Reference Colour Tags Combined Overcurrent & Earth Fault Relay ccontents on onten ontent s MK2200 MK1000A Overcurrent Relay MK233A MK234A MK203A MK204A Earth Fault Relay MK231A MK232A MK201A MK202A Earth Leakage Relay Volt & Amp Meter Voltage Relay Reverse Power Relay Voltage & Current Control Relay Power Factor Regulator Annunciator MK300A / 300EA MK330A MK301A / 302A / 301E DIN330 DIN310 / 310E DIN300 / 300E ZCT40S / 60S / 80S / 120S DVM DAM MU2300 MU250 / 150 RPR415 MX200A / 180A / 160A MX100 / 50 PFR140 / 120 / 80 / 60 PFR96 / PFR96P AN112 / 120 Print Edition April 2010 ( 423468-T ) No.1 Jalan TP 7/7, Sime UEP Industrial Park, 40400 Shah Alam, Selangor, Malaysia. Website: www.itmikro.com Tel: +60-3-5192-7155 Fax: +60-3-5192-7166 Mikro® reserves the right to make changes without further notice to any products herein to improve reliability, function or design. The figures shown are without obligation. Functions The MK2200 combined overcurrent and earth-fault relay is a digital microprocessor based relay. This relay employs extensive advance numerical techniques implemented in real-time, for the computation of measured input quantity. Other advance features include programmable control output, metering and fault data recording. 1 Phase Overcurrent Protection Application The MK2200 combined overcurrent and earth-fault relay is used where time graded overcurrent and earth fault protection is required. Features • Multifunction numerical relay • Three-phase, low-set and high-set phase overcurrent • Two sets of low-set and high-set setting for phase overcurrent • Low-set and high-set earth fault • Two sets of low-set and high-set setting for earth fault • Circuit breaker failure protection • Four selectable IDMT characteristic curves • Definite time for low-set and high-set • Numeric display of phase and earth fault currents • Display of relay settings • 9 non- volatile records of previous tripping currents • Recording of relay start time • Highly flexible programmable relay outputs • Multifunction external digital input • Isolated RS485 Modbus - RTU communication • Selectable 50 Hz / 60 Hz When the phase current exceeds the lowset I> setting value, the overcurrent low-set element starts and delivers a start signal to the display panel and a group of preassigned relay outputs. After a delay time, determined by the inverse time current characteristic curve selected and the measured current or by definite time t>, this overcurrent element operates and delivers a trip signal to the display panel and a group of relay outputs that are configured to link to the low-set phase overcurrent tripping. When the phase current exceeds the highset I>> setting value, the overcurrent high-set element starts and delivers a start signal to the display panel and a group of preassigned relay outputs. After a preset time, determined by t>>, this overcurrent element operates and delivers a trip signal to the display panel and a group of relay outputs that are configured to link to highset phase overcurrent tripping. 2 Earth-Fault Protection When the earth-fault current exceeds the low-set Io> setting value, the earth-fault low-set element starts and delivers a start signal to the display panel and a group of preassigned relay outputs. After a delay time, determined by the inverse time current characteristic curve selected and the measured current or by definite time to>, this earth-fault element operates and delivers a trip signal to the display panel and a group of relay outputs that are configured to link to the low-set earth-fault tripping. When the earth-fault current exceeds the high-set Io>> setting value, the earth-fault high-set element starts and delivers a start signal to the display panel and a group of preassigned relay outputs. After a preset time, determined by to>>, this earth-fault element operates and delivers a trip signal to the display panel and a group of relay outputs that are configured to link to highset earth-fault tripping. Combined Overcurrent & Earth Fault Relay Introduction MK2200 MK2200 MK2200 Combined Overcurrent & Earth Fault Relay 3 Low-set Characteristic Curves The inverse definite minimum time (IDMT) characteristic curves in MK2200 comply with BS142-3 and IEC60255-3. The selectable curves and characteristics are: • Normal inverse • Very inverse • Extremely inverse • Long-time inverse • Definite time 4 High-set Characteristic The high-set is selectable between definite time and instantaneous tripping characteristic. 5 External Binary Input The functions of the external binary input are: • Blocking the operation of one or more protection stages. • Remote trip reset. • Changing of protection group settings. • Tripping the MK2200 by an external device. 6 Relay Output There are five relay outputs that can be programmed to respond to the relay start signal, the trip signal, or both the start and trip signals. The sixth relay output functions as internal relay failure indicator. 7 Configuration The configuration of the relay is accomplished by software switches settable by the user from the front panel. 8 Metering and Fault Record This function enables the values of the phase current and the earth-fault current to be viewed by the user. In addition, the user can also views the measured values of the phase current and earth-fault current recorded at the moment of fault for the previous 9 fault records stored in non-volatile memory. Technical Data INPUTS Measuring input: OUTPUTS 5 programmable contacts +1 IRF contact: Rated current In :1 A or 5 A Rated frequency :50 or 60 Hz Thermal withstand :4 x In continuous 25 x In for less than 10 sec 100 x In for less than 1 sec Burden :< 0.3VA at In Rated voltage Continuous carry Make and carry for 0.2 s Rated auxiliary voltage: Model MK2200-150D Model MK2200-240A Model MK2200-240AD : 24~150 V DC :198~265 V AC : 85~265 V AC 110~340 V DC Power consumption: AC auxiliary voltage DC auxiliary voltage : 6 ~ 10 VA typical : 5 ~ 9 W typical Binary Input: External binary input : 18 ~ 265 V DC 85 ~ 265 V AC EARTH-FAULT ELEMENT : 250 V AC/DC :5A : 30 A Contact specification: Expected electrical life : 100,000 operations Expected mechanical life : 5 x 106 operations ACCURACY Protection thresholds : ± 3% Time delay : ± 2% with a minimum of 30 ms Measurements : ± 3% Reset ratio : 95% typical Overshoot time : less than 30 ms typical ENVIRONMENTAL CONDITIONS Temperature : -5˚C to +55˚C Humidity : 56 days at 93% RH and 40˚C non-condensing Low-set setting I o> : 0.05 ~ 1.0 x In , step 0.01 High-set setting I o>> : 0.05 ~ 10.0 x In , step 0.05 Time multiplier kt o> : 0.02 ~ 1.0 , step 0.01 Low set definite time t o> : 0 ~ 300 s 0 ~ 10.0s : step 0.01 High set definite time t o>>: 0 ~ 300 s 10.0 ~ 100s : step 0.1 100 ~ 300s : step 1 OVERCURRENT ELEMENT Low-set setting I > : 0.10 ~ 2.50 x In , step 0.01 High-set setting I >> : 0.10 ~ 40 x In , step 0.05 ( 0.1 ~ 10 In ), step 0.1 ( 10 ~ 40 In ) Time multiplier kt > : 0.02 ~ 1.0 , step 0.01 Low set definite time t > : 0 ~ 300 s 0 ~ 10.0s : step 0.01 High set definite time t >> : 0 ~ 300 s 10.0 ~ 100s : step 0.1 100 ~ 300s : step 1 COMMUNICATION RS485 Modbus - RTU Tests And Standards High voltage dielectric withstand test IEC60255-5 High voltage impulse test IEC60255-5 Electrical fast transient IEC61000-4-4, Level 4, power supply inputs Electrical fast transient IEC61000-4-4, Level 4, other inputs Electrostatic discharge IEC61000-4-2, Class III, air discharge Electrostatic discharge IEC61000-4-2, Class III, contact discharge 1MHz Burst Disturbance IEC60255-22-1 Mains conducted disturbance voltage Radiated EM Field emission Enclosure protection when panel mounted 2.0 KV rms, 1 min 5 KV, 1.2/50ms 4 KV, 5/50ns 2 KV, 5/50ns 8 KV 6 KV 2 KV Common mode 1 KV Differential mode EN 55011 Group 1 Class B CISPR 11 Group 1 Class B IP54 t/s t/s 10 10 k k 1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 1 1.0 0.8 0.6 0.5 0.4 0.3 0.2 0.3 0.2 0.1 0.1 0.05 0.1 0.1 0.05 1 10 20 I/I > EXTREMELY INVERSE 0.01 1 10 20 I/I > LONG-TIME INVERSE t/s t/s 100 200 100 10 10 k 1.0 0.8 0.6 0.5 0.4 0.3 1 k 1.0 0.8 0.6 0.5 0.4 0.3 0.1 0.05 0.01 1 10 0.2 1 0.1 0.2 0.1 20 I/I > 0.05 0.1 1 10 20 I/I > Combined Overcurrent & Earth Fault Relay VERY INVERSE MK2200 NORMAL INVERSE TYPICAL APPLICATION DIAGRAM 1 COM 5A 34 36 35 3 1A Trip Contact R1 4 5 COM 5A 38 37 R2 6 1A 7 8 COM 5A 40 39 R3 9 1A 42 41 R4 27 26 R5 10 COM 11 5 A 12 1 A MK2200 External Binary Input Auxiliary input Uaux 13 14 28 30 29 22 165 mm 142 mm 1 2 Front 198 mm Internal Relay Failure 32 33 23 Termination Resistor RS485 N- 24 P+ 31 25 Communication Cable Shield 34 mm 136 mm Combined Overcurrent & Earth Fault Relay L1 L2 L3 CASE DIMENSIONS Side TYPICAL APPLICATION DIAGRAM 2 129 1 mm 1 2 COM 5A 3 1A 4 5 COM 5A 38 37 R2 6 1A 7 8 COM 5A 40 39 R3 9 1A 42 41 R4 27 26 R5 10 COM 11 5 A 12 1 A External Binary Input Auxiliary input Uaux 13 14 34 36 35 28 30 29 22 Trip Contact R1 Internal Relay Failure 32 33 23 Termination Resistor RS485 N- 24 P+ 31 25 Communication Cable Shield Ordering Information MODEL DESCRIPTION MK2200 - 150D MK2200 - 240A MK2200 - 240AD For 50/60 Hz system, auxiliary voltage 24 ~ 150 V DC For 50/60 Hz system, auxiliary voltage 198 ~ 265 V AC For 50/60 Hz system, auxiliary