650 Series Keyswitches

advertisement
650 Series Keyswitches
Installation Instructions & Template
653071
Information
653 Models mount in a standard single-gang box as shown below. Template may be cut out or follow dimensions for prep of mounting area.
See other side for special application notes.
Template
DO NOT PHOTOCOPY THIS DOCUMENT!
TEMPLATE MUST BE TO SCALE.
Standard Keyswitch
5A @ 30VAC/VDC
ATS switch closes
when cover is on.
0.025A @ 28VDC
Blocking Ring required for cylinders over 1-1/8"
Thickness = cylinder length - 1-1/8"
White
Red
C
NO
White
NO
NO
White
LED indicator lights
operate @ 12-24VDC
0.025A @ 28VDC
Anti-Pullout Tab (optional)
Recommended Cams:
Modular Cams
Black
NC
Red (+)
Black (-)
Non-Modular Cams
L583-476
B502-191
L583-477
B502-948
Recommended cutout for 653 Keyswitches.
1-1/2
6-32 thread
2X
1-1/4
1/4" hole
Drill 4X
1/16"
Hex set screw
Anti-Tamper Plugs
(HDP only)
Remove material to a
depth of 1-3/4" minimum
2-5/8
CL
2-7/8
3-1/4
© 2013 Ingersoll Rand
Printed in U.S.A.
(877) 671-7011
653071 Rev. 07/13-e
CL
Functions
The 653 Keyswitch comes with all parts (except switch assemblies) to make any function shown below.
If switch assemblies are needed, order P/N P653059.
Stop Pins
Stop Magnet
NOTE: The Keyswitch uses magnetic springs to activate.
Dot facing up on Spring Magnet configures momentary
action; dot down configures maintained action. For
maintained key, remove one position (041 and 141
functions). Stop pins will be needed.
Function
Switch Configuration Magnet Configuration
Spring Magnet
Dot Up
Dot Down
(Magnets can be
removed, flipped and
reinstalled using a
steel tool as shown.)
653-0404
CCW-SPDT-CW
Maintained Maintained
Function
653-1414
CCW-DPDT-CW
Maintained Maintained
653-0505
CCW-SPDT-CW
Momentary Momentary
653-1515
CCW-DPDT-CW
Momentary Momentary
653-0405
CCW-SPDT-CW
Momentary Momentary
Switch Configuration
653-04
SPDT-CW
Maintained
653-05
SPDT-CW
Momentary
653-14
DPDT-CW
Maintained
653-15
DPDT-CW
Momentary
653-1415
CCW-DPDT-CW
Momentary Momentary
Verify switch cover is oriented correctly for switch configuration. Note that
only one, two or four switches can be installed. Three is not recommended.
Install 2 stop pins as shown.
653-041
CCW-SPDT
Maintained
Key can not be
removed when switch
is activated.
653-141
CCW-DPDT
Maintained
Key can not be
removed when switch
is activated.
Magnet Configuration
Download