1-39 Class I, Div. 2 Class II, Div. 1 and 2 Class III Div. 1 and 2 NEC 501-4(b), 502-4(a)(2), 503-3(a) Applications • Provides a dependable connection for liquidtight flexible metal conduit. Seals out oil, water, dust, dirt and fumes. Features • ST Series has plain throat; STB Series has insulated throat to protect against wire damage. • Unique long ferrule with more pronounced threads provides over four times UL pull-out requirements. • Ferrule also provides maximum surface contact for better sealing and a continuous, permanent, positive metalto-metal ground. • Liquidtight/raintight/oiltight. • Suitable for wet locations. • Full, machined tapered threads (NPT). • Compact design with small turning radius. Standard Materials • 3/8" to 1" (straight): steel. • 1-1/4" to 6" (straight) and 3/8" to 4" (45° and 90°): malleable iron. • Ferrule: (3/8" to 1") steel; (1-1/4" to 6") aluminum. Standard Finishes • Steel-zinc electroplate. • Malleable iron-zinc electroplate, dichromate and aluminum polymer enamel. Size Range: • 3/8" thru 6" conduit size (straight) • 3/8" thru 4" conduit size (45° and 90°) Compliances • UL Standard 5146. • CSA Standard C22.2 No. 65178. • Suitable for hazardous locations Class I, Div. 2 Class II, Div. 1 and 2 Class III, Div. 1 and 2 NEC 501-4(b), 502-4(a)(2), 503-3(a) Effective October, 1993 Copyright 1993 Printed in U.S.A. Liquidtight "ST" and "STB" Connectors for Flexible Metal Conduit ST Series with plain throat; STB Series with insulated throat. ST Connectors Straight Catalog Number ST-38 ST-50 ST-75 ST-100 ST-125 ST-150 ST-200 ST-250 ST-300 ST-350 ST-400 ST-500 ST-600 90° 45° Catalog Size Size Number 3/8 flex, 1/2 hub ST-4538 1/2 ST-4550 3/4 ST-4575 1-1/4 ST-45100 1-1/2 ST-45125 2 ST-45150 2-1/2 ST-45200 3 ST-45250 3-1/2 ST-45300 4 ST-45400 — 5 — 6 — 3/8 flex, 1/2 hub 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 — — — Catalog Number ST-9038 ST-9050 ST-9075 ST-90100 ST-90125 ST-90150 ST-90200 ST-90250 ST-90300 ST-90400 — — — Size 3/8 flex, 1/2 hub 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 — — — STB Connectors Straight Catalog Number 45° 90° Catalog Size STB-38 3/8 flex. 1/2 hub STB-50 1/2 STB-75 3/4 STB-100 1 STB-125 1-1/4 STB-150 1-1/2 STB-200 2 STB-250 2-1/2 STB-300 3 STB-350 3-1/2 STB-400 4 STB-500 5 STB-600 6 Number Catalog Size STB-4538 STB-4550 STB-4575 STB-45100 STB-45125 STB-45150 STB-45200 STB-45250 STB-45300 STB-45400 3/8 flex, 1/2 hub 1/2 3/4 1 — — — — — — 1-1/4 1-1/2 2 2-1/2 3 4 Number Size STB-9038 STB-9050 STB-9075 STB-90100 STB-90125 STB-90150 STB-90200 STB-90250 STB-90300 STB-90400 3/8 flex, 1/2 hub — — — — — — 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 1701 West Wellington Avenue Chicago, Illinois 60657 PAGE 39 ST Liquidtight Flexible Metal Conduit Connectors and Hubs Metallic Connectors Held Tight For Over 4 Times The UL Pull-out Requirement! Seal Out Oil, Water, Dirt, Dust and Fumes in Applications For: Space saving straight and 90° "STN" Series (Page 9) with an insulated throat wedge adapter designed to form a tight seal in knockouts provides maximum wiring room. Straight "STN" sizes from 3/8" to 4" and 90° 3 "STN" sizes from /a" to 1". • Food Processors • Beverage Plants • Chemical Plants • Dairies • Machine Shops • Plastic Fabricators • Petroleum Machinery • Gantry Cranes ... And Many Others a Straight "ST" and "STB" (Pages 3,4) Series with grounding ferrule. "STB" series has insulated throat. "ST" and "STB" sizes 3/a" to 6". 45° "ST" and "STB" Series (Pages 3,4) make some of the most difficult wiring jobs easier. Sizes 3/a" to 4". 