voltage 84 ~ 265 V AC or 110 ~ 340 V DC 139 1 mm L1 L2 L3 N Panel Cutout Features Technical Data • Current measurement based on RATINGS • Microprocessor based numerical relay fundamental frequency • Three-phase, low-set overcurrent • Three-phase, high-set overcurrent • Low-set earth-fault • High-set earth-fault • Definite time for low-set and high-set • Five selectable IDMT characteristic curves • Local display of measured and set values • Programmable relay outputs • Non-volatile fault values recording • Complies with IEC 60255-26 standard Rated current ( In ) Rated frequency Burden Themal withstand AUXILIARY SUPPLY Model MK1000A-240A(6) : 198 ~ 265 V AC Model MK1000A-240AD(6) : 85 ~ 265 V AC 110 V DC ~ 370 V DC Model MK1000A-150D(6) : 24 ~ 150 V DC Supply frequency : 50 or 60 Hz V A rating : 3 VA typical ACCURACY Protection thresholds Time delay SETTING RANGES i ) Overcurrent elements Low-set ( I > ) : 0.5 A to 10.0 A, step 0.05 A : 10% to 200%, step 1% Low-set time multiplier ( kt >): 0.05 to 1.0, step 0.01 Low-set definite time ( t > ) : 0.05 to 99s High-set ( I >> ) : 0.5 A to 99.9 A, step 0.10 A or disable : 10% to 1998%, step 2% High-set delay time ( t >> ) : 0.05 sec to 2.5 sec, step 0.01 ii ) Earth-fault element Low-set ( I o > ) : 0.10 A to 5.0 A, step 0.05 A : 2% to 100% Low-set time multiplier(kt o>): 0.05 to 1.0, step 0.01 Low-set definite time ( t o > ): 0.05 to 99s High-set ( I o >> ) : 0.10 A to 50 A, step 0.10 A or disable : 2% to 1000%, step 2% High-set delay time ( t o >> ) : 0.05 sec to 2.5 sec, step 0.01 : 5A : 50 or 60 Hz : < 0.3 VA at In : 4 x In continuous : ± 5% : ± 5% with a minimum of 50 ms CONTACTS Trip Contacts ( R1 & R2 ) Rated voltage Contacts arrangement Contact rating Contact material Expected electrical life : 250V AC/DC : Change-over : 5A : Silver alloy : 100,000 operations at rated current Expected mechanical life : 5 x 106 operations INDICATORS Auxiliary supply Pick-up Trip : Green indicator : Red indicator : 7-segment display and red indicators MECHANICAL Mounting Front panel Approximate weight : Panel mounting : Standard DIN 96 mm x 96 mm : 0.75 kg ENVIRONMENTAL CONDITIONS Temperature : -5˚C to +55˚C Humidity : 56 days at 93% RH and 40˚C non-condensing MK1000A Combined Overcurrent & Earth Fault Relay MK1000A VERY INVERSE MK1000A Combined Overcurrent & Earth Fault Relay NORMAL INVERSE LONG TIME INVERSE TYPICAL APPLICATION DIAGRAM Aux L N NO 1 EXTREMELY INVERSE 2 3 NC COM COM NC 4 5 R1 NORMAL INVERSE 1.3/10 9 10 11 12 13 6 7 8 15 16 R2 14 L1 L2 L3 N CASE DIMENSIONS 96 mm 96 mm Front 110 mm 100 mm Side Ordering Information DESCRIPTION MK1000A-240A MK1000A-240AD MK1000A-150D MK1000A-240AD6 MK1000A-150D6 For 50Hz system, auxiliary voltage 198 ~ 265 V AC For 50Hz system, auxiliary voltage 85 ~ 265 V AC or 110~370 V DC For 50Hz system, auxiliary voltage 24 ~ 150 V DC For 60Hz system, auxiliary voltage 85 ~ 265 V AC or 110~370 V DC For 60Hz system, auxiliary voltage 24 ~ 150 V DC 91.0 ± 0.5 mm Panel Cutout 91.0 ± 0.5 mm MODEL MK1000A NO MK233A Features • Microprocessor based numerical relay • Definite time for low-set and high-set • Current measurement based on • Non-volatile fault value recording fundamental frequency • Three-phase, low-set overcurrent • Five selectable IDMT characteristic curves • Three-phase, high-set overcurrent • Complies with IEC 60255-26 standard • Local display of measured and set values Technical Data RATINGS Rated current ( In ) Rated frequency Burden Thermal withstand : 5A : 50 or 60 Hz : < 0.3 VA at In : 4 x In continuous AUXILIARY SUPPLY Model MK233A-240A (6) Model MK233A-110A (6) Supply frequency VA rating : 198 ~ 265 V AC : 94 ~ 127 V AC : 50 or 60 Hz : 3 VA typical SETTING RANGES Low-set ( I > ) Low-set time multiplier ( kt > ) Low-set definite time (t >) High-set ( I >> ) High-set delay time ( t >> ) : : : : : 0.5 A to 6.0 A, step 0.05 A / 10% to 120%, step 1% 0.05 to 1.0, step 0.01 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.1 to 99) 0.5 A to 99.9 A or disable, step 0.10 A / 10% to 1998%, step 2% 0.05 sec to 2.5 sec, step 0.01 ACCURACY Protection thresholds Time delay : ± 5% : ± 5% with a minimum of 50 ms CONTACTS ( R1 & R2 ) Contact arrangement Contact rating Contact material Expected electrical life Expected mechanical life : : : : : Change-over 5 A, 250 V AC ( cosϕ = 1 ) Silver alloy 100,000 operations at rated current 5 x 106 operations INDICATORS Auxiliary supply Pick-up Trip : Green indicator : Red indicator : 7-segment display and red indicators MECHANICAL Mounting Front panel Approximate weight : Panel mounting : Standard DIN 96 mm x 96 mm : 0.7 kg ENVIRONMENTAL CONDITIONS Temperature Humidity : -5˚C to +55˚C : 56 days at 93% RH and 40˚C non-condensing MK233A Overcurrent Relay • Programmable relay outputs VERY INVERSE MK233A Overcurrent Relay NORMAL INVERSE LONG TIME INVERSE TYPICAL APPLICATION DIAGRAM Aux L N NO 1 EXTREMELY INVERSE 2 3 NC COM COM NC 4 NORMAL INVERSE 1.3/10 5 6 R1 9 10 11 12 13 MK 233A NO 7 8 15 16 R2 14 L1 L2 L3 N CASE DIMENSIONS 96 mm 96 mm Front 110 mm 100 mm Side Ordering Information DESCRIPTION MK233A - 240A MK233A - 110A MK233A - 240A6 MK233A -110A6 For 50 Hz system, auxiliary voltage198 ~ 265 V AC For 50 Hz system, auxiliary voltage 94 ~ 127 V AC For 60 Hz system, auxiliary voltage198 ~ 265 V AC For 60 Hz system, auxiliary voltage 94 ~ 127 V AC 91.0 ± 0.5 mm Panel Cutout 91.0 ± 0.5 mm MODEL MK234A • Definite time for low-set and high-set • Current measurement based on • Non-volatile fault value recording fundamental frequency • Three-phase, low-set overcurrent • Three-phase, high-set overcurrent • Programmable relay outputs • Complies with IEC 60255-26 standard • Local display of measured and set values Technical Data RATINGS Rated current ( In ) Rated frequency Burden Thermal withstand : 5A : 50 or 60 Hz : < 0.3 VA at In : 4 x In continuous AUXILIARY SUPPLY Model MK234A-240A(6) Model MK234A-110A(6) Supply frequency VA rating : 198 ~ 265 V AC : 94 ~ 127 V AC : 50 or 60 Hz : 3 VA typical SETTING RANGES Low-set ( I > ) Low-set definite time ( t > ) High-set ( I >> ) High-set delay time ( t >> ) : : : : 0.5 A to 6.0 A, step 0.05 A / 10% to 120%, step 1% 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.1 to 99) 0.5 A to 99.9 A or disable, step 0.10 A / 10% to 1998%, step 2% 0.05 sec to 2.5 sec, step 0.01 ACCURACY Protection thresholds Time delay : ± 5% : ± 5% with a minimum of 50 ms CONTACTS ( R1 & R2 ) Contact arrangement Contact rating Contact material Expected electrical life Expected mechanical life : : : : : Change-over 5 A, 250 V AC ( cosϕ = 1 ) Silver alloy 100,000 operations at rated current 5 x 106 operations INDICATORS Auxiliary supply Pick-up Trip : Green indicator : Red indicator : 7-segment display and red indicators MECHANICAL Mounting Front panel Approximate weight : Panel mounting : Standard DIN 96 mm x 96 mm : 0.7 kg ENVIRONMENTAL CONDITIONS Temperature Humidity : -5˚C to +55˚C : 56 days at 93% RH and 40˚C non-condensing MK234A Overcurrent Relay Features • Microprocessor based numerical relay TYPICAL APPLICATION DIAGRAM Aux L N NO 1 2 3 NC COM COM NC 4 5 R1 10 11 12 13 7 8 15 16 R2 14 L1 L2 L3 N CASE DIMENSIONS 96 mm 96 mm Front 110 mm 100 mm Side 91.0 ± 0.5 mm Panel Cutout Ordering Information MODEL DESCRIPTION MK234A - 240A MK234A - 110A MK234A - 240A6 MK234A -110A6 For 50 Hz system, auxiliary supply 198 ~ 265 V AC For 50 Hz system, auxiliary supply 94 ~ 127 V AC For 60 Hz system, auxiliary supply 198 ~ 265 V AC For 60 Hz system, auxiliary supply 94 ~ 127 V AC 91.0 ± 0.5 mm MK234A Overcurrent Relay 9 6 MK 234A NO MK203A • Microprocessor based numerical relay • Current measurement based on fundamental frequency • Low-set inverse definite minimum time ( IDMT ) relay • High-set instantaneous relay • Separate low-set and high-set trip indicators Technical Data RATINGS Rated current ( In ) Rated frequency Burden Thermal withstand :5 A :50 Hz :< 0.3 VA at In :4 x In continuous AUXILIARY SUPPLY Model MK203A-240A : 198 ~ 265 V AC Model MK203A-110A :94 ~ 127V AC Supply frequency :50 Hz VA rating : 3 VA typical • Option to disable high-set relay SETTING RANGES • Front panel access to test function Low-set ( I > ) :2.0 A to 6.0 A :40% to 120% Time multiplier ( TM ) :0.05 to 1.0 High-set ( I >> ) :I > to 10 x I > or disable High-set delay time (t >>) : Instantaneous • Complies with IEC 60255-26 standard TIME CURRENT CHARACTERISTIC CURVE - Normal Inverse CONTACTS Trip contact (R1) :Manual reset type Contact Arrangement:Change-over Contact rating :5 A, 250 V AC ( cosϕ = 1 ) Contact material :Silver alloy Expected electrical life:100,000 operations at rated current Expected mechanical life:5 x 106 operations INDICATORS Auxiliary supply Pick-up Trip :Green indicator :Red indicator :Red indicator PERFORMANCE Adjustable accuracy : Less than ±5%. Repeatability : Less than 0.5% of full scale. MECHANICAL Mounting Front panel : Panel mounting : Standard DIN 96 mm x 96 mm Approximate weight : 0.7 kg ENVIRONMENTAL CONDITIONS Temperature Humidity :-5˚C to +55˚C :56 days at 93% RH and 40˚C non-condensing MK203A Overcurrent Relay Features TYPICAL APPLICATION DIAGRAM Aux L N MK 203A NO 1 2 NORMAL INVERSE 3 NC COM 4 5 6 7 8 14 15 16 R1 10 11 12 13 L1 L2 L3 N COMBINED IDMT OVERCURRENT & EARTH FAULT RELAYS AUX L N 1 2 L MK 203A NO 3 AUX N NC COM 4 5 MK 202A NO 6 7 8 1 2 3 NC COM 4 9 10 11 12 13 5 6 7 8 14 15 16 R1 R1 14 15 16 9 10 11 12 13 L1 L2 L3 CASE DIMENSIONS 96 mm 110 mm 100 mm 91.0 ± 0.5 mm Front Side Panel Cutout Ordering Information MODEL DESCRIPTION MK203A - 240A MK203A - 110A For 50 Hz system, auxiliary voltage 198 ~ 265 V AC For 50 Hz system, auxiliary voltage 94 ~ 127 V AC 91.0 ± 0.5 mm N 96 mm MK203A Overcurrent Relay 9 Features Technical Data • Microprocessor based numerical relay RATINGS • Current measurement based on fundamental frequency • Low-set inverse definite time relay (IDT) • High-set instantaneous relay • Separate low-set and high-set trip indicators • Option to disable high-set relay • Front panel access to test function • Complies with IEC 60255-26 standard Rated current ( In ) Rated frequency Burden Thermal withstand :5 A :50 Hz :< 0.3 VA at In :4 x In continuous AUXILIARY SUPPLY Model MK204A-240A : 198 ~ 265 V AC Model MK204A-110A :94 ~ 127V AC Supply frequency :50 Hz VA rating : 3 VA typical SETTING RANGES Low-set ( I > ) :2.0 A to 6.0 A :40% to 120% Time multiplier ( TM ) :0.05 to 1.0 High-set ( I >> ) :I > to 10 x I > or disable High-set delay time (t >>) : Instantaneous CONTACTS Trip contact (R1) :Manual reset type Contact Arrangement:Change-over Contact rating :5 A, 250 V AC ( cosϕ = 1 ) Contact material :Silver alloy Expected electrical life:100,000 operations at rated current Expected mechanical life:5 x 106 operations INDICATORS Auxiliary supply Pick-up Trip :Green indicator :Red indicator :Red indicator PERFORMANCE Adjustable accuracy : Less than ±5%. Repeatability : Less than 0.5% of full scale. MECHANICAL Mounting Front panel : Panel mounting : Standard DIN 96 mm x 96 mm Approximate weight : 0.7 kg ENVIRONMENTAL CONDITIONS Temperature Humidity :-5˚C to +55˚C :56 days at 93% RH and 40˚C non-condensing MK204A Overcurrent Relay MK204A TYPICAL APPLICATION DIAGRAM Aux L N 2 t/s MK 204A NO 1 IDT INVERSE 3 NC COM 4 5 6 7 8 14 15 16 R1 10 11 12 13 10 L1 L2 k L3 1.0 0.9 0.8 0.7 0.6 0.5 0.4 N 1 0.3 0.2 0.1 0.1 1 10 20 I/I> COMBINED OVERCURRENT & EARTH FAULT RELAYS AUX L N 1 2 L MK 204A NO 3 AUX N NC COM 4 5 MK 201A NO 6 7 8 1 2 3 NC COM 4 9 10 11 12 13 5 6 7 8 14 15 16 R1 R1 14 15 16 9 10 11 12 13 L1 L2 L3 CASE DIMENSIONS 96 mm 110 mm 100 mm 91.0 ± 0.5 mm Front Side Panel Cutout Ordering Information MODEL DESCRIPTION MK204A - 240A MK204A - 110A For 50 Hz system, auxiliary voltage 198 ~ 265 V AC For 50 Hz system, auxiliary voltage 94 ~ 127 V AC 91.0 ± 0.5 mm N 96 mm MK204A Overcurrent Relay 9 MK231A Features • Microprocessor based numerical relay • Definite time for low-set and high-set • Current measurement based on • Non-volatile fault value recording fundamental frequency • Programmable relay outputs • Low-set earth-fault • Complies with IEC 60255-26 standard • High-set earth-fault • Local display of measured and set values RATINGS Rated current ( In ) Rated frequency Burden Thermal withstand : 5A : 50 or 60 Hz : < 0.3 VA at In : 4 x In continuous AUXILIARY SUPPLY Model MK231A-240A (6) Model MK231A-110A (6) Supply frequency VA rating : 198 ~ 265 V AC : 94 ~ 127 V AC : 50 or 60 Hz : 3 VA typical SETTING RANGES Low-set ( I > ) Low-set definite time ( t > ) High-set ( I >> ) High-set delay time ( t >> ) : : : : 0.1 A to 5.0 A, step 0.05 A / 2% to 100%, step 1% 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.1 to 99) 0.1 A to 50 A or disable, step 0.1 A / 2% to 1000%, step 2% 0.05 sec to 2.5 sec, step 0.01 ACCURACY Protection thresholds Time delay : ± 5% : ± 5% with a minimum of 50 ms CONTACTS ( R1 & R2 ) Contact arrangement Contact rating Contact material Expected electrical life Expected mechanical life : : : : : Change-over 5 A, 250 V AC ( cosϕ = 1 ) Silver alloy 100,000 operations at rated current 5 x 106 operations INDICATORS Auxiliary supply Pick-up Trip : Green indicator : Red indicator : 7-segment display and red indicators MECHANICAL Mounting Front panel Approximate weight : Panel mounting : Standard DIN 96 mm x 96 mm : 0.6 kg ENVIRONMENTAL CONDITIONS Temperature Humidity : -5˚C to +55˚C : 56 days at 93% RH and 40˚C non-condensing MK231A Earth Fault Relay Technical Data TYPICAL APPLICATION DIAGRAM Aux L N NO 1 2 3 NC COM COM NC 4 5 R1 9 10 11 12 13 6 MK 231A NO 7 8 15 16 R2 14 L1 L2 L3 N MK231A Earth Fault Relay CASE DIMENSIONS 96 mm 96 mm Front 110 mm 100 mm Side Panel Cutout Ordering Information MODEL DESCRIPTION MK231A - 240A MK231A - 110A MK231A - 240A6 MK231A -110A6 For 50 Hz system, auxiliary voltage 198 ~ 265 V AC For 50 Hz system, auxiliary voltage 94 ~ 127 V AC For 60 Hz system, auxiliary voltage 198 ~ 265 V AC For 60 Hz system, auxiliary voltage 94 ~ 127 V AC 91.0 ± 0.5 mm 91.0 ± 0.5 mm MK232A Features • Microprocessor based numerical relay • Definite time for low-set and high-set • Current measurement based on • Non-volatile fault value recording fundamental frequency • Programmable relay outputs • Low-set earth-fault • Five selectable IDMT characteristic curves • High-set earth-fault • Complies with IEC 60255-26 standard • Local display of measured and set values RATINGS Rated current ( In ) Rated frequency Burden Thermal withstand : 5A : 50 or 60 Hz : < 0.3 VA at In : 4 x In continuous AUXILIARY SUPPLY Model MK232A-240A (6) Model MK232A-110A (6) Supply frequency VA rating : 198 ~ 265 V AC : 94 ~ 127 V AC : 50 or 60 Hz : 3 VA typical SETTING RANGES Low-set ( I > ) Low-set time multiplier ( kt > ) Low-set definite time (t >) High-set ( I >> ) High-set delay time ( t >> ) : : : : : 0.1 A to 5.0 A, step 0.05 A / 2% to 100%, step 1% 0.05 to 1.0, step 0.01 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.1 to 99) 0.1 A to 50 A or disable, step 0.1 A / 2% to 1000%, step 2% 0.05 sec to 2.5 sec, step 0.01 ACCURACY Protection thresholds Time delay : ± 5% : ± 5% with a minimum of 50 ms CONTACTS ( R1 & R2 ) Contact arrangement Contact rating Contact material Expected electrical life Expected mechanical life : : : : : Change-over 5 A, 250 V AC ( cosϕ = 1 ) Silver alloy 100,000 operations at rated current 5 x 106 operations INDICATORS Auxiliary supply Pick-up Trip : Green indicator : Red indicator : 7-segment display and red indicators MECHANICAL Mounting Front panel Approximate weight : Panel mounting : Standard DIN 96 mm x 96 mm : 0.6 kg ENVIRONMENTAL CONDITIONS Temperature Humidity : -5˚C to +55˚C : 56 days at 93% RH and 40˚C non-condensing MK232A Earth Fault Relay Technical Data VERY INVERSE LONG TIME INVERSE TYPICAL APPLICATION DIAGRAM Aux L N NO 1 EXTREMELY INVERSE 2 3 NC COM COM NC 4 NORMAL INVERSE 1.3/10 5 6 R1 9 10 11 12 13 MK 232A NO 7 8 15 16 R2 14 L1 L2 L3 N CASE DIMENSIONS 96 mm 96 mm Front 110 mm 100 mm Side Ordering Information MODEL DESCRIPTION MK232A - 240A MK232A - 110A MK232A - 240A6 MK232A -110A6 For 50 Hz system, auxiliary voltage 198 ~ 265 V AC For 50 Hz system, auxiliary voltage 94 ~ 127 V AC For 60 Hz system, auxiliary voltage 198 ~ 265 V AC For 60 Hz system, auxiliary voltage 94 ~ 127 V AC 91.0 ± 0.5 mm Panel Cutout 91.0 ± 0.5 mm MK232A Earth Fault Relay NORMAL INVERSE 3/10 MK201A Features Technical Data • Microprocessor based numerical relay RATINGS • Current measurement based on • Low-set definite time relay Rated current ( In ) Rated frequency Burden Thermal withstand • High-set instantaneous relay AUXILIARY SUPPLY • Option to disable the high-set relay Model MK201A-240A : 198 ~ 265 V AC Model MK201A-110A : 94 ~ 127 V AC Supply frequency : 50 Hz VA rating : 3 VA typical • Front panel access to the test function SETTING RANGES • Separate low-set and high-set indicators • Complies with IEC 60255-26 standard PERFORMANCE Adjustable accuracy : Less than ±5% Repeatability : Less than 0.5% of full scale Low-set ( I > ) :0.1 A to 2.0 A :2% to 40% Low-set delay time(DELAY):0.05 sec to 1.0 sec High-set ( I >> ) :I > to 10 x I > or disable High-set delay time ( t >> ):Instantaneous CONTACTS : Panel mounting : Standard DIN 96 mm x 96 mm Approximate weight : 0.6 kg Trip contact (R1) :Manual reset type Contact Arrangement:Change-over Contact rating :5 A, 250 V AC ( cosϕ = 1 ) Contact material :Silver alloy Expected electrical life:100,000 operations at rated current Expected mechanical life: 5 x 106 operations ENVIRONMENTAL CONDITIONS INDICATORS Temperature Humidity Auxiliary supply Pick-up Trip MECHANICAL Mounting Front panel :-5˚C to +55˚C :56 days at 93% RH and 40˚C non-condensing : Green indicator : Red indicator : Red indicator MK201A Earth Fault Relay fundamental frequency :5 A :50 Hz :< 0.3 VA at In :4 x In continuous Aux L N 1 2 COMBINED OVERCURRENT & EARTH FAULT RELAYS 3 AUX L MK 201A NO NC COM 4 5 N MK 204A NO 9 10 11 12 13 L AUX N NC COM 6 7 8 1 2 3 4 14 15 16 9 10 11 12 R1 5 MK 201A NO NC COM 6 7 8 1 2 3 4 14 15 16 9 10 11 12 13 L2 L1 L3 L2 N L3 N 96 mm 90 mm 70 mm Front Side 91.0 ± 0.5 mm Panel Cutout Ordering Information MODEL DESCRIPTION MK201A - 240A MK201A - 110A For 50 Hz system, auxiliary voltage 198 ~ 265 V AC For 50 Hz system, auxiliary voltage 94 ~ 127 V AC 91.0 ± 0.5 mm CASE DIMENSIONS 5 6 7 8 14 15 16 R1 R1 L1 96 mm MK201A Earth Fault Relay TYPICAL APPLICATION DIAGRAM 13 MK202A Features Technical Data • Microprocessor based numerical relay RATINGS fundamental frequency • Low-set inverse