10
103
102
Time / h
7
0.5 Ah
1.0 Ah
1.1 Ah
1.1 Ah
1.1 Ah
1.05 Ah
0.95 Ah
104
105
Available Capacity
4
1.0
3
0.8
2
0.6
1
0.4
1:
2:
3:
4:
0.2
+72 °C
+55 °C
+25 °C
−30 °C
0.0
0.01
7±0.5
2
1: 180 Ω ~20 mA
2: 560 Ω
~6 mA
3: 1.8 kΩ
~2 mA
4: 5.6 kΩ ~0.6 mA
5: 18 kΩ ~0.2 mA
6: 56 kΩ ~0.06 mA
7: 180 kΩ ~0.02 mA
0 2 4 6 s 10
0.0
0.1
SL-750/S
7
5 6
34
1
1.0
1.2
Ø 4.2
Typical Discharge Curves at +25 °C
Volts
SL-750
0.1
1
10
Current / mA
3.17
100
1000
0.15 thick
3.8
5
3.6
Ø 0.8
4
3.4
Voltage / V
Ø 0.8
45
Operating Voltage
45
3
3.2
2
3.0
1
2.8
1:
6 mA
2:
2 mA
3:
0.6 mA
4: 0.06 mA
5: 0.006 mA
2.6
SL-750/PR
2.4
SL-750/PT
3.5
4+0.5
3.5
4+0.5
−50 −35 −20 −5
3.8
0.2 thick
0.2 thick
Available Terminations
Catalogue No.
SL-750/S
SL-750/T
SL-750/P
SL-750/PR
SL-750/PT
11 1 07501 00
11 1 07502 00
11 1 07503 00
11 1 07506 00
11 1 07508 00
Standard
Tags
Pins
Pins radial
Polarized tags
10.16
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
12
Basic current (bc)
5 µA
None
3.4
Voltage / V
1–0.1
70
85 100
Voltage Response at +25 °C, Pulse: 10 mA
3.6
1–0.1
10 25 40 55
Temperature / °C
1
3.2
1
2
4
4
10 µA
3
6
5
1
6
2
3.0
2.8
2.6
1: after 1 year at bc
2: after 2 years at bc
3: after 4 years at bc
2.4
0
0.1
0.2
0
Time / s
4: after 5 years at bc
5: after 7 years at bc
6: after 10 years at bc
0.1
0
0.1
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
SL-750/P
Ø 14.7
–1.2
LTC Batteries
Size: 2⁄3AA
›› iXtra – long term high performance
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
1.5 Ah
1.3 mA
75 mA
150 mA
9 cm2
0.5 g
12.5 g
5.2 cm3
−55 °C ... +85 °C
Typical Discharge Curves at +25 °C
Voltage / V
3.0
1
2.5
4
2.0
Volts
SL-761
1.5
3
2
0.5
+0.2
0.7±0.3
Ø 4.2−0.3
Capacity to 2 Volts / Ah
SL-761/T
33.5−1.5
3.17
6
10
102
Time / h
103
7
0.80 Ah
1.35 Ah
1.50 Ah
1.50 Ah
1.50 Ah
1.45 Ah
1.30 Ah
104
105
3
1.2
1.0
0.8
2
0.6
1
0.4
1:
2:
3:
4:
+72 °C
+55 °C
+25 °C
−30 °C
0.0
0.01
7
5
4
0.2
±0.5
4
1: 100 Ω ~30 mA
2: 330 Ω ~10 mA
3: 1.0 kΩ
~3 mA
4: 3.3 kΩ
~1 mA
5: 10 kΩ ~0.3 mA
6: 33 kΩ ~0.1 mA
7: 100 kΩ ~0.03 mA
s 10
1
3
Available Capacity
1.4
0.1
1
10
Current / mA
100
1000
0.15 thick
3.8
5
4
3.4
45
3
3.2
2
3.0
1
2.8
1: 10 mA
2:
3 mA
3:
1 mA
4: 0.1 mA
5: 0.01 mA
2.6
SL-761/PR
2.4
SL-761/PT
3.5
4+0.5
3.5
4+0.5
−50 −35 −20 −5
3.8
1
1
−0.1
−0.1
Available Terminations
Catalogue No.
SL-761/S
SL-761/T
SL-761/P
SL-761/PR
SL-761/PT
11 1 07611 00
11 1 07612 00
11 1 07613 00
11 1 07616 00
11 1 07618 00
Standard
Tags
Pins
Pins radial
Polarized tags
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
13
Basic current (bc)
7.5 µA
None
3.4
0.2 thick
Voltage / V
0.2 thick
70
85 100
Voltage Response at +25 °C, Pulse: 15 mA
3.6
10.16
10 25 40 55
Temperature / °C
1
3.2
1
2
4
4
15 µA
4
6
5
1
6
2
3.0
2.8
2.6
1: after 1 year at bc
2: after 2 years at bc
2.4
0
0.1
0.2
4: after 5 years at bc
5: after 7 years at bc
6: after 10 years at bc
0
Time / s
0.1
0
0.1
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
Voltage / V
45
Operating Voltage
3.6
Ø 0.8
Ø 0.8
SL-761/P
Ø 14.7−1.2
0 2 4 6
0.0
0.1
SL-761/S
7
56
34
1
1.0
1.6
+
2
2
LTC Batteries
Size: AA
›› iXtra – long term high performance
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
2.2 Ah
2 mA
100 mA
200 mA
14 cm2
0.65 g
18 g
8 cm3
−55 °C ... +85 °C
Voltage / V
3.0
1
2.5
4
2.0
1.5
2
3
2
0.5
0.7±0.3
Ø 4.2
Capacity to 2 Volts / Ah
SL-760/T
+0.2
−0.3
50.5−1.5
1
3
4
5
7
1:
56 Ω ~60 mA
2: 180 Ω ~20 mA
3: 560 Ω
~6 mA
4: 1.8 kΩ
~2 mA
5: 5.6 kΩ ~0.6 mA
6: 18 kΩ ~0.2 mA
7: 56 kΩ ~0.06 mA
10
102
Time / h
103
1.4 Ah
1.8 Ah
2.1 Ah
2.2 Ah
2.2 Ah
2.2 Ah
2.0 Ah
104
105
4
3
2.0
1.5
2
1.0
1
1:
2:
3:
4:
0.5
0.1
+72 °C
+55 °C
+25 °C
−30 °C
1
10
Current / mA
3.17
100
1000
0.15 thick
5
4
3.4
45
3
3.2
2
3.0
1
2.8
1: 20 mA
2:
6 mA
3:
2 mA
4: 0.2 mA
5: 0.02 mA
2.6
SL-760/PR
2.4
SL-760/PT
3.5
4+0,5
4+0,5
−50 −35 −20 −5
3.8
1
1
−0.1
−0.1
Available Terminations
Catalogue No.
SL-760/S
SL-760/T
SL-760/P
SL-760/PR
SL-760/PT
11 1 07601 00
11 1 07602 00
11 1 07603 00
11 1 07606 00
11 1 07608 00
Standard
Tags
Pins
Pins radial
Polarized tags
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
14
85 100
Basic current (bc)
10 µA
None
3.4
0.2 thick
Voltage / V
0.2 thick
70
Voltage Response at +25 °C, Pulse: 20 mA
3.6
10.16
10 25 40 55
Temperature / °C
1
3.2
1
2
4
4
20 µA
4
6
5
1
6
2
3.0
2.8
2.6
1: after 1 years at bc
2: after 2 years at bc
2.4
0
0.1
0.2
4: after 5 years at bc
5: after 7 years at bc
6: after 10 years at bc
0
Time / s
0.1
0
0.1
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
45
Operating Voltage
3.6
Voltage / V
Ø 14.7–1.2
3.8
Ø 0.8
Ø 0.8
SL-760/P
3.5
6
Available Capacity
0.0
0.01
7±0.5
7
56
0 2 4 6 s 10
0.0
0.1
SL-760/S
34
2
1
1.0
2.5
+
Typical Discharge Curves at +25 °C
Volts
SL-760
LTC Batteries
Size: C
›› iXtra – long term high performance
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
8.5 Ah
3 mA
230 mA
400 mA
30 cm2
2.5 g
49.5 g
26 cm3
−55 °C ... +85 °C
Typical Discharge Curves at +25 °C
Voltage / V
3.0
1
2.5
4
2.0
Volts
1.5
2
3
2
0.5
0 2 4 6
0.0
0.1
SL-2770/T
+0.2
−0.3
0.7±0.3
Ø 4.2
Capacity to 2 Volts / Ah
SL-2770/S
50.0−2
0.15 thick
6
Voltage / V
SL-2770/S
SL-2770/T
SL-2770/P
11 2 17701 00
11 2 17702 00
11 2 17703 00
Standard
Tags
Pins
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
15
104
105
5
1
1:
2:
3:
4:
5:
2
0.1
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
1
10
Current / mA
100
1000
Operating Voltage
7
6
5
4
3.2
3.0
3
2.8
2
2.6
1
1:
2:
3:
4:
5:
6:
7:
2.4
Voltage / V
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
103
4
Ø 0.8
Ø 0.8
Catalogue No.
7
33 Ω ~100 mA 2.2 Ah
100 Ω ~30 mA 5.8 Ah
330 Ω ~10 mA 7.9 Ah
1.0 kΩ
~3 mA 8.5 Ah
3.3 kΩ
~1 mA 8.4 Ah
10 kΩ ~0.3 mA 7.8 Ah
33 kΩ ~0.1 mA 6.9 Ah
102
Time / h
2
4
3.8
Available Terminations
6
3
−50 −35 −20 −5
45
5
Available Capacity
3.4
SL-2770/P
45
4
3.6
3.17
Ø 26.2−1
10
8
3.8
+1
3
1:
2:
3:
4:
5:
6:
7:
s 10
1
0
0.01
16−2
6 7
1
1.0
10
5
34
2
10 25 40 55
Temperature / °C
60 mA
30 mA
10 mA
3 mA
1 mA
0.3 mA
0.1 mA
70
85 100
Voltage Response at +25 °C, Pulse: 40 mA
3.6
None
Basic current (bc)
25 µA
3.4
1
1
45 µA
2
1
2
3.2
2
3
3.0
4
2.8
3
3
2.6
1: after 2 years at bc
2: after 5 years at bc
2.4
0
0.1
0.2
3: after 8 years at bc
4: after 10 years at bc
0
Time / s
0.1
0
0.1
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
SL-2770
LTC Batteries
Size: D
›› iXtra – long term high performance
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
19 Ah
4 mA
340 mA
600 mA
45 cm2
5g
93 g
51 cm3
−55 °C ... +85 °C
Typical Discharge Curves at +25 °C
Voltage / V
3.0
1
2.5
4
2.0
Volts
SL-2780
1.5
2
3
2
0.5
0 2 4 6
0.0
0.1
s 10
1
3
1:
2:
3:
4:
5:
6:
7:
1
1.0
20
6 7
5
34
2
10
4
5
6
7
33 Ω ~100 mA 9.0 Ah
56 Ω ~60 mA 13.1 Ah
180 Ω ~20 mA 16.9 Ah
560 Ω
~6 mA 18.7 Ah
1.8 kΩ
~2 mA 18.6 Ah
5.6 kΩ ~0.6 mA 17.2 Ah
18 kΩ ~0.2 mA 15.4 Ah
102
Time / h
103
104
105
Available Capacity
SL-2780/T
+0.2
−0.3
Ø 4.2
0.7±0.3
+
15
10
1
1:
2:
3:
4:
5:
5
0
0.01
3.8
61.5−2
+1
12−2
5
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
0.1
1
10
Current / mA
100
Operating Voltage
3.4
Voltage / V
7 6
5 4
3.2
3
3.0
2
1: 100 mA
2: 60 mA
3: 20 mA
4:
6 mA
5:
2 mA
6: 0.6 mA
7: 0.2 mA
1
2.8
2.6
Ø 32.9−0.7
SL-2780/P
2.4
Ø 0.8
Ø 0.8
−50 −35 −20 −5
Available Terminations
Catalogue No.
SL-2780/S
SL-2780/T
SL-2780/P
11 2 17801 00
11 2 17802 00
11 2 17803 00
Standard
Tags
Pins
Voltage / V
3.8
45
45
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
16
1000
3.6
0.15 thick
3.17
4
2
10 25 40 55
Temperature / °C
70
85 100
Voltage Response at +25 °C, Pulse: 60 mA
3.6
None
3.4
1
Basic current (bc)
50 µA
100 µA
1
1
2
2
2.8
3
3
2.6
4
2
3.2
3
3.0
4
1: after 2 years at bc
2: after 5 years at bc
2.4
0
0.1
0.2
3: after 8 years at bc
4: after 10 years at bc
0
Time / s
0.1
0
0.1
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
SL-2780/S
Capacity to 2 Volts / Ah
3
LTC Batteries
Size: DD
›› iXtra – long term high performance
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
35 Ah
10 mA
450 mA
1000 mA
90 cm2
10 g
190 g
105 cm3
−55 °C ... +85 °C
Typical Discharge Curves at +25 °C
Voltage / V
3.0
1
2.5
2.0
1:
2:
3:
4:
5:
6:
7:
1.5
1.0
0.5
0.0
0.1
40
2
1
10
Capacity to 2 Volts / Ah
0.7±0.3
Ø 4.2
+0.2
−0.3
0.15 thick
20
1
15
1:
2:
3:
4:
5:
10
Voltage / V
123.5±1
0.1
1
10
Current / mA
3
3.0
2
0.15 thick
123.5±1
Standard
Tags
Catalogue No.