90° "ST" and "STB" Series (Pages 3, 4) for use where there isn't room to connect straight off an encloser, which saves on conduit and conductors. Sizes 3/e" to 4". Refer to Pricing Index for Prices. Page 2 Effective November, 1993 90° "STL" Pulling Elbows (Page 10) have one end for connecting liquidtight flexible conduit. The other end has a close, removable male nipple to make female. Sizes 1/2", 3/4" and 1". Straight Female Steel "ST" Connectors (Page 6) with threaded hubs in sizes 3/s" to 1". Appleton's "ST" and "STB" Connectors (Pages 5,6) with an integral copper grounding lug to provide visible positive external ground. Straight connectors in sizes 3/a" to 6", and 45° and 90° connectors in sizes 3 /s" to 4". For use with liquidtight flexible metal conduit where an external visible equipment bonding jumper is desired and permitted by the 1981 National Electrical Code Sections 250-79(e), 501 -16(b)and 502-16(b) (where external equipment bonding jumpers are permitted, they will be limited to lengths not exceeding 6 feet and will be routed parallel to the conduit enclosure). Bonded steel zinc electroplated lugs are adequately sized to provide excellent grounding continuity and allow for visible ground path inspection. The ground wire is easily installed using only an Alien head wrench. Liquidtight connectors with grounding lugs can also be provided with Appleton's "STN," "STL" and "Female ST" Connectors (refer to factory). "STG" Series Liquidtight Neoprene Sealing Gaskets (Page 10) for use where "ST" fittings are terminated into J.I.C. boxes or panelboards. Sizes 1 /z" thru 6" fit all Appleton "ST" series connectors. The unique Appleton ferrule, long the industry leader, provides maximum surface contact for better sealing and grounding and in preventing sleeving. This exclusive ferrule design has now been modified even further by the addition of longer, more pronounced threads that provide over four times UL pull-out requirements. Underwriters Laboratories list all Appleton ST STB and STN series connectors up to the 4" size. The 5" and 6" size connectors, though manufactured to the same rigid standards, cannot be listed as UL does not yet recognize or list larger size conduit. They are suitable for hazardous location use as covered by the National Electrical Code: Article 501 -4 (b): Class I, Di v. 2; Article 502-4 (a) 2: Class II, Div. 1 and 2; Article 503-3 (a): Class III, Div. 1 and 2. 1701 W. Wellington Ave. Chicago, Illinois 60657 Copyright 1990 Printed in U.S.A. Suitable for Hazardous Location Class I, Div. 2; Class II, Div. 1 and 2; Class III, Div. 1 and 2; NEC 501-4(b), 502-4(a) (2), 503-3(a) ST File #14814A File #65178 Liquidtight "STB" Insulated Flexible Metal Conduit Connectors Size Catalog No. Wt. Lbs. Per 100 Ctn. Qty. Std. Pkg. 15.0 16.0 23.0 34.0 25 25 25 5 100 100 50 25 84.0 119.0 170.0 340.0 450.0 530.0 655.0 1200.0 1900.0 5 2 1 1 1 1 1 — 25 10 5 5 5 5 5 1 1 18.0 18.0 30.0 49.0 25 25 25 5 50 50 50 25 102.0 160.0 230.0 760.0 1000.0 1800.0 5 2 1 1 — — 25 10 5 5 1 1 23.0 24.0 38.0 58.0 25 25 10 5 50 50 50 25 116.0 192.0 282.0 840.0 1100.0 2150.0 5 2 1 1 — — 25 10 5 5 1 1 Straight STB-38 STB-50 STB-75 STB-100 Steel 3 /8"—1" Malleable Iron 1 '/V—6" 3 /8 flex, 1/2 hub 1/2 3/4 1 1</< STB-125 STB-150 STB-200 STB-250 STB-300 STB-350 STB-400 STB-SOOf STB-600t 11/2 2 2V2 3 3V2 4 5 6 ~ 45° STB-4538 STB-4550 STB-4575 STB-45100 With Steel Caps 3/a"—1" Malleable Iron %"—4" 3 /s flex, 'A hub 1 A 3/4 1 iv« 11/2 STB-45125 STB-45150 STB-45200 STB-45250 STB-45300 STB-45400 2 2 1 /2 3 4 90° STB-9038 STB-9050 STB-9075 STB-90100 With Steel Caps3 3/8"—1" Malleable Iron /e"—4" U.S. Pat 2,782,060 2,687,767 Can. Pat 507,070 708,255 STB-90125 STB-90150 STB-90200 STB-90250 STB-90300 STB-90400 3 /a flex, 1/2 hub </2 1 3/4 iy< 1V2 2 2V2 3 4 fUL Listing Not Applicable Discount Schedule ST Refer to Pricing Index for Prices. leton ELECTRIC COMMNY Copyright 1988 Printed in U.S.A. 1701 W. Wellington Ave. Chicago, Illinois 60657 Effective November, 1993 Page 5