definite minimum time ( IDMT ) relay • High-set instantaneous relay • Separate low-set and high-set trip indicators • Option to disable high-set element • Front panel access to test function • Complies with IEC 60255-26 standard Rated current ( In ) Rated frequency Burden Thermal withstand :5 A :50 Hz :< 0.3 VA at In :4 x In continuous AUXILIARY SUPPLY Model MK202A-240A : 198 ~ 265 V AC Model MK202A-110A :94 ~ 127V AC Supply frequency :50 Hz VA rating : 3 VA typical SETTING RANGES Low-set ( I > ) :0.1A to 2.0 A :2% to 40% Time multiplier ( TM ) :0.05 to 1.0 High-set ( I >> ) :I > to 10 x I > or disable High-set delay time (t >>) : Instantaneous TIME CURRENT CHARACTERISTIC CURVE - Normal Inverse CONTACTS Trip contact (R1) :Manual reset type Contact Arrangement:Change-over Contact rating :5 A, 250 V AC ( cosϕ = 1 ) Contact material :Silver alloy Expected electrical life: 100,000 operations at rated current Expected mechanical life: 5 x 106 operations INDICATOR Auxiliary indicator Pick-up Trip :Green indicator :Red indicator :Red indicator PERFORMANCE Adjustable accuracy : Less than ±5%. Repeatability : Less than 0.5% of full scale. MECHANICAL Mounting Front panel : Panel mounting : Standard DIN 96 mm x 96 mm Approximate weight : 0.6 kg ENVIRONMENTAL CONDITIONS Temperature Humidity :-5˚C to +55˚C :56 days at 93% RH and 40˚C non-condensing MK202A Earth Fault Relay • Current measurement based on TYPICAL APPLICATION DIAGRAM Aux L N MK 202A NO 1 IDMT NORMAL INVERSE 2 3 NC COM 4 5 6 7 8 14 15 16 R1 9 10 11 12 13 L1 L2 L3 COMBINED IDMT OVERCURRENT & EARTH FAULT RELAYS AUX L N 1 2 L MK 203A NO 3 AUX N NC COM 4 5 MK 202A NO 6 7 8 1 2 3 NC COM 4 9 10 11 12 13 5 6 7 8 14 15 16 R1 R1 14 15 16 9 10 11 12 13 L1 L2 L3 N 96 mm 90 mm 70 mm Front Side 91.0 ± 0.5 mm Panel Cutout Ordering Information MODEL DESCRIPTION MK202A - 240A MK202A - 110A For 50 Hz system, auxiliary voltage 198 ~ 265 V AC For 50 Hz system, auxiliary voltage 94 ~ 127 V AC 91.0 ± 0.5 mm CASE DIMENSIONS 96 mm MK202A Earth Fault Relay N MK300A/300EA MK300A Features for MK300A / 300EA Features for MK300EA only • Numerical earth leakage relay • Positive safety output contact • Programmable current sensitivity and time delay • Pre-fault alarm contact • Detection of no connection to ZCT • Remote reset function • Relay trip indicator • Relay alarm indicator • Real-time leakage current display • 50% pre-fault indicator • Leakage fault current recording MK300EA • Protected against nuisance tripping TYPICAL APPLICATION DIAGRAM For MK300A N AUX L1 L2 L3 N L PE MIKRO ZCT MK300A 1 2 4 5 6 7 8 12 13 14 15 16 3 The EARTH wire must not pass through the ZCT SHUNT TRIP TRIP CONTACT NC 9 NO COM 11 10 LOAD TYPICAL APPLICATION DIAGRAM For MK300EA N AUX L1 L2 L3 N REMOTE RESET L PE MIKRO ZCT MK300EA 1 2 3 TRIP CONTACT NC 9 NO 10 4 5 6 ALARM CONTACT COM NO 11 12 COM NC 13 8 7 CONTACTOR POSITIVE SAFETY CONTACT 14 NO 15 COM 16 LOAD The EARTH wire must not pass through the ZCT MK300A & MK300EA Earth Leakage Relay • Standard DIN 96x96mm panel mounting E Technical Data CASE DIMENSIONS AUXILIARY SUPPLY : 184 ~ 276 V AC : 94 ~ 127 V AC : 50 Hz : 3 VA typical SETTING Sensitivity adjustment : Time delay adjustment : 30mA, 50mA, 0.10~1.00A (Step=50mA) 1.00~10.0A (Step=1.00A) Instantaneous, 0.1~3.0sec (Step=0.1s) 96 mm 96 mm Model MK300A / 300EA -230A Model MK300A / 300EA -110A Rated frequency VA rating Front 90 mm 70 mm PERFORMANCE Setting accuracy Timing accuracy :-15% to +0% :±5% Side RECORD Fault record Storage : 3 latest tripped fault currents or “tSt” for manual test trip : Non-volatile memory 91.0 ± 0.5 mm MK300A & MK300EA Earth Leakage Relay Remote Test / Reset Inputs : N.O. dry contact * Panel Cutout OUTPUTS Trip contact Positive safety contact* Alarm contact* : Activated during leakage trip, manual test trip or ZCT connection error : Activated when power-up and relay function correctly : Activated when measured leakage current exceeded 50% of IΔn. CONTACTS Contact arrangement Contact rating Expected electrical life Expected mechanical life : : : : Change-over 5A(NO) / 3A(NC) / 250V AC1 10,000 operations at rated current 5 x 106 operations : : : : : Red indicator (Normal blink) Red indicator (Fast blink) 7-segment display and red indicator 7-segment display and red indicator 7-segment display INDICATORS Pre-fault alarm Time delay Leakage trip ZCT connection error Real-time leakage current ZERO - PHASE CURRENT TRANSFORMER To operate with Mikro’s ZCT series of current transformer MECHANICAL Mounting method Front panel Approximate weight : Panel mounting : Standard DIN 96mm x 96mm : 0.58kg (excluding ZCT) * Applicable to MK 300EA series only Ordering Information MODEL DESCRIPTION MK300A - 230A MK300EA - 230A MK300A - 110A MK300EA - 110A For 50Hz system, auxiliary voltage 184~276VAC For 50Hz system, auxiliary voltage 184~276VAC For 50Hz system, auxiliary voltage 94~127VAC For 50Hz system, auxiliary voltage 94~127VAC 91.0 ± 0.5 mm INPUT MK330A Features • Numerical auto-reclosing earth leakage relay • One programmable contact for flexibility • Detection of no connection to ZCT • Programmable current sensitivity and time delay • Relay trip indicator • Relay alarm indicator • Programmable dead time and number of shots • Real-time leakage current display • Programmable persistent fault time and reclaim time • Leakage fault current recording • Remote reset function • Programmable lockout auto reset time • Standard DIN 96x96mm panel mounting • Incorporated positive safety feature into trip contact TYPICAL APPLICATION DIAGRAM N AUX L1 L2 L3 N REMOTE RESET L PE MIKRO ZCT MK330A 1 2 3 4 5 TRIP SAFE CONTACT* NC 9 NO 10 6 8 7 CONTACTOR The EARTH wire must not pass through the ZCT PROGRAMMABLE CONTACT NC COM 11 12 13 14 NO 15 COM 16 LOAD * The trip safe contact is activated (terminal 10-11 closed) when the relay is in normal power-up condition with the measured leakage current less than 0.85 IΔn. MK330A Self-Reclosing Earth Leakage Relay • Protected against nuisance tripping Technical Data CASE DIMENSIONS AUXILIARY SUPPLY PERFORMANCE :184~276VAC :94~127VAC :50Hz :3VA typical Setting accuracy Timing accuracy 96 mm : -15% to +0% : ±5% 96 mm Model MK330A-230A Model MK330A-110A Rated frequency VA rating Front Sensitivity adjustment :30mA, 50mA, 0.10~1.00A (Step=50mA) 1.00~10.0A (Step=1.00A) Time delay adjustment :Instantaneous, 0.1~3.0sec (Step=0.1s) Number of shots :0~30 (Step=1, 0=Disable auto re-close function) Dead time :1~500sec (Step=1sec) Persistent fault time :0~500sec (Step=1sec, 0=Disable function) Reclaim time :0~500min (Step=1min, 0=Disable function) Lockout auto reset time :0~200hour (Step=1Hr, 0=Disable function) Programmable contact :Option 0 = Disable Option 1 = All (Option 2 to 6) Option 2 = ZCT error Option 3 = Leakage trip, test trip, re-close lockout Option 4 = Re-close lockout Option 5 = Pre-fault alarm, leakage trip, test trip, re-close lockout Option 6 = Re-close lockout, ZCT error 90 mm 70 mm Side 91.0 ± 0.5 mm Panel Cutout RECORD Fault record Storage :3 latest tripped fault currents or “tSt” for manual test trip :Non-volatile memory INPUT Remote reset :N.O. dry contact OUTPUTS Trip safe contact :Activated when the relay is in normal power-up condition with the measured leakage current less than 0.85 IΔn. Programmable contact :Activated according to user setting CONTACTS Contact arrangement Contact rating Expected electrical life Expected mechanical life :Change-over :5A (NO) / 3A (NC) / 250V AC1 :10,000 at rated current :5 x 106 operations INDICATORS Pre-fault alarm Time delay Leakage trip Re-close lockout ZCT connection error Real-time leakage current :Red indicator (Normal blink) :Red indicator (Fast blink) :7-segment display and red indicator :7-segment display and red indicator :7-segment display and red indicator :7-segment display ZERO-PHASE CURRENT TRANSFORMER To operate with Mikro’s ZCT series of current transformers MECHANICAL Mounting method Front panel Approximate weight 91.0 ± 0.5 mm MK330A Self-Reclosing Earth Leakage Relay SETTING :Panel mount :Standard DIN 96x96mm :0.58kg (excluding ZCT) Ordering Information MODEL DESCRIPTION MK330A-230A For 50Hz system, auxiliary voltage 184~276VAC MK330A-110A For 50Hz system, auxiliary voltage 94~127VAC MK301A / 302A / 301E Features MK301A Features for MK302A only • Trip starting indicator • Safety output contact • Detection of no connection to current • Earth leakage level indicators transformer for extra safety • Remote reset and remote test functions • Relay tripped indicator • High immunity to electrical interference TYPICAL APPLICATION DIAGRAMS AUX N MK301A or MK302A PE LOAD NC 1 MK302A 2 NO 3 COM 4 5 6 7 SHUNT TRIP TRIP CONTACT 9 10 11 12 13 The EARTH wire must not pass through the ZCT 8 14 15 16 L1 L2 L3 N L AUX N MK302A PE LOAD NO MK301E 1 2 3 NC COM COM NC 4 5 6 7 NO The EARTH wire must not pass through the ZCT 8 TRIP CONTACT SAFETY CONTACT* 9 10 11 12 13 14 15 16 CONTACTOR REMOTE RESET* L AUX L1 L2 L3 N REMOTE TEST* N MK301E PE LOAD NC 1 2 3 NO 4 COM 5 6 7 8 SHUNT TRIP TRIP CONTACT TRIP CONTACT 2** 9 10 11 12 13 14 ** Applicable to MK301E series only 16 L1 L2 L3 N * Applicable to MK302A series only 15 The EARTH wire must not pass through the ZCT MK301A / 302A / 301E Earth Leakage Relay L