11 2 17901 00
11 2 17902 00
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
17
10 25 40 55
Temperature / °C
300 mA
100 mA
30 mA
10 mA
3 mA
1 mA
0.3 mA
70
85 100
Voltage Response at +25 °C, Pulse: 120 mA
Basic current (bc)
3.4
Voltage / V
3.17
SL-2790/S
SL-2790/T
1:
2:
3:
4:
5:
6:
7:
1
2.8
3.6
+1
1000
7 6
5 4
3.2
3.8
Available Terminations
100
Operating Voltage
−50 −35 −20 −5
Ø 32.9−0.7
5
2.4
12−2
105
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
2.6
0.7±0.3
Ø 4.2
104
4
25
3.4
SL-2790/T
20.2 Ah
28.7 Ah
33.4 Ah
35.0 Ah
32.5 Ah
30.2 Ah
27.5 Ah
3.6
3.17
+0.2
−0.3
7
3
0
0.01
12
103
6
2
30
3.8
5
Available Capacity
5
+1
−2
4
10 Ω ~300 mA
33 Ω ~100 mA
100 Ω ~30 mA
330 Ω ~10 mA
1.0 kΩ
~3 mA
3.3 kΩ
~1 mA
10 kΩ ~0.3 mA
102
Time / h
35
SL-2790/S
3
3.2
None
100 µA
200 µA
1
2
1
1
2
2
3
4
3
3
3.0
4
2.8
2.6
1: after 2 years at bc
2: after 5 years at bc
2.4
0
0.1
3: after 8 years at bc
4: after 10 years at bc
0.2 0
Time / s
0.1
0
0.1
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
SL-2790
LTC Batteries
Size: 1⁄10C
›› XOL – extended operating life
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
0.55 Ah
0.5 mA
5 mA
10 mA
4.3 cm2
0.2 g
8.8 g
2.6 cm3
−55 °C ... +85°C
Voltage / V
3.0
Capacity to 2 Volts / Ah
0.6
4
23
Voltage / V
10.6 max.
TL-2450 (without insolation disc)
1
10
3
102
Time / h
103
0.53 Ah
0.55 Ah
0.54 Ah
0.50 Ah
0.45 Ah
0.42 Ah
104
105
4
1:
2:
3:
4:
5:
+80 °C
+50 °C
+25 °C
0 °C
−30 °C
5
0.1
1
10
Current / mA
100
1000
Operating Voltage
3
2
3.2
3.0
1
2.8
1:
2 mA
2: 0.2 mA
3: 0.02 mA
10 25 40 55
Temperature / °C
70
85 100
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
18
PDC16Eng
PDC16aEng
Catalogue No.
6
1
0.1
2.4
Pins (with insolation disc)
11 1 13763 02
Pins (without insolation disc) 11 1 13763 22
5
2
−50 −35 −20 −5
Available Terminations
4
Available Capacity
0.2
2.6
7.62
3
1: 3.3 kΩ
~1 mA
2: 10 kΩ
~0.3 mA
3: 33 kΩ
~0.1 mA
4: 100 kΩ ~0.03 mA
5: 330 kΩ ~0.01 mA
6: 1000 kΩ ~0.003 mA
s 10
0.3
3.4
2
5 6
0 2 4 6
0.4
3.6
7.62
5.6±0.2
2
0.5
3.8
TL-2450/P
TL-2450/P
1
3
0.0
0.01
10.6 max.
6±0.2
1.5
0.0
0.1
(−) (+)
Ø 0.785
4
2.0
0.5
TL-2450 (with insolation disc)
Ø 0.785
1
2.5
1.0
A high temperature version TLH-2450 is also available.
For more information please refer to Tadiran’s website.
Ø 24.0 +0.5 max.
Typical Discharge Curves at +25 °C
Volts
TL-2450
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries
Size: 1⁄10D
›› XOL – extended operating life
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
1 Ah
0.5 mA
10 mA
20 mA
7.5 cm2
0.3 g
16 g
5 cm3
−55 °C ... +85 °C
Voltage / V
3.0
4
2.0
1.5
1
3
4
23
2
0.5
0 2 4 6
0.0
0.1
Capacity to 2 Volts / Ah
15.24
(–)
2
3
4
5
6
5 6
1:
2:
3:
4:
5:
6:
1.0
SL-889
(–)
1
2.5
1.2
(+)
Typical Discharge Curves at +25 °C
Volts
SL-889
s 10
1
10
1.0 kΩ
~3 mA
3.3 kΩ
~1 mA
10 kΩ ~0.3 mA
33 kΩ ~0.1 mA
100 kΩ ~0.03 mA
330 kΩ ~0.01 mA
102
Time / h
103
0.98 Ah
1.00 Ah
0.98 Ah
0.95 Ah
0.92 Ah
0.85 Ah
104
105
Available Capacity
1.0
0.8
0.6
3
2
1
1:
2:
3:
4:
5:
0.4
0.2
0.0
0.01
4
5
+80 °C
+50 °C
+25 °C
0 °C
−30 °C
0.1
1
10
Current / mA
100
1000
70
85 100
Ø 33.0−0.8
7.62
(9.6)
3.4
Voltage / V
Ø 0.76
Operating Voltage
3.6
2 min.
3.2±0.5
6.2±0.3
3.8
3.2
3.0
2.8
2.6
2.4
1:
3 mA
2: 0.3 mA
3: 0.03 mA
−50 −35 −20 −5
Catalogue No.
SL-889/P
11 1 18894 00
Pins
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
19
PDC16Eng
Available Terminations
10 25 40 55
Temperature / °C
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries
Size: 1⁄6D
›› XOL – extended operating life
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
1.7 Ah
0.5 mA
10 mA
20 mA
7.5 cm2
0.5 g
21 g
8.2 cm3
−55 °C ... +85 °C
Voltage / V
3.0
4
2.0
1.5
2
0.5
0 2 4 6
0.0
0.1
Capacity to 2 Volts / Ah
15.24
(−)
(13.1)
4
5
6
1:
2:
3:
4:
5:
6:
s 10
10
1.0 kΩ
~3 mA
3.3 kΩ
~1 mA
10 kΩ ~0.3 mA
33 kΩ ~0.1 mA
100 kΩ ~0.03 mA
330 kΩ ~0.01 mA
102
Time / h
103
1.50 Ah
1.70 Ah
1.65 Ah
1.60 Ah
1.50 Ah
1.40 Ah
104
105
3
2
4
1
1.0
1:
2:
3:
4:
5:
0.5
3.8
3
5 6
1
1.5
Ø 33.0−0.8
2
Available Capacity
0.0
0.01
5
+80 °C
+50 °C
+25 °C
0 °C
−30 °C
0.1
1
10
Current / mA
100
1000
70
85 100
Operating Voltage
3.6
3.2±0.5
9.9±0.3
4
23
1
3
1.0
SL-886
(−)
1
2.5
2.0
(+)
Typical Discharge Curves at +25 °C
Volts
SL-886
7.62
2 min.
Ø 0.76
Voltage / V
3.4
3.2
3.0
2.8
2.6
2.4
1:
3 mA
2: 0.3 mA
3: 0.03 mA
−50 −35 −20 −5
Catalogue No.
SL-886/P
11 1 18864 00
Pins
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
20
PDC16Eng
Available Terminations
10 25 40 55
Temperature / °C
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries
Size: ½AA
›› XOL – extended operating life
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
1.2 Ah
0.5 mA
20 mA
50 mA
6 cm2
0.35 g
9.6 g
4 cm3
−55 °C ... +85 °C
Voltage / V
3.0
1
2.5
4
2.0
1.5
1
3
4
23
2
0.5
0 2 4 6
0.0
0.1
SL-850/T
25.2–1.2
0.7±0.3
+0.2
−0.3
Capacity to 2 Volts / Ah
SL-850/S
s 10
1
10
4
5
6
1:
2:
3:
4:
5:
6:
1.8 kΩ
~2 mA
5.6 kΩ
~0.6 mA
18 kΩ
~0.2 mA
56 kΩ ~0.06 mA
180 kΩ ~0.02 mA
560 kΩ ~0.006 mA
102
Time / h
103
0.80 Ah
1.20 Ah
1.15 Ah
1.05 Ah
1.00 Ah
0.90 Ah
104
105
4
3
2
5
1
0.6
1:
2:
3:
4:
5:
0.4
0.2
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
0.0
0.01
7±0.5
3
Available Capacity
1.0
0.8
2
5 6
1.0
1.2
Ø 4.2
Typical Discharge Curves at +25 °C
Volts
SL-850
0.1
1
10
Current / mA
3.17
100
1000
70
85 100
0.15 thick
SL-850/P
Ø 14.7
3.8
45
SL-850/PT
2
3.2
3.0
1
2.8
2.6
SL-850/PR
3
3.4
Voltage / V
Ø 0.8
45
Operating Voltage
3.6
Ø 0.8
–1.2
2.4
1:
2 mA
2: 0.2 mA
3: 0.02 mA
10 25 40 55
Temperature / °C
3.5
4+0.5
1–0.1
1–0.1
0.2 thick
0.2 thick
Available Terminations
Catalogue No.
SL-850/S
SL-850/T
SL-850/P
SL-850/PR
SL-850/PT
11 1 08501 00
11 1 08502 00
11 1 08503 00
11 1 08506 00
11 1 08508 00
Standard
Tags
Pins
Pins radial
Polarized tags
10.16
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
21
PDC16Eng
3.5
4+0.5
−50 −35 −20 −5
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries
Size: 2⁄3AA
›› XOL – extended operating life
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
1.6 Ah
0.5 mA
30 mA
75 mA
9 cm2
0.5 g
12.5 g
5.2 cm3
−55 °C ... +85 °C
Voltage / V
3.0
1
2.5
4
2.0
1.5
2
0.5
4
23
SL-861/T
+0.2
−0.3
0.7±0.3
Ø 4.2
Capacity to 2 Volts / Ah
SL-861/S
1.2
33.5−1.5
3.17
3
4
5
6
10
1:
2:
3:
4:
5:
6:
1.0 kΩ
~3 mA
3.3 kΩ
~1 mA
10 kΩ ~0.3 mA
33 kΩ ~0.1 mA
100 kΩ ~0.03 mA
330 kΩ ~0.01 mA
102
Time / h
103
1.20 Ah
1.60 Ah
1.60 Ah
1.55 Ah
1.45 Ah
1.35 Ah
104
105
Available Capacity
4
5
3
2
1
1.0
0.8
0.6
1:
2:
3:
4:
5:
0.4
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
0.0
0.01
7
s 10
1
0.2
±0.5
2
5 6
0 2 4 6
0.0
0.1
1.4
0.1
1
10
Current / mA
100
1000
70
85 100
0.15 thick
3.8
45
SL-861/PT
2
3.2
3.0
1
2.8
2.6
SL-861/PR
3
3.4
Voltage / V
45
Operating Voltage
3.6
Ø 0.8
Ø 0.8
SL-861/P
Ø 14.7−1.2
1
3
1.0
1.6
+
Typical Discharge Curves at +25 °C
Volts
SL-861
2.4
1:
3 mA
2: 0.3 mA
3: 0.03 mA
10 25 40 55
Temperature / °C
3.5
4+0.5
1−0.1
1−0.1
0.2 thick
0.2 thick
Available Terminations
Catalogue No.
SL-861/S
SL-861/T
SL-861/P
SL-861/PR
SL-861/PT
11 1 08611 00
11 1 08612 00
11 1 08613 00
11 1 08616 00
11 1 08618 00
Standard
Tags
Pins
Pins radial
Polarized tags
10.16
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
22
PDC16Eng
3.5
4+0.5
−50 −35 −20 −5
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries
Size: AA
›› XOL – extended operating life
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
2.4 Ah
1 mA
60 mA
120 mA
14 cm2
0.65 g
18 g
8 cm3
−55 °C ... +85 °C
Typical Discharge Curves at +25 °C
Voltage / V
3.0
1
2.5
4
2.0
Volts
SL-860
1.5
1
3
4
23
2
0 2 4 6
0.0
0.1
2.5
3
4
5
6
5 6
1: 560 Ω
~6 mA
2: 1.8 kΩ
~2 mA
3: 5.6 kΩ ~0.6 mA
4: 18 kΩ ~0.2 mA
5: 56 kΩ ~0.06 mA
6: 180 kΩ ~0.02 mA
1.0
0.5
2
s 10
1
10
102
Time / h
103
1.90 Ah
2.40 Ah
2.40 Ah
2.30 Ah
2.15 Ah
2.00 Ah
104
105
Available Capacity
SL-860/S
SL-860/T
+0.2
+
0.7±0.3
Ø 4.2−0.3
Capacity to 2 Volts / Ah
4
3
2
5
1
1.5
1.0
1:
2:
3:
4:
5:
0.5
0.0
0.01
7±0.5
50.5−1.5
2.0
0.1
1
10
Current / mA
3.17
100
1000
70
85 100
0.15 thick
45
3
3.4
45
SL-860/PT
2
3.2
3.0
1
2.8
2.6
SL-860/PR
Operating Voltage
3.6
Voltage / V
Ø 14.7–1.2
3.8
Ø 0.8
Ø 0.8
SL-860/P
2.4
1:
6 mA
2: 0.6 mA
3: 0.06 mA
10 25 40 55
Temperature / °C
3.5
4+0,5
1−0.1
1−0.1
0.2 thick
0.2 thick
Available Terminations
Catalogue No.
