TrustedTM PD-T8314 TrustedTM Fibre TX/RX Unit Introduction TM TM The Trusted Fibre TX/RX Unit T8314 is designed to extend the Trusted Expander Bus over TM distances of up to 10km. This enables a Trusted Expander Chassis to be located remotely from the TM Trusted system. Note: It is recommended that if a remote Expander Chassis is to be located more than 2km from the Controller Chassis, the route of the cable is surveyed. The Expander Bus is extended by means of a communications link using a single mode fibre-optic TM cable. The Trusted Fibre TX/RX Unit converts the differential signals of the copper-based Expander Bus to a fibre-optic signal for transmission via the single mode cable. Three totally independent pairs TM of Trusted Fibre TX/RX Units provide a non-interfering ‘Grey Channel’ approach to safety. Features • Dual 24V dc diode ORed power supply. • Easy installation (Din rail mounting). • Communications over a distance of 10km. • Independent units therefore easily maintained. • SC type connectors to two fibres (Tx & Rx). • Low power consumption. Issue 10 Sep 08 PD-T8314 1 TrustedTM Fibre TX RX Unit T8314 Issue Record Issue Number Date Revised by Technical Check Authorised by Modification 7 Sep 05 J W Clark 8 Dec 06 N Owens I Vince P Stock Corrections 9 Nov 07 N Owens I Vince P Stock Optical Tx/Rx power Format specifications 10 Sep 08 Issue 10 Sep 08 N Owens A Holgate PD-T8314 P Stock Max length difference 2 TrustedTM Fibre TX RX Unit T8314 Figure 1 T8314 Photo Issue 10 Sep 08 PD-T8314 3 TrustedTM Fibre TX RX Unit T8314 Table of Contents 1. Description......................................................................................................................................7 2. Installation ......................................................................................................................................9 3. Associated Trusted 4. Cable Specification.......................................................................................................................10 5. Pin connections ............................................................................................................................11 TM Cable Selection ...........................................................................................9 5.1. Power Connection Details..........................................................................................................11 5.2. Expander Bus Connection Details .............................................................................................11 6. Specifications ...............................................................................................................................12 Figures Figure 1 T8314 Photo ...............................................................................................................................3 TM Fibre TX/RX Unit Block Diagram ...............................................................................7 TM Fibre TX/RX Unit Configuration .................................................................................8 Figure 2 Trusted Figure 3 Trusted Tables TM Table 1 Associated Trusted Cable Selection ........................................................................................9 Table 2 Cable Specification ....................................................................................................................10 Table 3 Power Connection Details .........................................................................................................11 Table 4 Expander Bus Connection Details .............................................................................................11 Issue 10 Sep 08 PD-T8314 4 TrustedTM Fibre TX RX Unit T8314 Notice The content of this document is confidential to ICS Triplex Technology Ltd. companies and their partners. It may not be given away, lent, resold, hired out or made available to a third party for any purpose without the written consent of ICS Triplex Technology Ltd. This document contains proprietary information that is protected by copyright. All rights are reserved. Microsoft, Windows, Windows 95, Windows NT, Windows 2000, and Windows XP are registered trademarks of Microsoft Corporation. The information contained in this document is subject to change without notice. The reader should, in all cases, consult ICS Triplex Technology Ltd. to determine whether any such changes have