Technical Data CASE DIMENSIONS Model MK301A / 302A -240A Model MK301A / 302A -110A Rated frequency VA rating : 198 ~ 265 V AC : 94 ~ 127 V AC : 50 / 60 Hz : 3 VA typical 96 mm AUXILIARY SUPPLY 96 mm 90 mm 70 mm Front Side SETTING RANGES Sensitivity adjustment Delay time adjustment : 0.03 A to 30 A : 0 sec to 3.0 sec 91.0 ± 0.5 mm Setting accuracy Timing accuracy :-15% to +0% :±5% MK301A / 302A / 301E Earth Leakage Relay CONTACTS Contact arrangement Contacts rating Contact material Expected electrical life Expected mechanical life :1 x manual reset type :1 x safety contact* :NC and NO contacts available :5 A, 250 V AC ( cosϕ = 1) contact rating :Silver alloy :100,000 operations at rated current :5 x 106 operations INPUTS Remote Test* / Reset Inputs* :N.O. dry contact INDICATORS Auxiliary supply Time delay Trip Real-time leakage current :Green indicator : Red indicator :Red indicator :Red indicator ZERO - PHASE CURRENT TRANSFORMER To operate with Mikro’s ZCT series of current transformer MECHANICAL Mounting method Front panel Approximate weight :Panel mounting :Standard DIN 96mm x 96mm :0.6 kg ( excluding ZCT ) ENVIRONMENTAL CONDITIONS Temperature Humidity :-5˚C to +55˚C :56 days at 93% RH and 40˚C non-condensing * Applicable to MK302A series only ** Applicable to MK301E series only Ordering Information MODEL DESCRIPTION MK301A - 240A MK301A - 110A MK302A - 240A MK302A -110A MK301E - 240A MK301E -110A For 50 / 60 Hz system, auxiliary voltage 198 ~ 265 V AC For 50 / 60 Hz system, auxiliary voltage 94 ~ 127 V AC For 50 / 60 Hz system, auxiliary voltage 198 ~ 265 V AC For 50 / 60 Hz system, auxiliary voltage 94 ~ 127 V AC For 50 / 60 Hz system, auxiliary voltage 198 ~ 265 V AC For 50 / 60 Hz system, auxiliary voltage 94 ~ 127 V AC Panel Cutout 91.0 ± 0.5 mm PERFORMANCE DIN330 Features • Detection of no connection to ZCT • Numerical self reclosing earth leakage relay • Relay trip indicator • Programmable current sensitivity and time delay • Relay alarm indicator • Programmable persistent fault time and reclaim time • Programmable lockout auto reset time • Incorporated positive safety feature into trip contact • Real-time leakage current display • Leakage fault current recording • Remote reset function • Standard DIN rail mounting • Protection against nuisance tripping • Standard 35mm DIN rail mounting • One programmable contact for flexibility TYPICAL APPLICATION DIAGRAM AUX N PE L1 L2 L3 N L REMOTE RESET MIKRO ZCT DIN330 1 2 3 4 TRIP SAFE CONTACT 8 9 10 COM NO 11 5 6 7 CONTACTOR PROGRAMMABLE CONTACT 13 14 NC COM NO 12 NC LOAD * The trip safe contact is activated (terminal 9-10 closed) when the relay is in normal power-up condition with the measured leakage current less than 0.85 IDn. The EARTH wire must not pass through the ZCT DIN330 Earth Leakage Relay • Programmable dead time and number of shots Technical Data CASE DIMENSIONS AUXILIARY SUPPLY Model DIN330-240 A(6) Rated frequency VA rating PERFORMANCE :198 ~ 265 V AC : 50 or 60 Hz :3 VA typical Setting accuracy Timing accuracy 71 mm : -15% to +0% : ±5% 20 mm 45 mm SETTINGS DIN330 Earth Leakage Relay 20 mm 70 mm CONTACTS Contact arrangement Contact rating Expected electrical life Expected mechanical life Ordering Information : 3 latest tripped fault currents or “tSt” for manual test trip : Non-volatile memory INPUTS Remote reset : N.O. dry contact OUTPUTS Trip safe contact :Activated when the relay is in normal power-up condition with the measured leakage current less than 0.85 IDn. Programmable contact :Activated according to user setting INDICATORS 50% pre-fault alarm Time delay Leakage trip Reclose lockout ZCT fault Real time leakage current :Red indicator (Normal blink) :Red indicator (Fast blink) :7-segment display and red indicator :7-segment display and red indicator :7-segment display and red indicator : 7-segment display ZERO-PHASE CURRENT TRANSFORMER To operate with Mikro’s ZCT series of current transformer MECHANICAL Mounting method Approximate weight : Standard 35 mm din rail mounting : 0.38 kg (Excluding ZCT) ENVIRONMENTAL CONDITIONS Temperature Humidity Side 30 mm 20 mm 20 mm :Change-over :5A (NO) / 3A (NC) / 250 V AC1 :10,000 operations at rated current :5 x 106 operations RECORD Fault record Storage Front 85 mm Sensitivity adjustment : 30 mA, 50 mA, 0.10 A –1.00 A (Step = 50 mA), 1.00 A – 10.0 A (Step = 1.00 A) Time delay adjustment : Instantaneous, 0.1s – 3.0s. Step = 0.10 sec. Number of shots :0 - 30. Step = 1. 0 = Disable auto reclose function Dead time :1 - 500 sec. Step = 1 sec. Permanent fault time :0 - 500 sec. Step = 1 sec. 0 = Disable function Reclaim time :0 - 500 minute. Step = 1 min. 0 = Disable function Lockout auto reset time :0 - 200 hour. Step = 1 Hrs. 0 = Disable function Programmable contact :Option 0 = Disable Option 1 = All (Option 2 to 6) Option 2 = ZCT error Option 3 = Leakage trip, test trip, re-close lockout Option 4 = Re-close lockout Option 5 = Pre-fault alarm, leakage trip, test trip, reclose lockout Option 6 = Re-close lockout, ZCT error :-5˚C to +55˚C :56 days at 93% RH and 40˚C non-condensing MODEL DESCRIPTION DIN330 - 240 A DIN330 - 240 A6 For 50 Hz system, auxiliary voltage 240 V AC For 60 Hz system, auxiliary voltage 240 V AC DIN310 / 310E Features Features For DIN310E only • Numerical earth leakage relay • Positive safety output contact • Programmable current sensitivity and time delay • 50% pre-fault output contact • Detection of no connection to ZCT • Remote reset function • Relay trip indicator • Relay alarm indicator • Real-time leakage current display • Leakage fault current recording • 50% pre-fault indicator • Standard DIN rail mounting TYPICAL APPLICATION DIAGRAMS DIN310 AUX PE L1 L2 L3 N L N MIKRO ZCT The EARTH wire must not pass through the ZCT DIN310 1 2 3 4 5 6 7 13 14 SHUNT TRIP TRIP CONTACT 8 9 10 11 COM NO 12 NC LOAD L AUX N PE L1 L2 L3 N DIN310E REMOTE RESET MIKRO ZCT DIN310E 1 ALARM CONTACT 8 2 3 4 TRIP CONTACT 9 10 COM NO 5 6 7 CONTACTOR SAFETY CONTACT 11 12 NC COM NO 13 14 NC LOAD The EARTH wire must not pass through the ZCT DIN310 / 310E Earth Leakage Relay • Protection against nuisance tripping Technical Data CASE DIMENSIONS :198 ~ 265 V AC :198 ~ 265 V AC : 50 or 60 Hz :3 VA typical Setting accuracy Timing accuracy : -15% to +0% : ±5% 20 mm 45 mm DIN310-240 A(6) DIN310E-240 A(6) Rated frequency VA rating 71 mm PERFORMANCE AUXILIARY SUPPLY SETTING RANGES Sensitivity adjustment : Time delay adjustment : 30 mA, 50 mA, 0.10 A –1.00 A (Step = 50 mA), 1.00 A – 10.0 A (Step = 1.00 A) Instantaneous, 0.1s – 3.0s. Step = 0.10 sec. Front 20 mm CONTACTS Contact arrangement Contact rating Expected electrical life Expected mechanical life Earth Leakage Relay DIN310 / 310E : 3 latest tripped fault currents or “tSt” for manual test trip : Non-volatile memory 85 mm RECORD Fault record Storage 70 mm :Change-over :5A (NO) / 3A (NC) / 250 V AC1 : 10,000 operations at rated current : 5 x 106 operations INPUT Remote reset* Side 30 mm 20 mm 20 mm : N.O. dry contact OUTPUTS Trip Contact Positive safety contact* Pre-fault alarm contact* :Activated if relay tripped or ZCT fault :Activated when ZCT is connected properly to the relay :Activated when leakage current exceeded 50% of sensitivity setting INDICATORS 50% pre-fault alarm Time delay Leakage trip ZCT fault Real time leakage current :Red indicator :Red indicator :7-segment display and red indicator :7-segment display and red indicator : 7-segment display ZERO-PHASE CURRENT TRANSFORMER To operate with Mikro’s ZCT series of current transformer MECHANICAL Mounting method Approximate weight : Standard 35 mm DIN rail mounting : 0.38 kg (Excluding ZCT) ENVIRONMENTAL CONDITIONS Temperature Humidity * Applicable to DIN310E series only :-5˚C to +55˚C :56 days at 93% RH and 40˚C non-condensing Ordering Information MODEL DESCRIPTION DIN310 - 240 A DIN310E - 240 A DIN310 - 240 A6 DIN310E - 240 A6 For 50 Hz system, auxiliary voltage 240 V AC For 50 Hz system, auxiliary voltage 240 V AC For 60 Hz system, auxiliary voltage 240 V AC For 60 Hz system, auxiliary voltage 240 V AC DIN300 / 300E Features Features For DIN300E only • 25 selectable sensitivity settings: 30 mA to 30 A • 50% pre-fault output contact • Remote test and remote reset functions • 9 selectable time delays: 0ms to 3s • Earth leakage level indicators • Detection of no connection to ZCT • Relay tripped indicator • Trip starting indicator • Protected against nuisance tripping DIN300 PE L1 L2 L3 N N S1 The EARTH wire must not pass through the ZCT S2 1 2 3 4 5 6 7 SHUNT TRIP TRIP CONTACT 8 9 10 11 12 COM 13 NO DIN300 / 300E AUX L 14 NC 1 N 2 3 4 50% PRE-FAULT CONTACT 8 9 COM 10 NO 11 PE L1 L2 L3 N AUX REMOTE TEST L REMOTE RESET LOAD DIN300E S1 The EARTH wire must not pass through the ZCT S2 5 6 7 SHUNT TRIP TRIP CONTACT 12 NC COM 13 NO 14 NC LOAD Earth Leakage Relay TYPICAL APPLICATION DIAGRAMS Technical Data CASE DIMENSIONS 71mm AUXILIARY SUPPLY : 198 ~ 265 V AC : 94 ~ 127 V AC : 50 / 60 Hz : 3 VA typical 20mm 45mm Model DIN300 / 300E -240A Model DIN300 / 300E -110A Rated frequency VA rating SETTINGS RANGES Sensitivity setting Time delay setting : 30 mA, 50 mA, 75 mA, 100 mA, 125 mA, 150 mA, 200 mA, 250 mA, 300 mA, 500 mA, 750 mA, 1A, 1.25A, 1.5A, 2A, 2.5A, 3A, 5A, 7.5A, 10A, 12.5 A, 15A, 20A, 