SL-860/S
SL-860/T
SL-860/P
SL-860/PR
SL-860/PT
11 1 08601 00
11 1 08602 00
11 1 08603 00
11 1 08606 00
11 1 08608 00
Standard
Tags
Pins
Pins radial
Polarized tags
10.16
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
23
PDC16Eng
4+0,5
−50 −35 −20 −5
3.5
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries
Size: C
›› XOL – extended operating life
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
8.5 Ah
3 mA
75 mA
200 mA
30 cm2
2.5 g
49.5 g
26 cm3
−55 °C ... +85 °C
Typical Discharge Curves at +25 °C
Voltage / V
3.0
1
2.5
4
2.0
Volts
SL-2870
1.5
3
2
1
2
0 2 4 6
0.0
0.1
SL-2870/S
SL-2870/T
+0.2
0.7±0.3
Ø 4.2−0.3
Capacity to 2 Volts / Ah
10
50.0−2
0.15 thick
Voltage / V
Ø 0.8
Ø 0.8
11 2 18701 00
11 2 18702 00
11 2 18703 00
Standard
Tags
Pins
103
104
105
3
5
4
4
1:
2:
3:
4:
5:
2
0.1
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
1
10
Current / mA
100
1000
70
85 100
Operating Voltage
3
2
3.2
3.0
1
2.8
2.4
1: 10 mA
2: 1 mA
3: 0.1 mA
10 25 40 55
Temperature / °C
45
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
24
PDC16Eng
SL-2870/S
SL-2870/T
SL-2870/P
102
Time / h
2
−50 −35 −20 −5
Catalogue No.
330 Ω ~10 mA 6.0 Ah
1.0 kΩ ~3 mA 8.4 Ah
3.3 kΩ ~1 mA 8.5 Ah
10 kΩ ~0.3 mA 8.2 Ah
33 kΩ ~0.1 mA 7.7 Ah
1
6
2.6
45
5
Available Capacity
3.4
SL-2870/P
4
3.6
3.17
Ø 26.2−1
10
8
3.8
+1
Available Terminations
1:
2:
3:
4:
5:
s 10
1
0
0.01
16−2
3
5
3 4
1.0
0.5
2
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries
Size: D
›› XOL – extended operating life
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.5
Lithium Thionyl Chloride
3.6 V
19 Ah
4 mA
100 mA
250 mA
45 cm2
5g
93 g
51 cm3
−55 °C ... +85 °C
Voltage / V
3.0
1
2.5
4
2.0
1.5
2
0.5
0 2 4 6
0.0
0.1
SL-2880/T
+0.2
Ø 4.2−0.3
0.7±0.3
Capacity to 2 Volts / Ah
SL-2880/S
61.5−2
+1
10
2
102
Time / h
103
104
105
4
10
1:
2:
3:
4:
5:
5
5
+80 °C
+50 °C
+25 °C
0 °C
−30 °C
0.1
1
10
Current / mA
100
1000
70
85 100
Operating Voltage
3
Voltage / V
2
3.2
3.0
1
2.8
2.4
1: 20 mA
2: 2 mA
3: 0.2 mA
10 25 40 55
Temperature / °C
Ø 0.8
−50 −35 −20 −5
Ø 0.8
180 Ω ~20 mA 13.5 Ah
560 Ω ~6 mA 17.5 Ah
1.8 kΩ ~2 mA 18.8 Ah
5.6 kΩ ~0.6 mA 18.3 Ah
18 kΩ ~0.2 mA 17.0 Ah
3
2.6
SL-2880/P
5
1
3.4
Ø 32.9−0.7
4
3.6
0.15 thick
3.17
3
Available Capacity
15
3.8
45
Catalogue No.
SL-2880/S
SL-2880/T
SL-2880/P
11 2 18801 00
11 2 18802 00
11 2 18803 00
45
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
25
PDC16Eng
Available Terminations
Standard
Tags
Pins
1:
2:
3:
4:
5:
s 10
1
0
0.01
12−2
2
5
3 4
2
1
3
1.0
20
+
Typical Discharge Curves at +25 °C
Volts
SL-2880
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PulsesPlusTM Batteries
Introduction
Performance
As a result, the PulsesPlusTM
battery outperforms conventional high rate lithium bat4.0
Impedance Loss and how to Overcome it
R-420
1
3.5
SL-2880 @ +25 °C
cont. load: 68 kΩ (~50 µA)
pulse load: 150 mA
1: Voltage on background current
2: Pulse voltage
3.0
Voltage / V
No impedance loss
The PulsesPlus TM battery
overcomes the impedance
loss which occurs when an LTC
battery is used to deliver high
pulse currents over a long
time. This effect is demonstrated in figure 1 where a D-size
2
2.5
2.0
1.5
1.0
HLC-1520 connected
0.5
0.0
0
5
10
15
Working time / years
than 10 or 20 years. However,
after 2 years, the voltage
level under pulse load starts
to decline reaching as low as
1.5 Volts after 5 years. At this
voltage level, most applications would stop to work and
the battery would be considered as discharged. However,
it is not, as can be seen from
the red curve showing the battery voltage under background
load. It stays at 3.6 Volts,
even after 5 and 10 years.
Connecting Tadiran’s Hybrid
Layer Capacitor (HLC) in parallel solves the problem. The
HLC maintains its low internal
resistance throughout the
remaining battery life. During
that time period the pulse
voltage stays always above 3.4
Volts. The duration for that
test is more than 14 years.
Application in
GSM modules
One major application for
PulsesPlus TM batteries is in
GSM communication modules
for data exchange. GSM is
the global system for mobile
communication also used
for mobile phones. The GSM
network uses a multiplexing
technology called time division multiple access (TDMA)
in order to provide multiple
communication channels with
the same signal, dividing it
into 8 time slots. A typical
TDMA transmission requires
a basic current of 150 mA
and a pulse current of 2 A
for 577 µs every 4.615 ms.
Figure 2 shows the voltage
behaviour of a Pulses­Plus TM
battery with one HLC-1550A
under these conditions at
320
How to Design a Long Life Application
280
1: +70 °C
2: +55 °C
3: +25 °C
240
3
2
1
200
160
TLP-93111/A
(SL-2880, D-size, XOL cell,
19 Ah nominal capacity,
with HLC-1550A)
120
80
40
0
0
5
10
15
20
25
Typical battery design life / years
Figure 3: How to Design a Long Life Application
various temperature levels
between −40 °C and +25 °C.
The chart shows two curves
for each temperature level.
The upper curve corresponds
to the voltage level under the
background current of 150 mA
while the lower curve corresponds to the voltage level
under the peak current of 2 A.
Curves at higher temperatures
are not shown but can be considered to lie slightly above
the curves for +25 °C.
Extremely low
self discharge
The PulsesPlus TM battery can
be used where 20 years of
continuous power are required
for applications including
GSM and radio modules. This
is due to the stability of both
Tadiran’s primary LTC battery
and the HLC with respect
to the sealing system, the
internal resistance, and the
self-discharge.
20
4.0
Figure 1: Impedance Loss and how to Overcome it
GSM Discharge Curves
3.5
cell was discharged under a
continuous load of ~50 µA and
short pulses of 150 mA.
The battery is able to deliver this current at a voltage
level of 3 Volts, at least for a
period of 2 years. From the
low average current draw of
50 µA, one would be misled
to assume that the battery
could continue to deliver
these pulse currents for more
3.0
Voltage / V
teries such as lithium sulphur
dioxide (Li/SO2) batteries,
lithium manganese dioxide
(Li/MnO2) batteries as well as
spirally wound lithium thionyl
chloride (Li/SOCl2) batteries.
Compared to these battery
systems, PulsesPlusTM batteries deliver higher voltage and
higher capacity. These batteries
also offer unmatched service
life due to their extremely low
self-discharge.
2.5
5
2.0
1.0
0.5
0.0
4
3
2
1
7
6
HLC-1550A charged to 3.6 V
GSM profile (TDMA, 1 Slot)
150 mA continuous current
2 A peak current for 577 µs every 4.615 ms
1: +25 °C
2: +10 °C
3: 0 °C
4: −10 °C
5: −20 °C
6: −30 °C
7: −40 °C
1.5
0
5
30
10
15
Time / min
20
25
Fit for 20 years of life
Figure 3 shows the maximum
average current draw of a TLP93111/A PulsesPlusTM battery
as a function of the design life
of the battery. This battery will
typically deliver 20 years operation life when the average current is not more than 87.5 µA at
+25 °C. Under these conditions,
the accumulated self discharge
loss of the battery is less than
15 % during its operating life.
As a result it is fair to say that
Tadiran’s Pulses­PlusTM battery
is the smallest and most cost
effective battery for a 20 year
stand alone power supply.
Variable design
PulsesPlusTM batteries can be
assembled in a great variety of
combinations. The primary cell
can be selected from Tadiran’s
large range of 3.6 Volt LTC batteries. A special range of LSC
(Lithium Sulphuryl Chloride)
cells with a nominal voltage
of 3.9 Volts is also available,
often allowing a more economic
approach where equipment
needs to operate at very low
temperatures. Each of these
primary cells can be combined
with one or more HLCs from a
range of four sizes. Series and
parallel combinations of more
primary cells extend the voltage
range and capacity range where
necessary. Only a few standard
combinations can be shown in
this catalogue. Contact Tadiran
for a customized application
proposal.
Figure 2: GSM Discharge Curves
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
26
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
The Hybrid Layer Capacitor
This HLC is a secondary element.
Its electrodes comprise Lithium
Intercalated Compounds and
are spirally wound. The HLC has
been optimized with respect
to self discharge, temperature
range and durability by carefully
selecting the material properties
of the electrodes and the hermetical glass to metal seal.
Advantages
The performance advantages of the PulsesPlusTM
battery include:
Higher voltage – 3.6 V
versus 3.0 V
Higher capacity – e.g. 19 Ah
for D size cell (versus 7 Ah
for other Lithium batteries)
Lower self discharge – less
than 1 % per year
(versus 5 % per year
with spiral wound)
Lower impedance
(internal resistance)
High pulse current
capability
No passivation effect
High reliability
(hermetic laser sealing,
glass-to-metal seal)
Widest operating temperature – −40 °C to +85 °C
(versus 0 °C to +60 °C)
Greater safety, UL registration of the component cells
Max. avg. current draw / μA
The PulsesPlus TM battery
The PulsesPlusTM battery series
was introduced by Tadiran
Batteries in order to extend
the range of applications for
the Lithium Thionyl Chloride
(LTC) battery by eliminating the
voltage delay, increasing the
pulse current capability and
minimizing the impedance loss
of the battery. A proprietary Hybrid Layer Capacitor (HLC) was
developed for this purpose. A
PulsesPlus TM battery is formed
by connecting one or more
primary lithium thionyl chloride
batteries in parallel with one or
more HLCs.
›› High energy
›› Up to 3 A pulse capability
›› Instant voltage response
›› No passivation effect
TLP-91111/A
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. 1 s pulse to 3 V
Max. pulse length @ 0.5 A to 2.8 V
Delay time to 3 V @ 0.5 A
Weight
Temperature range
Capacity retention after 10 year storage
3.8
Voltage / V
LTC and HLC
3.6 V
2.4 Ah
2 mA
3A
1000 s
none
55 g
−40 °C ... +85 °C
87 %
Voltage during a Pulse at +25 °C
3.6
1
2
3
3.4
1: 300 mA
2: 750 mA
3: 1500 mA
3.2
3.0
2.8
0.01
4.0
0.1
Pulse amplitude / A
100±10
1:
2:
3:
4:
5:
3.0
2.5
4&5
1.5
3
1.0
2
55 max.
0.5
1
0.0
0.01
F
0.1
1
10
102
Pulse width / s
103
104
Pulse Voltage after 1 s
3.8
C
Voltage / V
B
104
−40 °C
−20 °C
0 °C
+25 °C
+85 °C
2.0
4.0
103
Maximum Pulse Width from 3.6 V to 2.8 V
3.5
TLP-91111/A/SM
1
10
102
Pulse duration / s
32 max.
B = LTC battery
C = HLC
F = PTC (optional)
3.6
3.4
1 2
1: 300 mA
2: 600 mA
3: 1000 mA
3
3.2
3.0
Both the LTC battery and the
HLC are UL recognized.
16 max.
2.8
−50 −35 −20 −5
2.5
10 25 40 55
Temperature / °C
70
85 100
100
1000
Available Capacity
Catalogue No.
TLP-91111/A/SM
17 91111 101
Flying leads
WARNING:
Risk of fire or explosion.
Do not charge, incinerate,
disassemble, heat above
100 °C, or expose
contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
2
1.5
5
1
1.0
1:
2:
3:
4:
5:
0.5
0.0
0.01
27
3
0.1
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
1
10
Current / mA
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
Available Terminations
Capacity to 2 Volts / Ah
4
2.0
›› High energy
›› Up to 1 A pulse capability
›› Instant voltage response
›› No passivation effect
TLP-91311/A
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. 1 s pulse to 3 V
Max. pulse length @ 0.125 A to 2.8 V
Delay time to 3 V @ 0.125 A
Weight
Temperature range
Capacity retention after 10 year storage
3.8
Voltage / V
LTC and HLC
3.6 V
2.4 Ah
2 mA
1A
1000 s
none
40 g
−40 °C ... +85 °C
90 %
Voltage during a Pulse at +25 °C
3.6
1
3.0
2.8
0.01
0.1
Pulse amplitude / A
+
TLP-91311/A/ST
Ø7
Ø7
+
+
Ø7
+
18±2
18±2
1:
2:
3:
4:
5:
0.8
104
−40 °C
−20 °C
0 °C
+25 °C
+85 °C
4&5
3
0.4
2
0.2
1
75 max.
