U-Series / Molded Case Circuit Breaker Introduction | Wide and powerful range | UAB, UCB Type [ up to 1600AF ] | Compact size | Wide and powerful range • High breaking capacity in 60mm depth, up to 250AF • 50, 125, 250, 400, 630, 800, 1000, 1250, 1600AF • Application of current-limiting technology • Fixed or adjustable thermal trip mechanism up to 800AF • UAB type • Double protected electronic trip mechanism for 1600AF - up to 25kA at AC380/415V in W75 x H130 x D60mm • UCB type - up to 50kA at AC380/415V in W90/105 x H165 x D60mm | Various accessories | Reliable quality • Motor operator and operating handles for smooth operation • Terminal cover and terminal busbar for safety • Type-tested by KEMA Netherlands • DIN rail adapter and mounting base for easy installation • Switches and trip devices for control by signals 6 MCCB | Modern and customized design | UPB, HBL Type Miniature Type [ 125, 160, 250, 400, 630AF ] [ 30, 50, 100AF ] | High breaking capacity | Industrial and residential application • Up to 150kA at AC380/415V • Based on current-limiting technology • Ics = 100% Icu • Mini molded case circuit breaker • Mini earth leakage circuit breaker • Up to 100A, 10kA | Reliable quality | Various protection • Type-tested by international test authorities • KEMA for IEC standard, KERI for NEMA standard • Short-circuit and overload • Earth leakage protection | Diverse trip mechanism and application | Internal accessories • Fixed & adjustable thermal, electronic • Motor protection, nuclear power plant • Auxiliary switch • Trip alarm switch • Shunt trip Molded Case Circuit Breaker_ 7 U-Series / Molded Case Circuit Breaker Features | Adjustable rating in full range with diverse trip mechanisms | �U-Series MCCB adopts adjustable rating function in full range from 50 to 1600AF. With diverse trip mechanisms of U-Series MCCB, you will be provided with wide options for system design and more flexible load fluctuations. [ UAB, UCB type ] Fixed thermal Adjustable thermal [ UPB type ] Fixed thermal Adjustable thermal 8 Electronic Adjustable instantaneous for motor protection MCCB | Wide and powerful production range | �U-Series MCCB supplies you with wide and powerful production range; 3 to 1600A, 5 to 150kA at AC415V from general distribution boards to nuclear power plants. U-Series MCCB also completely covers Hi-Series MCCB range with better characteristics. Thermal magnetic type Icu 150 kA 130 kA 100 kA 85 kA 50 kA 42 kA 36 kA 30 kA 25 kA 18 kA 10 kA 5 kA (at 415V) Hydraulic magnetic Fixed thermal Adjustable thermal UPB160X UPB100X UPB160L UPB100L UPB100H UPB160H UPB100S UPB160S UCB100L UCB160L UCB100H UCB160H UCB50L UCB50H UCB100S UAB100S UAB100R, UCB100R UAB50H UAB50S, UCB50R UAB30R UAB50R UAB30C UAB50C 30AF UPB250X UCB630L UPB250L UCB800L UCB630H UCB400L UPB250H UCB800H UCB630S UPB250S UCB400H UCB800S UCB800R UCB250L UCB630R (45kA) (45kA) UCB250H UCB400S UCB250N UCB400R UCB250S UCB250R UAB60R UAB100C UAB60C 50AF 60AF 100AF 125AF 160AF 250AF 400AF 630AF 800AF Electronic type Icu 150 kA 130 kA 100 kA 85 kA UPB100X UPB160L UPB100L UPB100H UPB100S UPB250X UPB160X UPB250L UPB400H UPB250S UPB160S UPB630L UPB400L UPB250H UPB160H UPB630X UPB400X UPB630H UCB1000L UCB1000S UCB1250L UCB1250S UPB630S UPB400S UCB1600S 65 kA (at 415V) 125AF 160AF 250AF 400AF 630AF 1000AF 1250AF 1600AF Miniature type Fixed Thermal Icu 10 kA UBD30L, UBD30H UMB30S, UDB30S UGD30L, UGD30H UMG30S, UDG30S 5 kA 2.5 kA UMB50H, UDB50H UMG50H, UDG50H UMB30H, UDB30H UMG30H, UDG30H UMB50S, UDB50S UMG50S, UDG50S UDB100H UDG100H UDB100S UDG100S UMB30R UMG30R (at 220V) 30AF 50AF 100AF Moter protection - UPB type 125-250AF Q-class HBL type - 100-225AF Switch disconnector - UAD type 50-100AF, UCD type 50-1250AF, UPD type 125-630AF Molded Case Circuit Breaker_ 9 U-Series / Molded Case Circuit Breaker Features | High breaking capacity, realized by advanced technology and optimized design | �Our optimized design by advanced current-limiting technology allows U-Series MCCB to realize high breaking capacity in a smaller size compared to Hi-Series MCCB, contributing to compact design of system. Same breaking capacity in 30% smaller size High breaking capacity in same size �The current-limiting characteristic of U-Series MCCB also minimizes the effects from fault currents and offers cost-effectiveness. [UPB type] Handle Trip button Arc-chamber unit Trip(OCR) unit Terminal Mechanism Fixed contact device Moving contact device Maximized repulsive-force trip mechanism Realized by twin contact structure (two contacts in fixed contact device, other two in moving contact device), both updown direction repulsion of rotary structure, and u-shaped terminal structure of fixed contact. Contribute to increase of main contact travel distance, prevention of arc re-ignition, and correct lead of arc projection to arc chute. Arc pressure actuator (APA) Arc pressure occurred by short-circuit current can be detected through APA and operates trip mechanism before the response of trip sensor ▶ Minimizing total breaking time, Maximizing current-limiting performance 10 MCCB | Standardization of dimensions | �U-Series MCCB minimizes the difference in size of each model, so that they can be easily replaced whenever the specifications of the system changes. 50mm 60mm 50AF 125AF �UAB type : 30-100AF 250AF �UCB type : 50-250AF | Reliable quality and various applications | �U-Series MCCB is type-tested by international test authorities such as KEMA and KERI as well satisfying IEC60947-2 and NEMA AB-1 standards. It also acquired various marine classes and certificates for nuclear power plants. Molded Case Circuit Breaker_ 11 U-Series / Molded Case Circuit Breaker Features | Modern and refined design | Model name Line side terminal �UPB : Type �250 : Ampere frame size �X : Recognition code for order Rated frequency Utilization category Ampere frame size Suitability of isolation Rated current Standard Main characterisitics �Ui : Rated insulation voltage �Uimp : Rated impulse withstand voltage �Ue : Rated operational voltage �Icu : Rated ultimate short-circuit breaking capacity �Ics : Rated service short-circuit breaking capacity Trip unit Trip button Load side terminal Approvals and certificates 12 U-Series / Molded Case Circuit Breaker Quick Selection Table | UAB type / 30-100AF | Ampere frame 30 50 60 100 Model Number of poles Breaking capacity [Icu] (kA r.m.s.) Trip mechanism & Characteristics Dimensions (mm) Rated current (A) AC220V AC240V AC380V AC415V AC440V AC460V AC600V AC660V Hydraulic magnetic Thermal magnetic Fixed Adjustable UAB30C 2, 3 3,5,10,15,20,30 10 7.5/5 5 2.5 ○ - - UAB30R 2, 3 5,10,15,20,30 25 14/10 10 5 ○ - - UAB50C 2, 3, 4 5,10,15,20,30,40,50 10 7.5/5 5 2.5 ○ - UAB50R 2, 3, 4 5,10,15,20,30,40,50 25 14/10 10 5 ○ - - UAB50S 2, 3, 4 15,16,20,25,30,32,40,50 42 25 21 7.5 - ○ ○1) UAB50H 2, 3, 4 15,16,20,25,30,32,40,50 50 30 25 10 - ○ ○1) UAB60C 2, 3, 4 5,10,15,20,30,40,50,60 10 7.5/5 5 2.5 ○ - - UAB60R 2, 3, 4 5,10,15,20,30,40,50,60 25 14/10 10 5 ○ - - UAB100C 2, 3, 4 5,10,15,20,30,40,50,60,75,100 25 14/10 10 5 ○ - - UAB100R 2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100 42 25 21 7.5 - ○ ○1) UAB100S 2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100 50 30 25 10 - ○ ○1) Width Height Depth 50/75 130 60 50/75/100 130 60 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Not applicable to 2P breaker. | UCB type / 50-1600AF | Ampere frame Model 100 125 160 250 400 630 800 1000 1250 1600 Breaking capacity [Icu] (kA r.m.s.) Trip mechanism & Characteristics Dimensions (mm) Rated current (A) AC220V AC240V AC380V AC415V AC440V AC460V AC600V AC660V Thermal magnetic Fixed Adjustable Electronic 50 30/25 25 10 ○ - - UCB50H �2, 3, 4 15,16,20,25,30,32,40,50 85 42 42 20 ○ ○ - UCB50L �2, 3, 4 15,16,20,25,30,32,40,50 100 50 50 25 ○ ○ - UCB50R 50 Number of poles 2, 3, 4 15,20,30,40,50 UCB100R 2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100 50 30/25 25 10 ○ ○ - UCB100S 2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100 65 42/36 35 18 ○ ○ - UCB100H �2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100,125 85 42 42 20 ○ ○ - UCB100L �2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100,125 100 50 50 25 ○ ○ - UCB160H �2, 3, 4 100,125,160 85 42 42 20 ○ ○ - UCB160L �2, 3, 4 100,125,160 100 50 50 25 ○ ○ - UCB250R �2, 3, 4 125,150,160,175,200,225,250 35 25/18 18 7.5 ○ ○ - UCB250S �2, 3, 4 125,150,160,175,200,225,250 50 35/25 25 10 ○ ○ - UCB250N �2, 3, 4 125,150,160,175,200,225,250 65 42/36 35 18 ○ ○ - UCB250H �2, 3, 4 125,150,160,175,200,225,250 85 42 42 20 ○ ○ - UCB250L �2, 3, 4 125,150,160,175,200,225,250 100 50 50 25 ○ ○ - UCB400R �2, 3, 4 250,300,320,350,400 35 30 25 18 ○ ○ - UCB400S �2, 3, 4 250,300,320,350,400 50 42 35 22 ○ ○ - UCB400H �2, 3, 4 250,300,320,350,400 85 65 50 25 ○ ○ - UCB400L �2, 3, 4 250,300,320,350,400 125 100 85 30 ○ ○ - UCB630R �2, 3, 4 500,630 50 45 35 22 ○ ○ - UCB630S �2, 3, 4 500,630 100 65 50 25 ○ ○ - UCB630H �2, 3, 4 500,630 100 85 65 35 ○ ○ - UCB630L �2, 3, 4 500,630 125 100 85 35 ○ ○ - UCB800R �2, 3, 4 700,800 50 45 35 25 ○ ○ - UCB800S �2, 3, 4 700,800 100 65 50 25 ○ ○ - UCB800H �2, 3, 4 700,800 100 85 65 35 ○ ○ - UCB800L �2, 3, 4 700,800 125 100 85 35 ○ ○ - UCB1000S 3, 4 505-1000 100 100 75 40 - - ○ UCB1000L 3, 4 505-1000 150 130 100 60 - - ○ UCB1250S 3, 4 630-1250 100 100 75 40 - - ○ UCB1250L 3, 4 630-1250 150 130 100 60 - - ○ UCB1600S 3 640-1600 100 65 45 25 - - ○ ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. �2P breaker has same dimension as 3P breaker, but the middle pole is removed. 14 Width Height Depth 60/90/120 155 60 90/90/120 155 60 60/90/120 155 60 90/90/120 155 60 105/105/140 165 60 105/105/140 164 60 105/105/140 165 60 140/140/185 257 110 210/210/280 280 110 210/280 370 110/ 200 210 371 151 MCCB | UPB type / 125-630AF | Ampere frame 125 Model 250 400 630 Breaking capacity [Icu] (kA r.m.s.) Trip mechanism & Characteristics Dimensions (mm) Rated current (A) AC220V AC240V AC380V AC415V AC440V AC460V AC660V AC690V Thermal magnetic Electronic Fixed Adjustable UPB100S 3, 4 15,16,20,25,30,32,40,50,63,80,100,125 100 85 65 10 ○ ○ ○ UPB100H 3, 4 15,16,20,25,30,32,40,50,63,80,100,1251) 130 100 85 10 ○ ○ ○ UPB100L 3, 4 15,16,20,25,30,32,40,50,63,80,100,1251) 150 130 100 25 ○ ○ ○ 3, 4 1) 200 150 150 25 ○ ○ ○ UPB100X 160 Number of poles 1) 15,16,20,25,30,32,40,50,63,80,100,125 UPB160S 3, 4 100,125,160 100 85 65 10 ○ ○ ○ UPB160H 3, 4 100,125,1601) 130 100 85 10 ○ ○ ○ UPB160L 3, 4 100,125,1601) 150 130 100 25 ○ ○ ○ UPB160X 3, 4 100,125,1601) 200 150 150 25 ○ ○ ○ 1) UPB250S 3, 4 125,150,160,175,200,225,250 100 85 65 10 ○ ○ ○ UPB250H 3, 4 125,150,160,175,200,225,2501) 130 100 85 10 ○ ○ ○ UPB250L 3, 4 125,150,160,175,200,225,2501) 150 130 100 25 ○ ○ ○ UPB250X 3, 4 1) 125,150,160,175,200,225,250 200 150 150 25 ○ ○ ○ UPB400S 3, 4 200-400 100 85 65 10 - - ○ UPB400H 3, 4 200-400 130 100 85 10 - - ○ UPB400L 3, 4 200-400 150 130 100 25 - - ○ UPB400X 3, 4 200-400 200 150 150 25 - - ○ UPB630S 3, 4 320-630 100 85 65 10 - - ○ UPB630H 3, 4 320-630 130 100 85 10 - - ○ UPB630L 3, 4 320-630 150 130 100 25 - - ○ UPB630X 3, 4 320-630 200 150 150 25 - - ○ 1) Width Height Depth 105/140 165 86.5 140/185 255 117 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Rated current of electronic types are as followings; ∙UPB100: 50-125A ∙UPB160: 63-160A ∙UPB250: 100-250A | Motor protection / UPB type 125-250AF | Ampere frame 125 250 Model Number of poles Rated current (A) UPB100H 3 UPB100L 3 UPB250H UPB250L Breaking capacity [Icu] (kA r.m.s.) AC220V AC240V AC380V AC415V 2.5,3.2,6.3,12.5,20,32,50,63,80,100 130 2.5,3.2,6.3,12.5,20,32,50,63,80,100 150 3 125,150,175,200,225 3 125,150,175,200,225 Dimensions (mm) AC440V AC460V AC660V AC690V 100 85 10 130 100 25 130 100 85 10 150 130 100 25 Width Height Depth 105 165 86.5 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. | Q-class (for newclear power plant application) / HBL type 100-225AF | Ampere frame 100 225 Model Number of poles Rated current (A) Breaking capacity [Icu] (kA r.m.s.) AC220V AC240V AC380V AC440V AC480V AC660V AC415V AC460V AC500V AC690V Characteristics Dimensions (mm) Motor E1 class protection Width HBL103U 3 15,20,30,40,50,60,75,100 200 150 100 85 25 - HBL103UQ 3 15,20,30,40,50,60,75,100 200 150 100 85 25 ○ - HBL103UM 3 2.5,3.2,6.3,12.5,20,32,50,63,80,100 200 150 100 85 25 - ○ HBL103UMQ 3 2.5,3.2,6.3,12.5,20,32,50,63,80,100 200 150 100 85 25 ○ ○ HBL203U 3 125,150,175,200,225 200 150 100 85 25 - - HBL203UQ 3 125,150,175,200,225 200 150 100 85 25 ○ - HBL203UM 3 125,150,175,200,225 200 150 100 85 25 - ○ HBL203UMQ 3 125,150,175,200,225 200 150 100 85 25 ○ ○ Height Depth 165 86.5 - 105 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. Molded Case Circuit Breaker_ 15 U-Series / Molded Case Circuit Breaker Quick Selection Table | Switch disconnector / 50-1250AF | Type Ampere frame Model 50 UCD50H Dimensions (mm) Number Rated Ampere Type of poles current (A) Width Height Depth frame 3 50 Model Dimensions (mm) Number Rated of poles current (A) Width Height Depth UAD50C 3 50 UAD50S 3 50 100 UAD100R 3 100 50 90 155 60 100 UCD100S 3 100 125 UCD100H 3 125 160 UCD160H 3 160 105 165 60 125 UPD100S 3 125 UCD250S 3 250 105 164 60 160 UPD160S 3 160 UCD250H 3 250 105 165 60 250 UPD250S 3 250 400 UCD400S 3 400 140 257 110 400 UPD400S 3 400 630 UCD630S 3 630 630 UPD630S 3 630 800 UCD800S 3 800 1000 UCD1000S 3 1000 1250 UCD1250S 3 1250 UAD 75 130 60 105 165 86.5 140 255 117 250 UCD 210 280 110 210 370 110 UPD | Miniature type / 30-100AF | Type UBD Model Number Ampere Molded case Earth leakage of poles frame circuit breaker circuit breaker UBD30L 2 15,20,30 Rated residual current [I△n] (mA) for ELCB 15, 30 Breaking capacity [Icu] (kA r.m.s.) AC220V AC240V AC380V AC415V AC440V AC460V 5 - - 30 UGD UMB UGD30L Rated current (A) 30 UMG UBD30H UGD30H 2 15,20,30 15, 30 5 - - UMB30R UMG30R 2 15,20,30 15, 30 2.5 - - UMB30S UMG30S 2 15,20,30 15, 30 5 - - UMB30H UMG30H 2 15,20,30 15, 30 10 - - UMB50S UMG50S 2 15,20,30,40,50 15, 30 5 - - UMB50H UMG50H 2 15,20,30,40,50 15, 30 10 - - UDB30S UDG30S 2, 3 3,5,10,15,20,30 15, 30 5 2.5 2.5 5 2.5 2.5 10 5 5 5 2.5 2.5 5 2.5 2.5 10 5 5 Dimensions (mm) Width Height 35 82.5 Depth 42 60 33 70 57 35 80 60 50/75 96 60 75/75 96 60 50 30 UDB30H UDG30H 2, 3 5,10 15, 30 15,20,30 UDB UDG 50 UDB50S UDG50S 2, 3 UDB50H UDG50H 2, 3 5,10,15,20,30,40,50 5,10 15, 30 15, 30 15,20,30,40,50 UDB100S UDG100S �2, 3 15,20,30,40,50,60,75,100 30, 100 5 2.5 2.5 UDB100H UDG100H �2, 3 15,20,30,40,50,60,75,100 30, 100 10 5 5 100 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. �2P breaker has same dimension as 3P breaker, but the middle pole is removed. 16 U-Series / Molded Case Circuit Breaker Rating Overview | UAB type / 30-50AF | Model UAB30 UAB50 30AF 2, 3 IP20 A ○ overload, inst., short-circuit 3,5,10,15,20,30 5,10,15,20,30 AC690 AC660 DC250 6 C R 2.5 5 2.5 7.5 5 10 7.5/5 14/10 10 25 2.5 5 5 10 50 ○ 12×In ○ ○1) ○1) ○1) ○ ○ ○ ○ ○ ○1) ○1) ○ ○1) ○1) ○ ○ ○3) 25,000 15,000 50/75 130 60 82 0.45/0.65 50AF 2, 3, 4 2, 3, 4 IP20 IP20 A A ○ ○ overload, inst., short-circuit overload, inst., short-circuit 5,10,15,20,30,40,50 15,16,20,25,30,32,40,50 AC690 AC690 AC660 AC660 DC250 DC250 6 6 C R S H 2.5 5 7.5 10 2.5 7.5 7.5 14 5 10 21 25 7.5/5 14/10 25 30 10 25 42 50 2.5 5 10 14 5 10 15 20 50 25 ○ 12×In ○ 15-32A: 20×In, 40-100A: 10×In (0.8-0.9-1)×In 15-32A: 20×In, 40-100A: 10×In ○ ○ ○1) ○1) 1) ○ ○1) ○1) ○1) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○2) ○2) ○2) ○2) ○ ○ ○2) ○2) ○ ○1) ○1) ○ ○ ○ ○ ○3) ○3) 25,000 25,000 15,000 15,000 50/75/100 50/75/100 130 130 60 60 82 82 0.45/0.65/0.85 0.6/0.78/0.96 Figure Ampere frame size Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Recognition code for order AC600/660V, 50-60Hz Rated short-circuit Ultimate AC480/500V, 50-60Hz AC440/460V, 50-60Hz breaking [Icu] capacity (kA r.m.s.) AC380/415V, 50-60Hz AC220/240V, 50-60Hz IEC 60947-2 DC250V K 60947-2 DC125V Service [Ics] % of [Icu] Hydraulic Fixed thermal, magnetic Fixed instantaneous INST Trip mechanism Fixed thermal, & Protection Thermal Fixed instantaneous INST characteristics magnetic Adjustable thermal, LTD Fixed instantaneous INST Direct mounting by screw Both line & load side for Switchboard Line side only Mounting Plug-in for Distribution board DIN-rail with DIN-rail adaptor Terminal connection Screw Auxiliary switch AUX Trip alarm switch ALT Signal Shunt trip SHT Under voltage trip UVT Operating Surface type TFG handle Extended type TFH Accessories Operating Motor operator MOT Mechanical interlock MIF DIN-rail adaptor DRA Mounting Plug-in mounting base TDM Cage terminal block CTB Terminal Terminal cover TCF Interpole barrier TQQ Durability Mechanical operation (times) Electrical operation d a a Width c Dimensions b Height b 2/3/4P (mm) c Depth d Weight (㎏, breaker only) 2/3/4P ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 2) Available for 3P, 4P breaker 3) Supplied as standard component 18 MCCB | UAB type / 60-100AF | Model UAB60 UAB100 Figure Ampere frame size Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Recognition code for order AC600/660V, 50-60Hz Rated AC480/500V, 50-60Hz short-circuit Ultimate AC440/460V, 50-60Hz breaking [Icu] AC380/415V, 50-60Hz capacity (kA r.m.s.) AC220/240V, 50-60Hz IEC 60947-2 DC250V K 60947-2 DC125V Service [Ics] % of [Icu] Hydraulic Fixed thermal, magnetic Fixed instantaneous INST Trip mechanism Fixed thermal, & Protection Thermal Fixed instantaneous INST characteristics magnetic Adjustable thermal, LTD Fixed instantaneous INST Direct mounting by screw for Both line & load side Mounting Plug-in Switchboard Line side only for Distribution board DIN-rail with DIN-rail adaptor Terminal connection Screw Auxiliary switch AUX Trip alarm switch ALT Signal Shunt trip SHT Under voltage trip UVT Operating Surface type TFG handle Extended type TFH Operating Accessories Motor operator MOT Mechanical interlock MIF DIN-rail adaptor DRA Mounting Plug-in mounting base TDM Cage terminal block CTB Terminal Terminal cover TCF Interpole barrier TQQ Durability Mechanical operation (times) Electrical operation a Width d a c Dimensions b Height 2/3/4P b (mm) c Depth d Weight (㎏, breaker only) 2/3/4P 60AF 100AF 2, 3, 4 2, 3, 4 2, 3, 4 IP20 IP20 IP20 A A A ○ ○ ○ overload, inst., short-circuit overload, inst., short-circuit overload, inst., short-circuit 5,10,15,20,30,40,50,60 5,10,15,20,30,40,50,60,75,100 15,16,20,25,30,32,40,50,60,63,75,80,100 AC690 AC690 AC690 AC660 AC660 AC660 DC250 DC250 DC250 6 6 6 C R C R S 2.5 5 5 7.5 10 2.5 7.5 7.5 7.5 14 5 10 10 21 25 7.5/5 14/10 14/10 25 30 10 25 25 42 50 2.5 14 5 10 14 5 25 10 15 20 50 50 25 ○ ○ 12×In 12×In ○ 15-32A: 20×In, 40-100A: 10×In (0.8-0.9-1)×In2) 15-32A: 20×In, 40-100A: 10×In ○ ○ ○ ○ ○ ○ ○1) ○1) ○1) ○1) ○1) ○1) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○2) ○2) ○2) ○2) ○2) ○2) ○ ○ ○ ○2) ○2) ○2) ○ ○1) ○1) ○1) ○ ○ ○ ○ ○ ○ ○3) ○3) ○3) 25,000 25,000 25,000 10,000 10,000 10,000 50/75/100 50/75/100 50/75/100 130 130 130 60 60 60 82 82 82 0.45/0.65/0.85 0.45/0.65/0.85 0.6/0.78/0.96 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 2) Available for 3P, 4P breaker 3) Supplied as standard component Molded Case Circuit Breaker_ 19 U-Series / Molded Case Circuit Breaker Rating Overview | UCB type / 50-125AF | Model UCB50 UCB100 Figure Ampere frame size Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation 50AF Protection Rated current (A) Rating Rated insulation voltage [Ui] (V) Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Recognition code for order AC600/660V, 50-60Hz Rated AC480/500V, 50-60Hz short-circuit Ultimate AC440/460V, 50-60Hz breaking [Icu] AC380/415V, 50-60Hz capacity (kA r.m.s.) AC220/240V, 50-60Hz IEC 60947-2 DC250V K 60947-2 DC125V Service [Ics] % of [Icu] Fixed thermal, Trip Fixed instantaneous mechanism Thermal & Protection magnetic Adjustable thermal, characteristics Fixed instantaneous 2, 3, 4 IP20 A ○ overload, inst., short-circuit �2, 3, 4 IP20 A ○ overload, inst., short-circuit 15,20,30,40,50 15,16,20,25,30,32,40,50 AC690 AC660 DC250 6 R 10 14 25 30/25 50 14 20 50 ○ AC690 AC660 DC250 6 INST 10×In LTD - INST - Direct mounting by screw ○ Both line & load side ○1) for Switchboard Line side only Plug-in ○1) for Distribution board ○1) Terminal connection Screw ○ Auxiliary switch AUX ○ Trip alarm switch ALT ○ Signal Shunt trip SHT ○ Under voltage trip UVT ○ ○2) Operating Surface type TFG handle Extended type TFH ○2) Accessories Operating Motor operator MOT ○ Mechanical interlock MIF ○ Mounting Plug-in mounting base TDM ○1) Cage terminal block CTB ○ Terminal Terminal cover TCF ○ Interpole barrier TQQ ○3) Mechanical operation 25,000 Durability (times) Electrical operation 10,000 a Width 60/90/120 d a c b Height 155 Dimensions 2/3/4P b c Depth (mm) 60 d 84.5 Weight (㎏, breaker only) 2/3/4P 0.7/1.0/1.2 Mounting H 20 30 42 42 85 25 40 L 25 35 50 50 100 40 60 50 ○ 15-32A: 15×In, 40-50A: 10×In (0.8-0.9-1)×In 15-32A: 15×In, 40-50A: 10×In ○ ○1) ○1) ○1) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○3) 25,000 10,000 904)/90/120 155 60 84.5 0.9/1.0/1.3 100AF 2, 3, 4 IP20 A ○ overload, inst., short-circuit 15,16,20,25,30,32,40, 50,60,63,75,80,100 AC690 AC660 DC250 6 R S 10 18 14 25 25 35 30/25 42/36 50 65 14 18 20 25 75 ○ 10×In (0.8-0.9-1)×In 10×In ○ ○1) ○1) ○1) ○ ○ ○ ○ ○ ○2) ○2) ○ ○2) ○1) ○ ○ ○3) 25,000 10,000 60/90/120 155 60 84.5 0.7/1.0/1.2 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 2) Available for 3P, 4P breaker 3) Supplied as standard component 4) �2P breaker has same dimension as 3P breaker, but the middle pole is removed. 20 125AF �2, 3, 4 IP20 A ○ overload, inst., short-circuit 15,16,20,25,30,32,40, 50,60,63,75,80,100,125 AC690 AC660 DC250 6 H L 20 25 30 35 42 50 42 50 85 100 25 40 40 60 75 ○ 15-32A: 15×In, 40-125A: 10×In (0.8-0.9-1)×In 15-32A: 15×In, 40-125A: 10×In ○ ○1) ○1) ○1) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○1) ○ ○ ○3) 25,000 10,000 904)/90/120 155 60 84.5 0.9/1.0/1.3 MCCB | UCB type / 160-250AF | Model UCB160 UCB250 Figure Ampere frame size Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Recognition code for order AC600/660V, 50-60Hz AC480/500V, 50-60Hz Rated Ultimate AC440/460V, 50-60Hz short-circuit [Icu] AC380/415V, 50-60Hz breaking (kA r.m.s.) capacity AC220/240V, 50-60Hz DC250V IEC 60947-2 DC125V K 60947-2 Service [Ics] % of [Icu] Fixed thermal, Trip mechanism Thermal Fixed instantaneous INST & Protection magnetic Adjustable thermal, LTD characteristics Fixed instantaneous INST Direct mounting by screw Both line & load side for Switchboard Line side only Plug-in Mounting for Distribution board Screw Terminal connection Bus bar Auxiliary switch AUX Trip alarm switch ALT Signal Shunt trip SHT Under voltage trip UVT Operating Surface type TFG handle Extended type TFH Operating Accessories Motor operator MOT Mechanical interlock MIF Mounting Plug-in mounting base TDM Terminal bus bar TBB Cage terminal block CTB Terminal Terminal cover TCF Interpole barrier TQQ Durability Mechanical operation (times) Electrical operation a Width d a c b Height Dimensions 2/3/4P b (mm) c Depth d Weight (㎏, breaker only) 2/3/4P 160AF �2, 3, 4 IP20 A ○ overload, inst., short-circuit 100,125,160 AC690 AC660 DC250 6 H L 20 25 30 35 42 50 42 50 85 100 25 40 40 60 50 ○ 10×In (0.8-0.9-1)×In 10×In ○ ○1) ○1) ○1) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○1) ○ ○ ○ ○2) 25,000 10,000 1053)/105/140 165 60 84.5 1.1/1.3/1.6 250AF �2, 3, 4 IP20 A ○ overload, inst., short-circuit 125,150,160,175,200,225,250 AC690 AC660 DC250 6 R S N 7.5 10 18 10 14 25 18 25 35 25/18 35/25 42/36 35 50 65 10 14 18 15 20 25 50 ○ 10×In (0.8-0.9-1)×In 10×In ○ ○1) ○1) ○1) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○1) ○ ○ ○ ○2) 25,000 10,000 1053)/105/140 164 60 84 1.1/1.2/1.5 �2, 3, 4 IP20 A ○ overload, inst., short-circuit 125,150,160,175,200,225,250 AC690 AC660 DC250 6 H L 20 25 30 35 42 50 42 50 85 100 25 40 40 60 50 ○ 10×In (0.8-0.9-1)×In 10×In ○ ○1) ○1) ○1) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○1) ○ ○ ○ ○2) 25,000 10,000 1053)/105/140 165 60 84.5 1.1/1.3/1.6 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 2) Supplied as standard component 3) �2P breaker has same dimension as 3P breaker, but the middle pole is removed. Molded Case Circuit Breaker_ 21 U-Series / Molded Case Circuit Breaker Rating Overview | UCB type / 400-800AF | Model UCB400 UCB630 UCB800 400AF �2, 3, 4 IP20 A ○ overload, inst., short-circuit 250,300,320,350,400 AC690 AC660 DC250 6 R S H L 18 22 25 30 18 25 35 65 25 35 50 85 30 42 65 100 35 50 85 125 14 25 40 40 20 30 50 60 50 ○ 10×In (0.8-0.9-1)×In 10×In ○ ○1) ○1) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○2) ○1) ○ ○ ○ ○2) 20,000 6,000 1403)/140/185 257 110 145 4/4.5/5.4 630AF �2, 3, 4 IP20 A ○ overload, inst., short-circuit 500, 630 AC690 AC660 DC250 6 R S H L 22 25 35 35 25 45 50 65 35 50 65 85 45 65 85 100 50 100 100 125 20 40 40 40 30 50 50 60 50 ○ 10×In (0.8-0.9-1)×In 10×In ○ ○1) ○1) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○2) ○1) ○ ○ ○ ○2) 20,000 6,000 2103)/210/280 280 110 145 8.7/9.5/12.5 800AF �2, 3, 4 IP20 A ○ overload, inst., short-circuit 700, 800 AC690 AC660 DC250 6 R S H L 25 25 35 35 35 45 50 65 35 50 65 85 45 65 85 100 50 100 100 125 20 40 40 40 30 50 50 60 50 ○ 10×In (0.8-0.9-1)×In 10×In ○ ○1) ○1) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○2) ○1) ○ ○ ○ ○2) 10,000 3,000 2103)/210/280 280 110 145 8.7/9.5/12.5 Figure Ampere frame size Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Recognition code for order AC600/660V, 50-60Hz Rated AC480/500V, 50-60Hz short-circuit Ultimate AC440/460V, 50-60Hz breaking [Icu] capacity (kA r.m.s.) AC380/415V, 50-60Hz AC220/240V, 50-60Hz IEC 60947-2 DC250V K 60947-2 DC125V Service [Ics] % of [Icu] Fixed thermal, Trip mechanism Thermal Fixed instantaneous INST & Protection magnetic Adjustable thermal, LTD characteristics Fixed instantaneous INST Direct mounting by screw Mounting Both line & load side for Plug-in Switchboard Line side only Screw Terminal connection Bus bar Auxiliary switch AUX Trip alarm switch ALT Signal Shunt trip SHT Under voltage trip UVT Operating Surface type TFG handle Extended type TFH Operating Motor operator MOT Accessories Mechanical interlock MIF Extension handle THA Mounting Plug-in mounting base TDM Terminal bus bar TBB Cage terminal block CTB Terminal Terminal cover TCF Interpole barrier TQQ Durability Mechanical operation (times) Electrical operation a Width d a c b Height Dimensions 2/3/4P b (mm) c Depth d Weight (㎏, breaker only) 2/3/4P ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 2) Supplied as standard component 3) �2P breaker has same dimension as 3P breaker, but the middle pole is removed. 22 MCCB | UCB type / 1000-1600AF | Model UCB1000 UCB1250 UCB1600 1000AF 1250AF 1600AF Figure Ampere frame size Number of poles (P) 3, 4 3, 4 3 Degree of protection (without terminal bus bar) IP20 IP20 IP20 Utilization category A A A Suitability of isolation ○ ○ ○ overload, inst., short-circuit overload, inst., short-circuit overload, inst., short-circuit 505-1,000 630-1,250 640-1,600 Rated insulation voltage [Ui] (V) AC750 AC750 AC750 Rated operational voltage [Ue] (V) AC690 AC690 AC690 8 8 8 Protection Rated current (A) Rating Rated impulse withstand voltage [Uimp] (kV) Recognition code for order S L S L S AC600/660V, 50-60Hz 40 60 40 60 25 AC480/500V, 50-60Hz 75 100 75 100 35 AC440/460V, 50-60Hz 75 100 75 100 45 AC380/415V, 50-60Hz 100 130 100 130 65 AC220/240V, 50-60Hz IEC 60947-2 K 60947-2 Service [Ics] % of [Icu] 100 150 100 150 100 Rated short-circuit Ultimate breaking [Icu] capacity (kA r.m.s.) 50 50 (0.5-1)1)×In (15 setting) (0.5-1) 1)×In (15 setting) 50 Long time delay LTD Short time delay Trip Instantaneous mechanism Electronic Ground fault trip & Protection Pre-trip alarm characteristics I2T lamp STD (2-4-6-8-10)×Ir (2-4-6-8-10)×Ir INST (3-6-8-10-11)×In (3-6-8-10-11)×In GFT (0.2-0.3-0.4)×In (0.2-0.3-0.4)×In - PTA 0.9×Ir 0.9×Ir - ○ ○ - ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Pick-up LED Direct mounting by screw Mounting Terminal connection Signal Accessories Operating Bus bar AUX ○ ○ Trip alarm switch ALT ○ ○ - Shunt trip SHT ○ ○ ○ Under voltage trip UVT ○ ○ ○ Extended type TFH - - ○ Operating handle Motor operator MOT ○ ○ ○ Extension handle THA ○3) ○3) ○3) Terminal bus bar TBB ○ ○ ○4) TCF - - ○3) Interpole barrier 4) TQQ Durability Mechanical operation (times) Electrical operation Dimensions (mm) b (2-3-4-5-6-7-8-10)×In Auxiliary switch Terminal Terminal cover a (0.4-1) 2)×In (8 setting) d c 3/4P ○3) ○3) ○3) 10,000 10,000 10,000 3,000 3,000 3,000 a Width 210/280 210/280 210 b Height 370 370 371 c Depth 110/200 110/200 151 159/249 159/249 215 d Weight (㎏, breaker only) 3/4P 4) 13/17 25/33 13.5/17.5 25.5/33.5 27 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) (0.5-1): (0.63-0.8-1)x(0.8-0.85-0.9-0.95-1) 2) (0.4-1): (0.4-0.5-0.6-0.7-0.8-0.9-0.95-1) 3) Supplied as standard component 4) Supplied as standard component that attached in breaker Molded Case Circuit Breaker_ 23 U-Series / Molded Case Circuit Breaker Rating Overview | UPB type / 125-250AF | Model UPB100 UPB160 UPB250 Figure Ampere frame size 125AF 160AF Number of poles (P) 3, 4 3, 4 Degree of protection (with terminal cover) IP20 IP20 Utilization category A A Suitability of isolation ○ ○ Protection overload, inst., short-circuit overload, inst., short-circuit Thermal magnetic type 15,16,20,25,30,32,40,50,63,80,100,125 100,125,160 Rated current (A) Electronic type 50-125 63-160 Rated insulation voltage [Ui] (V) AC750 AC750 Rating AC690 AC690 Rated operational voltage [Ue] (V) DC5001) DC5001) Rated impulse withstand voltage [Uimp] (kV) 8 8 Recognition code for order S H L X S H L X AC660/690V, 50-60Hz 10 10 25 25 10 10 25 25 Rated AC480/500V, 50-60Hz 50 65 85 85 50 65 85 85 short-circuit Ultimate AC440/460V, 50-60Hz 65 85 100 150 65 85 100 150 breaking [Icu] AC380/415V, 50-60Hz 85 100 130 150 85 100 130 150 capacity (kA r.m.s.) AC220/240V, 50-60Hz 100 130 150 200 100 130 150 200 IEC 60947-2 DC250V 501) 651) 851) 1001) 501) 651) 851) 1001) K 60947-2 DC125V 651) 1001) 1001) 1001) 651) 1001) 1001) 1001) Service [Ics] % of [Icu] 100 100 Fixed thermal, Fixed instantaneous ○2) ○2) Thermal 2) Trip Adjustable thermal, Fixed inst. ○ ○2) mechanism magnetic Adjustable thermal, Adjustable inst. ○2) & Protection 2) LTD, STD, INST ○ ○2) characteristics Electronic PTA, Pick-up LED ○ ○ Direct mounting by screw ○ ○ Mounting Both line & load side ○3) ○3) for Plug-in Switchboard Line side only ○3) ○3) Screw ○ ○ Terminal connection Bus bar ○ ○ Auxiliary switch AUX ○ ○ Trip alarm switch ALT ○ ○ Signal Shunt trip SHT ○ ○ Under voltage trip UVT ○ ○ ○ ○ Operating Surface type TFG handle Extended type TFH ○ ○ Operating Motor operator MOT ○ ○ Accessories Mechanical interlock MIF ○ ○ Padlock plate PLD ○ ○ Mounting Plug-in mounting base TDM ○3) ○3) Terminal bus bar TBB ○ ○ Cage terminal block CTB ○ ○ Terminal Terminal cover TCF ○ ○ Interpole barrier TQQ ○4) ○4) Mechanical operation 25,000 25,000 Durability (times) Electrical operation 10,000 10,000 a Width 105/140 105/140 d a c b Height 165 165 Dimensions 3/4P b (mm) c Depth 86.5 86.5 d 112 112 Weight (㎏, breaker only) 3/4P 1.8/2.2 2.0/2.4 250AF 3, 4 IP20 A ○ overload, inst., short-circuit 125,150,160,175,200,225,250 100-250 AC750 AC690 DC5001) 8 S H L X 10 10 25 25 50 65 85 85 65 85 100 150 85 100 130 150 100 130 150 200 501) 651) 851) 1001) 651) 1001) 1001) 1001) 100 ○2) ○2) ○2) ○2) ○ ○ ○3) ○3) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○3) ○ ○ ○ ○4) 25,000 10,000 105/140 165 86.5 112 2.0/2.4 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) DC is not applicable for electronic breaker. 2) For the detail protection characteristics, please refer to following pages; ∙UPB100: page 92 ∙UPB160: page 98 ∙UPB250: page 102 3) Available for 3P breaker 4) Supplied as standard component 24 MCCB | UPB type / 400-630AF | Model UPB400 UPB630 Figure Ampere frame size Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Recognition code for order Rated AC660/690V, 50-60Hz short-circuit Ultimate AC480/500V, 50-60Hz breaking [Icu] capacity (kA r.m.s.) AC440/460V, 50-60Hz AC380/415V, 50-60Hz IEC 60947-2 AC220/240V, 50-60Hz K 60947-2 Service [Ics] % of [Icu] Trip LTD, STD, INST mechanism GFT, I2T lamp & Protection characteristics Electronic PTA, Pick-up LED Direct mounting by screw Mounting Both line & load side for Plug-in Switchboard Line side only Screw Terminal connection Bus bar Auxiliary switch AUX Trip alarm switch ALT Signal Shunt trip SHT Under voltage trip UVT Operating Surface type TFG handle Extended type TFH Motor operator MOT Operating Accessories Mechanical interlock MIF Padlock plate PLD Extension handle THA Mounting Plug-in mounting base TDM Terminal bus bar TBB Cage terminal block CTB Terminal Terminal cover TCF Interpole barrier TQQ Durability Mechanical operation (times) Electrical operation a Width d a c b Height Dimensions 3/4P b (mm) c Depth d Weight (㎏, breaker only) 3/4P S 10 50 65 85 100 400AF 3, 4 IP20 A ○ overload, inst., short-circuit 200-400 AC750 AC690 8 H L 10 25 65 85 85 100 100 130 130 150 100 ○1) ○1) ○ ○ ○2) ○2) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○3) ○2) ○ ○ ○ ○3) 20,000 6,000 140/185 255 117 159.5 6.0/7.8 X 25 85 150 150 200 S 10 50 65 85 100 630AF 3, 4 IP20 A ○ overload, inst., short-circuit 320-630 AC750 AC690 8 H L X 10 25 25 65 85 85 85 100 150 100 130 150 130 150 200 100 ○1) ○1) ○ ○ ○2) ○2) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○3) ○2) ○ ○ ○ ○3) 20,000 6,000 140/185 255 117 159.5 6.0/7.8 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) For the detail protection characteristics, please refer to following pages; ∙UPB400: page 108 ∙UPB630: page 110 2) Available for 3P breaker 3) Supplied as standard component Molded Case Circuit Breaker_ 25 U-Series / Molded Case Circuit Breaker Rating Overview | Motor protection / UPB type 125-250AF | Model UPB100 UPB250 125AF 3 IP20 A ○ instantaneous, short-circuit 2.5,3.2,6.3,12.5,20,32,50,63,80,100 AC750 AC690 DC500 8 H L 10 25 65 85 85 100 100 130 130 150 65 85 100 100 100 250AF 3 IP20 A ○ instantaneous, short-circuit 125,150,175,200,225 AC750 AC690 DC500 8 H L 10 25 65 85 85 100 100 130 130 150 65 85 100 100 100 Figure Ampere frame size Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Recognition code for order AC660/690V, 50-60Hz Rated short-circuit Ultimate AC480/500V, 50-60Hz AC440/460V, 50-60Hz breaking [Icu] capacity (kA r.m.s.) AC380/415V, 50-60Hz AC220/240V, 50-60Hz IEC 60947-2 DC250V K 60947-2 DC125V Service [Ics] % of [Icu] Trip mechanism Thermal Adjustable instantaneous & Protection magnetic characteristics Direct mounting by screw Both line & load side Mounting for Plug-in Switchboard Line side only Screw Terminal connection Bus bar Auxiliary switch AUX Trip alarm switch ALT Signal Shunt trip SHT Under voltage trip UVT Operating Surface type TFG handle Extended type TFH Operating Motor operator MOT Accessories Mechanical interlock MIF Padlock plate PLD Mounting Plug-in mounting base TDM Terminal bus bar TBB Cage terminal block CTB Terminal Terminal cover TCF Interpole barrier TQQ Durability Mechanical operation (times) Electrical operation Width a d a c b Height Dimensions 3P b c Depth (mm) d Weight (㎏, breaker only) 3P (6-7-8-9-10-11-12-13)×In ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○1) 25,000 10,000 105 165 86.5 112 1.8 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Supplied as standard component 26 (6-7-8-9-10-11-12-13)×In ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○1) 25,000 10,000 105 165 86.5 112 2.0 MCCB | Q-class (for nuclear power plant application) / HBL type 100-225AF | HBL103 Model HBL203 Figure Ampere frame size Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Recognition code for order AC660/690V, 50-60Hz Rated AC480/500V, 50-60Hz short-circuit Ultimate AC440/460V, 50-60Hz breaking [Icu] AC380/415V, 50-60Hz capacity (kA r.m.s.) AC220/240V, 50-60Hz DC250V IEC 60947-2 DC125V K 60947-2 Service [Ics] % of [Icu] Trip mechanism Thermal Fixed thermal, & Protection Fixed instantaneous INST characteristics magnetic Adjustable instantaneous Non-E1 Q-class E1 Direct mounting by screw Both line & load side Mounting for Plug-in Switchboard Line side only Screw Terminal connection Bus bar Auxiliary switch AUX Trip alarm switch ALT Signal Shunt trip SHT Under voltage trip UVT Operating Surface type TFG handle Extended type TFH Operating Motor operator MOT Accessories Mechanical interlock MIF Padlock plate PLD Mounting Plug-in mounting base TDM Terminal bus bar TBB Cage terminal block CTB Terminal Terminal cover TCF Interpole barrier TQQ Durability Mechanical operation (times) Electrical operation a Width d a c b Height Dimensions 3P b (mm) c Depth d Weight (㎏, breaker only) 3P 100AF 225AF 3 3 IP20 IP20 A A ○ ○ overload, inst., short-circuit instantaneous, short-circuit overload, inst., short-circuit instantaneous, short-circuit 15,20,30,40, 2.5,3.2,6.3,12.5, 125,150,175,200,225 50,60,75,100 20,32,50,63,80,100 AC750 AC750 AC690 AC690 DC500 DC500 8 8 U1) UQ1) UM1) UMQ1) U1) UQ1) UM1) UMQ1) 25 25 25 25 25 25 25 25 85 85 85 85 85 85 85 85 100 100 100 100 100 100 100 100 150 150 150 150 150 150 150 150 200 200 200 200 200 200 200 200 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 ○ ○ 10×In 10×In (6-7-8-9-10-11-12-13)×In (6-7-8-9-10-11-12-13)×In ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○2) ○2) ○2) ○2) ○2) ○2) 2) ○ ○2) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○3) ○3) 3) ○ ○3) 25,000 25,000 10,000 10,000 105 105 165 165 86.5 86.5 112 112 1.8 2.0 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) ∙U: non-E1 class ∙UQ: E1 class ∙UM: non-E1 class, motor protection ∙UQM: E1 class, motor protection 2) Signal accessories shall be installed in breaker before ex-working. 3) Supplied as standard component Molded Case Circuit Breaker_ 27 U-Series / Molded Case Circuit Breaker Rating Overview | Switch disconnector / UAD type 50-100AF | Model UAD50C UAD50S UAD100R Figure Ampere frame size 50AF Number of poles (P) Degree of protection (with terminal cover) 3 3 IP20 IP20 IP20 Utilization category A A A Suitability of isolation ○ ○ ○ Conventional thermal current [Ith] (A) 50 50 100 Rated current (A) 50 50 100 AC690 AC690 AC690 Rated insulation voltage [Ui] (V) AC660 AC660 AC660 DC250 DC250 DC250 Rated impulse withstand voltage [Uimp] (kV) 6 6 6 Rated short-circuit making capacity [Icm] (kA peak at AC460V) 17 52.5 52.5 Rated short-time withstand current for 1sec. [Icw] (kA r.m.s.) 1 1 1 Mechanical operation (times) 25,000 25,000 25,000 Electrical operation (times) 15,000 15,000 10,000 ○ ○ ○ Both line & load side for Switchboard Line side only ○ ○ ○ ○ ○ ○ for Distribution board ○ ○ ○ with DIN-rail adaptor - ○ ○ Screw ○ ○ ○ Rated operational voltage [Ue] (V) Rating Durability Direct mounting by screw Mounting Plug-in DIN-rail Terminal connection Signal Accessories Operating Mounting Terminal a Dimensions (mm) b Auxiliary switch AUX ○ ○ ○ Trip alarm switch ALT ○ ○ ○ Shunt trip SHT ○ ○ ○ Under voltage trip UVT ○ ○ ○ Operating Surface type handle Extended type TFG ○ ○ ○ TFH ○ ○ ○ Motor operator MOT ○ ○ ○ Mechanical interlock MIF ○ ○ ○ DIN-rail adaptor DRA - ○ ○ Plug-in mounting base TDM ○ ○ ○ Terminal cover TCF ○ ○ ○ Interpole barrier TQQ ○ ○ ○1) d c 3P Weight (㎏, breaker only) 3P ※ 1) Supplied as standard component 1) 1) a Width 75 75 75 b Height 130 130 130 c Depth 60 60 60 82 82 82 0.65 0.78 0.78 d 28 100AF 3 MCCB | Switch disconnector / UCD type 50-250AF | Model UCD50H UCD100S UCD100H UCD160H UCD250S UCD250H Ampere frame size 50AF 100AF 125AF 160AF Number of poles (P) 3 3 3 3 3 3 IP20 IP20 IP20 IP20 IP20 IP20 Figure Degree of protection (with terminal cover) 250AF Utilization category A A A A A A Suitability of isolation ○ ○ ○ ○ ○ ○ Conventional thermal current [Ith] (A) 50 100 125 160 250 250 Rated current (A) 50 100 125 160 250 250 AC690 AC690 AC690 AC690 AC690 AC690 Rated insulation voltage [Ui] (V) AC660 AC660 AC660 AC660 AC660 AC660 DC250 DC250 DC250 DC250 DC250 DC250 6 6 6 6 6 6 Rated short-circuit making capacity [Icm] (kA peak at AC460V) 105 73.5 105 105 73.5 105 Rated short-time withstand current for 1sec. [Icw] (kA r.m.s.) 1 1 1 2 2 2 Mechanical operation (times) 25,000 25,000 25,000 25,000 25,000 25,000 Electrical operation (times) 10,000 10,000 10,000 10,000 10,000 10,000 ○ ○ ○ ○ ○ ○ Both line & load side for Switchboard Line side only ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ for Distribution board ○ ○ ○ ○ ○ ○ Screw ○ ○ ○ ○ ○ ○ Bus bar - - - ○ ○ ○ Rated operational voltage [Ue] (V) Rating Rated impulse withstand voltage [Uimp] (kV) Durability Direct mounting by screw Mounting Plug-in Terminal connection Signal Auxiliary switch AUX ○ ○ ○ ○ ○ ○ Trip alarm switch ALT ○ ○ ○ ○ ○ ○ Shunt trip SHT ○ ○ ○ ○ ○ ○ UVT ○ ○ ○ ○ ○ ○ TFG ○ ○ ○ ○ ○ ○ TFH ○ ○ ○ ○ ○ ○ Motor operator MOT ○ ○ ○ ○ ○ ○ Mechanical interlock MIF ○ ○ ○ ○ ○ ○ TDM - ○ ○ ○ ○ ○ CTB ○ ○ ○ ○ ○ ○ TCF ○ ○ ○ ○ ○ ○ TQQ ○ ○ ○ ○ 1) ○ ○1) Under voltage trip Operating Surface type Operating handle Extended type Accessories Mounting Plug-in mounting base Cage terminal block Terminal Terminal cover Interpole barrier a Dimensions (mm) b d c 3P 1) 1) 1) a Width 90 90 90 105 105 105 b Height 155 155 155 165 164 165 c Depth d Weight (㎏, breaker only) 3P 1) 60 60 60 60 60 60 84.5 84.5 84.5 84.5 84 84.5 1 1 1 1.3 1.2 1.3 ※ 1) Supplied as standard component Molded Case Circuit Breaker_ 29 U-Series / Molded Case Circuit Breaker Rating Overview | Switch disconnector / UCD type 400-1250AF | Model UCD400S UCD630S UCD800S UCD1000S UCD1250S Ampere frame size 400AF 630AF 800AF 1000AF 1250AF Number of poles (P) 3 3 3 3 3 IP20 IP20 IP20 IP201) IP201) Figure Degree of protection (with terminal cover) Utilization category A A A A A Suitability of isolation ○ ○ ○ ○ ○ Conventional thermal current [Ith] (A) 400 630 800 1,000 1,250 Rated current (A) 400 630 800 1,000 1,250 AC690 AC690 AC690 AC750 AC750 Rated insulation voltage [Ui] (V) AC660 AC660 AC660 AC690 AC690 DC250 DC250 DC250 - - 6 6 6 8 8 Rated short-circuit making capacity [Icm] (kA peak at AC460V) 187 187 187 165 165 Rated short-time withstand current for 1sec. [Icw] (kA r.m.s.) 4 6.3 8 10 12.5 Mechanical operation (times) 20,000 20,000 10,000 10,000 10,000 Electrical operation (times) 6,000 6,000 3,000 3,000 3,000 ○ ○ ○ - - Both line & load side for Switchboard Line side only ○ ○ ○ - - ○ ○ ○ - - Screw ○ ○ ○ - - Rated operational voltage [Ue] (V) Rating Rated impulse withstand voltage [Uimp] (kV) Durability Direct mounting by screw Mounting Plug-in Terminal connection Signal ○ ○ ○ ○ ○ Auxiliary switch AUX ○ ○ ○ ○ ○ Trip alarm switch ALT ○ ○ ○ ○ ○ Shunt trip SHT ○ ○ ○ ○ ○ Under voltage trip UVT ○ ○ ○ ○ ○ Operating Surface type handle Extended type TFG ○ ○ ○ - - TFH ○ ○ ○ - - MOT ○ ○ ○ ○ ○ Mechanical interlock MIF ○ ○ ○ - - Extension handle THA ○2) ○2) ○2) ○2) ○2) TDM ○ ○ ○ - - Terminal bus bar TBB ○ ○ ○ ○3) ○3) Cage terminal block CTB ○ ○ ○ - - Terminal cover TCF ○ ○ ○ - - Interpole barrier TQQ ○2) ○2) ○2) ○2) ○2) a Width 140 210 210 210 210 b Height 257 280 280 370 370 c Depth 110 110 110 110 110 145 145 145 159 159 4.5 9.5 9.5 13 13.5 Bus bar Operating Motor operator Accessories Mounting Plug-in mounting base Terminal a Dimensions (mm) b d c 3P d Weight (㎏, breaker only) 3P ※ 1) Without terminal bus bar 2) Supplied as standard component 3) Supplied as standard component that attached in breaker 30 MCCB | Switch disconnector / UPD type 125-630AF | Model UPD100S UPD160S UPD250S UPD400S UPD630S Ampere frame size 125AF 160AF 250AF 400AF 630AF Number of poles (P) 3 3 3 3 3 IP20 IP20 IP20 IP20 IP20 Figure Degree of protection (with terminal cover) Utilization category A A A A A Suitability of isolation ○ ○ ○ ○ ○ Conventional thermal current [Ith] (A) 125 160 250 400 630 Rated current (A) 125 160 250 400 630 AC750 AC750 AC750 AC750 AC750 Rated insulation voltage [Ui] (V) AC690 AC690 AC690 AC690 AC690 DC500 DC500 DC500 - - 8 8 8 8 8 Rated short-circuit making capacity [Icm] (kA peak at AC460V) 200 200 200 200 200 Rated short-time withstand current for 1sec. [Icw] (kA r.m.s.) 1 1.6 2.5 4 6.3 Mechanical operation (times) 25,000 25,000 25,000 20,000 20,000 Electrical operation (times) 10,000 10,000 10,000 6,000 6,000 ○ ○ ○ ○ ○ Both line & load side for Switchboard Line side only ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Screw ○ ○ ○ ○ ○ Rated operational voltage [Ue] (V) Rating Rated impulse withstand voltage [Uimp] (kV) Durability Direct mounting by screw Mounting Plug-in Terminal connection Signal Operating Accessories ○ ○ ○ ○ ○ Auxiliary switch AUX ○ ○ ○ ○ ○ Trip alarm switch ALT ○ ○ ○ ○ ○ Shunt trip SHT ○ ○ ○ ○ ○ Under voltage trip UVT ○ ○ ○ ○ ○ Operating Surface type handle Extended type TFG ○ ○ ○ ○ ○ TFH ○ ○ ○ ○ ○ Motor operator MOT ○ ○ ○ ○ ○ Mechanical interlock MIF ○ ○ ○ ○ ○ Padlock plate PLD ○ ○ ○ - - Extension handle THA - - - ○1) ○1) Bus bar Mounting Plug-in mounting base Terminal a Dimensions (mm) b TDM ○ ○ ○ ○ ○ Terminal bus bar TBB ○ ○ ○ ○ ○ Cage terminal block CTB ○ ○ ○ ○ ○ Terminal cover TCF ○ ○ ○ ○ ○ Interpole barrier TQQ ○1) ○1) ○1) ○1) ○1) d c 3P a Width 105 105 105 140 140 b Height 165 165 165 255 255 c Depth 86.5 86.5 86.5 117 117 112 112 112 159.5 159.5 1.8 2 2 6 6 d Weight (㎏, breaker only) 3P ※ 1) Supplied as standard component Molded Case Circuit Breaker_ 31 U-Series / Molded Case Circuit Breaker Rating Overview | Miniature type / Molded case circuit breaker 30-100AF | Model UBD30 UMB30 UMB50 UDB30 UDB50 UDB100 Ampere frame size 30AF 30AF 50AF 30AF 50AF 100AF Number of poles (P) 2 2 2 2, 3 2, 3 �2, 3 Degree of protection IP20 IP20 IP20 IP20 IP20 IP20 Utilization category A A A A A A overload, short-circuit overload, short-circuit overload, short-circuit overload, short-circuit overload, short-circuit overload, short-circuit 15, 20, 30 15, 20, 30 15, 20, 30, 40, 50 31), 5, 10, 15, 20, 30 5, 10, 15, 20, 30, 40, 50 15, 20, 30, 40, 50, 60, 75, 100 Rated insulation voltage [Ui] (V) AC250 AC250 AC250 AC460 AC460 AC460 Rated operational voltage [Ue] (V) AC220 AC220 AC220 2P: AC220 3P: AC220/460 2P: AC220 3P: AC220/460 2P: AC220 3P: AC220/460 6 6 6 6 6 6 Figure Protection Rated current (A) Rating Rated impulse withstand voltage [Uimp] (kV) Recognition code for order L H AC440/460V, 50-60Hz Rated short-circuit Ultimate [Icu] breaking (kA r.m.s.) AC380/415V, 50-60Hz capacity IEC 60947-2 K 60947-2 AC220/240V, 50-60Hz Direct mounting by screw DIN-rail Terminal connection Signal Accessories Dimensions (mm) b H S H S H 2.5 5 - - - 2.5 5-10A: 2.5 5-10A: 2.5 2.55 15-30A: 5 15-30A: 5 2.5 5 5 10 2.5 5 10 5 50 10 50 5 5-10A: 5 15-30A:10 5 5-10A: 5 15-30A:10 50 50 50 - - - ○ - ○ ○ ○ ○ ○ ○ ○ - ○ - - - - ○ ○ ○ ○ ○ ○ ○ ○ ○ - ○ ○ ○ ○ ○ ○ ○ Auxiliary switch AUX - - - ○ ○ ○ Trip alarm switch ALT - - - ○ ○ ○ Shunt trip SHT - - - ○ ○ ○ Terminal cover TCF - - - ○ ○ ○ Interpole barrier TQQ - - - ○ ○ ○ a Width 35 33 35 35 50/75 50/75 752)/75 b Height 82.5 70 80 80 96 96 96 c Depth d c 2/3P d Weight (kg, breaker only) 2/3P 32 S 5-10A: 2.5 5-10A: 2.5 2.5 15-30A: 5 15-30A: 5 ○ Terminal a H 2.5 - Screw S - ○ Mounting H - 50 Hydraulic magnetic Trip mechanism Thermal magnetic S - 5 Service [Ics] % of [Icu] R 42 60 42 60 60 60 60 60 54.6 76 57 76 76 80 80 80 0.12 0.14 0.1 0.13 0.15 0.2/0.35 0.2/0.35 0.2/0.35 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) 3A is not applicable for UDB30H. 2) �2P breaker has same dimension as 3P breaker, but the middle pole is removed. MCCB | Miniature type / Earth leakage circuit breaker 30-100AF | Model UGD30 UMG30 UMG50 UDG30 UDG50 UDG100 Ampere frame size 30AF 30AF 50AF 30AF 50AF 100AF Number of poles (P) 2 2 2 2, 3 2, 3 �2, 3 Degree of protection IP20 IP20 IP20 IP20 IP20 IP20 Utilization category A A A A A A Figure earth leakage, earth leakage, earth leakage, earth leakage, overload, overload, overload, overload, short-circuit short-circuit short-circuit short-circuit Protection 15, 20, 30 15, 20, 30 15, 20, 30, 40, 50 31), 5, 10, 15, 20, 30 5, 10, 15, 20, 30, 40, 50 15, 20, 30, 40, 50, 60, 75, 100 Rated residual current [I△n] (mA) 15, 30 15, 30 15, 30 15, 30 15, 30 30, 100 Rated insulation voltage [Ui] (V) AC250 AC250 AC250 AC460 AC460 AC460 Rated operational voltage [Ue] (V) AC220 AC220 AC220 Rated current (A) Rating Rated operating time (sec.) Recognition code for order 6 6 6 6 6 6 0.03 0.03 0.03 0.03 0.03 L H Rated AC440/460V, 50-60Hz short-circuit Ultimate breaking [Icu] capacity (kA r.m.s.) AC380/415V, 50-60Hz IEC 60947-2 K 60947-2 Signal Accessories Terminal a b S H S H S H S H - - 2.5 5-10A: 2.5 15-30A: 5 2.5 5-10A: 2.5 15-30A: 5 2.5 5 - - - 2.5 5-10A: 2.5 15-30A: 5 2.5 5-10A: 2.5 15-30A: 5 2.5 5 5 5-10A: 5 15-30A: 10 5 5-10A: 5 15-30A: 10 5 10 2.5 5 10 5 10 50 50 50 50 by current transformer by current transformer by current transformer by current transformer by current transformer by current transformer ○ ○ ○ ○ ○ ○ - - - ○ ○ ○ ○ - - - ○ - ○ ○ ○ ○ ○ ○ - ○ - - - - ○ ○ ○ ○ ○ Direct mounting by screw ○ - DIN-rail H 50 Hydraulic magnetic Trip mechanism Thermal magnetic Terminal connection S 50 Service [Ics] % of [Icu] Mounting R - 5 AC220/240V, 50-60Hz Earth leakage detection Earth leakage protection Earth leakage test button Earth leakage indicator 2P: AC220 2P: AC220 2P: AC220 3P: AC220/460 3P: AC220/460 3P: AC220/460 0.03 Rated impulse withstand voltage [Uimp] (kV) Dimensions (mm) earth leakage, earth leakage, overload, overload, short-circuit short-circuit ○ Screw ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Auxiliary switch AUX - - - ○ ○ ○ Trip alarm switch ALT - - - ○ ○ ○ Terminal cover TCF - - - ○ ○ ○ TQQ - a Width 35 b Height c Depth Interpole barrier d c 2/3P d Weight (kg, breaker only) 2/3P - 82.5 - ○ ○ ○ 33 35 35 50/75 50/75 752)/75 96 70 80 80 96 96 42 60 42 60 60 60 60 60 54.6 76 57 76 76 80 80 80 0.12 0.14 0.1 0.13 0.15 0.33/0.44 0.33/0.44 0.46/0.63 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) 3A is not applicable for UDG30H. 2) �2P breaker has same dimension as 3P breaker, but the middle pole is removed. Molded Case Circuit Breaker_ 33 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UAB type / 30AF | �UAB30C 7.5/5kA �UAB30R 14/10kA UAB30C Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated short-circuit breaking capacity IEC 60947-2 K 60947-2 Trip mechanism & Protection characteristics Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) AC600/660V, 50-60Hz AC480/500V, 50-60Hz AC440/460V, 50-60Hz Ultimate [Icu] AC380/415V, 50-60Hz (kA r.m.s.) AC220/240V, 50-60Hz DC250V DC125V Service [Ics] % of [Icu] Hydraulic magnetic Fixed thermal, Fixed instantaneous INST Direct mounting by screw Both line & load side for Switchboard Line side only for Distribution board Terminal connection Screw Mechanical operation Durability (times) Electrical operation a Width d a c b Height Dimensions 2/3P b (mm) c Depth d Weight (kg, breaker only) 2/3P Mounting Plug-in UAB30R 2, 3 IP20 A ○ overload, inst., short-circuit 3,5,10,15,20,30 5,10,15,20,30 AC690 AC660 DC250 6 2.5 5 2.5 7.5 5 10 7.5/5 14/10 10 25 2.5 5 5 10 50 ○ 12×In ○ ○1) ○1) ○1) ○ 25,000 15,000 50/75 130 60 82 0.45/0.65 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker ■ Accessories �Signal Auxiliary switch Trip alarm switch Shunt trip1) Under voltage trip 2) 36 1ab, Right-hand-side 2ab, Right-hand-side AUX 10A R1 AUX 10A R2 1ab, Right-hand-side ALT 10A R1 DC24V DC100-110V SHT 10A A SHT 10A C DC24V DC100-110V �UVT 10A J �UVT 10A L AC100-120V SHT 10A F AC100-120V �UVT 10A N ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. AC200-230V AC200-230V �UVT 10A P AC380-415V SHT 10A H AC380-415V �UVT 10A Q AC440-480V AC440-480V �UVT 10A R MCCB �Operating Upper TFG 10AS U4 TFG 10AL U4 Power supply direction S type Operating Surface L type 1) handle S type Extended L type Right TFG 10AS R4 TFH 10AS TFH 10AL AC/DC110V MOT 10A ADC110 3 pole MIF 10A 3 DC24V MOT 10A DC24 2 pole - Motor operator2) Mechanical interlock Left TFG 10AS L4 TFG 10AL L4 AC/DC220V MOT 10A ADC220 ※ 1) Available for 3P breaker. For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting Plug-in1) Structure Mounting base Connection 2C contact 3C contact block 2) Conn. block barrier For both line & load side TDM 10AP CBM 10AB 2 CBM 10AB 3 CBM BARR For line side only TDF 10A - ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal 3EA/SET CTB 10A 3S Cage terminal block 2 pole TCF 10AP 2 Terminal cover1) Interpole barrier 2) 3 pole TCF 10AP 3 TQQ 10A 2EA/SET ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 2EA, 3 pole 4EA ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Hydraulic magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V 표준품 주문코드 UAB30C 7.5/5kA UAB30R 14/10kA 2 pole 3 pole Rated current Code Unit (EA) 3A 5A 10A 15A 20A 30A 5A 10A 15A 20A 30A UAB30C 2PT4S0000C 00003 UAB30C 2PT4S0000C 00005 UAB30C 2PT4S0000C 00010 UAB30C 2PT4S0000C 00015 UAB30C 2PT4S0000C 00020 UAB30C 2PT4S0000C 00030 UAB30R 2PT4S0000C 00005 UAB30R 2PT4S0000C 00010 UAB30R 2PT4S0000C 00015 UAB30R 2PT4S0000C 00020 UAB30R 2PT4S0000C 00030 30 30 30 30 30 30 30 30 30 30 30 Code UAB30C 3PT4S0000C 00003 UAB30C 3PT4S0000C 00005 UAB30C 3PT4S0000C 00010 UAB30C 3PT4S0000C 00015 UAB30C 3PT4S0000C 00020 UAB30C 3PT4S0000C 00030 UAB30R 3PT4S0000C 00005 UAB30R 3PT4S0000C 00010 UAB30R 3PT4S0000C 00015 UAB30R 3PT4S0000C 00020 UAB30R 3PT4S0000C 00030 Unit (EA) 20 20 20 20 20 20 20 20 20 20 20 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M1 Specification Category 50℃ Model / Breaking capacity at AC380/415V 표준품 주문코드 UAB30C 7.5/5kA UAB30R 14/10kA 2 pole 3 pole Rated current Code Unit (EA) 3A 5A 10A 15A 20A 30A 5A 10A 15A 20A 30A UAB30C 2PT5S0000C 00003 UAB30C 2PT5S0000C 00005 UAB30C 2PT5S0000C 00010 UAB30C 2PT5S0000C 00015 UAB30C 2PT5S0000C 00020 UAB30C 2PT5S0000C 00030 UAB30R 2PT5S0000C 00005 UAB30R 2PT5S0000C 00010 UAB30R 2PT5S0000C 00015 UAB30R 2PT5S0000C 00020 UAB30R 2PT5S0000C 00030 30 30 30 30 30 30 30 30 30 30 30 Code UAB30C 3PT5S0000C 00003 UAB30C 3PT5S0000C 00005 UAB30C 3PT5S0000C 00010 UAB30C 3PT5S0000C 00015 UAB30C 3PT5S0000C 00020 UAB30C 3PT5S0000C 00030 UAB30R 3PT5S0000C 00005 UAB30R 3PT5S0000C 00010 UAB30R 3PT5S0000C 00015 UAB30R 3PT5S0000C 00020 UAB30R 3PT5S0000C 00030 Unit (EA) 20 20 20 20 20 20 20 20 20 20 20 Screw type terminal connection, No option, 50/60Hz MCCB /M1 Molded Case Circuit Breaker_ 37 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UAB type / 50AF | �UAB50C 7.5/5kA �UAB50R 14/10kA UAB50C Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated short-circuit breaking capacity IEC 60947-2 K 60947-2 Trip mechanism & Protection characteristics 2, 3, 4 IP20 A ○ overload, inst., short-circuit 5,10,15,20,30,40,50 AC690 AC660 DC250 6 Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) AC600/660V, 50-60Hz AC480/500V, 50-60Hz AC440/460V, 50-60Hz Ultimate AC380/415V, 50-60Hz [Icu] (kA r.m.s.) AC220/240V, 50-60Hz DC250V DC125V Service [Ics] % of [Icu] Hydraulic magnetic Fixed thermal, Fixed instantaneous 2.5 2.5 5 7.5/5 10 2.5 5 5 7.5 10 14/10 25 5 10 50 ○ 12×In ○ ○1) ○1) ○1) ○ 25,000 15,000 50/75/100 130 60 82 0.45/0.65/0.85 INST Direct mounting by screw Both line & load side for Switchboard Line side only for Distribution board Terminal connection Screw Mechanical operation Durability (times) Electrical operation a Width d a c b Height Dimensions 2/3/4P b (mm) c Depth d Weight (kg, breaker only) 2/3/4P Mounting UAB50R Plug-in ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker ■ Accessories �Signal Auxiliary switch Trip alarm switch Shunt trip1) Under voltage trip 2) 38 1ab, Right-hand-side 2ab, Right-hand-side AUX 10A R1 AUX 10A R2 1ab, Right-hand-side ALT 10A R1 DC24V DC100-110V SHT 10A A SHT 10A C DC24V DC100-110V �UVT 10A J �UVT 10A L AC100-120V SHT 10A F AC100-120V �UVT 10A N ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. AC200-230V AC200-230V �UVT 10A P AC380-415V SHT 10A H AC380-415V �UVT 10A Q AC440-480V AC440-480V �UVT 10A R MCCB �Operating Upper TFG 10AS U4 TFG 10AL U4 Power supply direction S type Operating Surface L type 1) handle S type Extended L type Right TFG 10AS R4 TFH 10AS TFH 10AL AC/DC110V MOT 10A ADC110 3 pole MIF 10A 3 DC24V MOT 10A DC24 2 pole - Motor operator 2) Mechanical interlock Left TFG 10AS L4 TFG 10AL L4 AC/DC220V MOT 10A ADC220 4 pole MIF 10A 4 ※ 1) Available for 3P, 4P breaker. For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting 1) Plug-in Structure Mounting base Connection 2C contact block 2) 3C contact Conn. block barrier For both line & load side TDM 10AP CBM 10AB 2 CBM 10AB 3 CBM BARR For line side only TDF 10A - ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal 3EA/SET CTB 10A 3S 2 pole TCF 10AP 2 Cage terminal block Terminal cover1) Interpole barrier 2) 2EA/SET 4EA/SET CTB 10A 4S 3 pole TCF 10AP 3 TQQ 10A 4 pole TCF 10AP 4 ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 2EA, 3 pole 4EA, 4 pole 6EA ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Hydraulic magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V 표준품 주문코드 UAB50C 7.5/5kA UAB50R 14/10kA Rated current 5A 10A 15A 20A 30A 40A 50A 5A 10A 15A 20A 30A 40A 50A 2 pole Code UAB50C 2PT4S0000C 00005 UAB50C 2PT4S0000C 00010 UAB50C 2PT4S0000C 00015 UAB50C 2PT4S0000C 00020 UAB50C 2PT4S0000C 00030 UAB50C 2PT4S0000C 00040 UAB50C 2PT4S0000C 00050 UAB50R 2PT4S0000C 00005 UAB50R 2PT4S0000C 00010 UAB50R 2PT4S0000C 00015 UAB50R 2PT4S0000C 00020 UAB50R 2PT4S0000C 00030 UAB50R 2PT4S0000C 00040 UAB50R 2PT4S0000C 00050 Unit (EA) 30 30 30 30 30 30 30 30 30 30 30 30 30 30 3 pole Code UAB50C 3PT4S0000C 00005 UAB50C 3PT4S0000C 00010 UAB50C 3PT4S0000C 00015 UAB50C 3PT4S0000C 00020 UAB50C 3PT4S0000C 00030 UAB50C 3PT4S0000C 00040 UAB50C 3PT4S0000C 00050 UAB50R 3PT4S0000C 00005 UAB50R 3PT4S0000C 00010 UAB50R 3PT4S0000C 00015 UAB50R 3PT4S0000C 00020 UAB50R 3PT4S0000C 00030 UAB50R 3PT4S0000C 00040 UAB50R 3PT4S0000C 00050 Unit (EA) 20 20 20 20 20 20 20 20 20 20 20 20 20 20 4 pole Code UAB50C 4PT4S0000C 00005 UAB50C 4PT4S0000C 00010 UAB50C 4PT4S0000C 00015 UAB50C 4PT4S0000C 00020 UAB50C 4PT4S0000C 00030 UAB50C 4PT4S0000C 00040 UAB50C 4PT4S0000C 00050 UAB50R 4PT4S0000C 00005 UAB50R 4PT4S0000C 00010 UAB50R 4PT4S0000C 00015 UAB50R 4PT4S0000C 00020 UAB50R 4PT4S0000C 00030 UAB50R 4PT4S0000C 00040 UAB50R 4PT4S0000C 00050 Unit (EA) Specification Category 16 16 16 16 16 Screw type 16 terminal 16 connection, 16 No option, 16 50/60Hz 16 16 16 16 16 MCCB /M1 50℃ Model / Breaking capacity at AC380/415V 표준품 주문코드 UAB50C 7.5/5kA UAB50R 14/10kA Rated current 5A 10A 15A 20A 30A 40A 50A 5A 10A 15A 20A 30A 40A 50A 2 pole Code UAB50C 2PT5S0000C 00005 UAB50C 2PT5S0000C 00010 UAB50C 2PT5S0000C 00015 UAB50C 2PT5S0000C 00020 UAB50C 2PT5S0000C 00030 UAB50C 2PT5S0000C 00040 UAB50C 2PT5S0000C 00050 UAB50R 2PT5S0000C 00005 UAB50R 2PT5S0000C 00010 UAB50R 2PT5S0000C 00015 UAB50R 2PT5S0000C 00020 UAB50R 2PT5S0000C 00030 UAB50R 2PT5S0000C 00040 UAB50R 2PT5S0000C 00050 Unit (EA) 30 30 30 30 30 30 30 30 30 30 30 30 30 30 3 pole Code UAB50C 3PT5S0000C 00005 UAB50C 3PT5S0000C 00010 UAB50C 3PT5S0000C 00015 UAB50C 3PT5S0000C 00020 UAB50C 3PT5S0000C 00030 UAB50C 3PT5S0000C 00040 UAB50C 3PT5S0000C 00050 UAB50R 3PT5S0000C 00005 UAB50R 3PT5S0000C 00010 UAB50R 3PT5S0000C 00015 UAB50R 3PT5S0000C 00020 UAB50R 3PT5S0000C 00030 UAB50R 3PT5S0000C 00040 UAB50R 3PT5S0000C 00050 Unit (EA) 20 20 20 20 20 20 20 20 20 20 20 20 20 20 4 pole Code UAB50C 4PT5S0000C 00005 UAB50C 4PT5S0000C 00010 UAB50C 4PT5S0000C 00015 UAB50C 4PT5S0000C 00020 UAB50C 4PT5S0000C 00030 UAB50C 4PT5S0000C 00040 UAB50C 4PT5S0000C 00050 UAB50R 4PT5S0000C 00005 UAB50R 4PT5S0000C 00010 UAB50R 4PT5S0000C 00015 UAB50R 4PT5S0000C 00020 UAB50R 4PT5S0000C 00030 UAB50R 4PT5S0000C 00040 UAB50R 4PT5S0000C 00050 Unit (EA) Specification Category 16 16 16 16 16 Screw type 16 terminal 16 connection, 16 No option, 16 50/60Hz 16 16 16 16 16 MCCB /M1 Molded Case Circuit Breaker_ 39 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UAB type / 50AF | �UAB50S 25kA �UAB50H 30kA UAB50S UAB50H Number of poles (P) 2, 3, 4 Degree of protection (with terminal cover) IP20 Utilization category A Suitability of isolation ○ Protection overload, inst., short-circuit Rated current (A) 15,16,20,25,30,32,40,50 Rated insulation voltage [Ui] (V) Rating AC690 AC660 Rated operational voltage [Ue] (V) DC250 Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit breaking capacity Ultimate [Icu] (kA r.m.s.) IEC 60947-2 K 60947-2 7.5 10 AC480/500V, 50-60Hz 7.5 14 AC440/460V, 50-60Hz 21 25 AC380/415V, 50-60Hz 25 30 AC220/240V, 50-60Hz 42 50 DC250V 10 14 DC125V 15 20 Service [Ics] % of [Icu] Trip Thermal mechanism & Protection magnetic characteristics 25 Fixed thermal, Fixed instantaneous Adjustable thermal, Fixed instantaneous ○ INST 15-32A: 20×In, 40-100A: 10×In LTD (0.8-0.9-1)×In 2) INST 15-32A: 20×In, 40-100A: 10×In ○ Direct mounting by screw Both line & load side Mounting Plug-in DIN-rail Terminal connection 6 AC600/660V, 50-60Hz ○1) for Switchboard Line side only ○1) for Distribution board ○1) with DIN-rail adaptor ○ Screw ○ Durability Mechanical operation 25,000 (times) Electrical operation 15,000 a Dimensions (mm) b d c 2/3/4P a Width 50/75/100 b Height 130 c Depth 60 d Weight (kg, breaker only) 2/3/4P 82 0.6/0.78/0.96 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 2) Available for 3P, 4P breaker 40 MCCB ■ Accessories �Signal 1ab, Right-hand-side Auxiliary switch Trip alarm switch Shunt trip 1) Under voltage trip 2) 1ab, Left-hand-side AUX 10UA R1 AUX 10UA L1 1ab, Right-hand-side 1ab, Left-hand-side ALT 10UA R1 ALT 10UA L1 DC24V DC100-110V AC100-120V AC200-230V AC380-415V SHT 10UA A SHT 10UA C SHT 10UA F SHT 10UA H SHT 10UA B SHT 10UA D DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V UVT 10UA J UVT 10UA L UVT 10UA N UVT 10UA P UVT 10UA Q UVT 10UA R AC440-480V ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Operating Upper Right Left S type TFG 10UAS U4 TFG 10UAS R4 TFG 10UAS L4 L type TFG 10UAL U4 - TFG 10UAL L4 Power supply direction Operating Surface handle1) Extended TFH 10UAS S type TFH 10UAL L type Motor operator 2) DC24V AC/DC110V AC/DC220V MOT 10UA DC24 MOT 10UA ADC110 MOT 10UA ADC220 Mechanical interlock 2 pole 3 pole 4 pole - MIF 10UA 3 MIF 10UA 4 ※ 1) Available for 3P, 4P breaker. For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting DRA 10UA DIN-rail adaptor Structure Mounting base Plug-in1) Connection 2C contact block2) 3C contact Conn. block barrier For both line & load side For line side only TDM 10AP TDF 10A CBM 10AB 2 - CBM 10AB 3 - CBM BARR - ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal 3EA/SET Cage terminal block CTB 10A 3S Terminal cover1) Interpole barrier2) 4EA/SET 2EA/SET CTB 10A 4S 2 pole 3 pole 4 pole TCF 10AP 2 TCF 10AP 3 TCF 10AP 4 TQQ 10A ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 2EA, 3 pole 4EA, 4 pole 6EA Molded Case Circuit Breaker_ 41 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V Rated current 2 pole 3 pole 4 pole Code Unit (EA) Code Unit (EA) 15A UAB50S 2PT4S0000C 00015 30 UAB50S 3PT4S0000C 00015 20 UAB50S 4PT4S0000C 00015 16 16A UAB50S 2PT4S0000C 00016 30 UAB50S 3PT4S0000C 00016 20 UAB50S 4PT4S0000C 00016 16 20A UAB50S 2PT4S0000C 00020 Code Unit (EA) Specification Category 30 UAB50S 3PT4S0000C 00020 20 UAB50S 4PT4S0000C 00020 16 UAB50S 25A UAB50S 2PT4S0000C 00025 30 UAB50S 3PT4S0000C 00025 20 UAB50S 4PT4S0000C 00025 16 25kA 30A UAB50S 2PT4S0000C 00030 30 UAB50S 3PT4S0000C 00030 20 UAB50S 4PT4S0000C 00030 16 32A UAB50S 2PT4S0000C 00032 30 UAB50S 3PT4S0000C 00032 20 UAB50S 4PT4S0000C 00032 16 40A UAB50S 2PT4S0000C 00040 30 UAB50S 3PT4S0000C 00040 20 UAB50S 4PT4S0000C 00040 50A UAB50S 2PT4S0000C 00050 30 UAB50S 3PT4S0000C 00050 20 UAB50S 4PT4S0000C 00050 15A UAB50H 2PT4S0000C 00015 30 UAB50H 3PT4S0000C 00015 20 UAB50H 4PT4S0000C 00015 16A UAB50H 2PT4S0000C 00016 30 UAB50H 3PT4S0000C 00016 20 UAB50H 4PT4S0000C 00016 16 Screw type 16 terminal connection, 16 No option, 50/60Hz 16 20A UAB50H 2PT4S0000C 00020 30 UAB50H 3PT4S0000C 00020 20 UAB50H 4PT4S0000C 00020 16 UAB50H 25A UAB50H 2PT4S0000C 00025 30 UAB50H 3PT4S0000C 00025 20 UAB50H 4PT4S0000C 00025 16 30kA 30A UAB50H 2PT4S0000C 00030 30 UAB50H 3PT4S0000C 00030 20 UAB50H 4PT4S0000C 00030 16 32A UAB50H 2PT4S0000C 00032 30 UAB50H 3PT4S0000C 00032 20 UAB50H 4PT4S0000C 00032 16 40A UAB50H 2PT4S0000C 00040 30 UAB50H 3PT4S0000C 00040 20 UAB50H 4PT4S0000C 00040 16 50A UAB50H 2PT4S0000C 00050 30 UAB50H 3PT4S0000C 00050 20 UAB50H 4PT4S0000C 00050 16 MCCB /M2 50℃ Model / Breaking capacity at AC380/415V 42 Rated current 2 pole 3 pole 4 pole Unit (EA) Code Unit (EA) 15A UAB50S 2PT5S0000C 00015 30 UAB50S 3PT5S0000C 00015 20 UAB50S 4PT5S0000C 00015 16 16A UAB50S 2PT5S0000C 00016 30 UAB50S 3PT5S0000C 00016 20 UAB50S 4PT5S0000C 00016 16 20A UAB50S 2PT5S0000C 00020 30 UAB50S 3PT5S0000C 00020 20 UAB50S 4PT5S0000C 00020 16 UAB50S 25A UAB50S 2PT5S0000C 00025 30 UAB50S 3PT5S0000C 00025 20 UAB50S 4PT5S0000C 00025 16 25kA 30A UAB50S 2PT5S0000C 00030 30 UAB50S 3PT5S0000C 00030 20 UAB50S 4PT5S0000C 00030 16 32A UAB50S 2PT5S0000C 00032 30 UAB50S 3PT5S0000C 00032 20 UAB50S 4PT5S0000C 00032 16 40A UAB50S 2PT5S0000C 00040 30 UAB50S 3PT5S0000C 00040 20 UAB50S 4PT5S0000C 00040 50A UAB50S 2PT5S0000C 00050 30 UAB50S 3PT5S0000C 00050 20 UAB50S 4PT5S0000C 00050 15A UAB50H 2PT5S0000C 00015 30 UAB50H 3PT5S0000C 00015 20 UAB50H 4PT5S0000C 00015 16A UAB50H 2PT5S0000C 00016 30 UAB50H 3PT5S0000C 00016 20 UAB50H 4PT5S0000C 00016 16 Screw type 16 terminal connection, 16 No option, 16 50/60Hz Code Unit (EA) Specification Category Code 20A UAB50H 2PT5S0000C 00020 30 UAB50H 3PT5S0000C 00020 20 UAB50H 4PT5S0000C 00020 16 UAB50H 25A UAB50H 2PT5S0000C 00025 30 UAB50H 3PT5S0000C 00025 20 UAB50H 4PT5S0000C 00025 16 30kA 30A UAB50H 2PT5S0000C 00030 30 UAB50H 3PT5S0000C 00030 20 UAB50H 4PT5S0000C 00030 16 32A UAB50H 2PT5S0000C 00032 30 UAB50H 3PT5S0000C 00032 20 UAB50H 4PT5S0000C 00032 16 40A UAB50H 2PT5S0000C 00040 30 UAB50H 3PT5S0000C 00040 20 UAB50H 4PT5S0000C 00040 16 50A UAB50H 2PT5S0000C 00050 30 UAB50H 3PT5S0000C 00050 20 UAB50H 4PT5S0000C 00050 16 MCCB /M2 MCCB �Adjustable thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V Rated current 3 pole 4 pole Code Unit (EA) Code Unit (EA) 15A UAB50S 3PT4S0000C 00015F 20 UAB50S 4PT4S0000C 00015F 16 16A UAB50S 3PT4S0000C 00016F 20 UAB50S 4PT4S0000C 00016F 16 20A UAB50S 3PT4S0000C 00020F 20 UAB50S 4PT4S0000C 00020F 16 UAB50S 25A UAB50S 3PT4S0000C 00025F 20 UAB50S 4PT4S0000C 00025F 16 25kA 30A UAB50S 3PT4S0000C 00030F 20 UAB50S 4PT4S0000C 00030F 16 32A UAB50S 3PT4S0000C 00032F 20 UAB50S 4PT4S0000C 00032F 16 40A UAB50S 3PT4S0000C 00040F 20 UAB50S 4PT4S0000C 00040F 16 50A UAB50S 3PT4S0000C 00050F 20 UAB50S 4PT4S0000C 00050F 16 15A UAB50H 3PT4S0000C 00015F 20 UAB50H 4PT4S0000C 00015F 16 16A UAB50H 3PT4S0000C 00016F 20 UAB50H 4PT4S0000C 00016F 16 20A UAB50H 3PT4S0000C 00020F 20 UAB50H 4PT4S0000C 00020F 16 UAB50H 25A UAB50H 3PT4S0000C 00025F 20 UAB50H 4PT4S0000C 00025F 16 30kA 30A UAB50H 3PT4S0000C 00030F 20 UAB50H 4PT4S0000C 00030F 16 32A UAB50H 3PT4S0000C 00032F 20 UAB50H 4PT4S0000C 00032F 16 40A UAB50H 3PT4S0000C 00040F 20 UAB50H 4PT4S0000C 00040F 16 50A UAB50H 3PT4S0000C 00050F 20 UAB50H 4PT4S0000C 00050F 16 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V Rated current 3 pole 4 pole Code Unit (EA) Code Unit (EA) 15A UAB50S 3PT5S0000C 00015F 20 UAB50S 4PT5S0000C 00015F 16 16A UAB50S 3PT5S0000C 00016F 20 UAB50S 4PT5S0000C 00016F 16 20A UAB50S 3PT5S0000C 00020F 20 UAB50S 4PT5S0000C 00020F 16 UAB50S 25A UAB50S 3PT5S0000C 00025F 20 UAB50S 4PT5S0000C 00025F 16 25kA 30A UAB50S 3PT5S0000C 00030F 20 UAB50S 4PT5S0000C 00030F 16 32A UAB50S 3PT5S0000C 00032F 20 UAB50S 4PT5S0000C 00032F 16 40A UAB50S 3PT5S0000C 00040F 20 UAB50S 4PT5S0000C 00040F 16 50A UAB50S 3PT5S0000C 00050F 20 UAB50S 4PT5S0000C 00050F 16 15A UAB50H 3PT5S0000C 00015F 20 UAB50H 4PT5S0000C 00015F 16 16A UAB50H 3PT5S0000C 00016F 20 UAB50H 4PT5S0000C 00016F 16 20A UAB50H 3PT5S0000C 00020F 20 UAB50H 4PT5S0000C 00020F 16 UAB50H 25A UAB50H 3PT5S0000C 00025F 20 UAB50H 4PT5S0000C 00025F 16 30kA 30A UAB50H 3PT5S0000C 00030F 20 UAB50H 4PT5S0000C 00030F 16 32A UAB50H 3PT5S0000C 00032F 20 UAB50H 4PT5S0000C 00032F 16 40A UAB50H 3PT5S0000C 00040F 20 UAB50H 4PT5S0000C 00040F 16 50A UAB50H 3PT5S0000C 00050F 20 UAB50H 4PT5S0000C 00050F 16 Molded Case Circuit Breaker_ 43 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UAB type / 60AF | �UAB60C 7.5/5kA �UAB60R 14/10kA UAB60C 2, 3, 4 IP20 A ○ overload, inst., short-circuit 5,10,15,20,30,40,50,60 AC690 AC660 DC250 6 Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit breaking capacity IEC 60947-2 K 60947-2 Trip mechanism & Protection characteristics 2.5 2.5 5 7.5/5 10 2.5 5 AC600/660V, 50-60Hz AC480/500V, 50-60Hz AC440/460V, 50-60Hz Ultimate [Icu] AC380/415V, 50-60Hz (kA r.m.s.) AC220/240V, 50-60Hz DC250V DC125V Service [Ics] % of [Icu] Hydraulic magnetic Fixed thermal, Fixed instantaneous INST Both line & load side for Switchboard Line side only for Distribution board Terminal connection Screw Mechanical operation Durability (times) Electrical operation a Width d a c b Height Dimensions 2/3/4P b (mm) c Depth d Plug-in Weight (kg, breaker only) 5 7.5 10 14/10 25 14 25 50 ○ 12×In ○ ○ ○ 1) ○ ○1) 25,000 10,000 50/75/100 130 60 82 Direct mounting by screw Mounting UAB60R 0.45/0.65/0.85 2/3/4P ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker ■ Accessories �Signal Auxiliary switch Trip alarm switch Shunt trip1) Under voltage trip 2) 44 1ab, Right-hand-side 2ab, Right-hand-side AUX 10A R1 AUX 10A R2 1ab, Right-hand-side ALT 10A R1 DC24V DC100-110V SHT 10A A SHT 10A C DC24V DC100-110V �UVT 10A J �UVT 10A L AC100-120V SHT 10A F AC100-120V �UVT 10A N ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. AC200-230V AC200-230V �UVT 10A P AC380-415V SHT 10A H AC380-415V �UVT 10A Q AC440-480V AC440-480V �UVT 10A R MCCB �Operating Power supply direction S type Operating Surface L type 1) handle S type Extended L type Upper TFG 10AS U4 TFG 10AL U4 Right TFG 10AS R4 TFH 10AS TFH 10AL AC/DC110V MOT 10A ADC110 3 pole MIF 10A 3 DC24V MOT 10A DC24 2 pole - Motor operator 2) Mechanical interlock Left TFG 10AS L4 TFG 10AL L4 AC/DC220V MOT 10A ADC220 4 pole MIF 10A 4 ※ 1) Available for 3P, 4P breaker. For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting Plug-in1) Structure Mounting base Connection 2C contact block2) 3C contact Conn. block barrier For both line & load side TDM 10AP CBM 10AB 2 CBM 10AB 3 CBM BARR For line side only TDF 10A - ※ 1) Available for 3P, 4P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal 3EA/SET CTB 10A 3S 2 pole TCF 10AP 2 Cage terminal block Terminal cover 1) Interpole barrier2) 2EA/SET 4EA/SET CTB 10A 4S 3 pole TCF 10AP 3 TQQ 10A 4 pole TCF 10AP 4 ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 2EA, 3 pole 4EA, 4 pole 6EA ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Hydraulic magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UAB60C 7.5/5kA UAB60R 14/10kA Rated current 5A 10A 15A 20A 30A 40A 50A 60A 5A 10A 15A 20A 30A 40A 50A 60A 2 pole Code UAB60C 2PT4S0000C 00005 UAB60C 2PT4S0000C 00010 UAB60C 2PT4S0000C 00015 UAB60C 2PT4S0000C 00020 UAB60C 2PT4S0000C 00030 UAB60C 2PT4S0000C 00040 UAB60C 2PT4S0000C 00050 UAB60C 2PT4S0000C 00060 UAB60R 2PT4S0000C 00005 UAB60R 2PT4S0000C 00010 UAB60R 2PT4S0000C 00015 UAB60R 2PT4S0000C 00020 UAB60R 2PT4S0000C 00030 UAB60R 2PT4S0000C 00040 UAB60R 2PT4S0000C 00050 UAB60R 2PT4S0000C 00060 Unit (EA) 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 3 pole Code UAB60C 3PT4S0000C 00005 UAB60C 3PT4S0000C 00010 UAB60C 3PT4S0000C 00015 UAB60C 3PT4S0000C 00020 UAB60C 3PT4S0000C 00030 UAB60C 3PT4S0000C 00040 UAB60C 3PT4S0000C 00050 UAB60C 3PT4S0000C 00060 UAB60R 3PT4S0000C 00005 UAB60R 3PT4S0000C 00010 UAB60R 3PT4S0000C 00015 UAB60R 3PT4S0000C 00020 UAB60R 3PT4S0000C 00030 UAB60R 3PT4S0000C 00040 UAB60R 3PT4S0000C 00050 UAB60R 3PT4S0000C 00060 Unit (EA) 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 4 pole Code UAB60C 4PT4S0000C 00005 UAB60C 4PT4S0000C 00010 UAB60C 4PT4S0000C 00015 UAB60C 4PT4S0000C 00020 UAB60C 4PT4S0000C 00030 UAB60C 4PT4S0000C 00040 UAB60C 4PT4S0000C 00050 UAB60C 4PT4S0000C 00060 UAB60R 4PT4S0000C 00005 UAB60R 4PT4S0000C 00010 UAB60R 4PT4S0000C 00015 UAB60R 4PT4S0000C 00020 UAB60R 4PT4S0000C 00030 UAB60R 4PT4S0000C 00040 UAB60R 4PT4S0000C 00050 UAB60R 4PT4S0000C 00060 Unit (EA) Specification Category 16 16 16 16 16 16 Screw type 16 terminal 16 connection, 16 No option, 16 50/60Hz 16 16 16 16 16 16 MCCB /M1 50℃ Model / Breaking capacity at AC380/415V UAB60C 7.5/5kA UAB60R 14/10kA Rated current 5A 10A 15A 20A 30A 40A 50A 60A 5A 10A 15A 20A 30A 40A 50A 60A 2 pole Code UAB60C 2PT5S0000C 00005 UAB60C 2PT5S0000C 00010 UAB60C 2PT5S0000C 00015 UAB60C 2PT5S0000C 00020 UAB60C 2PT5S0000C 00030 UAB60C 2PT5S0000C 00040 UAB60C 2PT5S0000C 00050 UAB60C 2PT5S0000C 00060 UAB60R 2PT5S0000C 00005 UAB60R 2PT5S0000C 00010 UAB60R 2PT5S0000C 00015 UAB60R 2PT5S0000C 00020 UAB60R 2PT5S0000C 00030 UAB60R 2PT5S0000C 00040 UAB60R 2PT5S0000C 00050 UAB60R 2PT5S0000C 00060 Unit (EA) 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 3 pole Code UAB60C 3PT5S0000C 00005 UAB60C 3PT5S0000C 00010 UAB60C 3PT5S0000C 00015 UAB60C 3PT5S0000C 00020 UAB60C 3PT5S0000C 00030 UAB60C 3PT5S0000C 00040 UAB60C 3PT5S0000C 00050 UAB60C 3PT5S0000C 00060 UAB60R 3PT5S0000C 00005 UAB60R 3PT5S0000C 00010 UAB60R 3PT5S0000C 00015 UAB60R 3PT5S0000C 00020 UAB60R 3PT5S0000C 00030 UAB60R 3PT5S0000C 00040 UAB60R 3PT5S0000C 00050 UAB60R 3PT5S0000C 00060 Unit (EA) 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 4 pole Code UAB60C 4PT5S0000C 00005 UAB60C 4PT5S0000C 00010 UAB60C 4PT5S0000C 00015 UAB60C 4PT5S0000C 00020 UAB60C 4PT5S0000C 00030 UAB60C 4PT5S0000C 00040 UAB60C 4PT5S0000C 00050 UAB60C 4PT5S0000C 00060 UAB60R 4PT5S0000C 00005 UAB60R 4PT5S0000C 00010 UAB60R 4PT5S0000C 00015 UAB60R 4PT5S0000C 00020 UAB60R 4PT5S0000C 00030 UAB60R 4PT5S0000C 00040 UAB60R 4PT5S0000C 00050 UAB60R 4PT5S0000C 00060 Unit (EA) Specification Category 16 16 16 16 16 16 Screw type 16 terminal 16 connection, 16 No option, 16 50/60Hz 16 16 16 16 16 16 MCCB /M1 Molded Case Circuit Breaker_ 45 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UAB type / 100AF | �UAB100C 14/10kA UAB100C Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated short-circuit breaking capacity IEC 60947-2 K 60947-2 Trip mechanism & Protection characteristics 2, 3, 4 IP20 A ○ overload, inst., short-circuit 5,10,15,20,30,40,50,60,75,100 AC690 AC660 DC250 6 5 7.5 10 14/10 25 5 10 50 ○ 12×In ○ ○ ○1) ○1) ○ 25,000 10,000 50/75/100 130 60 82 0.45/0.65/0.85 Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) AC600/660V, 50-60Hz AC480/500V, 50-60Hz AC440/460V, 50-60Hz Ultimate [Icu] AC380/415V, 50-60Hz (kA r.m.s.) AC220/240V, 50-60Hz DC250V DC125V Service [Ics] % of [Icu] Hydraulic magnetic Fixed thermal, Fixed instantaneous INST Direct mounting by screw Both line & load side for Switchboard Line side only for Distribution board Terminal connection Screw Mechanical operation Durability (times) Electrical operation a Width d a c b Height Dimensions 2/3/4P b (mm) c Depth d Weight (kg, breaker only) 2/3/4P Mounting Plug-in ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker ■ Accessories �Signal Auxiliary switch Trip alarm switch Shunt trip1) Under voltage trip 2) 46 1ab, Right-hand-side 2ab, Right-hand-side AUX 10A R1 AUX 10A R2 1ab, Right-hand-side ALT 10A R1 DC24V DC100-110V SHT 10A A SHT 10A C DC24V DC100-110V �UVT 10A J �UVT 10A L AC100-120V SHT 10A F AC100-120V �UVT 10A N ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. AC200-230V AC200-230V �UVT 10A P AC380-415V SHT 10A H AC380-415V �UVT 10A Q AC440-480V AC440-480V �UVT 10A R MCCB �Operating Power supply direction S type Operating Surface L type 1) handle S type Extended L type Upper TFG 10AS U4 TFG 10AL U4 Right TFG 10AS R4 TFH 10AS TFH 10AL AC/DC110V MOT 10A ADC110 3 pole MIF 10A 3 DC24V MOT 10A DC24 2 pole - Motor operator 2) Mechanical interlock Left TFG 10AS L4 TFG 10AL L4 AC/DC220V MOT 10A ADC220 4 pole MIF 10A 4 ※ 1) Available for 3P, 4P breaker. For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting Plug-in1) Structure Mounting base Connection 2C contact block2) 3C contact Conn. block barrier For both line & load side TDM 10AP CBM 10AB 2 CBM 10AB 3 CBM BARR For line side only TDF 10A - ※ 1) Available for 3P, 4P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal 3EA/SET CTB 10A 3S 2 pole TCF 10AP 2 Cage terminal block Terminal cover1) Interpole barrier2) 2EA/SET 4EA/SET CTB 10A 4S 3 pole 4 pole TCF 10AP 3 TCF 10AP 4 TQQ 10A ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 2EA, 3 pole 4EA, 4 pole 6EA ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Hydraulic magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V 표준품 주문코드 Rated current UAB100C 14/10kA 5A 10A 15A 20A 30A 40A 50A 60A 75A 100A Model / Breaking capacity at AC380/415V 표준품 주문코드 Rated current UAB100C 14/10kA 5A 10A 15A 20A 30A 40A 50A 60A 75A 100A 2 pole 3 pole Code Unit (EA) UAB100C 2PT4S0000C 00005 UAB100C 2PT4S0000C 00010 UAB100C 2PT4S0000C 00015 UAB100C 2PT4S0000C 00020 UAB100C 2PT4S0000C 00030 UAB100C 2PT4S0000C 00040 UAB100C 2PT4S0000C 00050 UAB100C 2PT4S0000C 00060 UAB100C 2PT4S0000C 00075 UAB100C 2PT4S0000C 00100 30 30 30 30 30 30 30 30 30 30 4 pole Code Unit (EA) Code UAB100C 3PT4S0000C 00005 UAB100C 3PT4S0000C 00010 UAB100C 3PT4S0000C 00015 UAB100C 3PT4S0000C 00020 UAB100C 3PT4S0000C 00030 UAB100C 3PT4S0000C 00040 UAB100C 3PT4S0000C 00050 UAB100C 3PT4S0000C 00060 UAB100C 3PT4S0000C 00075 UAB100C 3PT4S0000C 00100 20 20 20 20 20 20 20 20 20 20 UAB100C 4PT4S0000C 00005 UAB100C 4PT4S0000C 00010 UAB100C 4PT4S0000C 00015 UAB100C 4PT4S0000C 00020 UAB100C 4PT4S0000C 00030 UAB100C 4PT4S0000C 00040 UAB100C 4PT4S0000C 00050 UAB100C 4PT4S0000C 00060 UAB100C 4PT4S0000C 00075 UAB100C 4PT4S0000C 00100 Unit (EA) Specification Category 16 16 16 16 Screw type terminal 16 connection, 16 No option, 16 50/60Hz 16 16 16 MCCB /M1 50℃ 2 pole 3 pole Code Unit (EA) UAB100C 2PT5S0000C 00005 UAB100C 2PT5S0000C 00010 UAB100C 2PT5S0000C 00015 UAB100C 2PT5S0000C 00020 UAB100C 2PT5S0000C 00030 UAB100C 2PT5S0000C 00040 UAB100C 2PT5S0000C 00050 UAB100C 2PT5S0000C 00060 UAB100C 2PT5S0000C 00075 UAB100C 2PT5S0000C 00100 30 30 30 30 30 30 30 30 30 30 4 pole Code Unit (EA) Code UAB100C 3PT5S0000C 00005 UAB100C 3PT5S0000C 00010 UAB100C 3PT5S0000C 00015 UAB100C 3PT5S0000C 00020 UAB100C 3PT5S0000C 00030 UAB100C 3PT5S0000C 00040 UAB100C 3PT5S0000C 00050 UAB100C 3PT5S0000C 00060 UAB100C 3PT5S0000C 00075 UAB100C 3PT5S0000C 00100 20 20 20 20 20 20 20 20 20 20 UAB100C 4PT5S0000C 00005 UAB100C 4PT5S0000C 00010 UAB100C 4PT5S0000C 00015 UAB100C 4PT5S0000C 00020 UAB100C 4PT5S0000C 00030 UAB100C 4PT5S0000C 00040 UAB100C 4PT5S0000C 00050 UAB100C 4PT5S0000C 00060 UAB100C 4PT5S0000C 00075 UAB100C 4PT5S0000C 00100 Unit (EA) Specification Category 16 16 16 16 Screw type terminal 16 connection, 16 No option, 16 50/60Hz 16 16 16 MCCB /M1 Molded Case Circuit Breaker_ 47 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UAB type / 100AF | �UAB100R 25kA �UAB100S 30kA UAB100S UAB100R Number of poles (P) 2, 3, 4 Degree of protection (with terminal cover) IP20 Utilization category A Suitability of isolation ○ overload, inst., short-circuit Protection 15,16,20,25,30,32,40,50,60,63,75,80,100 Rated current (A) AC690 Rated insulation voltage [Ui] (V) Rating AC660 Rated operational voltage [Ue] (V) DC250 Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit breaking capacity Ultimate [Icu] (kA r.m.s.) IEC 60947-2 K 60947-2 7.5 10 AC480/500V, 50-60Hz 7.5 14 AC440/460V, 50-60Hz 21 25 AC380/415V, 50-60Hz 25 30 AC220/240V, 50-60Hz 42 50 DC250V 10 14 DC125V 15 20 Service [Ics] % of [Icu] Trip mechanism Thermal & Protection magnetic characteristics 25 Fixed thermal, Fixed instantaneous Adjustable thermal, Fixed instantaneous ○ INST 15-32A: 20×In, 40-100A: 10×In LTD (0.8-0.9-1)×In 2) INST 15-32A: 20×In, 40-100A: 10×In ○ Direct mounting by screw Mounting Plug-in DIN-rail Terminal connection Durability (times) Both line & load side for Switchboard Line side only ○ for Distribution board ○1) with DIN-rail adaptor ○ ○1) ○ Screw Mechanical operation 25,000 Electrical operation 10,000 a a Dimensions (mm) 6 AC600/660V, 50-60Hz b d c 2/3/4P Width 50/75/100 b Height 130 c Depth 60 d Weight (kg, breaker only) 2/3/4P 82 0.6/0.78/0.96 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 2) Available for 3P, 4P breaker 48 MCCB ■ Accessories �Signal 1ab, Right-hand-side Auxiliary switch Trip alarm switch Shunt trip 1) Under voltage trip 2) 1ab, Left-hand-side AUX 10UA R1 AUX 10UA L1 1ab, Right-hand-side 1ab, Left-hand-side ALT 10UA R1 ALT 10UA L1 DC24V DC100-110V AC100-120V AC200-230V AC380-415V SHT 10UA A SHT 10UA C SHT 10UA F SHT 10UA H SHT 10UA B SHT 10UA D DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V UVT 10UA J UVT 10UA L UVT 10UA N UVT 10UA P UVT 10UA Q UVT 10UA R AC440-480V ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Operating Upper Right Left S type TFG 10UAS U4 TFG 10UAS R4 TFG 10UAS L4 L type TFG 10UAL U4 - TFG 10UAL L4 Power supply direction Operating Surface handle1) Extended TFH 10UAS S type TFH 10UAL L type Motor operator 2) DC24V AC/DC110V AC/DC220V MOT 10UA DC24 MOT 10UA ADC110 MOT 10UA ADC220 2 pole 3 pole 4 pole - MIF 10UA 3 MIF 10UA 4 Mechanical interlock ※ 1) Available for 3P, 4P breaker. For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting DRA 10UA DIN-rail adaptor Structure For both line & load side For line side only TDM 10AP TDF 10A Plug-in1) Connection 2C contact CBM 10AB 2 - 2) CBM 10AB 3 - CBM BARR - Mounting base block 3C contact Conn. block barrier ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal 3EA/SET Cage terminal block Terminal cover CTB 10A 3S 1) Interpole barrier 2) 4EA/SET 2EA/SET CTB 10A 4S 2 pole 3 pole 4 pole TCF 10AP 2 TCF 10AP 3 TCF 10AP 4 TQQ 10A ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 2EA, 3 pole 4EA, 4 pole 6EA Molded Case Circuit Breaker_ 49 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UAB100R 25kA UAB100S 30kA 2 pole 3 pole 4 pole Rated current Code Unit (EA) Code Unit (EA) 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A UAB100R 2PT4S0000C 00015 UAB100R 2PT4S0000C 00016 UAB100R 2PT4S0000C 00020 UAB100R 2PT4S0000C 00025 UAB100R 2PT4S0000C 00030 UAB100R 2PT4S0000C 00032 UAB100R 2PT4S0000C 00040 UAB100R 2PT4S0000C 00050 UAB100R 2PT4S0000C 00060 UAB100R 2PT4S0000C 00063 UAB100R 2PT4S0000C 00075 UAB100R 2PT4S0000C 00080 UAB100R 2PT4S0000C 00100 UAB100S 2PT4S0000C 00015 UAB100S 2PT4S0000C 00016 UAB100S 2PT4S0000C 00020 UAB100S 2PT4S0000C 00025 UAB100S 2PT4S0000C 00030 UAB100S 2PT4S0000C 00032 UAB100S 2PT4S0000C 00040 UAB100S 2PT4S0000C 00050 UAB100S 2PT4S0000C 00060 UAB100S 2PT4S0000C 00063 UAB100S 2PT4S0000C 00075 UAB100S 2PT4S0000C 00080 UAB100S 2PT4S0000C 00100 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 UAB100R 3PT4S0000C 00015 UAB100R 3PT4S0000C 00016 UAB100R 3PT4S0000C 00020 UAB100R 3PT4S0000C 00025 UAB100R 3PT4S0000C 00030 UAB100R 3PT4S0000C 00032 UAB100R 3PT4S0000C 00040 UAB100R 3PT4S0000C 00050 UAB100R 3PT4S0000C 00060 UAB100R 3PT4S0000C 00063 UAB100R 3PT4S0000C 00075 UAB100R 3PT4S0000C 00080 UAB100R 3PT4S0000C 00100 UAB100S 3PT4S0000C 00015 UAB100S 3PT4S0000C 00016 UAB100S 3PT4S0000C 00020 UAB100S 3PT4S0000C 00025 UAB100S 3PT4S0000C 00030 UAB100S 3PT4S0000C 00032 UAB100S 3PT4S0000C 00040 UAB100S 3PT4S0000C 00050 UAB100S 3PT4S0000C 00060 UAB100S 3PT4S0000C 00063 UAB100S 3PT4S0000C 00075 UAB100S 3PT4S0000C 00080 UAB100S 3PT4S0000C 00100 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 Rated current Code Unit (EA) Code Unit (EA) 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A UAB100R 2PT5S0000C 00015 UAB100R 2PT5S0000C 00016 UAB100R 2PT5S0000C 00020 UAB100R 2PT5S0000C 00025 UAB100R 2PT5S0000C 00030 UAB100R 2PT5S0000C 00032 UAB100R 2PT5S0000C 00040 UAB100R 2PT5S0000C 00050 UAB100R 2PT5S0000C 00060 UAB100R 2PT5S0000C 00063 UAB100R 2PT5S0000C 00075 UAB100R 2PT5S0000C 00080 UAB100R 2PT5S0000C 00100 UAB100S 2PT5S0000C 00015 UAB100S 2PT5S0000C 00016 UAB100S 2PT5S0000C 00020 UAB100S 2PT5S0000C 00025 UAB100S 2PT5S0000C 00030 UAB100S 2PT5S0000C 00032 UAB100S 2PT5S0000C 00040 UAB100S 2PT5S0000C 00050 UAB100S 2PT5S0000C 00060 UAB100S 2PT5S0000C 00063 UAB100S 2PT5S0000C 00075 UAB100S 2PT5S0000C 00080 UAB100S 2PT5S0000C 00100 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 UAB100R 3PT5S0000C 00015 UAB100R 3PT5S0000C 00016 UAB100R 3PT5S0000C 00020 UAB100R 3PT5S0000C 00025 UAB100R 3PT5S0000C 00030 UAB100R 3PT5S0000C 00032 UAB100R 3PT5S0000C 00040 UAB100R 3PT5S0000C 00050 UAB100R 3PT5S0000C 00060 UAB100R 3PT5S0000C 00063 UAB100R 3PT5S0000C 00075 UAB100R 3PT5S0000C 00080 UAB100R 3PT5S0000C 00100 UAB100S 3PT5S0000C 00015 UAB100S 3PT5S0000C 00016 UAB100S 3PT5S0000C 00020 UAB100S 3PT5S0000C 00025 UAB100S 3PT5S0000C 00030 UAB100S 3PT5S0000C 00032 UAB100S 3PT5S0000C 00040 UAB100S 3PT5S0000C 00050 UAB100S 3PT5S0000C 00060 UAB100S 3PT5S0000C 00063 UAB100S 3PT5S0000C 00075 UAB100S 3PT5S0000C 00080 UAB100S 3PT5S0000C 00100 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 Code UAB100R 4PT4S0000C 00015 UAB100R 4PT4S0000C 00016 UAB100R 4PT4S0000C 00020 UAB100R 4PT4S0000C 00025 UAB100R 4PT4S0000C 00030 UAB100R 4PT4S0000C 00032 UAB100R 4PT4S0000C 00040 UAB100R 4PT4S0000C 00050 UAB100R 4PT4S0000C 00060 UAB100R 4PT4S0000C 00063 UAB100R 4PT4S0000C 00075 UAB100R 4PT4S0000C 00080 UAB100R 4PT4S0000C 00100 UAB100S 4PT4S0000C 00015 UAB100S 4PT4S0000C 00016 UAB100S 4PT4S0000C 00020 UAB100S 4PT4S0000C 00025 UAB100S 4PT4S0000C 00030 UAB100S 4PT4S0000C 00032 UAB100S 4PT4S0000C 00040 UAB100S 4PT4S0000C 00050 UAB100S 4PT4S0000C 00060 UAB100S 4PT4S0000C 00063 UAB100S 4PT4S0000C 00075 UAB100S 4PT4S0000C 00080 UAB100S 4PT4S0000C 00100 Unit (EA) Specification Category 16 16 16 16 16 16 16 16 16 16 16 16 Screw type terminal 16 connection, 16 No option, 16 50/60Hz 16 16 16 16 16 16 16 16 16 16 16 MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UAB100R 25kA UAB100S 30kA 50 2 pole 3 pole 4 pole Code UAB100R 4PT5S0000C 00015 UAB100R 4PT5S0000C 00016 UAB100R 4PT5S0000C 00020 UAB100R 4PT5S0000C 00025 UAB100R 4PT5S0000C 00030 UAB100R 4PT5S0000C 00032 UAB100R 4PT5S0000C 00040 UAB100R 4PT5S0000C 00050 UAB100R 4PT5S0000C 00060 UAB100R 4PT5S0000C 00063 UAB100R 4PT5S0000C 00075 UAB100R 4PT5S0000C 00080 UAB100R 4PT5S0000C 00100 UAB100S 4PT5S0000C 00015 UAB100S 4PT5S0000C 00016 UAB100S 4PT5S0000C 00020 UAB100S 4PT5S0000C 00025 UAB100S 4PT5S0000C 00030 UAB100S 4PT5S0000C 00032 UAB100S 4PT5S0000C 00040 UAB100S 4PT5S0000C 00050 UAB100S 4PT5S0000C 00060 UAB100S 4PT5S0000C 00063 UAB100S 4PT5S0000C 00075 UAB100S 4PT5S0000C 00080 UAB100S 4PT5S0000C 00100 Unit (EA) Specification Category 16 16 16 16 16 16 16 16 16 16 16 16 Screw type terminal 16 connection, 16 No option, 16 50/60Hz 16 16 16 16 16 16 16 16 16 16 16 MCCB /M2 MCCB �Adjustable thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UAB100R 25kA UAB100S 30kA Rated current 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 3 pole Code UAB100R 3PT4S0000C 00015F UAB100R 3PT4S0000C 00016F UAB100R 3PT4S0000C 00020F UAB100R 3PT4S0000C 00025F UAB100R 3PT4S0000C 00030F UAB100R 3PT4S0000C 00032F UAB100R 3PT4S0000C 00040F UAB100R 3PT4S0000C 00050F UAB100R 3PT4S0000C 00060F UAB100R 3PT4S0000C 00063F UAB100R 3PT4S0000C 00075F UAB100R 3PT4S0000C 00080F UAB100R 3PT4S0000C 00100F UAB100S 3PT4S0000C 00015F UAB100S 3PT4S0000C 00016F UAB100S 3PT4S0000C 00020F UAB100S 3PT4S0000C 00025F UAB100S 3PT4S0000C 00030F UAB100S 3PT4S0000C 00032F UAB100S 3PT4S0000C 00040F UAB100S 3PT4S0000C 00050F UAB100S 3PT4S0000C 00060F UAB100S 3PT4S0000C 00063F UAB100S 3PT4S0000C 00075F UAB100S 3PT4S0000C 00080F UAB100S 3PT4S0000C 00100F 4 pole Unit (EA) 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 Code UAB100R 4PT4S0000C 00015F UAB100R 4PT4S0000C 00016F UAB100R 4PT4S0000C 00020F UAB100R 4PT4S0000C 00025F UAB100R 4PT4S0000C 00030F UAB100R 4PT4S0000C 00032F UAB100R 4PT4S0000C 00040F UAB100R 4PT4S0000C 00050F UAB100R 4PT4S0000C 00060F UAB100R 4PT4S0000C 00063F UAB100R 4PT4S0000C 00075F UAB100R 4PT4S0000C 00080F UAB100R 4PT4S0000C 00100F UAB100S 4PT4S0000C 00015F UAB100S 4PT4S0000C 00016F UAB100S 4PT4S0000C 00020F UAB100S 4PT4S0000C 00025F UAB100S 4PT4S0000C 00030F UAB100S 4PT4S0000C 00032F UAB100S 4PT4S0000C 00040F UAB100S 4PT4S0000C 00050F UAB100S 4PT4S0000C 00060F UAB100S 4PT4S0000C 00063F UAB100S 4PT4S0000C 00075F UAB100S 4PT4S0000C 00080F UAB100S 4PT4S0000C 00100F Unit (EA) 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UAB100R 25kA UAB100S 30kA Rated current 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 3 pole Code UAB100R 3PT5S0000C 00015F UAB100R 3PT5S0000C 00016F UAB100R 3PT5S0000C 00020F UAB100R 3PT5S0000C 00025F UAB100R 3PT5S0000C 00030F UAB100R 3PT5S0000C 00032F UAB100R 3PT5S0000C 00040F UAB100R 3PT5S0000C 00050F UAB100R 3PT5S0000C 00060F UAB100R 3PT5S0000C 00063F UAB100R 3PT5S0000C 00075F UAB100R 3PT5S0000C 00080F UAB100R 3PT5S0000C 00100F UAB100S 3PT5S0000C 00015F UAB100S 3PT5S0000C 00016F UAB100S 3PT5S0000C 00020F UAB100S 3PT5S0000C 00025F UAB100S 3PT5S0000C 00030F UAB100S 3PT5S0000C 00032F UAB100S 3PT5S0000C 00040F UAB100S 3PT5S0000C 00050F UAB100S 3PT5S0000C 00060F UAB100S 3PT5S0000C 00063F UAB100S 3PT5S0000C 00075F UAB100S 3PT5S0000C 00080F UAB100S 3PT5S0000C 00100F 4 pole Unit (EA) 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 Code UAB100R 4PT5S0000C 00015F UAB100R 4PT5S0000C 00016F UAB100R 4PT5S0000C 00020F UAB100R 4PT5S0000C 00025F UAB100R 4PT5S0000C 00030F UAB100R 4PT5S0000C 00032F UAB100R 4PT5S0000C 00040F UAB100R 4PT5S0000C 00050F UAB100R 4PT5S0000C 00060F UAB100R 4PT5S0000C 00063F UAB100R 4PT5S0000C 00075F UAB100R 4PT5S0000C 00080F UAB100R 4PT5S0000C 00100F UAB100S 4PT5S0000C 00015F UAB100S 4PT5S0000C 00016F UAB100S 4PT5S0000C 00020F UAB100S 4PT5S0000C 00025F UAB100S 4PT5S0000C 00030F UAB100S 4PT5S0000C 00032F UAB100S 4PT5S0000C 00040F UAB100S 4PT5S0000C 00050F UAB100S 4PT5S0000C 00060F UAB100S 4PT5S0000C 00063F UAB100S 4PT5S0000C 00075F UAB100S 4PT5S0000C 00080F UAB100S 4PT5S0000C 00100F Unit (EA) 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 Molded Case Circuit Breaker_ 51 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UCB type / 50AF | �UCB50R 30/25kA UCB50R Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated short-circuit breaking capacity IEC 60947-2 K 60947-2 Trip mechanism & Protection characteristics 2, 3, 4 IP20 A ○ overload, inst., short-circuit 15,20,30,40,50 AC690 AC660 DC250 6 10 14 25 30/25 50 14 20 50 ○ Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) AC600/660V, 50-60Hz AC480/500V, 50-60Hz AC440/460V, 50-60Hz Ultimate AC380/415V, 50-60Hz [Icu] (kA r.m.s.) AC220/240V, 50-60Hz DC250V DC125V Service [Ics] % of [Icu] Thermal magnetic Fixed thermal, Fixed instantaneous INST 10×In ○ ○1) ○1) ○1) ○ Direct mounting by screw Both line & load side for Switchboard Line side only for Distribution board Terminal connection Screw Mechanical operation Durability (times) Electrical operation a Width d a c b Height Dimensions 2/3/4P b (mm) c Depth d Weight (kg, breaker only) 2/3/4P Mounting Plug-in 25,000 10,000 60/90/120 155 60 84.5 0.7/1.0/1.2 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker ■ Accessories �Signal Auxiliary switch Trip alarm switch Shunt trip1) Under voltage trip 2) 1ab, Left-hand-side AUX 10B L1 1ab, Left-hand-side ALT 10B L1 DC24V SHT 10B A DC24V UVT 10B J DC100-110V SHT 10B C DC100-110V UVT 10B L AC100-120V SHT 10B F AC100-120V UVT 10B N ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) 52 AC200-230V AC200-230V UVT 10B P AC380-415V SHT 10B H AC380-415V UVT 10B Q AC440-480V AC440-480V UVT 10B R MCCB �Operating Power supply direction S type Operating Surface L type 1) handle S type Extended L type Upper TFG 10BS U4 TFG 10BL U4 Right TFG 10BS R4 TFH 10BS TFH 10BL AC/DC110V MOT 10B ADC110 3 pole MIF 10UF 3 DC24V MOT 10B DC24 2 pole - Motor operator 2) Mechanical interlock Left TFG 10BS L4 TFG 10BL L4 AC/DC220V MOT 10B ADC220 4 pole MIF 10UF 4 ※ 1) Available for 3P, 4P breaker. For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting Plug-in1) Structure Mounting base Connection 2C contact block2) 3C contact Conn. block barrier For both line & load side TDM 10BP CBM 10AB 2 CBM 10AB 3 CBM BARR For line side only TDF 10B - ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal 3EA/SET CTB 10B 3S 2 pole TCF 10BP 2 Cage terminal block Terminal cover1) Interpole barrier 2) 2EA/SET 4EA/SET CTB 10B 4S 3 pole TCF 10BP 3 TQQ 10B 4 pole TCF 10BP 4 ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 2EA, 3 pole 4EA, 4 pole 6EA ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V 표준품 주문코드 UCB50R 30/25kA Rated current 2 pole Code 3 pole Unit (EA) 4 pole Code Unit (EA) Code Unit (EA) 15A UCB50R 2PT4S0000C 00015 16 UCB50R 3PT4S0000C 00015 10 UCB50R 4PT4S0000C 00015 8 20A UCB50R 2PT4S0000C 00020 16 UCB50R 3PT4S0000C 00020 10 UCB50R 4PT4S0000C 00020 8 30A UCB50R 2PT4S0000C 00030 16 UCB50R 3PT4S0000C 00030 10 UCB50R 4PT4S0000C 00030 8 40A UCB50R 2PT4S0000C 00040 16 UCB50R 3PT4S0000C 00040 10 UCB50R 4PT4S0000C 00040 8 50A UCB50R 2PT4S0000C 00050 16 UCB50R 3PT4S0000C 00050 10 UCB50R 4PT4S0000C 00050 8 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M1 50℃ Model / Breaking capacity at AC380/415V 표준품 주문코드 UCB50R 30/25kA 2 pole 3 pole 4 pole Rated current Code 15A UCB50R 2PT5S0000C 00015 16 UCB50R 3PT5S0000C 00015 10 UCB50R 4PT5S0000C 00015 8 20A UCB50R 2PT5S0000C 00020 16 UCB50R 3PT5S0000C 00020 10 UCB50R 4PT5S0000C 00020 8 30A UCB50R 2PT5S0000C 00030 16 UCB50R 3PT5S0000C 00030 10 UCB50R 4PT5S0000C 00030 8 40A UCB50R 2PT5S0000C 00040 16 UCB50R 3PT5S0000C 00040 10 UCB50R 4PT5S0000C 00040 8 50A UCB50R 2PT5S0000C 00050 16 UCB50R 3PT5S0000C 00050 10 UCB50R 4PT5S0000C 00050 8 Unit (EA) Code Unit (EA) Code Unit (EA) Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M1 Molded Case Circuit Breaker_ 53 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UCB type / 50AF | �UCB50H 42kA �UCB50L 50kA UCB50H �2, 3, 4 Number of poles (P) Degree of protection (with terminal cover) IP20 Utilization category A ○ Suitability of isolation Protection overload, inst., short-circuit Rated current (A) 15,16,20,25,30,32,40,50 Rated insulation voltage [Ui] (V) Rating UCB50L AC690 AC660 Rated operational voltage [Ue] (V) DC250 Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit breaking capacity Ultimate [Icu] (kA r.m.s.) IEC 60947-2 K 60947-2 AC600/660V, 50-60Hz 20 25 AC480/500V, 50-60Hz 30 35 AC440/460V, 50-60Hz 42 50 AC380/415V, 50-60Hz 42 50 AC220/240V, 50-60Hz 85 100 DC250V 25 40 DC125V 40 60 Service [Ics] % of [Icu] Trip mechanism Thermal magnetic & Protection characteristics 50 Fixed thermal, Fixed instantaneous Adjustable thermal, Fixed instantaneous ○ INST 15-32A: 15×In, 40-50A: 10×In LTD (0.8-0.9-1)×In INST 15-32A: 15×In, 40-50A: 10×In ○ Direct mounting by screw Mounting Plug-in Terminal connection Durability (times) Both line & load side for Switchboard Line side only ○1) for Distribution board ○1) Screw ○ Mechanical operation b d c 2/3/4P 10,000 a Width 902)/90/120 b Height 155 c Depth 60 d Weight (kg, breaker only) 2/3/4P ○1) 25,000 Electrical operation a Dimensions (mm) 6 84.5 0.9/1.0/1.3 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 2) �2P breaker has same dimension as 3P breaker, but the middle pole is removed. 