25A, 30A. : Instantaneous, 50 ms, 100 ms, 150 ms, 250 ms, 350 ms, 500 ms, 1s, 3 s. 20mm Front view PERFORMANCE Setting accuracy Timing accuracy 71mm :-15% to +0% :±5% Earth Leakage Relay DIN300 / 300E Contacts ( Trip / 50% pre-fault* ) Contact arrangement : Contact rating : Contact material : Expected electrical life : Expected mechanical life : Change over 5 A, 250 V AC ( cosϕ = 1 ) Silver alloy 100,000 operations at rated current 5 x 106 operations Side view 85mm CONTACTS 30mm 20mm 20mm INPUTS Remote test* / Reset inputs* : N.O. dry contacts ZERO - PHASE CURRENT TRANSFORMER To operate with Mikro’s ZCT series of current transformer INDICATORS Auxiliary supply Time delay Trip Leakage current* : : : : Green indicator Red indicator Red indicator 5 red indicators for leakage levels MECHANICAL Mounting method Approximate weight : Din rail mounted : 0.3 kg ENVIRONMENTAL CONDITIONS Temperature Humidity * Applicable to DIN300E model only :-5˚C to +55˚C :56 days at 93% RH and 40˚C non-condensing Ordering Information MODEL DESCRIPTION DIN300 - 240 A For 50 / 60 Hz system, auxiliary voltage 240 V AC DIN300 - 110 A For 50 / 60 Hz system, auxiliary voltage 110 V AC DIN300E - 240 A For 50 / 60 Hz system, auxiliary voltage 240 V AC DIN300E - 110 A For 50 / 60 Hz system, auxiliary voltage 110 V AC ZCT40S/60S/80S/120S CASE DIMENSIONS Front C A 40S B 60S D G E H G D H F F 40S / 60S / 80S Bottom 120S Bottom DIMENSION (mm) Model ZCT40S ZCT60S ZCT80S 80S A B C D E F G H 40 78 97 3.5 36 52 16 17.5 Ordering Information 120S MODEL DESCRIPTION ZCT40S ZCT60S ZCT80S ZCT120S 40mm inner diameter 60mm inner diameter 80mm inner diameter 120mm inner diameter 60 95 110 6 31.5 62 20.5 11 80 120 135 3.5 36 94 16 17.5 ZCT120S 120 180.5 179.5 6 37 147 20.5 16 ZCT 40S / 60S / 80S / 120S Zero-Phase Current Transformer B DVM Features Technical Data • Built-in selector switch Auxiliary supply VA rating Input frequency Maximum input voltage • Easy-to-read, 14.2mm digit display • DIN size casing : 198 ~ 265 V AC : 94 ~ 127 V AC : 3 VA : 47 ~ 66 Hz : 500 Vrms TYPICAL APPLICATION DIAGRAM DVM360 Series DVM100 Series R LINE Y B 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 Aux Supply AC 240 V Aux Supply AC 240 V 91.5 mm 96 mm Front 87 mm 91.0 ± 0.5 mm Side Panel Cutout Ordering Information MODEL DESCRIPTION DVM360 - 240A DVM100 - 240A DVM360 - 110A DVM100 - 110A Auxiliary voltage 240 V AC Auxiliary voltage 240 V AC Auxiliary voltage 110 V AC Auxiliary voltage 110 V AC 91.0 ± 0.5 mm CASE DIMENSIONS 96 mm DVM Digital AC Voltmeter N DAM Features Technical Data • Built-in selector switch Auxiliary supply VA rating Input frequency Maximum input Ammeter CT ratio Class • Easy-to-read, 14.2mm digit display • DIN size casing • Wide selection of current transformer (CT) ratio : 198 ~ 265 V AC : 94 ~ 127 V AC : 3 VA : 47 ~ 66 Hz : 6 A continuous : .../5 A : 1.0 TYPICAL APPLICATION DIAGRAM DAM100 / 1000 Series DAM330 / 3000 Series LINE R Y 1 2 3 4 5 6 7 8 9 10 11 12 Aux Supply AC 240 V 1 2 3 4 5 6 7 8 9 10 11 12 Aux Supply AC 240 V 91.5 mm 96 mm 96 mm Front 87 mm 91.0 ± 0.5 mm Side Panel Cutout 91.0 ± 0.5 mm CASE DIMENSIONS DAM Digital AC Ammeter B Ordering Information MODEL /SERIES WITH SELECTOR WITHOUT SELECTOR UNIT DAM330 A DAM3000 A DAM100 A DAM1000 A For primary current from 60 A to 500 A For primary current from 600 A to 5000 A DAM 330 - XXXX DAM 100 - XXXX DAM 3000 - XXXX DAM 1000 - XXXX Order number Order number Model DAM 330 & DAM 100 ORDER NUMBER DAM Digital AC Ammeter DISPLAY FORMAT *CT RATIO Model DAM3000 & DAM1000 ORDER NUMBER *CT RATIO 0060 60 / 5 A 600 600 / 5 A 0100 100 / 5 A 800 800 / 5 A 0150 150 / 5 A 1000 1000 / 5 A 0200 200 / 5 A 1200 1200 / 5 A 0250 250 / 5 A 1500 1500 / 5 A 0300 300 / 5 A 1600 1600 / 5 A 0400 400 / 5 A 2000 2000 / 5 A 0500 500 / 5 A 2400 2400 / 5 A 2500 2500 / 5 A 3000 3000 / 5 A 3200 3200 / 5 A 3500 3500 / 5 A 4000 4000 / 5 A 4500 4500 / 5 A 5000 5000 / 5 A Example: Model DAM 330 - 0060 for digital ammeter with CT ratio 60 / 5 A. *CT : Current Transformer For other CT ratio, please contact the manufacturer. MODEL DESCRIPTION DAM330 - xxxx - 240A Auxiliary voltage 240 V AC DAM100 - xxxx - 240A Auxiliary voltage 240 V AC DAM330 - xxxx - 110A Auxiliary voltage 110 V AC DAM100 - xxxx - 110A Auxiliary voltage 110 V AC DAM3000 - xxxx - 240A Auxiliary voltage 240 V AC DAM1000 - xxxx - 240A Auxiliary voltage 240 V AC DAM3000 - xxxx - 110A Auxiliary voltage 110 V AC DAM1000 - xxxx - 110A Auxiliary voltage 110 V AC MU250 / 150 Product Description MU150 and MU250 are voltage relays that combine various protections and starting delay. MU150 Single-phase MU150 is used for single-phase monitoring while MU250 is used for 3-phase monitoring. Features Features For MU250 only • Microprocessor based numerical relay • 3-Phase • Undervoltage • Unbalance • Overvoltage • Phase loss • Delay-on • Phase sequence • 2 voltage-free output contacts • With or without neutral connection • Voltage and frequency display • Phase to phase or phase to neutral monitoring TYPICAL APPLICATION DIAGRAMS MU250 L1 L2 L3 N (OPTIONAL) 1 2 3 4 R1 8 5 6 7 13 14 R2 9 COM NO 10 11 NC 12 COM NO NC 5 6 7 13 14 MU250 (Neutral connection is optional) MU150 L N 1 2 3 4 R1 8 R2 9 COM NO 10 NC 11 12 COM NO NC MU150 MU250 / 150 Voltage Relay MU250 3-phase Technical Data CASE DIMENSIONS 71 mm SETTING RANGES : : : : : 1% to 25% 0.1s to 30s 1% to 20% 0.1s to 30s 0s to 999s For MU250 only: Unbalance Time delay for unbalance Phase loss Phase sequence : : : : 3% to 20% 0.1s to 30s Fixed time <0.1s Fixed time <0.1s 20 mm 45 mm Undervoltage Time delay for undervoltage Overvoltage Time delay for overvoltage Start time delay Front 20 mm 70 mm POWER SUPPLY INPUT 85 mm Input voltage : MU150: 220V(-25%) to 240V(+20%) AC (Phase-Neutral) : MU250: 380V(-25%) to 415V(+20%) AC (Phase-Phase) Supply frequency : 45Hz to 65Hz Maximum power consumption: MU250: 3VA : MU150: 2.5VA Side CONTACTS Contact arrangement Contact rating Contact material Expected electrical life Expected mechanical life : : : : : Change-over 5A, 250V AC (cos j=1) Silver alloy 100,000 operations at rated current 5 X 106 operations Ordering Information MU250 / 150 Voltage Relay INDICATORS Auxiliary supply Pickup indicator Trip : Green LED indicator : Red LED indicator : 7-segment display and red LED indicators MECHANICAL Mounting Approximate weight 30 mm 20 mm 20 mm : Din rail mounted : MU150: 0.27kg : MU250: 0.31kg ACCURACY Protection thresholds Time delay Measurements : : : : ± 3% 0 to 0.5s, ± 15% with minimum 40ms 0.6s and above, < ± 3% ± 3% Temperature Humidity : -5 C to +55 C : 56 days at 93% RH and 40 C non-condensing ENVIRONMENTAL CONDITIONS MODEL DESCRIPTION MU150-240V Single-Phase, 220/230/240 V AC, 45-65 Hz power supply MU250-415V 3-Phase, 380/400/415 V AC, 45-65 Hz power supply MU2300 Introduction Technical Data The MU2300 is a microprocessor based numerical relay for voltage protection functions in electrical distribution network. INPUTS Measuring input: Features Rated voltage input Rated frequency :57-130 V :50 / 60 Hz Rated auxiliary voltage: • Multifunction numerical voltage protection relay Model MU2300-150D Model MU2300-240AD • Low-set undervoltage stage (U<) with definite-time or inverse-time characteristic : 24~150 V DC : 85~265 V AC 110~340 V DC Power consumption: Binary Input: External binary input • High-set overvoltage stage (U>>) with definite-time • Negative sequence overvoltage protection (U2>) with definite-time or inverse-time characteristic • Neutral displacement / residual overvoltage protection (U0>)with definitetime or inverse-time characteristic :85~265 V AC/DC OUTPUTS 5 programmable contacts +1 IRF contact: Rated voltage Continuous carry Make and carry for 0.2 s : 250 V AC/DC :5A : 30 A Contact specification: Expected electrical life : 105 operations Expected mechanical life : 5 x 106 operations UNDER-VOLTAGE ELEMENT • Multi-function isolated digital input with wide input voltage range Low set setting U< :5 - 130 V High set setting U<< :5 - 130 V Time multiplier, TMS :0.5 - 100 Low set Definite time tU< :0 - 600 s High set Definite time tU<<:0 - 600 s • Fault record and event code recording OVER-VOLTAGE ELEMENT • Five programmable voltage-free output contacts Low set setting U> :5 - 200 V High set setting U>> :5 - 260 V Time multiplier, TMS :0.5 - 100 Low set definite time tU> :0 - 600 s High set definite time tU>>:0 - 600 s • Can be used in single-phase or threephase operation • Isolated RS485 Modbus - RTU communication NEGATIVE SEQUENCE OVER-VOLTAGE ELEMENT Negative sequence over-voltage setting, U2> : 5 - 200 V Time multiplier, TMS : 0.5 - 100 Negative sequence over-voltage definite time tU2> : 0 - 600 s COMMUNICATION RS485 Modbus - RTU ENVIRONMENTAL CONDITIONS Temperature Humidity RESIDUAL OVER-VOLTAGE ELEMENT Residual over-voltage setting, U0> Time multiplier, TMS Residual over-voltage definite time tU0> : 0.5 - 130 V : 0.5 - 100 : 0 - 600 s : -5˚C to +55˚C : 56 days at 93% RH and 40˚C non-condensing Overvoltage & Undervoltage Relay • Low-set overvoltage stage (U>) with definite-time or inverse-time characteristic : 6 ~ 10 VA typical : 5 ~ 9 W typical MU2300 • High-set undervoltage stage (U<<) with definite-time AC auxiliary voltage DC auxiliary voltage UNDERVOLTAGE