4.0
F
B
C
B = LTC battery
C = HLC
F = PTC (optional)
1
10
102
Pulse width / s
103
104
Pulse Voltage after 1 s
3.6
3.4
1 2
1: 100 mA
2: 200 mA
3: 300 mA
3
3.2
3.0
Both the LTC battery and the
HLC are UL recognized.
Ø 16.5 max. Ø 16.5 max.
23±2
0.1
3.8
Voltage / V
75 max.
75 max.
103
0.6
0.0
0.01
Ø 16.5 max. Ø 16.5 max.
1
10
102
Pulse duration / s
Maximum Pulse Width from 3.6 V to 2.8 V
1.0
Ø7
3
1: 100 mA
2: 250 mA
3: 500 mA
3.2
1.2
TLP-91311/A/SM
2
3.4
2.8
−50 −35 −20 −5
23±2
2.5
10 25 40 55
Temperature / °C
70
85 100
100
1000
Available Capacity
Catalogue No.
TLP-91311/A/SM
TLP-91311/A/ST
17 91311 101
17 91311 102
Pressure contacts
Solder tags
WARNING:
Do not charge. Battery can
explode if disassembled,
heated above 100 °C,
incinerated, or contents
exposed to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
2
1.5
5
1
1.0
1:
2:
3:
4:
5:
0.5
0.0
0.01
28
3
0.1
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
1
10
Current / mA
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
Available Terminations
Capacity to 2 Volts / Ah
4
2.0
›› High energy
›› Up to 3 A pulse capability
›› Instant voltage response
›› No passivation effect
TLP-92111/A
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. 1 s pulse to 3 V
Max. pulse length @ 0.5 A to 2.8 V
Delay time to 3 V @ 0.5 A
Weight
Temperature range
Capacity retention after 10 year storage
3.8
Voltage / V
LTC and HLC
3.6 V
8.5 Ah
3 mA
3A
1000 s
none
100 g
−40 °C ... +85 °C
93 %
Voltage during a Pulse at +25 °C
3.6
1
3
1: 300 mA
2: 750 mA
3: 1500 mA
3.2
3.0
2.8
0.01
4.0
Pulse amplitude / A
TLP-92111/A/SM
100±10
0.1
1
10
102
Pulse duration / s
1:
2:
3:
4:
5:
3.0
2.5
2.0
4&5
1.5
3
1.0
2
C
B = LTC battery
C = HLC
F = PTC (optional)
17 92111 101
Capacity to 2 Volts / Ah
WARNING:
Risk of fire or explosion.
Do not charge, incinerate,
disassemble, heat above
100 °C, or expose
contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
104
Pulse Voltage after 1 s
3.4
1 2
10 25 40 55
Temperature / °C
70
85 100
100
1000
Available Capacity
8
6
3
2
1
5
4
4
1:
2:
3:
4:
5:
2
0
0.01
29
1: 300 mA
2: 600 mA
3: 1000 mA
3
3.2
2.8
−50 −35 −20 −5
28 max.
TLP-92111/A/SM
103
3.6
10
Catalogue No.
10
102
Pulse width / s
3.0
Both the LTC battery and the
HLC are UL recognized.
Available Terminations
1
3.8
Voltage / V
44 max.
0.1
0.1
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
1
10
Current / mA
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
55 max.
F
B
1
0.0
0.01
4.0
104
−40 °C
−20 °C
0 °C
+25 °C
+85 °C
0.5
Note:
For best performance battery
should be mounted in the application in upright
or horizontal orientation.
103
Maximum Pulse Width from 3.6 V to 2.8 V
3.5
Flying leads
2
3.4
›› High energy
›› Up to 1 A pulse capability
›› Instant voltage response
›› No passivation effect
TLP-92311/A
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. 1 s pulse to 3 V
Max. pulse length @ 0.125 A to 2.8 V
Delay time to 3 V @ 0.125 A
Weight
Temperature range
Capacity retention after 10 year storage
3.8
Voltage / V
LTC and HLC
3.6 V
8.5 Ah
3 mA
1A
1000 s
none
80 g
−40 °C ... +85 °C
93 %
Voltage during a Pulse at +25 °C
3.6
1
2
3
3.4
1: 100 mA
2: 250 mA
3: 500 mA
3.2
3.0
2.8
0.01
1.2
Pulse amplitude / A
75±10
1
10
102
Pulse duration / s
103
104
Maximum Pulse Width from 3.6 V to 2.8 V
1:
2:
3:
4:
5:
1.0
TLP-92311/A/SM
0.1
0.8
−40 °C
−20 °C
0 °C
+25 °C
+85 °C
0.6
4&5
3
0.4
2
0.2
1
0.0
0.01
4.0
F
C
B = LTC battery
C = HLC
F = PTC (optional)
Ø 29 max.
TLP-92311/A/SM
17 92311 101
Flying leads
104
Pulse Voltage after 1 s
3.4
1 2
10 25 40 55
Temperature / °C
70
85 100
100
1000
Available Capacity
8
6
3
2
1
5
4
4
1:
2:
3:
4:
5:
2
0
0.01
30
1: 100 mA
2: 200 mA
3: 300 mA
3
3.2
2.8
−50 −35 −20 −5
Capacity to 2 Volts / Ah
WARNING:
Risk of fire or explosion.
Do not charge, incinerate,
disassemble, heat above
100 °C, or expose
contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
103
3.6
10
Catalogue No.
10
102
Pulse width / s
3.0
Both the LTC battery and the
HLC are UL recognized.
Available Terminations
1
3.8
Voltage / V
B
0.1
0.1
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
1
10
Current / mA
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
67 max.
Note:
For best performance battery
should be mounted in the application in upright
or horizontal orientation.
›› High energy
›› Up to 3 A pulse capability
›› Instant voltage response
›› No passivation effect
TLP-93111/A
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. 1 s pulse to 3 V
Max. pulse length @ 0.5 A to 2.8 V
Delay time to 3 V @ 0.5 A
Weight
Temperature range
Capacity retention after 10 year storage
3.8
Voltage / V
LTC and HLC
3.6 V
19 Ah
4 mA
3A
1000 s
none
140 g
−40 °C ... +85 °C
96 %
Voltage during a Pulse at +25 °C
3.6
1
3
1: 300 mA
2: 750 mA
3: 1500 mA
3.2
3.0
2.8
0.01
4.0
0.1
Pulse amplitude / A
TLP-93111/A/SM
1
10
102
Pulse duration / s
1:
2:
3:
4:
5:
3.0
2.5
2.0
4&5
1.5
3
1.0
2
1
0.0
0.01
Note:
For best performance battery
should be mounted in the application in upright
or horizontal orientation.
C
0.1
1
10
102
Pulse width / s
103
104
Pulse Voltage after 1 s
3.8
Voltage / V
F
B
4.0
104
−40 °C
−20 °C
0 °C
+25 °C
+85 °C
0.5
100±10
103
Maximum Pulse Width from 3.6 V to 2.8 V
3.5
64 max.
2
3.4
3.6
3.4
1 2
1: 300 mA
2: 600 mA
3: 1000 mA
3
3.2
3.0
50 max.
2.8
−50 −35 −20 −5
Both the LTC battery and the
HLC are UL recognized.
Available Terminations
Catalogue No.
TLP-93111/A/SM
17 93111 101
Flying leads
Capacity to 2 Volts / Ah
35 max.
20
WARNING:
Risk of fire or explosion.
Do not charge, incinerate,
disassemble, heat above
100 °C, or expose
contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
70
85 100
100
1000
Available Capacity
2
15
4
1
3
10
5
0
0.01
31
10 25 40 55
Temperature / °C
1:
2:
3:
4:
5:
+80 °C
+50 °C
+25 °C
0 °C
−30 °C
0.1
5
1
10
Current / mA
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
B = LTC battery
C = HLC
F = PTC (optional)
›› High energy
›› Up to 1 A pulse capability
›› Instant voltage response
›› No passivation effect
TLP-93311/A
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. 1 s pulse to 3 V
Max. pulse length @ 0.125 A to 2.8 V
Delay time to 3 V @ 0.125 A
Weight
Temperature range
Capacity retention after 10 year storage
3.8
Voltage / V
LTC and HLC
3.6 V
19 Ah
4 mA
1A
1000 s
none
120 g
−40 °C ... +85 °C
96 %
Voltage during a Pulse at +25 °C
3.6
1
2
3
3.4
1: 100 mA
2: 250 mA
3: 500 mA
3.2
3.0
2.8
0.01
1.2
0.1
Pulse amplitude / A
103
104
Maximum Pulse Width from 3.6 V to 2.8 V
1:
2:
3:
4:
5:
1.0
TLP-93311/A/SM
1
10
102
Pulse duration / s
0.8
−40 °C
−20 °C
0 °C
+25 °C
+85 °C
0.6
4&5
3
0.4
2
0.2
1
0.0
0.01
75±10
F
B
4.0
C
1
10
102
Pulse width / s
103
104
Pulse Voltage after 1 s
3.8
Voltage / V
78 max.
Note:
For best performance battery
should be mounted in the application in upright
or horizontal orientation.
0.1
3.6
3.4
1 2
1: 100 mA
2: 200 mA
3: 300 mA
3
3.2
3.0
2.8
−50 −35 −20 −5
Both the LTC battery and the
HLC are UL recognized.
20
Available Terminations
Catalogue No.
TLP-93311/A/SM
17 93311 101
Flying leads
Capacity to 2 Volts / Ah
Ø 34 max.
WARNING:
Risk of fire or explosion.
Do not charge, incinerate,
disassemble, heat above
100 °C, or expose
contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
70
85 100
100
1000
Available Capacity
2
15
4
1
3
10
5
0
0.01
32
10 25 40 55
Temperature / °C
1:
2:
3:
4:
5:
+80 °C
+50 °C
+25 °C
0 °C
−30 °C
0.1
5
1
10
Current / mA
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
B = LTC battery
C = HLC
F = PTC (optional)
›› High energy
›› Up to 3 A pulse capability
›› Instant voltage response
›› No passivation effect
TLP-96111/A
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. 1 s pulse to 3 V
Max. pulse length @ 0.5 A to 2.8 V
Delay time to 3 V @ 0.5 A
Weight
Temperature range
Capacity retention after 10 year storage
3.8
Voltage / V
LTC and HLC
3.6 V
1.2 Ah
0.6 mA
3A
1000 s
none
45 g
−40 °C ... +85 °C
78 %
Voltage during a Pulse at +25 °C
3.6
1
3.0
2.8
0.01
0.1
Pulse amplitude / A
TLP-96111/A/SM
100±10
1
10
102
Pulse duration / s
1:
2:
3:
4:
5:
3.0
2.5
4&5
1.5
3
1.0
2
0.5
1
55 max.
0.0
0.01
F
C
Capacity to 2 Volts / Ah
WARNING:
Risk of fire or explosion.
Do not charge, incinerate,
disassemble, heat above
100 °C, or expose
contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
104
Pulse Voltage after 1 s
3.4
1 2
70
85 100
100
1000
4
3
1.0
0.8
10 25 40 55
Temperature / °C
Available Capacity
2
5
1
0.6
0.4
0.2
0.0
0.01
33
1: 300 mA
2: 600 mA
3: 1000 mA
3
3.2
2.8
−50 −35 −20 −5
16 max.
17 96111 101
103
3.6
1.2
Flying leads
10
102
Pulse width / s
3.0
Both the LTC battery and the
HLC are UL recognized.
TLP-96111/A/SM
1
1:
2:
3:
4:
5:
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
0.1
1
10
Current / mA
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
B = LTC battery
C = HLC
F = PTC (optional)
Catalogue No.
0.1
3.8
Voltage / V
B
104
−40 °C
−20 °C
0 °C
+25 °C
+85 °C
2.0
4.0
103
Maximum Pulse Width from 3.6 V to 2.8 V
3.5
Available Terminations
3
1: 300 mA
2: 750 mA
3: 1500 mA
3.2
4.0
32 max.
2
3.4
›› High energy
›› Up to 1 A pulse capability
›› Instant voltage response
›› No passivation effect
TLP-96311/A
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. 1 s pulse to 3 V
Max. pulse length @ 0.125 A to 2.8 V
Delay time to 3 V @ 0.125 A
Weight
Temperature range
Capacity retention after 10 year storage
3.8
Voltage / V
LTC and HLC
3.6 V
1.2 Ah
0.6 mA
1A
1000 s
none
30 g
−40 °C ... +85 °C
83 %
Voltage during a Pulse at +25 °C
3.6
1
3.0
2.8
0.01
0.1
Pulse amplitude / A
+
TLP-96311/A/ST
Ø7
Ø7
+
Ø7
+
+
18±2
18±2
1:
2:
3:
4:
5:
0.8
104
−40 °C
−20 °C
0 °C
+25 °C
+85 °C
4&5
3
0.4
2
0.2
1
0.1
1
50 max.
50 max.
103
0.6
0.0
0.01
50 max.
