North American Catalog CAT: MINI 2G-07 PUBLISHED: 07/2007

advertisement
CAT: MINI 2G-07
PUBLISHED: 07/2007
North American Catalog
SALES ORGANIZATION
Who are we? HPI develops and manufactures hydraulic products and systems based on the gear
pump technology. Over 500 people are employed in both sites in Chennevieres (Paris surroundings)
and Blois (Val de Loire). As a subsidiary of the Koyo Group (25000 employees all over the world), HPI
is provided with first range development and testing capacities, thus conforming to an international
quality system of reference.
HPI is supported by a subsidiary in North America and a network of over 50 distributors in France
and throughout the world. This network offers our customers a daily local service, thus ensuring a
maximum reactivity. Whenever needed, each member of our network can rely on the resources and
structures of HPI in order to meet its customers requirements.
JAPAN
JAPON
FRANCE
FRANCE
CANADA
CANADA
U.S.A
ETATS - UNIS
UNITED KINGDOM
ROYAUME UNI
SWEDEN
SUEDE
DENMARK
DANEMARK
SPAIN
ESPAGNE
BELGIUM
BELGIQUE
FINLAND
FINLANDE
NETHERLANDS
PAYS - BAS
NORWAY
NORVEGE
SWITZERLAND
SUISSE
AUSTRALIA
AUSTRALIE
NEW - ZEALAND
NOUVELLE - ZELANDE
AUSTRIA
AUTRICHE
MAROCCO
MAROC
HUNGARY
HONGRIE
GERMANY
ALLEMAGNE
ITALY
ITALIE
LEBANON
LIBAN
Aeronautics - Military applications
Material Handling
Lifting systems for all
stationary (AC) or mobile
(DC) handling equipment.
Agricultural Machinery
Tractor lifting systems and auxillary
functions, harvest toppers, scrub
clearing machines...
High tech pumps and electro-pump
sets used for civil and military
applications such as helicopters,
fighters, military vehicles...
Trucks - Coaches - Buses
Power assisted steering.
Hydrostatic transmission for
hydraulic or electro-hydraulic driven
cooling system
Public works and Road Maintenance
Hydraulic systems for excavators,
loaders, road rollers, garbage
dumpers, snowploughs...
TABLE OF CONTENTS
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
Page
GENERAL UNIT COMPOSITION
4
SELECTION / INSTALLATION GUIDELINES
5
CODIFICATION
DIRECT CURRENT
ALTERNATING CURRENT
6
7
PERFORMANCE CHARACTERISTICS
DIRECT CURRENT
DS: 1,3 kW 12VDC
DS: 1,5 kW 24VDC
BK: 2,1 kW 12VDC
BK: 2,2 kW 24VDC COMPOUND
BS: 2,2 kW 24VDC
CI: 3,0 kW 24VDC
ALTERNATING CURRENT
SINGLE PHASE 115/230V
THREE PHASE 208-230/460V
THREE PHASE 575V
AIR MOTOR
2 HP, 4 HP, 5 HP
8
9
10
11
12
13
14
14
14
15
RESERVOIRS
PLASTIC
ALUMINIUM, STEEL
MOUNTING ORIENTATION
16
17
18, 19
VALVE MOUNTING ACCESSORIES & DIMENSIONAL INFO
20 - 27
SPECIFICATIONS
POPPET VALVES:
VNF (normally closed)
VNO (normally open)
VLB (double lock)
PROPORTIONAL VALVES
DO3 VALVES
2 BUTTON WIRELESS REMOTE CONTROL
REPLACEMENT PARTS
ALTERNATING / DIRECT CURRENT
MINI POWER - PACKS
MINI CENTRALES
2G
-3-
28
28
28
29
30
30
31
UNIT COMPOSITION
COMPOSITION
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
Alternating Current Motor
Moteur à Courant Alternatif
Direct Current Motor
Moteur à Courant Continu
Relay
Relais
Coupling Set
Noix d'accouplement
Coupling
Noix
Adjustable Relief Valve
Limiteur de pression réglable
Mini - power pack support
Support Mini - centrale
Check valve
Clapet Anti - Retour
5
Accessory Block
2
3
4
1
6
Return Port
Orifice Retour
Pressure Port
Orifice Pression
Pump
Pompe
Cartridge valve
Electro valve à clapet pilote
Outlet piping
Tuyauterie Retour
Suction piping
Tuyauterie Aspiration
Flow restrictor
Limiteur de débit interne
Strainer
filtre
7. Collerette
Collerette
Reservoirs
Réservoirs
Filler breather cap
Bouchon de remplissage
avec filtre
Clip
Couper
Clamp Set
MINI POWER - PACKS
MINI CENTRALES
Filler Elbow
2G
-4-
Hydroperfect Intl. Inc.
SELECTION / INSTALLATION GUIDELINES
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
Selection Guidelines
Direct Current Models.
Based upon the flow and pressure requirements identify a motor and pump combination that will deliver the required
performance. Attention should be paid to the duty ratings as well as the current draw to ensure it falls within acceptable levels.
Alternating Current Models.
Based upon the flow and pressure requirements select a pump that is capable of providing the necessary flow and
pressure. It is generally recommended that the 3450 RPM motors are used. Once the pump has been identified it
will be necessary to calculate the required HP to drive the pump. Refer to the “Common Calculations and Conversion factors” area.
Selecting a Reservoir.
In single acting applications it is generally recommended to use a reservoir size that is at least 25% larger than the
total system oil capacity. In continuous duty applications several factors must be taken into consideration, most
importantly the reservoir must be sized to provide sufficient oil cooling.
Selecting Control Valves.
The final step in constructing the powerpack is to determine the valve combination that will be required for controlling
all the actuators. It should be noted that valve combinations may be created by using two or more different valves
and/or blocks. For applications that are not listed in this catalog please contact an HPI representative.
Installation Guidelines
Electrical Motor Connections.
The electric motor should be wired for CW rotation as per the wiring label. All electrical connections should be made
using the appropriate gauge wire based on the motor amp draw. It is common for a motor to see two to three times
its rated current draw for a few seconds while starting up under load.
Electrical Valve Connections.
Attention should be paid as to the type of connector that is supplied with the valve coils. HPI uses both straight
voltage and rectified voltage coils. AC coils that require rectified connectors are usually marked as “VRAC” (Voltage
Rectified Alternating Current.)
Hydraulic Fluid.
In General HPI recommends a high performance mineral based hydraulic fluid with a viscosity of 30 to 40 cSt at 40’C
be used. Ethylene Glycol and Phostate Ester fluids are NOT to be used with HPI products. For fire resistant hydraulic fluids; only some polyol ester based fluids may be appropriate.
Adjusting the Relief Valve.
The relief valve may be adjusted to increase or decrease the maximum system pressure. This adjustment will only
affect the pressure setting and will have no direct effect on the flow of the pump. Turning the adjustment screw
clockwise will increase the pressure, turning counterclockwise will decrease the pressure.
MINI POWER - PACKS
MINI CENTRALES
2G
-5-
DIRECT CURRENT
2
GENERATION
0,12 Cubic / inch
0,18 Cubic / Inch
0,24 Cubic / Inch
0,30 Cubic / Inch
0,36 Cubic / Inch
2 cc / rev
3 cc / rev
4 cc / rev
5 cc / rev
6 cc / rev
TS
TANG SHAFT, WITH RELAY ( >150 amp)
VNF
12
24VDC
14
24VAC
15
48VAC
17
115VAC
11
230VAC
13
AIR PILOT 19
0.53 Gal
0.66 Gal
0.79 Gal
1.05 Gal
1.32 Gal
1.32 Gal
2,0 L
2,5 L
3,0 L
4,0 L
5,0 L
5,0 L
NO RESERVOIR
1,5 L
0.40 Gal
TANKS
12VDC
X
E
A
H
B
S
C
R
VNO
22
24
25
27
21
23
29
XX
Cartridge valves
12 L
34 L
10 L
15 L
6,3 L
7,5 L
6,0 L
6,0 L
3.17 Gal
8.98 Gal
2.64 Gal
3.96 Gal
1.66 Gal
1.98 Gal
1.58 Gal
1.58 Gal
Z
U
G
K
D
L
Ds
Ms
N
S
2
3
TR
11.6 Gal
18.5 Gal
5.28 Gal
7.92 Gal
1.71 Gal
3.17 Gal
*
Qa
Da
La
Ma
Na
Oa
Ya
VNF = NORMALLY CLOSED. <20L/M
VNF2G = NORMALLY CLOSED. <10L/M (no override!)
VNO = NORMALLY OPEN.
VLB = DOUBLE LOCK.
CT3 - 4/3 WAY, TANDEM CENTRE.
CT2 = 4/2 WAY.
20
40
PROPORTIONAL VALVE 10L/MIN 90
PROPORTIONAL VALVE 20L/MIN 91
SPECIAL
**
B
MANUAL LEVER VALVE, 2 WAY
3 WAY WITH FREEFLOW
2
12 L
3.17 Gal
SPECIAL
44 L
70 L
20 L
30 L
6,5 L
12 L
CT2
72
74
75
77
71
73
4 way
VLB VNF2G CT3
42
32
52
44
34
54
45
35
55
47
37
57
41
31
51
43
33
53
39
2 way
NONE, PORTS BLOCKED
VALVES - MOUNTED ON PORTS 3 & 4
TX
TR
1
2
3
4
5
6
TANG SHAFT, NO RELAY
TANG SHAFT, WITH RELAY ( <150 amp)
SHAFT TYPE / RELAY
0,06 Cubic / Inch
1 cc / rev
***
000
DS1
BK1
24 Vdc
DS2
24 Vdc (Compound) BK2
24 Vdc
BS2
24 Vdc
CI2
12 Vdc
12 Vdc
PUMP CAPACITY
SPECIAL
2,2 kW
3,0 kW
1,5 kW
2,2 kW
1,3 kW
2,1 kW
NO MOTOR
MOTOR TYPE
1
N
PUMP TYPE
North American
REVISION 2 - 05/2007
(NORTH AMERICAN FORMAT)
1
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
MINI 2G POWERPACKS
-6-
14
D
11
G
1
31
5
FLOW LIMITOR ( Port 31 )
F
G
J
L
6,6 l/m
8,0 l/m
4,1 l/m
5,4 l/m
N
Q
R
S
13,2 l/m
15,3 l/m
9,5 l/m
11,2 l/m
Special
Adjustable flow limitor (Port 3 external)
2,2 l/m
3,1 l/m
1,1 l/m
1,4 l/m
*
X
2
4
5
1
3
9
AIR PILOT
SPECIAL
115 VAC
230 VAC
24 VDC
24 VAC
NOT APPLICABLE
12 VDC
(SEPERATE MULTIPLE OPTIONS WITH “ / “ )
VOLTAGE - OPTIONAL VALVES
*
A
B
C
E
W
X Without flow restrictor or flow limitor
* SPECIAL
See page 26 for more
detailed information.
