SINGLE-FAMILY RESIDENTIAL (R-0) Notes: 1. A site plan is required prior to the issuance of a building permit. 2. No side or rear yard required when adjacent to a canal or body of water. 3. No projection closer than 12 inches to a common property line. Projections include: roof eaves (up to 36”), window sills, belt courses, and other architectural features. 4. Sign, fence, and wall regulations apply. 5. Boat slips, boat docks, shade covers, or decking constructed over water, do not require a setback provided the improvement built over water is part of the platted lot. Minimum Lot Standards 6. One-family attached dwelling units require a zero-foot (0’) rear yard setback when abutting another one-family attached dwelling. Setbacks 7. Accessory buildings are permitted in the rear yard. A three-foot (3’) rear yard and side yard setbacks are required, unless abutting alley or street then no required rear yard setback. 8. Building setback may conflict with Fire Code. Refer to Fire Code to determine final building and fire code setbacks. Area: Width: Depth: Front: Side: Rear: 5,000 square feet 50-feet 100-feet 20-feet 3 – 5 feet 10-feet Building Height Maximum: 50-feet, measured from base flood elevation Parking One (1) space per dwelling unit Landscaping Refer to “Article 9: Landscaping” of the City’s Land Development Regulations. City of Galveston 823 Rosenberg Galveston, TX 77550 f Galveston ARTICLE 3, District Yard, Lot and Setback Standards Page 3-05 SINGLE-FAMILY RESIDENTIAL (R-1) Notes: 1. A site plan is required prior to the issuance of a building permit. 2. No side or rear yard required when adjacent to a canal or body of water. 3. No projection closer than 12 inches to a common property line. Projections include: roof eaves (up to 36”), window sills, belt courses, and other architectural features. 4. Sign, fence, and wall regulations apply. 5. Boat slips, Boat docks, shade covers, or decking constructed over water do not require a setback provided the improvement built over water is part of the platted lot. 6. One-family attached dwelling units require a zero-foot (0’) rear yard setback when abutting another one-family attached dwelling. 7. Accessory buildings are permitted in the rear yard. A three-foot (3’) rear yard and side yard setbacks are required, unless abutting alley or street then no required rear yard setback. 8. Unlimited height from the east property line of Stewart Beach and eastward. 9. Building setback may conflict with Fire Code refer to Fire Code to determine final building and fire code setbacks. Minimum Lot Standards Area: Width: Depth: 5,000 square feet 50-feet 100-feet Setbacks Front: Side: Rear: 20-feet 3 – 5 feet 10-feet Building Height Maximum: 50-feet, measured from base flood elevation Parking One (1) space per dwelling unit Landscaping Refer to “Article 9: Landscaping” of the city’s Land Development Regulations. City of Galveston 823 Rosenberg Galveston, TX 77550 f Galveston 823 Rosenberg Galveston, TX ARTICLE 3, District Yard, Lot and Setback Standards 77550 Page 3-06 DUPLEX TO EIGHT-PLEX (R-2) Notes: 1. A site plan is required prior to the issuance of a building permit. 2. No side or rear yard required when adjacent to a canal or body of water. 3. No projection closer than 12 inches to a common property line. Projections include: roof eaves (up to 36”), windowsills, belt courses, and other architectural features. 4. No side or rear yard required when adjacent to an alley or right-of-way. 5. Average Front Yard Setback: Where 30% of buildings on one side of a street, on a single block, are built with a 10’ or less front yard setback, the average setback of the structures shall be the required setback. 6. Accessory buildings are permitted in the rear yard. A three-foot (3’) rear yard setback required, unless abutting alley or street then no required rear yard setback. 60% of required rear yard setback area can be occupied by accessory building. 