54 MCCB ■ Accessories �Signal 1ab, Right-hand-side 2ab, Right-hand-side Auxiliary switch Trip alarm switch 1) Shunt trip Under voltage trip 2) AUX 12FG R1 AUX 12FG R2 1ab, Right-hand-side 1ab, Left-hand-side ALT 12FG R1 ALT 12FG L1 DC24V DC100-110V AC100-120V AC200-230V AC380-415V SHT 12FG A SHT 12FG C SHT 12FG F SHT 12FG H SHT 12FG B SHT 12FG D DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V UVT 12FG J UVT 12FG L UVT 12FG N UVT 12FG P UVT 12FG Q UVT 12FG R AC440-480V ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Operating Upper Right Left S type TFG 10UFS U4 TFG 10UFS R4 TFG 10UFS L4 L type TFG 10UFL U4 - TFG 10UFL L4 Power supply direction Operating Surface handle1) Extended TFH 10UFS S type TFH 10UFL L type Motor operator 2) DC24V AC/DC110V AC/DC220V MOT 10F DC24 MOT 10F ADC110 MOT 10F ADC220 Mechanical interlock 2 pole 3 pole 4 pole - MIF 10UF 3 MIF 10UF 4 ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting Structure Mounting base Plug-in1) Connection 2C contact block 2) 3C contact Conn. block barrier For both line & load side For line side only TDM 10BP TDF 10B CBM 10AB 2 - CBM 10AB 3 - CBM BARR - ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal Cage terminal block Terminal cover1) Interpole barrier2) 2EA/SET 3EA/SET 4EA/SET CTB 10B 3S CTB 10B 4S 2 pole 3 pole 4 pole TCF 10FP 3 TCF 10FP 3 TCF 10FP 4 TQQ 12FG ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 4EA, 3 pole 4EA, 4 pole 6EA Molded Case Circuit Breaker_ 55 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V Rated current 2 pole 3 pole 4 pole Code Unit (EA) Code Unit (EA) 15A UCB50H 2PT4S0000C 00015 8 UCB50H 3PT4S0000C 00015 8 UCB50H 4PT4S0000C 00015 6 16A UCB50H 2PT4S0000C 00016 8 UCB50H 3PT4S0000C 00016 8 UCB50H 4PT4S0000C 00016 6 Code Unit (EA) 20A UCB50H 2PT4S0000C 00020 8 UCB50H 3PT4S0000C 00020 8 UCB50H 4PT4S0000C 00020 6 UCB50H 25A UCB50H 2PT4S0000C 00025 8 UCB50H 3PT4S0000C 00025 8 UCB50H 4PT4S0000C 00025 6 42kA 30A UCB50H 2PT4S0000C 00030 8 UCB50H 3PT4S0000C 00030 8 UCB50H 4PT4S0000C 00030 6 32A UCB50H 2PT4S0000C 00032 8 UCB50H 3PT4S0000C 00032 8 UCB50H 4PT4S0000C 00032 6 40A UCB50H 2PT4S0000C 00040 8 UCB50H 3PT4S0000C 00040 8 UCB50H 4PT4S0000C 00040 6 50A UCB50H 2PT4S0000C 00050 8 UCB50H 3PT4S0000C 00050 8 UCB50H 4PT4S0000C 00050 6 15A UCB50L 2PT4S0000C 00015 8 UCB50L 3PT4S0000C 00015 8 UCB50L 4PT4S0000C 00015 6 16A UCB50L 2PT4S0000C 00016 8 UCB50L 3PT4S0000C 00016 8 UCB50L 4PT4S0000C 00016 6 20A UCB50L 2PT4S0000C 00020 8 UCB50L 3PT4S0000C 00020 8 UCB50L 4PT4S0000C 00020 6 UCB50L 25A UCB50L 2PT4S0000C 00025 8 UCB50L 3PT4S0000C 00025 8 UCB50L 4PT4S0000C 00025 6 50kA 30A UCB50L 2PT4S0000C 00030 8 UCB50L 3PT4S0000C 00030 8 UCB50L 4PT4S0000C 00030 6 32A UCB50L 2PT4S0000C 00032 8 UCB50L 3PT4S0000C 00032 8 UCB50L 4PT4S0000C 00032 6 40A UCB50L 2PT4S0000C 00040 8 UCB50L 3PT4S0000C 00040 8 UCB50L 4PT4S0000C 00040 6 50A UCB50L 2PT4S0000C 00050 8 UCB50L 3PT4S0000C 00050 8 UCB50L 4PT4S0000C 00050 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V 56 Rated current 2 pole 3 pole 4 pole Code Unit (EA) Code Unit (EA) 15A UCB50H 2PT5S0000C 00015 8 UCB50H 3PT5S0000C 00015 8 UCB50H 4PT5S0000C 00015 6 16A UCB50H 2PT5S0000C 00016 8 UCB50H 3PT5S0000C 00016 8 UCB50H 4PT5S0000C 00016 6 20A UCB50H 2PT5S0000C 00020 8 UCB50H 3PT5S0000C 00020 8 UCB50H 4PT5S0000C 00020 6 UCB50H 25A UCB50H 2PT5S0000C 00025 8 UCB50H 3PT5S0000C 00025 8 UCB50H 4PT5S0000C 00025 6 42kA 30A UCB50H 2PT5S0000C 00030 8 UCB50H 3PT5S0000C 00030 8 UCB50H 4PT5S0000C 00030 6 32A UCB50H 2PT5S0000C 00032 8 UCB50H 3PT5S0000C 00032 8 UCB50H 4PT5S0000C 00032 6 40A UCB50H 2PT5S0000C 00040 8 UCB50H 3PT5S0000C 00040 8 UCB50H 4PT5S0000C 00040 6 50A UCB50H 2PT5S0000C 00050 8 UCB50H 3PT5S0000C 00050 8 UCB50H 4PT5S0000C 00050 6 15A UCB50L 2PT5S0000C 00015 8 UCB50L 3PT5S0000C 00015 8 UCB50L 4PT5S0000C 00015 6 16A UCB50L 2PT5S0000C 00016 8 UCB50L 3PT5S0000C 00016 8 UCB50L 4PT5S0000C 00016 6 Code Unit (EA) 20A UCB50L 2PT5S0000C 00020 8 UCB50L 3PT5S0000C 00020 8 UCB50L 4PT5S0000C 00020 6 UCB50L 25A UCB50L 2PT5S0000C 00025 8 UCB50L 3PT5S0000C 00025 8 UCB50L 4PT5S0000C 00025 6 50kA 30A UCB50L 2PT5S0000C 00030 8 UCB50L 3PT5S0000C 00030 8 UCB50L 4PT5S0000C 00030 6 32A UCB50L 2PT5S0000C 00032 8 UCB50L 3PT5S0000C 00032 8 UCB50L 4PT5S0000C 00032 6 40A UCB50L 2PT5S0000C 00040 8 UCB50L 3PT5S0000C 00040 8 UCB50L 4PT5S0000C 00040 6 50A UCB50L 2PT5S0000C 00050 8 UCB50L 3PT5S0000C 00050 8 UCB50L 4PT5S0000C 00050 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 MCCB �Adjustable thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V Rated current 2 pole Code 3 pole Unit (EA) Code 4 pole Unit (EA) Code Unit (EA) 15A UCB50H 2PT4S0000C 00015F 8 UCB50H 3PT4S0000C 00015F 8 UCB50H 4PT4S0000C 00015F 6 16A UCB50H 2PT4S0000C 00016F 8 UCB50H 3PT4S0000C 00016F 8 UCB50H 4PT4S0000C 00016F 6 20A UCB50H 2PT4S0000C 00020F 8 UCB50H 3PT4S0000C 00020F 8 UCB50H 4PT4S0000C 00020F 6 UCB50H 25A UCB50H 2PT4S0000C 00025F 8 UCB50H 3PT4S0000C 00025F 8 UCB50H 4PT4S0000C 00025F 6 42kA 30A UCB50H 2PT4S0000C 00030F 8 UCB50H 3PT4S0000C 00030F 8 UCB50H 4PT4S0000C 00030F 6 32A UCB50H 2PT4S0000C 00032F 8 UCB50H 3PT4S0000C 00032F 8 UCB50H 4PT4S0000C 00032F 6 40A UCB50H 2PT4S0000C 00040F 8 UCB50H 3PT4S0000C 00040F 8 UCB50H 4PT4S0000C 00040F 6 50A UCB50H 2PT4S0000C 00050F 8 UCB50H 3PT4S0000C 00050F 8 UCB50H 4PT4S0000C 00050F 6 15A UCB50L 2PT4S0000C 00015F 8 UCB50L 3PT4S0000C 00015F 8 UCB50L 4PT4S0000C 00015F 6 16A UCB50L 2PT4S0000C 00016F 8 UCB50L 3PT4S0000C 00016F 8 UCB50L 4PT4S0000C 00016F 6 20A UCB50L 2PT4S0000C 00020F 8 UCB50L 3PT4S0000C 00020F 8 UCB50L 4PT4S0000C 00020F 6 UCB50L 25A UCB50L 2PT4S0000C 00025F 8 UCB50L 3PT4S0000C 00025F 8 UCB50L 4PT4S0000C 00025F 6 50kA 30A UCB50L 2PT4S0000C 00030F 8 UCB50L 3PT4S0000C 00030F 8 UCB50L 4PT4S0000C 00030F 6 32A UCB50L 2PT4S0000C 00032F 8 UCB50L 3PT4S0000C 00032F 8 UCB50L 4PT4S0000C 00032F 6 40A UCB50L 2PT4S0000C 00040F 8 UCB50L 3PT4S0000C 00040F 8 UCB50L 4PT4S0000C 00040F 6 50A UCB50L 2PT4S0000C 00050F 8 UCB50L 3PT4S0000C 00050F 8 UCB50L 4PT4S0000C 00050F 6 3 pole 4 pole Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V Rated current 2 pole Code Unit (EA) Code Unit (EA) 15A UCB50H 2PT5S0000C 00015F 8 UCB50H 3PT5S0000C 00015F 8 UCB50H 4PT5S0000C 00015F 6 16A UCB50H 2PT5S0000C 00016F 20A UCB50H 2PT5S0000C 00020F 8 UCB50H 3PT5S0000C 00016F 8 UCB50H 4PT5S0000C 00016F 6 8 UCB50H 3PT5S0000C 00020F 8 UCB50H 4PT5S0000C 00020F 6 UCB50H 25A 42kA 30A UCB50H 2PT5S0000C 00025F 8 UCB50H 3PT5S0000C 00025F 8 UCB50H 4PT5S0000C 00025F 6 UCB50H 2PT5S0000C 00030F 8 UCB50H 3PT5S0000C 00030F 8 UCB50H 4PT5S0000C 00030F 6 32A UCB50H 2PT5S0000C 00032F 8 UCB50H 3PT5S0000C 00032F 8 UCB50H 4PT5S0000C 00032F 6 40A UCB50H 2PT5S0000C 00040F 8 UCB50H 3PT5S0000C 00040F 8 UCB50H 4PT5S0000C 00040F 6 50A UCB50H 2PT5S0000C 00050F 8 UCB50H 3PT5S0000C 00050F 8 UCB50H 4PT5S0000C 00050F 6 15A UCB50L 2PT5S0000C 00015F 8 UCB50L 3PT5S0000C 00015F 8 UCB50L 4PT5S0000C 00015F 6 16A UCB50L 2PT5S0000C 00016F 8 UCB50L 3PT5S0000C 00016F 8 UCB50L 4PT5S0000C 00016F 6 Code Unit (EA) 20A UCB50L 2PT5S0000C 00020F 8 UCB50L 3PT5S0000C 00020F 8 UCB50L 4PT5S0000C 00020F 6 UCB50L 25A UCB50L 2PT5S0000C 00025F 8 UCB50L 3PT5S0000C 00025F 8 UCB50L 4PT5S0000C 00025F 6 50kA 30A UCB50L 2PT5S0000C 00030F 8 UCB50L 3PT5S0000C 00030F 8 UCB50L 4PT5S0000C 00030F 6 32A UCB50L 2PT5S0000C 00032F 8 UCB50L 3PT5S0000C 00032F 8 UCB50L 4PT5S0000C 00032F 6 40A UCB50L 2PT5S0000C 00040F 8 UCB50L 3PT5S0000C 00040F 8 UCB50L 4PT5S0000C 00040F 6 50A UCB50L 2PT5S0000C 00050F 8 UCB50L 3PT5S0000C 00050F 8 UCB50L 4PT5S0000C 00050F 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 Molded Case Circuit Breaker_ 57 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UCB type / 100AF | �UCB100R 30/25kA �UCB100S 42/36kA UCB100R UCB100S Number of poles (P) 2, 3, 4 Degree of protection (with terminal cover) IP20 Utilization category A Suitability of isolation ○ Protection overload, inst., short-circuit Rated current (A) 15,16,20,25,30,32,40,50,60,63,75,80,100 Rated insulation voltage [Ui] (V) Rating AC690 AC660 Rated operational voltage [Ue] (V) DC250 Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit breaking capacity Ultimate [Icu] (kA r.m.s.) IEC 60947-2 K 60947-2 AC600/660V, 50-60Hz 10 18 AC480/500V, 50-60Hz 14 25 AC440/460V, 50-60Hz 25 35 AC380/415V, 50-60Hz 30/25 42/36 AC220/240V, 50-60Hz 50 65 DC250V 14 18 DC125V 20 25 Service [Ics] % of [Icu] Trip mechanism Thermal magnetic & Protection characteristics 75 Fixed thermal, Fixed instantaneous Adjustable thermal, Fixed instantaneous ○ INST 10×In LTD (0.8-0.9-1)×In INST 10×In ○ Direct mounting by screw Mounting Plug-in Terminal connection Durability (times) ○1) for Distribution board ○1) Screw ○ 25,000 Electrical operation b d c 2/3/4P 10,000 a Width 60/90/120 b Height 155 c Depth 60 d Weight (kg, breaker only) ○1) Both line & load side for Switchboard Line side only Mechanical operation a Dimensions (mm) 6 2/3/4P 84.5 0.7/1.0/1.2 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 58 MCCB ■ Accessories �Signal 1ab, Left-hand-side Auxiliary switch AUX 10B L1 1ab, Left-hand-side Trip alarm switch Shunt trip ALT 10B L1 1) Under voltage trip 2) DC24V DC100-110V AC100-120V SHT 10B A SHT 10B C SHT 10B F AC200-230V AC380-415V AC440-480V DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V UVT 10B J UVT 10B L UVT 10B N UVT 10B P UVT 10B Q UVT 10B R SHT 10B H ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Operating Upper Right Left S type TFG 10BS U4 TFG 10BS R4 TFG 10BS L4 L type TFG 10BL U4 - TFG 10BL L4 Power supply direction Operating Surface handle1) Extended S type TFH 10BS L type TFH 10BL Motor operator 2) DC24V AC/DC110V AC/DC220V MOT 10B DC24 MOT 10B ADC110 MOT 10B ADC220 Mechanical interlock 2 pole 3 pole 4 pole - MIF 10UF 3 MIF 10UF 4 ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting For both line & load side For line side only TDM 10BP TDF 10B Plug-in1) Connection 2C contact CBM 10AB 2 - 2) CBM 10AB 3 - CBM BARR - Structure Mounting base block 3C contact Conn. block barrier ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal 3EA/SET Cage terminal block CTB 10B 3S Terminal cover1) Interpole barrier2) 4EA/SET 2EA/SET CTB 10B 4S 2 pole 3 pole 4 pole TCF 10BP 2 TCF 10BP 3 TCF 10BP 4 TQQ 10B ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 2EA, 3 pole 4EA, 4 pole 6EA Molded Case Circuit Breaker_ 59 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UCB100R 30/25kA UCB100S 42/36kA 2 pole 3 pole 4 pole Rated current Code Unit (EA) Code Unit (EA) 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A UCB100R 2PT4S0000C 00015 UCB100R 2PT4S0000C 00016 UCB100R 2PT4S0000C 00020 UCB100R 2PT4S0000C 00025 UCB100R 2PT4S0000C 00030 UCB100R 2PT4S0000C 00032 UCB100R 2PT4S0000C 00040 UCB100R 2PT4S0000C 00050 UCB100R 2PT4S0000C 00060 UCB100R 2PT4S0000C 00063 UCB100R 2PT4S0000C 00075 UCB100R 2PT4S0000C 00080 UCB100R 2PT4S0000C 00100 UCB100S 2PT4S0000C 00015 UCB100S 2PT4S0000C 00016 UCB100S 2PT4S0000C 00020 UCB100S 2PT4S0000C 00025 UCB100S 2PT4S0000C 00030 UCB100S 2PT4S0000C 00032 UCB100S 2PT4S0000C 00040 UCB100S 2PT4S0000C 00050 UCB100S 2PT4S0000C 00060 UCB100S 2PT4S0000C 00063 UCB100S 2PT4S0000C 00075 UCB100S 2PT4S0000C 00080 UCB100S 2PT4S0000C 00100 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 UCB100R 3PT4S0000C 00015 UCB100R 3PT4S0000C 00016 UCB100R 3PT4S0000C 00020 UCB100R 3PT4S0000C 00025 UCB100R 3PT4S0000C 00030 UCB100R 3PT4S0000C 00032 UCB100R 3PT4S0000C 00040 UCB100R 3PT4S0000C 00050 UCB100R 3PT4S0000C 00060 UCB100R 3PT4S0000C 00063 UCB100R 3PT4S0000C 00075 UCB100R 3PT4S0000C 00080 UCB100R 3PT4S0000C 00100 UCB100S 3PT4S0000C 00015 UCB100S 3PT4S0000C 00016 UCB100S 3PT4S0000C 00020 UCB100S 3PT4S0000C 00025 UCB100S 3PT4S0000C 00030 UCB100S 3PT4S0000C 00032 UCB100S 3PT4S0000C 00040 UCB100S 3PT4S0000C 00050 UCB100S 3PT4S0000C 00060 UCB100S 3PT4S0000C 00063 UCB100S 3PT4S0000C 00075 UCB100S 3PT4S0000C 00080 UCB100S 3PT4S0000C 00100 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Rated current Code Unit (EA) Code Unit (EA) 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A UCB100R 2PT5S0000C 00015 UCB100R 2PT5S0000C 00016 UCB100R 2PT5S0000C 00020 UCB100R 2PT5S0000C 00025 UCB100R 2PT5S0000C 00030 UCB100R 2PT5S0000C 00032 UCB100R 2PT5S0000C 00040 UCB100R 2PT5S0000C 00050 UCB100R 2PT5S0000C 00060 UCB100R 2PT5S0000C 00063 UCB100R 2PT5S0000C 00075 UCB100R 2PT5S0000C 00080 UCB100R 2PT5S0000C 00100 UCB100S 2PT5S0000C 00015 UCB100S 2PT5S0000C 00016 UCB100S 2PT5S0000C 00020 UCB100S 2PT5S0000C 00025 UCB100S 2PT5S0000C 00030 UCB100S 2PT5S0000C 00032 UCB100S 2PT5S0000C 00040 UCB100S 2PT5S0000C 00050 UCB100S 2PT5S0000C 00060 UCB100S 2PT5S0000C 00063 UCB100S 2PT5S0000C 00075 UCB100S 2PT5S0000C 00080 UCB100S 2PT5S0000C 00100 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 UCB100R 3PT5S0000C 00015 UCB100R 3PT5S0000C 00016 UCB100R 3PT5S0000C 00020 UCB100R 3PT5S0000C 00025 UCB100R 3PT5S0000C 00030 UCB100R 3PT5S0000C 00032 UCB100R 3PT5S0000C 00040 UCB100R 3PT5S0000C 00050 UCB100R 3PT5S0000C 00060 UCB100R 3PT5S0000C 00063 UCB100R 3PT5S0000C 00075 UCB100R 3PT5S0000C 00080 UCB100R 3PT5S0000C 00100 UCB100S 3PT5S0000C 00015 UCB100S 3PT5S0000C 00016 UCB100S 3PT5S0000C 00020 UCB100S 3PT5S0000C 00025 UCB100S 3PT5S0000C 00030 UCB100S 3PT5S0000C 00032 UCB100S 3PT5S0000C 00040 UCB100S 3PT5S0000C 00050 UCB100S 3PT5S0000C 00060 UCB100S 3PT5S0000C 00063 UCB100S 3PT5S0000C 00075 UCB100S 3PT5S0000C 00080 UCB100S 3PT5S0000C 00100 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Code UCB100R 4PT4S0000C 00015 UCB100R 4PT4S0000C 00016 UCB100R 4PT4S0000C 00020 UCB100R 4PT4S0000C 00025 UCB100R 4PT4S0000C 00030 UCB100R 4PT4S0000C 00032 UCB100R 4PT4S0000C 00040 UCB100R 4PT4S0000C 00050 UCB100R 4PT4S0000C 00060 UCB100R 4PT4S0000C 00063 UCB100R 4PT4S0000C 00075 UCB100R 4PT4S0000C 00080 UCB100R 4PT4S0000C 00100 UCB100S 4PT4S0000C 00015 UCB100S 4PT4S0000C 00016 UCB100S 4PT4S0000C 00020 UCB100S 4PT4S0000C 00025 UCB100S 4PT4S0000C 00030 UCB100S 4PT4S0000C 00032 UCB100S 4PT4S0000C 00040 UCB100S 4PT4S0000C 00050 UCB100S 4PT4S0000C 00060 UCB100S 4PT4S0000C 00063 UCB100S 4PT4S0000C 00075 UCB100S 4PT4S0000C 00080 UCB100S 4PT4S0000C 00100 Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UCB100R 30/25kA UCB100S 42/36kA 60 2 pole 3 pole 4 pole Code UCB100R 4PT5S0000C 00015 UCB100R 4PT5S0000C 00016 UCB100R 4PT5S0000C 00020 UCB100R 4PT5S0000C 00025 UCB100R 4PT5S0000C 00030 UCB100R 4PT5S0000C 00032 UCB100R 4PT5S0000C 00040 UCB100R 4PT5S0000C 00050 UCB100R 4PT5S0000C 00060 UCB100R 4PT5S0000C 00063 UCB100R 4PT5S0000C 00075 UCB100R 4PT5S0000C 00080 UCB100R 4PT5S0000C 00100 UCB100S 4PT5S0000C 00015 UCB100S 4PT5S0000C 00016 UCB100S 4PT5S0000C 00020 UCB100S 4PT5S0000C 00025 UCB100S 4PT5S0000C 00030 UCB100S 4PT5S0000C 00032 UCB100S 4PT5S0000C 00040 UCB100S 4PT5S0000C 00050 UCB100S 4PT5S0000C 00060 UCB100S 4PT5S0000C 00063 UCB100S 4PT5S0000C 00075 UCB100S 4PT5S0000C 00080 UCB100S 4PT5S0000C 00100 Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 MCCB �Adjustable thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UCB100R 30/25kA UCB100S 42/36kA 2 pole 3 pole 4 pole Rated current Code Unit (EA) Code Unit (EA) 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A UCB100R 2PT4S0000C 00015F UCB100R 2PT4S0000C 00016F UCB100R 2PT4S0000C 00020F UCB100R 2PT4S0000C 00025F UCB100R 2PT4S0000C 00030F UCB100R 2PT4S0000C 00032F UCB100R 2PT4S0000C 00040F UCB100R 2PT4S0000C 00050F UCB100R 2PT4S0000C 00060F UCB100R 2PT4S0000C 00063F UCB100R 2PT4S0000C 00075F UCB100R 2PT4S0000C 00080F UCB100R 2PT4S0000C 00100F UCB100S 2PT4S0000C 00015F UCB100S 2PT4S0000C 00016F UCB100S 2PT4S0000C 00020F UCB100S 2PT4S0000C 00025F UCB100S 2PT4S0000C 00030F UCB100S 2PT4S0000C 00032F UCB100S 2PT4S0000C 00040F UCB100S 2PT4S0000C 00050F UCB100S 2PT4S0000C 00060F UCB100S 2PT4S0000C 00063F UCB100S 2PT4S0000C 00075F UCB100S 2PT4S0000C 00080F UCB100S 2PT4S0000C 00100F 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 UCB100R 3PT4S0000C 00015F UCB100R 3PT4S0000C 00016F UCB100R 3PT4S0000C 00020F UCB100R 3PT4S0000C 00025F UCB100R 3PT4S0000C 00030F UCB100R 3PT4S0000C 00032F UCB100R 3PT4S0000C 00040F UCB100R 3PT4S0000C 00050F UCB100R 3PT4S0000C 00060F UCB100R 3PT4S0000C 00063F UCB100R 3PT4S0000C 00075F UCB100R 3PT4S0000C 00080F UCB100R 3PT4S0000C 00100F UCB100S 3PT4S0000C 00015F UCB100S 3PT4S0000C 00016F UCB100S 3PT4S0000C 00020F UCB100S 3PT4S0000C 00025F UCB100S 3PT4S0000C 00030F UCB100S 3PT4S0000C 00032F UCB100S 3PT4S0000C 00040F UCB100S 3PT4S0000C 00050F UCB100S 3PT4S0000C 00060F UCB100S 3PT4S0000C 00063F UCB100S 3PT4S0000C 00075F UCB100S 3PT4S0000C 00080F UCB100S 3PT4S0000C 00100F 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Rated current Code Unit (EA) Code Unit (EA) 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A UCB100R 2PT5S0000C 00015F UCB100R 2PT5S0000C 00016F UCB100R 2PT5S0000C 00020F UCB100R 2PT5S0000C 00025F UCB100R 2PT5S0000C 00030F UCB100R 2PT5S0000C 00032F UCB100R 2PT5S0000C 00040F UCB100R 2PT5S0000C 00050F UCB100R 2PT5S0000C 00060F UCB100R 2PT5S0000C 00063F UCB100R 2PT5S0000C 00075F UCB100R 2PT5S0000C 00080F UCB100R 2PT5S0000C 00100F UCB100S 2PT5S0000C 00015F UCB100S 2PT5S0000C 00016F UCB100S 2PT5S0000C 00020F UCB100S 2PT5S0000C 00025F UCB100S 2PT5S0000C 00030F UCB100S 2PT5S0000C 00032F UCB100S 2PT5S0000C 00040F UCB100S 2PT5S0000C 00050F UCB100S 2PT5S0000C 00060F UCB100S 2PT5S0000C 00063F UCB100S 2PT5S0000C 00075F UCB100S 2PT5S0000C 00080F UCB100S 2PT5S0000C 00100F 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 UCB100R 3PT5S0000C 00015F UCB100R 3PT5S0000C 00016F UCB100R 3PT5S0000C 00020F UCB100R 3PT5S0000C 00025F UCB100R 3PT5S0000C 00030F UCB100R 3PT5S0000C 00032F UCB100R 3PT5S0000C 00040F UCB100R 3PT5S0000C 00050F UCB100R 3PT5S0000C 00060F UCB100R 3PT5S0000C 00063F UCB100R 3PT5S0000C 00075F UCB100R 3PT5S0000C 00080F UCB100R 3PT5S0000C 00100F UCB100S 3PT5S0000C 00015F UCB100S 3PT5S0000C 00016F UCB100S 3PT5S0000C 00020F UCB100S 3PT5S0000C 00025F UCB100S 3PT5S0000C 00030F UCB100S 3PT5S0000C 00032F UCB100S 3PT5S0000C 00040F UCB100S 3PT5S0000C 00050F UCB100S 3PT5S0000C 00060F UCB100S 3PT5S0000C 00063F UCB100S 3PT5S0000C 00075F UCB100S 3PT5S0000C 00080F UCB100S 3PT5S0000C 00100F 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Code UCB100R 4PT4S0000C 00015F UCB100R 4PT4S0000C 00016F UCB100R 4PT4S0000C 00020F UCB100R 4PT4S0000C 00025F UCB100R 4PT4S0000C 00030F UCB100R 4PT4S0000C 00032F UCB100R 4PT4S0000C 00040F UCB100R 4PT4S0000C 00050F UCB100R 4PT4S0000C 00060F UCB100R 4PT4S0000C 00063F UCB100R 4PT4S0000C 00075F UCB100R 4PT4S0000C 00080F UCB100R 4PT4S0000C 00100F UCB100S 4PT4S0000C 00015F UCB100S 4PT4S0000C 00016F UCB100S 4PT4S0000C 00020F UCB100S 4PT4S0000C 00025F UCB100S 4PT4S0000C 00030F UCB100S 4PT4S0000C 00032F UCB100S 4PT4S0000C 00040F UCB100S 4PT4S0000C 00050F UCB100S 4PT4S0000C 00060F UCB100S 4PT4S0000C 00063F UCB100S 4PT4S0000C 00075F UCB100S 4PT4S0000C 00080F UCB100S 4PT4S0000C 00100F Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UCB100R 30/25kA UCB100S 42/36kA 2 pole 3 pole 4 pole Code UCB100R 4PT5S0000C 00015F UCB100R 4PT5S0000C 00016F UCB100R 4PT5S0000C 00020F UCB100R 4PT5S0000C 00025F UCB100R 4PT5S0000C 00030F UCB100R 4PT5S0000C 00032F UCB100R 4PT5S0000C 00040F UCB100R 4PT5S0000C 00050F UCB100R 4PT5S0000C 00060F UCB100R 4PT5S0000C 00063F UCB100R 4PT5S0000C 00075F UCB100R 4PT5S0000C 00080F UCB100R 4PT5S0000C 00100F UCB100S 4PT5S0000C 00015F UCB100S 4PT5S0000C 00016F UCB100S 4PT5S0000C 00020F UCB100S 4PT5S0000C 00025F UCB100S 4PT5S0000C 00030F UCB100S 4PT5S0000C 00032F UCB100S 4PT5S0000C 00040F UCB100S 4PT5S0000C 00050F UCB100S 4PT5S0000C 00060F UCB100S 4PT5S0000C 00063F UCB100S 4PT5S0000C 00075F UCB100S 4PT5S0000C 00080F UCB100S 4PT5S0000C 00100F Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 Molded Case Circuit Breaker_ 61 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UCB type / 125AF | �UCB100H 42kA �UCB100L 50kA UCB100H UCB100L �2, 3, 4 Number of poles (P) Degree of protection (with terminal cover) IP20 Utilization category A Suitability of isolation ○ Protection overload, inst., short-circuit Rated current (A) 15,16,20,25,30,32,40,50,60,63,75,80,100,125 Rated insulation voltage [Ui] (V) Rating AC690 AC660 Rated operational voltage [Ue] (V) DC250 Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit breaking capacity Ultimate [Icu] (kA r.m.s.) IEC 60947-2 K 60947-2 AC600/660V, 50-60Hz 20 25 AC480/500V, 50-60Hz 30 35 AC440/460V, 50-60Hz 42 50 AC380/415V, 50-60Hz 42 50 AC220/240V, 50-60Hz 85 100 DC250V 25 40 DC125V 40 60 Service [Ics] % of [Icu] Trip Thermal mechanism & Protection magnetic characteristics 75 Fixed thermal, Fixed instantaneous Adjustable thermal, Fixed instantaneous ○ INST 15-32A: 15×In, 40-125A: 10×In LTD (0.8-0.9-1)×In INST 15-32A: 15×In, 40-125A: 10×In ○ Direct mounting by screw Mounting Plug-in Terminal connection Durability (times) Both line & load side for Switchboard Line side only ○1) for Distribution board ○1) Screw ○ Mechanical operation b d c 2/3/4P 10,000 a Width 902)/90/120 b Height 155 c Depth 60 d Weight (kg, breaker only) 2/3/4P ○1) 25,000 Electrical operation a Dimensions (mm) 6 84.5 0.9/1.0/1.3 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 2) �2P breaker has same dimension as 3P breaker, but the middle pole is removed. 62 MCCB ■ Accessories �Signal 1ab, Right-hand-side 2ab, Right-hand-side Auxiliary switch Trip alarm switch Shunt trip 1) Under voltage trip 2) AUX 12FG R1 AUX 12FG R2 1ab, Right-hand-side 1ab, Left-hand-side ALT 12FG R1 ALT 12FG L1 DC24V DC100-110V AC100-120V AC200-230V AC380-415V SHT 12FG A SHT 12FG C SHT 12FG F SHT 12FG H SHT 12FG B SHT 12FG D DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V UVT 12FG J UVT 12FG L UVT 12FG N UVT 12FG P UVT 12FG Q UVT 12FG R AC440-480V ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Operating Upper Right Left S type TFG 10UFS U4 TFG 10UFS R4 TFG 10UFS L4 L type TFG 10UFL U4 - TFG 10UFL L4 Power supply direction Operating Surface handle1) Extended TFH 10UFS S type TFH 10UFL L type Motor operator 2) DC24V AC/DC110V AC/DC220V MOT 10F DC24 MOT 10F ADC110 MOT 10F ADC220 2 pole 3 pole 4 pole MIF 10UF 3 MIF 10UF 3 MIF 10UF 4 Mechanical interlock ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting For both line & load side For line side only TDM 10BP TDF 10B Plug-in1) Connection 2C contact CBM 10AB 2 - 2) CBM 10AB 3 - CBM BARR - Structure Mounting base block 3C contact Conn. block barrier ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal Cage terminal block Terminal cover1) Interpole barrier2) 2EA/SET 3EA/SET 4EA/SET CTB 10B 3S CTB 10B 4S 2 pole 3 pole 4 pole TCF 10FP 3 TCF 10FP 3 TCF 10FP 4 TQQ 12FG ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 2EA, 3 pole 4EA, 4 pole 6EA Molded Case Circuit Breaker_ 63 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UCB100H 42kA UCB100L 50kA Rated current 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 125A 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 125A 2 pole Code UCB100H 2PT4S0000C 00015 UCB100H 2PT4S0000C 00016 UCB100H 2PT4S0000C 00020 UCB100H 2PT4S0000C 00025 UCB100H 2PT4S0000C 00030 UCB100H 2PT4S0000C 00032 UCB100H 2PT4S0000C 00040 UCB100H 2PT4S0000C 00050 UCB100H 2PT4S0000C 00060 UCB100H 2PT4S0000C 00063 UCB100H 2PT4S0000C 00075 UCB100H 2PT4S0000C 00080 UCB100H 2PT4S0000C 00100 UCB100H 2PT4S0000C 00125 UCB100L 2PT4S0000C 00015 UCB100L 2PT4S0000C 00016 UCB100L 2PT4S0000C 00020 UCB100L 2PT4S0000C 00025 UCB100L 2PT4S0000C 00030 UCB100L 2PT4S0000C 00032 UCB100L 2PT4S0000C 00040 UCB100L 2PT4S0000C 00050 UCB100L 2PT4S0000C 00060 UCB100L 2PT4S0000C 00063 UCB100L 2PT4S0000C 00075 UCB100L 2PT4S0000C 00080 UCB100L 2PT4S0000C 00100 UCB100L 2PT4S0000C 00125 Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 3 pole Code UCB100H 3PT4S0000C 00015 UCB100H 3PT4S0000C 00016 UCB100H 3PT4S0000C 00020 UCB100H 3PT4S0000C 00025 UCB100H 3PT4S0000C 00030 UCB100H 3PT4S0000C 00032 UCB100H 3PT4S0000C 00040 UCB100H 3PT4S0000C 00050 UCB100H 3PT4S0000C 00060 UCB100H 3PT4S0000C 00063 UCB100H 3PT4S0000C 00075 UCB100H 3PT4S0000C 00080 UCB100H 3PT4S0000C 00100 UCB100H 3PT4S0000C 00125 UCB100L 3PT4S0000C 00015 UCB100L 3PT4S0000C 00016 UCB100L 3PT4S0000C 00020 UCB100L 3PT4S0000C 00025 UCB100L 3PT4S0000C 00030 UCB100L 3PT4S0000C 00032 UCB100L 3PT4S0000C 00040 UCB100L 3PT4S0000C 00050 UCB100L 3PT4S0000C 00060 UCB100L 3PT4S0000C 00063 UCB100L 3PT4S0000C 00075 UCB100L 3PT4S0000C 00080 UCB100L 3PT4S0000C 00100 UCB100L 3PT4S0000C 00125 Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 4 pole Code UCB100H 4PT4S0000C 00015 UCB100H 4PT4S0000C 00016 UCB100H 4PT4S0000C 00020 UCB100H 4PT4S0000C 00025 UCB100H 4PT4S0000C 00030 UCB100H 4PT4S0000C 00032 UCB100H 4PT4S0000C 00040 UCB100H 4PT4S0000C 00050 UCB100H 4PT4S0000C 00060 UCB100H 4PT4S0000C 00063 UCB100H 4PT4S0000C 00075 UCB100H 4PT4S0000C 00080 UCB100H 4PT4S0000C 00100 UCB100H 4PT4S0000C 00125 UCB100L 4PT4S0000C 00015 UCB100L 4PT4S0000C 00016 UCB100L 4PT4S0000C 00020 UCB100L 4PT4S0000C 00025 UCB100L 4PT4S0000C 00030 UCB100L 4PT4S0000C 00032 UCB100L 4PT4S0000C 00040 UCB100L 4PT4S0000C 00050 UCB100L 4PT4S0000C 00060 UCB100L 4PT4S0000C 00063 UCB100L 4PT4S0000C 00075 UCB100L 4PT4S0000C 00080 UCB100L 4PT4S0000C 00100 UCB100L 4PT4S0000C 00125 Unit (EA) 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UCB100H 42kA UCB100L 50kA 64 Rated current 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 125A 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 125A 2 pole Code UCB100H 2PT5S0000C 00015 UCB100H 2PT5S0000C 00016 UCB100H 2PT5S0000C 00020 UCB100H 2PT5S0000C 00025 UCB100H 2PT5S0000C 00030 UCB100H 2PT5S0000C 00032 UCB100H 2PT5S0000C 00040 UCB100H 2PT5S0000C 00050 UCB100H 2PT5S0000C 00060 UCB100H 2PT5S0000C 00063 UCB100H 2PT5S0000C 00075 UCB100H 2PT5S0000C 00080 UCB100H 2PT5S0000C 00100 UCB100H 2PT5S0000C 00125 UCB100L 2PT5S0000C 00015 UCB100L 2PT5S0000C 00016 UCB100L 2PT5S0000C 00020 UCB100L 2PT5S0000C 00025 UCB100L 2PT5S0000C 00030 UCB100L 2PT5S0000C 00032 UCB100L 2PT5S0000C 00040 UCB100L 2PT5S0000C 00050 UCB100L 2PT5S0000C 00060 UCB100L 2PT5S0000C 00063 UCB100L 2PT5S0000C 00075 UCB100L 2PT5S0000C 00080 UCB100L 2PT5S0000C 00100 UCB100L 2PT5S0000C 00125 Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 3 pole Code UCB100H 3PT5S0000C 00015 UCB100H 3PT5S0000C 00016 UCB100H 3PT5S0000C 00020 UCB100H 3PT5S0000C 00025 UCB100H 3PT5S0000C 00030 UCB100H 3PT5S0000C 00032 UCB100H 3PT5S0000C 00040 UCB100H 3PT5S0000C 00050 UCB100H 3PT5S0000C 00060 UCB100H 3PT5S0000C 00063 UCB100H 3PT5S0000C 00075 UCB100H 3PT5S0000C 00080 UCB100H 3PT5S0000C 00100 UCB100H 3PT5S0000C 00125 UCB100L 3PT5S0000C 00015 UCB100L 3PT5S0000C 00016 UCB100L 3PT5S0000C 00020 UCB100L 3PT5S0000C 00025 UCB100L 3PT5S0000C 00030 UCB100L 3PT5S0000C 00032 UCB100L 3PT5S0000C 00040 UCB100L 3PT5S0000C 00050 UCB100L 3PT5S0000C 00060 UCB100L 3PT5S0000C 00063 UCB100L 3PT5S0000C 00075 UCB100L 3PT5S0000C 00080 UCB100L 3PT5S0000C 00100 UCB100L 3PT5S0000C 00125 Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 4 pole Code UCB100H 4PT5S0000C 00015 UCB100H 4PT5S0000C 00016 UCB100H 4PT5S0000C 00020 UCB100H 4PT5S0000C 00025 UCB100H 4PT5S0000C 00030 UCB100H 4PT5S0000C 00032 UCB100H 4PT5S0000C 00040 UCB100H 4PT5S0000C 00050 UCB100H 4PT5S0000C 00060 UCB100H 4PT5S0000C 00063 UCB100H 4PT5S0000C 00075 UCB100H 4PT5S0000C 00080 UCB100H 4PT5S0000C 00100 UCB100H 4PT5S0000C 00125 UCB100L 4PT5S0000C 00015 UCB100L 4PT5S0000C 00016 UCB100L 4PT5S0000C 00020 UCB100L 4PT5S0000C 00025 UCB100L 4PT5S0000C 00030 UCB100L 4PT5S0000C 00032 UCB100L 4PT5S0000C 00040 UCB100L 4PT5S0000C 00050 UCB100L 4PT5S0000C 00060 UCB100L 4PT5S0000C 00063 UCB100L 4PT5S0000C 00075 UCB100L 4PT5S0000C 00080 UCB100L 4PT5S0000C 00100 UCB100L 4PT5S0000C 00125 Unit (EA) 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 MCCB �Adjustable thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UCB100H 42kA UCB100L 50kA Rated current 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 125A 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 125A 2 pole Code UCB100H 2PT4S0000C 00015F UCB100H 2PT4S0000C 00016F UCB100H 2PT4S0000C 00020F UCB100H 2PT4S0000C 00025F UCB100H 2PT4S0000C 00030F UCB100H 2PT4S0000C 00032F UCB100H 2PT4S0000C 00040F UCB100H 2PT4S0000C 00050F UCB100H 2PT4S0000C 00060F UCB100H 2PT4S0000C 00063F UCB100H 2PT4S0000C 00075F UCB100H 2PT4S0000C 00080F UCB100H 2PT4S0000C 00100F UCB100H 2PT4S0000C 00125F UCB100L 2PT4S0000C 00015F UCB100L 2PT4S0000C 00016F UCB100L 2PT4S0000C 00020F UCB100L 2PT4S0000C 00025F UCB100L 2PT4S0000C 00030F UCB100L 2PT4S0000C 00032F UCB100L 2PT4S0000C 00040F UCB100L 2PT4S0000C 00050F UCB100L 2PT4S0000C 00060F UCB100L 2PT4S0000C 00063F UCB100L 2PT4S0000C 00075F UCB100L 2PT4S0000C 00080F UCB100L 2PT4S0000C 00100F UCB100L 2PT4S0000C 00125F Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 3 pole Code UCB100H 3PT4S0000C 00015F UCB100H 3PT4S0000C 00016F UCB100H 3PT4S0000C 00020F UCB100H 3PT4S0000C 00025F UCB100H 3PT4S0000C 00030F UCB100H 3PT4S0000C 00032F UCB100H 3PT4S0000C 00040F UCB100H 3PT4S0000C 00050F UCB100H 3PT4S0000C 00060F UCB100H 3PT4S0000C 00063F UCB100H 3PT4S0000C 00075F UCB100H 3PT4S0000C 00080F UCB100H 3PT4S0000C 00100F UCB100H 3PT4S0000C 00125F UCB100L 3PT4S0000C 00015F UCB100L 3PT4S0000C 00016F UCB100L 3PT4S0000C 00020F UCB100L 3PT4S0000C 00025F UCB100L 3PT4S0000C 00030F UCB100L 3PT4S0000C 00032F UCB100L 3PT4S0000C 00040F UCB100L 3PT4S0000C 00050F UCB100L 3PT4S0000C 00060F UCB100L 3PT4S0000C 00063F UCB100L 3PT4S0000C 00075F UCB100L 3PT4S0000C 00080F UCB100L 3PT4S0000C 00100F UCB100L 3PT4S0000C 00125F Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 4 pole Code UCB100H 4PT4S0000C 00015F UCB100H 4PT4S0000C 00016F UCB100H 4PT4S0000C 00020F UCB100H 4PT4S0000C 00025F UCB100H 4PT4S0000C 00030F UCB100H 4PT4S0000C 00032F UCB100H 4PT4S0000C 00040F UCB100H 4PT4S0000C 00050F UCB100H 4PT4S0000C 00060F UCB100H 4PT4S0000C 00063F UCB100H 4PT4S0000C 00075F UCB100H 4PT4S0000C 00080F UCB100H 4PT4S0000C 00100F UCB100H 4PT4S0000C 00125F UCB100L 4PT4S0000C 00015F UCB100L 4PT4S0000C 00016F UCB100L 4PT4S0000C 00020F UCB100L 4PT4S0000C 00025F UCB100L 4PT4S0000C 00030F UCB100L 4PT4S0000C 00032F UCB100L 4PT4S0000C 00040F UCB100L 4PT4S0000C 00050F UCB100L 4PT4S0000C 00060F UCB100L 4PT4S0000C 00063F UCB100L 4PT4S0000C 00075F UCB100L 4PT4S0000C 00080F UCB100L 4PT4S0000C 00100F UCB100L 4PT4S0000C 00125F Unit (EA) 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UCB100H 42kA UCB100L 50kA Rated current 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 125A 15A 16A 20A 25A 30A 32A 40A 50A 60A 63A 75A 80A 100A 125A 2 pole Code UCB100H 2PT5S0000C 00015F UCB100H 2PT5S0000C 00016F UCB100H 2PT5S0000C 00020F UCB100H 2PT5S0000C 00025F UCB100H 2PT5S0000C 00030F UCB100H 2PT5S0000C 00032F UCB100H 2PT5S0000C 00040F UCB100H 2PT5S0000C 00050F UCB100H 2PT5S0000C 00060F UCB100H 2PT5S0000C 00063F UCB100H 2PT5S0000C 00075F UCB100H 2PT5S0000C 00080F UCB100H 2PT5S0000C 00100F UCB100H 2PT5S0000C 00125F UCB100L 2PT5S0000C 00015F UCB100L 2PT5S0000C 00016F UCB100L 2PT5S0000C 00020F UCB100L 2PT5S0000C 00025F UCB100L 2PT5S0000C 00030F UCB100L 2PT5S0000C 00032F UCB100L 2PT5S0000C 00040F UCB100L 2PT5S0000C 00050F UCB100L 2PT5S0000C 00060F UCB100L 2PT5S0000C 00063F UCB100L 2PT5S0000C 00075F UCB100L 2PT5S0000C 00080F UCB100L 2PT5S0000C 00100F UCB100L 2PT5S0000C 00125F Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 3 pole Code UCB100H 3PT5S0000C 00015F UCB100H 3PT5S0000C 00016F UCB100H 3PT5S0000C 00020F UCB100H 3PT5S0000C 00025F UCB100H 3PT5S0000C 00030F UCB100H 3PT5S0000C 00032F UCB100H 3PT5S0000C 00040F UCB100H 3PT5S0000C 00050F UCB100H 3PT5S0000C 00060F UCB100H 3PT5S0000C 00063F UCB100H 3PT5S0000C 00075F UCB100H 3PT5S0000C 00080F UCB100H 3PT5S0000C 00100F UCB100H 3PT5S0000C 00125F UCB100L 3PT5S0000C 00015F UCB100L 3PT5S0000C 00016F UCB100L 3PT5S0000C 00020F UCB100L 3PT5S0000C 00025F UCB100L 3PT5S0000C 00030F UCB100L 3PT5S0000C 00032F UCB100L 3PT5S0000C 00040F UCB100L 3PT5S0000C 00050F UCB100L 3PT5S0000C 00060F UCB100L 3PT5S0000C 00063F UCB100L 3PT5S0000C 00075F UCB100L 3PT5S0000C 00080F UCB100L 3PT5S0000C 00100F UCB100L 3PT5S0000C 00125F Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 4 pole Code UCB100H 4PT5S0000C 00015F UCB100H 4PT5S0000C 00016F UCB100H 4PT5S0000C 00020F UCB100H 4PT5S0000C 00025F UCB100H 4PT5S0000C 00030F UCB100H 4PT5S0000C 00032F UCB100H 4PT5S0000C 00040F UCB100H 4PT5S0000C 00050F UCB100H 4PT5S0000C 00060F UCB100H 4PT5S0000C 00063F UCB100H 4PT5S0000C 00075F UCB100H 4PT5S0000C 00080F UCB100H 4PT5S0000C 00100F UCB100H 4PT5S0000C 00125F UCB100L 4PT5S0000C 00015F UCB100L 4PT5S0000C 00016F UCB100L 4PT5S0000C 00020F UCB100L 4PT5S0000C 00025F UCB100L 4PT5S0000C 00030F UCB100L 4PT5S0000C 00032F UCB100L 4PT5S0000C 00040F UCB100L 4PT5S0000C 00050F UCB100L 4PT5S0000C 00060F UCB100L 4PT5S0000C 00063F UCB100L 4PT5S0000C 00075F UCB100L 4PT5S0000C 00080F UCB100L 4PT5S0000C 00100F UCB100L 4PT5S0000C 00125F Unit (EA) 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 Molded Case Circuit Breaker_ 65 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UCB type / 160AF | �UCB160H 42kA �UCB160L 50kA UCB160H �2, 3, 4 Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated short-circuit breaking capacity IEC 60947-2 K 60947-2 Rated impulse withstand voltage [Uimp] (kV) AC600/660V, 50-60Hz AC480/500V, 50-60Hz AC440/460V, 50-60Hz Ultimate [Icu] AC380/415V, 50-60Hz (kA r.m.s.) AC220/240V, 50-60Hz DC250V DC125V Service [Ics] % of [Icu] Trip Thermal mechanism & Protection magnetic characteristics Fixed thermal, Fixed instantaneous Adjustable thermal, Fixed instantaneous UCB160L IP20 A ○ overload, inst., short-circuit 100,125,160 AC690 AC660 DC250 6 20 30 42 42 85 25 40 25 35 50 50 100 40 60 50 ○ 10×In (0.8-0.9-1)×In 10×In ○ ○1) ○1) ○1) ○ ○ 25,000 10,000 1052)/105/140 165 60 84.5 1.1/1.3/1.6 INST LTD INST Direct mounting by screw Both line & load side for Mounting Switchboard Line side only Plug-in for Distribution board Screw Terminal connection Bus bar Mechanical operation Durability (times) Electrical operation a Width d a c b Height Dimensions 2/3/4P b (mm) c Depth d Weight (kg, breaker only) 2/3/4P ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 2) �2P breaker has same dimension as 3P breaker, but the middle pole is removed. ■ Accessories �Signal Auxiliary switch Trip alarm switch Shunt trip1) Under voltage trip 2) 1ab, Right-hand-side AUX 12FG R1 1ab, Right-hand-side ALT 12FG R1 DC24V SHT 12FG A DC24V UVT 12FG J 2ab, Right-hand-side AUX 12FG R2 1ab, Left-hand-side ALT 12FG L1 DC100-110V SHT 12FG C DC100-110V UVT 12FG L AC100-120V SHT 12FG F AC100-120V UVT 12FG N ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) 66 AC200-230V SHT 12FG H AC200-230V UVT 12FG P AC380-415V SHT 12FG B AC380-415V UVT 12FG Q AC440-480V SHT 12FG D AC440-480V UVT 12FG R MCCB �Operating Operating handle1) Upper TFG 20UGS U4 TFG 20UGL U4 Power supply direction S type Surface L type S type Extended L type Right TFG 20UGS R4 TFH 20UGS TFH 20UGL AC/DC110V MOT 20G ADC110 3 pole MIF 20UG 3 DC24V MOT 20G DC24 2 pole MIF 20UG 3 Motor operator 2) Mechanical interlock Left TFG 20UGS L4 TFG 20UGL L4 AC/DC220V MOT 20G ADC220 4 pole MIF 20UG 4 ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting Plug-in1) Structure Mounting base Connection 2C contact 5C contact block2) For both line & load side TDM 20CF3) CBM 20C 2 CBM 20C 5 For line side only TDM 20CF - ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. 3) 2EA are required for both line & load side plug-in type 3P breaker. �Terminal 2 pole (4EA/SET) TBB 20C 2 3EA/SET CTB 20C 3S 2 pole TCF 20GP 3 Terminal bus bar Cage terminal block Terminal cover 1) Interpole barrier 2) 2EA/SET 3 pole (6EA/SET) 4 pole (8EA/SET) TBB 20C 3 TBB 20C 4 4EA/SET CTB 20C 4S 3 pole 4 pole TCF 20GP 3 TCF 20GP 4 TQQ 12FG ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 4EA, 3 pole 4EA, 4 pole 6EA ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UCB160H 42kA UCB160L 50kA Rated current 2 pole Code 100A 125A 160A 100A 125A 160A UCB160H 2PT4S0000C 00100 UCB160H 2PT4S0000C 00125 UCB160H 2PT4S0000C 00160 UCB160L 2PT4S0000C 00100 UCB160L 2PT4S0000C 00125 UCB160L 2PT4S0000C 00160 Rated current 2 pole Code UCB160H 2PT5S0000C 00100 UCB160H 2PT5S0000C 00125 UCB160H 2PT5S0000C 00160 UCB160L 2PT5S0000C 00100 UCB160L 2PT5S0000C 00125 UCB160L 2PT5S0000C 00160 Unit (EA) 8 8 8 8 8 8 3 pole Code UCB160H 3PT4S0000C 00100 UCB160H 3PT4S0000C 00125 UCB160H 3PT4S0000C 00160 UCB160L 3PT4S0000C 00100 UCB160L 3PT4S0000C 00125 UCB160L 3PT4S0000C 00160 Unit (EA) 8 8 8 8 8 8 4 pole Code UCB160H 4PT4S0000C 00100 UCB160H 4PT4S0000C 00125 UCB160H 4PT4S0000C 00160 UCB160L 4PT4S0000C 00100 UCB160L 4PT4S0000C 00125 UCB160L 4PT4S0000C 00160 Unit (EA) 6 6 6 6 6 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UCB160H 42kA UCB160L 50kA 100A 125A 160A 100A 125A 160A Unit (EA) 8 8 8 8 8 8 3 pole Unit Code (EA) UCB160H 3PT5S0000C 00100 8 UCB160H 3PT5S0000C 00125 8 UCB160H 3PT5S0000C 00160 8 UCB160L 3PT5S0000C 00100 8 UCB160L 3PT5S0000C 00125 8 UCB160L 3PT5S0000C 00160 8 4 pole Code UCB160H 4PT5S0000C 00100 UCB160H 4PT5S0000C 00125 UCB160H 4PT5S0000C 00160 UCB160L 4PT5S0000C 00100 UCB160L 4PT5S0000C 00125 UCB160L 4PT5S0000C 00160 Unit (EA) 6 6 6 6 6 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 �Adjustable thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UCB160H 42kA UCB160L 50kA Rated current 100A 125A 160A 100A 125A 160A 2 pole Unit Code (EA) UCB160H 2PT4S0000C 00100F 8 UCB160H 2PT4S0000C 00125F 8 UCB160H 2PT4S0000C 00160F 8 UCB160L 2PT4S0000C 00100F 8 UCB160L 2PT4S0000C 00125F 8 UCB160L 2PT4S0000C 00160F 8 3 pole Code UCB160H 3PT4S0000C 00100F UCB160H 3PT4S0000C 00125F UCB160H 3PT4S0000C 00160F UCB160L 3PT4S0000C 00100F UCB160L 3PT4S0000C 00125F UCB160L 3PT4S0000C 00160F Unit (EA) 8 8 8 8 8 8 4 pole Unit Specification Category Code (EA) UCB160H 4PT4S0000C 00100F 6 UCB160H 4PT4S0000C 00125F 6 Screw type terminal MCCB UCB160H 4PT4S0000C 00160F 6 connection, /M2 UCB160L 4PT4S0000C 00100F 6 No option, UCB160L 4PT4S0000C 00125F 6 50/60Hz UCB160L 4PT4S0000C 00160F 6 50℃ Model / Breaking capacity at AC380/415V UCB160H 42kA UCB160L 50kA Rated current 100A 125A 160A 100A 125A 160A 2 pole 3 pole 4 pole Unit Unit Unit Specification Category Code Code Code (EA) (EA) (EA) UCB160H 2PT5S0000C 00100F 8 UCB160H 3PT5S0000C 00100F 8 UCB160H 4PT5S0000C 00100F 6 Screw type UCB160H 2PT5S0000C 00125F 8 UCB160H 3PT5S0000C 00125F 8 UCB160H 4PT5S0000C 00125F 6 terminal UCB160H 2PT5S0000C 00160F 8 UCB160H 3PT5S0000C 00160F 8 UCB160H 4PT5S0000C 00160F 6 connection, MCCB /M2 UCB160L 2PT5S0000C 00100F 8 UCB160L 3PT5S0000C 00100F 8 UCB160L 4PT5S0000C 00100F 6 No option, UCB160L 2PT5S0000C 00125F 8 UCB160L 3PT5S0000C 00125F 8 UCB160L 4PT5S0000C 00125F 6 50/60Hz UCB160L 2PT5S0000C 00160F 8 UCB160L 3PT5S0000C 00160F 8 UCB160L 4PT5S0000C 00160F 6 Molded Case Circuit Breaker_ 67 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UCB type / 250AF | �UCB250R 25/18kA �UCB250S 35/25kA �UCB250N 42/36kA UCB250R UCB250S �2, 3, 4 Number of poles (P) Degree of protection (with terminal cover) IP20 Utilization category A Suitability of isolation ○ Protection overload, inst., short-circuit Rated current (A) 125,150,160,175,200,225,250 Rated insulation voltage [Ui] (V) Rating UCB250N AC690 AC660 Rated operational voltage [Ue] (V) DC250 Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit breaking capacity Ultimate [Icu] (kA r.m.s.) IEC 60947-2 K 60947-2 AC600/660V, 50-60Hz 7.5 10 18 AC480/500V, 50-60Hz 10 14 25 AC440/460V, 50-60Hz 18 25 35 AC380/415V, 50-60Hz 25/18 35/25 42/36 AC220/240V, 50-60Hz 35 50 65 DC250V 10 14 18 DC125V 15 20 25 Service [Ics] % of [Icu] Trip mechanism Thermal magnetic & Protection characteristics 50 Fixed thermal, Fixed instantaneous Adjustable thermal, Fixed instantaneous ○ INST 10×In LTD (0.8-0.9-1)×In INST 10×In ○ Direct mounting by screw Mounting Plug-in Terminal connection Durability (times) Both line & load side for Switchboard Line side only ○1) for Distribution board ○1) Screw ○ Bus bar ○ ○1) Mechanical operation 25,000 Electrical operation 10,000 a Dimensions (mm) 6 b a Width 1052)/105/140 b Height 164 c Depth 60 d c 2/3/4P d Weight (kg, breaker only) 2/3/4P 84 1.1/1.2/1.5 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 2) �2P breaker has same dimension as 3P breaker, but the middle pole is removed. 