1
2
ADJUSTABLE FLOW CONTROL - PORT 1
VLB IN BLOCK (ANTI DRIFT)
2 SPEED BLOCK, PORTS 1 & 2
VNF IN BLOCK (ANTI DRIFT)
Port 6 Only, with flow limitor on port 31
Port 1 & Port 2, with flow limitor on port 31
Port 6 Only
Port 1 Only, with flow limitor on port 31
Port 1 & Port 2
Port 1 Only
** SPECIAL
VF
VB
SA
AF
10
11
20
21
60
61
25
C2
CC
CO
CY
CT
CP
CF
CB
PG
F3
F2
T 17,6 l/m
U 20,3 l/m
V 22,3 l/m
RELIEF SETTING
(PSI)
1 10 TO 300 BAR (145 TO 4350 psi)
* Special
RELIEF RANGE
P SEALED
N NOT SEALED
RELIEF VALVE
N ####
51
21
2
3
4
5
FILTER, 5MIC, OIL THROUGH PORT 21
PRESSURE GAUGE
FILTER, 5MIC, OIL THROUGH PORT 31
CETOP 3 - DUAL FLOW CONTROL
CETOP 3 - DUAL COUNTERBALANCE VALVE
CETOP 3 - 3 POS, TANDEM CENTRE
CETOP 3 - DUAL PO CHECK
CETOP 3 - 3 POS, OPEN CENTRE
CETOP 3 - 3 POS, Y CENTRE
CETOP 3 - 2 POSITION
CETOP 3 - 3 POS, CLOSED CENTRE
CETOP 3 - BASEPLATE ONLY
PORTING / OPTIONAL VALVES MOUNTED ON PORTS 1 & 2
X
3
MOUNTING POSITION
1
6
4
1
1725 RPM
3450 RPM
1725 RPM
3450 RPM
230 / 460
230 / 460
575
575
0,12 Cubic / inch
0,18 Cubic / Inch
0,24 Cubic / Inch
0,30 Cubic / Inch
0,36 Cubic / Inch
2 cc / rev
3 cc / rev
4 cc / rev
5 cc / rev
6 cc / rev
CX
1
2
3
4
5
6
VNF
12
24VDC
14
24VAC
15
48VAC
17
115VAC
11
230VAC
13
AIR PILOT 19
0.53 Gal
0.66 Gal
0.79 Gal
1.05 Gal
1.32 Gal
1.32 Gal
2,0 L
2,5 L
3,0 L
4,0 L
5,0 L
5,0 L
NO RESERVOIR
1,5 L
0.40 Gal
TANKS
12VDC
X
E
A
H
B
S
C
R
VNO
22
24
25
27
21
23
29
XX
Cartridge valves
12 L
34 L
10 L
15 L
6,3 L
7,5 L
6,0 L
6,0 L
3.17 Gal
8.98 Gal
2.64 Gal
3.96 Gal
1.66 Gal
1.98 Gal
1.58 Gal
1.58 Gal
*
X
3
4
5
6
7
8
9
N
Z
U
G
K
D
L
Ds
Ms
Y
6
X
2
CX
11.6 Gal
18.5 Gal
5.28 Gal
7.92 Gal
1.71 Gal
3.17 Gal
*
Qa
Da
La
Ma
Na
Oa
Ya
VNF = NORMALLY CLOSED. <20L/M
VNF2G = NORMALLY CLOSED. <10L/M (no override!)
VNO = NORMALLY OPEN.
VLB = DOUBLE LOCK.
CT3 - 4/3 WAY, TANDEM CENTRE.
CT2 = 4/2 WAY.
20
3 WAY WITH FREEFLOW
40
PROPORTIONAL VALVE 10L/MIN 90
PROPORTIONAL VALVE 20L/MIN 91
SPECIAL
**
*
X
W
T
E
V
MANUAL LEVER VALVE, 2 WAY
SPECIAL
50 hz
8 VANE AIR MOTOR
WASHDOWN
THERMAL PROTECTION
NONE
MOTOR SPECIAL
2
12 L
3.17 Gal
SPECIAL
44 L
70 L
20 L
30 L
6,5 L
12 L
CT2
72
74
75
77
71
73
4 way
VLB VNF2G CT3
42
32
52
44
34
54
45
35
55
47
37
57
41
31
51
43
33
53
39
2 way
NONE, PORTS BLOCKED
VALVES - MOUNTED ON PORTS 3 & 4
KEYED SHAFT, NO RELAY
SHAFT TYPE / RELAY
0,06 Cubic / Inch
AIR MOTOR
SPECIAL
1725 RPM
3450 RPM
115 / 230
115 / 230
NO MOTOR
1 cc / rev
PUMP CAPACITY
SPECIAL
*
0
A
B
0.33 HP
D
0.50 HP
G
0.75 HP
F
1.00 HP
X
1.50 HP
Y
2.00 HP
W
3.00 HP
4.00 HP(AIR) Z
R
5.00 HP
NO MOTOR
0.25 HP
VOLTAGE
2
GENERATION
MOTOR TYPE
1
N
PUMP TYPE
North American
REVISION 2 - 05/2007
(NORTH AMERICAN FORMAT)
ALTERNATING CURRENT
1
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
MINI 2G POWERPACKS
-7-
11
D
11
G
1
31
5
FLOW LIMITOR ( Port 31 )
F
G
J
L
6,6 l/m
8,0 l/m
4,1 l/m
5,4 l/m
N
Q
R
S
13,2 l/m
15,3 l/m
9,5 l/m
11,2 l/m
Special
Adjustable flow limitor (Port 3 external)
2,2 l/m
3,1 l/m
1,1 l/m
1,4 l/m
*
X
2
4
5
1
3
9
AIR PILOT
SPECIAL
115 VAC
230 VAC
24 VDC
24 VAC
NOT APPLICABLE
12 VDC
(SEPERATE MULTIPLE OPTIONS WITH “ / “ )
VOLTAGE - OPTIONAL VALVES
*
A
B
C
E
W
X Without flow restrictor or flow limitor
* SPECIAL
See page 26 for more
detailed information.
1
2
ADJUSTABLE FLOW CONTROL - PORT 1
VLB IN BLOCK (ANTI DRIFT)
2 SPEED BLOCK, PORTS 1 & 2
VNF IN BLOCK (ANTI DRIFT)
Port 6 Only, with flow limitor on port 31
Port 1 & Port 2, with flow limitor on port 31
Port 6 Only
Port 1 Only, with flow limitor on port 31
Port 1 & Port 2
Port 1 Only
** SPECIAL
VF
VB
SA
AF
10
11
20
21
60
61
25
C2
CC
CO
CY
CT
CP
CF
CB
PG
F3
F2
T 17,6 l/m
U 20,3 l/m
V 22,3 l/m
RELIEF SETTING
(PSI)
1 10 TO 300 BAR (145 TO 4350 psi)
* Special
RELIEF RANGE
P SEALED
N NOT SEALED
RELIEF VALVE
N ####
51
21
2
3
4
5
FILTER, 5 MIC, OIL THROUGH PORT 21
PRESSURE GUAGE
FILTER, 5 MIC, OIL THROUGH PORT 31
CETOP 3 - DUAL FLOW CONTROL
CETOP 3 - DUAL COUNTERBALANCE VALVE
CETOP 3 - 3 POS, TANDEM CENTRE
CETOP 3 - DUAL PO CHECK
CETOP 3 - 3 POS, OPEN CENTRE
CETOP 3 - 3 POS, Y CENTRE
CETOP 3 - 2 POSITION
CETOP 3 - 3 POS, CLOSED CENTRE
CETOP 3 - BASEPLATE ONLY
PORTING / OPTIONAL VALVES MOUNTED ON PORTS 1 & 2
X
3
MOUNTING POSITION
1
6
4
1
MOTOR SPECIFICATIONS - DIRECT CURRENT
SPECIFICATION MOTEUR - COURANT CONTINU
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
152
20’
43
SPECIFICATIONS
20’
DS1
VOLTAGE
TENSION
12VDC
REFERENCE
REFERENCE
114133
NOMINAL POWER
PUISSANCE NOM.
