Fluke Infrared Temperature Selection Guide You know and trust Fluke for rugged, reliable and accurate digital multimeters. But did you know you can get the same Fluke quality in thermometers? Today, we offer a complete set of contact and non-contact IR temperature test tools, plus all the probes, accessories and application expertise you need to get the job done. Fluke also backs its tools with one of the top warranties in the industry and the highest rated customer service. With more than two decades of thermometry experience, Fluke knows temperature. 3 steps to choosing the IR model for your needs Step 1 842 °F Determine your temperature 1050 °C 1922 °F 850 °C 1562 °F Symbol key 572 EMS R Reporting EMS 650 °C 1202 °F 566 450 °C 842 °F -150 °C 650 °C EMS 568 574 R R EMS EMS Adjustable emissivity Contact and noncontact in one tool 250 °C 482 °F 561 EMS R 50 °C 122 °F Photo reporting 576 Step 3 EMS Determine key features 62 0 °C 32 °F 0.5 m 5 m 10 m 12 m 1.6 ft 16 ft 33 ft 40 ft -50 °C -58 °F Step 2 Determine your maximum distance to the object electrical panel superheat with probe ducts bearings, gears motor case Top 5 temperature applications Infrared temperature quick reference guide Fluke 62 Mini Compact entry level tool Small enough to fit in your pocket, includes a backlit display and a laser point to assist in sighting your target Fluke 561 Fluke 566 Fluke 568 Rugged tools that provide a total contact and non-contact temperature solution for industrial, HVAC, and electrical professions With an innovative graphical LCD display, a straight-forward user interface and soft-key menus, the Fluke 566 and 568 thermometers make even complex temperature measurements easy. Quickly and simply adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button Intrinsically safe. Use where flammable gases are present Short range troubleshooting work, electrical, HVAC and industrial applications Plant maintenance, HVAC/R, and electromechanical -30 ºC to 500 ºC (-20 ºF to 932 ºF) -40 °C to 550 °C (-40 °F to 1022 °F) -40 ºC to 650 ºC (-40 ºF to 1200 ºF) -40 ºC to 800 ºC (-40 ºF to 1470 ºF) -30 ºC to 760 ºC (-25 ºF to 1400 ºF) Up to 2 m (6 ft) Up to 2 m (6 ft) Up to 4.5 m (15 ft) Up to 7.5 m (25 ft) Up to 7.5 m (25 ft) Optical resolution (Distance:Spot or D:S) 10:1 12:1 30:1 50:1 50:1 Accuracy +/- % of reading 1.5 % 1% 1% Sighting Laser point Laser point Laser point Emissivity Pre-set 0.95 Adjustable (3 settings) Data logging — — 20 data points 99 data points 12 data points Data output — — — USB — — Includes K-type Velcro® thermocouple pipe probe (compatible with all standard mini-connector K-type thermocouples) Recommended uses Temperature range Typical distance to target (spot) Probe Certifications CE, FDA/IEC Laser Caution notice Multiple languages — Alarms — General and electromechanical plant maintenance, transportation, diesel Fluke 68IS* Professional diagnostic tool with FM approval for use in hazardous locations Numerical and material table Includes bead K-type thermocouple compatible with all standard mini-connector K-type thermocouples) Backlight 1 level 1 level Software — — Numerical Includes RTD CE, FM, FDA/IEC Laser Caution notice CE, FDA/IEC Laser Caution notice — Hazardous Locations (Petrochemical, Chemical) Multiple language interface Eng, Spn, Frn, Ger, Por, Chinese — Hi/Lo alarms (audible and visual) Hi/Lo alarms 2 levels 1 level — FlukeView® Forms — *Fluke 68 IS Intrinsically Safe, Class I, Division 1, Groups A, B, C, D Class I, Zone 0, Aex ia IIC, T4 at 50 °C when used with 9 V alkaline battery. Factory Mutual Research is an approving organization in the United States and, while businesses in many countries accept its approvals, FM approval may not be sufficient in some locales. Acceptance of FM approval will be dependent on the particular company, its location, and local regulation. The information in this document is a summary of specifications for the products listed. Please check the product data sheet for a complete list of specifications. Fluke 572 Fluke 572CF Fluke 574 Fluke 574CF The precision device for vital analysis The close