® Industrial controllers 1/160 Double-handle controller D 64 / DD 64 2011 The double-handle controller is a rugged switching device according IEC/EN 60947-5-1 for hoisting applications. The modular design enables the switching device to be used universally. The D 64 is resistant to oil, maritime climate, ozone and UV radiation. Contact complement 2 A 250 V AC 15 or 1 A 24 V DC 13 (standard) or 4 A 250 V AC 15 (special) with positive opening operation 10 million (operating cycles) 20 million (operating cycles) Operation -40° C to +60° C Storage -50° C to +80° C Mechanical life D 64 Mechanical life DD 64 Permissible ambient temperature Climate resistance Damp heat constant Damp heat cyclic Degree of protection front Technical data see catalog 5/100 Description data see catalog 5/020 IEC 60068-2-78 IEC 60068-2-30 IP 54 IEC/EN 60529 1 Spindle block with schematic representation of the master controller installation and deflection directions. Version shown for left-hand side installation (right-hand side installation is mirror image). Type D64LQQ-02ZP+02ZP-… Pos. 1 D 64 1 3 1 5 7 left right 2 4 6 8 Deflection directions designated to DIN 15025 Type expansion DD 64 3 Weight gramm Type Price EURO 1100 D 64 483,- 1100 DD64 905,- 3 2 3 4 2 4 2 3-4 4 3-4 5 7.1 7.2 Double-handle controller left Double-handle controller right (dir. 1-2, 3-4) (dir. 5-6, 7-8) L R 10 20 21 21.1 21.2 21.4 21.5 22 23 24 25 26 27 28 28.2 28.3 29 36 Control-handle with knob solid Control-handle with latch for mechanical zero interlock by lifting by lifting, interlocking the gate by pushing down Mechanical zero interlock with command devices see catalog 1/274 Control-handle with dead man’s button 1 NO Control-handle with signal button 1 NO Control-handle with push button 1 NO Control-handle with flat push button 1 NO Control-handle with T-grip Control-handle with T-grip and push button side 1 NO Control-handle long or short -20 mm +20 mm More knobs, grips and T-grips with and without signal devices see catalog 1/270ff (for each direction for Pos. 20-28) Masterswitch (contact set) switching sequence 4-0-4 No. of contacts 2 4 6 8 10 12 30 31 32 33 34 35 36 Switching sequence 5-0-5 or 6-0-6 38 39 Spring return in 0-position Friction brake adjustable 40 Potentiometer e.t.c. each direction with mounted Wire-wound potentiometer T 130, with centre tap, 1,5 Watt wiper current max. 10 mA resistance 2 x 0,5k P021, 2 x 1k P022, 2 x 2k 2 x 10k P025 M MP MN 50,63,63,- 100 100 110 110 40 60 T H D DV Q QD 54,54,62,66,24,74,14,- S5 S8 Direction 1-2 and 3-4 each 1 masterswitch Switching program according contact-arrangement MS... see catalog 5/001 or to your contact-arrangement A… (for each direction) (for each direction) …P02 왏 P023, 2 x 5k 50 60 50 290 350 410 470 530 590 01 02 03 04 05 06 59,89,119,149,179,209,34,- 110 30 Z R 27,27,- 70 P 139,- (P) (P) 58,129,- P024, 41 42 43 Prepared for mounting potentiometer shaft 6 mm adjusting-angle 2 x 150° Prepared for mounting potentiometer e.t.c. adjusting-angle variable. more Potentiometer e.t.c. see catalog 1/240ff 52 More housing see catalog 1/350 60 61 Indicating labels not engraved with 2 or 4 arrows Engraving, each 10 characters 70 Command and indicating devices see catalog 1/360 C…, P… 9,10,- ® 1/161 Double-handle controller D 64 / DD 64 Industrial controllers T-grip D = -push button Knob solid D = -push button T = dead man’s button H = signal button M = latch for mechanical zero interlock 2011 58 MN MP To build in: direction 1-2 direction 3-4 Cover plate Type CAGE CLAMP® connection max. 2,5 mm2 01 02 03 04 05 06 Potentiometer T 130 No. of contacts Dimension A Dimension B 119 131 144 156 169 181 82 94 107 119 132 144 2 4 6 8 10 12 Hole pattern D64 double handle controller installation side L o. R special control handle handle contact set dir. 1-2 (5-6) spring return dir. 1-2 (5-6) Potentiometer dir. 1-2 (5-6) L S5 QQ - 02 Z P + 01 R P -X- A050 P024 +A05 P022 Potentiometer description dir. 3-4 (7-8) see 1/240ff Arrangement dir. 3-4 (7-8) see 5/001 Potentiometer description dir. 1-2 (5-6) see 1/240ff Arrangement dir. 1-2 (5-6) see 5/001 special please describe Potentiometer dir. 3-4 (7-8) friction brake dir. 3-4 (7-8) contact set dir. 3-4 (7-8) 37