LI9Y
4X2X0.25
LI9Y C11Y 2X1X1.0 OG
Design
Wire LI9Y 1X1.0/1.85
Stranded bare copper wire 56 X 0.15 (18 AWG)
Insulation of Polypropylene (PP)
ø 1.33 mm (0,052 in dia)
ø 1.85 mm (0,073 in dia)
Pair LI9Y 1X2X0.25/1.15
Wire
Stranded bare copper wire 32 X 0.1 (24 AWG)
Insulation of Polypropylene (PP)
ø 0.69 mm (0,027 in dia)
ø 1.15 mm (0.045 in dia)
2 wires twisted to a pair
Core:
4 pairs LI9Y 1X2X0.25
BK/RD-GY/PK-BN/GN-BU/VT
2 wires LI9Y 1X1.0/1.85 WH-BN
Sequence of colors: BK/RD-GY/PK-BN/GN-BU/VT-WH-BN
+ fillers
Plastic tape, overlapped
Stranded tinned copper drain wire (24 AWG) 0.24 mm²
Shield braiding of tinned copper wires
Coverage about 85%
Plastic tape, overlapped
ø 6.8 mm (0,268 in dia)
Jacket:
Polyurethane (PUR) OG
ø (8.7 ±0.3) mm (0,343 ±0,012 in dia)
Printing: LEONI L * FIELDLINK MC TRAILING * c us AWM 20233 AWM I/II A/B 80 °C 300V FT1
4x2x0.25 + 2x1.0 "internal lot number"
LEONI Special Cables GmbH
Date of issue : 13.10.2008
Phone +49 (0)4491-292-292
Fax +49 (0)4491-292-169
Technical modification reserved
Internet www.leoni-special- cables.com
Creator : LSC E / TURAN
Number : L45551-W69-K18-EN
Up-dating : 15.05.2014
Supersedes : 13.11.2012
Name: Langemeyer
E: 13.10.2008 M: 13.11.2012
Page 1 / 2
LEONI Special Cables GmbH
Technisches Datenblatt - Technical Data Sheet – Technisches Datenblatt – Technical Data Sheet – Technisches Datenblatt
Electrical data at 20°C
Conductor resistance (24AWG)
Conductor resistance (18AWG)
Insulation resistance
Operating voltage
Test voltage (wire/wire/screen rms 50Hz 1min)
Frequency (MHz)
Weitergabe an Dritte nur mit Genehmigung der LEONI Special Cables GmbH - Alle Rechte vorbehalten Transfer to third party only by authority of LEONI Special Cables GmbH
Formular: W1-WW-PT-TDBL2-A-20  DV-Werk1 2000
Shield transfer impedance
(IEC 1196-1) (mOhm/m) ≤
75
20
200
300
1500
≤
≤
≥
≤
0.01
0.5
1
2
4
10
30
20
20
20
20
20
50
150
Ohm/km
Ohm/km
MOhm*km
V
V
Mechanical and thermal characteristics
Conductor/Screen material acc. to DIN EN 13602 Cu-ETP-A...-B
Insulating material acc. to DIN EN 50290-2-25, compound type full PP (HD 624.5)
Jacket material acc. F45052-F5100 (similar to DIN VDE 0282) (Nonsticking material)
Oil resistant acc. to VDE 0282 Part 10 (HD 22.10 S1)
Flame retardant acc. to IEC 60332-1-2
UL-Style 20233 (80°C/300V)
CSA C22.2 No. 210 I/II A/B FT1
Trailing cable for the following requirements
- bendings
10 million
- acceleration
20 m/s²
- horizontal speed
300 m/min
- minimum bending radius
7.5 x outer diameter
- minimum static radius
4 x outer diameter
- torque angle
≤ ± 30°/ m
Other characteristics:
Halogen-free acc. to IEC 60754-1, Silicone-free, FCKW-free
RoHS compliant (Directive 2011/65/EC)
Temperature range:
- Stock temperature
- Operating temperature
- Short-time (≤ 1 sec)
-50 °C (-58 °F) up to 80 °C (176 °F)
-20°C (-4 °F) up to 60°C (140 °F)
150°C (305°F)
Max. pulling force (dynamic)
Max. pulling force (static)
Weight about
20 N/mm²
50 N/mm²
103 kg/km (69 lb/1000ft)
Designation of order:
L45551-W69-K18
215476
LI9Y
4X2X0.25
LI9Y C11Y 2X1X1.0 OG
2000 m (6562 ft) on non-returnable reel
LEONI Special Cables GmbH
Date of issue : 13.10.2008
Phone +49 (0)4491-292-292
Fax +49 (0)4491-292-169
Technical modification reserved
Internet www.leoni-special- cables.com
Creator : LSC E / TURAN
Number : L45551-W69-K18-EN
Up-dating : 15.05.2014
Supersedes : 13.11.2012
Name: Langemeyer
E: 13.10.2008 M: 13.11.2012
Page 2 / 2