68 MCCB ■ Accessories �Signal 1ab, Left-hand-side Auxiliary switch AUX 20C L1 1ab, Left-hand-side Trip alarm switch Shunt trip ALT 20C L1 1) Under voltage trip 2) DC24V DC100-110V AC100-120V SHT 20C A SHT 20C C SHT 20C F AC200-230V AC380-415V AC440-480V DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V UVT 20C J UVT 20C L UVT 20C N UVT 20C P UVT 20C Q UVT 20C R SHT 20C H ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Operating Upper Right Left S type TFG 20CS U4 TFG 20CS R4 TFG 20CS L4 L type TFG 20CL U4 - TFG 20CL L4 Power supply direction Operating Surface handle1) Extended TFH 20CS S type TFH 20CL L type Motor operator 2) DC24V AC/DC110V AC/DC220V MOT 20C DC24 MOT 20C ADC110 MOT 20C ADC220 2 pole 3 pole 4 pole MIF 20UG 3 MIF 20UG 3 MIF 20UG 4 Mechanical interlock ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting For both line & load side Structure Plug-in1) For line side only 3) TDM 20CF Mounting base TDM 20CF Connection 2C contact CBM 20C 2 - block 2) CBM 20C 5 - 5C contact ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. 3) 2EA are required for both line & load side plug-in type 3P breaker. �Terminal 2 pole (4EA/SET) 3 pole (6EA/SET) 4 pole (8EA/SET) Terminal bus bar TBB 20C 2 Cage terminal block Terminal cover 2EA/SET TBB 20C 4 4EA/SET CTB 20C 3S 1) Interpole barrier 2) TBB 20C 3 3EA/SET CTB 20C 4S 2 pole 3 pole 4 pole TCF 20CP 3 TCF 20CP 3 TCF 20CP 4 TQQ 20C ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 4EA, 3 pole 4EA, 4 pole 6EA Molded Case Circuit Breaker_ 69 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UCB250R 25/18kA UCB250S 35/25kA UCB250N 42/36kA Rated current 2 pole Code Unit (EA) 3 pole Code Unit (EA) 4 pole Code Unit (EA) 125A UCB250R 2PT4S0000C 00125 10 UCB250R 3PT4S0000C 00125 10 UCB250R 4PT4S0000C 00125 8 150A UCB250R 2PT4S0000C 00150 10 UCB250R 3PT4S0000C 00150 10 UCB250R 4PT4S0000C 00150 8 160A UCB250R 2PT4S0000C 00160 10 UCB250R 3PT4S0000C 00160 10 UCB250R 4PT4S0000C 00160 8 175A UCB250R 2PT4S0000C 00175 10 UCB250R 3PT4S0000C 00175 10 UCB250R 4PT4S0000C 00175 8 200A UCB250R 2PT4S0000C 00200 10 UCB250R 3PT4S0000C 00200 10 UCB250R 4PT4S0000C 00200 8 225A UCB250R 2PT4S0000C 00225 10 UCB250R 3PT4S0000C 00225 10 UCB250R 4PT4S0000C 00225 8 250A UCB250R 2PT4S0000C 00250 10 UCB250R 3PT4S0000C 00250 10 UCB250R 4PT4S0000C 00250 8 125A UCB250S 2PT4S0000C 00125 10 UCB250S 3PT4S0000C 00125 10 UCB250S 4PT4S0000C 00125 8 150A UCB250S 2PT4S0000C 00150 10 UCB250S 3PT4S0000C 00150 10 UCB250S 4PT4S0000C 00150 8 160A UCB250S 2PT4S0000C 00160 10 UCB250S 3PT4S0000C 00160 10 UCB250S 4PT4S0000C 00160 8 175A UCB250S 2PT4S0000C 00175 10 UCB250S 3PT4S0000C 00175 10 UCB250S 4PT4S0000C 00175 8 200A UCB250S 2PT4S0000C 00200 10 UCB250S 3PT4S0000C 00200 10 UCB250S 4PT4S0000C 00200 8 225A UCB250S 2PT4S0000C 00225 10 UCB250S 3PT4S0000C 00225 10 UCB250S 4PT4S0000C 00225 8 250A UCB250S 2PT4S0000C 00250 10 UCB250S 3PT4S0000C 00250 10 UCB250S 4PT4S0000C 00250 8 125A UCB250N 2PT4S0000C 00125 10 UCB250N 3PT4S0000C 00125 10 UCB250N 4PT4S0000C 00125 8 150A UCB250N 2PT4S0000C 00150 10 UCB250N 3PT4S0000C 00150 10 UCB250N 4PT4S0000C 00150 8 160A UCB250N 2PT4S0000C 00160 10 UCB250N 3PT4S0000C 00160 10 UCB250N 4PT4S0000C 00160 8 175A UCB250N 2PT4S0000C 00175 10 UCB250N 3PT4S0000C 00175 10 UCB250N 4PT4S0000C 00175 8 200A UCB250N 2PT4S0000C 00200 10 UCB250N 3PT4S0000C 00200 10 UCB250N 4PT4S0000C 00200 8 225A UCB250N 2PT4S0000C 00225 10 UCB250N 3PT4S0000C 00225 10 UCB250N 4PT4S0000C 00225 8 250A UCB250N 2PT4S0000C 00250 10 UCB250N 3PT4S0000C 00250 10 UCB250N 4PT4S0000C 00250 8 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UCB250R 25/18kA UCB250S 35/25kA UCB250N 42/36kA 70 Rated current 2 pole Code Unit (EA) 3 pole Code Unit (EA) 4 pole Code Unit (EA) 125A UCB250R 2PT5S0000C 00125 10 UCB250R 3PT5S0000C 00125 10 UCB250R 4PT5S0000C 00125 8 150A UCB250R 2PT5S0000C 00150 10 UCB250R 3PT5S0000C 00150 10 UCB250R 4PT5S0000C 00150 8 160A UCB250R 2PT5S0000C 00160 10 UCB250R 3PT5S0000C 00160 10 UCB250R 4PT5S0000C 00160 8 175A UCB250R 2PT5S0000C 00175 10 UCB250R 3PT5S0000C 00175 10 UCB250R 4PT5S0000C 00175 8 200A UCB250R 2PT5S0000C 00200 10 UCB250R 3PT5S0000C 00200 10 UCB250R 4PT5S0000C 00200 8 225A UCB250R 2PT5S0000C 00225 10 UCB250R 3PT5S0000C 00225 10 UCB250R 4PT5S0000C 00225 8 250A UCB250R 2PT5S0000C 00250 10 UCB250R 3PT5S0000C 00250 10 UCB250R 4PT5S0000C 00250 8 125A UCB250S 2PT5S0000C 00125 10 UCB250S 3PT5S0000C 00125 10 UCB250S 4PT5S0000C 00125 8 150A UCB250S 2PT5S0000C 00150 10 UCB250S 3PT5S0000C 00150 10 UCB250S 4PT5S0000C 00150 8 160A UCB250S 2PT5S0000C 00160 10 UCB250S 3PT5S0000C 00160 10 UCB250S 4PT5S0000C 00160 8 175A UCB250S 2PT5S0000C 00175 10 UCB250S 3PT5S0000C 00175 10 UCB250S 4PT5S0000C 00175 8 200A UCB250S 2PT5S0000C 00200 10 UCB250S 3PT5S0000C 00200 10 UCB250S 4PT5S0000C 00200 8 225A UCB250S 2PT5S0000C 00225 10 UCB250S 3PT5S0000C 00225 10 UCB250S 4PT5S0000C 00225 8 250A UCB250S 2PT5S0000C 00250 10 UCB250S 3PT5S0000C 00250 10 UCB250S 4PT5S0000C 00250 8 125A UCB250N 2PT5S0000C 00125 10 UCB250N 3PT5S0000C 00125 10 UCB250N 4PT5S0000C 00125 8 150A UCB250N 2PT5S0000C 00150 10 UCB250N 3PT5S0000C 00150 10 UCB250N 4PT5S0000C 00150 8 160A UCB250N 2PT5S0000C 00160 10 UCB250N 3PT5S0000C 00160 10 UCB250N 4PT5S0000C 00160 8 175A UCB250N 2PT5S0000C 00175 10 UCB250N 3PT5S0000C 00175 10 UCB250N 4PT5S0000C 00175 8 200A UCB250N 2PT5S0000C 00200 10 UCB250N 3PT5S0000C 00200 10 UCB250N 4PT5S0000C 00200 8 225A UCB250N 2PT5S0000C 00225 10 UCB250N 3PT5S0000C 00225 10 UCB250N 4PT5S0000C 00225 8 250A UCB250N 2PT5S0000C 00250 10 UCB250N 3PT5S0000C 00250 10 UCB250N 4PT5S0000C 00250 8 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 MCCB �Adjustable thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UCB250R 25/18kA UCB250S 35/25kA UCB250N 42/36kA Rated current 2 pole Code Unit (EA) 3 pole Code Unit (EA) 4 pole Code Unit (EA) 125A UCB250R 2PT4S0000C 00125F 10 UCB250R 3PT4S0000C 00125F 10 UCB250R 4PT4S0000C 00125F 8 150A UCB250R 2PT4S0000C 00150F 10 UCB250R 3PT4S0000C 00150F 10 UCB250R 4PT4S0000C 00150F 8 160A UCB250R 2PT4S0000C 00160F 10 UCB250R 3PT4S0000C 00160F 10 UCB250R 4PT4S0000C 00160F 8 175A UCB250R 2PT4S0000C 00175F 10 UCB250R 3PT4S0000C 00175F 10 UCB250R 4PT4S0000C 00175F 8 200A UCB250R 2PT4S0000C 00200F 10 UCB250R 3PT4S0000C 00200F 10 UCB250R 4PT4S0000C 00200F 8 225A UCB250R 2PT4S0000C 00225F 10 UCB250R 3PT4S0000C 00225F 10 UCB250R 4PT4S0000C 00225F 8 250A UCB250R 2PT4S0000C 00250F 10 UCB250R 3PT4S0000C 00250F 10 UCB250R 4PT4S0000C 00250F 8 125A UCB250S 2PT4S0000C 00125F 10 UCB250S 3PT4S0000C 00125F 10 UCB250S 4PT4S0000C 00125F 8 150A UCB250S 2PT4S0000C 00150F 10 UCB250S 3PT4S0000C 00150F 10 UCB250S 4PT4S0000C 00150F 8 160A UCB250S 2PT4S0000C 00160F 10 UCB250S 3PT4S0000C 00160F 10 UCB250S 4PT4S0000C 00160F 8 175A UCB250S 2PT4S0000C 00175F 10 UCB250S 3PT4S0000C 00175F 10 UCB250S 4PT4S0000C 00175F 8 200A UCB250S 2PT4S0000C 00200F 10 UCB250S 3PT4S0000C 00200F 10 UCB250S 4PT4S0000C 00200F 8 225A UCB250S 2PT4S0000C 00225F 10 UCB250S 3PT4S0000C 00225F 10 UCB250S 4PT4S0000C 00225F 8 250A UCB250S 2PT4S0000C 00250F 10 UCB250S 3PT4S0000C 00250F 10 UCB250S 4PT4S0000C 00250F 8 125A UCB250N 2PT4S0000C 00125F 10 UCB250N 3PT4S0000C 00125F 10 UCB250N 4PT4S0000C 00125F 8 150A UCB250N 2PT4S0000C 00150F 10 UCB250N 3PT4S0000C 00150F 10 UCB250N 4PT4S0000C 00150F 8 160A UCB250N 2PT4S0000C 00160F 10 UCB250N 3PT4S0000C 00160F 10 UCB250N 4PT4S0000C 00160F 8 175A UCB250N 2PT4S0000C 00175F 10 UCB250N 3PT4S0000C 00175F 10 UCB250N 4PT4S0000C 00175F 8 200A UCB250N 2PT4S0000C 00200F 10 UCB250N 3PT4S0000C 00200F 10 UCB250N 4PT4S0000C 00200F 8 225A UCB250N 2PT4S0000C 00225F 10 UCB250N 3PT4S0000C 00225F 10 UCB250N 4PT4S0000C 00225F 8 250A UCB250N 2PT4S0000C 00250F 10 UCB250N 3PT4S0000C 00250F 10 UCB250N 4PT4S0000C 00250F 8 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UCB250R 25/18kA UCB250S 35/25kA UCB250N 42/36kA Rated current 2 pole Code 125A UCB250R 2PT5S0000C 00125F 10 UCB250R 3PT5S0000C 00125F 10 UCB250R 4PT5S0000C 00125F 8 150A UCB250R 2PT5S0000C 00150F 10 UCB250R 3PT5S0000C 00150F 10 UCB250R 4PT5S0000C 00150F 8 160A UCB250R 2PT5S0000C 00160F 10 UCB250R 3PT5S0000C 00160F 10 UCB250R 4PT5S0000C 00160F 8 175A UCB250R 2PT5S0000C 00175F 10 UCB250R 3PT5S0000C 00175F 10 UCB250R 4PT5S0000C 00175F 8 200A UCB250R 2PT5S0000C 00200F 10 UCB250R 3PT5S0000C 00200F 10 UCB250R 4PT5S0000C 00200F 8 225A UCB250R 2PT5S0000C 00225F 10 UCB250R 3PT5S0000C 00225F 10 UCB250R 4PT5S0000C 00225F 8 250A UCB250R 2PT5S0000C 00250F 10 UCB250R 3PT5S0000C 00250F 10 UCB250R 4PT5S0000C 00250F 8 125A UCB250S 2PT5S0000C 00125F 10 UCB250S 3PT5S0000C 00125F 10 UCB250S 4PT5S0000C 00125F 8 150A UCB250S 2PT5S0000C 00150F 10 UCB250S 3PT5S0000C 00150F 10 UCB250S 4PT5S0000C 00150F 8 160A UCB250S 2PT5S0000C 00160F 10 UCB250S 3PT5S0000C 00160F 10 UCB250S 4PT5S0000C 00160F 8 175A UCB250S 2PT5S0000C 00175F 10 UCB250S 3PT5S0000C 00175F 10 UCB250S 4PT5S0000C 00175F 8 200A UCB250S 2PT5S0000C 00200F 10 UCB250S 3PT5S0000C 00200F 10 UCB250S 4PT5S0000C 00200F 8 225A UCB250S 2PT5S0000C 00225F 10 UCB250S 3PT5S0000C 00225F 10 UCB250S 4PT5S0000C 00225F 8 250A UCB250S 2PT5S0000C 00250F 10 UCB250S 3PT5S0000C 00250F 10 UCB250S 4PT5S0000C 00250F 8 125A UCB250N 2PT5S0000C 00125F 10 UCB250N 3PT5S0000C 00125F 10 UCB250N 4PT5S0000C 00125F 8 150A UCB250N 2PT5S0000C 00150F 10 UCB250N 3PT5S0000C 00150F 10 UCB250N 4PT5S0000C 00150F 8 160A UCB250N 2PT5S0000C 00160F 10 UCB250N 3PT5S0000C 00160F 10 UCB250N 4PT5S0000C 00160F 8 175A UCB250N 2PT5S0000C 00175F 10 UCB250N 3PT5S0000C 00175F 10 UCB250N 4PT5S0000C 00175F 8 200A UCB250N 2PT5S0000C 00200F 10 UCB250N 3PT5S0000C 00200F 10 UCB250N 4PT5S0000C 00200F 8 225A UCB250N 2PT5S0000C 00225F 10 UCB250N 3PT5S0000C 00225F 10 UCB250N 4PT5S0000C 00225F 8 250A UCB250N 2PT5S0000C 00250F 10 UCB250N 3PT5S0000C 00250F 10 UCB250N 4PT5S0000C 00250F 8 Unit (EA) 3 pole Code Unit (EA) 4 pole Code Unit (EA) Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 Molded Case Circuit Breaker_ 71 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UCB type / 250AF | �UCB250H 42kA �UCB250L 50kA UCB250H UCB250L �2, 3, 4 Number of poles (P) Degree of protection (with terminal cover) IP20 Utilization category A Suitability of isolation ○ Protection overload, inst., short-circuit Rated current (A) 125,150,160,175,200,225,250 Rated insulation voltage [Ui] (V) Rating AC690 AC660 Rated operational voltage [Ue] (V) DC250 Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit breaking capacity Ultimate [Icu] (kA r.m.s.) IEC 60947-2 K 60947-2 AC600/660V, 50-60Hz 20 25 AC480/500V, 50-60Hz 30 35 AC440/460V, 50-60Hz 42 50 AC380/415V, 50-60Hz 42 50 AC220/240V, 50-60Hz 85 100 DC250V 25 40 DC125V 40 60 Service [Ics] % of [Icu] Trip mechanism Thermal & Protection magnetic characteristics 50 ○ Fixed thermal, Fixed instantaneous INST 10×In Adjustable thermal, LTD (0.8-0.9-1)×In Fixed instantaneous INST 10×In ○ Direct mounting by screw Mounting Plug-in Terminal connection Durability (times) ○1) Both line & load side for Switchboard Line side only ○1) for Distribution board ○1) Screw ○ Bus bar ○ Mechanical operation 25,000 Electrical operation 10,000 a Dimensions (mm) 6 b a Width 1052)/105/140 b Height 165 c Depth d c 2/3/4P d Weight (kg, breaker only) 2/3/4P 60 84.5 1.1/1.3/1.6 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 2) �2P breaker has same dimension as 3P breaker, but the middle pole is removed. 72 MCCB ■ Accessories �Signal 1ab, Right-hand-side 2ab, Right-hand-side Auxiliary switch Trip alarm switch Shunt trip 1) Under voltage trip 2) AUX 12FG R1 AUX 12FG R2 1ab, Right-hand-side 1ab, Left-hand-side ALT 12FG R1 ALT 12FG L1 DC24V DC100-110V AC100-120V AC200-230V AC380-415V SHT 12FG A SHT 12FG C SHT 12FG F SHT 12FG H SHT 12FG B SHT 12FG D DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V UVT 12FG J UVT 12FG L UVT 12FG N UVT 12FG P UVT 12FG Q UVT 12FG R AC440-480V ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Operating Upper Right Left S type TFG 20UGS U4 TFG 20UGS R4 TFG 20UGS L4 L type TFG 20UGL U4 - TFG 20UGL L4 Power supply direction Operating Surface handle1) Extended TFH 20UGS S type TFH 20UGL L type Motor operator 2) DC24V AC/DC110V AC/DC220V MOT 20G DC24 MOT 20G ADC110 MOT 20G ADC220 2 pole 3 pole 4 pole MIF 20UG 3 MIF 20UG 3 MIF 20UG 4 Mechanical interlock ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting For both line & load side Structure Plug-in1) For line side only 3) TDM 20CF Mounting base TDM 20CF Connection 2C contact CBM 20C 2 - block 2) CBM 20C 5 - 5C contact ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. 3) 2EA are required for both line & load side plug-in type 3P breaker. �Terminal 2 pole (4EA/SET) 3 pole (6EA/SET) 4 pole (8EA/SET) Terminal bus bar TBB 20C 2 Cage terminal block Terminal cover 1) Interpole barrier 2) 2EA/SET TBB 20C 3 TBB 20C 4 3EA/SET 4EA/SET CTB 20C 3S CTB 20C 4S 2 pole 3 pole 4 pole TCF 20GP 3 TCF 20GP 3 TCF 20GP 4 TQQ 12FG ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 4EA, 3 pole 4EA, 4 pole 6EA Molded Case Circuit Breaker_ 73 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UCB250H 42kA UCB250L 50kA Rated current 2 pole Code 3 pole Unit (EA) Code 4 pole Unit (EA) Code Unit (EA) 125A UCB250H 2PT4S0000C 00125 8 UCB250H 3PT4S0000C 00125 8 UCB250H 4PT4S0000C 00125 6 150A UCB250H 2PT4S0000C 00150 8 UCB250H 3PT4S0000C 00150 8 UCB250H 4PT4S0000C 00150 6 160A UCB250H 2PT4S0000C 00160 8 UCB250H 3PT4S0000C 00160 8 UCB250H 4PT4S0000C 00160 6 175A UCB250H 2PT4S0000C 00175 8 UCB250H 3PT4S0000C 00175 8 UCB250H 4PT4S0000C 00175 6 200A UCB250H 2PT4S0000C 00200 8 UCB250H 3PT4S0000C 00200 8 UCB250H 4PT4S0000C 00200 6 225A UCB250H 2PT4S0000C 00225 8 UCB250H 3PT4S0000C 00225 8 UCB250H 4PT4S0000C 00225 6 250A UCB250H 2PT4S0000C 00250 8 UCB250H 3PT4S0000C 00250 8 UCB250H 4PT4S0000C 00250 6 125A UCB250L 2PT4S0000C 00125 8 UCB250L 3PT4S0000C 00125 8 UCB250L 4PT4S0000C 00125 6 150A UCB250L 2PT4S0000C 00150 8 UCB250L 3PT4S0000C 00150 8 UCB250L 4PT4S0000C 00150 6 160A UCB250L 2PT4S0000C 00160 8 UCB250L 3PT4S0000C 00160 8 UCB250L 4PT4S0000C 00160 6 175A UCB250L 2PT4S0000C 00175 8 UCB250L 3PT4S0000C 00175 8 UCB250L 4PT4S0000C 00175 6 200A UCB250L 2PT4S0000C 00200 8 UCB250L 3PT4S0000C 00200 8 UCB250L 4PT4S0000C 00200 6 225A UCB250L 2PT4S0000C 00225 8 UCB250L 3PT4S0000C 00225 8 UCB250L 4PT4S0000C 00225 6 250A UCB250L 2PT4S0000C 00250 8 UCB250L 3PT4S0000C 00250 8 UCB250L 4PT4S0000C 00250 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UCB250H 42kA UCB250L 50kA 74 Rated current 2 pole 3 pole 4 pole Code Unit (EA) Code Unit (EA) 125A UCB250H 2PT5S0000C 00125 8 UCB250H 3PT5S0000C 00125 8 UCB250H 4PT5S0000C 00125 6 150A UCB250H 2PT5S0000C 00150 8 UCB250H 3PT5S0000C 00150 8 UCB250H 4PT5S0000C 00150 6 160A UCB250H 2PT5S0000C 00160 8 UCB250H 3PT5S0000C 00160 8 UCB250H 4PT5S0000C 00160 6 175A UCB250H 2PT5S0000C 00175 8 UCB250H 3PT5S0000C 00175 8 UCB250H 4PT5S0000C 00175 6 200A UCB250H 2PT5S0000C 00200 8 UCB250H 3PT5S0000C 00200 8 UCB250H 4PT5S0000C 00200 6 225A UCB250H 2PT5S0000C 00225 8 UCB250H 3PT5S0000C 00225 8 UCB250H 4PT5S0000C 00225 6 250A UCB250H 2PT5S0000C 00250 8 UCB250H 3PT5S0000C 00250 8 UCB250H 4PT5S0000C 00250 6 125A UCB250L 2PT5S0000C 00125 8 UCB250L 3PT5S0000C 00125 8 UCB250L 4PT5S0000C 00125 6 150A UCB250L 2PT5S0000C 00150 8 UCB250L 3PT5S0000C 00150 8 UCB250L 4PT5S0000C 00150 6 160A UCB250L 2PT5S0000C 00160 8 UCB250L 3PT5S0000C 00160 8 UCB250L 4PT5S0000C 00160 6 175A UCB250L 2PT5S0000C 00175 8 UCB250L 3PT5S0000C 00175 8 UCB250L 4PT5S0000C 00175 6 200A UCB250L 2PT5S0000C 00200 8 UCB250L 3PT5S0000C 00200 8 UCB250L 4PT5S0000C 00200 6 225A UCB250L 2PT5S0000C 00225 8 UCB250L 3PT5S0000C 00225 8 UCB250L 4PT5S0000C 00225 6 250A UCB250L 2PT5S0000C 00250 8 UCB250L 3PT5S0000C 00250 8 UCB250L 4PT5S0000C 00250 6 Code Unit (EA) Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 MCCB �Adjustable thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UCB250H 42kA UCB250L 50kA Rated current 2 pole 3 pole Code Unit (EA) 125A UCB250H 2PT4S0000C 00125F 8 150A UCB250H 2PT4S0000C 00150F 8 160A UCB250H 2PT4S0000C 00160F 175A UCB250H 2PT4S0000C 00175F 200A 225A 4 pole Code Unit (EA) UCB250H 3PT4S0000C 00125F 8 UCB250H 4PT4S0000C 00125F 6 UCB250H 3PT4S0000C 00150F 8 UCB250H 4PT4S0000C 00150F 6 8 UCB250H 3PT4S0000C 00160F 8 UCB250H 4PT4S0000C 00160F 6 8 UCB250H 3PT4S0000C 00175F 8 UCB250H 4PT4S0000C 00175F 6 UCB250H 2PT4S0000C 00200F 8 UCB250H 3PT4S0000C 00200F 8 UCB250H 4PT4S0000C 00200F 6 UCB250H 2PT4S0000C 00225F 8 UCB250H 3PT4S0000C 00225F 8 UCB250H 4PT4S0000C 00225F 6 250A UCB250H 2PT4S0000C 00250F 8 UCB250H 3PT4S0000C 00250F 8 UCB250H 4PT4S0000C 00250F 6 125A UCB250L 2PT4S0000C 00125F 8 UCB250L 3PT4S0000C 00125F 8 UCB250L 4PT4S0000C 00125F 6 150A UCB250L 2PT4S0000C 00150F 8 UCB250L 3PT4S0000C 00150F 8 UCB250L 4PT4S0000C 00150F 6 160A UCB250L 2PT4S0000C 00160F 8 UCB250L 3PT4S0000C 00160F 8 UCB250L 4PT4S0000C 00160F 6 175A UCB250L 2PT4S0000C 00175F 8 UCB250L 3PT4S0000C 00175F 8 UCB250L 4PT4S0000C 00175F 6 200A UCB250L 2PT4S0000C 00200F 8 UCB250L 3PT4S0000C 00200F 8 UCB250L 4PT4S0000C 00200F 6 225A UCB250L 2PT4S0000C 00225F 8 UCB250L 3PT4S0000C 00225F 8 UCB250L 4PT4S0000C 00225F 6 250A UCB250L 2PT4S0000C 00250F 8 UCB250L 3PT4S0000C 00250F 8 UCB250L 4PT4S0000C 00250F 6 Code Unit (EA) Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UCB250H 42kA UCB250L 50kA Rated current 2 pole 3 pole 4 pole Code Unit (EA) Code Unit (EA) Code Unit (EA) 125A UCB250H 2PT5S0000C 00125F 8 UCB250H 3PT5S0000C 00125F 8 UCB250H 4PT5S0000C 00125F 6 150A UCB250H 2PT5S0000C 00150F 8 UCB250H 3PT5S0000C 00150F 8 UCB250H 4PT5S0000C 00150F 6 160A UCB250H 2PT5S0000C 00160F 8 UCB250H 3PT5S0000C 00160F 8 UCB250H 4PT5S0000C 00160F 6 175A UCB250H 2PT5S0000C 00175F 8 UCB250H 3PT5S0000C 00175F 8 UCB250H 4PT5S0000C 00175F 6 200A UCB250H 2PT5S0000C 00200F 8 UCB250H 3PT5S0000C 00200F 8 UCB250H 4PT5S0000C 00200F 6 225A UCB250H 2PT5S0000C 00225F 8 UCB250H 3PT5S0000C 00225F 8 UCB250H 4PT5S0000C 00225F 6 250A UCB250H 2PT5S0000C 00250F 8 UCB250H 3PT5S0000C 00250F 8 UCB250H 4PT5S0000C 00250F 6 125A UCB250L 2PT5S0000C 00125F 8 UCB250L 3PT5S0000C 00125F 8 UCB250L 4PT5S0000C 00125F 6 150A UCB250L 2PT5S0000C 00150F 8 UCB250L 3PT5S0000C 00150F 8 UCB250L 4PT5S0000C 00150F 6 160A UCB250L 2PT5S0000C 00160F 8 UCB250L 3PT5S0000C 00160F 8 UCB250L 4PT5S0000C 00160F 6 175A UCB250L 2PT5S0000C 00175F 8 UCB250L 3PT5S0000C 00175F 8 UCB250L 4PT5S0000C 00175F 6 200A UCB250L 2PT5S0000C 00200F 8 UCB250L 3PT5S0000C 00200F 8 UCB250L 4PT5S0000C 00200F 6 225A UCB250L 2PT5S0000C 00225F 8 UCB250L 3PT5S0000C 00225F 8 UCB250L 4PT5S0000C 00225F 6 250A UCB250L 2PT5S0000C 00250F 8 UCB250L 3PT5S0000C 00250F 8 UCB250L 4PT5S0000C 00250F 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 Molded Case Circuit Breaker_ 75 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UCB type / 400AF | �UCB400R 30kA �UCB400S 42kA �UCB400H 65kA �UCB400L 100kA UCB400R UCB400S UCB400H �2, 3, 4 Number of poles (P) IP20 Degree of protection (without terminal bus bar) Utilization category A Suitability of isolation ○ overload, inst., short-circuit Protection 250,300,320,350,400 Rated current (A) AC690 Rated insulation voltage [Ui] (V) Rating UCB400L AC660 Rated operational voltage [Ue] (V) DC250 Rated impulse withstand voltage [Uimp] (kV) AC600/660V, 50-60Hz Rated short-circuit Ultimate breaking [Icu] capacity (kA r.m.s.) IEC 60947-2 K 60947-2 6 18 22 25 AC480/500V, 50-60Hz 18 25 35 65 AC440/460V, 50-60Hz 25 35 50 85 AC380/415V, 50-60Hz 30 42 65 100 AC220/240V, 50-60Hz 35 50 85 125 DC250V 14 25 40 40 DC125V 20 30 50 60 Service [Ics] % of [Icu] 50 Fixed thermal, Fixed instantaneous Trip mechanism Thermal & Protection magnetic characteristics Adjustable thermal, Fixed instantaneous ○ INST 10×In LTD (0.8-0.9-1)×In INST 10×In ○ Direct mounting by screw Mounting Plug-in Terminal connection Durability (times) Dimensions (mm) ○1) Screw ○ Bus bar ○ 20,000 Electrical operation b ○1) Both line & load side for Switchboard Line side only Mechanical operation a 6,000 a Width 140 /140/185 b Height 257 c Depth 110 d c 2/3/4P d Weight (kg, breaker only) 2/3/4P 2) 145 4/4.5/5.4 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 2) �2P breaker has same dimension as 3P breaker, but the middle pole is removed. 76 30 MCCB ■ Accessories �Signal 1ab, Left-hand-side Auxiliary switch AUX 46D L1 1ab, Left-hand-side Trip alarm switch Shunt trip ALT 46D L1 1) Under voltage trip 2) DC24V DC100-110V AC100-120V AC200-230V AC380-415V SHT 46D A SHT 46D C SHT 46D F SHT 46D H SHT 46D B AC440-480V SHT 46D D DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V �UVT 46D J �UVT 46D L �UVT 46D N �UVT 46D P �UVT 46D Q �UVT 46D R ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. �Operating Power supply direction Operating Surface S type handle 1) Extended S type Motor operator 2) Upper Right Left TFG 46DS U2 TFG 46DS R2 TFG 46DS L2 DC24V AC/DC110V AC/DC220V MOT 40D DC24 MOT 40D ADC110 MOT 40D ADC220 2 pole 3 pole 4 pole MIF 40D 3 MIF 40D 3 MIF 40D 4 TFH 46DS Mechanical interlock Extension handle 3) THA 46D ※ 1) For detail type information, please refer to page no. 201-209. 2) Motor operator is not recommended for marine application. 3) Supplied as standard component �Mounting Structure Plug-in 1) Mounting base Connection 2C contact block 2) 5C contact For both line & load side For line side only TDM 4BA 3) TDM 4BA TYA 5/2 4) - 4) - TYA 5/5 ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. 3) 2EA are required for both line & load side plug-in type 3P breaker. 4) TYA type connection blocks are to be installed with separate mounting angle. Separate mounting angle is not supplied. �Terminal 2 pole (4EA/SET) 3 pole (6EA/SET) 4 pole (8EA/SET) Terminal bus bar TBB 4S 2 Cage terminal block 2EA/SET TBB 4S 4 4EA/SET CTB 40D 3S Terminal cover 1) Interpole barrier 2) TBB 4S 3 3EA/SET CTB 40D 4S 2 pole 3 pole 4 pole TCF 40D 3 TCF 40D 3 TCF 40D 4 TQQ 4BA ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 4EA, 3 pole 4EA, 4 pole 6EA Molded Case Circuit Breaker_ 77 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UCB400R 30kA UCB400S 42kA UCB400H 65kA UCB400L 100kA Rated current 2 pole Code Unit (EA) 3 pole Code Unit (EA) 4 pole Code Unit (EA) 250A UCB400R 2PT4S0000C 00250 3 UCB400R 3PT4S0000C 00250 3 UCB400R 4PT4S0000C 00250 2 300A UCB400R 2PT4S0000C 00300 3 UCB400R 3PT4S0000C 00300 3 UCB400R 4PT4S0000C 00300 2 320A UCB400R 2PT4S0000C 00320 3 UCB400R 3PT4S0000C 00320 3 UCB400R 4PT4S0000C 00320 2 350A UCB400R 2PT4S0000C 00350 3 UCB400R 3PT4S0000C 00350 3 UCB400R 4PT4S0000C 00350 2 400A UCB400R 2PT4S0000C 00400 3 UCB400R 3PT4S0000C 00400 3 UCB400R 4PT4S0000C 00400 2 250A UCB400S 2PT4S0000C 00250 3 UCB400S 3PT4S0000C 00250 3 UCB400S 4PT4S0000C 00250 2 300A UCB400S 2PT4S0000C 00300 3 UCB400S 3PT4S0000C 00300 3 UCB400S 4PT4S0000C 00300 2 320A UCB400S 2PT4S0000C 00320 3 UCB400S 3PT4S0000C 00320 3 UCB400S 4PT4S0000C 00320 2 350A UCB400S 2PT4S0000C 00350 3 UCB400S 3PT4S0000C 00350 3 UCB400S 4PT4S0000C 00350 2 400A UCB400S 2PT4S0000C 00400 3 UCB400S 3PT4S0000C 00400 3 UCB400S 4PT4S0000C 00400 2 250A UCB400H 2PT4S0000C 00250 3 UCB400H 3PT4S0000C 00250 3 UCB400H 4PT4S0000C 00250 2 300A UCB400H 2PT4S0000C 00300 3 UCB400H 3PT4S0000C 00300 3 UCB400H 4PT4S0000C 00300 2 320A UCB400H 2PT4S0000C 00320 3 UCB400H 3PT4S0000C 00320 3 UCB400H 4PT4S0000C 00320 2 350A UCB400H 2PT4S0000C 00350 3 UCB400H 3PT4S0000C 00350 3 UCB400H 4PT4S0000C 00350 2 400A UCB400H 2PT4S0000C 00400 3 UCB400H 3PT4S0000C 00400 3 UCB400H 4PT4S0000C 00400 2 250A UCB400L 2PT4S0000C 00250 3 UCB400L 3PT4S0000C 00250 3 UCB400L 4PT4S0000C 00250 2 300A UCB400L 2PT4S0000C 00300 3 UCB400L 3PT4S0000C 00300 3 UCB400L 4PT4S0000C 00300 2 320A UCB400L 2PT4S0000C 00320 3 UCB400L 3PT4S0000C 00320 3 UCB400L 4PT4S0000C 00320 2 350A UCB400L 2PT4S0000C 00350 3 UCB400L 3PT4S0000C 00350 3 UCB400L 4PT4S0000C 00350 2 400A UCB400L 2PT4S0000C 00400 3 UCB400L 3PT4S0000C 00400 3 UCB400L 4PT4S0000C 00400 2 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UCB400R 30kA UCB400S 42kA UCB400H 65kA UCB400L 100kA 78 Rated current 2 pole Code Unit (EA) 3 pole Code Unit (EA) 4 pole Code Unit (EA) 250A UCB400R 2PT5S0000C 00250 3 UCB400R 3PT5S0000C 00250 3 UCB400R 4PT5S0000C 00250 2 300A UCB400R 2PT5S0000C 00300 3 UCB400R 3PT5S0000C 00300 3 UCB400R 4PT5S0000C 00300 2 320A UCB400R 2PT5S0000C 00320 3 UCB400R 3PT5S0000C 00320 3 UCB400R 4PT5S0000C 00320 2 350A UCB400R 2PT5S0000C 00350 3 UCB400R 3PT5S0000C 00350 3 UCB400R 4PT5S0000C 00350 2 400A UCB400R 2PT5S0000C 00400 3 UCB400R 3PT5S0000C 00400 3 UCB400R 4PT5S0000C 00400 2 250A UCB400S 2PT5S0000C 00250 3 UCB400S 3PT5S0000C 00250 3 UCB400S 4PT5S0000C 00250 2 300A UCB400S 2PT5S0000C 00300 3 UCB400S 3PT5S0000C 00300 3 UCB400S 4PT5S0000C 00300 2 320A UCB400S 2PT5S0000C 00320 3 UCB400S 3PT5S0000C 00320 3 UCB400S 4PT5S0000C 00320 2 350A UCB400S 2PT5S0000C 00350 3 UCB400S 3PT5S0000C 00350 3 UCB400S 4PT5S0000C 00350 2 400A UCB400S 2PT5S0000C 00400 3 UCB400S 3PT5S0000C 00400 3 UCB400S 4PT5S0000C 00400 2 250A UCB400H 2PT5S0000C 00250 3 UCB400H 3PT5S0000C 00250 3 UCB400H 4PT5S0000C 00250 2 300A UCB400H 2PT5S0000C 00300 3 UCB400H 3PT5S0000C 00300 3 UCB400H 4PT5S0000C 00300 2 320A UCB400H 2PT5S0000C 00320 3 UCB400H 3PT5S0000C 00320 3 UCB400H 4PT5S0000C 00320 2 350A UCB400H 2PT5S0000C 00350 3 UCB400H 3PT5S0000C 00350 3 UCB400H 4PT5S0000C 00350 2 400A UCB400H 2PT5S0000C 00400 3 UCB400H 3PT5S0000C 00400 3 UCB400H 4PT5S0000C 00400 2 250A UCB400L 2PT5S0000C 00250 3 UCB400L 3PT5S0000C 00250 3 UCB400L 4PT5S0000C 00250 2 300A UCB400L 2PT5S0000C 00300 3 UCB400L 3PT5S0000C 00300 3 UCB400L 4PT5S0000C 00300 2 320A UCB400L 2PT5S0000C 00320 3 UCB400L 3PT5S0000C 00320 3 UCB400L 4PT5S0000C 00320 2 350A UCB400L 2PT5S0000C 00350 3 UCB400L 3PT5S0000C 00350 3 UCB400L 4PT5S0000C 00350 2 400A UCB400L 2PT5S0000C 00400 3 UCB400L 3PT5S0000C 00400 3 UCB400L 4PT5S0000C 00400 2 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 MCCB �Adjustable thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UCB400R 30kA UCB400S 42kA UCB400H 65kA UCB400L 100kA Rated current 2 pole Code Unit (EA) 3 pole Code Unit (EA) 4 pole Code Unit (EA) 250A UCB400R 2PT4S0000C 00250F 3 UCB400R 3PT4S0000C 00250F 3 UCB400R 4PT4S0000C 00250F 2 300A UCB400R 2PT4S0000C 00300F 3 UCB400R 3PT4S0000C 00300F 3 UCB400R 4PT4S0000C 00300F 2 320A UCB400R 2PT4S0000C 00320F 3 UCB400R 3PT4S0000C 00320F 3 UCB400R 4PT4S0000C 00320F 2 350A UCB400R 2PT4S0000C 00350F 3 UCB400R 3PT4S0000C 00350F 3 UCB400R 4PT4S0000C 00350F 2 400A UCB400R 2PT4S0000C 00400F 3 UCB400R 3PT4S0000C 00400F 3 UCB400R 4PT4S0000C 00400F 2 250A UCB400S 2PT4S0000C 00250F 3 UCB400S 3PT4S0000C 00250F 3 UCB400S 4PT4S0000C 00250F 2 300A UCB400S 2PT4S0000C 00300F 3 UCB400S 3PT4S0000C 00300F 3 UCB400S 4PT4S0000C 00300F 2 320A UCB400S 2PT4S0000C 00320F 3 UCB400S 3PT4S0000C 00320F 3 UCB400S 4PT4S0000C 00320F 2 350A UCB400S 2PT4S0000C 00350F 3 UCB400S 3PT4S0000C 00350F 3 UCB400S 4PT4S0000C 00350F 2 400A UCB400S 2PT4S0000C 00400F 3 UCB400S 3PT4S0000C 00400F 3 UCB400S 4PT4S0000C 00400F 2 250A UCB400H 2PT4S0000C 00250F 3 UCB400H 3PT4S0000C 00250F 3 UCB400H 4PT4S0000C 00250F 2 300A UCB400H 2PT4S0000C 00300F 3 UCB400H 3PT4S0000C 00300F 3 UCB400H 4PT4S0000C 00300F 2 320A UCB400H 2PT4S0000C 00320F 3 UCB400H 3PT4S0000C 00320F 3 UCB400H 4PT4S0000C 00320F 2 350A UCB400H 2PT4S0000C 00350F 3 UCB400H 3PT4S0000C 00350F 3 UCB400H 4PT4S0000C 00350F 2 400A UCB400H 2PT4S0000C 00400F 3 UCB400H 3PT4S0000C 00400F 3 UCB400H 4PT4S0000C 00400F 2 250A UCB400L 2PT4S0000C 00250F 3 UCB400L 3PT4S0000C 00250F 3 UCB400L 4PT4S0000C 00250F 2 300A UCB400L 2PT4S0000C 00300F 3 UCB400L 3PT4S0000C 00300F 3 UCB400L 4PT4S0000C 00300F 2 320A UCB400L 2PT4S0000C 00320F 3 UCB400L 3PT4S0000C 00320F 3 UCB400L 4PT4S0000C 00320F 2 350A UCB400L 2PT4S0000C 00350F 3 UCB400L 3PT4S0000C 00350F 3 UCB400L 4PT4S0000C 00350F 2 400A UCB400L 2PT4S0000C 00400F 3 UCB400L 3PT4S0000C 00400F 3 UCB400L 4PT4S0000C 00400F 2 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UCB400R 30kA UCB400S 42kA UCB400H 65kA UCB400L 100kA Rated current 2 pole Code Unit (EA) 3 pole Code Unit (EA) 4 pole Code Unit (EA) Specification Category 250A UCB400R 2PT5S0000C 00250F 3 UCB400R 3PT5S0000C 00250F 3 UCB400R 4PT5S0000C 00250F 2 300A UCB400R 2PT5S0000C 00300F 3 UCB400R 3PT5S0000C 00300F 3 UCB400R 4PT5S0000C 00300F 2 320A UCB400R 2PT5S0000C 00320F 3 UCB400R 3PT5S0000C 00320F 3 UCB400R 4PT5S0000C 00320F 2 350A UCB400R 2PT5S0000C 00350F 3 UCB400R 3PT5S0000C 00350F 3 UCB400R 4PT5S0000C 00350F 2 400A UCB400R 2PT5S0000C 00400F 3 UCB400R 3PT5S0000C 00400F 3 UCB400R 4PT5S0000C 00400F 2 250A UCB400S 2PT5S0000C 00250F 3 UCB400S 3PT5S0000C 00250F 3 UCB400S 4PT5S0000C 00250F 2 300A UCB400S 2PT5S0000C 00300F 3 UCB400S 3PT5S0000C 00300F 3 UCB400S 4PT5S0000C 00300F 2 320A UCB400S 2PT5S0000C 00320F 3 UCB400S 3PT5S0000C 00320F 3 UCB400S 4PT5S0000C 00320F 2 350A UCB400S 2PT5S0000C 00350F 3 UCB400S 3PT5S0000C 00350F 3 400A UCB400S 2PT5S0000C 00400F 3 UCB400S 3PT5S0000C 00400F 3 250A UCB400H 2PT5S0000C 00250F 3 UCB400H 3PT5S0000C 00250F 3 300A UCB400H 2PT5S0000C 00300F 3 UCB400H 3PT5S0000C 00300F 3 320A UCB400H 2PT5S0000C 00320F 3 UCB400H 3PT5S0000C 00320F 3 Screw type terminal UCB400S 4PT5S0000C 00400F 2 connection, UCB400H 4PT5S0000C 00250F 2 No option, UCB400H 4PT5S0000C 00300F 2 50/60Hz UCB400H 4PT5S0000C 00320F 2 350A UCB400H 2PT5S0000C 00350F 3 UCB400H 3PT5S0000C 00350F 3 UCB400H 4PT5S0000C 00350F 2 400A UCB400H 2PT5S0000C 00400F 3 UCB400H 3PT5S0000C 00400F 3 UCB400H 4PT5S0000C 00400F 2 250A UCB400L 2PT5S0000C 00250F 3 UCB400L 3PT5S0000C 00250F 3 UCB400L 4PT5S0000C 00250F 2 300A UCB400L 2PT5S0000C 00300F 3 UCB400L 3PT5S0000C 00300F 3 UCB400L 4PT5S0000C 00300F 2 320A UCB400L 2PT5S0000C 00320F 3 UCB400L 3PT5S0000C 00320F 3 UCB400L 4PT5S0000C 00320F 2 350A UCB400L 2PT5S0000C 00350F 3 UCB400L 3PT5S0000C 00350F 3 UCB400L 4PT5S0000C 00350F 2 400A UCB400L 2PT5S0000C 00400F 3 UCB400L 3PT5S0000C 00400F 3 UCB400L 4PT5S0000C 00400F 2 UCB400S 4PT5S0000C 00350F 2 MCCB /M2 Molded Case Circuit Breaker_ 79 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UCB type / 630AF | �UCB630R 45kA �UCB630S 65kA �UCB630H 85kA �UCB630L 100kA UCB630R UCB630S UCB630H �2, 3, 4 Number of poles (P) IP20 Degree of protection (without terminal bus bar) Utilization category A Suitability of isolation ○ overload, inst., short-circuit Protection 500, 630 Rated current (A) AC690 Rated insulation voltage [Ui] (V) Rating UCB630L AC660 Rated operational voltage [Ue] (V) DC250 Rated impulse withstand voltage [Uimp] (kV) 22 AC600/660V, 50-60Hz Rated short-circuit Ultimate breaking [Icu] capacity (kA r.m.s.) IEC 60947-2 K 60947-2 6 25 35 AC480/500V, 50-60Hz 25 45 50 65 AC440/460V, 50-60Hz 35 50 65 85 AC380/415V, 50-60Hz 45 65 85 100 AC220/240V, 50-60Hz 50 100 100 125 DC250V 20 40 40 40 DC125V 30 50 50 60 Service [Ics] % of [Icu] 50 Fixed thermal, Fixed instantaneous Trip mechanism Thermal & Protection magnetic characteristics Adjustable thermal, Fixed instantaneous ○ INST 10×In LTD (0.8-0.9-1)×In INST 10×In ○ Direct mounting by screw Mounting Plug-in Terminal connection Durability (times) Dimensions (mm) ○1) Screw ○ Bus bar ○ 20,000 Electrical operation b ○1) Both line & load side for Switchboard Line side only Mechanical operation a 6,000 a Width 210 /210/280 b Height 280 c Depth 110 d c 2/3/4P d Weight (kg, breaker only) 2/3/4P 2) 145 8.7/9.5/12.5 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 2)�2P breaker has same dimension as 3P breaker, but the middle pole is removed. 80 35 MCCB ■ Accessories �Signal 1ab, Left-hand-side Auxiliary switch AUX 46D L1 1ab, Left-hand-side Trip alarm switch ALT 46D L1 Shunt trip 1) Under voltage trip 2) DC24V DC100-110V AC100-120V AC200-230V AC380-415V SHT 46D A SHT 46D C SHT 46D F SHT 46D H SHT 46D B AC440-480V SHT 46D D DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V �UVT 46D J �UVT 46D L �UVT 46D N �UVT 46D P �UVT 46D Q �UVT 46D R ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. �Operating Power supply direction Operating Surface S type handle 1) Extended S type Upper Right Left TFG 46DS U2 TFG 46DS R2 TFG 46DS L2 TFH 46DS Motor operator 2) DC24V AC/DC110V AC/DC220V MOT 68E DC24 MOT 68E ADC110 MOT 68E ADC220 Mechanical interlock 2 pole 3 pole 4 pole MIF 80E 3 MIF 80E 3 MIF 80E 4 Extension handle 3) THA 46D ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. 3) Supplied as standard component �Mounting Structure Plug-in 1) For both line & load side For line side only TDM 5BA 3) TDM 5BA Mounting base Connection 2C contact TYA 5/2 4) - block 2) TYA 5/5 4) - 5C contact ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. 3) 2EA are required for both line & load side plug-in type 3P breaker. 4) TYA type connection blocks are to be installed with separate mounting angle. Separate mounting angle is not supplied. �Terminal 2 pole (4EA/SET) 3 pole (6EA/SET) 4 pole (8EA/SET) Terminal bus bar TBB 6S 2 Cage terminal block Terminal cover 1) Interpole barrier 2) TBB 6S 3 TBB 6S 4 3EA/SET 4EA/SET CTB 80E 3S CTB 80E 4S 2 pole 3 pole 4 pole TCF 80E 3 TCF 80E 3 TCF 80E 4 2EA/SET TQQ 5BA ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 4EA, 3 pole 4EA, 4 pole 6EA ■ Standard order code and unit ※Please refer to page 84. Molded Case Circuit Breaker_ 81 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UCB type / 800AF | �UCB800R 45kA �UCB800S 65kA �UCB800H 85kA �UCB800L 100kA UCB800R UCB800S UCB800H �2, 3, 4 Number of poles (P) IP20 Degree of protection (without terminal bus bar) Utilization category A Suitability of isolation ○ overload, inst., short-circuit Protection 700, 800 Rated current (A) AC690 Rated insulation voltage [Ui] (V) Rating UCB800L AC660 Rated operational voltage [Ue] (V) DC250 Rated impulse withstand voltage [Uimp] (kV) 6 25 AC600/660V, 50-60Hz 25 35 Rated short-circuit Ultimate breaking [Icu] capacity (kA r.m.s.) AC480/500V, 50-60Hz 35 45 50 65 AC440/460V, 50-60Hz 35 50 65 85 AC380/415V, 50-60Hz 45 65 85 100 AC220/240V, 50-60Hz 50 100 100 125 IEC 60947-2 K 60947-2 DC250V 20 40 40 40 DC125V 30 50 50 60 Service [Ics] % of [Icu] 50 Fixed thermal, Fixed instantaneous Trip mechanism Thermal & Protection magnetic characteristics Adjustable thermal, Fixed instantaneous ○ INST 10×In LTD (0.8-0.9-1)×In INST 10×In ○ Direct mounting by screw Mounting Plug-in Terminal connection Durability (times) Dimensions (mm) ○1) Screw ○ Bus bar ○ 10,000 Electrical operation b ○1) Both line & load side for Switchboard Line side only Mechanical operation a 3,000 a Width 210 /210/280 b Height 280 c Depth 110 d c 2/3/4P d Weight (kg, breaker only) 2/3/4P 2) 145 8.7/9.5/12.5 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) Available for 3P breaker 2)�2P breaker has same dimension as 3P breaker, but the middle pole is removed. 82 35 MCCB ■ Accessories �Signal 1ab, Left-hand-side Auxiliary switch AUX 46D L1 1ab, Left-hand-side Trip alarm switch Shunt trip ALT 46D L1 1) Under voltage trip 2) DC24V DC100-110V AC100-120V AC200-230V AC380-415V SHT 46D A SHT 46D C SHT 46D F SHT 46D H SHT 46D B AC440-480V SHT 46D D DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V �UVT 46D J �UVT 46D L �UVT 46D N �UVT 46D P �UVT 46D Q �UVT 46D R ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. �Operating Power supply direction Operating Surface S type handle1) Extended S type Upper Right Left TFG 46DS U2 TFG 46DS R2 TFG 46DS L2 TFH 46DS Motor operator 2) DC24V AC/DC110V AC/DC220V MOT 68E DC24 MOT 68E ADC110 MOT 68E ADC220 Mechanical interlock 2 pole 3 pole 4 pole MIF 80E 3 MIF 80E 3 MIF 80E 4 Extension handle 3) THA 46D ※ 1) For detail type information, please refer to page no. 201-209. 2) Motor operator is not recommended for marine application. 3) Supplied as standard component �Mounting Structure Plug-in 1) For both line & load side For line side only TDM 5BA 3) TDM 5BA Mounting base Connection 2C contact TYA 5/2 4) - block 2) TYA 5/5 4) - 5C contact ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. 3) 2EA are required for both line & load side plug-in type 3p breaker. 4) TYA type connection blocks are to be installed with separate mounting angle. Separate mounting angle is not supplied. �Terminal 2 pole (4EA/SET) 3 pole (6EA/SET) 4 pole (8EA/SET) Terminal bus bar TBB 8S 2 Cage terminal block Terminal cover 1) Interpole barrier 2) TBB 8S 3 TBB 8S 4 3EA/SET 4EA/SET CTB 80E 3S CTB 80E 4S 2 pole 3 pole 4 pole TCF 80E 3 TCF 80E 3 TCF 80E 4 2EA/SET TQQ 5BA ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 4EA, 3 pole 4EA, 4 pole 6EA ■ Standard order code and unit ※Please refer to page 85. Molded Case Circuit Breaker_ 83 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit / UCB type 630AF �Fixed thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V Rated current 2 pole Code 3 pole Unit (EA) Code 4 pole Unit (EA) Code Unit (EA) UCB630R 45kA 500A UCB630R 2PT4S0000C 00500 2 UCB630R 3PT4S0000C 00500 2 UCB630R 4PT4S0000C 00500 1 630A UCB630R 2PT4S0000C 00630 2 UCB630R 3PT4S0000C 00630 2 UCB630R 4PT4S0000C 00630 1 UCB630S 65kA 500A UCB630S 2PT4S0000C 00500 2 UCB630S 3PT4S0000C 00500 2 UCB630S 4PT4S0000C 00500 1 630A UCB630S 2PT4S0000C 00630 2 UCB630S 3PT4S0000C 00630 2 UCB630S 4PT4S0000C 00630 1 UCB630H 85kA 500A UCB630H 2PT4S0000C 00500 2 UCB630H 3PT4S0000C 00500 2 UCB630H 4PT4S0000C 00500 1 630A UCB630H 2PT4S0000C 00630 2 UCB630H 3PT4S0000C 00630 2 UCB630H 4PT4S0000C 00630 1 UCB630L 100kA 500A UCB630L 2PT4S0000C 00500 2 UCB630L 3PT4S0000C 00500 2 UCB630L 4PT4S0000C 00500 1 630A UCB630L 2PT4S0000C 00630 2 UCB630L 3PT4S0000C 00630 2 UCB630L 4PT4S0000C 00630 1 2 pole 3 pole Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V Rated current Code Unit (EA) Code 4 pole Unit (EA) Code Unit (EA) UCB630R 45kA 500A UCB630R 2PT5S0000C 00500 2 UCB630R 3PT5S0000C 00500 2 UCB630R 4PT5S0000C 00500 1 630A UCB630R 2PT5S0000C 00630 2 UCB630R 3PT5S0000C 00630 2 UCB630R 4PT5S0000C 00630 1 UCB630S 65kA 500A UCB630S 2PT5S0000C 00500 2 UCB630S 3PT5S0000C 00500 2 UCB630S 4PT5S0000C 00500 1 630A UCB630S 2PT5S0000C 00630 2 UCB630S 3PT5S0000C 00630 2 UCB630S 4PT5S0000C 00630 1 UCB630H 85kA 500A UCB630H 2PT5S0000C 00500 2 UCB630H 3PT5S0000C 00500 2 UCB630H 4PT5S0000C 00500 1 630A UCB630H 2PT5S0000C 00630 2 UCB630H 3PT5S0000C 00630 2 UCB630H 4PT5S0000C 00630 1 UCB630L 100kA 500A UCB630L 2PT5S0000C 00500 2 UCB630L 3PT5S0000C 00500 2 UCB630L 4PT5S0000C 00500 1 630A UCB630L 2PT5S0000C 00630 2 UCB630L 3PT5S0000C 00630 2 UCB630L 4PT5S0000C 00630 1 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 �Adjustable thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V Rated current 2 pole Code 3 pole Unit (EA) Code 4 pole Unit (EA) Code Unit (EA) UCB630R 45kA 500A UCB630R 2PT4S0000C 00500F 2 UCB630R 3PT4S0000C 00500F 2 UCB630R 4PT4S0000C 00500F 1 630A UCB630R 2PT4S0000C 00630F 2 UCB630R 3PT4S0000C 00630F 2 UCB630R 4PT4S0000C 00630F 1 UCB630S 65kA 500A UCB630S 2PT4S0000C 00500F 2 UCB630S 3PT4S0000C 00500F 2 UCB630S 4PT4S0000C 00500F 1 630A UCB630S 2PT4S0000C 00630F 2 UCB630S 3PT4S0000C 00630F 2 UCB630S 4PT4S0000C 00630F 1 UCB630H 85kA 500A UCB630H 2PT4S0000C 00500F 2 UCB630H 3PT4S0000C 00500F 2 UCB630H 4PT4S0000C 00500F 1 630A UCB630H 2PT4S0000C 00630F 2 UCB630H 3PT4S0000C 00630F 2 UCB630H 4PT4S0000C 00630F 1 UCB630L 100kA 500A UCB630L 2PT4S0000C 00500F 2 UCB630L 3PT4S0000C 00500F 2 UCB630L 4PT4S0000C 00500F 1 630A UCB630L 2PT4S0000C 00630F 2 UCB630L 3PT4S0000C 00630F 2 UCB630L 4PT4S0000C 00630F 1 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V 84 Rated current 2 pole Code 3 pole Unit (EA) Code 4 pole Unit (EA) Code Unit (EA) UCB630R 45kA 500A UCB630R 2PT5S0000C 00500F 2 UCB630R 3PT5S0000C 00500F 2 630A UCB630R 2PT5S0000C 00630F 2 UCB630R 3PT5S0000C 00630F 2 UCB630R 4PT5S0000C 00630F 1 UCB630S 65kA 500A UCB630S 2PT5S0000C 00500F 2 UCB630S 3PT5S0000C 00500F 2 UCB630S 4PT5S0000C 00500F 1 630A UCB630S 2PT5S0000C 00630F 2 UCB630S 3PT5S0000C 00630F 2 UCB630S 4PT5S0000C 00630F 1 UCB630H 85kA 500A UCB630H 2PT5S0000C 00500F 2 UCB630H 3PT5S0000C 00500F 2 UCB630H 4PT5S0000C 00500F 1 630A UCB630H 2PT5S0000C 00630F 2 UCB630H 3PT5S0000C 00630F 2 UCB630H 4PT5S0000C 00630F 1 UCB630L 100kA 500A UCB630L 2PT5S0000C 00500F 2 UCB630L 3PT5S0000C 00500F 2 UCB630L 4PT5S0000C 00500F 1 630A UCB630L 2PT5S0000C 00630F 2 UCB630L 3PT5S0000C 00630F 2 UCB630L 4PT5S0000C 00630F 1 Specification Category UCB630R 4PT5S0000C 00500F 1 Screw type terminal connection, No option, 50/60Hz MCCB /M2 MCCB ■ Standard order code and unit / UCB type 800AF �Fixed thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V Rated current 2 pole 3 pole Code Unit (EA) Code 4 pole Unit (EA) Code Unit (EA) UCB800R 45kA 700A UCB800R 2PT4S0000C 00700 2 UCB800R 3PT4S0000C 00700 2 UCB800R 4PT4S0000C 00700 1 800A UCB800R 2PT4S0000C 00800 2 UCB800R 3PT4S0000C 00800 2 UCB800R 4PT4S0000C 00800 1 UCB800S 65kA 700A UCB800S 2PT4S0000C 00700 2 UCB800S 3PT4S0000C 00700 2 UCB800S 4PT4S0000C 00700 1 800A UCB800S 2PT4S0000C 00800 2 UCB800S 3PT4S0000C 00800 2 UCB800S 4PT4S0000C 00800 1 UCB800H 85kA 700A UCB800H 2PT4S0000C 00700 2 UCB800H 3PT4S0000C 00700 2 UCB800H 4PT4S0000C 00700 1 800A UCB800H 2PT4S0000C 00800 2 UCB800H 3PT4S0000C 00800 2 UCB800H 4PT4S0000C 00800 1 UCB800L 100kA 700A UCB800L 2PT4S0000C 00700 2 UCB800L 3PT4S0000C 00700 2 UCB800L 4PT4S0000C 00700 1 800A UCB800L 2PT4S0000C 00800 2 UCB800L 3PT4S0000C 00800 2 UCB800L 4PT4S0000C 00800 1 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V Rated current 2 pole 3 pole Code Unit (EA) Code 4 pole Unit (EA) Code Unit (EA) UCB800R 45kA 700A UCB800R 2PT5S0000C 00700 2 UCB800R 3PT5S0000C 00700 2 UCB800R 4PT5S0000C 00700 1 800A UCB800R 2PT5S0000C 00800 2 UCB800R 3PT5S0000C 00800 2 UCB800R 4PT5S0000C 00800 1 UCB800S 65kA 700A UCB800S 2PT5S0000C 00700 2 UCB800S 3PT5S0000C 00700 2 UCB800S 4PT5S0000C 00700 1 800A UCB800S 2PT5S0000C 00800 2 UCB800S 3PT5S0000C 00800 2 UCB800S 4PT5S0000C 00800 1 UCB800H 85kA 700A UCB800H 2PT5S0000C 00700 2 UCB800H 3PT5S0000C 00700 2 UCB800H 4PT5S0000C 00700 1 800A UCB800H 2PT5S0000C 00800 2 UCB800H 3PT5S0000C 00800 2 UCB800H 4PT5S0000C 00800 1 UCB800L 100kA 700A UCB800L 2PT5S0000C 00700 2 UCB800L 3PT5S0000C 00700 2 UCB800L 4PT5S0000C 00700 1 800A UCB800L 2PT5S0000C 00800 2 UCB800L 3PT5S0000C 00800 2 UCB800L 4PT5S0000C 00800 1 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 �Adjustable thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V Rated current 2 pole Code 3 pole Unit (EA) Code 4 pole Unit (EA) Code Unit (EA) UCB800R 45kA 700A UCB800R 2PT4S0000C 00700F 2 UCB800R 3PT4S0000C 00700F 2 UCB800R 4PT4S0000C 00700F 1 800A UCB800R 2PT4S0000C 00800F 2 UCB800R 3PT4S0000C 00800F 2 UCB800R 4PT4S0000C 00800F 1 UCB800S 65kA 700A UCB800S 2PT4S0000C 00700F 2 UCB800S 3PT4S0000C 00700F 2 UCB800S 4PT4S0000C 00700F 1 800A UCB800S 2PT4S0000C 00800F 2 UCB800S 3PT4S0000C 00800F 2 UCB800S 4PT4S0000C 00800F 1 UCB800H 85kA 700A UCB800H 2PT4S0000C 00700F 2 UCB800H 3PT4S0000C 00700F 2 UCB800H 4PT4S0000C 00700F 1 800A UCB800H 2PT4S0000C 00800F 2 UCB800H 3PT4S0000C 00800F 2 UCB800H 4PT4S0000C 00800F 1 UCB800L 100kA 700A UCB800L 2PT4S0000C 00700F 2 UCB800L 3PT4S0000C 00700F 2 UCB800L 4PT4S0000C 00700F 1 800A UCB800L 2PT4S0000C 00800F 2 UCB800L 3PT4S0000C 00800F 2 UCB800L 4PT4S0000C 00800F 1 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V Rated current 2 pole Code 3 pole Unit (EA) Code 4 pole Unit (EA) Code Unit (EA) UCB800R 45kA 700A UCB800R 2PT5S0000C 00700F 2 UCB800R 3PT5S0000C 00700F 2 800A UCB800R 2PT5S0000C 00800F 2 UCB800R 3PT5S0000C 00800F 2 UCB800R 4PT5S0000C 00800F 1 UCB800S 65kA 700A UCB800S 2PT5S0000C 00700F 2 UCB800S 3PT5S0000C 00700F 2 UCB800S 4PT5S0000C 00700F 1 800A UCB800S 2PT5S0000C 00800F 2 UCB800S 3PT5S0000C 00800F 2 UCB800S 4PT5S0000C 00800F 1 UCB800H 85kA 700A UCB800H 2PT5S0000C 00700F 2 UCB800H 3PT5S0000C 00700F 2 UCB800H 4PT5S0000C 00700F 1 800A UCB800H 2PT5S0000C 00800F 2 UCB800H 3PT5S0000C 00800F 2 UCB800H 4PT5S0000C 00800F 1 UCB800L 100kA 700A UCB800L 2PT5S0000C 00700F 2 UCB800L 3PT5S0000C 00700F 2 UCB800L 4PT5S0000C 00700F 1 800A UCB800L 2PT5S0000C 00800F 2 UCB800L 3PT5S0000C 00800F 2 UCB800L 4PT5S0000C 00800F 1 Specification Category UCB800R 4PT5S0000C 00700F 1 Screw type terminal connection, No option, 50/60Hz MCCB /M2 Molded Case Circuit Breaker_ 85 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UCB type / 1000AF | �UCB1000S 100kA �UCB1000L 130kA UCB1000S UCB1000L Number of poles (P) 3, 4 Degree of protection (without terminal bus bar) IP20 Utilization category A Suitability of isolation ○ Protection overload, inst., short-circuit Rated current (A) 505-1,000 Rated insulation voltage [Ui] (V) AC750 Rated operational voltage [Ue] (V) AC690 Rating Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit breaking capacity Ultimate [Icu] (kA r.m.s.) IEC 60947-2 K 60947-2 8 AC600/660V, 50-60Hz 40 60 AC480/500V, 50-60Hz 75 100 AC440/460V, 50-60Hz 75 100 AC380/415V, 50-60Hz 100 130 AC220/240V, 50-60Hz 100 150 Service [Ics] % of [Icu] Trip mechanism Electronic & Protection characteristics Mounting LTD (0.5-1) ×In (15 setting) Short time delay STD (2-4-6-8-10)×Ir Instantaneous INST (3-6-8-10-11)×In Ground fault trip GFT (0.2-0.3-0.4)×In Pre-trip alarm PTA 0.9×In I2T lamp ○ Pick-up LED ○ ○ ○ Bus bar Mechanical operation 10,000 Electrical operation 3,000 a Dimensions (mm) Long time delay Direct mounting by screw Terminal connection Durability (times) 50 1) d c 3/4P b a Width 210/280 b Height 370 c Depth 110/200 d Weight (kg, breaker only) 3/4P 159/249 13/17 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) (0.5-1): (0.63-0.8-1)x(0.8-0.85-0.9-0.95-1) 86 25/33 MCCB ■ Accessories �Signal 1ab, Right-hand-side 2ab, Right-hand-side 3ab, Right-hand-side Auxiliary switch AUX 80NE R1 Trip alarm switch Shunt trip AUX 80NE R2 AUX 80NE R3 1ab, Right-hand-side ALT 80NE R1 DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V SHT 120NE A SHT 120NE C SHT 120NE F SHT 120NE H SHT 120NE B SHT 120NE D 1) Under voltage trip 2) DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V UVT 120NE J UVT 120NE L UVT 120NE N UVT 120NE P UVT 120NE Q UVT 120NE R ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Operating Motor operator 1) DC24V AC/DC110V AC/DC220V MOT 80NE DC24 MOT 80NE ADC110 MOT 80NE ADC220 Extension handle 2) THA 80NE ※ 1) Motor operator is not recommended for marine application. 