7. Building setback may conflict with Fire Code refer to Fire Code to determine final building and fire code setbacks. Minimum Lot Standards Area: Width: Depth: 4,000 square feet 40-feet 100-feet Setbacks Front: Side: Rear: 20-feet 3 – 5 feet 10-feet Building Height Maximum: 50-feet, measured from base flood elevation Parking Single Family: Multi-Family: Lodging: Non-Residential: Minimum 1 per unit Minimum 1.5 per unit Minimum and maximum .75 per unit One (1) per 300 square feet of gross floor area Landscaping Refer to “Article 9: Landscaping” of the City’s Land Development Regulations. City of Galveston 823 Rosenberg Galveston, TX 77550 f Galveston ARTICLE 3, District Yard, Lot and Setback Standards Page 3-07 MULTI-FAMILY RESIDENTIAL (MF) Notes: 1. A site plan is required prior to the issuance of a building permit. 2. No side or rear yard required when adjacent to a canal or body of water. 3. No projection closer than 12 inches to a common property line. Projections include: roof eaves (up to 36”), window sills, belt courses, and other architectural features. 4. 40% of required landscape for multi-family projects shall be placed in front yard setback. 5. Average Front Yard Setback: Where 30% of buildings on one side of a street, on a single block, are built with a 10’ or less front yard setback, the average setback of the structures shall be the required setback. 6. Accessory buildings are permitted in the rear yard. A three-foot (3’) rear yard setback required, unless abutting alley or street then no required rear yard setback. 7. A five-foot (5’) masonry wall shall be constructed between a multi-family project and an R-1 zone or single-family use. 8. Approved fence materials include: wood, concrete, or rod iron. 9. Individual side yard increased to 10’ if abutting an R-1 zone or single-family use. 10. Building setback may conflict with Fire Code. Refer to Fire Code to determine final building and fire code setbacks. Minimum Lot Standards Area: Width: Depth: 4,000 square feet 40-feet 100-feet Setbacks Front: Side: Rear: 20-feet 3 – 5 feet 10-feet Building Height Maximum: 100-feet, measured from base flood elevation Parking Single Family: Multi-Family: Lodging: Non-Residential: Minimum 1 per unit Minimum 1.5 per unit Minimum and maximum .75 per unit One (1) per 300 square feet of gross floor area Landscaping Refer to “Article 9: Landscaping” of the City’s Land Development Regulations. City of Galveston 823 Rosenberg Galveston, TX 77550 f Galveston ARTICLE 3, District Yard, Lot and Setback Standards Page 3-08 URBAN NEIGHBORHOOD (UN) Notes: 1. A site plan is required prior to the issuance of a building permit. 2. No side or rear yard required when adjacent to a canal or body of water. 3. New buildings shall utilize building elements and details to achieve a pedestrian‐oriented public realm. 4. Compatibility is not meant to be achieved through uniformity, but through the use of variations in building elements to achieve individual building identity. 5. Building facades shall include appropriate architectural details and ornament to create variety and interest. 6. All primary entrances shall be oriented to the public sidewalk for ease of pedestrian access. Secondary and service entrances may be located from internal parking areas or alleys. 7. Encroachments: canopies, signs, awnings, balconies and similar overhangs may encroach over any required setback, build-to-line or the sidewalk as long as the vertical clearance is a minimum of eight-feet (8’). In no case shall an encroachment be located over any side or rear property line. 8. 9. Average Front Yard Setback: Where 30% of buildings on one side of a street, on a single block, are built with a 10’ or less front yard setback, the average setback of the structures shall be the required setback. Building setback may conflict with Fire Code. Refer to Fire Code to determine final building and fire code setbacks. CONTINUE TO NEXT PAGE. Minimum Lot Standards Area: 2,500 square feet Width: 0-feet Depth: 0-feet Setbacks Front-Build-to-Line: Side: Rear: 0 – 5 feet 0 – 5 feet 0 – 5 feet Building Height Maximum: 50-feet, measured from base flood elevation Parking: Residential: Non-Residential: Lodging: Parking Location: Minimum 0 per unit; Maximum 1.5 per unit Minimum 1 per 1,500 sq. ft. gross floor area Minimum .75 per unit On/Off site Landscaping Refer to “Article 9: Landscaping” of the City’s Land Development Regulations. 