focus precision device for vital analysis The precision device for vital analysis The close focus precision device for vital analysis Precision optics feature unique coaxial laser sighting that indicates the diameter of the target area. Same features as Fluke 572 plus a special feature to measure smaller target objects—minimum spot size 6 mm (0.24 in) Precision optics feature unique coaxial laser sighting that indicates the diameter of the target area. Same features as Fluke 574 plus a special feature to measure smaller target objects—minimum spot size 6 mm (0.24 in) Predictive and preventive maintenance, electrical, process monitoring, heavy equipment, quality assurance programs Predictive and preventive maintenance, ideal for small objects, such as electrical components Predictive and preventive maintenance, electrical, process monitoring, heavy equipment, quality assurance programs -30 ºC to 900 ºC (-25 ºF to 1600 ºF) Fluke 574NI** Fluke 576 Fluke 576CF Precision tool with FM Photographic infrared approval for use in thermometer hazardous locations Same features as Fluke 574 plus non-incendive.** Predictive and prePredictive and preventive maintenance, ventive maintenance ideal for small objects, in potentially hazardsuch as electrical ous locations, such components as petrochemical and chemical -30 ºC to 900 ºC (-25 ºF to 1600 ºF) Photographic infrared thermometer with close focus Photographic infrared thermometer documents temperature and images. Same features as Fluke 576 plus a special feature to measure smaller target objects—minimum spot size 6 mm (0.24 in) Predictive and preventive maintenance, electrical, process monitoring, heavy equipment, quality assurance programs where documentation is needed Same as 576 plus a close focus feature makes it especially ideal for small objects such as electrical components -30 ºC to 900 ºC (-25 ºF to 1600 ºF) Up to 10.5 m (35 ft) 300 mm (11.4 in) Up to 10.5 m (35 ft) 300 mm (11.4 in) Up to 10.5 m (35 ft) Up to 10.5 m (35 ft) 300 mm (11.4 in) 60:1 50:1 60:1 50:1 60:1 60:1 50:1 ± 0.75 % of reading or ± 0.75 ºC (± 1.5 ºF) whichever is greater ± 0.75 % of reading or ± 0.75 ºC (± 1.5 ºF) whichever is greater ± 0.75 % of reading or ± 0.75 ºC (± 1.5 ºF) whichever is greater True Dimension™ Sighting True Dimension™ Sighting True Dimension™ Sighting Numerical Numerical and material table Numerical and material table — 100 data points 100 data points + images — RS-232 USB — Includes K-type Thermocouple Includes K-type Thermocouple CE, FDA/IEC Laser Caution notice CE, FDA/IEC Laser Caution notice CE, FM, FDA/IEC Laser Caution notice CE, FDA/IEC Laser Caution notice — — — Hi alarm (audible and visible) Hi/Lo alarms (audible and visible) Hi/Lo alarms (audible and visible) 1 level 1 level 1 level — IRGraph software IRGraph software **Fluke 574NI Non-incendive, Class I, Division 2, Group A, B, C, D; Class I, Zone 2IIC; T4 Ta=50 ºC when used with 1.5 V alkaline batteries. Factory Mutual Research is an approving organization in the United States and, while businesses in many countries accept its approvals, FM approval may not be sufficient in some locales. Acceptance of FM approval will be dependent on the particular company, its location, and local regulations. The information in this document is a summary of specifications for the products listed. Please check the product data sheet for a complete list of specifications. Fluke 51 Series II Fluke 52 Series II Field unit with laboratory accuracy Fluke 53 Series II Fluke 54 Series II Field unit with laboratory accuracy and certification High accuracy contact temperature measurement with fast response time to capture measurements and show you trends. Datalogging capabilities for analysis and reports using FlukeView® Forms (Fluke 53/54 only). Product can be certified to meet laboratory requirements (Fluke 53/54 only). Contact temperature quick reference guide Recommended uses Use for quality control to ensure product is within manufacturing tolerances, calibration to monitor product conformance and manufacturing processes, HVAC applications to monitor air