been made. From time to time, amendments to this document will be made as necessary and will be distributed by ICS Triplex Technology Ltd. Information in this documentation set may be subject to change without notice and does not represent a commitment on the part of ICS Triplex Technology Ltd. The contents of this document, which may also include the loan of software tools, are subject to the confidentiality and other clause(s) within the Integrator Agreement and Software License Agreement. No part of this documentation may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose, without the express written permission of ICS Triplex Technology Ltd. Disclaimer The illustrations, figures, charts, and layout examples in this manual are intended solely to illustrate the text of this manual. The user of, and those responsible for applying this equipment, must satisfy themselves as to the acceptability of each application and use of this equipment. This document is based on information available at the time of its publication. While efforts have been made to be accurate, the information contained herein does not purport to cover all details or variations in hardware or software, nor to provide for every possible contingency in connection with installation, operation, or maintenance. Features may be described herein which are present in all hardware or software systems. ICS Triplex Technology Ltd. assumes no obligation of notice to holders of this document with respect to changes subsequently made. ICS Triplex Technology Ltd. makes no representation or warranty, expressed, implied, or statutory with respect to, and assumes no responsibility for the accuracy, completeness, sufficiency, or usefulness of the information contained herein. No warranties of merchantability or fitness for purpose shall apply. Issue 10 Sep 08 PD-T8314 5 TrustedTM Fibre TX RX Unit T8314 Revision and Updating Policy All new and revised information pertinent to this document shall be issued by ICS Triplex Technology Ltd. and shall be incorporated into this document in accordance with the enclosed instructions. The change is to be recorded on the Amendment Record of this document. Precautionary Information WARNING Warning notices call attention to the use of materials, processes, methods, procedures or limits which must be followed precisely to avoid personal injury or death. CAUTION Caution notices call attention to methods and procedures which must be followed to avoid damage to the equipment. Notes: Notes highlight procedures and contain information to assist the user in the understanding of the information contained in this document Warning RADIO FREQUENCY INTERFERENCE Most electronic equipment is influenced by Radio Frequency Interference (RFI). Caution should be exercised with regard to the use of portable communications equipment around such equipment. Signs should be posted in the vicinity of the equipment cautioning against the use of portable communications equipment. MAINTENANCE Maintenance must be performed only by qualified personnel, otherwise personal injury or death, or damage to the system may be caused. Caution HANDLING Under no circumstances should the module housing be removed. Associated Documents Product Descriptions (PD) provide product specific information. The Safety Manual contains the recommended safety requirements for the safety system design. The PD8082B – Toolset Suite provides specific guidance on system configuration and application generation. The Operator and Maintenance Manual contains general guidelines on maintenance and diagnostic procedures. For technical support email: support@icstriplex.com Issue 10 Sep 08 PD-T8314 6 TrustedTM Fibre TX RX Unit T8314 1. Description TM The Trusted Fibre TX/RX Unit T8314 is designed to be DIN rail mounted in the rear area of a TM cabinet/bay containing the Trusted Controller Chassis T8100. A block diagram of the Unit is shown in Figure 2 below: Figure 2 Trusted TM Fibre TX/RX Unit Block Diagram TM The Unit provides a communications connection interface between the Trusted and a remote Expander Chassis. Controller Chassis TM The Positive Emitter Coupled Logic (PECL) signal from the Trusted Expander Interface Module in TM the Controller Chassis is connected to the Unit by a Trusted Expander Cable TC-302. The signal is fed through an isolator, then filtered and terminated before being connected to the PECL input of the fibre-optic transceiver. The