Wirefree Yale ENA-PIR - Free Instruction Manuals

advertisement
SmartHome Alarm series
Wirefree Yale ENA-PIR
Passive infrared motion
detector
8
4
2
3
7
5
1
6
9
Features:
1. Test/Learn Button
To enter Test mode: Press once in Standby mode. The LED will light up for two seconds whenever a movement is detected.
2. 3. 4. 5. 6. 7. 8. Red LED Indicator
Knockouts for Wall / Corner Mounting
Supervision Enable / Disable Jumper
Movement High/Low Sensitivity jumper
Tamper Switch with spring
3x 1.5V AA Alkaline Battery
Tilt Switch (protect against unauthorized EIR removal, sabotage, or loose installation)
9. Top & Bottom Cover securing screw hole
Supervision Enable/Disable Jumper
After installation, the PIR will automatically transmit
Supervisory signals periodically to the Control Panel
at random intervals of less than 20 minutes. If the
Control Panel has not received the signal from the
PIR for the preset period of time, the Control Panel
will indicate on its display that the particular PIR is
experiencing an out-of-signal problem.
Jumper On= Supervision Disabled
Jumper Off= Supervision Enabled (Default)
Movement High/Low Sensitivity Jumper
Jumper On= Increase PIR sensitivity to movement
Jumper Off= Decrease sensitivity (Factory Default)
Pack content:
1 x PIR
4 x Screws
4 x Wall Plugs
Programming
Step 1: Remove the PIR battery insulator
on the back. It will take 30 seconds for the
PIR to initalise (with LED flashing). To allow
calibration, stay away from the detection lens
during this period.
Step 2: Login to the engineer menu on the
control panel. Select “Zone Settings” → “Zone
Config.” → “Add Zone” on the menu. Press OK
and the LCD of the Control Panel will display
“*Push button on* Device to add”.
Step 3: Press PIR’s Learn button.
Step 4: Then if the Control Panel detects a
signal transmitted from PIR, the Control Panel
will display
“Detected (OK?) PIR sensor”. Press OK to
confirm the learning.
Step 5: Refer to the operation manual (section
“Add Zone”) of your Control Panel to complete
the learn-in parameter setup.
view.
• Between 1.9 ~ 2.0 M above ground for best performance.
• In a corner to give the widest view.
• Where its field of view will not be obstructed e.g. by curtains, ornaments etc.
Limitations
• Do not position a PIR to look directly at a door protected by a Door Contact. This may cause the Door Contact and the PIR to transmit at the same time and cancel each other out.
• Do not expose PIR to direct sunlight.
• Avoid installing the PIR in areas where there are rapid change of temperature, i.e. air conditioner, heaters, etc.
• Avoid large obstacles in the detection area.
• Not pointing directly at sources of heat e.g. fires or boilers, and not above radiators.
• Avoid moving objects in the detection area i.e. curtain, wall hanging etc.
Step 6: To find the best installation location for
the PIR, you will need to make a “Walk Test”.
Press the “Return” button and go back to the
root selection. Select the “Testing” Menu, then
select the “Walk Test” option.
Step 7: Hold the PIR in the desired location
and press the test/learn button. The RSSI signal
strength value will be displayed on the control
panel, varied from 0 ~ 9 (9 indicates the best
signal strength performance). It is suitable for
installation if the RSSI value is 5 or greater.
Device is now ready for mounting.
Mounting
The PIR is suitable for surface or corner
mounting. There are knockout holes in the
base cover to allow fixing. Using the holes as a
template to drill mounting points on the wall.
Insert wall plugs and fix the base onto the wall.
Put the front cover on the PIR to complete the
mounting process.
It is recommended to install the PIR in the
following locations:
• In a position such that an intruder would normally move “across” the PIR’s field of 2M
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Operation
Sleep Timer
The PIR features an automatic “sleep time” of
approximately one minute for power conservation.
After transmitting a detected movement, the PIR
will not retransmit for one minute. Any further
movement detected within this one-minute sleep
period will extend the sleep time by another
minute. Disable the sleep timer temporarily by
entering the test mode. See Test Mode section.
LED indicator
Off
Normal operation
LED flash
(2 sec)
- Detects motion during Low
battery, Tamper activated or Test
mode.
- Spring/Tilt tamper switch is
activated.
Test Mode
Press Test button/LED once to enter test mode.
Under test mode, the sleep timer is disabled
and the LED lights up whenever movement is
detected. The device will auto exit test mode after
3 minutes.
Changing Batteries
The 3 x 1.5V AA size alkaline batteries have a
battery life of approximately three years (based
on 20 activations per day). When the low battery
condition is shown, the device should have
enough power to operate for one month.
Step 1: Login to the engineer menu on the
control panel.
Step 2: Dismount the PIR and remove the
batteries. Press Test button for ten times.
Step 3: Insert 3 x new 1.5V AA alkaline batteries.
Step 4: Replace the cover and mount the sensor.
Step 5: Exit the engineer menu and return to standby on the control panel.
Specification
Tilt Switches/Tamper spring
With the PIR placed in an upright position:
Environmental conditions:
-10c to 40c , relative humidity 85% noncondensing. Indoor use only
Radio
868.35MHz FM
• Turning left and right
Tamper Activate when
Turning clockwise more than 45 degree
Turning anti-clockwise more than 135 degree.
• Tilting Up and down
Tamper Activate when
Turning down (lens pointing to the floor) more
than 110 degree
Turning up (lens pointing to the ceiling) more
than 80 degree.
By turning the PIR the other way (back to the
original upright position) will cause it to send a
“tamper restore” signal back to the control panel.
Opening the unit will also trigger tamper alarm via
the tamper spring
Battery:
3x 1.5V AA Alkaline
Dimension:
92.4mm x 66.5mm x 60mm
Standard :
EN300-220-1
EN301489-1,3
EN60950
PD6662:2010 Grade 2 Class 2
2 Year Instruction Statement:
This product is guaranteed for consumers
against faulty workmanship, materials
and function for a period of 2 years from
the date of purchase providing the full
installation and maintenance instructions
are followed. Please keep your proof of
purchase safe, this must be submitted when
making a claim under this guarantee.
Please note that it is a condition of this
guarantee that your Yale product:
•
•
•
Has been correctly installed and maintained in accordance with the Yale installation and maintenance instructions provided to you at the time of purchase.
Has not been modified or damaged in any way.
Has not been subjected to unauthorized repairs.
Yale are responsible under this guarantee
for repairing the product or replacing the
product as we deem necessary. If there
is fault with the product, please contact
Customer Services on 01902 364647, who
will give you the name of an expert and
confirm what you need to do to make a
claim under this guarantee.
Please do not carry out any repairs without
our authority or by using an unauthorised
expert. Any repairs or other works carried
out without our authorization or by using
an unauthorized expert will not be covered
under this guarantee.
E1 03/11
This guarantee is non transferrable and
applies to products purchased in the United
Kingdom only. This guarantee does not
apply to normal wear and tear. This does not
affect your statutory rights. A full copy of
the product instructions are available upon
request or by visiting our website www.yale.
co.uk.