1
10
102
Pulse duration / s
Maximum Pulse Width from 3.6 V to 2.8 V
1.0
Ø7
3
1: 100 mA
2: 250 mA
3: 500 mA
3.2
1.2
TLP-96311/A/SM
2
3.4
4.0
10
102
Pulse width / s
103
104
Pulse Voltage after 1 s
Ø 16.5 max.
Ø 16.5 max.
Ø 16.5 max.
±2
Ø 16.523
max.
Voltage / V
3.8
23±2
3.6
3.4
1 2
1: 100 mA
2: 200 mA
3: 300 mA
3
3.2
3.0
B
2.8
−50 −35 −20 −5
C
B = LTC battery
C = HLC
F = PTC (optional)
Both the LTC battery and the
HLC are UL recognized.
Available Terminations
Catalogue No.
TLP-96311/A/SM
TLP-96311/A/ST
17 96311 101
17 96311 102
Pressure contacts
Solder tags
WARNING:
Do not charge. Battery can
explode if disassembled,
heated above 100 °C,
incinerated, or contents
exposed to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
Capacity to 2 Volts / Ah
1.2
85 100
100
1000
4
3
2
5
1
0.6
0.4
0.2
0.0
0.01
34
70
Available Capacity
1.0
0.8
10 25 40 55
Temperature / °C
1:
2:
3:
4:
5:
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
0.1
1
10
Current / mA
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
F
›› High energy
›› Up to 3 A pulse capability
›› Instant voltage response
›› No passivation effect
TLP-97111/A
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. 1 s pulse to 3 V
Max. pulse length @ 0.5 A to 2.8 V
Delay time to 3 V @ 0.5 A
Weight
Temperature range
Capacity retention after 10 year storage
3.8
Voltage / V
LTC and HLC
3.6 V
1.6 Ah
1 mA
3A
1000 s
none
45 g
−40 °C ... +85 °C
80 %
Voltage during a Pulse at +25 °C
3.6
1
2
3
3.4
1: 300 mA
2: 750 mA
3: 1500 mA
3.2
3.0
2.8
0.01
4.0
0.1
Pulse amplitude / A
100±10
1:
2:
3:
4:
5:
55 max.
B
3.0
2.5
2.0
4&5
1.5
3
1.0
2
1
0.0
0.01
C
B = LTC battery
C = HLC
F = PTC (optional)
4.0
0.1
1
10
102
Pulse width / s
103
104
Pulse Voltage after 1 s
3.8
Voltage / V
Both the LTC battery and the
HLC are UL recognized.
32 max.
104
−40 °C
−20 °C
0 °C
+25 °C
+85 °C
0.5
F
103
Maximum Pulse Width from 3.6 V to 2.8 V
3.5
TLP-97111/A/SM
1
10
102
Pulse duration / s
3.6
3.4
1 2
1: 300 mA
2: 600 mA
3: 1000 mA
3
3.2
3.0
1.6
Available Terminations
Catalogue No.
TLP-97111/A/SM
17 97111 101
Flying leads
Capacity to 2 Volts / Ah
1.4
WARNING:
Risk of fire or explosion.
Do not charge, incinerate,
disassemble, heat above
100 °C, or expose
contents to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
1.2
70
85 100
100
1000
Available Capacity
4
5
3
2
1
1.0
0.8
0.6
0.4
0.2
0.0
0.01
35
10 25 40 55
Temperature / °C
1:
2:
3:
4:
5:
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
0.1
1
10
Current / mA
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
16 max.
2.8
−50 −35 −20 −5
›› High energy
›› Up to 1 A pulse capability
›› Instant voltage response
›› No passivation effect
TLP-97311/A
Performance Data
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Nominal voltage
Nominal capacity
Nominal current
Max. 1 s pulse to 3 V
Max. pulse length @ 0.125 A to 2.8 V
Delay time to 3 V @ 0.125 A
Weight
Temperature range
Capacity retention after 10 year storage
3.8
Voltage / V
LTC and HLC
3.6 V
1.6 Ah
1 mA
1A
1000 s
none
35 g
−40 °C ... +85 °C
85 %
Voltage during a Pulse at +25 °C
3.6
1
3.0
2.8
0.01
0.1
Pulse amplitude / A
Ø7
Ø7
+
+
Ø7
+
18±2
18±2
1:
2:
3:
4:
5:
B
58 max.
58 max.
58 max.
0.8
0.6
2
0.0
0.01
Ø 16.5 max. Ø 16.5 max.
23
±2
0.1
1
4.0
Voltage / V
23
3.6
3.4
1 2
1: 100 mA
2: 200 mA
3: 300 mA
3
3.2
±2
3.0
Capacity to 2 Volts / Ah
1.4
17 97311 101
17 97311 102
104
3.8
1.6
Pressure contacts
Solder tags
103
Pulse Voltage after 1 s
2.8
−50 −35 −20 −5
TLP-97311/A/SM
TLP-97311/A/ST
10
102
Pulse width / s
C
Both the LTC battery and the
HLC are UL recognized.
Catalogue No.
4&5
3
0.4
1
B = LTC battery
C = HLC
F = PTC (optional)
Available Terminations
104
−40 °C
−20 °C
0 °C
+25 °C
+85 °C
0.2
F
Ø 16.5 max. Ø 16.5 max.
103
WARNING:
Do not charge. Battery can
explode if disassembled,
heated above 100 °C,
incinerated, or contents
exposed to water.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
1.2
70
85 100
100
1000
Available Capacity
4
5
3
2
1
1.0
0.8
0.6
0.4
0.2
0.0
0.01
36
10 25 40 55
Temperature / °C
1:
2:
3:
4:
5:
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
0.1
1
10
Current / mA
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
+
TLP-97311/A/ST
1
10
102
Pulse duration / s
Maximum Pulse Width from 3.6 V to 2.8 V
1.0
Ø7
3
1: 100 mA
2: 250 mA
3: 500 mA
3.2
1.2
TLP-97311/A/SM
2
3.4
Hybrid Layer Capacitors (HLCs)
Introduction
Properties
Hybrid Layer Capacitors are a
kind of rechargeable battery.
They are used as a capacitor in
PulsesPlus TM batteries, where
they are connected in parallel
to Tadiran Lithium Batteries.
The electrodes of HLCs comprise Lithium intercalation
compounds. They have low impedance and can deliver high
current pulses. The performance and reliability properties
of HLCs have been carefully
optimized to match those of
Tadiran Lithium Batteries.
The result is a battery with a
maximum of both energy and
power density for stand alone
use of up to 25 years.
Safety
WARNING:
HLCs are designed for use in
PulsesPlus TM batteries. When
used independently, they must
not be fast charged.
−40 °C ... +85 °C
−30 °C ... +60 °C
for operation in PulsesPlus TM batteries
for storage and independent use
Electrical characteristics
Discharge end voltage
2.5 V
Discharge below 2.5 V at +25 °C and discharge below 2 V at −40 °C
may lead to an increase of the internal resistance.
Max. charge voltage
3.95 V
Shelf life
@ +25 °C
@ +60 °C
@ +85°C
in PulsesPlus TM batteries
10 years
7 years
≥ 1 year
used independently
3 years
4 weeks
1 week
Cycle life
to 1 % DOD1)
to 10 % DOD
to 100 % DOD
at 3.6 V
400000 cycles
40000 cycles
4000 cycles
at 3.9 V
100000 cycles
10000 cycles
1000 cycles
Temperature range
1)
DOD = depth of discharge
Overcharge above 3.95 V may
lead to capacity loss and/or an
increase of internal resistance.
Overcharge above 4.4 V may
lead to excessive internal
pressure. This may result in
explosion or rupture.
HLCs must not be charged
after a deep discharge below
2.5 Volts.
PDC16Eng
Transport
HLCs have passed the UN
transport tests. They contain
less than 0.3 g lithium equivalent and are not restricted
under international dangerous
goods regulations.
For more information on
classification and transport
regulations, please refer to
Tadiran’s technical notice:
www.tadiranbatteries.de/
regulations/
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
37
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› Delivering high current pulses
›› Up to 25 years lifetime and more
›› Wide operating temperature range
›› Low self discharge
HLC-1020
Performance Data
(Typical values in PulsesPlus TM batteries stored at +25 °C)
4.0
System
Version
Nominal voltage
Nominal capacity
3.8
HLC-1020(L)/T
20−1
20−1
3
1: 30 mA
2: 75 mA
3: 150 mA
3.2
0.1
1
10
102
Pulse duration / s
103
104
Maximum Pulse Width from 3.6 V to 2.8 V
1:
2:
3:
4:
5:
0.3
−40 °C
−20 °C
0 °C
+25 °C
+85 °C
0.2
3
0.1
4&5
2
7±1
1
3.17
0.0
0.01
7±1
0.1
1
HLC-1020(L)/TP
3.7±0.5 3.7±0.5
3.17
2
3.4
0.4
Ø 10.2±0.3
+
+
1
2.8
0.01
±0.3
HLC-1020(L)/S
3.6
3.0
Pulse amplitude / A
Ø 10.2
Voltage / V
Lithium Intercalated Compounds
HLC-1020
(HLC-1020L)
3.67 V / optional 3.9 V
45 As @ 3.67 V
(30 As @ 3.67 V)
70 As @ 3.9 V
(45 As @ 3.9 V)
Nominal current
15 mA
Max. continuous discharge current 250 mA
(150 mA)
Pulse current capability
750 mA
(500 mA)
Max. charge voltage
3.95 V
Max. charge current
8 mA
(6 mA)
Discharge end voltage
2.5 V
Cell impedance
max. 400 mΩ
(max. 600 mΩ)
Lithium content
0.01 g
Weight
4.2 g
For more data please refer to page 37.
Voltage during a Pulse at +25 °C
4.0
10
102
Pulse width / s
103
104
Pulse Voltage after 1 s
0.7±0.02
7.5
0.7±0.02
7.5
Voltage / V
3.8
3.6
3.4
1 2
1: 30 mA
2: 60 mA
3: 100 mA
3
3.2
3.0
2.8
−50 −35 −20 −5
4.0
10 25 40 55
Temperature / °C
70
85 100
Voltage Curve at +25 °C
Catalogue No.
HLC-1020/S
HLC-1020/T
HLC-1020/TP
HLC-1020L/S
HLC-1020L/T
HLC-1020L/TP
13 0 11021 02
13 0 11022 02
13 0 11027 02
13 0 13021 02
13 0 13022 02
13 0 13027 02
Standard
Tags
Polarized tags
Standard
Tags
Polarized tags
CAUTION:
Fire, explosion,
and severe burn hazard.
Do not disassemble, heat
above 100 °C, or incinerate.
Use as part of PulsesPlus™
battery only. Do not
charge above 3.95 V.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
3.6
3.4
3.2
3.0
2.8
2.6
0.01
38
15 mA discharge
0.1
1
10
Available capacity / As
102
103
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
Available Terminations
Open circuit voltage / V
3.8
›› Delivering high current pulses
›› Up to 25 years lifetime and more
›› Wide operating temperature range
›› Low self discharge
HLC-1520A
Performance Data
(Typical values in PulsesPlus TM batteries stored at +25 °C)
4.0
System
Nominal voltage
Nominal capacity
3.8
3.6
1.2
1:
2:
3:
4:
5:
Ø 14.5
Ø 14.5+0.2
0.7
7±1±0.02
0.8
0.6
2
0.0
0.01
3.17
3.17
4.0
0.1
1
Pulse Voltage after 1 s
3.4
1 2
1: 100 mA
2: 200 mA
3: 300 mA
3
3.2
2.8
−50 −35 −20 −5
4.0±0.5
4.0±0.5
10 25 40 55
Temperature / °C
70
85 100
Voltage Curve at +25 °C
3.8
0.7
0.7±0.02
Available Terminations
Catalogue No.
CAUTION:7.5
7.5
Fire, explosion,
and severe burn hazard.
Do not disassemble, heat
above 100 °C, or incinerate.
HLC-1520A/S
HLC-1520A/T
HLC-1520A/TP
13 0 11521 02
13 0 11522 02
13 0 11527 02
Use as part of PulsesPlus™
battery only. Do not
charge above 3.95 V.
±0.02
Open circuit voltage / V
3.7±0.5
3.7±0.5
104
3.0
7.5
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
103
3.6
4.0
Standard
Tags
Polarized tags
10
102
Pulse width / s
3.8
Voltage / V
±0.5
4.0
4.0±0.5
±0.5
4.0
±0.5
3.7
3.7±0.5
3.7±0.5
±0.02
0.7±0.02
0.7±0.02
0.2
0.2
4&5
3
0.4
1
HLC-1520/TP
0.2
0.2
104
−40 °C
−20 °C
0 °C
+25 °C
+85 °C
±1
+0.2
103
3.6
3.4
3.2
3.0
2.8
2.6
0.01
39
50 mA discharge
0.1
1
10
Available capacity / As
102
103
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
7
1
10
102
Pulse duration / s
0.2
4.0±0.5
3.7±0.5
21−1
21−1
Pulse amplitude / A
HLC-1520/T
0.1
Maximum Pulse Width from 3.6 V to 2.8 V
1.0
3.17
0.2
0.13
0.13
3
1: 100 mA
2: 250 mA
3: 500 mA
3.2
2.8
0.01
Ø 15.5−1
Ø 15.5−1
++
2
3.0
0.13
HLC-1520/S
Ø 14.5+0.2
1
3.4
21−1
+
Voltage / V
Lithium Intercalated Compounds
3.67 V, optional 3.9 V
140 As (39 mAh) @ 3.67 V
210 As (58 mAh) @ 3.9 V
Nominal current
25 mA
Max. continuous discharge current 500 mA
Pulse current capability
2000 mA
Max. charge voltage
3.95 V
−1
Ø 15.5
Max.
charge current
25 mA
Discharge end voltage
2.5 V
Cell impedance
max. 250 mΩ (@ 1 kHz, RT)
Lithium content
0.02 g @ 3.67 V
0.03 g @ 3.9 V
Weight
7.7 g
For more data please refer to page 37.