1,3 kW
S3
S3
10%
PROTECTION
PROTECTION
IP44
MASS
MASSE
7,5 Kg
20°
220
5 bar
1003
1004
1005
10
06
10
10
05
100
4
1003
1002
1001
0
50
100
150
200
S3
S2
250
100
100
1
200
10
300
20
04
06
10
05
Flow (l/min) / Debit (l / min)
Amperage / Intensite en Amperes
Continuous Duty / Service Continu
Temporary Duty (min) / Service Temporaire (min)
Intermittent Duty (10% of 10 min) / Service Intermittent (10% de 10 min)
Starting Amperage / Intensite de demarrage:
10
10
10
Q:
I:
S1:
S2:
S3:
ID:
4,3
4
Q
3,7
3,2
2,9
3,4
3,3
3
l 64,1 89,7 116,8 142,9 155,6 168,1 180,4 192,6
S2 40
30,4
15,7
6,3
4,5
7,7
9,5
5,3
S3 39,4 24,8 17,2 13,1 11,6 10,4 9,5
8,7
7,2
8,2
Q
4,8
4,2
6,3
5,5
5,2
4,5
l 68,6 118,3 169,4 218
241,7 265,4 288,9 312,6
15,2
S2 40
2
1,3
3,3
2,6
1,6
6,2
10,3
6,3
5,6
4,4
S3 35,9 16,9
7,3
5
10
Q 12,2
6,8
6,1
8,2
l 73,4 146,8 221,1 292,8 328,7
180 bar max
S2 40
8,9
3,2
1,6
1,2
S3 32,7 12,6
7,2
4,9
4,1
Q 16,1 12,5
9,6
l 76,6 173,6 271,8
130 bar max
S2 40
5,9
1,9
S3 30,8 10
5,4
Q 19,9 14,6 10,5
l 81,4 199,8 320,9
105 bar max
S2 38,7
4,1
1,3
8,2
S3 28,3
4,3
Q 23,5 16,3
l 86,9 227,5
85 bar max
3
S2 32,8
S3 25,9
6,9
10
1006
20
50 bar 100 bar 150 bar 175 bar 200 bar 225 bar 250 bar
2900
2175
725
1450
2540
3260
3630
PSI
PSI
PSI
PSI
PSI
PSI
PSI
Amperage - Intensite (Amps)
1002
13,5
PRESSURE - PRESSION
DUTIES - SERVICES
72
PSI
1001
14,5
Flow - Debit (l/min)
PUMPS
POMPES
136
138
Ø 114
66
20°
CODE
CODE
30
02
03
40
Duties - Services (S2=min , S3=%)
50
Curves drawn using Shell Tellus T46
Viscosity of 46 cST (+/- 10%) at 40’C
Ambient temperature 20’C
Note: Specifications subject to change
MINI POWER - PACKS
MINI CENTRALES
2G
-8-
TYPE
TYPE
DS - 12 VDC:
Bar
MOTOR SPECIFICATIONS - DIRECT CURRENT
SPECIFICATION MOTEUR - COURANT CONTINU
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
152
20’
43
SPECIFICATIONS
20’
DS2
VOLTAGE
TENSION
24VDC
REFERENCE
REFERENCE
114134
NOMINAL POWER
PUISSANCE NOM.
1,5 kW
S3
S3
10%
PROTECTION
PROTECTION
IP44
MASS
MASSE
7,5 Kg
20°
220
PUMPS
POMPES
1003
1004
1005
13,5
250
25
5 bar
50 bar 100 bar 150 bar 175 bar 200 bar 225 bar 250 bar
2900
2175
2540
3260
3630
725
1450
PSI
PSI
PSI
PSI
PSI
PSI
PSI
200
20
Q
4,1
l 36,9
S2 15
S3 28,5
8
Q
l 38,8
S2 14,4
S3 27,4
Q 11,8
l 40,7
S2 13,7
S3 26,2
Q 15,6
l 42
S2 13,3
S3 25,5
Q 19,3
l 44,1
S2 12,7
S3 24,4
Flow - Debit (l/min)
10
150
15
10
05
100
100
10
4
1003
1002
50
5
1001
00
0
50
50
100
100
150
150
S2
200
200
250
250
Bar
300
S3
-50
50
1001
-100
100
-150
150
-200
200
0
Q:
I:
S1:
S2:
S3:
ID:
06
05
10
06
10
Q
l
1006
S2
S3
3,9
3,6
3,2
3
3,4
3,3
3,1
47,7
59,8 71,8 77,7 83,5 89,3 95
11,7
9,1
5,7
4,6
6,4
7,1
5,1
22,7 18
9,9
14,5 13,1 11,9 10,9
7
5,2
4,8
6,3
5,7
5,4
5
60,5 84,1 107
118,2 129,5 140,6 151,7
8,9
2,3
1,4
3,6
2,9
1,8
5,6
17,7
11,8
6
4,5
7,1
8,3
5,2
9,9
7,5
7,1
8,5
73,6 108,4 142,5 159,2
180 bar max
6,9
3,5
1,7
1,1
14,1
8,1
5,1
4,2
12,5
10,4
86,1 132,6
130 bar max
5,4
2,2
11,4
5,8
14,9 12
98,4 155,7
105 bar max
4,3
1,2
9,4
4,3
22,9 16,9
46,4 111,5
85 bar max
12
3,3
23,2
7,8
Amperage - Intensite (Amps)
1002
14,5
PRESSURE - PRESSION
DUTIES - SERVICES
72
PSI
1001
136
138
Ø 112
66
20°
CODE
CODE
10
10
Flow (l/min) / Debit (l / min)
Amperage / Intensite en Amperes
Continuous Duty / Service Continu
Temporary Duty (min) / Service Temporaire (min)
Intermittent Duty (10% of 10 min) / Service Intermittent (10% de 10 min)
Starting Amperage / Intensite de demarrage: 650 Amps
20
20
10
10
04
30
30
100
2
03
40
40
Duties - Services (S2=min , S3=%)
50
50
60
Curves drawn using Shell Tellus T46
Viscosity of 46 cST (+/- 10%) at 40’C
Ambient temperature 20’C
Note: Specifications subject to change
MINI POWER - PACKS
MINI CENTRALES
2G
-9-
TYPE
TYPE
DS - 24 VDC: 1,5kW
MOTOR SPECIFICATIONS - DIRECT CURRENT
SPECIFICATION MOTEUR - COURANT CONTINU
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
194,5
15’
43
CODE
CODE
BK1
VOLTAGE
TENSION
12VDC
REFERENCE
REFERENCE
114806
NOMINAL POWER
PUISSANCE NOM.
2,1 kW
S3
S3
10%
PROTECTION
PROTECTION
IP44
MASS
MASSE
9,9 Kg
20°
14,5
260,5
5 bar
1002
50 bar 100 bar 150 bar 175 bar 200 bar 225 bar 250 bar
725
PSI
1450
PSI
2175
PSI
2540
PSI
2900
PSI
3260
PSI
3630
PSI
3,6
3,3
3,2
3,1
4,6
4,1
2,9
3
55,7 78,4 102,9 126,6 138,2 149,6 160,9 172
30
30
28,8 15,6 11,9 9,2
6
7,4
45
40
26,8 22,4 19
45
16,3 14,2
6,1
5,4
5,1
4,9
4,5
8,8
7,1
4,7
59,7 104,2 150,8 195
216,3 237,3 258,1 278,6
9
4,2
3,3
2,8
2,3
30
27,8
2,5
9
7,7
45
39
18,7 11
6,2
6,8
1005
10
1004
1003
1002
1001
0
50
100
150
200
250
S2
100
Bar
S3
1001
200
10
02
300
Flow (l/min) / Debit (l / min)
Amperage / Intensite en Amperes
Continuous Duty / Service Continu
Temporary Duty (min) / Service Temporaire (min)
Intermittent Duty (10% of 10 min) / Service Intermittent (10% de 10 min)
Starting Amperage / Intensite de demarrage:
10
20
10
04
105 bar max
10
06
Q:
I:
S1:
S2:
S3:
ID:
6
05
24,3 16,1 12,3
76
203,5 331,4
30
3,8
2
45
10,1 5,2
100
10
Q
l
1006
S2
S3
1004
20
10
Q
l
1005
S2
S3
12,9 9,7
8,1
7
6,6
6,2
64
130,1 197,8 261,5 292,6 323,6
220 bar
max
4,1
2,5
2,2
30
14,3
2
45
25,3 10,7
6,7
5,8
5,3
17
12,1 9,8
8,2
66,8 154,6 243 327,3
165 bar max
2,7
30
8,3
2
7,4
45
17,7
5,3
20,8 14,2 11,2
71,1 178,5 285,9
130 bar max
2,3
30
5,4
6
45
13,2
1003
Flow - Debit (l/min)
1001
30
PRESSURE - PRESSION
DUTIES - SERVICES
72
PSI
Q
l
S2
S3
Q
l
S2
S3
Q
l
S2
S3
Q
l
S2
S3
13,5
Amperage - Intensite (Amps)
PUMPS
POMPES
136
140
Ø 115
66
20°
SPECIFICATIONS
15’
30
40
03
50
Duties - Services (S2=min , S3=%)
Curves drawn using Shell Tellus T46
Viscosity of 46 cST (+/- 10%) at 40’C
Ambient temperature 20’C
Note: Specifications subject to change
MINI POWER - PACKS
MINI CENTRALES
2G
- 10 -
TYPE
TYPE
BK - 12 VDC: 2,1 kW
MOTOR SPECIFICATIONS - DIRECT CURRENT
SPECIFICATION MOTEUR - COURANT CONTINU
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
SPECIFICATIONS
45’
172,8
CODE
CODE
BK2
VOLTAGE
TENSION
24VDC
REFERENCE
REFERENCE
113349
NOMINAL POWER
PUISSANCE NOM.