temperature and equipment, and food processing and preparation to monitor safe and unsafe temperature levels. Biomedical and medical lab applications where temperature measurement is critical and chemical and pharmaceutical industry applications where precision and certification is required (Fluke 53/54 only). Thermocouple types K, J, T, E K, J, T, E, N, R, S Temperature range J-type: -210 ºC to 1200 ºC (-346 ºF to 2192 ºF); K-type: -200 ºC to 1372 ºC (-328 ºF to 2501 ºF); T-type: -250 ºC to 400 ºC (-418 ºF to 752 ºF); E-type: -150 ºC to 1000 ºC (-238 ºF to 1832 ºF) J-type: -210 ºC to 1200 ºC (-346 ºF to 2192 ºF); K-type: -200 ºC to 1372 ºC (-328 ºF to 2501 ºF); T-type: -250 ºC to 400 ºC (-418 ºF to 752 ºF); E-type: -150 ºC to 1000 ºC (-238 ºF to 1832 ºF) N-type: –200 ºC to 1300 ºC (–392 ºF to 2373 ºF); R and S-Type: 0 ºC to 1767 ºC (32 ºF to 3212 ºF) Number of inputs Single MIN/MAX/AVG recording with time stamp Differential (T1-T2) readout Datalogging up to 500 points Time stamp Temperature scale Applicable standards Dual Yes — Dual Yes Yes — Yes — Yes Relative time Time of day ITS-90 ITS-90 NIST-175 NIST-175 Display resolution Battery life (typical) Single 0.1 °C/°F/K < 1000 ° 1 °C/°F/K ≥ 1000 ° 1000 hours 1000 hours Yes Yes IR data port for PC interface — Yes FlukeView® Forms — Yes Dual display w/backlight Temperature accessories matched to your job Expand the functionality of your Fluke thermometers with the right Fluke temperature probes. Our full line of probe accessories support your application with the same rugged reliability of all Fluke tools. Bead Bead Immersion Surface Air Piercing General Purpose Industrial Surface Pipe Clamp HVAC 80BK 80PK-1 80PJ-1 80PK-22 80PK-3A 80PK-24 80PK-25 80PT-25 80PK-26 80PK-27 80PK-8 80PK-9 80PJ-9 Lowest temp -40 °C, (-40 °F) 0 °C (32 °F) -40 °C (-40 °F) 816 °C (1500 °F) 350 °C (662 °F) 816 °C (1500 °F) 600 °C (1112 °F) 149 °C (300 °F) 260 °C (500 °F) 304 Stainless Steel K type sensor with pvc body 304 Stainless Steel for pipes from 6.4 mm (.25 in) to 34.9 mm (1.375 in) 15.25 cm (6 in) Highest temp 260 °C (500 °F) Probe material K-type wire with teflon insulation Inconel 600 K type sensor with teflon body Inconel 316 Stainless Steel 1 m lead wire 21.27 cm (8.375 in) 9.525 cm (3.75 in) 21.59 cm (8.5 in) 10.16 cm (4 in) Probe length Cable length Connection 1 m (39 in) Thermocouple types 20.32 cm (8 in) 1 m (39 in) Molded thermocouple plug No Yes Ideal for initial troubleshooting. Can be secured in place with a magnet. For use in liquids or in gels. K 21.57 cm (8.5 in) 1.3 m (4 ft) Standard banana jack SureGrip handle Key feature 1090 °C (1994 °F) 260 °C (500 °F) K Type: -40 °C -40 °C (-40 °F) (-40 °F) T Type: -40 °C (-40 °F) -127 °C (-196 °F) -29 °C (-20 °F) -196 °C (-321 °F) K, J No Yes Exposed junc- Perforated baffle Probe material tion for direct for air and safe for use in contact with non-caustic gas foods. Sharp tip flat or slightly measurements pierces solid convex surfaces. surfaces.. K No Use for general purpose air or surface measurements Low conductivity stainless steel minimizes thermal shunting. Extra rugged. K, T Clamps securely to pipe. Measurements are repeatable to 0.56 °C (1 °F). K Sharp tip pierces pipe insulation, flat surface makes good contact with surface. K, J Typical use General purpose • HVAC • • • • • • • • • Food service Industrial • • Residential • • Commercial • • • • • • • • • • • • • • • • • • • • • • • • • • • Use an 80AK adapter with meters that include temperature function such as the 16, 78, 83V, 87V, 88V, 179, 187, 189, 287, and 289 The 80TK enables your meter to read temperature using mV For the Fluke Thermometer, 51, 52, 53, and 54 III, no adapter is necessary for thermocouple types K, J, T and E Fluke.Keeping your world up and running.® Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2007 Fluke Corporation. The information in this document is a summary of specifications for the products listed. Please check the product data sheet for a complete list of specifications. Specifications subject to change without notice. Printed in U.S.A. 10/2007 2556886 H-EN-N Rev C