fibre-optic signal is transmitted to a similar Unit at the remote end via a Single Mode Fibre-Optic Cable. The fibre-optic transceiver at the remote end of the link converts the TM signal back to a PECL signal before transmitting it to the Trusted Expander Processor Module via a TM Expander filter/termination circuit, isolator and ‘F’ filter. Signals originating from the Trusted Processor Module in the remote Expander Chassis are processed in the same manner. Issue 10 Sep 08 PD-T8314 7 TrustedTM Fibre TX RX Unit T8314 TM Figure 3 below shows the configuration of the Unit within a Trusted Chassis. Figure 3 Trusted TM System using a remote Expander Fibre TX/RX Unit Configuration Six Units and six fibres are required for each remote link with three located at each end. A dual 24V dc power philosophy is employed allowing the user to supply each Unit with dual power feeds. Individual Units require no configuration prior to installation within a remote communications link. Each Unit operates in a stand-alone mode allowing replacement without interrupting the operation of the TM Trusted System. There are no diagnostics available, but the quality of communications may be checked by using the Expander Interface and Processor diagnostics via the application program. Note: Data is transmitted along the dual fibre-optic link at a rate of 250MHz. Signal skew will take place but it must not exceed 80ns, which equates to a cable length difference of 15 metres. This requires that synchronisation must take place at the start and end of each transmission. Skew not exceeding 80ns can be guaranteed for distances up to 2km. For distances greater than 2km, cable routes must be surveyed to ensure that the propagation time difference between the shortest and longest distance of the three links is less than 80ns. Issue 10 Sep 08 PD-T8314 8 TrustedTM Fibre TX RX Unit T8314 2. Installation TM The Trusted Fibre TX/RX Unit T8314 may be mounted on either of the TS32 or TS35 DIN rails in the horizontal or vertical position as required. Note: Allow a minimum of 200mm on either side of the Unit to allow for the fibre cable bend radius. This bend radius may vary depending upon the type of cable chosen by the user. 3. Associated TrustedTM Cable Selection Cable Type Description TC-302-01 250 Mbits/s Remote Expander Outgoing Cable from T8312 to T8314 TC-303-01 250 Mbits/s Remote Expander Incoming Cable from T8314 to T8310 Table 1 Associated Trusted TM Cable Selection Note: ICS Triplex recommends that BICC Brand-Rex Helios Optical Single Mode Fibre Cable be TM used to inter-connect the Trusted Fibre TX/RX Units. The cable must be configured using ‘SC’ type connectors. Issue 10 Sep 08 PD-T8314 9 TrustedTM Fibre TX RX Unit T8314 4. Cable Specification TM The specification of cables used to inter-connect Trusted Parameter Value Cable type Single Mode 1300 Fibre TX/RX Units is detailed below. Min 1270 Dispersion @ 1300nm Bandwidth Unit nm Attenuation @ 1300nm Cut-off Wavelength Max 0.38 dB/km 1360 nm 3.5 nm 600 MHz Spectral Width 2.5 nm Variation in Refractive Index 0.5 % Transmitter power -15 dBm ( into the fibre cable ) Receive sensitivity -28 dBm ( minimum power budget for optical link ) Laser Output Optical Eye Opening Compliant With TR-NWT-000253 and ITU-T Recommendations G.957 Connector Type SC Cores 6 Table 2 Cable Specification Issue 10 Sep 08 PD-T8314 10 TrustedTM Fibre TX RX Unit T8314 5. Pin connections 5.1. Power Connection Details Pin Service 1 +24V dc 1 2 0V1 3 0V2 4 +24V dc 2 Table 3 Power Connection Details Note: The 24V dc supplies are diode ORed to allow the Unit to be powered from a dual or single source as required. 5.2. Expander Bus Connection Details Pin Service 1 TX+ 2 TX- 3 RX- 4 RX+ Table 4 Expander Bus Connection Details Issue 10 Sep 08 PD-T8314 11 TrustedTM Fibre TX RX Unit T8314 6. Specifications Voltage Range 18 to 32V dc Power Consumption (Max) 1.7W Transmitter power -15 dBm minimum Receiver sensitivity -28 dBm Maximum propagation time difference 80ns Maximum fibre length difference 15m Operating Temperature -5°C to 60°C (23°F to 140°F) Non-operating Temperature -25°C to 70ºC (-25°F to 158°F) Operating Humidity 5 to 95% RH Environmental Specifications Refer to Document 552517 Dimensions Height Width Depth 84mm (3.3ins) 110mm (4.3ins) 40mm (1.6ins) Weight 320g (0.7lbs.) Issue 10 Sep 08 PD-T8314 12 TrustedTM Fibre TX RX Unit T8314 This page is intentionally blank Issue 10 Sep 08 PD-T8314 13