2,2 kW
S3
S3
10%
PROTECTION
PROTECTION
IP44
MASS
MASSE
7,4 Kg
136
114
107,5
66
r81
43
239,8
1002
1003
5 bar
50 bar 100 bar 150 bar 175 bar 200 bar 225 bar 250 bar
1450
PSI
4,7
31
29
44,8
9,1
34
27,7
42,8
4,3
45
23,1
36,1
7,8
60
17,5
28,1
4
3,6
3,5
3,4
3,2
3,3
59
73
79
86
92
98
17,8 13,4 11,6 10
7,4
8,6
28,5 22,5 20,1 18
16,2 14,6
6,8
6
5,8
5,5
5,1
5,3
86
111
123
135 146 158
9,8
5,4
4
3,1
2
2,4
17,8 11,8
9,7
7,9
5,2
6,4
13,5
37
26,5
41
2540
PSI
2900
PSI
725
PSI
3260
PSI
20
3630
PSI
Q
l
1006
S2
S3
25,7 18,1
44
116
23,6
4,8
36,8 10,9
10
05
100
10
4
1002
5
1001
0
50
100
150
200
S2
250
Bar
S3
100
1001
150
200
85 bar max
10
Q:
I:
S1:
S2:
S3:
ID:
06
05
10
06
10
Q
l
1005
S2
S3
10
15
1003
10,8
9,1
8
7,5
75 113
148
166
175 bar max
12,8
5,2
2,3
1,7
21,7 11,5
6,2
4,6
13,5 11,1
89 138
130 bar max
9,3
2,9
17,2
7,5
15,9 12,5
102 168
105 bar max
1,7
6,7
13,7
4,5
17,8
38
25,8
40
21,8
41
24,7
38,5
1004
2175
PSI
72
PSI
Flow - Debit (l/min)
1001
Q
l
S2
S3
Q
l
S2
S3
Q
l
S2
S3
Q
l
S2
S3
25
PRESSURE - PRESSION
DUTIES - SERVICES
Amperage - Intensite (Amps)
PUMPS
POMPES
13,5
14,5
Flow (l/min) / Debit (l / min)
Amperage / Intensite en Amperes
Continuous Duty / Service Continu
Temporary Duty (min) / Service Temporaire (min)
Intermittent Duty (10% of 10 min) / Service Intermittent (10% de 10 min)
Starting Amperage / Intensite de demarrage:
20
10
10
04
30
100
2
03
40
Duties - Services (S2=min , S3=%)
50
Curves drawn using Shell Tellus T46
Viscosity of 46 cST (+/- 10%) at 40’C
Ambient temperature 20’C
Note: Specifications subject to change
MINI POWER - PACKS
MINI CENTRALES
2G
- 11 -
TYPE
TYPE
BK - 24 VDC: 2,2 kW
MOTOR SPECIFICATIONS - DIRECT CURRENT
SPECIFICATION MOTEUR - COURANT CONTINU
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
SPECIFICATIONS
45’
182,8
CODE
CODE
BS2
VOLTAGE
TENSION
24VDC
REFERENCE
REFERENCE
113305
NOMINAL POWER
PUISSANCE NOM.
2,2 kW
S3
S3
10%
PROTECTION
PROTECTION
IP44
MASS
MASSE
8,4 Kg
136
114
107,5
66
r81
43
249,8
1002
5 bar
50 bar 100 bar 150 bar 175 bar 200 bar 225 bar 250 bar
1450
PSI
2175
PSI
2540
PSI
2900
PSI
72
PSI
725
PSI
3260
PSI
3630
PSI
8
65
11,7
33,2
15,2
68
11,4
31,5
6,7
5,7
5
4,8
4,5
4,2
4,4
80
96
111
119
126 133 140
8,5
10
7,2
6,6
6,1
5,2
5,6
24,8 19,1 15,3 13,8 12,6 11,6 10,6
11,1
9
7,8
7,4
7
6,3
6,6
155
169
182 196
210
97 127
6,1
4,3
3,6
3
2
8,4
2,4
7,9
7
18,8 12,5
9,1
5,6
6,2
Q:
I:
S1:
S2:
S3:
ID:
10
05
100
4
1003
10
1002
1001
0
50
100
150
200
250
Bar
S3
S2
100
1001
100
2
200
05
39,7 23,3
79
161
10,1
4
25,3
8,5
1004
06
10
Q
l
1006
S2
S3
1003
10
20
06
10
Q
l
1005
S2
S3
21,9 14,7 11,8 10
9,4
8,8
71
198
219
239
114 157
200 bar
4,2
2,3
1,7
1,2
11
7
max
29,6 14,8
8,9
6,1
5,2
4,5
28,4 17,9 14
73 129
186
145 bar max
10,8
5,9
2,8
28,4 12,1
6,7
34,4 20,7 15,9
76 145 215
115 bar max
10,4
4,9
1,8
26,9 10,1
5,4
30
Flow - Debit (l/min)
1001
Q
l
S2
S3
Q
l
S2
S3
Q
l
S2
S3
Q
l
S2
S3
40
PRESSURE - PRESSION
DUTIES - SERVICES
Amperage - Intensite (Amps)
PUMPS
POMPES
13,5
14,5
10
04
10
03
95 bar max
300
10
20
30
40
50
Duties - Services (S2=min , S3=%)
Flow (l/min) / Debit (l / min)
Amperage / Intensite en Amperes
Continuous Duty / Service Continu
Temporary Duty (min) / Service Temporaire (min)
Intermittent Duty (10% of 10 min) / Service Intermittent (10% de 10 min)
Starting Amperage / Intensite de demarrage:
Curves drawn using Shell Tellus T46
Viscosity of 46 cST (+/- 10%) at 40’C
Ambient temperature 20’C
Note: Specifications subject to change
MINI POWER - PACKS
MINI CENTRALES
2G
- 12 -
TYPE
TYPE
BS - 24 VDC: 2,2kW
MOTOR SPECIFICATIONS - DIRECT CURRENT
SPECIFICATION MOTEUR - COURANT CONTINU
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
SPECIFICATIONS
153,5
22,5
CODE
CODE
CI2
VOLTAGE
TENSION
24VDC
REFERENCE
REFERENCE
111895
NOMINAL POWER
PUISSANCE NOM.
3 kW
S3
S3
15%
PROTECTION
PROTECTION
IP44
MASS
MASSE
13 Kg
125
136
66
r89
129
22,5
43
14,5
13,5
266
72
PSI
1001
1002
Q
l
S2
S3
Q
l
S2
S3
Q
l
S2
S3
Q
l
S2
S3
4,6
32,5
30
41,6
8,8
34,8
29,7
39,8
50 bar 100 bar 150 bar 175 bar 200 bar 225 bar 250 bar
2900
2175
725
1450
2540
3260
3630
PSI
PSI
PSI
PSI
PSI
PSI
PSI
4,2
3,9
3,7
3,6
3,5
3,3
3,4
45,9 60,6 75
82
88,9 95,7 102,4
25,7 21,6 18
16,3 14,8 13,4 12,2
34,5 29,6 25,1 23
21,1 19,4 17,8
5,6
7,7
6,9
6,4
6,1
5,9
5,7
61,4 89,6 116,2 129
141,5 153,8 166
21,4 14,7
10
8,3
7
5,2
6
29,3 20,9 15,1 13,1 11,6 10,3 9,4
Q
l
1006
S2
S3
25,1 19,1 15,7 12,5
44,5 121,5 197,6 268,3
2,2
26,2
9,3
3,8
3,6
35,1 14,2 7,6
1003
1004
Q:
I:
S1:
S2:
S3:
ID:
20
100
6
1005
10
1004
1003
1002
1001
0
50
100
150
200
250
Bar
S3
S2
1001
100
100
2
200
100
06
10
Q
l
1005
S2
S3
13
10,9
9,6
8,7
8,3
7,9
7,4
7
37,4 77,1 118
155,9 174,4 192,8 211,3 229,6
28,6 17,5
3,4
3
9,7
5,9
4,7
4
6,9
6
38,2 24,4 14,8 10,2 8,8
7,8
17,2 13,8 12
10,5 9,7
8,9
8,3
225
92 145
244,3 266,2
39
195,1 220
bar
27,9 14,2
6,7
3,9
3,2
2,7
2,3 max
37,4 20,3 11,2 7,7
6,5
5,2
3,7
21,3 16,6 14
11,6 10,5
41,6 106,5 170,5 232,5 261,1
180 bar max
27,1 11,5
4,9
2,9
2,4
36,2 17
9,1
5,8
4,1
Flow - Debit (l/min)
5 bar
Amperage - Intensite (Amps)
PUMPS
POMPES
30
PRESSURE - PRESSION
DUTIES - SERVICES
150 bar max
300
10
20
30
10
05
40
10
3
04
50
Duties - Services (S2=min , S3=%)
Flow (l/min) / Debit (l / min)
Amperage / Intensite en Amperes
Continuous Duty / Service Continu
Temporary Duty (min) / Service Temporaire (min)
Intermittent Duty (10% of 10 min) / Service Intermittent (10% de 10 min)
Starting Amperage / Intensite de demarrage: 900 Amps
Curves drawn using Shell Tellus T46
Viscosity of 46 cST (+/- 10%) at 40’C
Ambient temperature 20’C
Note: Specifications subject to change
MINI POWER - PACKS
MINI CENTRALES
2G
- 13 -
TYPE
TYPE
CI - 24 VDC: 3 kW
MOTOR SPECIFICATIONS - AC CURRENT
SPECIFICATION MOTEUR - COURANT CA
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
AB
No Capacitor on
3 phase motors
Capacity
P3
MODEL cm3/rev
Bar
Capacité
P3
43
MODELE
Y
66
1001
1002
1003
1004
1005
1006
88,9
136
O
13,5
14,5
62,0
L
HP
0.25
0.33
0.50
0.75
1.00
1.50
2.00
3.00
RPM
t/min
1725
3450
1725
3600
1725
3450
1725
3600
1725
3450
1725
3450
1725
3450
1725
3450
SPECIFICATIONS - SPECIFICATION
L
O
0.25
0.33
0.50
0.75
1.00
1.50
2.00
3.00
5.00
RPM
t/min
1725
3450
1725
3600
1725
3600
1725
3600
1725
3450
1725
3600
1725
3450
1800
3450
1725
3450
Y
AB
Amps Weight
Intensite Masse
Reference
Reference
9,6 101053C/L
194 167
111 117
2,1
227
207
227
223
235
261
181
162
181
180
180
125
113
125
141
141
123
135
na
135
136
135
142
248
248
273
261
180
180
180
180
141
141
119
134
136
136
135
135
9,6 M002256C/L 6
2,9
9,1 G534
2,2
3,9 10,9 M009086C/L 6
10 110399C/L
3,6
5,4 11,8 110087C/L 6,7
5,3 12,7 D312
6
7,0 15,9 114466
6,0 13,6 114475C/L 6
8,6 18,6 110089C/L 6,7
8,5 15,5 110909
9,2 19,5 110090C/L6,7,8
10 20,9 113931
297 180
286 180
126 135
134 135
297 182
128 136
MOTOR
MOTEUR
HP
57
115 / 230V, SINGLE PHASE
21 120341MOD 8
14
O
Y
AB
Amps Weight
Intensite Masse
194 167
0 117
0,5
194
na
201
248
223
248
167
175
169
187
183
187
0
0
0
0
0
0
117
131
117
142
135
142
0,6
0,8
na
0,9
1,1
1,3
248
223
248
248
180
180
180
187
0
0
0
0
136 1,4
136 1,3
135 2,0
142 1,85
261
261
324
273
0
0
180
180
187
180
0
0
0
0
0
0
0
0
136
135
142
136
0
0
MINI POWER - PACKS
MINI CENTRALES
Reference
Reference
6,8 101050C/L
8,7
9,5
na
na
10
na
14,1
10,9
13,6
na
16,8
15,5
20
101052C/L
K702
101907C/L
K704
110178C/L
K706
1
114467
1
114468
110893C/L
K721
114327C/L
2,5
111611C/L
2,2
G591
3,4
3,2 19,6 115597
0 160280MOD 5
0
0 117026
0
2G
RPM
t/min
HP
0.25
0.33
0.50
0.75
1.00
1.50
2.00
3.00
5.00
575V, THREE PHASE
SPECIFICATIONS - SPECIFICATION
L
MOTOR
MOTEUR
1725
3450
1725
3600
1725
3450
1725
3600
1725
3450
1725
3450
1725
3450
1725
3450
3450 RPM
l /min
Debit Nominale
cm3/t
Bar
1,02
2,05
3,07
4,09
5,12
6,14
300 1,7
300 3,4
300 5,1
250 6,8
200 8,6
150 10,4
1725 t/min
l /min
3450 t/min
l /min
3,4
6,9
10,4
13,9
17,5
21,0
Note! Above flow ratings are calculated using the
maximum continuous pressure and volumetric efficiency
at the specified RPM. Consult performance graphs for
further info.