2) Supplied as standard component �Terminal Interpole barrier 1) 4EA/SET TQQ 80NE ※1) Supplied as standard component Required quantity for both line and load side of breaker: 3 pole 4EA, 4 pole 6EA ■ Standard order code and unit �Electronic - LTD, STD, INST trip Model / Breaking capacity at AC380/415V 표준품 주문코드 Rated current UCB1000S 100kA 1000A UCB1000S 3PESB0000X 01000 3 pole Code 4 pole Unit (EA) 1 Code UCB1000S 4PESB0000X 01000 Unit (EA) 1 UCB1000L 130kA 1000A UCB1000L 3PESB0000X 01000 1 UCB1000L 4PESB0000X 01000 1 UCB1000S 100kA 1000A UCB1000S 3PESB0000Y 01000 1 UCB1000S 4PESB0000Y 01000 1 UCB1000L 130kA 1000A UCB1000L 3PESB0000Y 01000 1 UCB1000S 4PESB0000Y 01000 1 Specification Bus bar type terminal connection, No option, 50Hz Bus bar type terminal connection, No option, 60Hz Category MCCB /M3 �Electronic - LTD, STD, INST, GFT trip & PTA Model / Breaking capacity at AC380/415V 표준품 주문코드 Rated current UCB1000S 100kA 1000A UCB1000S 3PGSB0000X 01000 1 UCB1000S 4PGSB0000X 01000 1 UCB1000L 130kA 1000A UCB1000L 3PGSB0000X 01000 1 UCB1000L 4PGSB0000X 01000 1 UCB1000S 100kA 1000A UCB1000S 3PGSB0000Y 01000 1 UCB1000S 4PGSB0000Y 01000 1 UCB1000L 130kA 1000A UCB1000L 3PGSB0000Y 01000 1 UCB1000L 4PGSB0000Y 01000 1 3 pole Code 4 pole Unit (EA) Code Unit (EA) Specification Bus bar type terminal connection, No option, 50Hz Bus bar type terminal connection, No option, 60Hz Category MCCB /M3 Molded Case Circuit Breaker_ 87 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UCB type / 1250AF | �UCB1250S 100kA �UCB1250L 130kA UCB1250S UCB1250L Number of poles (P) 3, 4 Degree of protection (without terminal bus bar) IP20 Utilization category A Suitability of isolation ○ Protection overload, inst., short-circuit Rated current (A) 630-1,250 Rated insulation voltage [Ui] (V) AC750 Rated operational voltage [Ue] (V) AC690 Rating Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit breaking capacity Ultimate [Icu] (kA r.m.s.) IEC 60947-2 K 60947-2 8 AC600/660V, 50-60Hz 40 60 AC480/500V, 50-60Hz 75 100 AC440/460V, 50-60Hz 75 100 AC380/415V, 50-60Hz 100 130 AC220/240V, 50-60Hz 100 150 Service [Ics] % of [Icu] Trip mechanism Electronic & Protection characteristics Mounting LTD (0.5-1) ×In (15 setting) Short time delay STD (2-4-6-8-10)×Ir Instantaneous INST (3-6-8-10-11)×In Ground fault trip GFT (0.2-0.3-0.4)×In Pre-trip alarm PTA 0.9×In I2T lamp ○ Pick-up LED ○ ○ ○ Bus bar Mechanical operation 10,000 Electrical operation (times) 3,000 a Dimensions (mm) Long time delay Direct mounting by screw Terminal connection Durability (times) 50 1) d c 3/4P b a Width 210/280 b Height 370 c Depth 110/200 d Weight (kg, breaker only) 3/4P 159/249 13.5/17.5 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) (0.5-1): (0.63-0.8-1)x(0.8-0.85-0.9-0.95-1) 88 25.5/33.5 MCCB ■ Accessories �Signal 1ab, Right-hand-side 2ab, Right-hand-side 3ab, Right-hand-side Auxiliary switch AUX 80NE R1 Trip alarm switch Shunt trip AUX 80NE R2 AUX 80NE R3 1ab, Right-hand-side ALT 80NE R1 DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V SHT 120NE A SHT 120NE C SHT 120NE F SHT 120NE H SHT 120NE B SHT 120NE D 1) Under voltage trip 2) DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V UVT 120NE J UVT 120NE L UVT 120NE N UVT 120NE P UVT 120NE Q UVT 120NE R ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Operating Motor operator 1) DC24V AC/DC110V AC/DC220V MOT 80NE DC24 MOT 80NE ADC110 MOT 80NE ADC220 Extension handle 2) THA 80NE ※ 1) Motor operator is not recommended for marine application. 2) Supplied as standard component �Terminal Interpole barrier 1) 4EA/SET TQQ 80NE ※1) Supplied as standard component Required quantity for both line and load side of breaker: 3 pole 4EA, 4 pole 6EA ■ Standard order code and unit �Electronic - LTD, STD, INST trip Model / Breaking capacity at AC380/415V 표준품 주문코드 Rated current UCB1250S 100kA 1250A UCB1250S 3PESB0000X 01250 1 UCB1250S 4PESB0000X 01250 3 pole Code 4 pole Unit (EA) Code Unit (EA) 1 UCB1250L 130kA 1250A UCB1250L 3PESB0000X 01250 1 UCB1250L 4PESB0000X 01250 1 UCB1250S 100kA 1250A UCB1250S 3PESB0000Y 01250 1 UCB1250S 4PESB0000Y 01250 1 UCB1250L 130kA 1250A UCB1250L 3PESB0000Y 01250 1 UCB1250L 4PESB0000Y 01250 1 Specification Bus bar type terminal connection, No option, 50Hz Bus bar type terminal connection, No option, 60Hz Category MCCB /M3 �Electronic - LTD, STD, INST, GFT trip & PTA Model / Breaking capacity at AC380/415V 표준품 주문코드 Rated current UCB1250S 100kA 1250A UCB1250S 3PGSB0000X 01250 1 UCB1250S 4PGSB0000X 01250 1 3 pole Code 4 pole Unit (EA) Code Unit (EA) UCB1250L 130kA 1250A UCB1250L 3PGSB0000X 01250 1 UCB1250L 4PGSB0000X 01250 1 UCB1250S 100kA 1250A UCB1250S 3PGSB0000Y 01250 1 UCB1250S 4PGSB0000Y 01250 1 UCB1250L 130kA 1250A UCB1250L 3PGSB0000Y 01250 1 UCB1250L 4PGSB0000Y 01250 1 Specification Bus bar type terminal connection, No option, 50Hz Bus bar type terminal connection, No option, 60Hz Category MCCB /M3 Molded Case Circuit Breaker_ 89 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UCB type / 1600AF | �UCB1600S 65kA UCB1600S Number of poles (P) 3 Degree of protection (without terminal bus bar) IP20 Utilization category A Suitability of isolation ○ Protection overload, inst., short-circuit Rated current (A) 640-1,600 Rated insulation voltage [Ui] (V) AC750 Rated operational voltage [Ue] (V) AC690 Rating Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit breaking capacity Ultimate [Icu] (kA r.m.s.) IEC 60947-2 K 60947-2 8 AC600/660V, 50-60Hz 25 AC480/500V, 50-60Hz 35 AC440/460V, 50-60Hz 45 AC380/415V, 50-60Hz 65 AC220/240V, 50-60Hz 100 Service [Ics] % of [Icu] Trip mechanism Electronic & Protection characteristics Mounting LTD (0.4-1) ×In (8 setting) Instantaneous INST (2-3-4-5-6-7-8-10)×In ○ Pick-up LED ○ ○ Bus bar Mechanical operation 10,000 Electrical operation 3,000 a Dimensions (mm) Long time delay Direct mounting by screw Terminal connection Durability (times) 50 1) d c b 3/4P a Width 210 b Height 371 c Depth 151 d Weight (kg, breaker only) 3/4P 215 27 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) (0.4-1): (0.4-0.5-0.6-0.7-0.8-0.9-0.95-1) 90 MCCB ■ Accessories �Signal Auxiliary switch Shunt trip 1) Under voltage trip 2) 1ab, Right-hand-side 2ab, Right-hand-side AUX 160NE R1 AUX 160NE R2 DC24V DC100-110V AC100-120V AC200-230V AC380V SHT 160NE A SHT 160NE C SHT 160NE F SHT 160NE H SHT 160NE B DC24V DC100-110V AC100-120V AC200-230V AC380V - - - UVT 160NE P UVT 160NE Q ※1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Operating Operating handle Extended type Motor operator 1) AC220V TFH 160NE MOT 160NE AC220 THA 160NE Extension handle 2) ※ 1) Motor operator is not recommended for marine application. 2) Supplied as standard component �Terminal Terminal cover 1) Interpole barrier 2) TCF 160NE 3 4EA/SET TQQ 160NE ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component ■ Standard order code and unit �Electronic - LTD, INST trip Model / Breaking capacity at AC380/415V UCB1600S 65kA 3 pole Rated current Code Unit (EA) 1600A UCB1600S 3PESB0000C 01600 1 Specification Category Bus bar type terminal connection, No option, 50/60Hz MCCB/M3 Molded Case Circuit Breaker_ 91 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UPB type / 125AF | �UPB100S 85kA �UPB100H 100kA �UPB100L 130kA �UPB100X 150kA UPB100S Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Thermal magnetic type Rated current (A) Electronic type Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) AC660/690V, 50-60Hz Rated AC480/500V, 50-60Hz short-circuit AC440/460V, 50-60Hz Ultimate breaking [Icu] AC380/415V, 50-60Hz capacity (kA r.m.s.) AC220/240V, 50-60Hz DC250V IEC 60947-2 DC125V K 60947-2 Service [Ics] % of [Icu] Fixed thermal, Thermal Fixed instantaneous INST magnetic Adjustable thermal, LTD Trip Fixed instantaneous INST mechanism Long time delay LTD & Protection characteristics Short time delay STD Electronic Instantaneous INST Pre-trip alarm PTA Pick-up LED Direct mounting by screw Mounting Both line & load side for Plug-in Switchboard Line side only Screw Terminal connection Bus bar Mechanical operation Durability (times) Electrical operation d a a Width c Dimensions b Height 3/4P b (mm) c Depth d Weight (kg, breaker only) 3/4P 10 50 65 85 100 501) 651) UPB100H UPB100L 3, 4 IP20 A ○ overload, inst., short-circuit 15,16,20,25,30,32,40,50,63,80,100,125 50-125 AC750 AC690 DC500 1) 8 10 25 65 85 85 100 100 130 130 150 65 1) 85 1) 100 1) 100 1) 100 ○ 10×In (0.8-0.9-1)×In 10×In 50,55,63,70,80,90,100,115,125 (NON-2-3-4-5-6-7-8-9-10)×Ir 11×In 0.9×Ir ○ ○ ○2) ○2) ○ ○ 25,000 10,000 105/140 165 86.5 112 1.8/2.2 UPB100X 25 85 150 150 200 1001) 1) 100 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) DC is not applicable for electronic breaker. 2) Available for 3P breaker ■ Accessories �Signal Auxiliary switch Trip alarm switch Shunt trip 1) Under voltage trip 2) 1ab, Right-hand-side AUX 12UP R1 1ab, Left-hand-side ALT 12UP L1 DC24V SHT 12UP A DC24V �UVT 12UP J DC100-110V SHT 12UP C DC100-110V �UVT 12UP L AC100-120V SHT 12UP F AC100-120V �UVT 12UP N ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. 92 AC200-230V SHT 12UP H AC200-230V �UVT 12UP P AC380-415V SHT 12UP B AC380-415V �UVT 12UP Q AC440-480V SHT 12UP D AC440-480V �UVT 12UP R MCCB �Operating Upper TFG 12UPS U4 TFG 12UPL U4 Power supply direction S type Operating Surface L type 1) handle S type Extended L type Right TFG 12UPS R4 TFH 12UPS TFH 12UPL AC/DC110V MOT 12UP ADC110 DC24V MOT 12UP DC24 3 pole MIF 12UP 3 Motor operator 2) Mechanical interlock Left TFG 12UPS L4 TFG 12UPL L4 AC/DC220V MOT 12UP ADC220 4 pole MIF 12UP 4 PLD 12UP Padlock plate ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting Plug-in 1) Structure Mounting base Connection 4C contact block 2) 12C contact For both line & load side TDM 12NEP CBM 26NE 6 CBM 26NE 12 For line side only TDM 12NEF - ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal Terminal bus bar Cage terminal block Terminal cover 1) Interpole barrier 2) 3 pole (6EA/SET) 4 pole (8EA/SET) 3EA/SET 4EA/SET 3 pole 4 pole 4EA/SET TBB 12NE 3 TBB 12NE 4 CTB 12UP 3S CTB 12UP 4S TCF 12UP 3 TCF 12UP 4 TQQ 12NE ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 3 pole 4EA, 4 pole 6EA ■ Standard order code and unit �Electronic - LTD, STD, INST trip Model / Breaking capacity at AC380/415V UPB100S 85kA UPB100H 100kA UPB100L 130kA UPB100X 150kA UPB100S 85kA UPB100H 100kA UPB100L 130kA UPB100X 150kA Rated current 125A 125A 125A 125A 125A 125A 125A 125A 3 pole 4 pole Code Unit (EA) Code Unit (EA) UPB100S 3PESS0000X 00125 UPB100H 3PESS0000X 00125 UPB100L 3PESS0000X 00125 UPB100X 3PESS0000X 00125 UPB100S 3PESS0000Y 00125 UPB100H 3PESS0000Y 00125 UPB100L 3PESS0000Y 00125 UPB100X 3PESS0000Y 00125 8 8 8 8 8 8 8 8 UPB100S 4PESS0000X 00125 UPB100H 4PESS0000X 00125 UPB100L 4PESS0000X 00125 UPB100X 4PESS0000X 00125 UPB100S 4PESS0000Y 00125 UPB100H 4PESS0000Y 00125 UPB100L 4PESS0000Y 00125 UPB100X 4PESS0000Y 00125 6 6 6 6 6 6 6 6 Specification Category Screw type terminal connection, No option, 50Hz MCCB/M3 Screw type terminal connection, No option, 60Hz �Electronic - LTD, STD, INST, GFT trip & PTA Model / Breaking capacity at AC380/415V UPB100S 85kA UPB100H 100kA UPB100L 130kA UPB100X 150kA UPB100S 85kA UPB100H 100kA UPB100L 130kA UPB100X 150kA Rated current 125A 125A 125A 125A 125A 125A 125A 125A 3 pole Code UPB100S 3PGSS0000X 00125 UPB100H 3PGSS0000X 00125 UPB100L 3PGSS0000X 00125 UPB100X 3PGSS0000X 00125 UPB100S 3PGSS0000Y 00125 UPB100H 3PGSS0000Y 00125 UPB100L 3PGSS0000Y 00125 UPB100X 3PGSS0000Y 00125 4 pole Unit (EA) Code Unit (EA) 8 8 8 8 8 8 8 8 UPB100S 4PGSS0000X 00125 UPB100H 4PGSS0000X 00125 UPB100L 4PGSS0000X 00125 UPB100X 4PGSS0000X 00125 UPB100S 4PGSS0000Y 00125 UPB100H 4PGSS0000Y 00125 UPB100L 4PGSS0000Y 00125 UPB100X 4PGSS0000Y 00125 6 6 6 6 6 6 6 6 Specification Category Screw type terminal connection, No option, 50Hz Screw type terminal connection, No option, 60Hz MCCB/M3 Molded Case Circuit Breaker_ 93 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V 94 Rated current 3 pole Code Unit (EA) 4 pole Code Unit (EA) 15A UPB100S 3PT4S0000C 00015 8 UPB100S 4PT4S0000C 00015 6 16A UPB100S 3PT4S0000C 00016 8 UPB100S 4PT4S0000C 00016 6 20A UPB100S 3PT4S0000C 00020 8 UPB100S 4PT4S0000C 00020 6 25A UPB100S 3PT4S0000C 00025 8 UPB100S 4PT4S0000C 00025 6 30A UPB100S 3PT4S0000C 00030 8 UPB100S 4PT4S0000C 00030 6 UPB100S 32A UPB100S 3PT4S0000C 00032 8 UPB100S 4PT4S0000C 00032 6 85kA 40A UPB100S 3PT4S0000C 00040 8 UPB100S 4PT4S0000C 00040 6 50A UPB100S 3PT4S0000C 00050 8 UPB100S 4PT4S0000C 00050 6 63A UPB100S 3PT4S0000C 00063 8 UPB100S 4PT4S0000C 00063 6 80A UPB100S 3PT4S0000C 00080 8 UPB100S 4PT4S0000C 00080 6 100A UPB100S 3PT4S0000C 00100 8 UPB100S 4PT4S0000C 00100 6 125A UPB100S 3PT4S0000C 00125 8 UPB100S 4PT4S0000C 00125 6 15A UPB100H 3PT4S0000C 00015 8 UPB100H 4PT4S0000C 00015 6 16A UPB100H 3PT4S0000C 00016 8 UPB100H 4PT4S0000C 00016 6 20A UPB100H 3PT4S0000C 00020 8 UPB100H 4PT4S0000C 00020 6 25A UPB100H 3PT4S0000C 00025 8 UPB100H 4PT4S0000C 00025 6 30A UPB100H 3PT4S0000C 00030 8 UPB100H 4PT4S0000C 00030 6 UPB100H 32A UPB100H 3PT4S0000C 00032 8 UPB100H 4PT4S0000C 00032 6 100kA 40A UPB100H 3PT4S0000C 00040 8 UPB100H 4PT4S0000C 00040 6 50A UPB100H 3PT4S0000C 00050 8 UPB100H 4PT4S0000C 00050 6 63A UPB100H 3PT4S0000C 00063 8 UPB100H 4PT4S0000C 00063 6 80A UPB100H 3PT4S0000C 00080 8 UPB100H 4PT4S0000C 00080 6 100A UPB100H 3PT4S0000C 00100 8 UPB100H 4PT4S0000C 00100 6 125A UPB100H 3PT4S0000C 00125 8 UPB100H 4PT4S0000C 00125 6 15A UPB100L 3PT4S0000C 00015 8 UPB100L 4PT4S0000C 00015 6 16A UPB100L 3PT4S0000C 00016 8 UPB100L 4PT4S0000C 00016 6 20A UPB100L 3PT4S0000C 00020 8 UPB100L 4PT4S0000C 00020 6 25A UPB100L 3PT4S0000C 00025 8 UPB100L 4PT4S0000C 00025 6 30A UPB100L 3PT4S0000C 00030 8 UPB100L 4PT4S0000C 00030 6 UPB100L 32A UPB100L 3PT4S0000C 00032 8 UPB100L 4PT4S0000C 00032 6 130kA 40A UPB100L 3PT4S0000C 00040 8 UPB100L 4PT4S0000C 00040 6 50A UPB100L 3PT4S0000C 00050 8 UPB100L 4PT4S0000C 00050 6 63A UPB100L 3PT4S0000C 00063 8 UPB100L 4PT4S0000C 00063 6 80A UPB100L 3PT4S0000C 00080 8 UPB100L 4PT4S0000C 00080 6 100A UPB100L 3PT4S0000C 00100 8 UPB100L 4PT4S0000C 00100 6 125A UPB100L 3PT4S0000C 00125 8 UPB100L 4PT4S0000C 00125 6 15A UPB100X 3PT4S0000C 00015 8 UPB100X 4PT4S0000C 00015 6 16A UPB100X 3PT4S0000C 00016 8 UPB100X 4PT4S0000C 00016 6 20A UPB100X 3PT4S0000C 00020 8 UPB100X 4PT4S0000C 00020 6 25A UPB100X 3PT4S0000C 00025 8 UPB100X 4PT4S0000C 00025 6 30A UPB100X 3PT4S0000C 00030 8 UPB100X 4PT4S0000C 00030 6 UPB100X 32A UPB100X 3PT4S0000C 00032 8 UPB100X 4PT4S0000C 00032 6 150kA 40A UPB100X 3PT4S0000C 00040 8 UPB100X 4PT4S0000C 00040 6 50A UPB100X 3PT4S0000C 00050 8 UPB100X 4PT4S0000C 00050 6 63A UPB100X 3PT4S0000C 00063 8 UPB100X 4PT4S0000C 00063 6 80A UPB100X 3PT4S0000C 00080 8 UPB100X 4PT4S0000C 00080 6 100A UPB100X 3PT4S0000C 00100 8 UPB100X 4PT4S0000C 00100 6 125A UPB100X 3PT4S0000C 00125 8 UPB100X 4PT4S0000C 00125 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 MCCB 50℃ Model / Breaking capacity at AC380/415V Rated current 3 pole Code Unit (EA) 4 pole Code Unit (EA) 15A UPB100S 3PT5S0000C 00015 8 UPB100S 4PT5S0000C 00015 6 16A UPB100S 3PT5S0000C 00016 8 UPB100S 4PT5S0000C 00016 6 20A UPB100S 3PT5S0000C 00020 8 UPB100S 4PT5S0000C 00020 6 25A UPB100S 3PT5S0000C 00025 8 UPB100S 4PT5S0000C 00025 6 30A UPB100S 3PT5S0000C 00030 8 UPB100S 4PT5S0000C 00030 6 UPB100S 32A UPB100S 3PT5S0000C 00032 8 UPB100S 4PT5S0000C 00032 6 85kA 40A UPB100S 3PT5S0000C 00040 8 UPB100S 4PT5S0000C 00040 6 50A UPB100S 3PT5S0000C 00050 8 UPB100S 4PT5S0000C 00050 6 63A UPB100S 3PT5S0000C 00063 8 UPB100S 4PT5S0000C 00063 6 80A UPB100S 3PT5S0000C 00080 8 UPB100S 4PT5S0000C 00080 6 100A UPB100S 3PT5S0000C 00100 8 UPB100S 4PT5S0000C 00100 6 125A UPB100S 3PT5S0000C 00125 8 UPB100S 4PT5S0000C 00125 6 15A UPB100H 3PT5S0000C 00015 8 UPB100H 4PT5S0000C 00015 6 16A UPB100H 3PT5S0000C 00016 8 UPB100H 4PT5S0000C 00016 6 20A UPB100H 3PT5S0000C 00020 8 UPB100H 4PT5S0000C 00020 6 25A UPB100H 3PT5S0000C 00025 8 UPB100H 4PT5S0000C 00025 6 30A UPB100H 3PT5S0000C 00030 8 UPB100H 4PT5S0000C 00030 6 UPB100H 32A UPB100H 3PT5S0000C 00032 8 UPB100H 4PT5S0000C 00032 6 100kA 40A UPB100H 3PT5S0000C 00040 8 UPB100H 4PT5S0000C 00040 6 50A UPB100H 3PT5S0000C 00050 8 UPB100H 4PT5S0000C 00050 6 63A UPB100H 3PT5S0000C 00063 8 UPB100H 4PT5S0000C 00063 6 80A UPB100H 3PT5S0000C 00080 8 UPB100H 4PT5S0000C 00080 6 100A UPB100H 3PT5S0000C 00100 8 UPB100H 4PT5S0000C 00100 6 125A UPB100H 3PT5S0000C 00125 8 UPB100H 4PT5S0000C 00125 6 15A UPB100L 3PT5S0000C 00015 8 UPB100L 4PT5S0000C 00015 6 16A UPB100L 3PT5S0000C 00016 8 UPB100L 4PT5S0000C 00016 6 20A UPB100L 3PT5S0000C 00020 8 UPB100L 4PT5S0000C 00020 6 25A UPB100L 3PT5S0000C 00025 8 UPB100L 4PT5S0000C 00025 6 30A UPB100L 3PT5S0000C 00030 8 UPB100L 4PT5S0000C 00030 6 UPB100L 32A UPB100L 3PT5S0000C 00032 8 UPB100L 4PT5S0000C 00032 6 130kA 40A UPB100L 3PT5S0000C 00040 8 UPB100L 4PT5S0000C 00040 6 50A UPB100L 3PT5S0000C 00050 8 UPB100L 4PT5S0000C 00050 6 63A UPB100L 3PT5S0000C 00063 8 UPB100L 4PT5S0000C 00063 6 80A UPB100L 3PT5S0000C 00080 8 UPB100L 4PT5S0000C 00080 6 100A UPB100L 3PT5S0000C 00100 8 UPB100L 4PT5S0000C 00100 6 125A UPB100L 3PT5S0000C 00125 8 UPB100L 4PT5S0000C 00125 6 15A UPB100X 3PT5S0000C 00015 8 UPB100X 4PT5S0000C 00015 6 16A UPB100X 3PT5S0000C 00016 8 UPB100X 4PT5S0000C 00016 6 20A UPB100X 3PT5S0000C 00020 8 UPB100X 4PT5S0000C 00020 6 25A UPB100X 3PT5S0000C 00025 8 UPB100X 4PT5S0000C 00025 6 30A UPB100X 3PT5S0000C 00030 8 UPB100X 4PT5S0000C 00030 6 UPB100X 32A UPB100X 3PT5S0000C 00032 8 UPB100X 4PT5S0000C 00032 6 150kA 40A UPB100X 3PT5S0000C 00040 8 UPB100X 4PT5S0000C 00040 6 50A UPB100X 3PT5S0000C 00050 8 UPB100X 4PT5S0000C 00050 6 63A UPB100X 3PT5S0000C 00063 8 UPB100X 4PT5S0000C 00063 6 80A UPB100X 3PT5S0000C 00080 8 UPB100X 4PT5S0000C 00080 6 100A UPB100X 3PT5S0000C 00100 8 UPB100X 4PT5S0000C 00100 6 125A UPB100X 3PT5S0000C 00125 8 UPB100X 4PT5S0000C 00125 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 Molded Case Circuit Breaker_ 95 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit �Adjustable thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V 96 Rated current 3 pole Code Unit (EA) 4 pole Code Unit (EA) 15A UPB100S 3PT4S0000C 00015F 8 UPB100S 4PT4S0000C 00015F 6 16A UPB100S 3PT4S0000C 00016F 8 UPB100S 4PT4S0000C 00016F 6 20A UPB100S 3PT4S0000C 00020F 8 UPB100S 4PT4S0000C 00020F 6 25A UPB100S 3PT4S0000C 00025F 8 UPB100S 4PT4S0000C 00025F 6 30A UPB100S 3PT4S0000C 00030F 8 UPB100S 4PT4S0000C 00030F 6 UPB100S 32A UPB100S 3PT4S0000C 00032F 8 UPB100S 4PT4S0000C 00032F 6 85kA 40A UPB100S 3PT4S0000C 00040F 8 UPB100S 4PT4S0000C 00040F 6 50A UPB100S 3PT4S0000C 00050F 8 UPB100S 4PT4S0000C 00050F 6 63A UPB100S 3PT4S0000C 00063F 8 UPB100S 4PT4S0000C 00063F 6 80A UPB100S 3PT4S0000C 00080F 8 UPB100S 4PT4S0000C 00080F 6 100A UPB100S 3PT4S0000C 00100F 8 UPB100S 4PT4S0000C 00100F 6 125A UPB100S 3PT4S0000C 00125F 8 UPB100S 4PT4S0000C 00125F 6 15A UPB100H 3PT4S0000C 00015F 8 UPB100H 4PT4S0000C 00015F 6 16A UPB100H 3PT4S0000C 00016F 8 UPB100H 4PT4S0000C 00016F 6 20A UPB100H 3PT4S0000C 00020F 8 UPB100H 4PT4S0000C 00020F 6 25A UPB100H 3PT4S0000C 00025F 8 UPB100H 4PT4S0000C 00025F 6 30A UPB100H 3PT4S0000C 00030F 8 UPB100H 4PT4S0000C 00030F 6 UPB100H 32A UPB100H 3PT4S0000C 00032F 8 UPB100H 4PT4S0000C 00032F 6 100kA 40A UPB100H 3PT4S0000C 00040F 8 UPB100H 4PT4S0000C 00040F 6 50A UPB100H 3PT4S0000C 00050F 8 UPB100H 4PT4S0000C 00050F 6 63A UPB100H 3PT4S0000C 00063F 8 UPB100H 4PT4S0000C 00063F 6 80A UPB100H 3PT4S0000C 00080F 8 UPB100H 4PT4S0000C 00080F 6 100A UPB100H 3PT4S0000C 00100F 8 UPB100H 4PT4S0000C 00100F 6 125A UPB100H 3PT4S0000C 00125F 8 UPB100H 4PT4S0000C 00125F 6 15A UPB100L 3PT4S0000C 00015F 8 UPB100L 4PT4S0000C 00015F 6 16A UPB100L 3PT4S0000C 00016F 8 UPB100L 4PT4S0000C 00016F 6 20A UPB100L 3PT4S0000C 00020F 8 UPB100L 4PT4S0000C 00020F 6 25A UPB100L 3PT4S0000C 00025F 8 UPB100L 4PT4S0000C 00025F 6 30A UPB100L 3PT4S0000C 00030F 8 UPB100L 4PT4S0000C 00030F 6 UPB100L 32A UPB100L 3PT4S0000C 00032F 8 UPB100L 4PT4S0000C 00032F 6 130kA 40A UPB100L 3PT4S0000C 00040F 8 UPB100L 4PT4S0000C 00040F 6 50A UPB100L 3PT4S0000C 00050F 8 UPB100L 4PT4S0000C 00050F 6 63A UPB100L 3PT4S0000C 00063F 8 UPB100L 4PT4S0000C 00063F 6 80A UPB100L 3PT4S0000C 00080F 8 UPB100L 4PT4S0000C 00080F 6 100A UPB100L 3PT4S0000C 00100F 8 UPB100L 4PT4S0000C 00100F 6 125A UPB100L 3PT4S0000C 00125F 8 UPB100L 4PT4S0000C 00125F 6 15A UPB100X 3PT4S0000C 00015F 8 UPB100X 4PT4S0000C 00015F 6 16A UPB100X 3PT4S0000C 00016F 8 UPB100X 4PT4S0000C 00016F 6 20A UPB100X 3PT4S0000C 00020F 8 UPB100X 4PT4S0000C 00020F 6 25A UPB100X 3PT4S0000C 00025F 8 UPB100X 4PT4S0000C 00025F 6 30A UPB100X 3PT4S0000C 00030F 8 UPB100X 4PT4S0000C 00030F 6 UPB100X 32A UPB100X 3PT4S0000C 00032F 8 UPB100X 4PT4S0000C 00032F 6 150kA 40A UPB100X 3PT4S0000C 00040F 8 UPB100X 4PT4S0000C 00040F 6 50A UPB100X 3PT4S0000C 00050F 8 UPB100X 4PT4S0000C 00050F 6 63A UPB100X 3PT4S0000C 00063F 8 UPB100X 4PT4S0000C 00063F 6 80A UPB100X 3PT4S0000C 00080F 8 UPB100X 4PT4S0000C 00080F 6 100A UPB100X 3PT4S0000C 00100F 8 UPB100X 4PT4S0000C 00100F 6 125A UPB100X 3PT4S0000C 00125F 8 UPB100X 4PT4S0000C 00125F 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 MCCB 50℃ Model / Breaking capacity at AC380/415V Rated current 3 pole Code Unit (EA) 4 pole Code Unit (EA) 15A UPB100S 3PT5S0000C 00015F 8 UPB100S 4PT5S0000C 00015F 6 16A UPB100S 3PT5S0000C 00016F 8 UPB100S 4PT5S0000C 00016F 6 20A UPB100S 3PT5S0000C 00020F 8 UPB100S 4PT5S0000C 00020F 6 25A UPB100S 3PT5S0000C 00025F 8 UPB100S 4PT5S0000C 00025F 6 30A UPB100S 3PT5S0000C 00030F 8 UPB100S 4PT5S0000C 00030F 6 UPB100S 32A UPB100S 3PT5S0000C 00032F 8 UPB100S 4PT5S0000C 00032F 6 85kA 40A UPB100S 3PT5S0000C 00040F 8 UPB100S 4PT5S0000C 00040F 6 50A UPB100S 3PT5S0000C 00050F 8 UPB100S 4PT5S0000C 00050F 6 63A UPB100S 3PT5S0000C 00063F 8 UPB100S 4PT5S0000C 00063F 6 80A UPB100S 3PT5S0000C 00080F 8 UPB100S 4PT5S0000C 00080F 6 100A UPB100S 3PT5S0000C 00100F 8 UPB100S 4PT5S0000C 00100F 6 125A UPB100S 3PT5S0000C 00125F 8 UPB100S 4PT5S0000C 00125F 6 15A UPB100H 3PT5S0000C 00015F 8 UPB100H 4PT5S0000C 00015F 6 16A UPB100H 3PT5S0000C 00016F 8 UPB100H 4PT5S0000C 00016F 6 20A UPB100H 3PT5S0000C 00020F 8 UPB100H 4PT5S0000C 00020F 6 25A UPB100H 3PT5S0000C 00025F 8 UPB100H 4PT5S0000C 00025F 6 30A UPB100H 3PT5S0000C 00030F 8 UPB100H 4PT5S0000C 00030F 6 UPB100H 32A UPB100H 3PT5S0000C 00032F 8 UPB100H 4PT5S0000C 00032F 6 100kA 40A UPB100H 3PT5S0000C 00040F 8 UPB100H 4PT5S0000C 00040F 6 50A UPB100H 3PT5S0000C 00050F 8 UPB100H 4PT5S0000C 00050F 6 63A UPB100H 3PT5S0000C 00063F 8 UPB100H 4PT5S0000C 00063F 6 80A UPB100H 3PT5S0000C 00080F 8 UPB100H 4PT5S0000C 00080F 6 100A UPB100H 3PT5S0000C 00100F 8 UPB100H 4PT5S0000C 00100F 6 125A UPB100H 3PT5S0000C 00125F 8 UPB100H 4PT5S0000C 00125F 6 15A UPB100L 3PT5S0000C 00015F 8 UPB100L 4PT5S0000C 00015F 6 16A UPB100L 3PT5S0000C 00016F 8 UPB100L 4PT5S0000C 00016F 6 20A UPB100L 3PT5S0000C 00020F 8 UPB100L 4PT5S0000C 00020F 6 25A UPB100L 3PT5S0000C 00025F 8 UPB100L 4PT5S0000C 00025F 6 30A UPB100L 3PT5S0000C 00030F 8 UPB100L 4PT5S0000C 00030F 6 UPB100L 32A UPB100L 3PT5S0000C 00032F 8 UPB100L 4PT5S0000C 00032F 6 130kA 40A UPB100L 3PT5S0000C 00040F 8 UPB100L 4PT5S0000C 00040F 6 50A UPB100L 3PT5S0000C 00050F 8 UPB100L 4PT5S0000C 00050F 6 63A UPB100L 3PT5S0000C 00063F 8 UPB100L 4PT5S0000C 00063F 6 80A UPB100L 3PT5S0000C 00080F 8 UPB100L 4PT5S0000C 00080F 6 100A UPB100L 3PT5S0000C 00100F 8 UPB100L 4PT5S0000C 00100F 6 125A UPB100L 3PT5S0000C 00125F 8 UPB100L 4PT5S0000C 00125F 6 15A UPB100X 3PT5S0000C 00015F 8 UPB100X 4PT5S0000C 00015F 6 16A UPB100X 3PT5S0000C 00016F 8 UPB100X 4PT5S0000C 00016F 6 20A UPB100X 3PT5S0000C 00020F 8 UPB100X 4PT5S0000C 00020F 6 25A UPB100X 3PT5S0000C 00025F 8 UPB100X 4PT5S0000C 00025F 6 30A UPB100X 3PT5S0000C 00030F 8 UPB100X 4PT5S0000C 00030F 6 UPB100X 32A UPB100X 3PT5S0000C 00032F 8 UPB100X 4PT5S0000C 00032F 6 150kA 40A UPB100X 3PT5S0000C 00040F 8 UPB100X 4PT5S0000C 00040F 6 50A UPB100X 3PT5S0000C 00050F 8 UPB100X 4PT5S0000C 00050F 6 63A UPB100X 3PT5S0000C 00063F 8 UPB100X 4PT5S0000C 00063F 6 80A UPB100X 3PT5S0000C 00080F 8 UPB100X 4PT5S0000C 00080F 6 100A UPB100X 3PT5S0000C 00100F 8 UPB100X 4PT5S0000C 00100F 6 125A UPB100X 3PT5S0000C 00125F 8 UPB100X 4PT5S0000C 00125F 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 Molded Case Circuit Breaker_ 97 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UPB type / 160AF | �UPB160S 85kA �UPB160H 100kA �UPB160L 130kA �UPB160X 150kA UPB160S UPB160L 3, 4 IP20 A ○ overload, inst., short-circuit 100,125,160 63-160 AC750 AC690 DC500 1) 8 10 25 65 85 85 100 100 130 130 150 65 1) 85 1) 100 1) 100 1) 100 ○ 10×In (0.8-0.9-1)×In 10×In (0.8-0.9-1)×In (5-6-7-8-9-10)×In 63,70,80,90,100,110,125,140,160 (NON-2-3-4-5-6-7-8-9-10)×Ir 11×In 0.9×Ir ○ ○ ○2) ○2) ○ ○ 25,000 10,000 105/140 165 86.5 112 2.0/2.4 Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Thermal magnetic type Rated current (A) Electronic type Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) AC660/690V, 50-60Hz Rated AC480/500V, 50-60Hz short-circuit AC440/460V, 50-60Hz Ultimate breaking AC380/415V, 50-60Hz [Icu] capacity (kA r.m.s.) AC220/240V, 50-60Hz DC250V IEC 60947-2 DC125V K 60947-2 Service [Ics] % of [Icu] Fixed thermal, Fixed instantaneous INST Thermal Adjustable thermal, LTD magnetic Fixed instantaneous INST Adjustable thermal, LTD Trip Adjustable instantaneous INST mechanism & Protection Long time delay LTD characteristics Short time delay STD Electronic Instantaneous INST Pre-trip alarm PTA Pick-up LED Direct mounting by screw Mounting Both line & load side for Plug-in Switchboard Line side only Screw Terminal connection Bus bar Durability Mechanical operation (times) Electrical operation d a a Width c Dimensions b Height 3/4P b (mm) c Depth d Weight (kg, breaker only) 3/4P UPB160H 10 50 65 85 100 50 1) 65 1) UPB160X 25 85 150 150 200 100 1) 100 1) ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) DC is not applicable for electronic breaker. 2) Available for 3P breaker ■ Accessories �Signal Auxiliary switch Trip alarm switch Shunt trip 1) Under voltage trip 2) 98 1ab, Right-hand-side AUX 12UP R1 1ab, Left-hand-side ALT 12UP L1 DC24V SHT 12UP A DC24V �UVT 12UP J DC100-110V SHT 12UP C DC100-110V �UVT 12UP L AC100-120V SHT 12UP F AC100-120V �UVT 12UP N ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. AC200-230V SHT 12UP H AC200-230V �UVT 12UP P AC380-415V SHT 12UP B AC380-415V �UVT 12UP Q AC440-480V SHT 12UP D AC440-480V �UVT 12UP R MCCB �Operating Upper TFG 12UPS U4 TFG 12UPL U4 Power supply direction S type Operating Surface L type 1) handle S type Extended L type Right TFG 12UPS R4 TFH 12UPS TFH 12UPL AC/DC110V MOT 12UP ADC110 DC24V MOT 12UP DC24 3 pole MIF 12UP 3 Motor operator 2) Mechanical interlock Left TFG 12UPS L4 TFG 12UPL L4 AC/DC220V MOT 12UP ADC220 4 pole MIF 12UP 4 PLD 12UP Padlock plate ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting Plug-in 1) Structure Mounting base Connection 6C contact block 2) 12C contact For both line & load side TDM 12NEP CBM 26NE 6 CBM 26NE 12 For line side only TDM 12NEF - ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal Terminal bus bar Cage terminal block Terminal cover 1) Interpole barrier 2) 3 pole (6EA/SET) 4 pole (8EA/SET) 3EA/SET 4EA/SET 3 pole 4 pole 4EA/SET TBB 12NE 3 TBB 12NE 4 CTB 12UP 3S CTB 12UP 4S TCF 12UP 3 TCF 12UP 4 TQQ 12NE ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 3 pole 4EA, 4 pole 6EA ■ Standard order code and unit �Electronic - LTD, STD, INST trip Model / Breaking capacity at AC380/415V UPB160S 85kA UPB160H 100kA UPB160L 130kA UPB160X 150kA UPB160S 85kA UPB160H 100kA UPB160L 130kA UPB160X 150kA Rated current 160A 160A 160A 160A 160A 160A 160A 160A 3 pole Code UPB160S 3PESS0000X 00160 UPB160H 3PESS0000X 00160 UPB160L 3PESS0000X 00160 UPB160X 3PESS0000X 00160 UPB160S 3PESS0000Y 00160 UPB160H 3PESS0000Y 00160 UPB160L 3PESS0000Y 00160 UPB160X 3PESS0000Y 00160 4 pole Unit (EA) Code Unit (EA) 8 8 8 8 8 8 8 8 UPB160S 4PESS0000X 00160 UPB160H 4PESS0000X 00160 UPB160L 4PESS0000X 00160 UPB160X 4PESS0000X 00160 UPB160S 4PESS0000Y 00160 UPB160H 4PESS0000Y 00160 UPB160L 4PESS0000Y 00160 UPB160X 4PESS0000Y 00160 6 6 6 6 6 6 6 6 Specification Category Screw type terminal connection, No option, 50Hz MCCB/M3 Screw type terminal connection, No option, 60Hz �Electronic - LTD, STD, INST, GFT trip & PTA Model / Breaking capacity at AC380/415V UPB160S 85kA UPB160H 100kA UPB160L 130kA UPB160X 150kA UPB160S 85kA UPB160H 100kA UPB160L 130kA UPB160X 150kA Rated current 160A 160A 160A 160A 160A 160A 160A 160A 3 pole Code UPB160S 3PGSS0000X 00160 UPB160H 3PGSS0000X 00160 UPB160L 3PGSS0000X 00160 UPB160X 3PGSS0000X 00160 UPB160S 3PGSS0000Y 00160 UPB160H 3PGSS0000Y 00160 UPB160L 3PGSS0000Y 00160 UPB160X 3PGSS0000Y 00160 4 pole Unit (EA) Code Unit (EA) 8 8 8 8 8 8 8 8 UPB160S 4PGSS0000X 00160 UPB160H 4PGSS0000X 00160 UPB160L 4PGSS0000X 00160 UPB160X 4PGSS0000X 00160 UPB160S 4PGSS0000Y 00160 UPB160H 4PGSS0000Y 00160 UPB160L 4PGSS0000Y 00160 UPB160X 4PGSS0000Y 00160 6 6 6 6 6 6 6 6 Specification Category Screw type terminal connection, No option, 50Hz Screw type terminal connection, No option, 60Hz MCCB/M3 Molded Case Circuit Breaker_ 99 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V Rated current 3 pole Code 4 pole Unit (EA) Code Unit (EA) 100A UPB160S 3PT4S0000C 00100 8 UPB160S 4PT4S0000C 00100 6 125A UPB160S 3PT4S0000C 00125 8 UPB160S 4PT4S0000C 00125 6 160A UPB160S 3PT4S0000C 00160 8 UPB160S 4PT4S0000C 00160 6 100A UPB160H 3PT4S0000C 00100 8 UPB160H 4PT4S0000C 00100 6 125A UPB160H 3PT4S0000C 00125 8 UPB160H 4PT4S0000C 00125 6 160A UPB160H 3PT4S0000C 00160 8 UPB160H 4PT4S0000C 00160 6 100A UPB160L 3PT4S0000C 00100 8 UPB160L 4PT4S0000C 00100 6 125A UPB160L 3PT4S0000C 00125 8 UPB160L 4PT4S0000C 00125 6 160A UPB160L 3PT4S0000C 00160 8 UPB160L 4PT4S0000C 00160 6 100A UPB160X 3PT4S0000C 00100 8 UPB160X 4PT4S0000C 00100 6 UPB160X 150kA 125A UPB160X 3PT4S0000C 00125 8 UPB160X 4PT4S0000C 00125 6 160A UPB160X 3PT4S0000C 00160 8 UPB160X 4PT4S0000C 00160 6 Model / Breaking capacity at AC380/415V Rated current UPB160S 85kA UPB160H 100kA UPB160L 130kA Specification Screw type terminal connection, No option, 50/60Hz Category MCCB /M2 50℃ UPB160S 85kA UPB160H 100kA UPB160L 130kA UPB160X 150kA 3 pole Code 4 pole Unit (EA) Code Unit (EA) 100A UPB160S 3PT5S0000C 00100 8 UPB160S 4PT5S0000C 00100 6 125A UPB160S 3PT5S0000C 00125 8 UPB160S 4PT5S0000C 00125 6 160A UPB160S 3PT5S0000C 00160 8 UPB160S 4PT5S0000C 00160 6 100A UPB160H 3PT5S0000C 00100 8 UPB160H 4PT5S0000C 00100 6 125A UPB160H 3PT5S0000C 00125 8 UPB160H 4PT5S0000C 00125 6 160A UPB160H 3PT5S0000C 00160 8 UPB160H 4PT5S0000C 00160 6 100A UPB160L 3PT5S0000C 00100 8 UPB160L 4PT5S0000C 00100 6 125A UPB160L 3PT5S0000C 00125 8 UPB160L 4PT5S0000C 00125 6 160A UPB160L 3PT5S0000C 00160 8 UPB160L 4PT5S0000C 00160 6 100A UPB160X 3PT5S0000C 00100 8 UPB160X 4PT5S0000C 00100 6 125A UPB160X 3PT5S0000C 00125 8 UPB160X 4PT5S0000C 00125 6 160A UPB160X 3PT5S0000C 00160 8 UPB160X 4PT5S0000C 00160 6 Specification Screw type terminal connection, No option, 50/60Hz Category MCCB /M2 �Adjustable thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UPB160S 85kA UPB160H 100kA UPB160L 130kA UPB160X 150kA 100 3 pole 4 pole Rated current Code Unit (EA) 100A UPB160S 3PT4S0000C 00100F 8 UPB160S 4PT4S0000C 00100F 6 125A UPB160S 3PT4S0000C 00125F 8 UPB160S 4PT4S0000C 00125F 6 160A UPB160S 3PT4S0000C 00160F 8 UPB160S 4PT4S0000C 00160F 6 100A UPB160H 3PT4S0000C 00100F 8 UPB160H 4PT4S0000C 00100F 6 125A UPB160H 3PT4S0000C 00125F 8 UPB160H 4PT4S0000C 00125F 6 160A UPB160H 3PT4S0000C 00160F 8 UPB160H 4PT4S0000C 00160F 6 100A UPB160L 3PT4S0000C 00100F 8 UPB160L 4PT4S0000C 00100F 6 125A UPB160L 3PT4S0000C 00125F 8 UPB160L 4PT4S0000C 00125F 6 160A UPB160L 3PT4S0000C 00160F 8 UPB160L 4PT4S0000C 00160F 6 100A UPB160X 3PT4S0000C 00100F 8 UPB160X 4PT4S0000C 00100F 6 125A UPB160X 3PT4S0000C 00125F 8 UPB160X 4PT4S0000C 00125F 6 160A UPB160X 3PT4S0000C 00160F 8 UPB160X 4PT4S0000C 00160F 6 Code Unit (EA) Specification Screw type terminal connection, No option, 50/60Hz Category MCCB /M2 MCCB 50℃ Model / Breaking capacity at AC380/415V UPB160S 85kA UPB160H 100kA UPB160L 130kA UPB160X 150kA 3 pole 4 pole Rated current Code Unit (EA) 100A UPB160S 3PT5S0000C 00100F 8 UPB160S 4PT5S0000C 00100F 6 125A UPB160S 3PT5S0000C 00125F 8 UPB160S 4PT5S0000C 00125F 6 160A UPB160S 3PT5S0000C 00160F 8 UPB160S 4PT5S0000C 00160F 6 100A UPB160H 3PT5S0000C 00100F 8 UPB160H 4PT5S0000C 00100F 6 125A UPB160H 3PT5S0000C 00125F 8 UPB160H 4PT5S0000C 00125F 6 160A UPB160H 3PT5S0000C 00160F 8 UPB160H 4PT5S0000C 00160F 6 100A UPB160L 3PT5S0000C 00100F 8 UPB160L 4PT5S0000C 00100F 6 125A UPB160L 3PT5S0000C 00125F 8 UPB160L 4PT5S0000C 00125F 6 160A UPB160L 3PT5S0000C 00160F 8 UPB160L 4PT5S0000C 00160F 6 100A UPB160X 3PT5S0000C 00100F 8 UPB160X 4PT5S0000C 00100F 6 125A UPB160X 3PT5S0000C 00125F 8 UPB160X 4PT5S0000C 00125F 6 160A UPB160X 3PT5S0000C 00160F 8 UPB160X 4PT5S0000C 00160F 6 Code Unit (EA) Specification Screw type terminal connection, No option, 50/60Hz Category MCCB /M2 �Adjustable thermal & adjustable instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V 3 pole 4 pole Rated current Code Unit (EA) 100A UPB160S 3PT4S0000C 00100H 8 UPB160S 4PT4S0000C 00100H 6 125A UPB160S 3PT4S0000C 00125H 8 UPB160S 4PT4S0000C 00125H 6 160A UPB160S 3PT4S0000C 00160H 8 UPB160S 4PT4S0000C 00160H 6 100A UPB160H 3PT4S0000C 00100H 8 UPB160H 4PT4S0000C 00100H 6 125A UPB160H 3PT4S0000C 00125H 8 UPB160H 4PT4S0000C 00125H 6 160A UPB160H 3PT4S0000C 00160H 8 UPB160H 4PT4S0000C 00160H 6 100A UPB160L 3PT4S0000C 00100H 8 UPB160L 4PT4S0000C 00100H 6 125A UPB160L 3PT4S0000C 00125H 8 UPB160L 4PT4S0000C 00125H 6 160A UPB160L 3PT4S0000C 00160H 8 UPB160L 4PT4S0000C 00160H 6 100A UPB160X 3PT4S0000C 00100H 8 UPB160X 4PT4S0000C 00100H 6 UPB160X 150kA 125A UPB160X 3PT4S0000C 00125H 8 UPB160X 4PT4S0000C 00125H 6 160A UPB160X 3PT4S0000C 00160H 8 UPB160X 4PT4S0000C 00160H 6 Model / Breaking capacity at AC380/415V Rated current Code Unit (EA) 100A UPB160S 3PT5S0000C 00100H 8 UPB160S 4PT5S0000C 00100H 6 125A UPB160S 3PT5S0000C 00125H 8 UPB160S 4PT5S0000C 00125H 6 160A UPB160S 3PT5S0000C 00160H 8 UPB160S 4PT5S0000C 00160H 6 100A UPB160H 3PT5S0000C 00100H 8 UPB160H 4PT5S0000C 00100H 6 125A UPB160H 3PT5S0000C 00125H 8 UPB160H 4PT5S0000C 00125H 6 160A UPB160H 3PT5S0000C 00160H 8 UPB160H 4PT5S0000C 00160H 6 100A UPB160L 3PT5S0000C 00100H 8 UPB160L 4PT5S0000C 00100H 6 125A UPB160L 3PT5S0000C 00125H 8 UPB160L 4PT5S0000C 00125H 6 160A UPB160L 3PT5S0000C 00160H 8 UPB160L 4PT5S0000C 00160H 6 100A UPB160X 3PT5S0000C 00100H 8 UPB160X 4PT5S0000C 00100H 6 125A UPB160X 3PT5S0000C 00125H 8 UPB160X 4PT5S0000C 00125H 6 160A UPB160X 3PT5S0000C 00160H 8 UPB160X 4PT5S0000C 00160H 6 UPB160S 85kA UPB160H 100kA UPB160L 130kA Code Unit (EA) Specification Screw type terminal connection, No option, 50/60Hz Category MCCB /M2 50℃ UPB160S 85kA UPB160H 100kA UPB160L 130kA UPB160X 150kA 3 pole 4 pole Code Unit (EA) Specification Screw type terminal connection, No option, 50/60Hz Category MCCB /M2 Molded Case Circuit Breaker_ 101 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UPB type / 250AF | �UPB250S 85kA �UPB250H 100kA �UPB250L 130kA �UPB250X 150kA UPB250S UPB250H UPB250L Number of poles (P) 3, 4 Degree of protection (with terminal cover) IP20 Utilization category A Suitability of isolation ○ Protection overload, inst., short-circuit Rated current (A) Thermal magnetic type 125,150,160,175,200,225,250 Electronic type 100-250 Rated insulation voltage [Ui] (V) AC750 Rating AC690 Rated operational voltage [Ue] (V) DC500 1) Rated impulse withstand voltage [Uimp] (kV) AC660/690V, 50-60Hz Rated short-circuit breaking capacity Ultimate [Icu] (kA r.m.s.) IEC 60947-2 K 60947-2 10 AC480/500V, 50-60Hz 50 65 85 85 AC440/460V, 50-60Hz 65 85 100 150 AC380/415V, 50-60Hz 85 100 130 150 AC220/240V, 50-60Hz 100 130 150 200 DC250V 50 1) 65 1) 85 1) 100 1) DC125V 65 1) 100 1) 100 1) 100 1) Trip mechanism & Protection characteristics ○ Fixed instantaneous INST 10×In Adjustable thermal, LTD (0.8-0.9-1)×In Fixed instantaneous INST 10×In Adjustable thermal, LTD (0.8-0.9-1)×In Adjustable instantaneous INST Electronic LTD Short time delay STD Instantaneous INST 11×In Pre-trip alarm PTA 0.9×Ir Durability (times) ○ for Switchboard Line side only Screw ○ d c 3/4P 25,000 10,000 a Width 105/140 b Height 165 c Depth 86.5 d Weight (kg, breaker only) 3/4P ○2) ○ Bus bar Electrical operation b (NON-2-3-4-5-6-7-8-9-10)×Ir ○2) Both line & load side Mechanical operation a Dimensions (mm) 100,110,125,140,160,175,200,225,250 ○ Direct mounting by screw Terminal connection (5-6-7-8-9-10)×In Long time delay Pick-up LED Plug-in 25 100 Fixed thermal, Thermal magnetic 8 10 Service [Ics] % of [Icu] Mounting 112 2.0/2.4 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) DC is not applicable for electronic breaker. 