UL/CSA DUAL LISTED LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT Construction: Constructed of continuously interlocked steel strip that forms a metal core which is jacketed with sunlight resistant thermoplastic material Product Index Price Sheet Type UL Liquid-Tight Flexible Metallic Conduit Part Number Standard Packaging U037501001 U037506002 U050001001 U050005002 U050010002 U075001001 U075005002 U075010002 U100001001 U100004002 U125000501 U125002502 U150000501 U150001502 U200000501 U200001002 U250000251 U250001002 U300000251 U300001002 U350000251 U400000251 100’ coil 600’ reel 100’ coil 500’ reel 1000’ reel 100’ coil 500’ reel 1000’ reel 100’ coil 400’ reel 50’ coil 250’ reel 50’ coil 150’ reel 50’ coil 100’ reel 25’ coil 100’ reel 25’ coil 100’ reel 25’ coil 25’ coil Inside Diameter Min Max Outside Diameter Min Max 3/ 8” .484 .504 .690 .710 4 27 1/2” .622 .642 .820 .840 6.5 31 3/ 4” .820 .840 1.030 1.050 8.5 40 1” 1.041 1.066 1.290 1.315 13 76 1-1/ 4” 1.380 1.410 1.630 1.660 16 102 1-1/ 2” 1.575 1.600 1.865 1.900 18 103 2” 2.020 2.045 2.340 2.375 22.25 145 2-1/ 2” 2.480 2.505 2.840 2.875 29.25 197 3” 3.070 3.100 3.460 3.500 35 265 3-1/ 2” 4” 3.500 4.000 3.540 4.040 3.960 4.460 4.000 4.500 40 48 300 333 Trade Size Industry Standards and References: • NEC Article 350 - "Liquid-tight Flexible Metal Conduit" • Permitted for equipment grounding in sizes 3/8" - 1-1/4" in lengths not exceeding 6 feet in accordance with NEC 250-118(7) • UL Listed per UL Standard for Safety 360, File #E78759 • Approved by Canadian Standards Association, Certification #L55384-1 Online Certifications & Tools: • Online Listing Certifications Directories: • UL Online Certifications Directory (www.ul.com) • CSA Online Certifications Directory (www.csa.ca) • Online Product Guide Information: • UL Product Guide Info - Flexible Metal Conduit, Liquid-Tight (DXHR) • CSA Product Information - ConduitFlexible Metal, Liquid-Tight (1812-03) MADE IN USA catalog #2003/rev1 UL ® Packaging: • Standard coils and reels per chart • Bar coded • For lengths not listed, please consult factory Apprx. Apprx. Inside Bend Weight Diameter (per 100 ft.) • Hazardous Locations – where necessary for flexible connections within hazardous locations in accordance with the following: •Class 1, Div. 2 - NEC 501.4(B)(2) & 501.16(B) •Class 2, Div. 1 - NEC 502.4(A)(1)(e) & 502.16(B) •Class 2, Div. 2 - NEC 502.4(B)(2) •Class 3, Div. 1 – NEC 503.3(A)(2) & 503.16(B) •Class 3, Div. 2 – NEC 503.3(B) • Floating Building in accordance with NEC 553.7 • Boatyards & Marinas in accordance with NEC 555.13 • Cranes & Hoists in accordance with NEC 610.11 • For Elevator, Dumbwaiters, Escalators, Moving Walks, Wheel Chair Lifts & Stairway Chair Lifts in accordance with NEC 620.21 (where expressly permitted) • Under raised floors for information technology equipment conductors and cables in accordance with NEC 645.5(D) & 645.5(D)(2) • For flexible connections to swimming pool, spa, and hot tub motors in accordance with NEC 680.21(A)(3) & 680.42(A)(1) • Metal Core: The metal core is constructed of a hot-dipped galvanized, interlocking steel strip with a heavy coating of zinc, helically formed into a metal core – trade sizes 3/8" to 1-1/4" contain an integral copper bonding conductor located within the interlocking strip • Thermoplastic Jacket: A gray thermoplastic jacket is extruded over the metal core which provides protection from liquids, oil, certain chemicals, temperature, weather and sunlight – other jacket colors are available Features & Ratings: • A protective thermoplastic outer jacket which seals out water, liquids, abrasives, alcohol, coolants, corrosive fumes and gases, dirt, grease, mineral acids, nonconcentrated fixed alkalines, petroleum oils, salt air and spray, water and weather • Smooth metal interior for easy wiring pulling • UV sunlight resistant jacket • Accepts standard metallic liquid-tight fittings • Rated for temperature range of -30°C to 80°C, 60°C Oil (-22°F to +176°F, 140°F Oil) • Rated for direct burial applications • All conduit available with black jacket – add suffix B to part number (example: U050001001B) Markings: • Printed jacket identifying Alflex, product name, size, UL, CSA, and product ratings General Applications: • For the installation and protection of electrical conductors in circuits of 600 volts nominal, or less • Motor circuits – for conductors of motor feeders, branch and control circuits • Where the conditions of installation, operation maintenance require flexibility or protection from liquids, vapors, solids or weather • Used in industrial and commercial applications for conveyors, blowers, cranes, air conditioners, machine tooling and lubrication equipment • Applications requiring movement, crossover connections, or tight bends • Approved for exposed or concealed locations • Rated for direct burial applications – conduit rated as suitable for direct burial applications are also suitable for concrete encasement Specific Applications • Electric signs and outline lighting supply and secondary-circuit conductors in accordance with NEC 600.7, 600.31 (1000 Volts or less) & 600.32 (over 1000 volts) 13