62,0
38,1 38,1
MOTOR
MOTEUR
Nominal Flow
1725 RPM
l /min
230 / 460V, THREE PHASE
SPECIFICATIONS - SPECIFICATION
L
O
Y
Amps Weight
Intensite Masse
AB
194 167
0 117
194
213
201
212
223
248
168
172
169
172
183
0
0
0
0
0
0
235
223
248
248
183
183
180
180
0
0
0
0
272 180
261 180
0
0
273 180
0 135
1725
0
0
3450 299 182
0
0
0 135
0,7
Reference
Reference
8,7 101078C/L
8,2
117 0,8
9,5
na 0,9
117 1,0 10,9
na 0,75 11,4
135 1,4
10
142 1,6 10,5
135 1,9 11,4
133 1,6 10,9
135 2,5 13,6
133 2,1 13,2
135 3,1 15,7
133 2,8 15,5
101079C/L
D390
100913C/L
110143C/L
110034C/L
D392
110035CL
110181
110444C/L
110917
113026C/L
113927
17,1 114615
0 0
0
6,5 20,7 116417
4,0
Specifications subject to change, we reserve the right to substitute motors, please
advise sales dept of any specific requirements.
Amp ratings are at the “high” voltage.
Footnotes
1. Dual rated 50/60hz (2850/3450 RPM) (1425/1725 RPM)
5. 182 Frame Modified to 56C face
6. Manual thermal protection
7. Red industrial motor
8. 230V only
HP Required for
continuous duty.
Common Conversion
Factors
LPM = cm3/rev x RPM x Eff(v)
1000
HP = LPM x Bar
402
GPM = cm3/rev x RPM x Eff(v)
3785
HP = GPM x PSI
1542
GPM = LPM / 3.785
psi = Bar x 14.5
lbs = Kg x 2.2
In3 = cm3 / 16.39
HP = kW / 0.745
CFM = (l/s) / 0.467
Pump Flow Output
Note! efficiency is already taken
into account in above formulas.
Eff(v) may be estimated at between 0.93 and 0.98
- 14 -
TYPE
TYPE
Efficiency increases with pump size and RPM.
AC- NEMA FRAME
MOTOR SPECIFICATIONS - AIR MOTORS
SPECIFICATION MOTEUR - AIR MOTEUR
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
Capacity
MODEL cm3/rev
Air Muffler not shown!
MODELE
66
136
165,1
13,5
14,5
See Below
P3
cm3/t
Bar
1,02
2,05
3,07
4,09
5,12
6,14
300 2,3
300 4,7
300 7,0
250 9,5
200 12,1
150 14,6
4AM-NRV-50C -4VANE
4AM-NRV-70C -8VANE
MAXIMUM HP
PUISSANCE MAXI
1.7 HP
MAX SPEED
VITESSE MAXI
3000 RPM
MAX PRESSURE
PRESSION MAXI
6.9 BAR
FRAME SIZE
TAILLE
56C
MASS
MASSE
5,4 Kg
FREE AIR CONSUMPTION ( l/s )
CONSUMTION DE *******
40
REFERENCE
REFERENCE
6AM-NRV-11A -4 VANE
6AM-NRV-22A -8 VANE
MAXIMUM HP
PUISSANCE MAXI
4.0 HP
MAX SPEED
VITESSE MAXI
3000 RPM
MAX PRESSURE
PRESSION MAXI
6.9 BAR
FRAME SIZE
TAILLE
56C
MASS
MASSE
10,8 Kg
FREE AIR CONSUMPTION ( l/s )
CONSUMTION DE *******
REFERENCE
REFERENCE
MAXIMUM HP
PUISSANCE MAXI
5.0 HP
MAX SPEED
VITESSE MAXI
2500 RPM
MAX PRESSURE
PRESSION MAXI
6.9 BAR
FRAME SIZE
TAILLE
145C
MASS
MASSE
12,6 Kg
MINI POWER - PACKS
MINI CENTRALES
FREE AIR CONSUMPTION ( l/s )
CONSUMTION DE *******
8AM-NRV-28A -4 VANE
8AM-NRV-32A -8 VANE
52,3
65,3
5,6 bar
25
20
4,2 bar
15
10
5
2,8 bar
1,4 bar
165,1
0
500
1000 1500
2000 2500
3000 SPEED - VITESSE (RPM - t/min)
60
7,0 bar
69,9
1/2” NPT
79,5
78,8
50
5,6 bar
40
30
20
10
4,2 bar
2,8 bar
1,4 bar
0
500
1000 1500
2000 2500
3000 SPEED - VITESSE (RPM - t/min)
165,1
7,0 bar
70
69,9
1/2” NPT
35,1
60
5,6 bar
50
4,2 bar
40
30
20
2,8 bar
1,4 bar
10
0
2G
2,9
5,8
8,8
11,7
14,8
17,8
31,8
7,0 bar
80
REFERENCE
REFERENCE
3000 t/min
l /min
30
0
SPECIFICATIONS
Debit Nominale
2500 t/min
l /min
1/4” NPT
35
0
SPECIFICATIONS
3000 RPM
l /min
Note! Above flow ratings are calculated using the
maximum continuous pressure and volumetric efficiency
at the specified RPM. Consult performance graphs for
further info.
57
SPECIFICATIONS
Bar
Nominal Flow
2500 RPM
l /min
Capacité
43
1001
1002
1003
1004
1005
1006
P3
0
500
1000
1500
2000
2500 SPEED - VITESSE (RPM - t/min)
- 15 -
165,1
TYPE
TYPE
AIR MOTORS
MOTEUR L’ A
97,5
89,7
RESERVOIRS - PLASTIC
RESERVOIRS - PLASTIQUE
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
The information contained on this page is specific to
hydraulic units assembled in North America. Volumes
may differ for units assembled in France.
31
RESERVOIRS
RÉSERVOIRS
CODE
CODE
138
124
89
115
30
T E
31
A H
B S
Z
T
E
A
H
B
S
Z
TYPE
TYPE
1,1
1,5
2,0
2,5
3,0
4,0
6,0
L
L
L
L
L
L
L
USEABLE CAPACITY
CAPACITÉS UTILES
HORIZONTAL
Horis
1,06
1,21
1,60
1,89
2,62
5,57
L
L
L
L
L
L
VERTICAL
Veric
0,58
0,97
1,56
2,05
3,23
5,08
Dimensions
Dimensions
105
142
187,5
238
278,5
384
600
L
L
L
L
L
L
1 34
RESERVOIRS
RÉSERVOIRS
181
107,5
56
181
C
U
USEABLE CAPACITY
CAPACITÉS UTILES
CODE
CODE
TYPE
TYPE
HORIZONTAL
Horis
VERTICAL
Veric
Dimensions
Dimensions
C
U
5,0 L
6,0 L
3,75 L
4,64 L
3,22 L
4,61 L
220
275
Note! 56C face motor base must be raised 2 mm from
mounting suface when used with C and U reservoirs.
31
128
1 54
56
222
RESERVOIRS
RÉSERVOIRS
USEABLE CAPACITY
CAPACITÉS UTILES
CODE
CODE
TYPE
TYPE
HORIZONTAL
Horis
VERTICAL
Veric
R
K
D
5,0 L
7,5 L
10,0 L
3,87 L
5,95 L
7,24 L
2,34 L
4,92 L
6,41 L
Dimensions
Dimensions
120
205
249
Note! 56C face motor base must be raised 23mm from
mounting suface when used with R, K and D reservoirs.
R
222
K
D
85,5
89
20
55
300
80
61
140
151
RESERVOIRS
RÉSERVOIRS
CODE
CODE
TYPE
TYPE
G
6,3 L
USEABLE CAPACITY
CAPACITÉS UTILES
HORIZONTAL
Horis
5,4 L
VERTICAL
Veric
Dimensions
Dimensions
na
208
Usable Reservoir Capacity is the amount of oil that can be withdrawn
from the tank using the standard suction strainer setup.
In vertical applications, the fill line is to the bottom of the filler elbow.
Vertical capacity may be increased by sealing the filler elbow threads and
repositioning the intake strainer.