2) Available for 3P breaker 102 UPB250X 25 MCCB ■ Accessories �Signal 1ab, Right-hand-side Auxiliary switch AUX 12UP R1 1ab, Left-hand-side Trip alarm switch ALT 12UP L1 Shunt trip 1) Under voltage trip 2) DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V SHT 12UP A SHT 12UP C SHT 12UP F SHT 12UP H SHT 12UP B SHT 12UP D DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V �UVT 12UP J �UVT 12UP L �UVT 12UP N �UVT 12UP P �UVT 12UP Q �UVT 12UP R ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. �Operating Power supply direction S type Operating Surface L type handle 1) S type Extended L type Upper Right Left TFG 12UPS U4 TFG 12UPS R4 TFG 12UPS L4 - TFG 12UPL L4 TFG 12UPL U4 TFH 12UPS TFH 12UPL DC24V Motor operator 2) AC/DC110V MOT 12UP DC24 Mechanical interlock MOT 12UP ADC110 AC/DC220V MOT 12UP ADC220 3 pole 4 pole MIF 12UP 3 MIF 12UP 4 Padlock plate PLD 12UP ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting For both line & load side For line side only TDM 12NEP TDM 12NEF Connection 6C contact CBM 26NE 6 - block 2) CBM 26NE 12 - Structure Plug-in 1) Mounting base 12C contact ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal Terminal bus bar Cage terminal block Terminal cover 1) Interpole barrier 2) 3 pole (6EA/SET) TBB 12NE 3 4 pole (8EA/SET) TBB 12NE 4 3EA/SET CTB 12UP 3S 4EA/SET CTB 12UP 4S 3 pole TCF 12UP 3 4 pole TCF 12UP 4 4EA/SET TQQ 12NE ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 3 pole 4EA, 4 pole 6EA Molded Case Circuit Breaker_ 103 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit �Electronic - LTD, STD, INST trip 3 pole Code 4 pole Code Model / Breaking capacity at AC380/415V Rated current UPB250S 85kA 250A UPB250S 3PESS0000X 00250 8 UPB250S 4PESS0000X 00250 6 UPB250H 100kA 250A UPB250H 3PESS0000X 00250 8 UPB250H 4PESS0000X 00250 6 UPB250L 130kA 250A UPB250L 3PESS0000X 00250 8 UPB250L 4PESS0000X 00250 6 UPB250X 150kA 250A UPB250X 3PESS0000X 00250 8 UPB250X 4PESS0000X 00250 6 UPB250S 85kA 250A UPB250S 3PESS0000Y 00250 8 UPB250S 4PESS0000Y 00250 6 UPB250H 100kA 250A UPB250H 3PESS0000Y 00250 8 UPB250H 4PESS0000Y 00250 6 UPB250L 130kA 250A UPB250L 3PESS0000Y 00250 8 UPB250L 4PESS0000Y 00250 6 UPB250X 150kA 250A UPB250X 3PESS0000Y 00250 8 UPB250X 4PESS0000Y 00250 6 Unit (EA) Unit (EA) Specification Category Screw type terminal connection, No option, 50Hz MCCB /M3 Screw type terminal connection, No option, 60Hz �Electronic - LTD, STD, INST, GFT trip & PTA 104 3 pole Code 4 pole Code Model / Breaking capacity at AC380/415V Rated current UPB250S 85kA 250A UPB250S 3PGSS0000X 00250 8 UPB250S 4PGSS0000X 00250 6 UPB250H 100kA 250A UPB250H 3PGSS0000X 00250 8 UPB250H 4PGSS0000X 00250 6 UPB250L 130kA 250A UPB250L 3PGSS0000X 00250 8 UPB250L 4PGSS0000X 00250 6 UPB250X 150kA 250A UPB250X 3PGSS0000X 00250 8 UPB250X 4PGSS0000X 00250 6 UPB250S 85kA 250A UPB250S 3PGSS0000Y 00250 8 UPB250S 4PGSS0000Y 00250 6 UPB250H 100kA 250A UPB250H 3PGSS0000Y 00250 8 UPB250H 4PGSS0000Y 00250 6 UPB250L 130kA 250A UPB250L 3PGSS0000Y 00250 8 UPB250L 4PGSS0000Y 00250 6 UPB250X 150kA 250A UPB250X 3PGSS0000Y 00250 8 UPB250X 4PGSS0000Y 00250 6 Unit (EA) Unit (EA) Specification Category Screw type terminal connection, No option, 50Hz MCCB /M3 Screw type terminal connection, No option, 60Hz MCCB ■ Standard order code and unit �Fixed thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UPB250S 85kA UPB250H 100kA UPB250L 130kA UPB250X 150kA Rated current 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 3 pole Code UPB250S 3PT4S0000C 00125 UPB250S 3PT4S0000C 00150 UPB250S 3PT4S0000C 00160 UPB250S 3PT4S0000C 00175 UPB250S 3PT4S0000C 00200 UPB250S 3PT4S0000C 00225 UPB250S 3PT4S0000C 00250 UPB250H 3PT4S0000C 00125 UPB250H 3PT4S0000C 00150 UPB250H 3PT4S0000C 00160 UPB250H 3PT4S0000C 00175 UPB250H 3PT4S0000C 00200 UPB250H 3PT4S0000C 00225 UPB250H 3PT4S0000C 00250 UPB250L 3PT4S0000C 00125 UPB250L 3PT4S0000C 00150 UPB250L 3PT4S0000C 00160 UPB250L 3PT4S0000C 00175 UPB250L 3PT4S0000C 00200 UPB250L 3PT4S0000C 00225 UPB250L 3PT4S0000C 00250 UPB250X 3PT4S0000C 00125 UPB250X 3PT4S0000C 00150 UPB250X 3PT4S0000C 00160 UPB250X 3PT4S0000C 00175 UPB250X 3PT4S0000C 00200 UPB250X 3PT4S0000C 00225 UPB250X 3PT4S0000C 00250 Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 4 pole Code UPB250S 4PT4S0000C 00125 UPB250S 4PT4S0000C 00150 UPB250S 4PT4S0000C 00160 UPB250S 4PT4S0000C 00175 UPB250S 4PT4S0000C 00200 UPB250S 4PT4S0000C 00225 UPB250S 4PT4S0000C 00250 UPB250H 4PT4S0000C 00125 UPB250H 4PT4S0000C 00150 UPB250H 4PT4S0000C 00160 UPB250H 4PT4S0000C 00175 UPB250H 4PT4S0000C 00200 UPB250H 4PT4S0000C 00225 UPB250H 4PT4S0000C 00250 UPB250L 4PT4S0000C 00125 UPB250L 4PT4S0000C 00150 UPB250L 4PT4S0000C 00160 UPB250L 4PT4S0000C 00175 UPB250L 4PT4S0000C 00200 UPB250L 4PT4S0000C 00225 UPB250L 4PT4S0000C 00250 UPB250X 4PT4S0000C 00125 UPB250X 4PT4S0000C 00150 UPB250X 4PT4S0000C 00160 UPB250X 4PT4S0000C 00175 UPB250X 4PT4S0000C 00200 UPB250X 4PT4S0000C 00225 UPB250X 4PT4S0000C 00250 Unit (EA) 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UPB250S 85kA UPB250H 100kA UPB250L 130kA UPB250X 150kA Rated current 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 3 pole Code UPB250S 3PT5S0000C 00125 UPB250S 3PT5S0000C 00150 UPB250S 3PT5S0000C 00160 UPB250S 3PT5S0000C 00175 UPB250S 3PT5S0000C 00200 UPB250S 3PT5S0000C 00225 UPB250S 3PT5S0000C 00250 UPB250H 3PT5S0000C 00125 UPB250H 3PT5S0000C 00150 UPB250H 3PT5S0000C 00160 UPB250H 3PT5S0000C 00175 UPB250H 3PT5S0000C 00200 UPB250H 3PT5S0000C 00225 UPB250H 3PT5S0000C 00250 UPB250L 3PT5S0000C 00125 UPB250L 3PT5S0000C 00150 UPB250L 3PT5S0000C 00160 UPB250L 3PT5S0000C 00175 UPB250L 3PT5S0000C 00200 UPB250L 3PT5S0000C 00225 UPB250L 3PT5S0000C 00250 UPB250X 3PT5S0000C 00125 UPB250X 3PT5S0000C 00150 UPB250X 3PT5S0000C 00160 UPB250X 3PT5S0000C 00175 UPB250X 3PT5S0000C 00200 UPB250X 3PT5S0000C 00225 UPB250X 3PT5S0000C 00250 Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 4 pole Code UPB250S 4PT5S0000C 00125 UPB250S 4PT5S0000C 00150 UPB250S 4PT5S0000C 00160 UPB250S 4PT5S0000C 00175 UPB250S 4PT5S0000C 00200 UPB250S 4PT5S0000C 00225 UPB250S 4PT5S0000C 00250 UPB250H 4PT5S0000C 00125 UPB250H 4PT5S0000C 00150 UPB250H 4PT5S0000C 00160 UPB250H 4PT5S0000C 00175 UPB250H 4PT5S0000C 00200 UPB250H 4PT5S0000C 00225 UPB250H 4PT5S0000C 00250 UPB250L 4PT5S0000C 00125 UPB250L 4PT5S0000C 00150 UPB250L 4PT5S0000C 00160 UPB250L 4PT5S0000C 00175 UPB250L 4PT5S0000C 00200 UPB250L 4PT5S0000C 00225 UPB250L 4PT5S0000C 00250 UPB250X 4PT5S0000C 00125 UPB250X 4PT5S0000C 00150 UPB250X 4PT5S0000C 00160 UPB250X 4PT5S0000C 00175 UPB250X 4PT5S0000C 00200 UPB250X 4PT5S0000C 00225 UPB250X 4PT5S0000C 00250 Unit (EA) 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Molded Case Circuit Breaker_ 105 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit �Adjustable thermal & fixed instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UPB250S 85kA UPB250H 100kA UPB250L 130kA UPB250X 150kA Rated current 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 3 pole Code UPB250S 3PT4S0000C 00125F UPB250S 3PT4S0000C 00150F UPB250S 3PT4S0000C 00160F UPB250S 3PT4S0000C 00175F UPB250S 3PT4S0000C 00200F UPB250S 3PT4S0000C 00225F UPB250S 3PT4S0000C 00250F UPB250H 3PT4S0000C 00125F UPB250H 3PT4S0000C 00150F UPB250H 3PT4S0000C 00160F UPB250H 3PT4S0000C 00175F UPB250H 3PT4S0000C 00200F UPB250H 3PT4S0000C 00225F UPB250H 3PT4S0000C 00250F UPB250L 3PT4S0000C 00125F UPB250L 3PT4S0000C 00150F UPB250L 3PT4S0000C 00160F UPB250L 3PT4S0000C 00175F UPB250L 3PT4S0000C 00200F UPB250L 3PT4S0000C 00225F UPB250L 3PT4S0000C 00250F UPB250X 3PT4S0000C 00125F UPB250X 3PT4S0000C 00150F UPB250X 3PT4S0000C 00160F UPB250X 3PT4S0000C 00175F UPB250X 3PT4S0000C 00200F UPB250X 3PT4S0000C 00225F UPB250X 3PT4S0000C 00250F Unit (EA) 4 pole Code Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 UPB250S 4PT4S0000C 00125F UPB250S 4PT4S0000C 00150F UPB250S 4PT4S0000C 00160F UPB250S 4PT4S0000C 00175F UPB250S 4PT4S0000C 00200F UPB250S 4PT4S0000C 00225F UPB250S 4PT4S0000C 00250F UPB250H 4PT4S0000C 00125F UPB250H 4PT4S0000C 00150F UPB250H 4PT4S0000C 00160F UPB250H 4PT4S0000C 00175F UPB250H 4PT4S0000C 00200F UPB250H 4PT4S0000C 00225F UPB250F 4PT4S0000C 00250F UPB250L 4PT4S0000C 00125F UPB250L 4PT4S0000C 00150F UPB250L 4PT4S0000C 00160F UPB250L 4PT4S0000C 00175F UPB250L 4PT4S0000C 00200F UPB250L 4PT4S0000C 00225F UPB250L 4PT4S0000C 00250F UPB250X 4PT4S0000C 00125F UPB250X 4PT4S0000C 00150F UPB250X 4PT4S0000C 00160F UPB250X 4PT4S0000C 00175F UPB250X 4PT4S0000C 00200F UPB250X 4PT4S0000C 00225F UPB250X 4PT4S0000C 00250F 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Unit (EA) 4 pole Code Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 UPB250S 4PT5S0000C 00125F UPB250S 4PT5S0000C 00150F UPB250S 4PT5S0000C 00160F UPB250S 4PT5S0000C 00175F UPB250S 4PT5S0000C 00200F UPB250S 4PT5S0000C 00225F UPB250S 4PT5S0000C 00250F UPB250H 4PT5S0000C 00125F UPB250H 4PT5S0000C 00150F UPB250H 4PT5S0000C 00160F UPB250H 4PT5S0000C 00175F UPB250H 4PT5S0000C 00200F UPB250H 4PT5S0000C 00225F UPB250F 4PT5S0000C 00250F UPB250L 4PT5S0000C 00125F UPB250L 4PT5S0000C 00150F UPB250L 4PT5S0000C 00160F UPB250L 4PT5S0000C 00175F UPB250L 4PT5S0000C 00200F UPB250L 4PT5S0000C 00225F UPB250L 4PT5S0000C 00250F UPB250X 4PT5S0000C 00125F UPB250X 4PT5S0000C 00150F UPB250X 4PT5S0000C 00160F UPB250X 4PT5S0000C 00175F UPB250X 4PT5S0000C 00200F UPB250X 4PT5S0000C 00225F UPB250X 4PT5S0000C 00250F 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UPB250S 85kA UPB250H 100kA UPB250L 130kA UPB250X 150kA 106 Rated current 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 3 pole Code UPB250S 3PT5S0000C 00125F UPB250S 3PT5S0000C 00150F UPB250S 3PT5S0000C 00160F UPB250S 3PT5S0000C 00175F UPB250S 3PT5S0000C 00200F UPB250S 3PT5S0000C 00225F UPB250S 3PT5S0000C 00250F UPB250H 3PT5S0000C 00125F UPB250H 3PT5S0000C 00150F UPB250H 3PT5S0000C 00160F UPB250H 3PT5S0000C 00175F UPB250H 3PT5S0000C 00200F UPB250H 3PT5S0000C 00225F UPB250H 3PT5S0000C 00250F UPB250L 3PT5S0000C 00125F UPB250L 3PT5S0000C 00150F UPB250L 3PT5S0000C 00160F UPB250L 3PT5S0000C 00175F UPB250L 3PT5S0000C 00200F UPB250L 3PT5S0000C 00225F UPB250L 3PT5S0000C 00250F UPB250X 3PT5S0000C 00125F UPB250X 3PT5S0000C 00150F UPB250X 3PT5S0000C 00160F UPB250X 3PT5S0000C 00175F UPB250X 3PT5S0000C 00200F UPB250X 3PT5S0000C 00225F UPB250X 3PT5S0000C 00250F MCCB ■ Standard order code and unit �Adjustable thermal & adjustable instantaneous / Thermal magnetic trip 40/45℃ Model / Breaking capacity at AC380/415V UPB250S 85kA UPB250H 100kA UPB250L 130kA UPB250X 150kA Rated current 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 3 pole Code UPB250S 3PT4S0000C 00125H UPB250S 3PT4S0000C 00150H UPB250S 3PT4S0000C 00160H UPB250S 3PT4S0000C 00175H UPB250S 3PT4S0000C 00200H UPB250S 3PT4S0000C 00225H UPB250S 3PT4S0000C 00250H UPB250H 3PT4S0000C 00125H UPB250H 3PT4S0000C 00150H UPB250H 3PT4S0000C 00160H UPB250H 3PT4S0000C 00175H UPB250H 3PT4S0000C 00200H UPB250H 3PT4S0000C 00225H UPB250H 3PT4S0000C 00250H UPB250L 3PT4S0000C 00125H UPB250L 3PT4S0000C 00150H UPB250L 3PT4S0000C 00160H UPB250L 3PT4S0000C 00175H UPB250L 3PT4S0000C 00200H UPB250L 3PT4S0000C 00225H UPB250L 3PT4S0000C 00250H UPB250X 3PT4S0000C 00125H UPB250X 3PT4S0000C 00150H UPB250X 3PT4S0000C 00160H UPB250X 3PT4S0000C 00175H UPB250X 3PT4S0000C 00200H UPB250X 3PT4S0000C 00225H UPB250X 3PT4S0000C 00250H Unit (EA) 4 pole Code Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 UPB250S 4PT4S0000C 00125H UPB250S 4PT4S0000C 00150H UPB250S 4PT4S0000C 00160H UPB250S 4PT4S0000C 00175H UPB250S 4PT4S0000C 00200H UPB250S 4PT4S0000C 00225H UPB250S 4PT4S0000C 00250H UPB250H 4PT4S0000C 00125H UPB250H 4PT4S0000C 00150H UPB250H 4PT4S0000C 00160H UPB250H 4PT4S0000C 00175H UPB250H 4PT4S0000C 00200H UPB250H 4PT4S0000C 00225H UPB250H 4PT4S0000C 00250H UPB250L 4PT4S0000C 00125H UPB250L 4PT4S0000C 00150H UPB250L 4PT4S0000C 00160H UPB250L 4PT4S0000C 00175H UPB250L 4PT4S0000C 00200H UPB250L 4PT4S0000C 00225H UPB250L 4PT4S0000C 00250H UPB250X 4PT4S0000C 00125H UPB250X 4PT4S0000C 00150H UPB250X 4PT4S0000C 00160H UPB250X 4PT4S0000C 00175H UPB250X 4PT4S0000C 00200H UPB250X 4PT4S0000C 00225H UPB250X 4PT4S0000C 00250H 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Unit (EA) 4 pole Code Unit (EA) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 UPB250S 4PT5S0000C 00125H UPB250S 4PT5S0000C 00150H UPB250S 4PT5S0000C 00160H UPB250S 4PT5S0000C 00175H UPB250S 4PT5S0000C 00200H UPB250S 4PT5S0000C 00225H UPB250S 4PT5S0000C 00250H UPB250H 4PT5S0000C 00125H UPB250H 4PT5S0000C 00150H UPB250H 4PT5S0000C 00160H UPB250H 4PT5S0000C 00175H UPB250H 4PT5S0000C 00200H UPB250H 4PT5S0000C 00225H UPB250H 4PT5S0000C 00250H UPB250L 4PT5S0000C 00125H UPB250L 4PT5S0000C 00150H UPB250L 4PT5S0000C 00160H UPB250L 4PT5S0000C 00175H UPB250L 4PT5S0000C 00200H UPB250L 4PT5S0000C 00225H UPB250L 4PT5S0000C 00250H UPB250X 4PT5S0000C 00125H UPB250X 4PT5S0000C 00150H UPB250X 4PT5S0000C 00160H UPB250X 4PT5S0000C 00175H UPB250X 4PT5S0000C 00200H UPB250X 4PT5S0000C 00225H UPB250X 4PT5S0000C 00250H 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M2 50℃ Model / Breaking capacity at AC380/415V UPB250S 85kA UPB250H 100kA UPB250L 130kA UPB250X 150kA Rated current 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 125A 150A 160A 175A 200A 225A 250A 3 pole Code UPB250S 3PT5S0000C 00125H UPB250S 3PT5S0000C 00150H UPB250S 3PT5S0000C 00160H UPB250S 3PT5S0000C 00175H UPB250S 3PT5S0000C 00200H UPB250S 3PT5S0000C 00225H UPB250S 3PT5S0000C 00250H UPB250H 3PT5S0000C 00125H UPB250H 3PT5S0000C 00150H UPB250H 3PT5S0000C 00160H UPB250H 3PT5S0000C 00175H UPB250H 3PT5S0000C 00200H UPB250H 3PT5S0000C 00225H UPB250H 3PT5S0000C 00250H UPB250L 3PT5S0000C 00125H UPB250L 3PT5S0000C 00150H UPB250L 3PT5S0000C 00160H UPB250L 3PT5S0000C 00175H UPB250L 3PT5S0000C 00200H UPB250L 3PT5S0000C 00225H UPB250L 3PT5S0000C 00250H UPB250X 3PT5S0000C 00125H UPB250X 3PT5S0000C 00150H UPB250X 3PT5S0000C 00160H UPB250X 3PT5S0000C 00175H UPB250X 3PT5S0000C 00200H UPB250X 3PT5S0000C 00225H UPB250X 3PT5S0000C 00250H Molded Case Circuit Breaker_ 107 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UPB type / 400AF | �UPB400S 85kA �UPB400H 100kA �UPB400L 130kA �UPB400X 150kA UPB400S Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) AC660/690V, 50-60Hz Rated AC480/500V, 50-60Hz short-circuit Ultimate breaking [Icu] AC440/460V, 50-60Hz capacity (kA r.m.s.) AC380/415V, 50-60Hz AC220/240V, 50-60Hz IEC 60947-2 K 60947-2 Service [Ics] % of [Icu] Long time delay LTD Short time delay STD Trip Instantaneous INST mechanism Ground fault trip GFT Electronic & Protection Pre-trip alarm PTA characteristics I2T lamp Pick-up LED Direct mounting by screw Mounting Both line & load side for Plug-in Switchboard Line side only Screw Terminal connection Bus bar Durability Mechanical operation (times) Electrical operation a Width d a c Dimensions b Height 3/4P b (mm) c Depth d Weight (kg, breaker only) 3/4P UPB400H UPB400L 3, 4 IP20 A ○ overload, inst., short-circuit 200-400 AC750 AC690 8 10 25 65 85 85 100 100 130 130 150 100 (0.5-1) 1) ×In (15 setting) (2-4-6-8-10)×Ir (3-6-8-10-11)×In (0.2-0.3-0.4)×In 0.9×Ir ○ ○ ○ ○2) ○2) ○ ○ 20,000 6,000 140/185 255 117 159.5 6.0/7.8 10 50 65 85 100 UPB400X 25 85 150 150 200 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) (0.5-1): (0.63-0.8-1)x(0.8-0.85-0.9-0.95-1) 2) Available for 3P breaker ■ Accessories �Signal Auxiliary switch Trip alarm switch Shunt trip 1) Under voltage trip 2) 1ab, Left-hand-side AUX 46UP L1 1ab, Right-hand-side ALT 46UP R1 DC24V SHT 46UP A DC24V �UVT 46UP J DC100-110V SHT 46UP C DC100-110V �UVT 46UP L AC100-120V SHT 46UP F AC100-120V �UVT 46UP N ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. 108 AC200-230V SHT 46UP H AC200-230V �UVT 46UP P AC380-415V SHT 46UP B AC380-415V �UVT 46UP Q AC440-480V SHT 46UP D AC440-480V �UVT 46UP R MCCB �Operating Power supply direction Operating Surface S type handle 1) Extended S type Motor operator Upper Right Left TFG 46UPS U2 TFG 46UPS R2 TFG 46UPS L2 DC24V AC/DC110V AC/DC220V MOT 46UP DC24 MOT 46UP ADC110 MOT 46UP ADC220 TFH 46UPS 2) Mechanical interlock 3 pole 4 pole MIF 46UP 3 MIF 46UP 4 Padlock plate PDA 12UP Extension handle 3) THA 46UP ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. 3) Supplied as standard component �Mounting Plug-in 1) Structure Mounting base Connection 6C contact block 2) 12C contact For both line & load side TDM 46NEP 3) CBM 26NE 6 CBM 26NE 12 For line side only TDM 46NEF - ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. 3) 2EA are required for both line & load side plug-in type 3P breaker. �Terminal 3 pole (6EA/SET) 4 pole (8EA/SET) 3EA/SET Cage terminal block 4EA/SET 3 pole 1) Terminal cover 4 pole Interpole barrier 2) 4EA/SET TBB 40NE 3 TBB 40NE 4 CTB 46UP 3S CTB 46UP 4S TCF 46UP 3 TCF 46UP 4 TQQ 46NE Terminal bus bar ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 3 pole 4EA, 4 pole 6EA ■ Standard order code and unit �Electronic - LTD, STD, INST trip Model / Breaking capacity at AC380/415V UPB400S 85kA UPB400H 100kA UPB400L 130kA UPB400X 150kA UPB400S 85kA UPB400H 100kA UPB400L 130kA UPB400X 150kA Rated current 400A 400A 400A 400A 400A 400A 400A 400A 3 pole Code UPB400S 3PESS0000X 00400 UPB400H 3PESS0000X 00400 UPB400L 3PESS0000X 00400 UPB400X 3PESS0000X 00400 UPB400S 3PESS0000Y 00400 UPB400H 3PESS0000Y 00400 UPB400L 3PESS0000Y 00400 UPB400X 3PESS0000Y 00400 4 pole Unit (EA) Code Unit (EA) 3 3 3 3 3 3 3 3 UPB400S 4PESS0000X 00400 UPB400H 4PESS0000X 00400 UPB400L 4PESS0000X 00400 UPB400X 4PESS0000X 00400 UPB400S 4PESS0000Y 00400 UPB400H 4PESS0000Y 00400 UPB400L 4PESS0000Y 00400 UPB400X 4PESS0000Y 00400 2 2 2 2 2 2 2 2 Specification Category Screw type terminal connection, No option, 50Hz MCCB/M3 Screw type terminal connection, No option, 60Hz �Electronic - LTD, STD, INST, GFT trip & PTA Model / Breaking capacity at AC380/415V UPB400S 85kA UPB400H 100kA UPB400L 130kA UPB400X 150kA UPB400S 85kA UPB400H 100kA UPB400L 130kA UPB400X 150kA Rated current 400A 400A 400A 400A 400A 400A 400A 400A 3 pole Code UPB400S 3PGSS0000X 00400 UPB400H 3PGSS0000X 00400 UPB400L 3PGSS0000X 00400 UPB400X 3PGSS0000X 00400 UPB400S 3PGSS0000Y 00400 UPB400H 3PGSS0000Y 00400 UPB400L 3PGSS0000Y 00400 UPB400X 3PGSS0000Y 00400 4 pole Unit (EA) Code Unit (EA) 3 3 3 3 3 3 3 3 UPB400S 4PGSS0000X 00400 UPB400H 4PGSS0000X 00400 UPB400L 4PGSS0000X 00400 UPB400X 4PGSS0000X 00400 UPB400S 4PGSS0000Y 00400 UPB400H 4PGSS0000Y 00400 UPB400L 4PGSS0000Y 00400 UPB400X 4PGSS0000Y 00400 2 2 2 2 2 2 2 2 Specification Category Screw type terminal connection, No option, 50Hz MCCB/M3 Screw type terminal connection, No option, 60Hz Molded Case Circuit Breaker_ 109 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | UPB type / 630AF | �UPB630S 85kA �UPB630H 100kA �UPB630L 130kA �UPB630X 150kA UPB630S Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) AC660/690V, 50-60Hz Rated AC480/500V, 50-60Hz short-circuit Ultimate breaking [Icu] AC440/460V, 50-60Hz capacity (kA r.m.s.) AC380/415V, 50-60Hz AC220/240V, 50-60Hz IEC 60947-2 K 60947-2 Service [Ics] % of [Icu] Long time delay LTD Short time delay STD Trip Instantaneous INST mechanism GFT Electronic Ground fault trip & Protection Pre-trip alarm PTA characteristics I2T lamp Pick-up LED Direct mounting by screw Mounting Both line & load side for Plug-in Switchboard Line side only Screw Terminal connection Bus bar Mechanical operation Durability (times) Electrical operation a Width d a c b Height Dimensions 3/4P b (mm) c Depth d Weight (kg, breaker only) 3/4P UPB630H UPB630L 3, 4 IP20 A ○ overload, inst., short-circuit 320-630 AC750 AC690 8 10 25 65 85 85 100 100 130 130 150 100 (0.5-1) 1) ×In (15 setting) (2-4-6-8-10)×Ir (3-6-8-10-11)×In (0.2-0.3-0.4)×In 0.9×Ir ○ ○ ○ ○2) ○2) ○ ○ 20,000 6,000 140/185 255 117 159.5 6.0/7.8 10 50 65 85 100 UPB630X 25 85 150 150 200 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) (0.5-1): (0.63-0.8-1)x(0.8-0.85-0.9-0.95-1) 2) Available for 3P breaker ■ Accessories �Signal Auxiliary switch Trip alarm switch Shunt trip 1) Under voltage trip 2) 1ab, Left-hand-side AUX 46UP L1 1ab, Right-hand-side ALT 46UP R1 DC24V SHT 46UP A DC24V �UVT 46UP J DC100-110V SHT 46UP C DC100-110V �UVT 46UP L AC100-120V SHT 46UP F AC100-120V �UVT 46UP N ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. 110 AC200-230V SHT 46UP H AC200-230V �UVT 46UP P AC380-415V SHT 46UP B AC380-415V �UVT 46UP Q AC440-480V SHT 46UP D AC440-480V �UVT 46UP R MCCB �Operating Power supply direction Operating Surface S type handle 1) Extended S type Motor operator Upper Right Left TFG 46UPS U2 TFG 46UPS R2 TFG 46UPS L2 DC24V AC/DC110V AC/DC220V MOT 46UP DC24 MOT 46UP ADC110 MOT 46UP ADC220 TFH 46UPS 2) Mechanical interlock 3 pole 4 pole MIF 46UP 3 MIF 46UP 4 Padlock plate PDA 12UP Extension handle 3) THA 46UP ※ 1) For detail type information, please refer to page no. 201-209. 2) Motor operator is not recommended for marine application. 3) Supplied as standard component �Mounting Plug-in 1) Structure Mounting base Connection 6C contact block 2) 12C contact For both line & load side TDM 46NEP 3) CBM 26NE 6 CBM 26NE 12 For line side only TDM 46NEF - ※ 1) Available for 3P breaker 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. 3) 2EA are required for both line & load side plug-in type 3P breaker. �Terminal 3 pole (6EA/SET) 4 pole (8EA/SET) 3EA/SET Cage terminal block 4EA/SET 3 pole 1) Terminal cover 4 pole Interpole barrier 2) 4EA/SET TBB 60NE 3 TBB 60NE 4 CTB 46UP 3S CTB 46UP 4S TCF 46UP 3 TCF 46UP 4 TQQ 46NE Terminal bus bar ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 3 pole 4EA, 4 pole 6EA ■ Standard order code and unit �Electronic - LTD, STD, INST trip Model / Breaking capacity at AC380/415V UPB630S 85kA UPB630H 100kA UPB630L 130kA UPB630X 150kA UPB630S 85kA UPB630H 100kA UPB630L 130kA UPB630X 150kA Rated current 630A 630A 630A 630A 630A 630A 630A 630A 3 pole Code UPB630S 3PESS0000X 00630 UPB630H 3PESS0000X 00630 UPB630L 3PESS0000X 00630 UPB630X 3PESS0000X 00630 UPB630S 3PESS0000Y 00630 UPB630H 3PESS0000Y 00630 UPB630L 3PESS0000Y 00630 UPB630X 3PESS0000Y 00630 4 pole Unit (EA) Code Unit (EA) 3 3 3 3 3 3 3 3 UPB630S 4PESS0000X 00630 UPB630H 4PESS0000X 00630 UPB630L 4PESS0000X 00630 UPB630X 4PESS0000X 00630 UPB630S 4PESS0000Y 00630 UPB630H 4PESS0000Y 00630 UPB630L 4PESS0000Y 00630 UPB630X 4PESS0000Y 00630 2 2 2 2 2 2 2 2 Specification Category Screw type terminal connection, No option, 50Hz MCCB/M3 Screw type terminal connection, No option, 60Hz �Electronic - LTD, STD, INST, GFT trip & PTA Model / Breaking capacity at AC380/415V UPB630S 85kA UPB630H 100kA UPB630L 130kA UPB630X 150kA UPB630S 85kA UPB630H 100kA UPB630L 130kA UPB630X 150kA Rated current 630A 630A 630A 630A 630A 630A 630A 630A 3 pole Code UPB630S 3PGSS0000X 00630 UPB630H 3PGSS0000X 00630 UPB630L 3PGSS0000X 00630 UPB630X 3PGSS0000X 00630 UPB630S 3PGSS0000Y 00630 UPB630H 3PGSS0000Y 00630 UPB630L 3PGSS0000Y 00630 UPB630X 3PGSS0000Y 00630 4 pole Unit (EA) Code Unit (EA) 3 3 3 3 3 3 3 3 UPB630S 4PGSS0000X 00630 UPB630H 4PGSS0000X 00630 UPB630L 4PGSS0000X 00630 UPB630X 4PGSS0000X 00630 UPB630S 4PGSS0000Y 00630 UPB630H 4PGSS0000Y 00630 UPB630L 4PGSS0000Y 00630 UPB630X 4PGSS0000Y 00630 2 2 2 2 2 2 2 2 Specification Category Screw type terminal connection, No option, 50Hz MCCB/M3 Screw type terminal connection, No option, 60Hz Molded Case Circuit Breaker_ 111 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | Motor protection / UPB type 125AF | �UPB100H 100kA �UPB100L 130kA UPB100H UPB100L 3 Number of poles (P) IP20 Degree of protection (with terminal cover) Utilization category A Suitability of isolation ○ Protection instantaneous, short-circuit Rated current (A) 2.5,3.2,6.3,12.5,20,32,50,63,80,100 Rated insulation voltage [Ui] (V) AC750 Rating AC690 Rated operational voltage [Ue] (V) DC500 Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit breaking capacity Ultimate [Icu] (kA r.m.s.) IEC 60947-2 K 60947-2 AC660/690V, 50-60Hz 10 25 AC480/500V, 50-60Hz 65 85 AC440/460V, 50-60Hz 85 100 AC380/415V, 50-60Hz 100 130 AC220/240V, 50-60Hz 130 150 DC250V 65 85 DC125V 100 100 Service [Ics] % of [Icu] Trip mechanism Thermal & Protection characteristics magnetic 100 (6-7-8-9-10-11-12-13)×In Adjustable instantaneous ○ Direct mounting by screw Mounting Plug-in Terminal connection Durability (times) Both line & load side for Switchboard Line side only ○ Screw ○ Bus bar ○ ○ Mechanical operation 25,000 Electrical operation 10,000 a Dimensions (mm) 8 d c 3P b a Width 105 b Height 165 c Depth 86.5 d Weight (kg, breaker only) 3P 112 1.8 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 112 MCCB ■ Accessories �Signal 1ab, Right-hand-side AUX 12UP R1 1ab, Left-hand-side ALT 12UP L1 DC24V SHT 12UP A DC24V �UVT 12UP J Auxiliary switch Trip alarm switch Shunt trip 1) Under voltage trip 2) DC100-110V SHT 12UP C DC100-110V �UVT 12UP L AC100-120V SHT 12UP F AC100-120V �UVT 12UP N AC200-230V SHT 12UP H AC200-230V �UVT 12UP P AC380-415V SHT 12UP B AC380-415V �UVT 12UP Q AC440-480V SHT 12UP D AC440-480 �UVT 12UP R ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. �Operating Power supply direction Operating handle 1) Surface Extended Upper Right Left S type TFG 12UPS U4 TFG 12UPS R4 TFG 12UPS L4 L type TFG 12UPL U4 - TFG 12UPL L4 TFH 12UPS S type TFH 12UPL L type Motor operator 2) DC24V AC/DC110V AC/DC220V MOT 12UP DC24 MOT 12UP ADC110 MOT 12UP ADC220 Mechanical interlock MIF 12UP 3 Padlock plate PLD 12UP ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting Plug-in Structure Mounting base Connection 6C contact block 1) 12C contact For both line & load side TDM 12NEP CBM 26NE 6 CBM 26NE 12 For line side only TDM 12NEF - ※ 1) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal Terminal bus bar Cage terminal block 1) Terminal cover Interpole barrier 2) 3 pole (6EA/SET) 3EA/SET TBB 12NE 3 CTB 12UP 3S TCF 12UP 3 TQQ 12NE 3 pole 4EA/SET ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 4EA ■ Standard order code and unit �Adjustable instantaneous only / recommended for motor protection Model / Breaking capacity at AC380/415V Rated current UPB100H 100kA 2.5A 3.2A 6.3A 12.5A 20A 32A 50A 63A 80A 100A 3 pole Code UPB100H 3PMPS0000C 002.5 UPB100H 3PMPS0000C 003.2 UPB100H 3PMPS0000C 006.3 UPB100H 3PMPS0000C 012.5 UPB100H 3PMPS0000C 00020 UPB100H 3PMPS0000C 00032 UPB100H 3PMPS0000C 00050 UPB100H 3PMPS0000C 00063 UPB100H 3PMPS0000C 00080 UPB100H 3PMPS0000C 00100 Unit (EA) 8 8 8 8 8 8 8 8 8 8 Model / Breaking capacity at AC380/415V Rated current UPB100L 130kA 2.5A 3.2A 6.3A 12.5A 20A 32A 50A 63A 80A 100A 3 pole Code Unit (EA) UPB100L 3PMPS0000C 002.5 UPB100L 3PMPS0000C 003.2 UPB100L 3PMPS0000C 006.3 UPB100L 3PMPS0000C 012.5 UPB100L 3PMPS0000C 00020 UPB100L 3PMPS0000C 00032 UPB100L 3PMPS0000C 00050 UPB100L 3PMPS0000C 00063 UPB100L 3PMPS0000C 00080 UPB100L 3PMPS0000C 00100 8 8 8 8 8 8 8 8 8 8 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M4 Molded Case Circuit Breaker_ 113 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | Motor protection / UPB type 250AF | �UPB250H 100kA �UPB250L 130kA UPB250H UPB250L 3 Number of poles (P) IP20 Degree of protection (with terminal cover) Utilization category A Suitability of isolation ○ Protection instantaneous, short-circuit Rated current (A) 125,150,175,200,225 Rated insulation voltage [Ui] (V) AC750 Rating AC690 Rated operational voltage [Ue] (V) DC500 Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit breaking capacity Ultimate [Icu] (kA r.m.s.) IEC 60947-2 K 60947-2 AC660/690V, 50-60Hz 10 25 AC480/500V, 50-60Hz 65 85 AC440/460V, 50-60Hz 85 100 AC380/415V, 50-60Hz 100 130 AC220/240V, 50-60Hz 130 150 DC250V 65 85 DC125V 100 100 Service [Ics] % of [Icu] Trip mechanism Thermal & Protection characteristics magnetic 100 (6-7-8-9-10-11-12-13)×In Adjustable instantaneous ○ Direct mounting by screw Mounting Plug-in Both line & load side for Switchboard Line side only ○ Screw ○ Bus bar ○ Terminal connection Durability (times) ○ Mechanical operation 25,000 Electrical operation 10,000 a Dimensions (mm) 8 a Width 105 b Height 165 c Depth 86.5 d c b 3P d Weight (kg, breaker only) 3P 112 2.0 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 114 MCCB ■ Accessories �Signal 1ab, Right-hand-side AUX 12UP R1 1ab, Left-hand-side ALT 12UP L1 DC24V SHT 12UP A DC24V �UVT 12UP J Auxiliary switch Trip alarm switch Shunt trip 1) Under voltage trip 2) DC100-110V SHT 12UP C DC100-110V �UVT 12UP L AC100-120V SHT 12UP F AC100-120V �UVT 12UP N AC200-230V SHT 12UP H AC200-230V �UVT 12UP P AC380-415V SHT 12UP B AC380-415V �UVT 12UP Q AC440-480V SHT 12UP D AC440-480V �UVT 12UP R ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. �Operating Power supply direction Operating handle 1) Surface Extended Upper Right Left S type TFG 12UPS U4 TFG 12UPS R4 TFG 12UPS L4 L type TFG 12UPL U4 - TFG 12UPL L4 TFH 12UPS S type TFH 12UPL L type Motor operator 2) DC24V AC/DC110V AC/DC220V MOT 12UP DC24 MOT 12UP ADC110 MOT 12UP ADC220 Mechanical interlock MIF 12UP 3 Padlock plate PLD 12UP ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting Plug-in Structure Mounting base Connection 6C contact block 1) 12C contact For both line & load side TDM 12NEP CBM 26NE 6 CBM 26NE 12 For line side only TDM 12NEF - ※ 1) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal Terminal bus bar 3 pole (6EA/SET) Cage terminal block 3EA/SET Terminal cover 1) Interpole barrier 2) TBB 12NE 3 CTB 12UP 3S TCF 12UP 3 TCF 12UP 4 TQQ 12NE 3 pole 4 pole 4EA/SET ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 4EA ■ Standard order code and unit �Adjustable instantaneous only / recommended for motor protection Model / Breaking capacity at AC380/415V UPB250H 100kA Rated current 3 pole Code Unit (EA) Model / Breaking capacity at AC380/415V Rated current 3 pole Code Unit (EA) 125A UPB250H 3PMPS0000C 00125 8 125A UPB250L 3PMPS0000C 00125 8 150A UPB250H 3PMPS0000C 00150 8 150A UPB250L 3PMPS0000C 00150 8 175A UPB250H 3PMPS0000C 00175 8 175A UPB250L 3PMPS0000C 00175 8 200A UPB250H 3PMPS0000C 00200 8 200A UPB250L 3PMPS0000C 00200 8 225A UPB250H 3PMPS0000C 00225 8 225A UPB250L 3PMPS0000C 00225 8 UPB250L 130kA Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M4 Molded Case Circuit Breaker_ 115 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | Q-class (for nuclear power plant application) / HBL type 100AF | �HBL103U 85kA �HBL103UQ 85kA �HBL103UM 85kA �HBL103UMQ 85kA HBL103U HBL103UQ overload, inst., short-circuit 15,20,30,40,50,60,75,100 Rated impulse withstand voltage [Uimp] (kV) IEC 60947-2 K 60947-2 Trip mechanism & Protection characteristics Q-class Mounting AC660/690V, 50-60Hz AC480/500V, 50-60Hz AC440/460V, 50-60Hz Ultimate [Icu] AC380/415V, 50-60Hz (kA r.m.s.) AC220/240V, 50-60Hz DC250V DC125V Service [Ics] % of [Icu] Thermal magnetic 25 85 100 150 200 100 100 ○ - b d c 3P a b c d (6-7-8-9-10-11-12-13)×In ○ - ○ ○ ○ ○ ○ ○ ○ 25,000 10,000 105 165 86.5 112 1.8 Plug-in a instantaneous, short-circuit 2.5,3.2,6.3,12.5,20,32,50,63,80,100 AC750 AC690 DC500 8 25 25 85 85 100 100 150 150 200 200 100 100 100 100 100 ○ 10×In - Fixed thermal, Fixed instantaneous INST Adjustable instantaneous Non-E1 E1 Direct mounting by screw 25 85 100 150 200 100 100 Both line & load side for Switchboard Line side only Screw Terminal connection Bus bar Mechanical operation Durability (times) Electrical operation Dimensions (mm) HBL103UMQ 3 IP20 A ○ Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated short-circuit breaking capacity HBL103UM Width Height Depth Weight (kg, breaker only) 3P ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. ■ Accessories �Signal Auxiliary switch Trip alarm switch Shunt trip 1) Under voltage trip 2) 1ab, Right-hand-side AUX 12UP R1 1ab, Left-hand-side ALT 12UP L1 DC24V SHT 12UP A DC24V �UVT 12UP J DC100-110V SHT 12UP C DC100-110V �UVT 12UP L AC100-120V SHT 12UP F AC100-120V �UVT 12UP N ※ - Signal accessories shall be installed in breaker before ex-working. 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. 116 AC200-230V SHT 12UP H AC200-230V �UVT 12UP P AC380-415V SHT 12UP B AC380-415V �UVT 12UP Q AC440-480V SHT 12UP D AC440-480V �UVT 12UP R MCCB �Operating Power supply direction HBL103U, HBL103UM Operating Surface HBL103UQ, HBL103UMQ 1) handle HBL103U, HBL103UM Extended HBL103UQ, HBL103UMQ Upper TFG 20U U4 TFG 20UQ U4 Left TFG 20U L4 TFG 20UQ L4 TFH 20U TFH 20UQ DC24V MOT 12UP DC24 Motor operator 2) AC/DC110V MOT 12UP ADC110 MIF 12UP 3 PLD 12UP Mechanical interlock Padlock plate AC/DC220V MOT 12UP ADC220 ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting Plug-in Structure Mounting base Connection 6C contact block 1) 12C contact For both line & load side TDM 12NEP CBM 26NE 6 CBM 26NE 12 For line side only TDM 12NEF - ※ 1) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal Terminal bus bar Cage terminal block Terminal cover 1) Interpole barrier 2) 6EA/SET 3EA/SET TBB 12NE 3 CTB 12UP 3S TCF 12UP 3 TQQ 12NE 4EA/SET ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 4EA ■ Standard order code and unit �Fixed thermal & fixed instantaneous 40/45℃ Model / Breaking capacity at AC480/500V Rated current HBL103U 85kA 15A 20A 30A 40A 50A 60A 75A 100A 3 pole, Non-E1 class Code Unit (EA) HBL103U 3PT4S0000C 00015 HBL103U 3PT4S0000C 00020 HBL103U 3PT4S0000C 00030 HBL103U 3PT4S0000C 00040 HBL103U 3PT4S0000C 00050 HBL103U 3PT4S0000C 00060 HBL103U 3PT4S0000C 00075 HBL103U 3PT4S0000C 00100 8 8 8 8 8 8 8 8 Model / Breaking capacity at AC480/500V Rated current HBL103UQ 85kA 15A 20A 30A 40A 50A 60A 75A 100A Model / Breaking capacity at AC480/500V Rated current HBL103UQ 85kA 15A 20A 30A 40A 50A 60A 75A 100A 3 pole, E1 class Code Unit (EA) HBL103UQ 3PT4S0000C 00015 HBL103UQ 3PT4S0000C 00020 HBL103UQ 3PT4S0000C 00030 HBL103UQ 3PT4S0000C 00040 HBL103UQ 3PT4S0000C 00050 HBL103UQ 3PT4S0000C 00060 HBL103UQ 3PT4S0000C 00075 HBL103UQ 3PT4S0000C 00100 8 8 8 8 8 8 8 8 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M1 50℃ Model / Breaking capacity at AC480/500V Rated current HBL103U 85kA 15A 20A 30A 40A 50A 60A 75A 100A 3 pole, Non-E1 class Code Unit (EA) HBL103U 3PT5S0000C 00015 HBL103U 3PT5S0000C 00020 HBL103U 3PT5S0000C 00030 HBL103U 3PT5S0000C 00040 HBL103U 3PT5S0000C 00050 HBL103U 3PT5S0000C 00060 HBL103U 3PT5S0000C 00075 HBL103U 3PT5S0000C 00100 8 8 8 8 8 8 8 8 3 pole, E1 class Code Unit (EA) HBL103UQ 3PT5S0000C 00015 HBL103UQ 3PT5S0000C 00020 HBL103UQ 3PT5S0000C 00030 HBL103UQ 3PT5S0000C 00040 HBL103UQ 3PT5S0000C 00050 HBL103UQ 3PT5S0000C 00060 HBL103UQ 3PT5S0000C 00075 HBL103UQ 3PT5S0000C 00100 8 8 8 8 8 8 8 8 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M1 �Adjustable instantaneous only / recommended for motor protection Model / Breaking capacity at AC480/500V Rated current HBL103UM 85kA 2.5A 3.2A 6.3A 12.5A 20A 32A 50A 63A 80A 100A 3 pole, Non-E1 class Code HBL103UM 3PMPS0000C 002.5 HBL103UM 3PMPS0000C 003.2 HBL103UM 3PMPS0000C 006.3 HBL103UM 3PMPS0000C 012.5 HBL103UM 3PMPS0000C 00020 HBL103UM 3PMPS0000C 00032 HBL103UM 3PMPS0000C 00050 HBL103UM 3PMPS0000C 00063 HBL103UM 3PMPS0000C 00080 HBL103UM 3PMPS0000C 00100 Unit (EA) 8 8 8 8 8 8 8 8 8 8 Model / Breaking capacity at AC480/500V Rated current HBL103UMQ 85kA 2.5A 3.2A 6.3A 12.5A 20A 32A 50A 63A 80A 100A 3 pole, E1 class Code Unit (EA) HBL103UMQ 3PMPS0000C 002.5 HBL103UMQ 3PMPS0000C 003.2 HBL103UMQ 3PMPS0000C 006.3 HBL103UMQ 3PMPS0000C 012.5 HBL103UMQ 3PMPS0000C 00020 HBL103UMQ 3PMPS0000C 00032 HBL103UMQ 3PMPS0000C 00050 HBL103UMQ 3PMPS0000C 00063 HBL103UMQ 3PMPS0000C 00080 HBL103UMQ 3PMPS0000C 00100 8 8 8 8 8 8 8 8 8 8 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M4 Molded Case Circuit Breaker_ 117 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | Q-class (for nuclear power plant application) / HBL type 225AF | �HBL203U 85kA �HBL203UQ 85kA �HBL203UM 85kA �HBL203UMQ 85kA HBL203U HBL203UQ HBL203UM HBL203UMQ 3 IP20 A ○ Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) AC660/690V, 50-60Hz Rated AC480/500V, 50-60Hz short-circuit Ultimate AC440/460V, 50-60Hz breaking [Icu] AC380/415V, 50-60Hz capacity (kA r.m.s.) AC220/240V, 50-60Hz DC250V IEC 60947-2 DC125V K 60947-2 Service [Ics] % of [Icu] Fixed thermal, Trip mechanism Thermal & Protection magnetic Fixed instantaneous INST characteristics Adjustable instantaneous Non-E1 Q-class E1 Direct mounting by screw Mounting Both line & load side for Plug-in Switchboard Line side only Screw Terminal connection Bus bar Mechanical operation Durability (times) Electrical operation d a a Width c b Height Dimensions 3P b (mm) c Depth d Weight (kg, breaker only) 3P overload, inst., short-circuit instantaneous, short-circuit 125,150,175,200,225 AC750 AC690 DC500 8 25 25 25 25 85 85 85 85 100 100 100 100 150 150 150 150 200 200 200 200 100 100 100 100 100 100 100 100 100 ○ 10×In (6-7-8-9-10-11-12-13)×In ○ ○ ○ ○ ○ ○ ○ ○ ○ 25,000 10,000 105 165 86.5 112 2.0 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. ■ Accessories �Signal Auxiliary switch Trip alarm switch Shunt trip 1) Under voltage trip 2) 1ab, Right-hand-side AUX 12UP R1 1ab, Left-hand-side ALT 12UP L1 DC24V SHT 12UP A DC24V �UVT 12UP J DC100-110V SHT 12UP C DC100-110V �UVT 12UP L AC100-120V SHT 12UP F AC100-120V �UVT 12UP N ※ - Signal accessories shall be installed in breaker before ex-working. 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. 118 AC200-230V SHT 12UP H AC200-230V �UVT 12UP P AC380-415V SHT 12UP B AC380-415V �UVT 12UP Q AC440-480V SHT 12UP D AC440-480V �UVT 12UP R MCCB �Operating Power supply direction HBL203U, HBL203UM Operating Surface HBL203UQ, HBL203UMQ 1) handle HBL203U, HBL203UM Extended HBL203UQ, HBL203UMQ Upper TFG 20U U4 TFG 20UQ U4 Left TFG 20U L4 TFG 20UQ L4 TFH 20U TFH 20UQ DC24V MOT 12UP DC24 Motor operator 2) AC/DC110V MOT 12UP ADC110 MIF 12UP 3 PLD 12UP Mechanical interlock Padlock plate AC/DC220V MOT 12UP ADC220 ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting Plug-in Structure Mounting base Connection 6C contact block 1) 12C contact For both line & load side TDM 12NEP CBM 26NE 6 CBM 26NE 12 For line side only TDM 12NEF - ※ 1) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal Terminal bus bar Cage terminal block Terminal cover 1) Interpole barrier 2) 6EA/SET 3EA/SET TBB 12NE 3 CTB 12UP 3S TCF 12UP 3 TQQ 12NE 4EA/SET ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 4EA ■ Standard order code and unit �Fixed thermal & fixed instantaneous 40/45℃ Model / Rated Breaking capacity at current AC480/500V HBL203U 85kA 125A 150A 175A 200A 225A 3 pole, Non-E1 class Code HBL203U 3PT4S0000C 00125 HBL203U 3PT4S0000C 00150 HBL203U 3PT4S0000C 00175 HBL203U 3PT4S0000C 00200 HBL203U 3PT4S0000C 00225 Model / Unit Breaking capacity at AC480/500V (EA) 8 8 8 8 8 HBL203UQ 85kA Rated current 125A 150A 175A 200A 225A 3 pole, E1 class Code Unit (EA) HBL203UQ 3PT4S0000C 00125 HBL203UQ 3PT4S0000C 00150 HBL203UQ 3PT4S0000C 00175 HBL203UQ 3PT4S0000C 00200 HBL203UQ 3PT4S0000C 00225 8 8 8 8 8 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M1 50℃ Model / Rated Breaking capacity at current AC480/500V HBL203U 85kA 125A 150A 175A 200A 225A 3 pole, Non-E1 class Code HBL203U 3PT5S0000C 00125 HBL203U 3PT5S0000C 00150 HBL203U 3PT5S0000C 00175 HBL203U 3PT5S0000C 00200 HBL203U 3PT5S0000C 00225 Model / Unit Breaking capacity at AC480/500V (EA) 8 8 8 8 8 HBL203UQ 85kA Rated current 125A 150A 175A 200A 225A 3 pole, E1 class Code Unit (EA) HBL203UQ 3PT5S0000C 00125 HBL203UQ 3PT5S0000C 00150 HBL203UQ 3PT5S0000C 00175 HBL203UQ 3PT5S0000C 00200 HBL203UQ 3PT5S0000C 00225 8 8 8 8 8 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M1 �Adjustable instantaneous only / recommended for motor protection Model / Rated Breaking capacity at current AC480/500V HBL203UM 85kA 125A 150A 175A 200A 225A 3 pole, Non-E1 class Code HBL203UM 3PMPS0000C 00125 HBL203UM 3PMPS0000C 00150 HBL203UM 3PMPS0000C 00175 HBL203UM 3PMPS0000C 00200 HBL203UM 3PMPS0000C 00225 Model / Unit Breaking capacity at AC480/500V (EA) 8 8 8 8 8 HBL203UMQ 85kA Rated current 125A 150A 175A 200A 225A 3 pole, E1 class Code Unit (EA) HBL203UMQ 3PMPS0000C 00125 HBL203UMQ 3PMPS0000C 00150 HBL203UMQ 3PMPS0000C 00175 HBL203UMQ 3PMPS0000C 00200 HBL203UMQ 3PMPS0000C 00225 8 8 8 8 8 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M4 Molded Case Circuit Breaker_ 119 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | Switch disconnector / UAD type 50-100AF | �UAD50C �UAD50S �UAD100R UAD50C Ampere frame size Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Conventional thermal current [Ith] (A) Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit making capacity [Icm] (kA peak at AC460V) Rated short-time withstand current for 1sec. [Icw] (kA r.m.s) Mechanical operation Durability (times) Electrical operation Direct mounting by screw Both line & load side for Switchboard Line side only Mounting Plug-in for Distribution board DIN-rail with DIN-rail adaptor Terminal connection Screw d a a Width c b Height Dimensions 3P b (mm) c Depth d Weight (kg, breaker only) 3P UAD50S 50AF UAD100R 3 IP20 A ○ 3 IP20 A ○ 100AF 3 IP20 A ○ 50 50 AC690 AC660 DC250 6 17 1 25,000 15,000 ○ ○ ○ ○ ○ 50 50 AC690 AC660 DC250 6 52.5 1 25,000 15,000 ○ ○ ○ ○ ○ ○ 100 100 AC690 AC660 DC250 6 52.5 1 25,000 10,000 ○ ○ ○ ○ ○ ○ 75 130 60 82 0.65 75 130 60 82 0.78 75 130 60 82 0.78 ■ Accessories �Signal Auxiliary switch UAD50C UAD50S, UAD100R Trip alarm switch UAD50C UAD50S, UAD100R Shunt trip 1) UAD50C UAD50S, UAD100R Under voltage trip2) UAD50C UAD50S, UAD100R 1ab, Right-hand-side 1ab, Left-hand-side 2ab,Right-hand-side AUX 10A R1 AUX 10A R2 AUX 10UA R1 AUX 10UA L1 1ab, Right-hand-side 1ab, Left-hand-side ALT 10A R1 ALT 10UA R1 ALT 10UA L1 DC24V DC100-110V AC100-120V SHT 10A A SHT 10A C SHT 10A F SHT 10UA A SHT 10UA C SHT 10UA F DC24V DC100-110V AC100-120V �UVT 10A J �UVT 10A L �UVT 10A N UVT 10UA J UVT 10UA L UVT 10UA N ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. 120 AC200-230V SHT 10UA H AC200-230V �UVT 10A P UVT 10UA P AC380-415V SHT 10A H SHT 10UA B AC380-415V �UVT 10A Q UVT 10UA Q AC440-480V SHT 10UA D AC440-480V �UVT 10A R UVT 10UA R MCCB �Operating UAD50C Power supply direction S type Operating Surface L type handle 1) S type Extended L type Motor operator 2) UAD50S, UAD100R Upper Right Left Upper Right Left TFG 10AS U4 TFG 10AS R4 TFG 10AS L4 TFG 10UAS U4 TFG 10UAS R4 TFG 10UAS L4 - TFG 10AL L4 TFG 10UAL U4 - TFG 10UAL L4 TFG 10AL U4 TFH 10AS TFH 10UAS TFH 10AL TFH 10UAL DC24V AC/DC110V AC/DC220V DC24V AC/DC110V AC/DC220V MOT 10A DC24 MOT 10A ADC110 MOT 10A ADC220 MOT 10UA DC24 MOT 10UA ADC110 MOT 10UA ADC220 Mechanical interlock MIF 10A 3 MIF 10UA 3 ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting DIN-rail adaptor 1) Structure Mounting base Plug-in Connection 2C contact block 2) 3C contact Conn block barrier DRA 10UA For both line & load side TDM 10AP CBM 10AB 2 CBM 10AB 3 CBM BARR For line side only TDF 10A - ※ 1) Available for UAD50S, UAD100R 2) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal Cage terminal block 3EA/SET CTB 10A 3S Terminal cover 1) Interpole barrier 2) TCF 10AP 3 2EA/SET TQQ 10A ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 4EA ■ Standard order code and unit 3 pole Rated current Code Unit (EA) UAD50C 50A UAD50C 3PDS0000C 00050 20 UAB50C UAD50S 50A UAD50S 3PDS0000C 00050 20 UAB50S UAD100R 100A UAD100R 3PDS0000C 00100 20 UAB100R Model Originated MCCB model Specification Category Screw type terminal connection, No option, 50/60Hz MCCB/M5 Molded Case Circuit Breaker_ 121 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | Switch disconnector / UCD type 50-250AF | �UCD50H �UCD100H �UCD250S �UCD100S �UCD160H �UCD250H Ampere frame size Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Conventional thermal current [Ith] (A) Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit making capacity [Icm] (kA peak at AC460V) Rated short-time withstand current for 1sec. [Icw](kA r.m.s.) Mechanical operation Durability (times) Electrical operation Direct mounting by screw Both line & load side for Mounting Switchboard Line side only Plug-in for Distribution board Screw Terminal connection Bus bar a Width d a c b Height Dimensions 3P b (mm) c Depth d Weight (kg, breaker only) 3P UCD50H UCD100S UCD100H UCD160H UCD250S UCD250H 50AF 3 IP20 A ○ 100AF 3 IP20 A ○ 125AF 3 IP20 A ○ 160AF 3 IP20 A ○ 3 IP20 A ○ 3 IP20 A ○ 50 AC690 AC660 DC250 6 105 1 25,000 10,000 ○ ○ ○ ○ ○ 100 AC690 AC660 DC250 6 73.5 1 25,000 10,000 ○ ○ ○ ○ ○ 125 AC690 AC660 DC250 6 105 1 25,000 10,000 ○ ○ ○ ○ ○ - - - 160 AC690 AC660 DC250 6 105 2 25,000 10,000 ○ ○ ○ ○ ○ ○ 250 AC690 AC660 DC250 6 73.5 2 25,000 10,000 ○ ○ ○ ○ ○ ○ 250 AC690 AC660 DC250 6 105 2 25,000 10,000 ○ ○ ○ ○ ○ ○ 90 155 60 84.5 1 90 155 60 84.5 1 90 155 60 84.5 1 105 165 60 84.5 1.3 105 164 60 84 1.2 105 165 60 84.5 1.3 250AF ■ Accessories �Signal Auxiliary switch 1ab, Right-hand-side 1ab, Left-hand-side 2ab, Right-hand-side UCD100S - AUX 10B L1 - AUX 12FG R1 - UCD250S UCD50H, UCD100H, UCD160H, UCD250H AUX 20C L1 AUX 12FG R2 Trip alarm switch 1ab, Right-hand-side 1ab, Left-hand-side UCD100S - ALT 10B L1 UCD250S UCD50H, UCD100H, UCD160H, UCD250H Shunt trip 1) UCD100S ALT 20C L ALT 12FG R1 DC24V DC100-110V SHT 10B A SHT 10B C AC100-120V ALT 12FG L1 AC200-230V AC380-415V SHT 10B F UCD250S SHT 20C A SHT 20C C SHT 20C F UCD50H, UCD100H, UCD160H, UCD250H SHT 12FG A SHT 12FG C SHT 12FG F SHT 12FG H SHT 12FG B SHT 12FG D DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V UCD100S UVT 10B J UVT 10B L UVT 10B N UVT 10B P UVT 10B Q UVT 10B R UCD250S UVT 20C J UVT 20C L UVT 20C N UVT 20C P UVT 20C Q UVT 20C R UCD50H, UCD100H, UCD160H, UCD250H UVT 12FG J UVT 12FG L UVT 12FG N UVT 12FG P UVT 12FG Q UVT 12FG R Under voltage trip 2) SHT 20C H ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) 122 AC440-480V SHT 10B H MCCB �Operating UCD50H, UDC100H Power supply direction S type Operating Surface L type handle 1) S type Extended L type Motor operator 2) UCD100S Upper Right Left Upper Right Left TFG 10UFS U4 TFG 10UFS R4 TFG 10UFS L4 TFG 10BS U4 TFG 10BS R4 TFG 10BS L4 - TFG 10UFL L4 TFG 10BL U4 - TFG 10BL L4 TFG 10UFL U4 TFH 10UFS TFH 10BS TFH 10UFL TFH 10BL DC24V AC/DC110V AC/DC220V DC24V AC/DC110V AC/DC220V MOT 10F DC24 MOT 10F ADC110 MOT 10F ADC220 MOT 10B DC24 MOT 10B ADC110 MOT 10B ADC220 MIF 10UF 3 Mechanical interlock MIF 10UF 3 UCD250S Power supply direction S type Operating Surface L type handle 1) S type Extended L type Motor operator 2) UCD160H, UCD250H Upper Right Left Upper Right Left TFG 20CS U4 TFG 20CS R4 TFG 20CS L4 TFG 20UGS U4 TFG 20UGS R4 TFG 20UGS L4 - TFG 20CL L4 TFG 20UGL U4 - TFG 20UGL L4 TFG 20CL U4 TFH 20CS TFH 20UGS TFH 20CL TFH 20UGL DC24V AC/DC110V AC/DC220V DC24V AC/DC110V AC/DC220V MOT 20C DC24 MOT 20C ADC110 MOT 20C ADC220 MOT 20G DC24 MOT 20G ADC110 MOT 20G ADC220 Mechanical interlock MIF 20UG 3 MIF 20UG 3 ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. �Mounting UCD50H, UCD100S, UCD100H Structure For both line & load side For line side only Mounting base TDM 10BP TDF 10B Plug-in Connection 2C contact CBM 10AB 2 block 1) 3C/5C contact CBM 10AB 3 3) Conn. block barrier CBM BARR - UCD160H, UCD250S, UCD250H For both line & load side For line side only TDM 20CF 2) CBM 20C 2 CBM 20C 5 3) - TDM 20CF - ※ 1) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. 2) 2EA are required for both line & load side plug-in type 3P breaker. 3) CBM 10AB 3: 3C, CBM 20C 5: 5C �Terminal Terminal bus bar Cage terminal block 3EA/SET Terminal cover 1) Interpole barrier 2) 2EA/SET UCD100S UCD50H, UCD100H - - UCD250S UCD160H, UCD250H TBB 20C 3 CTB 10B 3S CTB 20C 3S TCF 10BP 3 TCF 10FP 3 TCF 20CP 3 TCF 20GP 3 TQQ 10B TQQ 12FG TQQ 20C TQQ 12FG ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 4EA ■ Standard order code and unit 3 pole Originated MCCB model Rated current Code UCD50H 50A UCD50H 3PDS0000C 00050 8 UCB50H UCD100S 100A UCD100S 3PDS0000C 00100 10 UCB100S UCD100H 125A UCD100H 3PDS0000C 00125 8 UCB100H UCD160H 160A UCD160H 3PDS0000C 00160 8 UCB160H UCD250S 250A UCD250S 3PDS0000C 00250 10 UCB250S UCD250H 250A UCD250H 3PDS0000C 00250 8 UCB250H Model Unit (EA) Specification Category Screw type terminal connection, No option, 50/60Hz MCCB/M5 Molded Case Circuit Breaker_ 123 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | Switch disconnector / UCD type 400-1250AF | �UCD400S �UCD630S �UCD800S �UCD1000S �UCD1250S Ampere frame size Number of poles (P) Degree of protection (with terminal cover) Utilization category Suitability of isolation Conventional thermal current [Ith] (A) Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit making capacity [Icm] (kA peak at AC460V) Rated short-time withstand current for 1sec. [Icw](kA r.m.s.) Mechanical operation Durability (times) Electrical operation Direct mounting by screw Mounting Both line & load side for Plug-in Switchboard Line side only Screw Terminal connection Bus bar a Width d a c Dimensions (mm) b 3P Weight (kg, breaker only) 3P b c d Height Depth UCD400S UCD630S UCD800S UCD1000S UCD1250S 400AF 3 IP20 A ○ 400 400 AC690 AC660 DC250 6 187 4 20,000 6,000 ○ ○ ○ ○ ○ 140 257 110 145 4.5 630AF 3 IP20 A ○ 630 630 AC690 AC660 DC250 6 187 6.3 20,000 6,000 ○ ○ ○ ○ ○ 210 280 110 145 9.5 800AF 3 IP20 A ○ 800 800 AC690 AC660 DC250 6 187 8 10,000 3,000 ○ ○ ○ ○ ○ 210 280 110 145 9.5 1000AF 3 IP20 1) A ○ 1,000 1,000 AC750 AC690 1250AF 3 IP20 1) A ○ 1,250 1,250 AC750 AC690 - - 8 165 10 10,000 3,000 8 165 12.5 10,000 3,000 - - - - - - - - ○ 210 370 110 159 13 ○ 210 370 110 159 13.5 ※ 1) IP20 without terminal bus bar ■ Accessories �Signal Auxiliary switch 1ab, Left-hand-side 1ab, Right-hand-side 2ab, Right-hand-side 3ab, Right-hand-side UCD400, UCD630, UCD800 AUX 46D L1 UCD1000, UCD1250 AUX 80NE R1 AUX 80NE R2 AUX 80NE R3 1ab, Left-hand-side 1ab, Right-hand-side Trip alarm switch ALT 46D L1 UCD400, UCD630, UCD800 ALT 80NE R1 UCD1000, UCD1250 Shunt trip 1) DC24V DC100-110V AC100-120V AC200-230V SHT 46D A SHT 46D C SHT 46D F SHT 46D H UCD400, UCD630, UCD800 SHT 120NE A SHT 120NE C SHT 120NE F SHT 120NE H UCD1000, UCD1250 DC24V DC100-110V AC100-120V AC200-230V Under voltage trip 2) �UVT 46D J �UVT 46D L �UVT 46D N �UVT 46D P UCD400, UCD630,UCD800 UVT 120NE J UVT 120NE L UVT 120NE N UVT 120NE P UCD1000, UCD1250 ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. 