CHARACTERISTIC CASE DIMENSIONS OVERVOLTAGE CHARACTERISTIC 10 TMS=8 TMS= 10 5 TMS= 3 TMS= 142 mm 10 165 mm 100 Operating time (sec) Operating time (sec) 100 1 TMS=10 TMS=8 TMS=5 TMS=3 0.1 Front TMS=1 1 0 1 TMS= 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.01 Applied voltage/relay setting voltage 0 2 4 6 8 10 12 14 16 18 20 Applied voltage/relay setting voltage 198 mm 34 mm A B C 2 3 5 6 8 9 12 13 External Digital 14 Input Uaux A 32 33 31 C 2 38 37 R2 5 3 6 40 39 R3 8 9 42 41 R4 11 27 26 R5 12 28 Internal 30 Relay 29 Failure 22 13 External Digital 14 Input Termination Resistor 23 N- A 24 P+ 25 Uaux Communication Cable Shield B 38 37 R2 40 39 R3 129 1 mm 42 41 R4 27 26 R5 28 Internal 30 Relay 29 Failure 22 Panel Cutout Termination Resistor 23 N- 24 P+ 25 Communication Cable Shield B 2Vp-p + Vresidual connection A B C 3 5 6 8 9 11 12 13 External Digital Input 14 Uaux Ordering Information A B C 2 32 33 31 C 34 Trip Contact 36 R1 35 Phase rotation 3Vp-p + Vresidual connection A 32 33 31 C Phase rotation MU2300 Overvoltage & Undervoltage Relay 11 34 Trip Contact 36 R1 35 Side 139 1 mm A B C 136 mm TYPICAL APPLICATION DIAGRAMS 34 Trip Contact 36 R1 35 2 38 37 R2 5 3 6 40 39 R3 8 9 42 41 R4 11 27 26 R5 12 28 Internal 30 Relay 29 Failure 22 13 External Digital 14 Input Termination Resistor 23 N- A 24 P+ 25 B Phase rotation 3Vp-n + Vresidual connection Uaux Communication Cable Shield 32 33 31 C B Phase rotation 3Vp-n connection 34 Trip Contact 36 R1 35 38 37 R2 40 39 R3 42 41 R4 27 26 R5 28 Internal 30 Relay 29 Failure 22 Termination Resistor 23 N- 24 P+ 25 Communication Cable Shield MODEL DESCRIPTION MU2300-150D For 50 / 60 Hz system, auxiliary voltage 24 ~ 150 V DC MU2300-240AD For 50 / 60 Hz system, auxiliary voltage 85 ~ 265 V AC or 110~340 V DC RPR415 Features Product Description • Reverse power monitoring The RPR 415 relay is a directionally controlled timing relay used to protect AC generators from motoring. When such a condition occurs and the reverse current exceeded the customer adjustable preset limit and the current persists for a predetermined delay time, the trip relay operates to diconnect the circuit. • 3-phase-4-wire system • Adjustable reverse power setting • Adjustable tripping time delay • Indicators for auxiliary power, trip delay and trip status • Test button Technical Data INPUT TYPICAL APPLICATION DIAGRAM DIRECTION OF CURRENT FOR OPERATION L1 P1 S1 L2 Rated voltage (U n) : 380/440 V AC Rated current (I n) : 5 A Rated frequency : 50 Hz / 60 Hz Overload : 1.2 x U n, 2 x I n continuous 1.2 x U n, 10 x I n for 3 sec OUTPUT L3 N 1 2 3 COM NC 9 10 11 4 5 6 7 8 13 14 15 16 Contact Arrangement:Change-over Contact rating :5 A, 250 V AC ( cosϕ = 1 ) Contact material :Silver alloy Expected electrical life: 100,000 operations at rated current Expected mechanical life: 5 x 106 operations NO 12 SETPOINT : : : : 2% to 20% reverse current Adjustable 0 sec to 20 sec 1% 0.5% ENVIRONMENTAL CONDITIONS Temperature : -5˚C to +55˚C Humidity : 56 days at 93% RH and 40˚C non-condensing 142 mm 96 mm 96 mm Front 132 mm 91.0 ± 0.5 mm Side Panel Cutout Ordering Information MODEL DESCRIPTION RPR415 Auxiliary voltage 415 V AC 91.0 ± 0.5 mm CASE DIMENSIONS RPR415 Reverse Power Relay Range Time delay Hysteresis Repeatability Front Panel Description 1 11% 6.6% 2% 15.5% 5s 20% % 10s 15s 3 0s 20s DELAY 5 TEST 2 RESET 4 Front Panel Description 1. Light Indicators Indicator AUX Indicator DELAY Indicator TRIP OFF OFF OFF No auxiliary power supply. ON OFF OFF System normal mode. No tripping. ON ON OFF Status Reverse current exceeded pre-set limit. Time delay countdown started. ON OFF ON System tripped. 2. Reverse Current Adjustment Knob • For setting the minimum reverse current before tripping • Setting range from 2% to 20% RPR415 Reverse Power Relay 3. Delay Timing Adjustment Knob • Trip time delay setting • Setting range from 0 to 20 sec 4. Test Button • Press the test button to simulate a trip condition. 5. Reset Button • The reset button is for reseting the light indicator after tripping. • To reset, press the reset button once • The tripping contact will be released once the reverse current fall below the pre-set limit. However, the TRIP light indicator is latched. Press the reset button to reset the light indicator to normal state. MX200A/180A/160A Features Product Description • Electronic monitoring relay MX160A, MX180A & MX200A are single or 3-phase monitoring relays. The relays are designed for application where it required to maintain the voltage within set limits. A built-in adjustable time delay prevents nuisance tripping. • Voltage monitoring for single 3-phase system MX200A Under & Over Voltage Relay • Phase failure monitoring • Adjustable voltage limit • Adjustable delay time • Indicators for voltage fault • Indicators for power and output ON WIRING DIAGRAM Over Voltage Relay Single-Phase System 3-Phase System L N L3 L2 L1 N 5 Under Voltage Relay 7 8 3 9 2 MX160A 6 4 1 11 6 5 7 4 8 3 10 9 2 1 11 10 OPERATIONS DIAGRAM i ) Over Voltage Function** Over Voltage Limit Hysteresis R Y B Relay ON T >U LED ON ii ) Under Voltage Function* R Y B Hysteresis Under Voltage Limit Relay ON <U LED ON T MX200A / 180A / 160A 3 - Phase Voltage Control Relay MX180A Technical Data POWER SUPPLY INPUT 3-PHASE SYSTEM Phase-to-phase voltage SINGLE PHASE Phase-to-neutral voltage Frequency range Max. power consumption Input connections For 3-phase model For single-phase model : 380 V AC ± 20% 400 V AC ± 20% 415 V AC ± 20% : 220 V AC ± 20% 230 V AC ± 20% 240 V AC ± 20% : 45 to 65 Hz : 3 VA : Phase L1, L2, L3 to pin 5, 6, & 7 Neutral to pin 11 : Phase L to pin 5, 6 & 7*** Neutral to pin 11 SETTING RANGES Lower voltage limit * Upper voltage limit ** Delay time, T : 78% - 98% : 102% - 122% : 0.1 - 10s HYSTERESIS ≤1% of rms - value CASE DIMENSIONS MX200A / 180A / 160A 3 - Phase Voltage Control Relay CONTACT OUTPUT Cotact arrangement Contact rating Contact material Expected electrical life Expected mechanical life 80 mm : SPDT change-over contacts. : 5A, 250 V AC ( cosϕ=1) : Silver alloy : 100,000 operations at rated current : 5 x 106 operations 72.5 mm 35 mm INDICATORS Power supply ON Output ON Under voltage limit (U<) * Over voltage limit (U>) ** : Green indicator : Red indicator : Red indicator : Red indicator MECHANICAL Mounting Approximate weight : Circular 11-pin plug-in socket : 0.25kg Ordering Information MODEL FUNCTION Under Over Voltage Voltage Monitoring Monitoring Supply Voltage V AC MX160A - 380 YES NO 380 MX160A - 400 YES NO 400 MX160A - 415 YES NO 415 MX180A - 380 NO YES 380 ** Applicable to MX180A and MX200A only MX180A - 400 NO YES 400 *** For single phase connection, short pin 5,6 & 7 MX180A - 415 NO YES 415 MX200A - 380 YES YES 380 MX200A - 400 YES YES 400 MX200A - 415 YES YES 415 ENVIRONMENTAL CONDITIONS Temperature Humidity : -5˚C to +55˚C : 56 days at 93% RH and 40˚C non-condensing * Applicable to MX160A and MX200A only MX100/50 Features Introduction • Electronic monitoring relay This phase sequence and phase failure relay is designed for application where the 3-phase supply needs to be continuously monitored for proper sequencing and phase loss. Commonly used to protect a 3-phase motor. • Phase sequence monitoring* MX100 Phase Sequence & Phase Failure monitoring • Phase failure monitoring • Plug-in type module • Indicators for power and alarm status WIRING DIAGRAMS Example 2 Example 1 L3 L2 L1 3~ 6 5 L3 L2 L1 N 3~ 4 8 4 Phase Failure monitoring 3 9 3 2 1 11 6 5 7 MX50 8 9 2 10 7 1 11 10 Condition Pin 5 Pin 6 Pin 7 Relay Remark 1 L1 L2 L3 ON System healthy 2 Loss L2 L3 OFF Phase failure 3 L1 Loss L3 OFF Phase failure 4 L1 L2 Loss OFF Phase failure 5 L2 L1 L3 OFF Sequence fault* 6 L3 L2 L1 OFF Sequence fault* * Applicable to MX100 model only MX100 / 50 3-Phase Voltage Sequence/Failure Control Relay FUNCTION TABLE Technical Data CASE DIMENSIONS POWER SUPPLY INPUT Phase-to-phase voltage : 230 V AC ±20% : 400 V AC ±20% Frequency range : 45 to 65 Hz Max power consumption : 3 VA Input connections : Phase L1 to pin 5 Phase L2 to pin 6 Phase L3 to pin 7 Neutral (optional) to pin 11 72.5 mm CONTACT OUTPUT Contact arrangement Contact rating Contact material Expected electrical life Expected mechanical life 80 mm : : : : : 35 mm SPDT change-over contacts 5 A, 250 V AC ( cosϕ = 1 ) Silver alloy 100,000 operations at rated current 5 x 106 operations INDICATORS Power supply ON Output ON : Green indicator : Red indicator MECHANICAL Mounting Approximate weight : Circular plug-in socket : 0.25 kg MX100 / 50 3-Phase Voltage Sequence/Failure Control Relay ENVIRONMENTAL CONDITIONS Temperature Humidity : -5˚C to +55˚C : 56 days at 93% RH and 40˚C non-condensing Ordering Information MODEL DESCRIPTION MX100 - 230 Auxiliary voltage 230 V AC MX100 - 400 Auxiliary voltage 400 V AC MX50 - 230 Auxiliary voltage 230 V AC MX50 - 400 Auxiliary voltage 400 V AC PFR140/120/80/60 Features • Microprocessor based intelligent auto switching control • Last step can be used as alarm/fan output • Automatic C/K and rated step adjustment • Under/over voltage alarm, under/over compensate alarm & high harmonic distortion alarm • Automatic CT polarity correction • User-friendly setting • Display of power factor, current & total harmonic