MINI POWER - PACKS
MINI CENTRALES
2G
- 16 -
RESERVOIRS - MISC
RESERVOIRS - MISC
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
110
80
42
110
RESERVOIRS
RÉSERVOIRS
250
CODE
CODE
Y
Ya
Ds
Ms
Plastic
200
USEABLE CAPACITY
CAPACITÉS UTILES
TYPE
TYPE
14,0
12,0
12,0
33,0
HORIZONTAL
Horis
L
L
L
L
VERTICAL
Veric
Weight
Masse
12,7
10,0
10,7
30,4
2,5 Kg
2 Kg
9 Kg
16 Kg
L
L
L
L
340
221
455
Ya
Bl
a
Co c k P
ate o w
d S de
tee r
l
381
Bl
a
Co c k P
ate o w
d S de
tee r
l
Aluminium
Ds
Ms
33
6
5
21
7
30
193
RESERVOIRS
RÉSERVOIRS
Cast Aluminium
CODE
CODE
Qa
Da
La
Ma
Na
Oa
Qa
Da
La
Ma
Na
Oa
S
MINI POWER - PACKS
MINI CENTRALES
2G
- 17 -
TYPE
TYPE
USEABLE CAPACITY
CAPACITÉS UTILES
HORIZONTAL
Horis
6,5 L
12,0 L
18,0 L
30,0 L
44,0 L
70,0 L
CODE
CODE
B
D
F
G
Qa
Da
La
Ma
Na
Oa
225
270
315
410
425
510
10
5
5
10
10
10
M6
M8
M8
M10
M10
M10
3/8
3/8
1/2
1/2
1/2
1/2
DIMENSIONS
N
M
260
310
366
490
515
605
187
227
257
292
323
373
VERTICAL
Veric
Weight
Masse
6,0
10,0
15,0
27,0
40,0
63,0
3 Kg
4 Kg
6 Kg
8 Kg
13 Kg
17 Kg
L
L
L
L
L
L
P
R
S
W
220
240
288
340
415
465
160
155
192
176
241
282,5
200
225
270
326
341
422,5
185
200
235
260
325
370
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
POSITION
1
MOUNTING POSITIONS - ALTERNATING CURRENT
POSITION DE MONTAGE - COURANT ALTERNATIF
POSITION
A.C Motor
Moteur C.A
1
2
1
Return
Retour
2
Fixing - Fixation
Hydroperfect Intl. Inc.
5
6
2
6
Inlet
Aspiration
Fixing - Fixation
1
2
3
6
Return
Retour
1
2
Inlet
Aspiration
POSITION
5
A.C Motor
Moteur C.A
6
Fixing - Fixation
POSITION
1
2
5
5
Return
Retour
Inlet
Aspiration
4
LEGEND
A.C Motor
Moteur C.A
Fixing - Fixation
1 Pressure Port / Orifice Pression
2 Return Port / Orifice Retour
6
5
5 Relief Valve / Limiteur de Pression
5
2
POSITION
Return
Retour
2 1
1
Inlet
Aspiration
5
5
Fixing - Fixation
5
2
1
2
1
6
MINI POWER - PACKS
MINI CENTRALES
Inlet
Aspiration
A.C Motor
Moteur C.A
2G
Return
Retour
6
- 18 -
6 Auxillary Pressure Port
Note! Motor configuration may vary
based upon model. Capacitor and
junction box locations may differ.
Please consult with the sales department for clarification.
MOUNTING POSITIONS - DIRECT CURRENT
POSITION DE MONTAGE - COURANT CONTINU
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
POSITION
1
Relay
Relais
Return
Retour
POSITION 2
45°
Terminals
Bornes
2
1
Relay
Relais
5
6
Fixing - Fixation
Inlet
Aspiration
6
1
2
Relay
Relais
6
Return
Retour
5
Inlet
Aspiration
1
2
Inlet
Aspiration
Terminals
Bornes
Fixing - Fixation
45°
3
Fixing - Fixation
POSITION
Return
Retour
2
1
45°
5
Terminals
Bornes
POSITION
5
6
4
LEGEND
Fixing - Fixation
1 Pressure Port / Orifice Pression
6
2 Return Port / Orifice Retour
5
5
Return
Retour
Relay
Relais
Inlet
Aspiration
1
5 Relief Valve / Limiteur de Pression
6 Auxillary Pressure Port
2
45°
Terminals
Bornes
5
5
2
1
Relay
Relais
5
Inlet
Aspiration
Fixing - Fixation
POSITION
2
1
45°
Return
Retour
6
MINI POWER - PACKS
MINI CENTRALES
6
2G
Terminals
Bornes
- 19 -
VALVE MOUNTING ACCESSORIES
ACCESSOIRES POUR MONTAGE
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
P 1
T
25
1
2
2
M 14 x 150 (x2)
34
12
13,5
STANDARD
MOUNTING
CONFIGURATION
23,5
20
3
40,5
4
27,5
136
M
70
MONTAGE
STANDARD
5
50
50
72,5
18
65,5
32,5
OPTIONAL ACCESSORIES
5
Port 1 & 2 Adaptors
#6 JIC Male (Included as Standard)
1/4” NPT Female
#6 SAE Female
30
M 10 x 150 (x2)
VNF 2G
VNF 1G
P 1
1
Mounting block for
electro poppet valves.
( 1G and 2G )
147
300 µ
53
123
135
Montage avec bloc
support electro-valve à
clapet
(1G et 2G )
2
Reference:
10 l/min: K5091997
20 l/min: K5091998
M
30
20
38,6
70,5
VNF 1G
VNF 2G
P 1
1
Mounting block for
electro poppet valves.
With auxillary pressure
port #6
( 1G and 2G )
147
6
135
6
M
29
38,6
45
70,5
MINI POWER - PACKS
MINI CENTRALES
2G
300 µ
M 14 x 150
20
Reference:
10 l/min: K5090149
20 l/min: K5090148
123
Montage avec bloc
support electro-valve à
clapet
(1G et 2G )
- 20 -
2
VALVE MOUNTING ACCESSORIES
ACCESSOIRES POUR MONTAGE
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
P 1
3-way valve with free flow
assembly.
(Dock-leveler)
2
1
2
6
M 14 x 150
6
M
11
31,5
69
58
Reference: K5089114
5
Clapet 3 voies à passage
libre
(free flow)
1
40
P 1
M 14 x 150
( x2 )
Mounting block for
directional valve.
4 Way, 2 Position
B
70
Montage avec Valve
4 Voies, 2 Positions
A
A
M
17,5 43,8
Reference: K5090020
28,5
134
B
40
P 1
1
Montage avec Valve
4 Voies, 3 Positions
70
Reference: K5090020
28,5 15,2
173
85,5
Mounting block for
directional valve.
4 Way, 3 Position
17,5
M
25
MINI POWER - PACKS
MINI CENTRALES
2G
- 21 -
2
VALVE MOUNTING ACCESSORIES
ACCESSOIRES POUR MONTAGE
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
1
58,5
M
20
35
With Pressure outlet
Avec sortie pression
Adjustable flow limitor
assembly.
Limiteur de débit
réglable
12345
12
12345
12
1
12
1
12345
12345
12
1
VNF
1
12345
12345
123456
1234
2G
123456
123456
1
123456
1
123456
1
123456
123456
P 1
12345
123456
12345
123456
12
12
123456
123456
12345
VNF
12345
1234
1G
12345
1234
123456
123456
123456
1
123456
1
123456
1
123456
123456
M
MINI POWER - PACKS
MINI CENTRALES
2G
99
65
6
8
With
Pressure outlet
Avec
sortie pression
40
2
300 µ
M
21
VNF 1G
Flow
Limitor
Limiteur de
débit
0 to - à - 10
l / min
or - ou
VNF 2G
4
1
3
M
53
Reference:
1
1234567
1234567
1234567
1234567
1234567
1234567
1234567
1234567
1234567
1234567
1234567
Flow
restrictor
Freineur
4
1
16
20
Montage avec bloc pour
fonction bi - vitesse
( 1G et 2G )
2
300 µ
1234
1234
12
12
1234
12
12
12
1234
12
1234
VNF
1234
1G
1234
1234
1234
1234
1234
1234
1234
1234
Mounting block for two
speed function.
( 1G and 2G )
1
Without
Pressure outlet
Sans
sortie pression
Without Pressure outlet
Sans sortie pression
1
12345
123
12
1
12345
12345
12
1
1
12345
VNF
12345
1234
2G
1234
1234
1234
1234
1234
1234
123
1234
123
1234
1234567
12345
1234
12345
12
1
12
1234567
12345
1234
12345
12
1
12
1234567
12345
12
1
12
1234567
12345
12
11234567
12
12345
12
11234567
12
1234567
1234567
1234567
123456
12345
123456
123456
123456
123456
123456
VNF 1G 123456
123456
123456
123456
123
123456
1
123
123456
1
123
12
123456
1
12
123456
1
123456
1
123456
123456
12345
123456
12345
123456
123456
123456
123456
VNF 2G 123456
123456
123456
123456
2
300 µ
20
Limiteur de débit externe
(Non Réglable)
P 1
84
External flow limitor
assembly.
(non adjustable)
12345
12
1234567
12345
12
1234567
1234567
12
12
1234567
12
123
12
1234567
12
123
1234567
1234567
1234567
12345
12345
12345
12345
12345
12345
VNF 1G 12345
12345
12345
12345
123
123456
1
123
123456
1
123
12
1
123456
123
12
123456
1
1
123456
123456
12345
123456
12345
12345
12345
12345
VNF 2G 12345
12345
12345
12345
40
- 22 -
M
3
VALVE MOUNTING ACCESSORIES
ACCESSOIRES POUR MONTAGE
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
External check valve
assembly.
(for use with 1G only)
Clapet anti-retour.