14th Street Corridor City of Galveston 823 Rosenberg The table on Page 3-12 will govern land uses within the 14th Street UN district. Galveston, TX 77550 f Galveston ARTICLE 3, District Yard, Lot and Setback Standards Page 3-09 URBAN NEIGHBORHOOD (UN) Notes (cont): Design Standards Applicable to Commercial Structures and Uses: 10. Limited Use Standards apply where applicable. 11. Commercial uses and structures limited to numbered streets in the UN district. 12. Commercial and Mixed‐Use building facades shall be designed with a distinct base, middle and top and shall maintain the alignment of horizontal elements along the block. 13. Doors or windows forming regular patterns of openings, some accentuated by balconies. 14. Primary entrance doors for all buildings shall be facing Street facing façades. 15. If driveway and/or off‐street service loading and unloading access is provided cross access easements shall be required when adjoining properties are undeveloped. 16. There shall be no blank walls greater than 25 ft. in width. 17. Bed and Breakfast: Maximum number of guest rooms is nice (9). Maximum length of stay is 28 days. Must be owner or manager occupied. 18. Auto Repair and Auto Sales are permitted use on property legally described “ABST 628 Page 122 Lots 8 thru 9 & E 6.33-ft of Lot 10 (2010-1) SW Block 90 Galveston Outlots.” Design Standards for Commercial Structures Base Flood Elevation st 15’ floor to ceiling nd 2 Floor & Up: 10’ floor to ceiling Build Material: Stone, brick, stucco, shiplap, fibrous cement board imitating wood shiplap Door Locations: Primary entrance doors for all buildings shall be facing street. Balconies: Required at 2nd and 3rd floor On-site parking: Rear of building, enclosed if on front and access is available Fencing: Chain-link prohibited (cyclone) Windows: Upper floors shall be a minimum of 20% of each upper floor façade measured between 3ft. and 9ft. above each finished floor Window Type: Vertical orientation Dry Flood Proofing: Dry Flood Proofing may be used to protect the space inside the building below the Base Floor Elevation if the ground floor entrance is not above the base flood elevation. Stairs and ramps may be incorporated inside the building envelop to transition to a higher level. In the case that dry flood proofing is not feasible, exterior stairs and ramps or other impact approaches shall only be permitted. Exterior ramps and stairs when used shall be positioned to minimize the accessibility of the commercial storefront. 1 Floor Height: Exterior Ramps and Stairs: If an exterior ramp is required in order to accommodate access to a raised Base Flood Elevation, the ramp shall be oriented perpendicular to the primary facade in order to minimize the visual impact and pedestrian accessibility of the primary facade. If an exterior stair is required to accommodate access to a raised Base Floor Elevation, the steps shall be located towards the primary entrance along the primary façade. ARTICLE 3, District Yard, Lot and Setback Standards Page 3-10 URBAN NEIGHBORHOOD (UN) P = permitted use ; L = limited use ; S = specific use review San Jacinto Neighborhood East side of 23rd Street – West side of 6th Street and North side of Seawall Boulevard – South side of Broadway Corner Stores – Permitted Structures: 1128, 1425, 1516 – AVENUE K 1027, 1301, 1404, 1509, 1528 – AVENUE L 1201, 1327 – AVENUE M 1701 – AVENUE M ½ 1728, 1902 – AVENUE N 1502, 1702, 1828, 1902 – AVENUE O 2001 – AVENUE 0 ½ th 1212, 1502 – 13 STREET th 1104, 1213 – 14 STREET th 1104 — 15 STREET th 1513, 1515 – 19 STREET st 1302, 1502, 1506, 1624, 1801 – 21 STREET Permitted Commercial Land Use: th th th rd Located on 8 , 10 , 14 , and 23 Street Corner Store/Commercial Structure Standards: Gross Floor Area Limited to 2,500 sq. ft. Additional Standards: th Surface parking lots permitted on 10 Street Williams-Borden Neighborhood Association th th West side of 35 Street – East side of 39 Street and South side