OVERCURRENT PROTECTION RELAYS CKR Series CKR-81T-96 (96x96mm) CKR-93T (144x144mm) t (sec.) Current-Time Characteristics I1 = (t) R1 Power source I2 = (t) R2 I3 = (t) R3 I4 (t) < I3 (t) < I2 (t) < I1 (t) I4 = (t) Functions Single-phase protection Two-phase protection Three-phase protection Earth fault protection Time and current setting Overcurrent pick-up I> Overcurrent instant I>> 0.2 - 3.35 x In, Step 0.25 2 - 17 x (I>), Step 1 Definite time 2.5, 5, 15 sec. 0.1-1 Step 0.1 Inverse time According IEC255, ANSI (normal, very, extremely, longtime, moderately) CKR-9XT series don't have moderately inverse time. Time multiplier for curves 0.1-1, Step 0.1 Parameters Électriques Electrical Parameters R4 I1 (t)-R1 I2 (t)-R2 I3 (t)-R3 I4 (t)-R4 Energy flow direction 1 10 20 24 V DC, Operating Voltage(Un) IA / I A. CKR- 9XX series have the following I/t characteristics. According to IEC-255, BS-142 these are: a - Normal Inverse b - Very Inverse c - Extremely Inverse d - Long Time Inverse e - Independent Time 1 (2.5 sec.) f - Independent Time 2 ( 5 sec.) g - Independent Time 3 (10 sec.) h - Independent Time 4 (15 sec.) The instantaneous tripping current, the time multiplication factor, and current-time characteristics adjustments both for the phases and neutral can be selected separately. 220 V DC 24 V DC, 230VAC±10% 85-265 V AC / DC ±10% 50/60 Hz 50/60 Hz Operating Current(In) Power Consumption Burden 1 A (earth), 5 A (phase) < 2 VA < 3 VA 1 C/O for earth 1 C/O for phase (8 A, 2000 VA, resistive) Relay output Current 5% In or Iset; Time 7,5% or ±40 msec. Accuracy Parameters Mécaniques Mechanical Parameters Non-flammable enclosure Double Insulation ( ), Measurement Category III Terminal Connection Flush mounting with rear terminals 31 CKR SERIES IP40 (front panel) IEC 60255-3 IEC 60255-6 IEC 529 CKS SERIES IP51 (front panel) IEC 60255-3 IEC 60255-6 IEC 60870-5 IEC 60529 CKR-93T CKR-92T SPECIFICATIONS CKR-91T Microcontroller based CKR series overcurrent relays combine both inverse time and independent time relays in one unit. These relays are used for protecting transformers, motors, generators, and power lines in energy distribution systems against short circuits and grounding faults. The most important point to achieve the uppermost protection is to apply “selective protection”. The main purpose of selective protection is locating and disconnecting the faulty circuit from the network as soon as possible but leaving the rest of the network active. The accurate protection by the inverse-time overcurrent relays can be accomplished with the following conditions : 1) Relays having the same operation characteristics should be used in series with each other. 2) Tripping intervals of the relays used within the system must be adjusted in the form of “current/time steps”. Current dependent tripping-time adjustment of the relays should be done in such a way that the “current/time steps” should be reduced as getting away from the source. Thus, the relay at the end of the line (R4 in the following figure) should have the shortest tripping time. This situation can be best observed from the schematics and current-time characteristics below: CKR-81T-96 MODELS General Operating Temperature Dimension Packing Weight Quantity in 1 package -5°C, +55°C 96x96mm (PR24) 144x144mm (PR17) 0,7 kg 1,5 kg 16 pcs 4 pcs OVERCURRENT PROTECTION RELAYS CKR Series Dimensions Connection Diagram 122 103 A- Single Phase Overcurrent Protection Device L1 7 8 9 1 L1 2 10 k L K l k L l K k L 140 14 15 l 3 4 11 12 13 ECU K IL 140 L2 140 L3 105 + 5 TYPE PR 17 + 6 85 70 Ko Auxiliary device ER-3Y 90 96 Ao 96 95 TYPE PR 24 7 8 9 2 3 IE 4 11 k K K l L l L 12 13 k l K k K k K k L l L l L l + 5 14 15 E ECU L k 7 8 9 10 11 12 13 14 15 1 10 K L1 + 6 B 3 - Earth Fault Overcurrent Protection Device L3 1 L3 L2 IL Ao 6 3 5 E 4 4 L1 7 8 9 10 11 12 13 14 15 L1 7 8 9 3 + 5 K + k K k K k 24VDC OR 2 220/230 VAC 6 Ko Auxiliary device ER-3Y L2 2 ECU L1 L2 ECU ECU L2 L3 L l L l L 1 l 1 2 3 IE 4 ECU L3 B2 - Earth Fault Overcurrent Protection Device + B1- Earth Fault Overcurrent Protection Device + 5 + 6 Ko Auxiliary device ER-3Y Ao The shown diagrams are only for typical application purposes. L1 7 8 9 10 L k l K L k K l L k l 14 15 L2 IL L3 L2 E-Three Phase and Earth Fault Overcurrent Protection Device L3 L1 7 8 9 L3 3 10 L2 + 5 E K k K k K + 6 Ko Auxiliary device ER-3Y L l L l L IL 3 L1 Ao K + 14 15 l 7 8 9 10 4 11 12 13 k L1 2 4 L1 L2 1 2 k K k K k 5 + 6 L l L l L l Ko Auxiliary device ER-3Y IE L3 L2 1 2 IL 3 4 11 12 13 L1 14 15 E + 5 + 6 Ko Auxiliary device ER-3Y Ao Ao pcs / carton K 11 12 13 1 IE ECU L2 ECU L3 D-Three Phase Overcurrent Protection Device ECU C-Two Phase and Earth Fault Overcurrent Protection Device Product Code CKR-93T 3 Phase + 1 Earth (Adjustable Inverse and Fixed Times for Phase & Earth) 85-265 VAC / DC 4 CKR-92T 2 Phase + 1 Earth ( '' '' 4 '' '' '' '' '' '' '' '' ) 32 OVERCURRENT PROTECTION RELAYS CKR Series Tp Tp Tp Tp: Time multiplier 33 Tp Tp