12345
12345
12
12
12345
12
12
12
12345
12
12345
VNF
12345
12
11
1G
12345
1234
12
12345
1234
1234
12
123456
123456
12345
1234
123456
123456
12
12
123456
123456
12
123456
123456
123456
123456
12
123456
123456
123456
123456
123456
123456
P 1
with or without flow limitor
avec ou sans limiteur de débit
with adjustable
flow limitor
avec limiteur de
débit réglable
1
2
6
300 µ
123456
12
123456
1
12
123
12
123456
1
123
12
123456
1
123456
1
VNF
123456
2G
1234567
1234
123456
1234567
12
1234567
12
1234567
12
1234567
12
1234567
1234567
1234567
MINI POWER - PACKS
MINI CENTRALES
2G
20
16,5
35
P 1
adjustable
limitor
limiteur de
réglable
with or without flow limitor
avec ou sans limiteur de débit
1
2
6
75
with
flow
avec
débit
98
Clapet anti-retour
123
123456
1
123
123456
1
12
12
123456
1
1
1
1
123456
1
12
1
VNF
123456
1
12
1234
2G
12345
123456
1234
12345
1234
1234567
123456
1234567
123456
12
12
1234567
123456
1234567
123456
12
12
1234567
123456
1234567
123456
1234567
123456
123456
123456
M
20
Check valve assembly
(for use with 2G only)
85
60
12345
12
12345
12
12345
12
12
12345
12
12345
12
12345
VNF
12345
1G
12345
1234
123456
12345
123456
123456
12
12
123456
12
123456
123456
123456
300 µ
13,5
25
- 23 -
M
VALVE MOUNTING ACCESSORIES
ACCESSOIRES POUR MONTAGE
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
OPTION : with flow restrictor
on Port 4
OPTION : avec freineur sur Orifice 4
90
48,5
Mounting block for
Proportional valve
( 10 or 27 l / min )
47,9
P 1
OPTION : with flow restrictor
on Port 4
OPTION : avec freineur sur Orifice 4
2
1
MONTAGE avec
valve proportionnelle
( 10 ou 27 l / min )
178
300 µ
20
17,5
53
M
Shown with optional
emergency decent
valve.
50
6,5
20
40
Avec Commande de
secours
96
P 1
1
Commande manuelle de
décompression
2
179
Manual decompression
valve assembly.
Reference: K5091749
140
300 µ
20
53
93
M
50
111,2
MINI POWER - PACKS
MINI CENTRALES
2G
- 24 -
VALVE MOUNTING ACCESSORIES
ACCESSOIRES POUR MONTAGE
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
B
31,8
32,5
78,5
A
Mounting Block for
2 X single acting setup.
A
1
300 µ
2
147
B
135
M
30
70.5
A
32,5
Mounting block for
2 x single acting setup
with build in circuit relief.
46
97
B
C
P 1
A
1
2 T
147
135
M
70,5
MINI POWER - PACKS
MINI CENTRALES
2G
- 25 -
2
B
5
30
300 µ
C
VALVE MOUNTING ACCESSORIES
ACCESSOIRES POUR MONTAGE
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
P
T
1
2
A1
5
Mounting block for
CETOP 3 valve.
12
( 1 Station )
(Alternate Method)
A
70
Montage avec
3
1
8
bloc CETOP
( 1 fonction )
B
B1
2
(x2) M14 x 150
Block - Bloc
1 Function - Fonction
26
50
M
=
=
1
30
72,5
P
T
1
2
5
CETOP 3
70
Mounting block for
Spacer
12
A
valves.
B3
A2
B2
A1
B1
8
( 2 and 3 Station )
(Alternate Method)
12345678901234567
12345678901234567
12345678901234567
12345678901234567
12345678901234567
A3 12345678901234567
12345678901234567
12345678901234567
12345678901234567
12345678901234567
Montage avec
3
50
150
(x6) M14 x 150
Block - Bloc
3 Functions - Fonctions
100
150
50
100
1
MINI POWER - PACKS
MINI CENTRALES
2G
25
40
21
1
(x4) M14 x 150
Block - Bloc
2 Functions - Fonctions
26
Note! This spacer is not
used with Direct Current
Motors.
B
123456789
123456789
123456789
123456789
123456789
123456789
123456789
123456789
123456789
123456789
Spacer
bloc CETOP
2 et 3 fonctions
72,5
- 26 -
2
M
VALVE MOUNTING ACCESSORIES
ACCESSOIRES POUR MONTAGE
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
1 to 6 Stations are available.
Please add base dimension of 50mm
for each station.
8
Ports
Orifices
( SAE #6 )
Mounting block for
CETOP 3
B2
A1
B1
50
A2
A2
B2
50
25
valves
( 1 or more Stations )
(Preferred Method)
A1
B1
Montage avec
25
3
18
bloc CETOP
2 fonctions
4
Note! This spacer is not
used with Direct Current
Motors.
66
5
3
4
M
3
Mounting with
CETOP 3
block
and single acting
function.
51
C
Note! This spacer is not
used with Direct Current
Motors.
C
A
Attention:
B
A
Montage avec
bloc CETOP
1 fonctions
3
B
135
147
5
M
30
70,5
MINI POWER - PACKS
MINI CENTRALES
2G
- 27 -
VALVES AND SPECIFICATIONS
VALVES ET SPECIFICATIONS
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
A
A
A
V.N.F
V.N.O
V.N.F
B
B
B
Normally open valve
Valve Normalement Ouverte
1G - 20L/MIN
B
B
Normally Closed Valve
Valve Normalement Fermée
2G - 10L/MIN
A
Normally Closed Valve
Valve Normalement Fermée
1G - 20L/MIN
V.L.B
S
B
Double Lock Valve
Valve Logique Bi-directionnelle
1G - 20L/MIN
Emergency Override
(Unscrew for opening of circuit)
72
22,6
S
50,5
63
88,6
16,5
DIN 43 650
DIN 43 650
DIN 43 650
3 / 4" 16 UNF - 2B SAE
3 / 4" 16 UNF - 2B SAE
3 / 4" 16 UNF - 2B SAE
A
A
A
B
B
P
PSI
174
145
116
87
58
29
Pressure Loss
Perte de charge
PSI bar
P
Pressure Loss
Perte de charge
bar
12
10
8
6
4
2
0
2
4
6
8
Specifications / Specifications
Voltage
Tension
12 VDC
24 VDC
24 VRAC
110 VRAC
220 VRAC
Power
1,5 A
0,7 A
0,7 A
0,2 A
0,1 A
Pressure Loss
Perte de charge
10 l/min
6
87
2
29
B - A
14
145
10
87
6
29
2
A - B
6
9
Voltage
Tension
12 VDC
24 VDC
24 VRAC
110 VRAC
220 VRAC
2G
A
B
( VNO )
( VNF )
12
15
( VNF )
18
Specifications / Specifications
P3 (Bar)
P3 (Bar)
300
300
300
300
300
MINI POWER - PACKS
MINI CENTRALES
203
14 203
10 145
0
P
PSI bar
260 18
Power
1,3 A
0,7 A
1,0 A
0,2 A
0,1 A
- 28 -
P3 (Bar)
P3 (Bar)
300
300
300
300
300
20 l / min
6
9
12
15
Specifications / Specifications
Voltage
Tension
12 VDC
24 VDC
24 VRAC
110 VRAC
220 VRAC
Power
1,3 A
0,7 A
1,0 A
0,2 A
0,1 A
P3 (Bar)
P3 (Bar)
300
300
300
300
300
18
20 l / min
VALVES AND SPECIFICATIONS
VALVES ET SPECIFICATIONS
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
PROPORTIONAL VALVE
VALVE PROPORTIONNELLE
HYDRAULIC CHARACTERISTICS
CARACTERISTIQUES HYDRAULIQUES
( SHELL Tellus Oil T46 at 40°C - 46 Cst )
( Huile SHELL Tellus T46 à 40°C - 46 Cst )
Oil temperature :
Optimal viscosity range :
Max. Leakage :
Repeatibility :
Response time :
Température de l'huile:
de - 15°C à + 80°C
Plage de viscosité optimale: de 12 Cst à 100 Cst
Fuite Maxi:
10 cc en 5 min
Répétabilité:
50 to 100 % du débit Maxi +/- 1%
Temps de réponse:
environ 100ms
from - 15°C to + 80°C
from 12 Cst to 100 Cst
10 cc in 5 min
50 to100 % of Max. flow +/- 1%
approximately 100ms
Nominal voltage :
24 V
Mini - Max. battery voltage : 16,8 V - 28,8 V
S2 Duty :
5 min
S3 Duty :
20% of 10 minute
Current consumption:
300 mA Max
Protection index :
IP65 accoprding to DIN 40050
Emergency control :
Closed position in case of power cut off
Control voltage :
0,7 V to 10 V
Tension Nominale:
Tension Mini-Maxi batterie:
Service S2:
Service S3:
Courant de consommation:
Indice de protection:
Commande de secours:
Tension de commande:
Reference: C5089984
10 l / min
Max. flow :
Max. Pressure :
Outlet Max. pressure :
Reference: C5089985
27 l / min
10 l / min
250 bar
8 bar
Max. flow :
27 l / min
Max. Pressure :
200 bar up to 18l/min
Outlet Max. pressure : 4 bar
Pressure Loss
Perte de charge
Pressure - Pression (Bar)
Pressure - Pression (Bar)
24 V
16,8 V - 28,8 V
5 min
20% de 10 min
300mA Maxi
IP65 suivant DIN 40050
Fermée en cas de coupure du courant
0,7 V à 10 V
Pressure Loss
Perte de charge
25
20
15
10
5
0
0
3
6
Flow - Débit (l/min)
9
12
15
18
Flow - Débit (l/min)
21
24
27
Progressivity according to Voltage
Progressivité en fonction de la Tension
Flow - Débit (l/min)
Progressivity according to Voltage
Progressivité en fonction de la Tension
Flow - Débit (l/min)
24
18
12
6
0
0
Voltage - Tension (Vdc)
MINI POWER - PACKS
MINI CENTRALES
2G
2
4
6
Voltage - Tension (Vdc)
- 29 -
8
10
VALVES AND SPECIFICATIONS
VALVES ET SPECIFICATIONS
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
Directional Control Valves
CETOP 3
Distributeurs
194 (4 way / 3 pos)
141 ( 4 way / 2
pos)
Plug DIN 43650
Fiche DIN 43650
80
Note! Coils are rated for 50/60Hz
40
Dual Flow Control
Limiteur de debit double
40
160
Manual Overrides
Dual PO Check
Clapet Anti-Retour double
108
161
Symbols
Symboles
Voltage
Tension
References
Références
12 VDC
24 VDC
110 VAC
220 VAC
24 VAC
K5091658
K5091659
K5091660
K5091661
K5091662
Dual PO
Checks
Clapet AntiRetour double
K5093053
Dual Flow
Limitor
Limiteur de debit
double
K5093054
Symbols
Symboles
Voltage
Tension
References
Références
12 VDC
24 VDC
110 VAC
220 VAC
24 VAC
K5091673
K5091674
K5091675
K5091676
K5091677
12 VDC
24 VDC
110 VAC
220 VAC
24 VAC
K5091668
K5091669
K5091670
K5091671
K5091672
12 VDC
24 VDC
110 VAC
220 VAC
24 VAC
K5091663
K5091664
K5091665
K5091666
K5091667
12 VDC
24 VDC
110 VAC
220 VAC
24 VAC
K5091678
K5091679
K5091680
K5091681
K5091682
REMOTE CONTROL
SPECIFICATIONS
HPI Solution
- With more than 10 m of range, it allows any
movement in the work area.