of Avenue O – North side of Avenue S Corner Stores – Permitted Structures: 3827 — AVENUE O 3627, 3702 — AVENUE R 3828 — AVENUE S th 2005, 2427 — 35 STREET th 1702, 1712 — 37 STREET th 1710, 2414 — 39 STREET Kempner Park Neighborhood th th West side of 25 Street – East side of 39 Street and South side of Avenue O – South side of Avenue S Corner Stores – Permitted Structures: 2528, 2602, 2628, 2728, 2892, 2927, 3028, 3228 — AVENUE Q 3227, 3228, 3307 — AVENUE R 3201-5 — AVENUE R ½ 3128, 3402, 3428, 3501 — AVENUE S th 2102 — 26 STREET rd 2223, 3230 — 33 STREET th 2005, 2201, 2427, 2500-2550 — 35 STREET ARTICLE 3, District Yard, Lot and Setback Standards Agricultural Land Use Agriculture/Urban Farming P Residential Land Uses Accessory Dwelling Unit L Bed and Breakfast L Cottage Food P Child Care Facility, Residential (Day Care) L Community Garden L Home Based Occupation/Business L Hospital House Establishment L Live-Work Unit L Personal Care Homes (DADS) P Short Term Rental Residential Dwelling P Single-Family Attached L Single-Family Detached P Commercial Land Uses Adult Day Care Alcoholic Beverage Sales, Liquor Store or Package L S Child Care Facility, Day Care (Commercial) L Cleaning / laundry pick-up station L College / University / Vo-Tech P Commercial Amusement/Recreation Indoor L Commercial Lodging (Hotel) S Library P Music Instruction P Medical Office / Clinic / Lab L Nursery or Greenhouse, Retail L Nursing / Convalescent Home L Office L Parking Structure/Lot to Main Use L Personal Fitness or Music Instruction L Pet Grooming Services L Place of Public/Private Assembly L Private Club S Professional Services, Instruction or Counseling L Public Safety Facility P Recreation Indoor L Recreation Outdoor L Restaurant, No Drive-In / Through L Retail - Commercial P School: Private L Page 3-11 TRADITIONAL NEIGHBORHOOD (TN) Notes: 1. A site plan is required prior to the issuance of a building permit (phasing developments must include a phasing plan.) 2. No side or rear yard required when adjacent to a canal or body of water. 3. No side yard required for end units which face a street, plaza, park. 4. Minimum tract size 50 acres. 5. Roofs may overhang zoning setback lines. 6. All utilities shall be placed underground. 7. Alternative street designs must meet design standards established by Institute of Transportation Engineers. 8. Zero lot line houses may have one wall, a minimum of one-foot (1’) from the side property line, and no other side wall or minimum of seven-feet (7’) from the other side property line, such that each house side wall is a minimum of eight-feet (8’) from the adjacent house side wall. Minimum Lot Standards Area: Width: Depth: Setbacks 9. Utility easements and drainage shall be provided as determined by the City Engineer. Front: Side: 10. Unlimited height from the east property line of Stewart Beach and eastward. Rear: 11. 12. Designation Procedure: Zoning amendment Site Plan, Phasing Plan (staff approval) Subdivision Plat Appeal to Planning Commission if denied Appeal to City Council, if Planning Commission denial. Permitted Uses: Carriage houses, max 350 square feet Mixed-use buildings Private streets 13. Building setback may conflict with Fire Code. Refer to Fire Code to determine final building and fire code setbacks. 1,500 square feet 24-ft; 18-ft for single-family attached 0-ft 0-feet 5-feet; 0-ft for single-family attached and commercial 10-feet; 0-ft for commercial Building Height Maximum: 60-feet, measured from base flood elevation Multi-Family: 100-ft, measure from base flood elevation Parking Residential: Non-Residential: One (1) per dwelling unit One (1) per 300 square feet gross floor area Lodging: Minimum and maximum .75 per unit Required parking may be located Off-Site Landscaping Refer to “Article 9: Landscaping” of the City’s Land Development Regulations. City of Galveston 823 Rosenberg Galveston, TX 77550 f Galveston ARTICLE 3, District Yard, Lot and Setback Standards Page 3-12 RESORT-RECREATION (RES/REC) Notes: 1. A site plan is required prior to the issuance of a building permit. 2. No side or rear yard adjacent to a canal or body of water. 