650 Series Keyswitches Installation Instructions & Template 653071 Information 653 Models mount in a standard single-gang box as shown below. Template may be cut out or follow dimensions for prep of mounting area. See other side for special application notes. Template DO NOT PHOTOCOPY THIS DOCUMENT! TEMPLATE MUST BE TO SCALE. Standard Keyswitch 5A @ 30VAC/VDC ATS switch closes when cover is on. 0.025A @ 28VDC Blocking Ring required for cylinders over 1-1/8" Thickness = cylinder length - 1-1/8" White Red C NO White NO NO White LED indicator lights operate @ 12-24VDC 0.025A @ 28VDC Anti-Pullout Tab (optional) Recommended Cams: Modular Cams Black NC Red (+) Black (-) Non-Modular Cams L583-476 B502-191 L583-477 B502-948 Recommended cutout for 653 Keyswitches. 1-1/2 6-32 thread 2X 1-1/4 1/4" hole Drill 4X 1/16" Hex set screw Anti-Tamper Plugs (HDP only) Remove material to a depth of 1-3/4" minimum 2-5/8 CL 2-7/8 3-1/4 © 2013 Ingersoll Rand Printed in U.S.A. (877) 671-7011 653071 Rev. 07/13-e CL Functions The 653 Keyswitch comes with all parts (except switch assemblies) to make any function shown below. If switch assemblies are needed, order P/N P653059. Stop Pins Stop Magnet NOTE: The Keyswitch uses magnetic springs to activate. Dot facing up on Spring Magnet configures momentary action; dot down configures maintained action. For maintained key, remove one position (041 and 141 functions). Stop pins will be needed. Function Switch Configuration Magnet Configuration Spring Magnet Dot Up Dot Down (Magnets can be removed, flipped and reinstalled using a steel tool as shown.) 653-0404 CCW-SPDT-CW Maintained Maintained Function 653-1414 CCW-DPDT-CW Maintained Maintained 653-0505 CCW-SPDT-CW Momentary Momentary 653-1515 CCW-DPDT-CW Momentary Momentary 653-0405 CCW-SPDT-CW Momentary Momentary Switch Configuration 653-04 SPDT-CW Maintained 653-05 SPDT-CW Momentary 653-14 DPDT-CW Maintained 653-15 DPDT-CW Momentary 653-1415 CCW-DPDT-CW Momentary Momentary Verify switch cover is oriented correctly for switch configuration. Note that only one, two or four switches can be installed. Three is not recommended. Install 2 stop pins as shown. 653-041 CCW-SPDT Maintained Key can not be removed when switch is activated. 653-141 CCW-DPDT Maintained Key can not be removed when switch is activated. Magnet Configuration