7±1
Voltage during a Pulse at +25 °C
›› Delivering high current pulses
›› Up to 25 years lifetime and more
›› Wide operating temperature range
›› Low self discharge
HLC-1530A
Performance Data
(Typical values in PulsesPlus TM batteries stored at +25 °C)
4.0
System
Nominal voltage
Nominal capacity
3.8
Voltage / V
Lithium Intercalated Compounds
3.67 V, optional 3.9 V
250 As (70 mAh) @ 3.67 V
380 As (105 mAh) @ 3.9 V
Nominal current
50 mA
Max. continuous discharge current 750 mA
Pulse current capability
3000 mA
Max. charge voltage
3.95 V
Max. charge current
50 mA
Discharge end voltage
2.5 V
Cell impedance
max. 140 mΩ (@ 1 kHz, RT)
Lithium content
0.02 g @ 3.67 V
0.05 g @ 3.9 V
Weight
10.3 g
For more data please refer to page 37.
3.6
1
2
3
3.4
1: 150 mA
2: 400 mA
3: 750 mA
3.2
3.0
2.8
0.01
HLC-1530/T
Ø 15.5−1
Ø 15.5−1
Pulse amplitude / A
2.0
HLC-1530/S
0.1
1
10
102
Pulse duration / s
103
104
Maximum Pulse Width from 3.6 V to 2.8 V
1:
2:
3:
4:
5:
1.5
−40 °C
−20 °C
0 °C
+25 °C
+85 °C
1.0
4&5
3
0.5
2
1
28−1
28−1
+
+
Voltage during a Pulse at +25 °C
0.13
0.13
7±1
7±1
0.0
0.01
3.17
3.17
4.0
HLC-1530/TP
Ø 14.5+0.2
Ø 14.5+0.2
0.1
1
10
102
Pulse width / s
103
104
Pulse Voltage after 1 s
0.2
0.2
0.7±0.02
0.7±0.02
Voltage / V
±0.5 ±0.5
4.04.0
±0.5 ±0.5
3.73.7
3.8
7.5
7.5
3.6
3.4
1 2
1: 150 mA
2: 300 mA
3: 500 mA
3
3.2
3.0
2.8
−50 −35 −20 −5
4.0
10 25 40 55
Temperature / °C
70
85 100
Voltage Curve at +25 °C
Catalogue No.
HLC-1530A/S
HLC-1530A/T
HLC-1530A/TP
13 0 11531 02
13 0 11532 02
13 0 11537 02
Use as part of PulsesPlus™
battery only. Do not
charge above 3.95 V.
Standard
Tags
Polarized tags
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
3.6
3.4
3.2
3.0
2.8
0.01
40
100 mA discharge
2.6
0.1
1
10
Available capacity / As
102
103
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
Available Terminations
CAUTION:
Fire, explosion,
and severe burn hazard.
Do not disassemble, heat
above 100 °C, or incinerate.
Open circuit voltage / V
3.8
›› Delivering high current pulses
›› Up to 25 years lifetime and more
›› Wide operating temperature range
›› Low self discharge
HLC-1550A
Performance Data
(Typical values in PulsesPlus TM batteries stored at +25 °C)
4.0
System
Nominal voltage
Nominal capacity
3.8
Voltage / V
Lithium Intercalated Compounds
3.67 V, optional 3.9 V
560 As (155 mAh) @ 3.67 V
850 As (240 mAh) @ 3.9 V
Nominal current
50 mA
Max. continuous discharge current 2000 mA
Pulse current capability
5000 mA
-1
Ø 15.5
Max.
charge
voltage
3.95 V
Max. charge current
100 mA
Discharge end voltage
2.5 V
Cell impedance
max. 100 mΩ (@ 1 kHz, RT)
Lithium content
0.05 g @ 3.67 V
0.10 g @ 3.9 V
Weight
20 g
7±1
For more data please refer to page 37.
4.0±0.5
3.7±0.5
7±1 ±0.02
0.7
7±1
Pulse amplitude / A
52-1
Ø 15.5
Ø 15.5-1
-1
-1
3
1: 300 mA
2: 750 mA
3: 1500 mA
3.2
0.1
1
10
102
Pulse duration / s
1:
2:
3:
4:
5:
3.0
2.5
4&5
1.5
3
1.0
2
0.5
1
0.0
0.01
4.0
HLC-1550/TP
104
−40 °C
−20 °C
0 °C
+25 °C
+85 °C
2.0
3.17
3.17
103
Maximum Pulse Width from 3.6 V to 2.8 V
3.5
3.17
HLC-1550/T
52-152
2
3.4
4.0
HLC-1550/S
0.2
0.13
0.13
1
2.8
0.01
0.13
Ø 14.5+0.2
3.6
3.0
+
+
+
Voltage during a Pulse at +25 °C
0.1
1
10
102
Pulse width / s
103
104
Pulse Voltage after 1 s
0.2
0.2
Voltage / V
7.5
0.7±0.02
0.7±0.02
3.4
1 2
3.2
2.8
−50 −35 −20 −5
4.0
10 25 40 55
Temperature / °C
70
85 100
102
103
Voltage Curve at +25 °C
3.8
7.5
CAUTION: 7.5
Available Terminations
Catalogue No.
HLC-1550A/S
HLC-1550A/T
HLC-1550A/TP
13 0 11551 02
13 0 11552 02
13 0 11557 02
Use as part of PulsesPlus™
battery only. Do not
charge above 3.95 V.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
1: 300 mA
2: 600 mA
3: 1000 mA
3
3.0
Fire, explosion,
and severe burn hazard.
Do not disassemble, heat
above 100 °C, or incinerate.
Standard
Tags
Polarized tags
3.6
3.6
3.4
3.2
3.0
2.8
2.6
0.01
41
200 mA discharge
0.1
1
10
Available capacity / As
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
0.7±0.02
0.7±0.02
0.7±0.02
±0.5±0.5
3.73.7
0.2
0.2
0.2
±0.5±0.5
4.04.0
Ø 14.5
Ø 14.5+0.2
+0.2
Open circuit voltage / V
±0.5
±0.5
±0.5
3.7
3.73.7
±0.5
±0.5
±0.5
4.0
4.04.0
3.8
Introduction
The TLM battery
The Tadiran TLM series, the
newest product innovation
from Tadiran Batteries, is
distinguished by its extremely
high power in the decisive
moment – when it really mat-
Outperforms competition
Compared to other commercial high rate lithium batteries, TLM batteries are superior
with respect to their voltage,
energy content, and temperature behaviour.
Smallest high
power battery
Figure 2 shows the behaviour
of TLM-1550HP under these
conditions. The battery was
subjected to accelerated ageing by storing it at +72 °C
for 3 weeks prior to the test.
Enduring low
impedance
For demanding applications
like the back-up battery in
eCall systems, the durability
of the battery in a wide temperature range is a decisive
factor. Especially two para-
Comparison TLM versus Li/MnO2
1
4.0
3.0
2.5
4
2.0
0
TLM-1550HP
discharge @ –20 °C
after 3 weeks storage @ +72 °C
1: 0.5 A for 3.75 ms every 6.25 ms, followed by
2: 2.5 A for 2.5 ms
3.5
2
Voltage / V
Voltage / V
3.5
CDMA Discharge after Accelerated Ageing
1 : TLM-1550/HP under 2 A @ +25 °C
2 : TLM-1550/HP under 1 A @ –20 °C
3 : CR123A under 2 A @ +25 °C
4 : CR123A under 1 A @ –20 °C
4.0
3.0
1
2
2.5
3
0.1
0.2
0.3
0.4
Capacity / Ah
0.5
2.0
0.6
0
5
10
15
Time / min
Figure 1: Comparison TLM versus Li/MnO2
Figure 2: CDMA Discharge after Accelerated Ageing
Advantages
High voltage 4.0 V
Very high pulse
current capability
Immediate response,
no passivation effect
Wide operating
temperature range
(−40 °C to +85 °C)
High reliability
(hermetic laser sealing,
glass-to-metal seal)
Outstanding storage
capability (up to 10 years)
Recognized safety (UL)
Very low self discharge
Easy health monitoring
during storage
Application in
eCall modules
One major application for
TLM batteries is the so-called
Autonomous Telematics Box or
Advanced Telematics Module
where the TLM battery serves
as the back-up battery for
eCall, the automatic emergency call system for cars in
Europe. The requirements for
this system include operation
under high pulse currents at
low temperature at any time up
to 10 years after installation.
Even under these severe conditions, an air time of more than
10 minutes is required. During this air time, the system
exchanges both car condition
and position data and voice
signals between the car and an
emergency call centre.
It was then cooled down to
−20 °C and discharged under
a simulated application load
profile comprising 2.5 A of
2.5 ms duration every 6.25 ms
on a basic load of 0.5 A. The
upper curve (1) shows the
voltage on the basic load
while the lower curve (2)
200
meters need to be sufficiently
low and stable: self discharge
and internal resistance. The
development of self discharge,
expressed as capacity loss over
storage time, is shown in the
data sheets of TLM batteries
on the following pages while
Figure 3 shows the develop-
Impedance Growth during Storage
TLM-1550HP
1: @ RT
2: @ +72 °C
150
100
2
1
50
0
0
500
1000
Time / days
1500
2000
Figure 3: Impedance Growth during Storage
shows the voltage during the
2.5 A pulses. The discharge
duration is clearly in excess
of 10 minutes. TLM-1550HP
is the smallest battery commercially available on the
market that can fulfil these
requirements.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
ment of the internal resistance
of TLM-1550HP over time at
two different storage temperatures. It remains within
the specified limits, even after
storage at +72 °C for 3 years.
PDC16Eng
Military version
TLM batteries are also available in a more robust version
for military applications.
For more information see
www.tadiranbatteries.de >>
products >> TLM batteries >>
Military version.
Figure 1 shows a comparison
with CR123A batteries. These
batteries have almost the
same volume as TLM-1550HP
and belong to the Lithium
Manganese Dioxide 3 Volt
system. Under a 2 Ampere discharge at room temperature,
they deliver almost the same
capacity as TLM-1550HP but
at much lower voltage. Under
1 Ampere discharge at −20 °C,
CR123A delivers almost no
capacity above 2 Volts, while
TLM-1550HP still delivers
more than 70 % of its nominal capacity.
Internal resistance / mΩ
ters! It stands for guaranteed
power even after long storage
or stand-by up to more than
10 years. Its outstanding
properties make it the ideal
back-up battery for the eCall
system, surgical instruments,
and other special applications.
42
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› High power 4 Volt cell
›› No voltage delay
›› Long shelf life
›› End of life indication capability
TLM-1520HP
Performance Data
Discharge Capability at +25 °C
(Typical values for batteries stored at +25 °C for one year)
1: 1.25 A
2: 0.5 A
3: 3.5 A, 1 s pulse every 10 s
4.0
Lithium Metal Oxide
4.0 V
135 mAh
12 mA
1.25 A
3.5 A
max. 250 mΩ
90 cm2
0.04 g
9g
3.2 cm3
−40 °C ... +85 °C
3.5
Voltage / V
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Cell impedance
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.0
1
2.5
2
3
2.0
0
5
10
Time / min
15
20
Temperature Behaviour
A High Energy version TLM-1520HE is also available.
For more information please refer to page 2 and Tadiran’s website.
1:
2:
3:
4:
5:
4.0
during 0.25 A discharge
Ø 15.5−1
Ø 15.5−1
3.0
4
5
3
2.5
2
1
21−1
21−1
2.0
0.13
0.13
Ø 14.5+0.2
Ø 14.5+0.2
7±1
7±1
0
50
Accumulated capacity loss1) / %
TLM-1520HP/TP
±0.5 ±0.5
3.73.7
0.2
0.2
0.7±0.02
0.7±0.02
25
50
75
100
Capacity / mAh
125
150
3.17
3.17
±0.5 ±0.5
4.04.0
+
+
3.5
TLM-1520HP/T
Voltage / V
TLM-1520HP/S
−40 °C
−30 °C
−20 °C
+22 °C
+72 °C
7.5
7.5
Ageing during Storage
1: +25 °C
2: +55 °C
3: +70 °C
40
3
2
30
20
1
10
1)
0
0
5
when tested at RT under 12 mA to 2.8 V
10
15
Time / years
20
25
Voltage Curve
4.0
Voltage / V
3.5
Catalogue No.