3. Side yard may be reduced to three-feet (3’) with appropriate fire rated wall. 4. If property fronts Seawall Boulevard, 0-10’, build-to-line, flag shaped lots exempt from this provision 5. Unlimited height from the east property line of Stewart Beach and eastward. 6. Lots on Southside of Seawall Boulevard, zerofoot (0’) setback on Gulf side of lot. 7. Building setback may conflict with Fire Code. Refer to Fire Code to determine final building and fire code setbacks. Minimum Lot Standards Area: Width: Depth: 4,000 square feet 40-feet 50-feet Setbacks Front: Side: Rear: 0 – 10 feet 5-feet 10-feet Building Height Maximum: 120-feet, measured from base flood elevation Exception: 70-ft, measured from base flood elevation for property legally described as “ABST 628, M. Menard Survey, Park OF Lots 2 thru 4 & 8 thru 13 (8-1), Block 125 & Adjacent Abandoned Alley & Streets in Galveston” Parking Residential: Non-Residential: Lodging: City of Galveston 823 Rosenberg Galveston, TX 77550 Minimum one (1) per unit One (1) per 300 square feet of gross floor area Minimum and maximum .75 per unit Landscaping Refer to “Article 9: Landscaping” of the City’s Land Development Regulations. f Galveston ARTICLE 3, District Yard, Lot and Setback Standards Page 3-13 CENTRAL BUSINESS DISTRICT (CBD) Notes: 1. A site plan is required prior to the issuance of a building permit. 2. No side or rear yard required when adjacent to a canal or body of water. 3. Base Flood Elevation: Dry Flood Proofing may be used to protect the space inside the building below the Base Floor Elevation if the ground floor entrance is not above the base flood elevation. Stairs and ramps may be incorporated inside the building envelope to transition to a higher level. In the case that dry flood proofing is not feasible, exterior stairs and ramps or other approaches shall only be permitted. Exterior ramps and stairs when used shall be positioned to minimize the impact and accessibility of the commercial storefront. 4. 5. 6. Fence screening: When a commercial use abuts a residential zone or use, a five-foot (5’) solid concrete or wood material wall shall be installed along common property lines to visually screen the commercial use from the residential use or zone. Alcohol Sales Regulations: Within the CB, a special character area shall be st rd established between 21 and 23 street, approximately 160’ (one-hundred and sixty feet) north and south of the centerline of Postoffice, bars and nightclubs are prohibited land uses. Alcohol sales incidental to operation of a restaurant are permitted. Building setbacks may conflict with Fire Code. Refer to Fire Code to determine final building and fire code setbacks. Minimum Lot Standards Area: Width: Depth: 3,000 square feet 0-feet 0-feet Setbacks Front: Side: Rear: 0-feet 0-feet 0-feet Building Height Maximum: None Parking Residential: Non-Residential: Lodging: Location: Minimum 1 per unit One (1) per 300 square feet of gross floor area Minimum .75 per unit Off/On Site Landscaping Refer to “Article 9: Landscaping” of the City’s Land Development Regulations. City of Galveston 823 Rosenberg Galveston, TX 77550 f Galveston ARTICLE 3, District Yard, Lot and Setback Standards Page 3-14 COMMERCIAL (C) Notes: 1. A site plan is required prior to the issuance of a building permit. 2. No side or rear yard required when adjacent to a body of water or right-of-way. 3. No projection closer than 12 inches to a common property line. Projections include: roof eaves (up to 36”) window sills, belt courses, and other architectural features. 4. Sign, fence, and wall regulations apply. 5. Boat slips, boat docks, shade covers, or decking constructed over water do not require a setback provided the improvement built over water is part of the platted lot. 6. One-family attached dwelling units require a zero-foot (0’) rear yard setback when abutting another one-family attached dwelling. 7. Accessory buildings are permitted in the rear yard. A three foot (3’) rear yard setback required, unless abutting alley or street then no required rear yard setback. Minimum Lot Standards Area: Width: Depth: Setbacks Front: 8. Unlimited height from the east property line of Stewart Beach and eastward. 