- Accidental operations are prohibited by the
security push button.
- 2 and 4 way models available. All kinds of
applications are conceivable.
MINI POWER - PACKS
MINI CENTRALES
2G
Operating Frequency: 433.92Mhz, less than 10mW
Operating Modes:
MonoStable:
The contact is maintained as long
as the pushbutton is pressed
BiStable (default): Each order requires a counter order.
Contact maintained for dwell time.
Dwell time:
In BiStable mode a timer controls the
period of contact if a counter order is not
received.
Motor: 30 seconds
Valve: 120 seconds
Power Supply:
10 to 30 Vdc
Power Consumption: Receiver when inoperative: 15 mA
Receiver when working:
70 mA
Relay Output:
At 12Vdc: 15 amps
At 24Vdc: 10 amps
Enclosure rating:
Receiver: IP65 Wiring: PE IP68
Environment: -20°C to +50°C
- 30 -
REPLACEMENT PARTS: LISTING
Hydroperfect Intl. Inc.
North America
Tel: (905) 791-3388
Fax: (905) 791-7322
REPLACEMENT PARTS - MINI 2G POWERPACKS
MOTORS
AC
0.25 - 5.0 HP
DS1
1,# kW 12VDC
DS2
1,5 kW 24VDC
BK1
2,1 kW 12VDC
BK2
2,2 kW 24VDC
BS2
2,2 kW 24VDC
CI2
3,0 kW 24VDC
See Pg. 14
114133
114134
114806
113349
113305
111895
RELAYS
RELAY: 80 AMP - 12VDC
RELAY: 80 AMP - 24VDC
RELAY: 150 AMP - 12VDC
RELAY: 150 AMP - 24VDC
BRAID CONNECTOR
E5080303
E5074322
E5085534
E5085533
101809
BELLHOUSING
BELLHOUSING: 56C
HPI-9471
COUPLINGS
COUPLING: AC 5/8” shaft
COUPLING: AC Insert
COUPLING: AC Pump half
COUPLING: DS, BK, BS
COUPLING: CI
L075-5/8-3/16
L075 - SOX
L075 - 10mm
111182
104971
PUMP SUPPORTS & INTERNAL PARTS
1CC
(L20 SHAFT)
E5091579
2CC
(For AC Motors)
E5091580
3CC
“
E5091581
4CC
“
E5091582
5CC
“
E5091583
6CC
“
E5091584
1CC
(L40 SHAFT)
E5091573
2CC
(For DC Motors)
E5091574
3CC
“
E5091575
4CC
“
E5091576
5CC
“
E5091577
6CC
“
E5091578
CHECK VALVE
K5089116
RELIEF VALVE 10 - 300 BAR K5093458
RESERVOIR PARTS
CLAMP: T, E, A, H ,B, S, Z
COLLERETTE: C, U
COLLERETTE: R, K, D
COLLERETTE: G, Y
COLLAR: Ya
ELBOW
K5073875
K5091604
K5091605
K5093422
MTM/2761
110232+A
FILTRATION
STRAINER 90 MICRON
STRAINER 300 MICRON
INLET TUBING
INLET CLAMP
RETURN DIFFUSER 300 MIC
RETURN FILTER 10 MIC
RETURN HOSE
RETURN CLAMP
STR-050
K5072445
109810
OET 16701005
E5072445
RTR-050
AU05-008-BK
OET 10500012
MINI POWER - PACKS
MINI CENTRALES
2G
RESERVOIRS
T
1,1 L
E
1,5 L
A
2,0 L
H
2,5 L
B
3,0 L
S
4,0 L
Z
6,0 L
C
5,0 L
U
6,0 L
R
5,0 L
K
7,5 L
D
10,0 L
Y
14,0 L HORIZONAL
Y
14,0 L VERTICAL
G
6,3 L
Qa
6,5 L
Da
12,0 L
La
18,0 L
Ma
30,0 L
Na
44,0 L
Oa
70,0 L
Ds
12,0 L
Ms
34,0 L
Ya
12,0 L
K5080246
K5061100
K5061110
K5061120
K5061130
K5087273
K5080008
K5077650
K5074035
K5061380
K5061390
K5061400
K5093793
K5083378
NG6,5
NG12
NG20
NG30
NG44
NG70
Ds Tank
Ms Tank
Ya Tank
VALVE BLOCKS AND ACCESSORIES
PORTS 3 & 4
10L POPPET VALVE BLOCK
K5091997
WITH PORT #6
K5090149
20 L POPPET VALVE BLOCK
K5091998
WITH PORT #6
K5090148
DIRECTIONAL VALVE BLOCK
4 way, 2 position
K5090020
4 way, 3 position
CETOP 3 BASEPLATE
-SPACER
-O-RING
-BANJO BOLT, MAIN BLOCK
-BANJO BOLT, SPACER
-CAP
2 X SINGLE ACTING BLOCK
-SPACER
-O-RING
-ADAPTOR M14x1.5 TO BSPP
-BANJO BOLT WITH CAP
INLINE BLOCK (LOAD HOLDING)
-ADAPTOR M14 TO BSPP
-BANJO BOLT
-O-RING
PORT ADAPTORS / MISC ITEMS
PLUG: PORTS 1 & 2
BONDED SEAL, M14
PORT 1&2 ADAPTOR: #6 JIC MALE
PORT 1&2 ADAPTOR: 1/4” FNPT
PORT 1&2 ADAPTOR: #6 SAE
HPI-3961
HPI-3934
MNOR019X2
HPI-3910-2
HPI-3894
HPI-3880-2
E5071414
HPI-3930
MNOR019X2
E5063190
108199
CARTRIDGE VALVES, 2 WAY
VNF2G: 12 VDC (normally closed) C5084513
VNF2G: 24 VDC
“
C5084514
VNF2G: 24VRAC
“
C5094325
VNF2G: 115 VRAC
“
C5086855
VNF2G: 230 VRAC
“
C5086854
VNF: 12 VDC
(normally closed)
C5035300
VNF: 24 VDC
“
C5035310
VNF: 24 VRAC
“
C5072507
VNF: 115 VRAC
“
C5048410
VNF: 230 VRAC
“
C5048420
VNO: 12 VDC
(normally open)
C5068370
VNO: 24 VDC
“
C5068380
VNO: 24 VRAC
“
C5072505
VNO: 115 VRAC
“
C5071251
VNO: 230 VRAC
“
C5071252
VLB: 12 VDC
(double check)
C5067470
VLB: 24 VDC
“
C5067480
VLB: 24 VRAC
“
C5072509
VLB: 115 VRAC
“
C5071260
VLB: 230 VRAC
“
C5071261
CARTRIDGE VALVES, PROPORTIONAL
VNF: 10 l/m
C5089984
VNF: 27 l/m
C5089985
COILS & CONNENCTORS:
VNF2G COIL: 12 VDC
112344
VNF2G COIL: 24 VDC
112345
VNF2G COIL: 24 VRAC
VNF2G COIL: 115 VRAC
112809
VNF2G COIL: 230 VRAC
112808
VNF/VNO/VLB COIL: 12 VDC
E5072140
VNF/VNO/VLB COIL: 24 VDC
E5072141
VNF/VNO/VLB COIL: 24 VRAC
E5072513
VNF/VNO/VLB COIL: 115 VRAC
E5072145
VNF/VNO/VLB COIL: 230 VRAC
E5072146
DIN CONNECTOR - DC COILS
102291
DIN CONNECTOR - AC COILS
104097
(connector is included with AC Coils)
PRESSURE COMP. FLOW CONTROLS
1,1 l/m
(PORT 31 STYLE)
E5073714
1,4 l/m
“
E5073433
2,2 l/m
“
E5073752
3,1 l/m
“
E5073434
4,1 l/m
“
E5073749
5,4 l/m
“
E5073435
6,6 l/m
“
E5073437
8,0 l/m
“
E5073644
9,5 l/m
“
E5073439
E5063190
11,2 l/m
“
E5073441
108199
“
E5073729
MNOR019X2 13,2 l/m
15,3 l/m
“
E5073442
17,6 l/m
“
E5073443
20,0 l/m
“
E5073444
“
E5073590
9500-14MM 22,3 l/m
OM14-J6
OM14-N025
OM14-S6
PLEASE NOTE! PARTS LISTED ON THIS PAGE MAY DIFFER FOR UNITS ASSEMBLED
IN FRANCE. PLEASE CONTACT HPI CANADA FOR FURTHER INFORMATION.
- 31 -
Hydroperfect Intl. Inc.
North America
HYDRAULIC INNOVATION AT YOUR SERVICE
Tel: 1-800 451-5284 Fax: (905) 791-7322
custserv@hpicanada.com
www.hpicanada.com / www.hpi.tm.fr
Cartridge, Spool and CETOP 3 Valves
Integrated Pump/Motor valve units
Pumps , Motors & Flow Dividers
Micro and Mini Pump Motor Combinations
Custom OEM Solutions
Mini Powerpacks
Micro Powerpacks
Download