TLM-1520HP/S
TLM-1520HP/T
TLM-1520HP/TP
12 0 12521 02
12 0 12522 02
12 0 12527 02
Standard
Tags
Polarized tags
2.5
WARNING:
Fire, explosion,
and severe burn hazard. Do
not charge, disassemble,
heat above 100 °C,
incinerate, or short circuit.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
2.0
0
43
25
50
75
100
Capacity / mAh
125
150
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
Available Terminations
3.0
›› High power 4 Volt cell
›› No voltage delay
›› Long shelf life
›› End of life indication capability
TLM-1530HP
Performance Data
Discharge Capability at +25 °C
(Typical values for batteries stored at +25 °C for one year)
1: 2.5 A
2: 1.0 A
3: 6.5 A, 1 s pulse every 10 s
4.0
Lithium Metal Oxide
4.0 V
240 mAh
20 mA
2.5 A
6.5 A
max. 175 mΩ
160 cm2
0.08 g
11 g
4.4 cm3
−40 °C ... +85 °C
3.5
Voltage / V
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Cell impedance
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.0
1
2.5
2
3
2.0
0
5
10
Time / min
15
Temperature Behaviour
A High Energy version TLM-1530HE is also available.
For more information please refer to page 2 and Tadiran’s website.
4.0
1:
2:
3:
4:
5:
during 0.5 A discharge
TLM-1530HP/S
3.5
Voltage / V
TLM-1530HP/T
Ø 15.5–1
Ø 15.5–1
3.0
2
2.5
3
4
−40 °C
−30 °C
−20 °C
+22 °C
+72 °C
5
1
2.0
28–1
28–1
+
+
20
0.13
0.13
7±1
7±1
0
3.17
3.17
50
Accumulated capacity loss1) / %
TLM-1530HP/TP
±0.5 ±0.5
3.73.7
±0.5 ±0.5
4.04.0
Ø 14.5+0.2
Ø 14.5+0.2
0.2
0.2
0.7±0.02
0.7±0.02
7.5
7.5
50
100
150
200
Capacity / mAh
250
300
Ageing during Storage
1: +25 °C
2: +55 °C
3: +70 °C
40
3
2
30
20
1
10
1)
0
0
5
when tested at RT under 20 mA to 2.8 V
10
15
Time / years
20
25
Voltage Curve
4.0
Voltage / V
3.5
Catalogue No.
TLM-1530HP/S
TLM-1530HP/T
TLM-1530HP/TP
12 0 12531 02
12 0 12532 02
12 0 12537 02
Standard
Tags
Polarized tags
2.5
WARNING:
Fire, explosion,
and severe burn hazard. Do
not charge, disassemble,
heat above 100 °C,
incinerate, or short circuit.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
2.0
0
44
50
100
150
200
Capacity / mAh
250
300
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
Available Terminations
3.0
›› High power 4 Volt cell
›› No voltage delay
›› Long shelf life
›› End of life indication capability
TLM-1550HP
Performance Data
Discharge Capability at +25 °C
(Typical values for batteries stored at +25 °C for one year)
1: 5 A
2: 2 A
3: 15 A, 1 s pulse every 10 s
4.0
Lithium Metal Oxide
4.0 V
550 mAh
50 mA
5A
15 A
max. 100 mΩ
360 cm2
0.18 g
20 g
8 cm3
−40 °C ... +85 °C
3.5
Voltage / V
System
Nominal voltage
Nominal capacity
Nominal current
Max. continuous discharge current
Pulse current capability
Cell impedance
Anode surface area
Lithium content
Weight
Volume
Temperature range
3.0
1
2
2.5
3
2.0
0
5
10
Time / min
15
20
Temperature Behaviour
A High Energy version TLM-1550HE is also available.
For more information please refer to page 2 and Tadiran’s website.
4.0
during 1 A discharge
3.5
TLM-1550HP/Z2/T
Voltage / V
TLM-1550HP/S
Ø 15.5-1
Ø 15.5-1
−40 °C
−30 °C
−20 °C
+22 °C
+72 °C
3.0
2
2.5
+
+
1:
2:
3:
4:
5:
3
4
5
1
52-152-1
2.0
0.13
0.13
0
7±1
7±1
3.17
3.17
50
±0.5±0.5
4.04.0
±0.5±0.5
3.73.7
0.2
0.2
Accumulated capacity loss1) / %
TLM-1550HP/Z2/TP
Ø 14.5+0.2
Ø 14.5+0.2
100
0.7
0.7±0.02
±0.02
7.5
7.5
200
300
400
Capacity / mAh
500
600
Ageing during Storage
1: +25 °C
2: +55 °C
3: +70 °C
40
3
2
30
20
1
10
1)
0
0
5
when tested at RT under 50 mA to 2.8 V
10
15
Time / years
20
25
Voltage Curve
4.0
Voltage / V
3.5
Catalogue No.
TLM-1550HP/S
TLM-1550HP/Z2/T
TLM-1550HP/Z2/TP
12 0 12551 02
12 1 12552 02
12 1 12557 02
Standard
Tags*
Polarized tags*
* with PTC SRP 200
2.5
WARNING:
Fire, explosion,
and severe burn hazard. Do
not charge, disassemble,
heat above 100 °C,
incinerate, or short circuit.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
2.0
0
45
100
200
300
400
Capacity / mAh
500
600
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
Available Terminations
3.0
Introduction
Characteristics
Dimensions
Capacity
Power:
@ +25 °C
@ –20 °C
Temperature range:
Storage
Discharge
Charge
Self discharge
Operating life
18650 Li-Ion
TLI-1550A
Ø 18 mm x 64 mm Ø 15 mm x 50 mm
0.4 Ah
3.2 Ah
18 W
>6W
18W
<3W
Table 1 shows a comparison
of a standard lithium ion cell
18650 with the TLI-1550. It
can be seen that the characteristics of the TLI series are
superior in terms of power,
self-discharge and operating
temperature range.
200
150
100
2
2.5
50
2.0
0
Time
Figure 1: Charging principle CCCV. Example for TLI-1550
Figure 1 shows the constant
current/constant voltage
(CCCV) charging principle
which is recommended for
the TLI series. The battery
is charged with a constant
current until the maximum
voltage is reached. Afterwards,
the charging current is decreased to maintain constant
voltage. Charging may be
discontinued when a predefined end-of-charge current is
reached. With the maximum
current, charging takes approximately 6.5 hours in the
temperature range between
–20 °C and +50 °C. In the
extended temperature range
between –40 °C and +85 °C the
maximum charging current is
five times lower, resulting in
a five times longer charging
time.
TLI in eCall applications
The TLI battery ensures constant power supply even under
high current pulses. This is
required for applications like
bidirectional wireless communication modules. One major
application for TLI batteries is
the so-called Autonomous
Telematics Box or Advanced
Telematics Module where
the TLI battery serves as the
back-up battery for eCall, the
automatic emergency call
system for cars in Europe. The
requirements for this system
include operation under high
pulse currents at low temperature at any time up to 10
years after installation. Even
under these severe conditions,
an air time of more than 10
Figure 2 shows the behaviour
of TLI-1550 in a typical eCall
application after an ageing
period of one month at 72 °C.
The GSM transmission profile
of the application requires a
2 A pulse for the duration of
577 µs followed by a 150 mA
pulse for 4.6 ms. This load
alternation is continuously
repeated. Even at a temperature of –40 °C a TLI-1550 cell
ensures an air time of more
than 15 minutes.
Approval by Tadiran
The design of the following
items should be approved by
Tadiran:
Implementation of the
protection circuit against
overcharge, e.g. by limitation of the charging voltage
and charging current to
the values given in the
individual data sheets
Implementation of
low voltage protection
against deep discharge
Protection
In order to ensure a high level
of safety, TLI cells 1530 and
1550 should be protected by
a PTC either on the battery or
on the PC-board. Recommended PTC types include SRP120
and SRP200, respectively, as
follows: SRP120 limits the
discharge current to 1.2 A
and SRP200 to 2 A. In special
cases cells can be used without PTC.
TLI batteries have no integrated overcharge protection. The protection circuit
should be designed by the
customer and be approved by
Tadiran. Please refer to the TLI
guidelines posted on Tadiran’s
website under products >>
TLI-batteries.
GSM Discharge Curves
Voltage / V
Characteristics
Wide operating temperature (– 40 °C to + 85 °C)
Short time storage up
to + 90 °C possible
Ability to deliver high
current pulses (up to 5 A)
Low self-discharge (less
than 5 % per year)
Up to 5 times extended
cycle life (5000 full charge/
discharge cycles)
Long operating
time (10 years)
Charging possible at
extreme temperatures
(10h-rate)
Hermetically sealed cell
(glass-to-metal seal)
Certified safety (UL)
Easy monitoring of cell
fitness during storage
3.0
–40 °C to +85 °C
–40 °C to +85 °C
–40 °C to +85 °C
< 5 % per year
10+ years
Current / mA
By contrast, TLI series batteries utilize technology found in
Tadiran’s patented hybrid layer capacitor (HLC). Tadiran’s
technology has been fieldproven in millions of cells to
deliver 25 years and more
service life. TLI series batteries modify this technology to
deliver reliable, long-term
performance under extreme
environmental conditions.
Voltage / V
–20 °C to +60 °C
Standard rechargeable lithium
ion cells have inherent draw–20 °C to +60 °C
backs which have an impact
±0 °C to +45 °C
on long term applications.
20 % per year
These include short operating
5 years
life (maximum 5 years), low
maximum cycle life (1000 cy- Table 1: Comparison of TLI-1550 versus
a standard lithium ion cell 18650
cles), high self-discharge (up
to 60 % per year), and limited
Charging Principle CCCV
temperature range (0 °C to
60 °C) with no possibility
4.0
of charging at low and high
1
1: Voltage
temperatures.
3.5
2: Current
minutes is required. During this air time,
the system exchanges both car
condition and position data
and voice signals between the
car and an emergency call
centre.
4.0
1: 2.0 A / 577 µs
2: 150 mA / 4.6 ms
3.5
1
2
+20 °C
–10 °C
–30 °C
–40 °C
2
1
3.0
2
1
2.5
2
1
2.0
20
15
25
30
35
Time / min
Figure 2: Discharge behaviour of TLI-1550 under the GSM profile
after storage at 72 °C for one month
0
5
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
10
46
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
TLI-Battery
The TLI series is specifically designed for long-term
use in harsh environments.
It represents an important
breakthrough in rechargeable lithium-ion battery
technology.
›› RECHARGEABLE
›› Up to 5000 cycles
›› Extremely low self discharge rate
›› Charging possible at extreme temperatures
TLI-1020A
Performance Data
Discharge Curve at 25 °C
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Lithium Intercalated Compounds
Nominal voltage
4V
Max. capacity
25 mAh
Max. continuous discharge current 160 mA
Pulse current capability
400 mA
Discharge end voltage
2.5 V
Max. charge voltage
4.1 V
Max. charge current
8 mA
1.6 mA
Temperature range
–20 °C ... +50 °C
– 40 °C ... +85 °C
Cell impedance @ 1 kHz, RT
max. 600 mΩ
Nominal energy
max. 0.09 Wh
Weight
4.2 g
For more information please refer to page 46.
1: 400 mA
2: 200 mA
3: 100 mA
4: 10 mA
Voltage / V
3.5
3.0
1
2 3
4
2.5
2.0
0
5
10
15
20
Capacity / mAh
25
Discharge Curve at 100 mA
4.0
TLI-1020A/S
Ø 10.2±0.3
1: –40 °C
2: –30 °C
3: –20 °C
4:
0 °C
5: +22 °C
TLI-1020A/T
Voltage / V
3.5
20−1
Ø 10.2±0.3
3.0
2.5
20−1
+
+
1
7±1
2
3
4
5
2.0
3.17
7±1
0
5
10
TLI-1020A/TP
3.7±0.5 3.7±0.5
3.17
30
0.7±0.02
7.5
0.7±0.02
7.5
Capacity / mAh
40
15
20
Capacity / mAh
25
30
Cycling Performance
30
20
10
0
Catalogue No.
TLI-1020A/S
TLI-1020A/T
TLI-1020A/TP
13 2 11021 02
13 2 11022 02
13 2 11027 02
Standard
Tags
Polarized tags
1000
2000
Cycles
3000
4000
Warning:
Fire, explosion,
and severe burn hazards.
Do not disassemble, heat
above 100 °C, short circuit,
incinerate or expose
contents to water.
PDC16Eng
Available Terminations
0
Do not charge above 4.1 V.
Please refer to TLI-guidelines.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
47
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› RECHARGEABLE
›› Up to 5000 cycles
›› Extremely low self discharge rate
›› Charging possible at extreme temperatures
TLI-1520A
Performance Data
Discharge Curve at 25 °C
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Lithium Intercalated Compounds
Nominal voltage
4V
Max. capacity
90 mAh
Max. continuous discharge current 500 mA
Pulse current capability
1.25 A
Dischage end voltage
2.5 V
Max. charge voltage
4.1 V
Max. charge current
25 mA
5 mA
Temperature range
–20 °C ... +50 °C
– 40 °C ... +85 °C
Cell impedance @ 1 kHz, RT
max. 250 mΩ
Nominal energy
max. 0.3 Wh
Weight
9g
For more information please refer to page 46.
1: 1250 mA
2: 625 mA
3: 250 mA
4: 50 mA
Voltage / V
3.5
1
3.0
2
3
4
2.5
2.0
0
20
40
60
80
Capacity / mAh
120
Discharge Curve at 500 mA
4.0
1:
2:
3:
4:
5:
TLI-1520A/T
TLI-1520A/S
3.5
21−1
21−1
Voltage / V
Ø 15.5−1
Ø 15.5−1
+
+
100
−40 °C
−30 °C
−20 °C
0 °C
+22 °C
5
3.0
4
3
2
2.5
1
7
7±1
2.0
±1
0.13
0.13
Ø 14.5+0.2
Ø 14.5+0.2
0
3.17
3.17
20
40
60
80
Capacity / mAh
100
120
TLI-1520A/TP
0.2
0.2
0.7±0.02
0.7±0.02
Capacity / mAh
±0.5 ±0.5
3.73.7
±0.5 ±0.5
4.04.0
120
7.5
7.5
Cycling Performance
90
60
30
0
Catalogue No.