9. Building setback may conflict with Fire Code. Refer to Fire Code to determine final building and fire code setbacks. CONTINUE TO NEXT PAGE. 0 square feet 40-feet 100-feet Side: Rear: 0 – 10 feet; On Broadway (between eastside of 23rd St. and west side of 19th St. and the 2300 to 2600 block) a 25-ft. to 45-ft. build-to-line is required 5-feet 0-feet; 10-ft if development abuts a residential zone Building Height Maximum: 50-feet, measured from base flood elevation Parking Residential: Non-Residential: Lodging: Parking Location: City of Galveston 823 Rosenberg Galveston, TX 77550 f Galveston ARTICLE 3, District Yard, Lot and Setback Standards Minimum 1.5 per unit Minimum 1 per 300 sq. ft. of gross floor area Minimum .75 per unit Rear of building Landscaping Refer to “Article 9: Landscaping” of the City’s Land Development Regulations. Page 3-15 COMMERCIAL (C) Notes (cont): Commercial District Fence Regulations 10. Maximum height of a fence is eight-feet (8’). Fence must be constructed in a workmanship manner. Horizontal and vertical support posts are inside of the fence area or otherwise hidden from both the neighbor’s and general public’s view. Fences with a shadow-box design shall be considered to hide support posts. No more than two different types of fencing material is permitted. Property owners shall be responsible for the maintenance of the fencing on their property, and for removal of any fence if it becomes unsightly or a menace to public safety, health or welfare. Fences shall be maintained in an upright condition. It shall be the responsibility of the property owner to insure that a fence does not block or obstruct the flow of storm water. Corrosive resistant material required. Broadway Boulevard Design Standards 19th Street to 61st Street and 61st Street to Causeway 11. Cross access easement required. If access provided from Broadway, maximum of two curb cuts, maximum curb cut width is 25’. 12. Vending machines & vending kiosks visible from Broadway Boulevard right-of-way are prohibited. 13. Building Materials: exterior new or renovations shall use stucco, brick, wood, painted or textured concrete, tile, glass block or cast iron. 14. Roof Materials: Spanish roof tiles, standing seam metal, composition shingle (applies if visible from right-of-way). Repair and maintenance work exempt. 15. Vehicle Access: Where alternative access available, access prohibited from Broadway. 16. Fencing Prohibited: Fronting on Broadway. Residential Fencing Maximum Height: 42” solid fence;80” open fence design. Barbed wire and chain link prohibited. 17. Exceptions to fence regulations: A protective barrier of 30” height and located behind a solid landscaped screen. Fences existing on the date this ordinance passed. Parking lots associated with hotel/motel resort developments. Barbed wire and cyclone fences installed prior to the adoption of this ordinance. Seawall Boulevard Design Standards South Jetty east to Condo Rd.; Condo Rd. west to 39th St.; 39 St. West to 61st St.; 61st St. west to Cove View Blvd. 18. Fencing: Prohibited within area between the north right-of-way line of Seawall Boulevard and south façade of building. 19. Residential Fencing Maximum Height: 42” solid fence; 60” open fence design. 20. Vending Machines: attached to permanent structure, meet setbacks, proper ventilation, (i.e. phones, ice machines, water, soft drinks, etc.) 21. Buffering/Screening between commercial/lodging uses and residential zones and uses. A 4’ wide landscaped strip and a 5’ solid all or fence along all common property lines, including rear property lines separated by right-of-way. th 22. f Height Limitation for properties located South of the Seawall, from 10 Street to South Jetty – No 224244. ARTICLE 3, District Yard, Lot and Setback Standards Page 3-16 HISTORIC ZONING DISTRICT (HZD) Notes: The following historical districts (as identified in the historical overlay maps) are subject to the provisions set forth in the zoning designation HZD: o East End Historical District (EEHD) o Silk Stocking Historical District (SSHD) o Lost Bayou Historical District (LBHD) 1. A site plan is required prior to the issuance of a building permit. 