distortion of current • Complies with IEC 61000-6-2 standard • Programmable sensitivity Technical Data RATINGS AUXILIARY POWER SUPPLY CURRENT INPUT Current Supply voltage Operating Limits Consumption Rated frequency Rated current ( In ) : 5 A Operating Limits : 0.05 A to 6.5 A Rated Frequency : 50 Hz or 60 Hz : 220~240 V AC / 380~415 V AC : -15% + 10% : 10 VA max : 50 Hz or 60 Hz RELAY OUTPUT : 6 / 8 / 12 / 14 ( PFR60 / PFR80 / PFR120 / PFR140 ) : NO contacts type : 5 A, 250 V AC ( cosϕ = 1 ) : Silver alloy : 100,000 operations at rated current : 5 x 106 operations : 12 A continuous CONTROL RANGE Power factor setting C/K setting Switching sensitivity Reconnection time for same step THD threshold Switching Program Rated step coefficient : 0.8 inductive - 0.8 capacitive : 0.03 - 1.20 / Automatic : 5 - 600 s/step : 5 - 240 s : 0.20 - 3.00 ( 20% - 300% ) / OFF : Automatic / Automatic Rotate / 4-quadrant / Manual : 0 / 1 / 2 / 3 / 4 / 5 / 6 / 8 / 12 / 16 ( Automatic if C/K set to Auto ) MECHANICAL Mounting Dimension ( h x w x d ) Approximate weight : Panel mounting : 144mm x 144mm x 90mm : 1 kg ENVIRONMENTAL CONDITIONS Temperature Humidity : -5˚C to +55˚C : 56 days at 93% RH and 40˚C non-condensing PFR140 / 120 / 80 / 60 Power Factor Regulator Numbers of outputs Contact arrangement Contact rating Contact material Expected electrical life Expected mechanical life Max current for the common terminals TYPICAL APPLICATION DIAGRAM MAIN N L3 L2 L1 CASE DIMENSIONS 144 mm P2 CURRENT /5A 11 12 13 14 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 AUX VOLTAGE For 220~240 V AC Model Only 144 mm P1 Power Factor Regulator 15 16 17 18 19 20 21 22 23 24 13 AUX VOLTAGE 220~240 V AC 14 380~415 V AC 13 Front FUSE 90 mm 76 mm K14 K13 K2 K1 Side LOAD Panel Cutout 138 mm 138 mm PFR140 / 120 / 80 / 60 Power Factor Regulator Ordering Information MODEL DESCRIPTION PFR60 - 415 - 50 6 Steps, 50 Hzsystem,auxiliary voltage 380~415 V AC PFR80 - 415 - 50 8 Steps, 50 Hzsystem,auxiliary voltage 380~415 V AC PFR120 - 415 - 50 12 Steps, 50 Hzsystem,auxiliary voltage 380~415 V AC PFR140 - 415 - 50 14 Steps, 50 Hzsystem,auxiliary voltage 380~415 V AC PFR60 - 220 - 50 6 Steps, 50 Hzsystem,auxiliary voltage 220~240 V AC PFR80 - 220 - 50 8 Steps, 50 Hzsystem,auxiliary voltage 220~240 V AC PFR120 - 220 - 50 12 Steps, 50 Hzsystem,auxiliary voltage 220~240 V AC PFR140 - 220 - 50 14 Steps, 50 Hzsystem,auxiliary voltage 220~240 V AC PFR60 - 415 - 60 6 Steps, 60 Hzsystem,auxiliary voltage 380~415 V AC PFR80 - 415 - 60 8 Steps, 60 Hzsystem,auxiliary voltage 380~415 V AC PFR120 - 415 - 60 12 Steps, 60 Hzsystem,auxiliary voltage 380~415 V AC PFR140 - 415 - 60 14 Steps, 60 Hzsystem,auxiliary voltage 380~415 V AC PFR60 - 220 - 60 6 Steps, 60 Hzsystem,auxiliary voltage 220~240 V AC PFR80 - 220 - 60 8 Steps, 60 Hzsystem,auxiliary voltage 220~240 V AC PFR120 - 220 - 60 12 Steps, 60 Hzsystem,auxiliary voltage 220~240 V AC PFR140 - 220 - 60 14 Steps, 60 Hzsystem,auxiliary voltage 220~240 V AC PFR96 / PFR96P Features • Microprocessor based intelligent auto switching control • Automatic C/K and rated step adjustment • Automatic CT polarity correction • Display of power factor & current • Programmable sensitivity • Last step can be used as alarm/fan output • Under/over voltage alarm, under/over compensate alarm • User-friendly setting • Complies with IEC 61000-6-2 standard For PFR96 For PFR96P • For single-phase system • For 3-phase system Technical Data RATINGS AUXILIARY POWER SUPPLY CURRENT INPUT Model PFR96 Model PFR96P Operating Limits Consumption Rated frequency Rated current ( In ) Operating Limits Rated frequency : 110 ~ 120 V AC / 220 ~ 240 V AC : 380 ~ 415 V AC : -15% + 10% : 10 VA max : 50 Hz or 60 Hz :5A : 0.15 A to 6.5 A : 50 Hz or 60 Hz CONTROL RANGE Power factor setting C/K setting Switching sensitivity Reconnection time for same step Switching Program Rated step coefficient : 0.8 inductive - 0.8 capacitive : 0.03 - 1.20 / Automatic : 5 - 600 s/step : 5 - 240 s : Automatic / Automatic Rotate / 4-quadrant / Manual : 0 / 1 / 2 / 3 / 4 / 5 / 6 / 8 / 12 / 16 ( Automatic if C/K set to Auto ) MECHANICAL Mounting : Panel mounting Dimension ( h x w x d ) : 96mm x 96mm x 70mm Approximate weight : 0.6 kg ENVIRONMENTAL CONDITIONS Temperature Humidity : -5˚C to +55˚C : 56 days at 93% RH and 40˚C non-condensing PFR96 / PFR96P Numbers of outputs :6 Contact arrangement : NO contacts type Contact rating : 5 A, 250 V AC ( cosϕ = 1 ) Contact material : Silver alloy Expected electrical life : 100,000 operations at rated current Expected mechanical life : 5 x 106 operations Max current for the common terminals : 12 A continuous Power Factor Regulator RELAY OUTPUT TYPICAL APPLICATION DIAGRAM Diagram 1 - For model PFR96 Diagram 2 - For model PFR96P MAIN N L3 L2 L1 MAIN N L3 L2 L1 6 5 6 VOLTAGE 220 V AC / 110 V AC 4 P1 3 2 P2 Power Factor Regulator 7 5 4 3 2 CURRENT /5A 1 16 7 14 6 13 5 12 4 11 P1 3 10 2 P2 9 1 8 FUSE 15 FUSE 16 6 VOLTAGE 380~415 V AC CURRENT /5A Power Factor Regulator 8 FUSE 15 5 14 4 13 3 12 2 11 1 10 9 1 FUSE K5 K1 LOAD K6 K5 K1 K6 LOAD DESCRIPTION PFR96 - 220 - 50 6 Steps, for 50 Hz system, auxiliary voltage 220~240 V AC PFR96 - 220 - 60 6 Steps, for 60 Hz system, auxiliary voltage 220~240 V AC PFR96 - 110 - 50 6 Steps, for 50 Hz system, auxiliary voltage 110~120 V AC PFR96 - 110 - 60 6 Steps, for 60 Hz system, auxiliary voltage 110~120 V AC PFR96P - 415 - 50 6 Steps, for 50 Hz system, auxiliary voltage 380~415 V AC PFR96P - 415 - 60 6 Steps, for 60 Hz system, auxiliary voltage 380~415 V AC CASE DIMENSIONS 96 mm 96mm MODEL Front 90 mm 70 mm Side 91.0 ± 0.5 mm Panel Cutout 91.0 ± 0.5 mm PFR96 / PFR96P Power Factor Regulator Ordering Information AN112/120 Programmable Alarm Annunciator The AN112/120 series Alarm Annunciator provides ideal solution for all your alarm system management and requirement. It comes with either 12 or 20 windows, and due to the use of microprocessor-based design, the alarm annunciator is highly flexible in terms of functionality and programmability, suitable for all application and industries. Features • 12 or 20 windows. Replaceable super-bright LED modules, with choice of amber or red illumination • 11 Alarm Sequences as per ISA-18.1 standard • Each channel/window fully field programmable, either from front panel built-in pushbutton or using PC • Option of either RS232 or RS485 MODBUS-RTU communication. Comes with user-friendly configuration software. • Repeat relay for each window as well as numerous configurable multifunction output relays for connection to external equipment to form alarm management system • Sleep or unattended mode feature is available, for stations not permanently manned • Auto-silence and auto-acknowledge features, with delay settable from 1 – 255 s TYPICAL CONNECTION DIAGRAM 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 C12 C11 C10 C8 C7 C6 C5 C4 C9 - + - + - + - + - + - + - + D- D+ Sleep 1 2 RS232 RS485 1 2 3 4 Mute Ack Button 1 2 3 1 2 3 4 5 6 7 RBCK SSP AUX3 AUX2 AUX1 Relay output 1 2 3 4 5 6 7 8 9 10 C1 C2 C3 1 2 3 4 1 2 3 4 1 2 3 4 Tests And Standards Electrostatic discharge IEC61000-4-2, Class III, air discharge Electrostatic discharge IEC61000-4-2, Class III, contact discharge Electrical fast transient IEC61000-4-4 Surge immunity IEC61000-4-5 Enclosure protection when panel mounted 8 KV 6 KV 4 KV, 5/50ns 4 KV, L to E Front: IP41 Enclosure: IP30 Alarm Annunciator Power AN112 / 120 Reset Test 1Rst Dis - + Power Ground - + - + - + - + - + + - Technical Data CASE DIMENSIONS WINDOW 50 x 30 mm. White translucent lens. Red, Amber. Coloured by field replaceable LED module. Fast: 1.4 Hz ( 0.4s on, 0.4s off ), Slow: 0.45 Hz ( 1.1s on, 1.1s off ), Intermittent: ( 0.4s on, 1.8s off ) ALARM SEQUENCES M, A, R, R-12, F1A, F1M, F2A, F2M, F3A, F3M, Follower TYPE OF MOUNTING Panel Mounting 237 mm 217 mm Window Dimension: Type: Colours: Windows Flash AN120 Front AUXILIARY POWER INPUT Fuse protected. AN1xx-30 AN1xx-110 Power consumption 132 mm 24-36 V DC or 18-27 V AC. 88-132 V DC or 64-95 V AC. AN112: 6 W, AN120: 8 W 186 mm ALARM CONTACT INPUTS Opto-isolated inputs AN1xx-30 AN1xx-110 Input current 24-36 V DC or 18-27 V AC. 88-132 V DC or 64-95 V AC. 3 mA typical AN120 Side RELAY OUTPUTS Repeat relays AUX1-AUX3, RBACK, SSP Potential free for each alarm point. 5 A at 250 V AC, 3 A at 30 V DC. Resistive load. 237 mm 5 A at 250 V AC, 5 A at 30 V DC. Resistive load. Wire size 28-14 AWG. ( 0.08mm2 to 2.5mm2 ) Removable screw type terminal block ( removable ) 157 mm TERMINALS ENVIRONMENT Operation temperature Storage temperature Humidity -20 to 60˚C -20 to 80˚C 0 - 95% RH, non condensing AN112 Front 132 mm AN112 / 120 Hardware interface AN1xx - xx - x - A: RS232 AN1xx - xx - x - B: Isolated RS485 Protocol Baud rate Modbus - RTU 300 to 57600 126 mm AN112 Side ENVIRONMENTAL CONDITIONS Temperature Humidity : -5˚C to +55˚C : 56 days at 93% RH and 40˚C non-condensing 1.5 mm Ordering Information Order code: AN1 - - - A: RS 232 communication B: RS 485 communication 0: without repeat relays 1: with repeat relays Power Supply: 30, 110 V DC Number of Windows: 12, 20 For example: 12 windows, 30 V DC, with repeat relays, RS232 communication: AN112-30-1-A 132 mm Alarm Annunciator COMMUNICATION 206 mm Bottom