TLI-1520A/S
TLI-1520A/T
TLI-1520A/TP
13 2 11521 02
13 2 11522 02
13 2 11527 02
Standard
Tags
Polarized tags
1000
2000
Cycles
3000
4000
Warning:
Fire, explosion,
and severe burn hazards.
Do not disassemble, heat
above 100 °C, short circuit,
incinerate or expose
contents to water.
PDC16Eng
Available Terminations
0
Do not charge above 4.1 V.
Please refer to TLI-guidelines.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
48
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› RECHARGEABLE
›› Up to 5000 cycles
›› Extremely low self discharge rate
›› Charging possible at extreme temperatures
TLI-1530A
Performance Data
Discharge Curve at 25 °C
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Lithium Intercalated Compounds
Nominal voltage
4V
Max. capacity
150 mAh
Max. continuous discharge current 1 A
Pulse current capability
2.5 A
Dischage end voltage
2.5 V
Max. charge voltage
4.1 V
Max. charge current
50 mA
10 mA
Temperature range
–20 °C ... +50 °C
– 40 °C ... +85 °C
Cell impedance @ 1 kHz, RT
max. 175 mΩ
Nominal energy
max. 0.5 Wh
Weight
10 g
For more information please refer to page 46.
1: 2500 mA
2: 1250 mA
3: 500 mA
4: 50 mA
Voltage / V
3.5
1
3.0
2.5
2.0
0
25
50
75
100
Capacity / mAh
4.0
1:
2:
3:
4:
5:
TLI-1530A/T
3.5
Voltage / V
Ø 15.5−1
Ø 15.5−1
4
3.0
28−1
28−1
0.13
0.13
−40 °C
−30 °C
−20 °C
0 °C
+22 °C
5
3
2
2.5
7±1
7±1
150
Discharge Curve at 1 A
TLI-1530A/S
+
+
125
1
2.0
3.17
3.17
0
25
50
75
100
Capacity / mAh
125
150
TLI-1530A/TP
Ø 14.5
Ø 14.5+0.2
+0.2
0.7±0.02
0.7±0.02
Capacity / mAh
0.2
0.2
±0.5 ±0.5
4.04.0
±0.5 ±0.5
3.73.7
160
7.5
7.5
Cycling Performance
120
80
40
0
Catalogue No.
TLI-1530A/S
TLI-1530A/T
TLI-1530A/TP
13 2 11531 02
13 2 11532 02
13 2 11537 02
Standard
Tags
Polarized tags
1000
2000
Cycles
3000
4000
Warning:
Fire, explosion,
and severe burn hazards.
Do not disassemble, heat
above 100 °C, short circuit,
incinerate or expose
contents to water.
PDC16Eng
Available Terminations
0
Do not charge above 4.1 V.
Please refer to TLI-guidelines.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
49
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› RECHARGEABLE
›› Up to 5000 cycles
›› Extremely low self discharge rate
›› Charging possible at extreme temperatures
TLI-1550A
Performance Data
Discharge Curve at 25 °C
(Typical values for batteries stored at +25 °C for one year)
4.0
System
Lithium Intercalated Compounds
Nominal voltage
4V
Max. capacity
330 mAh
Max. continuous discharge current 2 A
Pulse current capability
5A
Discharge end voltage
2.5 V
Max. charge voltage
4.1 V
Max. charge current
100 mA
20 mA
Temperature range
–20 °C ... +50 °C
– 40 °C ... +85 °C
Cell impedance @ 1 kHz, RT
max. 100 mΩ
Nominal energy
max. 1.0 Wh
Weight
20 g
For more information please refer to page 46.
1:
2:
3:
4:
Voltage / V
3.5
1
3.0
2
3
4
2.5
2.0
0
60
120
180
240
Capacity / mAh
3.5
Voltage / V
Ø 15.5-1
Ø 15.5-1
+
+
4
3.0
52-152-1
5
6
7
3
2
2.5
0.13
0.13
360
1: –40 °C
2: –30 °C
3: –20 °C
4: –10 °C
5:
0 °C
6: +25 °C
7: +80 °C
TLI-1550A/Z2/T
7±1
7±1
300
Discharge Curve at 2 A
4.0
TLI-1550A/S
5.0 A
2.5 A
1.0 A
0.1 A
1
2.0
3.17
3.17
0
60
120
180
240
Capacity / mAh
300
360
TLI-1550A/Z2/TP
400
0.7±0.02
0.7±0.02
Capacity / mAh
0.2
0.2
350
±0.5±0.5
4.04.0
±0.5±0.5
3.73.7
Ø 14.5+0.2
Ø 14.5+0.2
Cycling Performance
7.5
7.5
300
250
200
150
100
50
0
Catalogue No.
TLI-1550A/S
TLI-1550A/Z2/T
TLI-1550A/Z2/TP
13 2 11551 02
13 3 11552 02
13 3 11557 02
Standard
Tags
Polarized tags
1000
2000
Cycles
3000
4000
Warning:
Fire, explosion,
and severe burn hazards.
Do not disassemble, heat
above 100 °C, short circuit,
incinerate or expose
contents to water.
PDC16Eng
Available Terminations
0
Do not charge above 4.1 V.
Please refer to TLI-guidelines.
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
50
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
Safety &
Transport Regulations
UL-recognition
Tadiran Lithium Batteries are
recognized by UL under file
MH 12827, please refer to
UL ONLINE CERTIFICATIONS
DIRECTORY for further information. The following text or
a modified version thereof
appears on each battery:
Protection against charging
Whenever lithium batteries are not the single power
source in a circuit the following measures are recommended by the Underwriters
Laboratories:
The battery should not be connected in series with an electrical power source that would
increase the forward current
through the battery.
The circuit shall include one of
the following:
WARNING:
Fire, explosion, and severe
burn hazard. Do not recharge,
disassemble, heat above
100 °C, incinerate, or expose
contents to water.
A. Two suitable diodes in
series with the battery to
prevent any reverse (charging) current. The second
diode provides protection
if the other one fails; or
Classification of
lithium batteries
Lithium metal batteries
are dangerous goods, UN No.
3090. Lithium ion batteries
are dangerous goods, UN No.
3480. Table 2 indicates which
Tadiran Lithium cells are
exempted from the dangerous
goods regulations and which
are not.
In air transport, exemptions
are limited.
System
Size
Lithium
Thionyl
Chloride
(LTC)
1 ⁄10
C
1 ⁄10
D
For more information on
classification and transport
regulations, please refer to
Tadiran’s technical notice:
www.tadiranbatteries.de/
regulations/
UN tests
Table 2 also shows the status of UN-tests for Tadiran
Lithium Batteries according to the UN Handbook of
Tests and Criteria, part III,
sub-section 38.3. Regarding
Tadiran Lithium Batteries not
listed in table 2, please apply to Tadiran Batteries for a
confirmation.
TLI batteries
Type
IR max
SL-350
SL-360
SL-361
SL-550
SL-560
SL-561
SL-750
SL-760
SL-761
SL-840
SL-850
SL-860
SL-861
SL-886
SL-889
SL-2770
SL-2780
SL-2790
SL-2870
SL-2880
TLM-1520HP
TLM-1530HP
TLM-1550HP
TLM-1520HE
TLM-1530HE
TLM-1550HE
15 mA
50 mA
20 mA
15 mA
50 mA
15 mA
15 mA
50 mA
20 mA
15 mA
15 mA
50 mA
REACH and RoHS
20 mA
All Tadiran cell are compliant
25 mA
with REACH regulation and
20 mA
RoHS directive.
15 mA
50 mA
100 mA
15 mA
50 mA
100 mA
100 mA
100 mA
25 mA
50 mA
100 mA Table 1: Maximum reverse current
Protection against forced
discharge
Forced discharge of a cell can
occur when it is connected in
series with other cells. A bypass diode should be provided
in parallel with each cell in a
series connection. The effect
of a by-pass diode is that current passes through the diode
if a cell has been discharged,
preventing forced discharge.
Exempted1) Lithium
UN Test
content [g] passed
Type
SL-840
TLH-2450
D
TL-2450
UN Number
Yes
0.13
Yes
3090/91
Yes
0.18
Yes
3090/91
SL-786
SL-886
Yes
0.3
Yes
3090/91
SL-789
SL-889
Yes2)
0.5
Yes
3090/91
1 ⁄2
AA
SL-350
SL-550
SL-750
SL-850
Yes2)
0.35
Yes
3090/91
2 ⁄3
AA
SL-361
SL-561
SL-761
SL-861
Yes2)
0.5
Yes
3090/91
SL-360
SL-560
SL-760
SL-860
Yes2)
0.65
Yes
3090/91
C
SL-2770
SL-2870
No
2.5
Yes
3090/91
D
SL-2780
SL2880
No
5
Yes
3090/91
DD
1 ⁄2
AAA
SL-2790
No
10
Yes
3090/91
HLC-1020 (3.67 V and 3.9 V)
Yes
0.01
Yes
3090/91
1 ⁄2
AA
HLC-1520 (3.67 V)
Yes
0.02
Yes
3090/91
2 ⁄3
AA
HLC-1530 (3.67 V)
Yes
0.02
Yes
3090/91
AA
1 ⁄2
AA
HLC-1550 (3.67 V)
Yes
0.05
Yes
3090/91
HLC-1520 (3.9 V)
Yes
0.03
Yes
3090/91
2 ⁄3
AA
HLC-1530 (3.9 V)
Yes
0.05
Yes
3090/91
AA
1 ⁄2
AA
HLC-1550 (3.9 V)
Yes
0.10
Yes
3090/91
TLM-1520HP
Yes
0.04
Yes
3090/91
2 ⁄3
AA
TLM-1530HP
Yes
0.08
Yes
3090/91
AA
1 ⁄2
AA
TLM-1550HP
Yes
0.18
Yes
3090/91
TLM-1520HE
Yes
0.11
Yes
3090/91
2 ⁄3
AA
TLM-1530HE
Yes
0.20
Yes
3090/91
AA
1 ⁄2
AAA
TLM-1550HE
Yes2)
Yes
0.44
< 0.3 Wh
Yes
TLI-1020
3090/91
3480/81
AA
TLM batteries
In addition to this UL requirement, which gives the safety
limits, Tadiran Batteries recommend to limit the reverse
(charging) current to values
below 10 µA. This will ensure
that service life is not affected.
BEL
1 ⁄6
Hybrid Layer
Capacitors
(HLC)
B. A blocking diode or the
equivalent to prevent
any reverse (charging)
current and a resistor to
limit current in case of a
diode failure. The resistor
should be sized to limit
the reverse (charging)
current to the maximums
IR max shown in table 1.
Yes
1 ⁄2
AA
TLI-1520
Yes
< 0.8 Wh
Yes
3480/81
2 ⁄3
AA
TLI-1530
Yes
< 1.2 Wh
Yes
3480/81
< 2.8 Wh
3480/81
Yes
Yes
if conditions mentioned in Tadiran’s technical notice are fulfilled
2) see also IATA DGR under UN 3090 / PI 968 / Table 968-II
AA
TLI-1550
Table 2: Classification of Tadiran Lithium Batteries
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
1)
51
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC16Eng
Standards
General safety recommendations for lithium batteries
have been published in the
standards UL 1642 and IEC
60086-4.
Tadiran Lithium Batteries – Applications
Military
Emergency Power
supply for UAVs
Fuzes
Gas masks
Guidance systems
Night vision goggles
Targeting devices
Ejection seats
High end consumer
Diving computers
Set top boxes
Sports electronics
Utility Metering
Automatic meter reading (AMR)
Electricity, gas, water,
heat, calorimeters
Heat cost allocators
Prepayment meters
Communication modules
Smart electricity meters
with a GSM module
Alarm and security systems
Smoke detectors
Wireless alarm systems
PIR detectors
Cash transport and
asset protection systems
Offender monitoring systems
Airbags
Automatic collision
devices
Belt tensioners
Brake controllers
Communication modules
Digital tachographs
Doors / latches
Engine controllers
In-car computers
Stolen vehicle
recovery systems
Telematics / eCall
Tyre pressure
monitoring systems
Beacons
Buoys
Life jacket lights
Oil drilling / MWD
Seismic sensors
Underwater
positioning systems
Off-shore
Defibrillators
Dispensers
Implantable devices
Infusion pumps
Surgical instruments
Electronic scales
Gambling machines
Taximeters
Vending machines
Cash machines
Point of sale terminals
Telephone
exchange boards
Instrumentation
Office automation
Your Distributor
Automotive
Process automation
Wireless sensor networks
Controllers
Fault detectors
Industrial PCs
Process logic control
Industrial automation
Lithium Thionyl Chloride (LTC) Batteries
PulsesPlus TM Batteries
Tadiran Lithium Metal Oxide (TLM) Batteries
Tadiran Lithium Ion (TLI) Batteries
PDC16Eng
Medical
Tracking
Animals
Corrosion
Data loggers
Electronic toll collection
On-board units
Personal
Pipelines
Railways
Trucks, containers, trailers
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
Download