124 AC380-415V SHT 46D B SHT 120NE B AC380-415V �UVT 46D Q UVT 120NE Q AC440-480V SHT 46D D SHT 120NE D AC440-480V �UVT 46D R UVT 120NE R MCCB �Operating UCD400, UCD630, UCD800 Power supply direction Operating Surface S type handle 1) Extended S type Upper Right Left TFG 46DS U2 TFG 46DS R2 TFG 46DS L2 TFH 46DS UCD400 DC24V Motor operator 2) UCD630, UCD800 AC/DC110V AC/DC220V DC24V AC/DC110V MOT 40D DC24 MOT 40D ADC110 MOT 40D ADC220 MOT 68E DC24 Mechanical interlock UCD1000, UCD1250 AC/DC220V DC24V AC/DC110V MIF 40D 3 - MIF 80E 3 Extension handle 3) AC/DC220V MOT 68E ADC110 MOT 68E ADC220 MOT 80NE DC24 MOT 80NE ADC110 MOT 80NE ADC220 THA 46D THA 80NE ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. 3) Supplied as standard component �Mounting UCD400 Structure Mounting base Plug-in Connection 2C contact 5C contact block 1) For both line & load side TDM 4BA 2) TYA 5/2 3) TYA 5/5 3) UCD630, UCD800 For line side only For both line & load side For line side only TDM 4BA - TDM 5BA 2) TYA 5/2 3) TYA 5/5 3) TDM 5BA - ※ 1) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. 2) 2EA are required for both line & load side plug-in type 3P breaker. 3) TYA type connection blocks are to be installed with separate mounting angle. Separate mounting angle is not supplied. �Terminal Terminal bus bar Cage terminal block 3EA/SET Terminal cover 1) Interpole barrier 2) 2EA/SET UCD400 UCD630 UCD800 TBB 4S 3 TBB 6S 3 TBB 8S 3 UCD1000, UCD1250 - CTB 40D 3S CTB 80E 3S TCF 40D 3 TCF 80E 3 - TQQ 4BA TQQ 5BA TQQ 80NE ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 4EA ■ Standard order code and unit 3 pole Originated MCCB model Model Rated current Code Unit (EA) UCD400S 400A UCD400S 3PDS0000C 00400 3 UCB400S UCD630S 630A UCD630S 3PDS0000C 00630 2 UCB630S UCD800S 800A UCD800S 3PDS0000C 00800 2 UCB800S UCD1000S 1000A UCD1000S 3PDB0000C 01000 1 UCB1000S UCD1250S 1250A UCD1250S 3PDB0000C 01250 1 UCB1250S Specification Screw type terminal connection, No option, 50/60Hz Category MCCB/M5 Bus bar type terminal connection, No option, 50/60Hz Molded Case Circuit Breaker_ 125 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | Switch disconnector / UPD type 125-630AF | �UPD100S �UPD160S �UPD250S �UPD400S �UPD630S UPD100S UPD160S UPD250S UPD400S UPD630S Ampere frame size 125AF 160AF 250AF 400AF 630AF Number of poles (P) 3 3 3 3 3 IP20 IP20 IP20 IP20 IP20 Utilization category A A A A A Suitability of isolation ○ ○ ○ ○ ○ Conventional thermal current [Ith] (A) 125 160 250 400 630 Rated current (A) 125 160 250 400 630 AC750 AC750 AC750 AC750 AC750 AC690 AC690 AC690 AC690 AC690 DC500 DC500 DC500 - - 8 8 8 8 8 200 200 200 200 200 Degree of protection (with terminal cover) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit making capacity [Icm] (kA peak at AC460V) 1 1.6 2.5 4 6.3 25,000 25,000 25,000 20,000 20,000 10,000 10,000 10,000 6,000 6,000 Rated short-time withstand current for 1sec. [Icw](kA r.m.s) Durability Mechanical operation (times) Electrical operation ○ ○ ○ ○ ○ Both line & load side for Switchboard Line side only ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Screw ○ ○ ○ ○ ○ Direct mounting by screw Mounting Plug-in Terminal connection a Dimensions (mm) b ○ ○ ○ ○ ○ a Width 105 105 105 140 140 b Height 165 165 165 255 255 c Depth 86.5 86.5 86.5 117 117 112 112 112 159.5 159.5 1.8 2 2 6 6 Bus bar d c 3P d Weight (kg, breaker only) 3P ■ Accessories �Signal Auxiliary switch 1ab, Right-hand-side 1ab, Left-hand-side UPD100, UPD160,UPD250 AUX 12UP R1 UPD400, UPD630 AUX 46UP L1 1ab, Right-hand-side 1ab, Left-hand-side Trip alarm switch ALT 12UP L1 UPD100, UPD160,UPD250 ALT 46UP R1 UPD400, UPD630 DC24V DC100-110V Shunt trip 1) SHT 12UP A SHT 12UP C UPD100, UPD160,UPD250 UPD400, UPD630 SHT 46UP A SHT 46UP C Under voltage trip 2) DC24V DC100-110V �UVT 12UP J �UVT 12UP L UPD100, UPD160,UPD250 �UVT 46UP J �UVT 46UP L UPD400, UPD630 AC100-120V SHT 12UP F SHT 46UP F AC100-120V �UVT 12UP N �UVT 46UP N ※ 1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC 2) The permissible operating voltage: 85-110% of rated voltage(AC), 85~125% of rated voltage(DC) The tripping voltage: 20-70% of rated voltage(AC/DC) �Reset is possible without power. 126 AC200-230V SHT 12UP H SHT 46UP H AC200-230V �UVT 12UP P �UVT 46UP P AC380-415V SHT 12UP B SHT 46UP B AC380-415V �UVT 12UP Q �UVT 46UP Q AC440-480V SHT 12UP D SHT 46UP D AC440-480V �UVT 12UP R �UVT 46UP R MCCB �Operating UPD100, UPD160, UPD250 Power supply direction S type Operating Surface L type handle 1) S type Extended L type Right Left Upper Right Left TFG 12UPS U4 TFG 12UPS R4 TFG 12UPS L4 TFG 46UPS U2 TFG 46UPS R2 TFG 46UPS L2 - TFG 12UPL L4 - - - TFG 12UPL U4 TFH 12UPS TFH 46UPS - TFH 12UPL DC24V Motor operator 2) UPD400, UPD630 Upper AC/DC110V MOT 12UP DC24 AC/DC220V DC24V MOT 12UP ADC110 MOT 12UP ADC220 AC/DC110V MOT 46UP DC24 Mechanical interlock MIF 12UP 3 MIF 46UP 3 Padlock plate PLD 12UP PLD 12UP - THA 46UP Extension handle 3) AC/DC220V MOT 46UP ADC110 MOT 46UP ADC220 ※ 1) For detail type information, please refer to page 201-209. 2) Motor operator is not recommended for marine application. 3) Supplied as standard component �Mounting UPD100, UPD160, UPD250 Structure Plug-in UPD400, UPD630 For both line & load side For line side only For both line & load side For line side only Mounting base TDM 12NEP TDM 12NEF TDM 46NEP TDM 46NEF Connection 6C contact block 1) 12C contact CBM 26NE 6 - CBM 26NE 6 - CBM 26NE 12 - CBM 26NE 12 - ※ 1) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. �Terminal UPD100, UPD160, UPD250 UPD400 UPD630 6EA/SET TBB 12NE 3 TBB 40NE 3 TBB 60NE 3 Cage terminal block 3EA/SET CTB 12UP 3S CTB 46UP 3S Terminal cover 1) TCF 12UP 3 TCF 46UP 3 TQQ 12NE TQQ 46NE Terminal bus bar Interpole barrier 2) 4EA/SET ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 4EA ■ Standard order code and unit 3 pole Originated MCCB model Model Rated current UPD100S 125A UPD100S 3PDS0000C 00125 8 UPB100S UPD160S 160A UPD160S 3PDS0000C 00160 8 UPB160S UPD250S 250A UPD250S 3PDS0000C 00250 8 UPB250S UPD400S 400A UPD400S 3PDS0000C 00400 3 UPB400S UPD630S 630A UPD630S 3PDS0000C 00630 3 UPB630S Code Unit (EA) Specification Category Screw type terminal connection, No option, 50/60Hz MCCB/M5 Molded Case Circuit Breaker_ 127 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | Miniature type / Molded case circuit breaker UBD type 30AF | �UBD30L 5kA �UBD30H 5kA UBD30L UBD30H 30AF Ampere frame size Number of poles (P) 2 Degree of protection IP20 Utilization category A overload, short-circuit Protection 15,20,30 Rated current (A) Rating Rated insulation voltage [Ui] (V) AC250 Rated operational voltage [Ue] (V) AC220 6 Rated impulse withstand voltage [Uimp] (kV) Rated Ultimate [Icu] AC220/240V, 50-60Hz short-circuit (kA r.m.s.) breaking capacity 5 IEC 60947-2 K 60947-2 50 Service [Ics] % of [Icu] ○ Trip mechanism Thermal magnetic Mounting a ○ - DIN-rail Terminal connection Dimensions (mm) ○ Direct mounting by screw ○ Screw d c 2P b a Width 35 b Height 82.5 c Depth 42 d Weight (kg, breaker only) 2P 60 54.6 76 0.12 0.14 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. ■ Standard order code and unit 40/45℃ Model / Breaking capacity at AC220/240V Rated current 15A 2 pole Code Unit (EA) UBD30H 5kA 20A 30A UBD30L 2PT4S0000C 00015 UBD30L 2PT4S0000C 00020 UBD30L 2PT4S0000C 00030 UBD30H 2PT4S0000C 00015 UBD30H 2PT4S0000C 00020 UBD30H 2PT4S0000C 00030 Model / Breaking capacity at AC220/240V Rated current Code Unit (EA) UBD30L 2PT5S0000C 00015 UBD30L 2PT5S0000C 00020 UBD30L 2PT5S0000C 00030 UBD30H 2PT5S0000C 00015 UBD30H 2PT5S0000C 00020 UBD30H 2PT5S0000C 00030 100 100 100 100 100 100 UBD30L 5kA 20A 30A 15A 100 100 100 100 100 100 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB/M1 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB/M1 50℃ 15A UBD30L 5kA 20A 30A 15A UBD30H 5kA 128 20A 30A 2 pole MCCB | Miniature type / Molded case circuit breaker UMB type 30-50AF | �UMB30R 2.5kA �UMB30S 5kA �UMB50S 5kA UMB30R UMB30S UMB30H UMB50S UMB50H �UMB30H 10kA �UMB50H 10kA Ampere frame size Number of poles (P) Degree of protection Utilization category Protection Rated current (A) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Rated Ultimate [Icu] AC220/240V, 50-60Hz short-circuit (kA r.m.s.) breaking capacity IEC 60947-2 Service [Ics] % of [Icu] K 60947-2 Hydraulic magnetic Trip mechanism Thermal magnetic Direct mounting by screw Mounting DIN-rail Terminal connection Screw d a a Width c Dimensions b Height 2P b (mm) c Depth d Weight (kg, breaker only) 2P 30AF 2 IP20 A overload, short-circuit 15, 20, 30 AC250 AC220 6 2.5 5 50AF 2 IP20 A overload, short-circuit 15, 20, 30, 40, 50 AC250 AC220 6 10 5 ○ - ○ 50 ○ 50 ○ ○ ○ ○ ○ - ○ ○ 33 70 42 57 0.1 10 ○ 35 80 60 76 0.15 35 80 60 76 0.13 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. ■ Standard order code and unit 40/45℃ Model / Breaking capacity at AC220/240V UMB30R 2.5kA UMB30S 5kA UMB30H 10kA UMB50S 5kA UMB50H 10kA Rated current 15A 20A 30A 15A 20A 30A 15A 20A 30A 15A 20A 30A 40A 50A 15A 20A 30A 40A 50A 2 pole Code UMB30R 2PT4S0000C 00015 UMB30R 2PT4S0000C 00020 UMB30R 2PT4S0000C 00030 UMB30S 2PT4S0000C 00015 UMB30S 2PT4S0000C 00020 UMB30S 2PT4S0000C 00030 UMB30H 2PT4S0000C 00015 UMB30H 2PT4S0000C 00020 UMB30H 2PT4S0000C 00030 UMB50S 2PT4S0000C 00015 UMB50S 2PT4S0000C 00020 UMB50S 2PT4S0000C 00030 UMB50S 2PT4S0000C 00040 UMB50S 2PT4S0000C 00050 UMB50H 2PT4S0000C 00015 UMB50H 2PT4S0000C 00020 UMB50H 2PT4S0000C 00030 UMB50H 2PT4S0000C 00040 UMB50H 2PT4S0000C 00050 Unit(EA) 150 150 150 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 Rated current 15A 20A 30A 15A 20A 30A 15A 20A 30A 15A 20A 30A 40A 50A 15A 20A 30A 40A 50A 2 pole Code UMB30R 2PT5S0000C 00015 UMB30R 2PT5S0000C 00020 UMB30R 2PT5S0000C 00030 UMB30S 2PT5S0000C 00015 UMB30S 2PT5S0000C 00020 UMB30S 2PT5S0000C 00030 UMB30H 2PT5S0000C 00015 UMB30H 2PT5S0000C 00020 UMB30H 2PT5S0000C 00030 UMB50S 2PT5S0000C 00015 UMB50S 2PT5S0000C 00020 UMB50S 2PT5S0000C 00030 UMB50S 2PT5S0000C 00040 UMB50S 2PT5S0000C 00050 UMB50H 2PT5S0000C 00015 UMB50H 2PT5S0000C 00020 UMB50H 2PT5S0000C 00030 UMB50H 2PT5S0000C 00040 UMB50H 2PT5S0000C 00050 Unit(EA) 150 150 150 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB/M1 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB/M1 50℃ Model / Breaking capacity at AC220/240V UMB30R 2.5kA UMB30S 5kA UMB30H 10kA UMB50S 5kA UMB50H 10kA Molded Case Circuit Breaker_ 129 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | Miniature type / Molded case circuit breaker UDB type 30-100AF | �UDB30S 5kA �UDB50S 5kA �UDB100S 5kA �UDB30H 10kA �UDB50H 10kA �UDB100H 10kA UDB30S UDB30H UDB50S UDB50H UDB100S UDB100H Ampere frame size 30AF 50AF 100AF Number of poles (P) 2, 3 2, 3 �2, 3 Degree of protection IP20 IP20 IP20 Utilization category A A overload, short-circuit Protection Rated current (A) Rated operational voltage [Ue] (V) 5,10,15,20,30,40,50 AC460 AC460 AC460 2P: AC220 2P: AC220 2P: AC220 3P: AC220/460 3P: AC220/460 3P: AC220/460 6 6 6 Rated impulse withstand voltage [Uimp] (kV) Rated short-circuit Ultimate breaking capacity [Icu] (kA r.m.s.) IEC 60947-2 K 60947-2 Service [Ics] Trip mechanism Terminal connection 2.5 AC380/415V, 50-60Hz 2.5 AC220/240V, 50-60Hz 5 15-30A: 5 5-10A: 2.5 15-30A: 5 5-10A: 5 15-30A: 10 % of [Icu] 15-50A: 5 5-10A: 2.5 2.5 15-50A: 5 5-10A: 5 5 15-50A: 10 2.5 5 2.5 5 5 10 50 ○ Direct mounting by screw ○ ○ ○ DIN-rail ○ ○ ○ Screw ○ ○ ○ a Width 50/75 50/75 75 2) /75 b Height 96 96 96 c Depth 60 60 60 80 80 80 0.2/0.35 0.2/0.35 0.2/0.35 d Weight (kg, breaker only) 2.5 50 ○ 2/3P b 5-10A: 2.5 15,20,30,40,50,60,75,100 50 ○ d c a Dimensions (mm) AC440/460V, 50-60Hz 5-10A: 2.5 Hydraulic magnetic Mounting overload, short-circuit 3 1) ,5,10,15,20,30 Rated insulation voltage [Ui] (V) Rating A overload, short-circuit 2/3P ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) 3A is not applicable for UDB30H. 2) �2P breaker has same dimension as 3P breaker, but the middle pole is removed. ■ Accessories �Signal Auxiliary switch 1ab, Right-hand-side 2 pole Trip alarm switch 1ab, Right-hand-side 3 pole Shunt trip 1) AUX 10UD R1 ALT 10UD R1 ALT 10UD R2 DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V SHT 10UD A SHT 10UD C SHT 10UD F SHT 10UD H SHT 10UD B SHT 10UD D ※1) The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC �Terminal Terminal cover 1) Interpole barrier 2) 2 pole 3 pole 2EA/SET TQQ 10A ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 2EA, 3 pole 4EA 130 MCCB ■ Standard order code and unit 40/45℃ Model / Breaking capacity at AC220/240V Rated current 3 pole 2 pole Code Unit (EA) Code Unit (EA) 3A UDB30S 2PT4S0000C 00003 46 UDB30S 3PT4S0000C 00003 32 5A UDB30S 2PT4S0000C 00005 46 UDB30S 3PT4S0000C 00005 32 UDB30S 10A UDB30S 2PT4S0000C 00010 46 UDB30S 3PT4S0000C 00010 32 5kA 15A UDB30S 2PT4S0000C 00015 46 UDB30S 3PT4S0000C 00015 32 20A UDB30S 2PT4S0000C 00020 46 UDB30S 3PT4S0000C 00020 32 30A UDB30S 2PT4S0000C 00030 46 UDB30S 3PT4S0000C 00030 32 5A UDB30H 2PT4S0000C 00005 46 UDB30H 3PT4S0000C 00005 32 UDB30H 10A UDB30H 2PT4S0000C 00010 46 UDB30H 3PT4S0000C 00010 32 5-10A : 5kA 15-30A : 10kA 15A UDB30H 2PT4S0000C 00015 46 UDB30H 3PT4S0000C 00015 32 20A UDB30H 2PT4S0000C 00020 46 UDB30H 3PT4S0000C 00020 32 30A UDB30H 2PT4S0000C 00030 46 UDB30H 3PT4S0000C 00030 32 5A UDB50S 2PT4S0000C 00005 46 UDB50S 3PT4S0000C 00005 32 10A UDB50S 2PT4S0000C 00010 46 UDB50S 3PT4S0000C 00010 32 15A UDB50S 2PT4S0000C 00015 46 UDB50S 3PT4S0000C 00015 32 20A UDB50S 2PT4S0000C 00020 46 UDB50S 3PT4S0000C 00020 32 30A UDB50S 2PT4S0000C 00030 46 UDB50S 3PT4S0000C 00030 32 40A UDB50S 2PT4S0000C 00040 46 UDB50S 3PT4S0000C 00040 32 50A UDB50S 2PT4S0000C 00050 46 UDB50S 3PT4S0000C 00050 32 5A UDB50H 2PT4S0000C 00005 46 UDB50H 3PT4S0000C 00005 32 10A UDB50H 2PT4S0000C 00010 46 UDB50H 3PT4S0000C 00010 32 UDB30H 15A UDB50H 2PT4S0000C 00015 46 UDB50H 3PT4S0000C 00015 32 5-10A : 5kA 15-50A : 10kA 20A UDB50H 2PT4S0000C 00020 46 UDB50H 3PT4S0000C 00020 32 30A UDB50H 2PT4S0000C 00030 46 UDB50H 3PT4S0000C 00030 32 40A UDB50H 2PT4S0000C 00040 46 UDB50H 3PT4S0000C 00040 32 50A UDB50H 2PT4S0000C 00050 46 UDB50H 3PT4S0000C 00050 32 15A UDB100S 2PT4S0000C 00015 32 UDB100S 3PT4S0000C 00015 32 20A UDB100S 2PT4S0000C 00020 32 UDB100S 3PT4S0000C 00020 32 UDB50S 5kA 30A UDB100S 2PT4S0000C 00030 32 UDB100S 3PT4S0000C 00030 32 UDB100S 40A UDB100S 2PT4S0000C 00040 32 UDB100S 3PT4S0000C 00040 32 5kA 50A UDB100S 2PT4S0000C 00050 32 UDB100S 3PT4S0000C 00050 32 60A UDB100S 2PT4S0000C 00060 32 UDB100S 3PT4S0000C 00060 32 75A UDB100S 2PT4S0000C 00075 32 UDB100S 3PT4S0000C 00075 32 100A UDB100S 2PT4S0000C 00100 32 UDB100S 3PT4S0000C 00100 32 15A UDB100H 2PT4S0000C 00015 32 UDB100H 3PT4S0000C 00015 32 20A UDB100H 2PT4S0000C 00020 32 UDB100H 3PT4S0000C 00020 32 30A UDB100H 2PT4S0000C 00030 32 UDB100H 3PT4S0000C 00030 32 UDB100H 40A UDB100H 2PT4S0000C 00040 32 UDB100H 3PT4S0000C 00040 32 10kA 50A UDB100H 2PT4S0000C 00050 32 UDB100H 3PT4S0000C 00050 32 60A UDB100H 2PT4S0000C 00060 32 UDB100H 3PT4S0000C 00060 32 75A UDB100H 2PT4S0000C 00075 32 UDB100H 3PT4S0000C 00075 32 100A UDB100H 2PT4S0000C 00100 32 UDB100H 3PT4S0000C 00100 32 Specification Screw type terminal connection, No option, 50/60Hz Category MCCB /M1 Molded Case Circuit Breaker_ 131 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit 50℃ Model / Breaking capacity at AC220/240V 3 pole 2 pole Code Unit (EA) Code Unit (EA) 3A UDB30S 2PT5S0000C 00003 46 UDB30S 3PT5S0000C 00003 32 5A UDB30S 2PT5S0000C 00005 46 UDB30S 3PT5S0000C 00005 32 UDB30S 10A UDB30S 2PT5S0000C 00010 46 UDB30S 3PT5S0000C 00010 32 5kA 15A UDB30S 2PT5S0000C 00015 46 UDB30S 3PT5S0000C 00015 32 20A UDB30S 2PT5S0000C 00020 46 UDB30S 3PT5S0000C 00020 32 30A UDB30S 2PT5S0000C 00030 46 UDB30S 3PT5S0000C 00030 32 5A UDB30H 2PT5S0000C 00005 46 UDB30H 3PT5S0000C 00005 32 UDB30H 10A UDB30H 2PT5S0000C 00010 46 UDB30H 3PT5S0000C 00010 32 5-10A : 5kA 15-30A : 10kA 15A UDB30H 2PT5S0000C 00015 46 UDB30H 3PT5S0000C 00015 32 20A UDB30H 2PT5S0000C 00020 46 UDB30H 3PT5S0000C 00020 32 30A UDB30H 2PT5S0000C 00030 46 UDB30H 3PT5S0000C 00030 32 5A UDB50S 2PT5S0000C 00005 46 UDB50S 3PT5S0000C 00005 32 10A UDB50S 2PT5S0000C 00010 46 UDB50S 3PT5S0000C 00010 32 15A UDB50S 2PT5S0000C 00015 46 UDB50S 3PT5S0000C 00015 32 20A UDB50S 2PT5S0000C 00020 46 UDB50S 3PT5S0000C 00020 32 30A UDB50S 2PT5S0000C 00030 46 UDB50S 3PT5S0000C 00030 32 40A UDB50S 2PT5S0000C 00040 46 UDB50S 3PT5S0000C 00040 32 50A UDB50S 2PT5S0000C 00050 46 UDB50S 3PT5S0000C 00050 32 5A UDB50H 2PT5S0000C 00005 46 UDB50H 3PT5S0000C 00005 32 10A UDB50H 2PT5S0000C 00010 46 UDB50H 3PT5S0000C 00010 32 UDB30H 15A UDB50H 2PT5S0000C 00015 46 UDB50H 3PT5S0000C 00015 32 5-10A : 5kA 15-50A : 10kA 20A UDB50H 2PT5S0000C 00020 46 UDB50H 3PT5S0000C 00020 32 30A UDB50H 2PT5S0000C 00030 46 UDB50H 3PT5S0000C 00030 32 40A UDB50H 2PT5S0000C 00040 46 UDB50H 3PT5S0000C 00040 32 50A UDB50H 2PT5S0000C 00050 46 UDB50H 3PT5S0000C 00050 32 15A UDB100S 2PT5S0000C 00015 32 UDB100S 3PT5S0000C 00015 32 20A UDB100S 2PT5S0000C 00020 32 UDB100S 3PT5S0000C 00020 32 30A UDB100S 2PT5S0000C 00030 32 UDB100S 3PT5S0000C 00030 32 UDB100S 40A UDB100S 2PT5S0000C 00040 32 UDB100S 3PT5S0000C 00040 32 5kA 50A UDB100S 2PT5S0000C 00050 32 UDB100S 3PT5S0000C 00050 32 60A UDB100S 2PT5S0000C 00060 32 UDB100S 3PT5S0000C 00060 32 UDB50S 5kA 132 Rated current 75A UDB100S 2PT5S0000C 00075 32 UDB100S 3PT5S0000C 00075 32 100A UDB100S 2PT5S0000C 00100 32 UDB100S 3PT5S0000C 00100 32 15A UDB100H 2PT5S0000C 00015 32 UDB100H 3PT5S0000C 00015 32 20A UDB100H 2PT5S0000C 00020 32 UDB100H 3PT5S0000C 00020 32 30A UDB100H 2PT5S0000C 00030 32 UDB100H 3PT5S0000C 00030 32 UDB100H 40A UDB100H 2PT5S0000C 00040 32 UDB100H 3PT5S0000C 00040 32 10kA 50A UDB100H 2PT5S0000C 00050 32 UDB100H 3PT5S0000C 00050 32 60A UDB100H 2PT5S0000C 00060 32 UDB100H 3PT5S0000C 00060 32 75A UDB100H 2PT5S0000C 00075 32 UDB100H 3PT5S0000C 00075 32 100A UDB100H 2PT5S0000C 00100 32 UDB100H 3PT5S0000C 00100 32 Specification Category Screw type terminal connection, No option, 50/60Hz MCCB /M1 MCCB | Miniature type / Earth leakage circuit breaker UGD type 30AF | �UGD30L 5kA �UGD30H 5kA UGD30L UGD30H 30AF 2 IP20 A earth leakage, overload, short-circuit 15, 20, 30 15, 30 AC250 AC220 6 0.03 Ampere frame size Number of poles (P) Degree of protection Utilization category Protection Rated current (A) Rated residual current [I△n] (mA) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Rated operating time (sec.) Rated Ultimate [Icu] AC220/240V, 50-60Hz short-circuit breaking capacity (kA r.m.s.) IEC 60947-2 Service [Ics] % of [Icu] K 60947-2 Earth leakage detection Earth leakage test button Trip mechanism Thermal magnetic Direct mounting by screw Mounting DIN-rail Terminal connection Screw d a a Width c Dimensions b Height 2P b (mm) c Depth d Weight (kg, breaker only) 2P 5 50 by current transformer ○ ○ ○ Earth leakage protection ○ - ○ 35 82.5 42 54.6 0.12 60 76 0.14 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. ■ Standard order code and unit 15mA Model / Breaking capacity at AC220/240V UGD30L 5kA UGD30H 5kA Rated current 15A 20A 30A 15A 20A 30A 2 pole Code UGD30L 2PG3S0000C 00015 UGD30L 2PG3S0000C 00020 UGD30L 2PG3S0000C 00030 UGD30H 2PG3S0000C 00015 UGD30H 2PG3S0000C 00020 UGD30H 2PG3S0000C 00030 Unit (EA) 100 100 100 100 100 100 Specification Category 15mA, 40/45℃, Screw type terminal connection, No option, 50/60Hz ELCB/M6 Specification Category 30mA Model / Breaking capacity at AC220/240V UGD30L 5kA UGD30H 5kA Rated current 15A 20A 30A 15A 20A 30A 2 pole Code UGD30L 2PG4S0000C 00015 UGD30L 2PG4S0000C 00020 UGD30L 2PG4S0000C 00030 UGD30H 2PG4S0000C 00015 UGD30H 2PG4S0000C 00020 UGD30H 2PG4S0000C 00030 Unit (EA) 100 100 100 100 100 100 30mA, 40/45℃, Screw type terminal connection, No option, 50/60Hz ELCB/M6 Molded Case Circuit Breaker_ 133 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes | Miniature type / Earth leakage circuit breaker UMG type 30-50AF | �UMG30R 2.5kA �UMG30S 5kA �UMG50S 5kA UMG30R UMG30S UMG30H UMG50S UMG50H �UMG30H 10kA �UMG50H 10kA Ampere frame size Number of poles (P) Degree of protection Utilization category Protection Rated current (A) Rated residual current [I△n] (mA) Rated insulation voltage [Ui] (V) Rating Rated operational voltage [Ue] (V) Rated impulse withstand voltage [Uimp] (kV) Rated operating time (sec.) Rated Ultimate [Icu] AC220/240V, 50-60Hz short-circuit (kA r.m.s.) breaking capacity IEC 60947-2 Service [Ics] % of [Icu] K 60947-2 Earth leakage detection Earth leakage protection Earth leakage test button Hydraulic magnetic Trip mechanism Thermal magnetic Direct mounting by screw Mounting DIN-rail Terminal connection Screw d a a c Width Dimensions b Height 2P b (mm) c Depth d Weight (kg, breaker only) 2P 30AF 2 IP20 A earth leakage, overload, short-circuit 15, 20, 30 15,30 AC250 AC220 6 0.03 2.5 5 50AF 2 IP20 A earth leakage, overload, short-circuit 15, 20, 30, 40, 50 15,30 AC250 AC220 6 0.03 10 5 10 50 50 by current transformer ○ by current transformer ○ ○ ○ ○ ○ ○ 35 80 60 76 0.15 - - ○ ○ ○ ○ ○ ○ 33 70 42 57 0.1 35 80 60 76 0.13 ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. ■ Standard order code and unit 15mA Model / Breaking capacity at AC220/240V Rated current UMG30R 2.5kA 15A 20A 30A 15A 20A 30A 15A 20A 30A 15A 20A 30A 40A 50A 15A 20A 30A 40A 50A UMG30S 5kA UMG30H 10kA UMG50S 5kA UMG50H 10kA 2 pole Code UMG30R 2PG3S0000C 00015 UMG30R 2PG3S0000C 00020 UMG30R 2PG3S0000C 00030 UMG30S 2PG3S0000C 00015 UMG30S 2PG3S0000C 00020 UMG30S 2PG3S0000C 00030 UMG30H 2PG3S0000C 00015 UMG30H 2PG3S0000C 00020 UMG30H 2PG3S0000C 00030 UMG50S 2PG3S0000C 00015 UMG50S 2PG3S0000C 00020 UMG50S 2PG3S0000C 00030 UMG50S 2PG3S0000C 00040 UMG50S 2PG3S0000C 00050 UMG50H 2PG3S0000C 00015 UMG50H 2PG3S0000C 00020 UMG50H 2PG3S0000C 00030 UMG50H 2PG3S0000C 00040 UMG50H 2PG3S0000C 00050 Unit(EA) 150 150 150 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 Specification Category 15mA, 40/45℃, Screw type terminal connection, No option, 50/60Hz ELCB/M6 Specification Category 30mA Model / Breaking capacity at AC220/240V Rated current UMG30R 2.5kA 15A 20A 30A 15A 20A 30A 15A 20A 30A 15A 20A 30A 40A 50A 15A 20A 30A 40A 50A UMG30S 5kA UMG30H 10kA UMG50S 5kA UMG50H 10kA 134 2 pole Code UMG30R 2PG4S0000C 00015 UMG30R 2PG4S0000C 00020 UMG30R 2PG4S0000C 00030 UMG30S 2PG4S0000C 00015 UMG30S 2PG4S0000C 00020 UMG30S 2PG4S0000C 00030 UMG30H 2PG4S0000C 00015 UMG30H 2PG4S0000C 00020 UMG30H 2PG4S0000C 00030 UMG50S 2PG4S0000C 00015 UMG50S 2PG4S0000C 00020 UMG50S 2PG4S0000C 00030 UMG50S 2PG4S0000C 00040 UMG50S 2PG4S0000C 00050 UMG50H 2PG4S0000C 00015 UMG50H 2PG4S0000C 00020 UMG50H 2PG4S0000C 00030 UMG50H 2PG4S0000C 00040 UMG50H 2PG4S0000C 00050 Unit(EA) 150 150 150 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 30mA, 40/45℃, Screw type terminal connection, No option, 50/60Hz ELCB/M6 MCCB | Miniature type / Earth leakage circuit breaker UDG type 30-100AF | �UDG30S 5kA �UDG50S 5kA �UDG100S 5kA �UDG30H 10kA �UDG50H 10kA �UDG100H 10kA UDG30S UDG30H UDG50S UDG50H UDG100S UDG100H Ampere frame size 30AF 50AF 100AF 2, 3 2, 3 *2, 3 IP20 IP20 IP20 A A A earth leakage, overload, short-circuit earth leakage, overload, short-circuit earth leakage, overload, short-circuit 3 1), 5,10,15,20,30 5,10,15,20,30,40,50 15,20,30,40,50,60,75,100 15, 30 15, 30 30, 100 AC460 AC460 AC460 Rating 2P: AC220 2P: AC220 2P: AC220 Rated operational voltage [Ue] (V) 3P: AC220/460 3P: AC220/460 3P: AC220/460 Rated impulse withstand voltage [Uimp] (kV) 6 6 6 Rated operating time (sec.) 0.03 0.03 0.03 5-10A: 2.5 5-10A: 2.5 AC440/460V, 50-60Hz 2.5 2.5 2.5 5 Rated 15-30A: 5 15-50A: 5 Ultimate short-circuit 5-10A: 2.5 5-10A: 2.5 AC380/415V, 50-60Hz 2.5 2.5 2.5 5 breaking capacity [Icu] 15-30A: 5 15-50A: 5 (kA r.m.s.) 5-10A: 5 5-10A: 5 IEC 60947-2 AC220/240V, 50-60Hz 5 5 5 10 15-30A: 10 15-50A: 10 K 60947-2 Service [Ics] % of [Icu] 50 50 50 Earth leakage detection by current transformer by current transformer by current transformer Earth leakage ○ ○ ○ Earth leakage test button protection ○ ○ ○ Earth leakage indicator ○ ○ ○ Trip mechanism Hydraulic magnetic ○ ○ ○ Direct mounting by screw Mounting ○ ○ ○ DIN-rail ○ ○ ○ Terminal connection Screw d a a Width c 50/75 50/75 75 2)/75 Dimensions b Height 96 96 96 2/3P b (mm) c Depth 60 60 60 d 80 80 80 Weight (kg, breaker only) 2/3P 0.33/0.44 0.33/0.44 0.46/0.63 Number of poles (P) Degree of protection Utilization category Protection Rated current (A) Rated residual current [I△n] (mA) Rated insulation voltage [Ui] (V) ※ - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1) 3A is not applicable for UDG30H. 2) �2P breaker has same dimension as 3P breaker, but the middle pole is removed. ■ Accessories �Signal Auxiliary switch 1ab, Right-hand-side AUX 10UD R1 1ab, 2 pole ALT 10UD R1 Right-hand-side 3 pole ALT 10UD R2 Trip alarm switch �Terminal Terminal cover 1) Interpole barrier 2) 2 pole 3 pole 2EA/SET TQQ 10A ※ 1) For both line and load side of breaker, 2EA shall be ordered. 2) Supplied as standard component Required quantity for both line and load side of breaker: 2 pole 2EA, 3 pole 4EA Molded Case Circuit Breaker_ 135 U-Series / Molded Case Circuit Breaker Specifications and Standard Order Codes ■ Standard order code and unit 15mA Model / Breaking capacity at AC220/240V UDG30S 5kA UDG30H 5-10A : 5kA 15-30A : 10kA UDG50S 5kA UDG30H 5-10A : 5kA 15-50A : 10kA Rated current 2 pole Code 3 pole Unit (EA) Code Unit (EA) 3A UDG30S 2PG4S0000C 00003 46 UDG30S 3PG4S0000C 00003 32 5A UDG30S 2PG4S0000C 00005 46 UDG30S 3PG4S0000C 00005 32 10A UDG30S 2PG4S0000C 00010 46 UDG30S 3PG4S0000C 00010 32 15A UDG30S 2PG4S0000C 00015 46 UDG30S 3PG4S0000C 00015 32 20A UDG30S 2PG4S0000C 00020 46 UDG30S 3PG4S0000C 00020 32 30A UDG30S 2PG4S0000C 00030 46 UDG30S 3PG4S0000C 00030 32 5A UDG30H 2PG4S0000C 00005 46 UDG30H 3PG4S0000C 00005 32 10A UDG30H 2PG4S0000C 00010 46 UDG30H 3PG4S0000C 00010 32 15A UDG30H 2PG4S0000C 00015 46 UDG30H 3PG4S0000C 00015 32 20A UDG30H 2PG4S0000C 00020 46 UDG30H 3PG4S0000C 00020 32 30A UDG30H 2PG4S0000C 00030 46 UDG30H 3PG4S0000C 00030 32 5A UDG50S 2PG4S0000C 00005 46 UDG50S 3PG4S0000C 00005 32 10A UDG50S 2PG4S0000C 00010 46 UDG50S 3PG4S0000C 00010 32 15A UDG50S 2PG4S0000C 00015 46 UDG50S 3PG4S0000C 00015 32 20A UDG50S 2PG4S0000C 00020 46 UDG50S 3PG4S0000C 00020 32 30A UDG50S 2PG4S0000C 00030 46 UDG50S 3PG4S0000C 00030 32 40A UDG50S 2PG4S0000C 00040 46 UDG50S 3PG4S0000C 00040 32 50A UDG50S 2PG4S0000C 00050 46 UDG50S 3PG4S0000C 00050 32 5A UDG50H 2PG4S0000C 00005 46 UDG50H 3PG4S0000C 00005 32 10A UDG50H 2PG4S0000C 00010 46 UDG50H 3PG4S0000C 00010 32 15A UDG50H 2PG4S0000C 00015 46 UDG50H 3PG4S0000C 00015 32 20A UDG50H 2PG4S0000C 00020 46 UDG50H 3PG4S0000C 00020 32 30A UDG50H 2PG4S0000C 00030 46 UDG50H 3PG4S0000C 00030 32 40A UDG50H 2PG4S0000C 00040 46 UDG50H 3PG4S0000C 00040 32 50A UDG50H 2PG4S0000C 00050 46 UDG50H 3PG4S0000C 00050 32 Specification Category 15mA, 40/45℃, Screw type terminal connection, No option, 50/60Hz ELCB /M6 30mA Model / Breaking capacity at AC220/240V UDG30S 5kA UDG30H 5-10A : 5kA 15-30A : 10kA UDG50S 5kA 136 Rated current 2 pole Code 3 pole Unit (EA) Code Unit (EA) Specification 3A UDG30S 2PG4S0000C 00003 46 UDG30S 3PG4S0000C 00003 32 5A UDG30S 2PG4S0000C 00005 46 UDG30S 3PG4S0000C 00005 32 10A UDG30S 2PG4S0000C 00010 46 UDG30S 3PG4S0000C 00010 32 15A UDG30S 2PG4S0000C 00015 46 UDG30S 3PG4S0000C 00015 32 20A UDG30S 2PG4S0000C 00020 46 UDG30S 3PG4S0000C 00020 32 30A UDG30S 2PG4S0000C 00030 46 UDG30S 3PG4S0000C 00030 32 5A UDG30H 2PG4S0000C 00005 46 UDG30H 3PG4S0000C 00005 32 30mA, 40/45℃, 10A UDG30H 2PG4S0000C 00010 46 UDG30H 3PG4S0000C 00010 32 15A UDG30H 2PG4S0000C 00015 46 UDG30H 3PG4S0000C 00015 32 20A UDG30H 2PG4S0000C 00020 46 UDG30H 3PG4S0000C 00020 32 30A UDG30H 2PG4S0000C 00030 46 UDG30H 3PG4S0000C 00030 32 5A UDG50S 2PG4S0000C 00005 46 UDG50S 3PG4S0000C 00005 32 Screw type terminal connection, No option, 50/60Hz 10A UDG50S 2PG4S0000C 00010 46 UDG50S 3PG4S0000C 00010 32 15A UDG50S 2PG4S0000C 00015 46 UDG50S 3PG4S0000C 00015 32 20A UDG50S 2PG4S0000C 00020 46 UDG50S 3PG4S0000C 00020 32 30A UDG50S 2PG4S0000C 00030 46 UDG50S 3PG4S0000C 00030 32 40A UDG50S 2PG4S0000C 00040 46 UDG50S 3PG4S0000C 00040 32 50A UDG50S 2PG4S0000C 00050 46 UDG50S 3PG4S0000C 00050 32 Category ELCB /M6 MCCB Model / Breaking capacity at AC220/240V Rated current 2 pole Code 3 pole Unit (EA) Code Unit (EA) Specification 5A UDG50H 2PG4S0000C 00005 46 UDG50H 3PG4S0000C 00005 32 10A UDG50H 2PG4S0000C 00010 46 UDG50H 3PG4S0000C 00010 32 UDG30H 15A UDG50H 2PG4S0000C 00015 46 UDG50H 3PG4S0000C 00015 32 5-10A : 5kA 15-50A : 10kA 20A UDG50H 2PG4S0000C 00020 46 UDG50H 3PG4S0000C 00020 32 30A UDG50H 2PG4S0000C 00030 46 UDG50H 3PG4S0000C 00030 32 40A UDG50H 2PG4S0000C 00040 46 UDG50H 3PG4S0000C 00040 32 50A UDG50H 2PG4S0000C 00050 46 UDG50H 3PG4S0000C 00050 32 15A UDG100S 2PG4S0000C 00015 32 UDG100S 3PG4S0000C 00015 32 20A UDG100S 2PG4S0000C 00020 32 UDG100S 3PG4S0000C 00020 32 30A UDG100S 2PG4S0000C 00030 32 UDG100S 3PG4S0000C 00030 32 30mA, 40/45℃, 40A UDG100S 2PG4S0000C 00040 32 UDG100S 3PG4S0000C 00040 32 50A UDG100S 2PG4S0000C 00050 32 UDG100S 3PG4S0000C 00050 32 60A UDG100S 2PG4S0000C 00060 32 UDG100S 3PG4S0000C 00060 32 75A UDG100S 2PG4S0000C 00075 32 UDG100S 3PG4S0000C 00075 32 Screw type terminal connection, No option, 50/60Hz 100A UDG100S 2PG4S0000C 00100 32 UDG100S 3PG4S0000C 00100 32 15A UDG100H 2PG4S0000C 00015 32 UDG100H 3PG4S0000C 00015 32 20A UDG100H 2PG4S0000C 00020 32 UDG100H 3PG4S0000C 00020 32 30A UDG100H 2PG4S0000C 00030 32 UDG100H 3PG4S0000C 00030 32 40A UDG100H 2PG4S0000C 00040 32 UDG100H 3PG4S0000C 00040 32 50A UDG100H 2PG4S0000C 00050 32 UDG100H 3PG4S0000C 00050 32 60A UDG100H 2PG4S0000C 00060 32 UDG100H 3PG4S0000C 00060 32 75A UDG100H 2PG4S0000C 00075 32 UDG100H 3PG4S0000C 00075 32 100A UDG100H 2PG4S0000C 00100 32 UDG100H 3PG4S0000C 00100 32 UDG100S 5kA UDG100H 10kA Category ELCB /M6 100mA Model / Breaking capacity at AC220/240V UDG100S 5kA UDG100H 10kA Rated current 2 pole Code 3 pole Unit (EA) Code Unit (EA) Specification 15A UDG100S 2PG5S0000C 00015 32 UDG100S 3PG5S0000C 00015 32 20A UDG100S 2PG5S0000C 00020 32 UDG100S 3PG5S0000C 00020 32 30A UDG100S 2PG5S0000C 00030 32 UDG100S 3PG5S0000C 00030 32 40A UDG100S 2PG5S0000C 00040 32 UDG100S 3PG5S0000C 00040 32 50A UDG100S 2PG5S0000C 00050 32 UDG100S 3PG5S0000C 00050 32 60A UDG100S 2PG5S0000C 00060 32 UDG100S 3PG5S0000C 00060 32 100mA, 40/45℃, 75A UDG100S 2PG5S0000C 00075 32 UDG100S 3PG5S0000C 00075 32 100A UDG100S 2PG5S0000C 00100 32 UDG100S 3PG5S0000C 00100 32 15A UDG100H 2PG5S0000C 00015 32 UDG100H 3PG5S0000C 00015 32 20A UDG100H 2PG5S0000C 00020 32 UDG100H 3PG5S0000C 00020 32 Screw type terminal connection, No option, 50/60Hz 30A UDG100H 2PG5S0000C 00030 32 UDG100H 3PG5S0000C 00030 32 40A UDG100H 2PG5S0000C 00040 32 UDG100H 3PG5S0000C 00040 32 50A UDG100H 2PG5S0000C 00050 32 UDG100H 3PG5S0000C 00050 32 60A UDG100H 2PG5S0000C 00060 32 UDG100H 3PG5S0000C 00060 32 75A UDG100H 2PG5S0000C 00075 32 UDG100H 3PG5S0000C 00075 32 100A UDG100H 2PG5S0000C 00100 32 UDG100H 3PG5S0000C 00100 32 Category ELCB /M6 Molded Case Circuit Breaker_ 137 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | UAB type / 30-100AF, 5-10kA | Tripping & temperature derating curves Inst. trip current (A) 3 5 10 15 20 30 40 50 60 75 100 36±12 60±20 120±40 180±60 240±80 360±120 480±160 600±200 720±240 900±300 1200±400 Max. (3-30A) �UAB30R �UAB50C �UAB50R �UAB60C �UAB60R Min. (3-30A) Second �UAB30C Tripping time Max. (40-100A) Derating rate for rated current (%) Minute 3-100A Rated current (A) Min. (40-100A) Ambient temperature (°C) �UAB100C �UAD50C ※Characteristic curves are not applicable. Percentage for rated current (%) Current Dimensions ※ : Center line : Handle center line (Unit: mm) � The allowance of 1.5mm is given around the handle frame. Direct mounting 2P Mounting hole Mounting hole 3P 4P Mounting hole M5 screw (3-50A) M8 screw (60-100A) [Connection conductor] 24 7 (Max.) 5.5 (3~50A) 9 (60~100A) Trip button 50 130 82 C3.5 M4×0.7 mounting screw Trip button 50 25 37.5 6 25 75 12.5 15 25 25 6 100 50 8 50 [Terminal part] 24 17 10 60 82 [Drilling holes for mounting] 2P 3P 4P 3P 2P 4P [Panel cut-out] 2P 3P 4P 110 R5 12.5 25 M4×0.7 tapped hole 25 25 for handle exposure (total breaker height: 64mm) 140 (Max.) 7.57.5 Trip button 115 16 30.5 48 12.5 71 35.5 for handle and trip button exposure (total breaker height: 60mm) 96 MCCB Dimensions ※ : Center line (Unit: mm) � The allowance of 1.5mm is given around the handle frame. : Handle center line Plug-in mounting [Plug-in connection part] [Mounting base] 41 80 M4 nut+S/W+P/W 50 20 18.5 RH screw M4×L18+S/W+P/W 25 162 28 115 130 87 6 180 10.2 28 M4 nut+S/W+P/W M6 nut+S/W+P/W 18.5 2 23.5 80 2 22 102 [Panel cut-out] [Drilling holes for mounting] [Connection conductor] 83 25 A 34 B 4- 6 hole 180 55 6.5 34 19.5 81 21(Max.) 10(Max.) 25 A Cut-out before bus bar assembly. B Cut-out for wiring of signal accessories. ※ TDF 10A for line side only type plug-in mounting, please refer to page 216. Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch Shunt trip Under voltage trip 3 Right Left Handle ※ - AXT is combintaion of AUX and ALT. - In case of 2P, all signal accessories shall be installed in left side of breaker. - UVT operates at DC voltage. AC voltage will be converted to DC through UVT controller. [ Front ] Molded Case Circuit Breaker_ 141 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | UAB type / 50-100AF, 25-30kA | Tripping & temperature derating curves 15-32A Rated current (A) Inst. trip current (A) 15 16 20 25 30 32 300±60 320±72 400±80 500±100 600±120 640±128 Minute Max. Tripping time Second �UAB50S �UAB50H �UAB100R Min. Derating rate for rated current (%) �UAB100S Ambient temperature (°C) �UAD50S �UAD100R Percentage for rated current (%) Current ※Characteristic curves are not applicable. Inst. trip current (A) 40 50 60 63 75 80 100 400±80 500±100 600±120 630±126 750±150 800±160 1000±200 Minute Max. Tripping time Second Min. Derating rate for rated current (%) 40-100A Rated current (A) Percentage for rated current (%) Current Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch Shunt trip Under voltage trip 3 Right Left Handle [ Front ] 142 Ambient temperature (°C) ※ - AXT is combintaion of AUX and ALT. - In case of 2P, all signal accessories shall be installed in left side of breaker. - UVT operates at DC voltage. AC voltage will be converted to DC through UVT controller. MCCB Dimensions ※ : Center line : Handle center line (Unit: mm) � The allowance of 1.5mm is given around the handle frame. Direct mounting 2P Mounting hole 3P 4P Mounting hole M5 screw (15-50A) M8 screw (60-100A) Mounting hole [Connection conductor] 24 7 (Max.) 5.5 (15~30A) 9 (60~100A) C3.5 83.5 20.5 50 115 130 8.6 22 Trip button Trip button [Terminal part] 7.2 Trip button 15 (Max.) M4×0.7 mounting screw 50 75 25 25 100 4.6 50 8 [Drilling holes for mounting] [Panel cut-out] 4P 3P 2P 4P 2P 3P 4P 53 3P 24 16.4 82 110 2P 10 50 56 60 25 7 25 37.5 12.5 M4×0.7 tapped hole 25 25 25 48 for handle exposure (total breaker height: 64mm) 12.5 35.5 71 96 for handle and trip button exposure (total breaker height: 60mm) Plug-in mounting 41 RH screw M4×L18+S/W+P/W 56.100 [Mounting base] 80 50 25 23.5 80 [Panel cut-out] 83 25 101 2 115 162 10.2 87 [Drilling holes for mounting] 22 25 A [Connection conductor] 34 B A Cut-out before bus bar assembly. B Cut-out for wiring of signal accessories. 55 21(Max.) 180 19.5 34 81 4- 6 hole 6.5 10(Max.) M6 nut+S/W+P/W 2 18.5 28 130 6 180 28 M4 nut+S/W+P/W M4 nut+S/W+P/W 20 18.5 [Plug-in connection part] ※ TDF 10A for line side only type plug-in mounting, please refer to page 216. Molded Case Circuit Breaker_ 143 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | UCB type / 50-100AF, 25-36kA | Tripping & temperature derating curves Max. (60-100A) Tripping time Max. (40, 50A) �UCB50R Min. (40-100A) Inst. trip current (A) 15 16 20 25 30 32 40 50 60 63 75 80 100 150±30 160±32 200±40 250±50 300±60 320±64 400±80 500±100 600±120 630±126 750±150 800±160 1000±200 Derating rate for rated current (%) Minute Hour 15-100A Rated current (A) Max. (15-30A) Min. (15-30A) Second �UCB100R 15-30A 40-100A �UCB100S Ambient temperature (°C) �UCD100S ※Characteristic curves are not applicable. Percentage for rated current (%) Current Dimensions ※ : Center line � The allowance of 1.5mm is given around the handle frame. : Handle center line (Unit: mm) Direct mounting 4P Mounting hole Mounting hole M8 screw [Connection conductor] 24 8.5 (Max.) 3P 2P Mounting hole Trip button Trip button 101.5 50 17 (Max.) M4×0.7 mounting screw 37 [Terminal part] 7.3 Trip button 155 16 134 9 Hole 60 90 30 30 30 15 22 10 45 120 30 [Panel cut-out] 4P 3P 2P 4P 2P 3P 4P 53 15 24 Inhex bolt M8×L25 132 3P 6.5 17.4 84.5 [Drilling holes for mounting] 2P 60 10.5 30 60 M4×0.7 30 tapped hole 59 30 88 44 26 for handle exposure (total breaker height: 64mm) 144 15 for handle and trip button exposure (total breaker height: 60mm) 118 MCCB Dimensions ※ : Center line : Handle center line (Unit: mm) � The allowance of 1.5mm is given around the handle frame. Plug-in mounting [Plug-in connection part] [Mounting base] 41 RH screw M5×L20+S/W+P/W 94 M5 nut+S/W+P/W 21 M5 nut+S/W+P/W 60 134 2 46 27.5 M6 nut+S/W+P/W 172.5 13.5 48 191 155 6 99 27.5 30 23.5 81 2 105.5 [Panel cut-out] 26.5 [Drilling holes for mounting] 97 80 A 30 4- 5.5 hole 33.5 26 (Max.) 191 55 19.5 6.5 33.5 93 13(Max.) [Connection conductor] B A Cut-out before bus bar assembly. B Cut-out for wiring of signal accessories. ※ TDF 10B for line side only type plug-in mounting, please refer to page 216. Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch Shunt trip Under voltage trip 3 Right Left Handle ※ - AXT is combintaion of AUX and ALT. - In case of 2P, all signal accessories shall be installed in left side of breaker. SHT and UVT are not applicable to 2P. - UVT operates at DC voltage. AC voltage will be converted to DC through UVT controller. [ Front ] Molded Case Circuit Breaker_ 145 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | UCB type / 50-125AF, 42-50kA | Tripping & temperature derating curves Hour 15-32A Minute Rated current (A) Inst. trip current (A) 15 16 20 25 30 32 225±45 240±48 300±60 375±75 450±90 480±96 Derating rate for rated current (%) Tripping time �UCB50H Second �UCB50L �UCB100H Max. �UCB100L Min. 16-30A Ambient temperature (°C) �UCD50H �UCD100H Percentage for rated current (%) Current ※Characteristic curves are not applicable. 40-125A Rated current (A) Inst. trip current (A) 40 50 60 63 75 80 100 125 400±80 500±100 600±120 630±126 750±150 800±160 1000±200 1250±250 Max. (60-125A) Tripping time Max. (40, 50A) Min. (40-125A) Second Derating rate for rated current (%) Minute Hour Ambient temperature (°C) Percentage for rated current (%) Current Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch Shunt trip Under voltage trip 3 Right Left Handle [ Front ] 146 40-125A ※ - AXT is combintaion of AUX and ALT. - UVT operates at DC voltage. AC voltage will be converted to DC through UVT controller. MCCB Dimensions ※ : Center line � The allowance of 1.5mm is given around the handle frame. : Handle center line (Unit: mm) Direct mounting 2P, 3P 4P M8 screw 24 [Connection conductor] 101 M4×L60 mounting screw 37 17 (Max.) [Terminal part] 8 90 30 120 10 30 48 55 10 60 84.5 18 [Drilling holes for mounting] [Panel cut-out] 4P 3P 4P 3P 30 30 53 132 3P 24 Inhex bolt M8×L25 30 4P 53 30 8.5 30 53 30 10.5 Trip button 155 50 134 16 Trip button 8.5(Max.) 9 hole 23 44 88 25 118 M4 tapped hole for handle exposure (total breaker height: 66mm) Plug-in mounting for handle and trip button exposure (total breaker height: 60mm) [Mounting base] [Plug-in connection part] 41 21 RH screw M5×L20+S/W+P/W 94 60 30 M5 nut+S/W+P/W 134 27.0 46 M6 nut+S/W+P/W 2 23.5 81 2 105.5 26 5 [Drilling holes for mounting] 97 80 30 [Connection conductor] A 4- 5.5 hole 26 (Max.) 191 55 19.5 6.5 33.5 93 33.5 B 13 (Max.) [Panel cut-out] 172.5 99 155 6 191 13.5 46 27.5 M5 nut+S/W+P/W A Cut-out before bus bar assembly. B Cut-out for wiring of signal accessories. ※ TDF 10B for line side only type plug-in mounting, please refer to page 216. Molded Case Circuit Breaker_ 147 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | UCB type / 250AF, 18-36kA | Tripping & temperature derating curves Hour 125-250A Rated current (A) Derating rate for rated current (%) Minute 1250±250 1500±300 1600±320 1750±350 2000±400 2250±450 2500±500 Max. Tripping time �UCB250R Inst. trip current (A) 125 150 160 175 200 225 250 Min. Second �UCB250S �UCB250N Ambient temperature (°C) �UCD250S ※Characteristic curves are not applicable. Percentage for rated current (%) Current Dimensions ※ : Center line � The allowance of 1.5mm is given around the handle frame. : Handle center line 97 23 Direct mounting Mounting hole 3P 4P Mounting hole 23 (Unit: mm) [with terminal bus bar*option] M8 screw 23 35 24 [Terminal part] Trip button 11 M4×0.7 mounting screw [Connection conductor] 11 (Max.) 12 [Drilling holes for mounting] M4×0.7 tapped hole 35 11 23 35 35 35 23 (Max.) [Panel cut-out] 4P 3P 4P 3P 4P 53 125 3P 8 55 11 60 84 28 53 35 35 35 140 24 Inhex bolt M8×L25 10.5 24 9 105 26 103 51.5 138 for handle exposure (total breaker height: 64mm) 148 4 4 35 52.5 70 25 49.5 23 7 11.5 Trip button 14.5 35.5 23.5 26.5 143 164 44.5 51.5 11 for handle and trip button exposure (total breaker height: 60mm) MCCB Dimensions ※ : Center line : Handle center line � The allowance of 1.5mm is given around the handle frame. (Unit: mm) [Mounting base] Plug-in mounting 8 M5 nut+S/W+P/W 21 42 19.5 74 24 M5 screw+S/W+P/W 12.5 25.5 70 185 143 28.5 112 [Plug-in connection part] M8 nut+S/W+P/W 57.5 77.5 24.7 25.5 28 Max. width of conductor : 25mm [Drilling holes for mounting] Attaching angle 25×25×t3 45 6 hole for CBM 20C 2/5 25 19 6 53 24 13 12 15 0.0 6 hole -0.2 70 Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch Shunt trip Under voltage trip 3 Right Left ※ - AXT is combintaion of AUX and ALT. - UVT operates at DC voltage. AC voltage will be converted to DC through UVT controller. Handle [ Front ] Molded Case Circuit Breaker_ 149 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | UCB type / 160-250AF, 42-50kA | Tripping & temperature derating curves Hour 100-250A Rated current (A) 100 125 150 160 175 200 225 250 1000±200 1250±250 1500±300 1600±320 1750±350 2000±400 2250±450 2500±500 Derating rate for rated current (%) Minute Inst. trip current (A) Tripping time �UCB160H Max. Min. Second �UCB160L �UCB250H �UCB250L Ambient temperature (°C) �UCD160H �UCD250H ※Characteristic curves are not applicable. Percentage for rated current (%) Current : Center line Direct mounting 97 23 4P Mounting hole M8 screw [with terminal bus bar*option] 23 24 4 [Terminal part] 23 35 Mounting hole 3P 23 11 4 24 101 M4×L60 mounting screw 45 [Connection conductor] 8 44.5 10 9 35 48 55 60 84.5 10 11 [Drilling holes for mounting] 35 M4 Tapped hole 35 25 for handle exposure (total breaker height: 66mm) 150 35 22 (Max.) 3P 4P 53 53 125 35 35 [Panel cut-out] 4P 3P 4P 3P 23 35 11.5 35 35 140 53 35 11(Max.) 16 50 144 165 23 35 35 105 (Unit: mm) � The allowance of 1.5mm is given around the handle frame. : Handle center line 11 ※ 103 51.5 138 for handle and trip button exposure (total breaker height: 60mm) 10.5 Dimensions 24 Inhex bolt M8×L25 MCCB Dimensions ※ : Center line : Handle center line Plug-in mounting � The allowance of 1.5mm is given around the handle frame. (Unit: mm) M5 nut + S/W + P/W M5 screw + S/W + P/W [Plug-in connection part] [Mounting base] 42 186 144 12.5 19.5 74 24 8 M8 nut + S/W + P/W Max. width of conductor : 25mm 28 25.5 25.5 28.5 70 112 24.7 77.5 57.5 [Drilling holes for mounting] Attaching angle 25×25×t3 45 6 hole for CBM 20C 2/5 25 19 6 53 24 13 12 15 0.0 6 hole -0.2 70 Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch Shunt trip Under voltage trip 3 Right Left ※ - AXT is combintaion of AUX and ALT. - UVT operates at DC voltage. AC voltage will be converted to DC through UVT controller. Handle [ Front ] Molded Case Circuit Breaker_ 151 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | UCB type / 400AF, 30-100kA | Tripping & temperature derating curves Hour 250-400A Rated current (A) �UCB400R Inst. trip current (A) 2500±500 3000±600 3200±640 3500±700 4000±800 Derating rate for rated current (%) Tripping time Minute 250 300 320 350 400 Max. Min. �UCB400S Second �UCB400H �UCB400L Ambient temperature (°C) �UCD400S ※Characteristic curves are not applicable. Percentage for rated current (%) Current Dimensions ※ : Center line : Handle center line � The allowance of 1.5mm is given around the handle frame. (Unit: mm) Direct mounting 표면접속 2P, 3P 4P 143 59 12.5 12.5 59 84 8 37 4 13.5 30 11 12.5 24.5 40 150 95 24.5 317 225 215 150 95 257 30 11 44 59 9.5 59 12.5 202 59 44 40 51 51 15 25 44 25 44 25 25 44 25 140 44 185 25 44 25 80 30.5 13 29 Inhex bolt M8×L30 [Connection conductor] 11 12.5(Max.) [Terminal part] 30(Max.) 152 8 95 110 115.5 145 2 37 M6 mounting screw MCCB Dimensions ※ : Center line : Handle center line � The allowance of 1.5mm is given around the handle frame. [Drilling holes for mounting] (Unit: mm) [Panel cut-out] 4P 95 112 44 98 215 98 2P, 3P 54 2P, 3P (143) 4P (188) for handle exposure for handle and trip button exposure Plug-in mounting [Mounting base] [Drilling holes for mounting] Attaching angle 44.5 21 20 15 89 Supportor pportor 54 112.5 139.5 60 45 21 44.5 15 90 140 65.5 M8 mounting screw M5 screw [Plug-in connection part] 22 113 71.5 6 for supportor 9 60 10 Max. with of conductor : 35mm M10 screw 18 46.5 35 Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch Shunt trip Under voltage trip 3 Right Left ※ - UVT operates at DC voltage. AC voltage will be converted to DC through UVT controller. Handle [ Front ] Molded Case Circuit Breaker_ 153 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | UCB type / 630AF, 45-100kA | Tripping & temperature derating curves Inst. trip current (A) 500 630 5000±1000 6300±1260 Minute Hour 500-630A Rated current (A) �UCB630R �UCB630S Min. Second �UCB630H Derating rate for rated current (%) Tripping time Max. �UCB630L Ambient temperature (°C) �UCD630S ※Characteristic curves are not applicable. Percentage for rated current (%) Current Dimensions ※ : Center line : Handle center line (Unit: mm) � The allowance of 1.5mm is given around the handle frame. Direct mounting 표면접속 2P, 3P 4P 84 280 70 210 70 70 6 34.5 70 72 58 9.5 280 24.5 72 150 95 24.5 280 243 150 95 8 13.5 70 70 6 32 16.5 70 58 70 70 M6 mounting screw 40 70 40 70 Inhex bolt M12xL30 13 12.5 31 46 [Connection conductor] 12.5(Max.) [Terminal part] 154 45 (Max.) 80 4 6 34.5 15 95 110 115.5 145 MCCB Dimensions ※ : Center line (Unit: mm) � The allowance of 1.5mm is given around the handle frame. : Handle center line [Drilling holes for mounting] [Panel cut-out] 4P 95 112 70 98 243 98 2P, 3P 2P, 3P (213) 61 4P (283) for handle exposure for handle and trip button exposure Plug-in mounting [Mounting base] [Drilling holes for mounting] M10 mounting screw 90 Supportor 45 15 25 46.5 71.5 151.5 121.5 140 210 46.5 25 71.5 30 32 18 20 100 151.5 121.5 Attaching angle [Plug-in connection part] M5 screw 21 20 6 for supportor 90 116.2 59 11 45 Max. with of conductor : 40mm M16 screw 44 60 Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch Shunt trip Under voltage trip 3 Right Left ※ - UVT operates at DC voltage. AC voltage will be converted to DC through UVT controller. Handle [ Front ] Molded Case Circuit Breaker_ 155 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | UCB type / 800AF, 45-100kA | Tripping & temperature derating curves 700~800A Rated current (A) Inst. trip current (A) 700 800 7000±1400 8000±1600 Minute Hour 700-800A �UCB800R �UCB800S Min. Second �UCB800H Derating rate for rated current (%) Tripping time Max. �UCB800L Ambient temperature (°C) �UCD800S ※Characteristic curves are not applicable. Percentage for rated current (%) Current Dimensions ※ : Center line : Handle center line � The allowance of 1.5mm is given around the handle frame. (Unit: mm) Direct mounting 2P, 3P 4P 210 280 70 70 6 72 9.5 280 24.5 72 150 95 24.5 280 243 150 95 8 13.5 70 70 70 70 32 16.5 70 84 8 34.5 58 58 70 70 M6 mounting screw 40 70 40 70 Inhex bolt M12xL30 12.5 31 46 156 [Connection conductor] 13 12.5 (Max.) [Terminal part] 45 (Max.) 80 4 8 34.5 15 95 110 115.5 145 MCCB Dimensions ※ : Center line : Handle center line (Unit: mm) � The allowance of 1.5mm is given around the handle frame. [Drilling holes for mounting] [Panel cut-out] 4P 95 112 70 98 243 98 2P, 3P 2P, 3P (213) 61 4P (283) for handle exposure for handle and trip button exposure Plug-in mounting [Mounting base] [Drilling holes for mounting] M10 mounting screw 90 Supportor 45 15 25 46.5 71.5 121.5 151.5 140 210 46.5 25 71.5 30 32 18 20 100 121.5 151.5 Attaching angle [Plug-in connection part] M5 screw 21 20 6 for supportor 90 116.2 59 11 45 Max. with of conductor : 40mm 44 M16 screw 60 Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch Shunt trip Under voltage trip 3 Right Left ※ - UVT operates at DC voltage. AC voltage will be converted to DC through UVT controller. Handle [ Front ] Molded Case Circuit Breaker_ 157 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | UCB type / 1000AF, 100-130kA | Tripping curves Protection characteristics Hour 4 3 2 505-1000A Ir Ig Characteristics Ip 1 50 40 30 Minute 20 8 6 5 4 3 505, 535, 565, 600, 630, 640, 680, 720, 760, 800, 850, 900, 950, 1000 Long time setting [tr] 2-4-6-8-12 sec. at Ir x 600% ±20% Ir x NON-200-400-600-800Short time current ±15% 1000% STD1) setting [Isd] (A) 0-0.1-0.2-0.3 sec. at definite + 50ms Time delay setting time-limit section [tsd]1) - 20ms Instantaneous In x NON-300-600-800INST current setting ±20% 1000-1100% [Ii] (A) Ground fault In x NON-20-30-40% ±15% GFT2) current [Ig] (A) 0.1-0.2-0.3-0.4-0.8 sec. at Ground fault delay + 50ms definite time-limit section setting [tg] - 20ms Pre-trip alarm Ir x 90% ±10% PTA current [Ip] (A) Ii 1 50 40 30 Tripping time �UCB1000L 20 12 10 8 6 5 4 3 Second 2 for I2t "ON" 1 0.8 0.6 0.5 0.4 0.3 0.2 �UCD1000S ※Characteristics are not applicable. for I2t "OFF" 0.1 0.08 0.06 0.05 0.04 0.03 ※ -The default values are underlined. Please check and adjust the setting condition of each characteristic before use. -1) I2t characteristic can be ON or OFF by adjusting the [tsd] knob. -2) GFT protection is option. 