SmartHome Alarm series Wirefree Yale ENA-PIR Passive infrared motion detector 8 4 2 3 7 5 1 6 9 Features: 1. Test/Learn Button To enter Test mode: Press once in Standby mode. The LED will light up for two seconds whenever a movement is detected. 2. 3. 4. 5. 6. 7. 8. Red LED Indicator Knockouts for Wall / Corner Mounting Supervision Enable / Disable Jumper Movement High/Low Sensitivity jumper Tamper Switch with spring 3x 1.5V AA Alkaline Battery Tilt Switch (protect against unauthorized EIR removal, sabotage, or loose installation) 9. Top & Bottom Cover securing screw hole Supervision Enable/Disable Jumper After installation, the PIR will automatically transmit Supervisory signals periodically to the Control Panel at random intervals of less than 20 minutes. If the Control Panel has not received the signal from the PIR for the preset period of time, the Control Panel will indicate on its display that the particular PIR is experiencing an out-of-signal problem. Jumper On= Supervision Disabled Jumper Off= Supervision Enabled (Default) Movement High/Low Sensitivity Jumper Jumper On= Increase PIR sensitivity to movement Jumper Off= Decrease sensitivity (Factory Default) Pack content: 1 x PIR 4 x Screws 4 x Wall Plugs Programming Step 1: Remove the PIR battery insulator on the back. It will take 30 seconds for the PIR to initalise (with LED flashing). To allow calibration, stay away from the detection lens during this period. Step 2: Login to the engineer menu on the control panel. Select “Zone Settings” → “Zone Config.” → “Add Zone” on the menu. Press OK and the LCD of the Control Panel will display “*Push button on* Device to add”. Step 3: Press PIR’s Learn button. Step 4: Then if the Control Panel detects a signal transmitted from PIR, the Control Panel will display “Detected (OK?) PIR sensor”. Press OK to confirm the learning. Step 5: Refer to the operation manual (section “Add Zone”) of your Control Panel to complete the learn-in parameter setup. view. • Between 1.9 ~ 2.0 M above ground for best performance. • In a corner to give the widest view. • Where its field of view will not be obstructed e.g. by curtains, ornaments etc. Limitations • Do not position a PIR to look directly at a door protected by a Door Contact. This may cause the Door Contact and the PIR to transmit at the same time and cancel each other out. • Do not expose PIR to direct sunlight. • Avoid installing the PIR in areas where there are rapid change of temperature, i.e. air conditioner, heaters, etc. • Avoid large obstacles in the detection area. • Not pointing directly at sources of heat e.g. fires or boilers, and not above radiators. • Avoid moving objects in the detection area i.e. curtain, wall hanging etc. Step 6: To find the best installation location for the PIR, you will need to make a “Walk Test”. Press the “Return” button and go back to the root selection. Select the “Testing” Menu, then select the “Walk Test” option. Step 7: Hold the PIR in the desired location and press the test/learn button. The RSSI signal strength value will be displayed on the control panel, varied from 0 ~ 9 (9 indicates the best signal strength performance). It is suitable for installation if the RSSI value is 5 or greater. Device is now ready for mounting. Mounting The PIR is suitable for surface or corner mounting. There are knockout holes in the base cover to allow fixing. Using the holes as a template to drill mounting points on the wall. Insert wall plugs and fix the base onto the wall. Put the front cover on the PIR to complete the mounting process. It is recommended to install the PIR in the following locations: • In a position such that an intruder would normally move “across” the PIR’s field of 2M 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Operation Sleep Timer The PIR features an automatic “sleep time” of approximately one minute for power conservation. After transmitting a detected movement, the PIR will not retransmit for one minute. Any further movement detected within this one-minute sleep period will extend the sleep time by another minute. Disable the sleep timer temporarily by entering the test mode. See Test Mode section. LED indicator Off Normal operation LED flash (2 sec) - Detects motion during Low battery, Tamper activated or Test mode. - Spring/Tilt tamper switch is activated. Test Mode Press Test button/LED once to enter test mode. Under test mode, the sleep timer is disabled and the LED lights up whenever movement is detected. The device will auto exit test mode after 3 minutes. Changing Batteries The 3 x 1.5V AA size alkaline batteries have a battery life of approximately three years (based on 20 activations per day). When the low battery condition is shown, the device should have enough power to operate for one month. Step 1: Login to the engineer menu on the control panel. Step 2: Dismount the PIR and remove the batteries. Press Test button for ten times. Step 3: Insert 3 x new 1.5V AA alkaline batteries. Step 4: Replace the cover and mount the sensor. Step 5: Exit the engineer menu and return to standby on the control panel. Specification Tilt Switches/Tamper spring With the PIR placed in an upright position: Environmental conditions: -10c to 40c , relative humidity 85% noncondensing. Indoor use only Radio 868.35MHz FM • Turning left and right Tamper Activate when Turning clockwise more than 45 degree Turning anti-clockwise more than 135 degree. • Tilting Up and down Tamper Activate when Turning down (lens pointing to the floor) more than 110 degree Turning up (lens pointing to the ceiling) more than 80 degree. By turning the PIR the other way (back to the original upright position) will cause it to send a “tamper restore” signal back to the control panel. Opening the unit will also trigger tamper alarm via the tamper spring Battery: 3x 1.5V AA Alkaline Dimension: 92.4mm x 66.5mm x 60mm Standard : EN300-220-1 EN301489-1,3 EN60950 PD6662:2010 Grade 2 Class 2 2 Year Instruction Statement: This product is guaranteed for consumers against faulty workmanship, materials and function for a period of 2 years from the date of purchase providing the full installation and maintenance instructions are followed. Please keep your proof of purchase safe, this must be submitted when making a claim under this guarantee. Please note that it is a condition of this guarantee that your Yale product: • • • Has been correctly installed and maintained in accordance with the Yale installation and maintenance instructions provided to you at the time of purchase. Has not been modified or damaged in any way. Has not been subjected to unauthorized repairs. Yale are responsible under this guarantee for repairing the product or replacing the product as we deem necessary. If there is fault with the product, please contact Customer Services on 01902 364647, who will give you the name of an expert and confirm what you need to do to make a claim under this guarantee. Please do not carry out any repairs without our authority or by using an unauthorised expert. Any repairs or other works carried out without our authorization or by using an unauthorized expert will not be covered under this guarantee. E1 03/11 This guarantee is non transferrable and applies to products purchased in the United Kingdom only. This guarantee does not apply to normal wear and tear. This does not affect your statutory rights. A full copy of the product instructions are available upon request or by visiting our website www.yale. co.uk. RoHS