2. No projection closer than 12 inches to a common property line. Projections include: roof eaves (up to 36”), window sills, and other architectural features. 3. Sign, fence, and wall regulations apply. 4. Accessory buildings are permitted in the rear yard. A 1 foot rear yard and side yard setbacks are required, unless abutting alley or street then no required rear yard setback. 5. Article 2, Sec 2.311 “Child Facility Residential (Day Care)” shall be permitted only in the Lost Bayou Historical District. 6. Building setback may not conflict with Fire Code. Refer to Fire Code to determine final building setbacks. Minimum Lot Standards Area: Width: Depth: 2,500 square feet 0-feet 0-feet Setbacks Front-Build-to-Line: Side: Rear: 15-feet 1-foot 1-foot Building Height Maximum: CONTINUE TO NEXT PAGE. 50-feet, measured from base flood elevation Parking Residential: Minimum one (1) per unit Bed and Breakfast: One (1) per guest room; two (2) of which may be placed in the street along the front yard Commercial: One (1) per 1,500-sq. ft. of gross floor area Landscaping City of Galveston 823 Rosenberg Galveston, TX 77550 f Galveston ARTICLE 3, District Yard, Lot and Setback Standards Refer to “Article 9: Landscaping” of the City’s Land Development Regulations. Page 3-17 HISTORIC ZONING DISTRICT (HZD) Notes (cont): 7. Commercial land uses in corner stores shall be permitted only at the following addresses: 1801, 1806, 1827, 1828 – AVENUE L 1203, 1327 — BALL / AVENUE H 902, 1004, 1501, 1801, 1804 — BROADWAY / AVENUE J 1202, 1301, 1427, 1527, 1602 — CHURCH / AVENUE F 1327, 1728, 1801, 1802 — MARKET / AVENUE D 902, 927, 1028, 1127, 1201, 1202, 1208 — POST OFFICE / AVENUE E 902, 1728 — SEALY / AVENUE I 1602 — WINNIE / AVENUE G th 924 — 10 STREET th 303, 305 — 16 STREET th 302 — 17 STREET th 1127 — 18 STREET th 710, 1206 — 19 STREET st 1302 — 21 STREET / MOODY th 1124 — 25 STREET / ROSENBERG a. b. 9. Commercial activity as permitted for Historic Zoning District in corner stores shall be limited to the ground floor. Signage for corner stores shall be limited to 20 sf max sign face and 15-ft. max height. Gross Floor Area Limited to 2,500 sq. ft. ARTICLE 3, District Yard, Lot and Setback Standards Page 3-18 LIGHT INDUSTRIAL DISTRICT (LI) Notes: 1. A site plan is required prior to the issuance of a building permit. 2. No side or rear yard required when adjacent to a canal or body of water. 3. Bulk fuel or oil storage shall be located 300feet from any residential land use or commercial district. 4. Building setback may conflict with Fire Code. Refer to Fire Code to determine final building and fire code setbacks. Minimum Lot Standards Area: Width: Depth: 0 square feet 0-feet 0-feet Setbacks Front: Side: Rear: 0-feet 0-feet 0-feet Building Height Maximum: None Parking One (1) space per every four (4) employees Landscaping Refer to “Article 9: Landscaping” of the city’s Land Development Regulations. City of Galveston 823 Rosenberg Galveston, TX 77550 f Galveston ARTICLE 3, District Yard, Lot and Setback Standards Page 3-19 HEAVY INDUSTRIAL (HI) Notes: 1. A site plan is required prior to the issuance of a building permit. 2. No side or rear yard required when adjacent to a canal or body of water. 3. Bulk fuel or oil storage shall be located 300feet from the property line or zoning district boundary of any residential land use or commercial district. 4. Building setbacks may conflict with Fire Code. Refer to Fire Code to determine final building and fire code setbacks. Minimum Lot Standards Area: Width: Depth: 0 square feet 0-feet 0-feet Setbacks Front: Side: Rear: 0-feet 0-feet 0-feet Building Height Maximum: None Parking One (1) space per every four (4) employees Landscaping Refer to “Article 9: Landscaping” of the city’s Land Development Regulations. City of Galveston 823 Rosenberg Galveston, TX 77550 f Galveston ARTICLE 3, District Yard, Lot and Setback Standards Page 3-20