3000 2000 2500 500 600 700 800 900 1000 1100 1200 1300 1500 400 250 200 In×% 300 125 150 50 80 90 100 40 30 10 20 0.02 0.01 0.008 0.006 0.005 Tolerance Rated current LTD setting [Ir] (A) Isd 10 2 �UCB1000S Setting value or range Rated (CT) current [In] (A) 1000 Ir×% Current Dimensions ※ Direct mounting : Center line : Handle center line � The allowance of 1.5mm is given around the handle frame. (Unit: mm) UCB1000S Mounting hole 4P M8 mounting screw 73 3P 30 N 14 [Connection conductor] 70 36 20 16 14 25 110 115 159 45 45 70 70 210 70 280 5 7 70 80 [Drilling holes for mounting] 4P 3P 99 61.5 338 44 158 70 8 for trip button 25 Inhex bolt M10×L30 [Panel cut-out] 4P 3P 78.5 M8 tapped hole 25 54 37.5 13 14 516 310 [Terminal part] 16 36 21 73 370 45 MCCB Dimensions ※ Direct mounting : Center line : Handle center line � The allowance of 1.5mm is given around the handle frame. (Unit: mm) UCB1000L Mounting hole M8 screw 4P 73 3P 120 N 14 45 70 70 210 115 14 5 70 280 7 80 16 45 70 200 14 45 70 25 54 205 25 115 249 Inhex bolt M10×L30 [Drilling holes for mounting] [Panel cut-out] 4P 4P 3P 3P 99 61.5 338 78.5 37.5 13 [Terminal part] 73 16 36 21 36 20 310 516 370 [Connection conductor] 44 M8 tapped hole 70 8 for trip button Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch Shunt trip Under voltage trip 3 Left Right ※ - AXT is combintaion of AUX and ALT. Handle [ Front ] Molded Case Circuit Breaker_ 159 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | UCB type / 1250AF, 100-130kA | Tripping curves Protection characteristics Hour 4 3 630-1250A Ir 2 Ig 630, 670, 710, 750, 790, 800, 850, 900, 950, 1000, 1060, 1125, 1190, 1250 Long time setting [tr] 2-4-6-8-12 sec. at Ir x 600% ±20% Ir x NON-200-400-600-800Short time current ±15% 1000% STD1) setting [Isd] (A) 0-0.1-0.2-0.3 sec. at definite + 50ms Time delay setting time-limit section [tsd]1) - 20ms Instantaneous In x NON-300-600-800INST current setting ±20% 1000-1100% [Ii] (A) Ground fault In x NON-20-30-40% ±15% GFT2) current [Ig] (A) 0.1-0.2-0.3-0.4-0.8 sec. at Ground fault delay + 50ms definite time-limit section setting [tg] - 20ms Pre-trip alarm Ir x 90% PTA ±10% current [Ip] (A) Minute Rated current LTD setting [Ir] (A) Isd 10 8 6 5 4 3 2 Ii 1 50 40 30 Tripping time �UCB1250L 20 12 10 8 6 5 4 3 Second 2 �UCD1250S ※Characteristics are not applicable. for I2t "ON" 1 0.8 0.6 0.5 0.4 0.3 0.2 for I2t "OFF" 0.1 0.08 0.06 0.05 0.04 0.03 3000 2000 2500 500 600 700 800 900 1000 1100 1200 1300 1500 400 200 250 In×% 300 125 150 50 80 90 100 40 30 10 20 0.02 0.01 0.008 0.006 0.005 Tolerance Rated (CT) current [In] (A) 1250 20 �UCB1250S Setting value or range Characteristics Ip 1 50 40 30 ※ -The default values are underlined. Please check and adjust the setting condition of each characteristic before use. -1) I2t characteristic can be ON or OFF by adjusting the [tsd] knob. -2) GFT protection is option. Ir×% Current Dimensions ※ Direct mounting UCB1250S : Center line : Handle center line � The allowance of 1.5mm is given around the handle frame. (Unit: mm) Mounting hole 4P M8 mounting screw 73 3P 30 N 14 [Connection conductor] 45 70 70 36 20 16 17 25 110 115 159 45 70 210 70 280 5 7 70 80 [Drilling holes for mounting] [Panel cut-out] 4P 3P 4P 3P 99 61.5 338 78.5 44 M8 tapped hole 160 70 25 54 8 for trip button 37.5 13 14 516 310 [Terminal part] 16 36 21 73 370 45 25 Inhex bolt M10×L30 MCCB Dimensions ※ Direct mounting : Center line � The allowance of 1.5mm is given around the handle frame. : Handle center line (Unit: mm) UCB1250L Mounting hole M8 mounting screw 4P 73 3P 120 N 14 [Connection conductor] 36 20 310 516 370 45 16 45 70 70 210 70 17 70 280 80 115 5 200 7 205 14 45 70 25 54 25 115 Inhex bolt M10×L30 249 [Drilling holes for mounting] [Panel cut-out] 4P 4P 3P 3P 99 61.5 338 78.5 37.5 13 73 16 36 21 [Terminal part] 44 M8 tapped hole 70 8 for trip button Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch Shunt trip Under voltage trip 3 Left Right ※ - AXT is combintaion of AUX and ALT. Handle [ Front ] Molded Case Circuit Breaker_ 161 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | UCB type / 1600AF, 65kA | Tripping curves Protection characteristics 640-1600A Characteristics �UCB1600S Setting value or range Tolerance Rated (CT) current [In] (A) 1600 LTD Second Tripping time I2 Rated current setting [I1] (A) 640, 800, 960, 1120, 1250, 1440, 1520, 1600 Instantaneous INST current setting [I2] (A) I1 x 200-300-400-500-600700-800-1000% ±10% ※ -The default values are underlined. Please check and adjust the setting condition of each characteristic before use. ±20% 100 200 300 400 500 600 800 1000 2000 3000 Percentage for rated current (%) Current Dimensions ※ : Center line � The allowance of 1.5mm is given around the handle frame. : Handle center line (Unit: mm) Direct mounting 13 [with terminal cover and extension handle] [Drilling holes for mounting] 338 394 110 477 371 570 152 11 51 100 32 15 22 Trip button 7 70 151 170 215 [Terminal cover] [Extension handle] 210 d 151 297 210 50 109 40 e R25 36 45 25 60 70 162 70 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | UPB type / 125-250AF, 85-150kA / Adjustable thermal | Tripping & temperature derating curves Percentage for rated current (%) Max. Ambient temperature (°C) Max. Percentage for rated current (%) Current 1250± 375 250 1500± 450 300 1600± 480 320 1750± 525 350 2000± 600 400 2250± 675 450 2500± 750 500 Current Inst. trip current (A) 125 150 160 175 200 225 250 Min. Min. Rated current (A) Second Second Percentage for rated current (%) Derating rate for rated current (%) Tripping time Tripping time 630±126 800±160 1000±200 1250±250 Minute 125-250A 63 80 100 125 Minute Inst. trip current (A) Rated current (A) Hour 63-125A Current Hour ※Characteristic curves are not applicable. Percentage for rated current (%) Current �UPD250S Second Max. Min. �UPD100S �UPD160S 164 �UPB250L �UPB250X Max. Min. �UPB250S �UPB250H �UPB160L �UPB160X �UPB160S �UPB160H 400±80 500±100 40~50A Inst. trip current (A) 40 50 Second �UPB100L �UPB100X 150±30 160±32 200±40 250±50 300±60 320±64 Tripping time Tripping time �UPB100S �UPB100H Rated current (A) Minute 40-50A 15 16 20 25 30 32 Inst. trip current (A) Rated current (A) Hour 15-30A Minute Hour MCCB Dimensions ※ : Center line : Handle center line (Unit: mm) � The allowance of 1.5mm is given around the handle frame. Direct mounting 4P 140 35 35 35 4P 3P 27.5 144 165 144 *A 144 165 146 [Panel cut-out] 4P 3P 112 20 11 23 [Drilling holes for mounting] 75.5 3P 105 35 11 19 45 11 20 11 R5 M4×0.7 tapped hole 45 35 90 113 [Connection conductor] [Terminal part] 35 128 71 86.5 35 30 [with terminal bus bar*option] Dimension A 8.5 9.5 9.5 9 (Max.)9 35 M4 tap O.7 23 23 (Max.) 24 10 Line side : 24mm for UPB100 26mm for UPB160, UPB250 Load side : 24mm 24 t4 A Plug-in mounting [Mounting base] 41 24 5 [Drilling holes for mounting] [Plug-in connection part] 109 35 4- 6 mounting hole 26.5 15 23 [Panel cut-out] 96 4-M5 tap 4- 6 tap 37 30 15 31 92.5 110 35 70 105 190 179 113 144 175 190 35 107 30 31 M8 bolt 70 M8 mounting screw 22.5 26 Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch Shunt trip Under voltage trip 3 Left Right Handle [ Front ] Molded Case Circuit Breaker_ 165 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | UPB type / 125-250AF, 85-150kA / Electronic | Tripping curves Hour 4 3 2 50-250A 1 50 40 30 Ir = 125, 160, 250 Minute 20 10 8 6 5 4 3 2 1 50 40 30 �UPB100S �UPB100H 20 Tripping time �UPB100L �UPB100X �UPB160S �UPB160H �UPB160L �UPB160X 10 8 6 5 4 3 2 Isd = 2..... 10 x Ir Second 1 0.8 0.6 0.5 0.4 0.3 0.2 �UPB250S �UPB250H �UPB250L �UPB250X 0.1 0.8 0.6 0.5 0.4 0.3 0.2 Max. total breaking time t < 10ms Ii = 11 x In 0.01 0.8 0.6 0.5 50 70 100 150 200 300 400 500 700 1000 1500 2000 3000 4000 5000 7000 8000 10000 15000 20000 Ir×% Current Protection characteristics Setting value or range Characteristics Rated (CT) current [In] (A) LTD STD PTA UPB160 UPB250 125 160 250 Rated current setting [Ir] (A) 50, 55, 63, 70, 63, 70, 80, 90, 100, 110, 125, 80, 90, 100, 100, 110, 125, 140, 160, 175, 115, 125 140, 160 200, 225, 250 Long time setting [tr] 6.25 sec. at Ir x 600% Short time current setting Ir x NON-200-300-400-500-600-700-800-900- [Isd] (A) Time delay setting [tsd] INST UPB100 Instantaneous current ±20% 1000% 0.05-0.1-0.2-0.3 sec. at definite time-limit + 50ms section - 20ms In x 1100% ±20% Ir x 90% ±10% setting [Ii] (A) Pre-trip alarm current [Ip] (A) Tolerance ※ -The default values are underlined. Please check and adjust the setting condition of each characteristic before use. 166 30000 MCCB Dimensions ※ : Center line : Handle center line � The allowance of 1.5mm is given around the handle frame. (Unit: mm) Direct mounting 4P 140 35 35 35 4P 3P 27.5 144 165 144 *A 144 165 146 [Panel cut-out] 4P 3P 112 20 11 23 [Drilling holes for mounting] 75.5 3P 105 35 11 19 45 11 20 11 R5 M4×0.7 tapped hole 45 35 90 113 [Connection conductor] [Terminal part] 35 128 71 86.5 35 30 [with terminal bus bar*option] Dimension A 8.5 9.5 9.5 9 (Max.)9 35 M4 tap O.7 23 23 (Max.) 24 10 Line side : 24mm for UPB100 26mm for UPB160, UPB250 Load side : 24mm 24 t4 A Plug-in mounting 41 24 5 [Panel cut-out] [Drilling holes for mounting] [Plug-in connection part] 109 35 4- 6 mounting hole 26.5 15 23 [Mounting base] 96 4-M5 tap 31 4- 6 tap 37 30 15 92.5 110 35 70 105 190 179 113 144 175 190 35 107 30 31 M8 bolt 70 M8 mounting screw 22.5 26 Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch Shunt trip Under voltage trip 3 Left Right Handle [ Front ] Molded Case Circuit Breaker_ 167 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | UPB type / 400-630AF, 85-150kA | Tripping curves Protection characteristics Hour 4 3 200-630A Ir 2 Ig Setting value or range Characteristics 1 50 40 30 UPB630 630 200, 215, 225, 240, 250, 255, 270, 290, 300, 320, 340, 360, 380, 400 320, 340, 360, 380, 400, 430, 450, 480, 500, 540, 570, 600, 630 Rated (CT) current [In] (A) 20 Minute UPB400 400 Ip Isd 10 8 6 5 4 3 LTD 2 Rated current setting [Ir] (A) Ii Tolerance 1 Tripping time 50 40 30 �UPB400S �UPB400H Long time setting [tr] Short time current setting [Isd] (A) 1) STD Time delay setting [tsd]1) Instantaneous INST current setting [Ii] (A) Ground fault current [Ig] (A) GFT2) Ground fault delay setting [tg] Pre-trip alarm PTA current [Ip] (A) 20 12 10 8 6 5 4 3 2 Second �UPB400L �UPB400X �UPB630S �UPB630H for I2t "ON" 1 0.8 0.6 0.5 0.4 0.3 0.2 �UPB630L �UPB630X 2 for I t "OFF" 0.1 0.08 0.06 0.05 0.04 0.03 �UPD400S �UPD630S Ir×% Current Dimensions ※ Direct mounting : Center line : Handle center line In x NON-300-600-8001000-1100% ±20% In x NON-20-30-40% ±15% 0.1-0.2-0.3-0.4-0.8 sec. at definite time-limit section + 50ms - 20ms Ir x 90% ±10% ※ -The default values are underlined. Please check and adjust the setting condition of each characteristic before use. -1) I2t characteristic can be ON or OFF by adjusting the [tsd] knob. -2) GFT protection is option. 3000 2000 2500 500 600 700 800 900 1000 1100 1200 1300 1500 400 250 In×% 300 125 150 200 50 80 90 100 40 ※Characteristics are not applicable. 30 0.01 0.008 0.006 0.005 10 20 0.02 2-4-6-8-12 sec. at Ir x 600% ±20% Ir x NON-200-400-600-800±15% 1000% 0-0.1-0.2-0.3 sec. at definite + 50ms time-limit section - 20ms � The allowance of 1.5mm is given around the handle frame. UPB400, UPD400S 15 12.5 6 39.5 16 47 M10 screw 201 161.5 112.5 142.5 255 98.5 128.5 16 16 16 47 [with terminal bus bar*option] 185 27.5 24 15 140 27.5 12.5 15 24 4P 3P 16 52.5 13 60 150 [Drilling holes for mounting] M5 mounting screw 10 60 [Panel cut-out] 4P 3P 4P [Connection conductor] [Terminal part] 10.5 113 15 (Max.) 100 130 168 45 119.5 159.5 63 30 (Max.) 14 16 3P 60 210 30 15 60 16 47 16 47 60 15 30 13 15 16 81 M5 tapped hole (Unit: mm) 34 33.5 Inhex bolt M10×L30 MCCB : Handle center line UPB630, UPD630S [with terminal bus bar*option] 112.5 255 142.5 16 98.5 128.5 41.5 8 M10 screw 85.5 12.5 24 16 16 15 47 140 185 27.5 24 3P 27.5 12.5 15 16 15 47 4P (Unit: mm) � The allowance of 1.5mm is given around the handle frame. 55 Direct mounting : Center line 102.5 ※ 115.5 Dimensions 30 16 13 60 150 52.5 60 30 M5 mounting screw 15 60 15 16 47 16 16 47 60 15 13 81 10 119.5 159.5 60 210 [Drilling holes for mounting] 3P [Panel cut-out] 4P 3P 4P [Connection conductor] [Terminal part] M5 tapped hole 45 Plug-in mounting [Mounting base] [Panel cut-out] 22.5 144 45 [Drilling holes for mounting] 155 M10 mounting screw 122 127 159 45 90 140 39 52.5 22.5 11.5 18.5 298 274 188 227 270 298 [Plug-in connection part] 27 4-M5 tap 37.5 30 37.5 180 33.5 Inhex bolt M10×L30 34 30 (Max.) 63 130 57.7 33.5 5 14 16 15 (Max.) 113 41.5 130 100 10.5 90 27 Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch Shunt trip Under voltage trip 3 Left Right Handle [ Front ] Molded Case Circuit Breaker_ 169 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | Motor protection / UPB type 125-250AF, 100-130kA | Tripping curves 125A Minute Max. Percentage for rated current (%) Current Instantaneous trip current UPB100 Rated current (A) 6 7 8 9 10 11 12 13 2.5 15 17.5 20 22.5 25 27.5 30 32.5 3.2 19.2 22.4 25.6 28.8 32 35.2 38.4 41.6 6.3 37.8 44.1 50.4 56.7 63 69.3 75.6 81.9 12.5 75 87.5 100 112.5 125 137.5 150 162.5 20 120 140 160 180 200 220 240 260 32 192 224 256 288 320 352 384 416 50 300 350 400 450 500 550 600 650 63 378 441 504 567 630 693 756 819 80 480 560 640 720 800 880 960 1040 100 600 700 800 900 1000 1100 1200 1300 Multiple for rated current ※ Tolerance for setting current: -20% - +30% UPB250 Rated current (A) 5 6 7 8 9 10 125 625 750 875 1000 1125 1250 150 750 900 1050 1200 1350 1500 175 875 1050 1225 1400 1575 1750 200 1000 1200 1400 1600 1800 2000 225 1125 1350 1575 1800 2025 2250 Multiple for rated current ※ Tolerance for setting current: -20% - +30% Percentage for rated current (%) Current 170 Max. Min. Second Min. Instantaneous trip current (500-1000%) Tripping time Tripping time �UPB250L �UPB250H Second �UPB100L Instantaneous trip current (600-1300%) Minute �UPB100H 250A Hour Hour MCCB Dimensions ※ : Center line � The allowance of 1.5mm is given around the handle frame. : Handle center line (Unit: mm) Direct mounting 4P 140 35 35 35 4P 3P 27.5 144 165 144 *A 144 165 146 [Panel cut-out] 4P 3P 112 20 11 23 [Drilling holes for mounting] 75.5 3P 105 35 11 19 45 11 20 11 R5 M4×0.7 tapped hole 45 35 90 113 [Connection conductor] [Terminal part] 35 128 71 86.5 35 30 Dimension A 8.5 9.5 9.5 9 (Max.)9 35 M4 tap O.7 [with terminal bus bar*option] 23 (Max.) 24 10 23 Line side : 24mm for UPB100 26mm for UPB250 Load side : 24mm 24 t4 A Plug-in mounting 41 24 5 [Panel cut-out] [Drilling holes for mounting] [Plug-in connection part] 109 35 4- 6 mounting hole 26.5 15 23 [Mounting base] 96 4-M5 tap 31 4- 6 tap 37 30 15 92.5 110 35 70 105 190 179 113 144 175 190 35 107 30 31 M8 bolt 70 M8 mounting screw 22.5 26 Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch Shunt trip Under voltage trip 3 Left Right Handle [ Front ] Molded Case Circuit Breaker_ 171 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | Q-class (for nuclear power plant application) / HBL type 100AF, 85kA | 4 3 1 50 10 30 Rated current (A) Inst. trip current (A) 15 20 30 150±30 200±40 300±60 10 8 6 5 4 3 2 1 0.8 0.6 0.5 0.4 0.3 0.2 Percentage for rated current (%) Hour 4 3 Rated current (A) Inst. trip current (A) 60 75 100 600±120 750±150 1000±200 Derating rate for rated current (%) Minute 10 8 6 5 4 3 2 Tripping time 1 50 40 30 20 10 8 6 5 4 3 Second 2 1 0.8 0.6 0.5 0.4 0.3 Min. 0.1 0.08 0.06 0.05 0.04 0.03 Max. Current Installation of signal accessories 172 Under voltage trip 5000 6000 7000 8000 4000 3000 2500 2000 1500 1200 700 800 900 1000 600 500 400 300 250 200 150 125 100 105 Percentage for rated current (%) Handle 5000 4000 6000 7000 8000 3000 2500 2000 110 105 100 95 90 85 80 5 10 15 20 25 30 35 40 Ambient temperature (°C) 0.02 0.01 0.008 0.006 0.005 [ Front ] 115 0 0.2 Right 1500 60-100A 2 20 Left 1200 Current 1 50 10 30 3 700 800 900 1000 Percentage for rated current (%) Current Shunt trip Max. 500 300 250 200 100 105 5000 4000 6000 7000 8000 3000 2500 2000 1500 1200 700 800 900 1000 500 400 600 300 250 200 150 0.02 0.01 0.008 0.006 0.005 125 0.02 0.01 0.008 0.006 0.005 100 105 Min. 0.1 0.08 0.06 0.05 0.04 0.03 400 Max. 150 Min. 600 0.2 Trip alarm switch 400±80 500±100 10 8 6 5 4 3 2 10 8 6 5 4 3 Second 2 1 0.8 0.6 0.5 0.4 0.3 0.1 0.08 0.06 0.05 0.04 0.03 No. of Auxiliary poles switch Inst. trip current (A) 40 50 1 50 40 30 20 Tripping time Tripping time �HBL103UQ Rated current (A) 20 1 50 40 30 20 Second �HBL103U 40-50A 2 1 50 10 30 125 Minute 20 10 8 6 5 4 3 2 4 3 Hour 15-30A 2 Minute Hour Tripping & temperature derating curves 45 50 55 60 MCCB Dimensions ※ : Center line � The allowance of 1.5mm is given around the handle frame. : Handle center line (Unit: mm) Direct mounting 112 35 Terminal cover [with terminal bus bar*option] A M8 bolt Dimension A 144 165 146 Line side : 24mm Load side : 24mm A t4 [Connection conductor] [Terminal part] 23 (Max.) 10 86.5 Terminal cover [Drilling holes for mounting] [Panel cut-out] 3P 3P 24 9.5 8.5 9.5 0.7 tap M4 71 70 105 9 (Max.) 9 24 27.5 144 75.5 3P R5 35 M4×0.7 tapped hole 30 Molded Case Circuit Breaker_ 173 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | Q-class (for nuclear power plant application) / HBL type 100AF, 85kA / Motor protection | Tripping curves 4 100A Hour 2 1 30 20 14 10 Minute 6 4 2 1 Tripping time 30 20 �HBL103UM Instantaneous trip current (600-1300%) 10 5 2 �HBL103UMQ Min. Max. Second 1 0.5 0.2 0.1 0.05 0.04 0.03 0.02 7000 5000 3000 2000 400 600 700 800 900 100 1100 1200 1300 300 200 125 100 0.01 Percentage for rated current (%) Current Instantaneous trip current Rated current (A) 6 7 8 9 10 11 12 13 2.5 15 17.5 20 22.5 25 27.5 30 32.5 3.2 19.2 22.4 25.6 28.8 32 35.2 38.4 41.6 6.3 37.8 44.1 50.4 56.7 63 69.3 75.6 81.9 12.5 75 87.5 100 112.5 125 137.5 150 162.5 20 120 140 160 180 200 220 240 260 32 192 224 256 288 320 352 384 416 50 300 350 400 450 500 550 600 650 63 378 441 504 567 630 693 756 819 80 480 560 640 720 800 880 960 1040 100 600 700 800 900 1000 1100 1200 1300 Multiple for rated current ※ Tolerance for setting current: -20% - +30% Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch 3 Left Right Handle [ Front ] 174 Shunt trip Under voltage trip MCCB Dimensions ※ : Center line : Handle center line � The allowance of 1.5mm is given around the handle frame. (Unit: mm) Direct mounting 112 35 Terminal cover [with terminal bus bar*option] A M8 bolt Dimension A 144 165 146 Line side : 24mm Load side : 24mm A t4 [Connection conductor] [Terminal part] 23 (Max.) 10 86.5 Terminal cover [Drilling holes for mounting] [Panel cut-out] 3P 3P 24 9.5 8.5 9.5 0.7 tap M4 71 70 105 9 (Max.) 9 24 27.5 144 75.5 3P R5 35 M4×0.7 tapped hole 30 Molded Case Circuit Breaker_ 175 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | Q-class (for nuclear power plant application) / HBL type 225AF, 85kA | 25 1250 150 1500 20 175 1750 200 2000 225 2250 +375 -250 +450 -300 +525 -350 +600 -400 +675 -450 5000 Inst. trip current (A) 1 50 40 30 4000 Rated current (A) 55 60 10 8 6 5 4 3 2 10 8 6 5 4 3 2 Second �HBL203UQ 125-225A 2 1 50 40 30 20 Tripping time �HBL203U 4 3 3000 Minute Hour Tripping & temperature derating curves 1 0.8 0.6 0.5 0.4 0.3 Min. Max. 0.2 0.1 0.08 0.06 0.05 0.04 0.03 Percentage for rated current (%) Derating rate for rated current (%) Current 115 110 105 100 95 90 85 80 0 5 10 15 20 25 30 35 40 Ambient temperature (°C) Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch 3 Left Right Handle [ Front ] 176 Shunt trip Under voltage trip 45 50 8000 7000 6000 2500 1500 1200 700 800 900 1000 500 600 400 300 250 200 150 125 100 105 0.01 0.008 0.006 0.005 2000 0.02 MCCB Dimensions ※ : Center line : Handle center line � The allowance of 1.5mm is given around the handle frame. (Unit: mm) Direct mounting 112 35 Terminal cover [with terminal bus bar*option] A M8 bolt Dimension A 144 165 146 Line side : 26mm Load side : 24mm A t4 [Connection conductor] [Terminal part] 23 (Max.) 10 86.5 Terminal cover [Drilling holes for mounting] [Panel cut-out] 3P 3P 24 9.5 8.5 9.5 0.7 tap M4 71 70 105 9 (Max.) 9 24 27.5 144 75.5 3P R5 35 M4×0.7 tapped hole 30 Molded Case Circuit Breaker_ 177 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | Q-class (for nuclear power plant application) / HBL type 225AF, 85kA / Motor protection | Tripping curves Hour 4 225A 2 1 Minute 30 20 14 10 6 4 2 1 Tripping time 30 20 �HBL203UM Instantaneous trip current (500-1000%) 10 5 2 �HBL203UMQ Min. Max. Second 1 0.5 0.2 0.1 0.05 0.04 0.03 0.02 7000 5000 3000 2000 1500 500 600 700 800 900 1000 400 300 200 125 100 0.01 Percentage for rated current (%) Current Instantaneous trip current Rated current (A) 5 6 125 625 150 750 175 Multiple for rated current 7 8 9 10 750 875 1000 1125 1250 900 1050 1200 1350 1500 875 1050 1225 1400 1575 1750 200 1000 1200 1400 1600 1800 2000 225 1125 1350 1575 1800 2025 2250 ※ Tolerance for setting current: -20% - +30% Installation of signal accessories No. of Auxiliary poles switch Trip alarm switch 3 Left Right Handle [ Front ] 178 Shunt trip Under voltage trip MCCB Dimensions ※ : Center line : Handle center line � The allowance of 1.5mm is given around the handle frame. (Unit: mm) Direct mounting 112 35 Terminal cover [with terminal bus bar*option] A M8 bolt Dimension A 144 165 146 Line side : 26mm Load side : 24mm A t4 [Connection conductor] [Terminal part] 23 (Max.) 10 86.5 Terminal cover [Drilling holes for mounting] [Panel cut-out] 3P 3P 24 9.5 8.5 9.5 0.7 tap M4 71 70 105 9 (Max.) 9 24 27.5 144 75.5 3P R5 35 M4×0.7 tapped hole 30 Molded Case Circuit Breaker_ 179 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | Miniature type / Molded case circuit breaker | Tripping & temperature derating curves �UBD30L Max. Min. Second �UBD30H Derating rate for rated current (%) Tripping time Minute 15-30A Instantaneous trip (1100-1700%) Ambient temperature (°C) Max. total breaking time Multiple for rated current (times) Current Dimensions ※ Direct mounting : Center line : Handle center line UBD30L UBD30H HL C L C L 42 54.6 22 35 60 76 5.2 6 76 5.2 30 8 5.5 54.6 22 35 70 50 82.5 82.5 70 50 HL 42 � The allowance of 1.5mm is given around the handle frame. [Drilling holes for mounting] [Panel cut-out] [Terminal part] 10.7 6.2 6.2 10.7 70 52 5.2 5.2 Line side 37 180 Load side (Unit: mm) MCCB Tripping & temperature derating curves 240 15-30A 120 Minute 60 10 1 40 Tripping time �UMB30R Derating rate for rated current (%) 2 Max. 20 10 6 4 2 Second Min. 1 150 100 50 0 10 20 30 40 50 Ambient temperature (°C) 0.2 0.1 Instantaneous trip (800-2000%) Max. total breaking time 0.02 0.01 1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 100 Multiple for rated current (times) Current Dimensions ※ : Center line : Handle center line � The allowance of 1.5mm is given around the handle frame. (Unit: mm) Direct mounting 33 [Terminal part] 42 20 11.3 Line side 68� 8.2 14.5 Load side 57 [Panel cut-out] 59 38 [Drilling holes for mounting] 11.3 M5×11 6.8 70 56 36 6.8 8.2 35 Molded Case Circuit Breaker_ 181 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | Miniature type / Molded case circuit breaker | Tripping & temperature derating curves 15-50A Minute Tripping time �UMB30S �UMB50S Derating rate for rated current (%) Max. Second Min. Ambient temperature (°C) Instantaneous trip (800-2000%) Max. total breaking time Multiple for rated current (times) Current Dimensions ※ : Center line : Handle center line � The allowance of 1.5mm is given around the handle frame. (Unit: mm) Direct mounting IEC 35mm DIN-rail 80 35 6 10.5 5 Line side 32 Load side 30 10.5 60 66 67.5 76 19 35 [Drilling holes for mounting] 35 [Panel cut-out] M4 or �5 70 52 R2 182 M5×12 6 20.5 70 50 68 80 20.5 [Terminal part] MCCB Tripping & temperature derating curves 15-50A Minute Derating rate for rated current (%) Tripping time �UMB30H Max. �UMB50H Second Min. Ambient temperature (°C) Instantaneous trip (800-1200%) Max. total breaking time Multiple for rated current (times) Current Dimensions ※ : Center line � The allowance of 1.5mm is given around the handle frame. : Handle center line (Unit: mm) Direct mounting M5×12 80 35 68 50 18.5 [Terminal part] 6 6 10.5 6 5 Line side 32 Load side 30 10.5 60 19 트립테스트 버튼 66 35 67.5 76 [Drilling holes for mounting] [Panel cut-out] 35 M4 or �5 70 R2 52 70 47.5 IEC 35mm DIN-rail Molded Case Circuit Breaker_ 183 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | Miniature type / Molded case circuit breaker | Tripping & temperature derating curves 3-30A Max. Tripping time Second �UDB30S �UDB30H �UDB50S Min. Instantaneous trip (800-1200%) Derating rate for rated current (%) Minute Max. total breaking time �UDB50H Ambient temperature (°C) �UDB100S �UDB100H Multiple for rated current (times) Current 40-100A Max. Tripping time Second Min. Instantaneous trip (800-1200%) Max. total breaking time Multiple for rated current (times) Current Installation of signal accessories Trip alarm switch Shunt trip 3 Left Right Handle [ Front ] 184 Auxiliary switch Ambient temperature (°C) No. of poles Derating rate for rated current (%) Minute ※ - In case of 2P, all signal accessories shall be installed in left side of breaker. - SHT is not applicable to 2P. MCCB Dimensions ※ Direct mounting : Center line � The allowance of 1.5mm is given around the handle frame. : Handle center line (Unit: mm) UDB30, UDB50 IEC 35mm DIN-rail 13 13 Trip button 35 97.5 64 80 96 50 9 25 64 80 96 50 9 25 Mounting hole 19.1 19.1 4.5 Trip button 25 50 50 53 60 65 80 50 75 2P 3P [Terminal part] 8 8 M5×12 Line side 32 Load side 30 17 [Drilling holes for mounting] [Panel cut-out] M4 or �5 74 25 M4 or �5 49 R2 52 52 80-84 R2 2P Direct mounting 3P 2P 3P UDB100 Mounting hole IEC 35mm DIN-rail 19.1 88 19.1 M8×14 35 97.5 64 80 50 9 25 [Terminal part] 4.5 Trip button [Drilling holes for mounting] [Panel cut-out] M4 or �5 74 Line side 32 Load side 30 17 50 53 60 65 80 50 75 25 80-84 52 R2 Molded Case Circuit Breaker_ 185 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | Miniature type / Earth leakage circuit breaker | Tripping & temperature derating curves 15-30A Minute Derating rate for rated current (%) Tripping time �UGD30L Max. Second �UGD30H Min. Instantaneous trip (1100-1700%) Ambient temperature (°C) Max. total breaking time Multiple for rated current (times) Current Dimensions ※ Direct mounting : Center line UGD30H 82.5 70 50 82.5 70 50 UGD30L 42 54.6 22 35 5.2 60 76 76 5.2 30 6 8 5.5 54.6 22 35 42 � The allowance of 1.5mm is given around the handle frame. : Handle center line [Drilling holes for mounting] [Panel cut-out] [Terminal part] 10.7 6.2 6.2 10.7 70 52 5.2 5.2 Line side 37 186 Load side (Unit: mm) MCCB Tripping & temperature derating curves 240 15-30A 120 Minute 60 10 1 40 Tripping time �UMG30R Derating rate for rated current (%) 2 Max. 20 10 6 4 2 Second Min. 1 150 100 50 0 10 20 30 40 50 Ambient temperature (°C) 0.2 0.1 Instantaneous trip (800-2000%) Max. total breaking time 0.02 0.01 1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 100 Multiple for rated current (times) Current Dimensions ※ : Center line : Handle center line � The allowance of 1.5mm is given around the handle frame. (Unit: mm) Direct mounting 33 42 20 [Terminal part] 6.8 68� Line side M5×11 6.8 부하측�(LOAD) 11.3 70 56 36 전원측�(LINE) 11.3 8.2 14.5 8.2 Load side 57 [Panel cut-out] 59 38 [Drilling holes for mounting] 35 Molded Case Circuit Breaker_ 187 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | Miniature type / Earth leakage circuit breaker | Tripping & temperature derating curves 15-50A Minute Tripping time �UMG30S �UMG50S Derating rate for rated current (%) Max. Second Min. Ambient temperature (°C) Instantaneous trip (800-2000%) Max. total breaking time Multiple for rated current (times) Current Dimensions ※ : Center line � The allowance of 1.5mm is given around the handle frame. : Handle center line Direct mounting IEC 35mm DIN-rail [Terminal part] 80 35 6 6 20.5 70 50 68 80 20.5 M5×12 10.5 5 Line side 32 Load side 30 10.5 60 66 67.5 76 19 35 Earth leakage test button [Drilling holes for mounting] 35 [Panel cut-out] M4 or �5 188 70 52 R2 (Unit: mm) MCCB Tripping & temperature derating curves 15-50A Minute Derating rate for rated current (%) Tripping time �UMG30H �UMG50H Max. Second Min. Ambient temperature (°C) Instantaneous trip (800-1200%) Max. total breaking time Multiple for rated current (times) Current Dimensions ※ : Center line � The allowance of 1.5mm is given around the handle frame. : Handle center line (Unit: mm) Direct mounting IEC 35mm DIN-rail Earth leakage test button 80 68 35 18.5 M5×12 50 70 47.5 [Terminal part] 6 6 6 10.5 5 Line side 32 Load side 30 10.5 60 Trip button 19 66 35 67.5 76 [Drilling holes for mounting] 35 [Panel cut-out] M4 or �5 70 52 R2 Molded Case Circuit Breaker_ 189 U-Series / Molded Case Circuit Breaker Characteristic Curves & Dimensions | Miniature type / Earth leakage circuit breaker | Tripping & temperature derating curves 3-30A Max. Tripping time Second �UDG30S �UDG30H Min. Instantaneous trip (800-1200%) �UDG50S �UDG50H Derating rate for rated current (%) Minute Ambient temperature (°C) Max. total breaking time �UDG100S �UDG100H Multiple for rated current (times) Current 40-100A Max. Tripping time Second Min. Instantaneous trip (800-1200%) Max. total breaking time Multiple for rated current (times) Current Installation of signal accessories Trip alarm switch 3 Right Left Handle [ Front ] 190 No. of Auxiliary poles switch Derating rate for rated current (%) Minute ※ - In case of 2P, all signal accessories shall be installed in left side of breaker. Ambient temperature (°C) MCCB Dimensions ※ : Handle center line � The allowance of 1.5mm is given around the handle frame. (Unit: mm) UGD30, UGD50 35 97.5 50 9 25 13 13 Trip button IEC 35mm DIN-rail Earth leakage indicator Mounting hole 64 80 96 50 9 25 Earth leakage indicator 64 80 96 Direct mounting : Center line 19.1 19.1 Earth leakage test button Trip button 25 50 4.5 Earth leakage test button 50 53 60 65 80 50 75 2P 3P [Terminal part] 8 8 M5×12 17 [Drilling holes for mounting] [Panel cut-out] 74 49 M4 or �5 80-84 52 52 2P 3P 80-84 R2 R2 Direct mounting 25 M4 or �5 2P 3P UGD100 Earth leakage indicator Mounting hole IEC 35mm DIN-rail [Terminal part] 35 97.5 64 80 96 50 9 25 M8×14 88 19.1 19.1 4.5 Earth leakage test button Line side 32 Load side 30 17 50 53 60 65 80 50 75 [Drilling holes for mounting] [Panel cut-out] M4 or �5 74 25 80-84 R2 52 Trip button Molded Case Circuit Breaker_ 191 U-Series / Molded Case Circuit Breaker Accessories < Accessories for UAB100 > | Signal accessories | �auxiliary switch �trip alarm switch �shunt trip �under voltage trip | Operating accessories | �operating handle (surface and extended type) �motor operator �mechanical interlock �extension handle | Mounting accessories | �DIN-rail adaptor �mounting base for plug-in mounting Auxiliary switch [ AUX ] | Terminal accessories | �terminal bus bar �cage terminal block �terminal cover �interpole barrier Trip alarm switch [ ALT ] | Portable test equipment | �MCCB trip unit tester Surface type operating handle [ TFG ] Extended type operating handle [ TFH ] Motor operator [ MOT ] ※ The applicable accessories of each MCCB are not same as above. For exact application to each MCCB, please reter to next pages. 194 MCCB Cage terminal block [ CTB ] Terminal cover [ TCF ] Interpole barrier [ TQQ ] DIN-rail adaptor [ DRA ] Plug-in mounting base [ TDM ] Shunt trip [ SHT ] Under voltage trip [ UVT ] Cage terminal block [ CTB ] Terminal cover [ TCF ] Interpole barrier [ TQQ ] Molded Case Circuit Breaker_ 195 U-Series / Molded Case Circuit Breaker Signal Accessories �Signal accessories adopts cassette type assembly method, so they can be easily installed and removed. Auxiliary AUX - Electrically indicates ON and OFF status of breaker Shunt trip SHT - Electrically trips breaker at remote place 196 Trip alarm switch ALT - Electrically indicates TRIP status of breaker Under voltage trip UVT - Automatically trips breaker when control voltage drops below predetermined value MCCB | Installation and wiring of signal accessories | Item Installation 3 pole Wiring 2 pole 1EA of 1ab type AUX 2EA of 1ab type AUX Auxiliary switch [AUX] 3EA of 1ab type AUX 4EA of 1ab type AUX Trip alarm switch [ALT] Limit switch for coil protecton 1) for SHT 10A H, SHT 10B H, SHT 20C H Shunt trip [SHT] 2) Under voltage trip [UVT] ※ - For detail installation to each MCCB model, please refer to “Characteristic curves & Dimensions” from page 140 to 191. 1) Common for AC200-480V. Applicable for SHT 10A H, SHT 10B H and SHT 20C H only. 2) The coil is continuously energized, so that limit switch is not required. | Operation of AUX and ALT | MCCB Status Auxiliary switch [AUX] Trip alarm switch [ALT] ON OFF TRIP Molded Case Circuit Breaker_ 197 U-Series / Molded Case Circuit Breaker Signal Accessories | Auxiliary switch (AUX) and trip alarm switch (ALT) | Applicable MCCB UAB30C, UAB30R, UAB50C, UAB50R, UAB60C, UAB60R, UAB100C / UAD50C UAB50S, UAB50H, UAB100R, UAB100S / UAD50S, UAD100R UCB50R, UCB100R, UCB100S / UCD100S UCB250R, UCB250S, UCB250N / UCD250S UCB50H, UCB50L, UCB100H, UCB100L, UCB160H, UCB160L, UCB250H, UCB250L / UCD50H, UCD100H, UCD160H, UCD250H UCB400R, UCB400S, UCB400H, UCB400L, UCB630R, UCB630S, UCB630H, UCB630L, UCB800R, UCB800S, UCB800H, UCB800L / UCD400S, UCD630S, UCD800S UCB1000S, UCB1000L, UCB1250S, UCB1250L / UCD1000S, UCD1250S UCB1600S UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X / UPD400S, UPD630S HBL103U, HBL103UM, HBL203U, HBL203UM, HBL103UQ, HBL103UMQ, HBL203UQ, HBL203UMQ1) UDB30S, UDB30H, UDB50S, UDB50H, UDB100S, UDB100H / UDG30S, UDG30H, UDG50S, UDG50H, UDG100S, UDG100H Auxiliary switch (AUX) Order code Trip alarm switch (ALT) Specification Order code AUX 10A R1 AUX 10A R2 AUX 10UA R1 AUX 10UA L1 AUX 10B L1 AUX 20C L1 1ab, Right-hand-side 2ab, Right-hand-side 1ab, Right-hand-side 1ab, Left-hand-side 1ab, Left-hand-side 1ab, Left-hand-side ALT 10A R1 1ab, Right-hand-side ALT 10UA R1 ALT 10UA L1 ALT 10B L1 ALT 20C L1 1ab, Right-hand-side 1ab, Left-hand-side 1ab, Left-hand-side 1ab, Left-hand-side AUX 12FG R1 1ab, Right-hand-side ALT 12FG R1 1ab, Right-hand-side AUX 12FG R2 2ab, Right-hand-side ALT 12FG L1 1ab, Left-hand-side AUX 46D L1 1ab, Left-hand-side ALT 46D L1 1ab, Left-hand-side AUX 80NE R1 AUX 80NE R2 AUX 80NE R3 AUX 160NE R1 AUX 160NE R2 1ab, Right-hand-side 2ab, Right-hand-side 3ab, Right-hand-side 1ab, Right-hand-side 2ab, Right-hand-side ALT 80NE R1 1ab, Right-hand-side - - AUX 12UP R1 1ab, Right-hand-side ALT 12UP L1 1ab, Left-hand-side AUX 46UP L1 1ab, Left-hand-side ALT 46UP R1 1ab, Right-hand-side AUX 12UP R1 1ab, Right-hand-side ALT 12UP L1 1ab, Left-hand-side AUX 10UD R1 1ab, Right-hand-side ALT 10UD R1 ALT 10UD R2 Specification Category MCCB MB 1ab, Right-hand-side for 2 pole 1ab, Right-hand-side for 3 pole ※1) Signal accessories for HBL type shall be installed in breaker before ex-working. | Shunt trip (SHT) | Applicable MCCB UAB30C, UAB30R, UAB50C, UAB50R, UAB60C, UAB60R, UAB100C / UAD50C UAB50S, UAB50H, UAB100R, UAB100S / UAD50S, UAD100R UCB50R, UCB100R, UCB100S / UCD100S UCB250R, UCB250S, UCB250N / UCD250S UCB50H, UCB50L, UCB100H, UCB100L, UCB160H, UCB160L, UCB250H, UCB250L / UCD50H, UCD100H, UCD160H, UCD250H UCB400R, UCB400S, UCB400H, UCB400L, UCB630R, UCB630S, UCB630H, UCB630L, UCB800R, UCB800S, UCB800H, UCB800L / UCD400S, UCD630S, UCD800S UCB1000S, UCB1000L, UCB1250S, UCB1250L / UCD1000S, UCD1250S UCB1600S UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X / UPD400S, UPD630S HBL103U, HBL103UM, HBL203U, HBL203UM, HBL103UQ, HBL103UMQ, HBL203UQ, HBL203UMQ2) UDB30S, UDB30H, UDB50S, UDB50H, UDB100S, UDB100H Order code / Exciting current (peak value) DC24V DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V SHT 10A A SHT 10A C SHT 10A F SHT 10A H 5.2A 1.1A 0.76A 0.28A SHT 10UA A SHT 10UA C SHT 10UA F SHT 10UA H SHT 10UA B SHT 10UA D 5.7A 1.2A 0.88A 0.42A 0.42A 0.42A SHT 10B A SHT 10B C SHT 10B F SHT 10B H 5.2A 2.2A 0.76A 0.4A SHT 20C A SHT 20C C SHT 20C F SHT 20C H 5.2A 2.2A 0.76A 0.4A SHT 12FG A SHT 12FG F SHT 12FG H SHT 12FG B SHT 12FG D 5.2A 2.2A 0.76A 0.4A 0.4A 0.4A SHT 46D A SHT 46D C SHT 46D F SHT 46D H SHT 46D B SHT 46D D 0.01A 0.01A 0.012A 0.011A 0.01A 0.01A SHT 120NE A SHT 120NE C SHT 120NE F SHT 120NE H SHT 120NE B SHT 120NE D 2A 0.11A 0.24A 0.23A 0.23A 0.23A SHT 160NE A SHT 160NE C SHT 160NE F SHT 160NE H SHT 160NE B1) 2A 1A 0.76A 0.4A 0.35A SHT 12UP A SHT 12UP C SHT 12UP F SHT 12UP H SHT 12UP B SHT 12UP D 0.023A 0.023A 0.023A 0.023A 0.023A 0.023A SHT 46UP A 0.023A SHT 12UP A 0.023A SHT 10UD A 1.65A SHT 46UP C 0.023A SHT 12UP C 0.023A SHT 10UD C 0.36A SHT 46UP F 0.023A SHT 12UP F 0.023A SHT 10UD F 0.4A SHT 46UP H 0.023A SHT 12UP H 0.023A SHT 10UD H 0.2A SHT 46UP B 0.023A SHT 12UP B 0.023A SHT 10UD B 0.08A SHT 46UP D 0.023A SHT 12UP D 0.023A SHT 10UD D 0.1A ※- The permissible operating voltage: 85-110% of rated voltage for AC , 75-125% for DC. 1) SHT 160NE B is applicable for AC380V only. 2) Signal accessories for HBL type shall be installed in breaker before ex-working. 198 SHT 12FG C Category MCCB MB MCCB | Under voltage trip (UVT) | Order code Applicable MCCB DC24V UAB30C, UAB30R, UAB50C, UAB50R, UAB60C, UAB60R, UAB100C / UAD50C UAB50S, UAB50H, UAB100R, UAB100S / UAD50S, UAD100R UCB50R, UCB100R, UCB100S / UCD100S UCB250R, UCB250S, UCB250N / UCD250S UCB50H, UCB50L, UCB100H, UCB100L, UCB160H, UCB160L, UCB250H, UCB250L / UCD50H, UCD100H, UCD160H, UCD250H UCB400R, UCB400S, UCB400H, UCB400L, UCB630R, UCB630S, UCB630H, UCB630L, UCB800R, UCB800S, UCB800H, UCB800L / UCD400S, UCD630S, UCD800S UCB1000S, UCB1000L, UCB1250S, UCB1250L / UCD1000S, UCD1250S UCB1600S UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X / UPD400S, UPD630S HBL103U, HBL103UM, HBL203U, HBL203UM, HBL103UQ, HBL103UMQ, HBL203UQ, HBL203UMQ2) �UVT 10A J DC100-110V AC100-120V AC200-230V AC380-415V AC440-480V �UVT 10A L � UVT 10A N �UVT 10A P �UVT 10A Q �UVT 10A R UVT 10UA J UVT 10UA L UVT 10UA N UVT 10UA P UVT 10UA Q UVT 10UA R UVT 10B J UVT 20C J UVT 10B L UVT 20C L UVT 10B N UVT 20C N UVT 10B P UVT 20C P UVT 10B Q UVT 20C Q UVT 10B R UVT 20C R UVT 12FG J UVT 12FG L UVT 12FG N UVT 12FG P UVT 12FG Q UVT 12FG R �UVT 46D J �UVT 46D L �UVT 46D N �UVT 46D P Category �UVT 46D Q �UVT 46D R MCCB MB UVT 120NE J UVT 120NE L UVT 120NE N UVT 120NE P UVT 120NE Q - - - UVT 120NE R UVT 160NE P UVT 160NE Q1) - �UVT 12UP J �UVT 12UP L � UVT 12UP N �UVT 12UP P �UVT 12UP Q �UVT 12UP R �UVT 46UP J �UVT 46UP L � UVT 46UP N �UVT 46UP P �UVT 46UP Q �UVT 46UP R �UVT 12UP J �UVT 12UP L � UVT 12UP N �UVT 12UP P �UVT 12UP Q �UVT 12UP R ※- The permissible operating voltage: 85-110% of rated voltage for AC, 85~125% for DC. The tripping voltage: 20-70% of rated voltage. � Reset is possible without power. 1) UVT 160NE Q is applicable for AC380V only. 2) Signal accessories for HBL type shall be installed in breaker before ex-working. �UVT controller is supplied as standard for UVT 10A, UVT 10B, UVT 20C, UVT 12FG, UVT 46D J, UVT 12UP and UVT 46UP type. Fixing hole (R/H M4 X L11 + P/W + S/W) U2 88 100 16 15 18 15 16 8 16 ON MCCB U1 UC2 (-) 16.5 Mounting hole( 4.5) (R/H M4 X L9 + P/W + S/W) 22 UC1 (+) OFF Terminal screw M3.5 4 63 56 45 UVT controller Supportor [ Wiring ] [ Dimensions ] ※ Terminal U1 an U2 are connected by the cable of vw-1, 22AWG (0.324㎟×700㎜). Different cables are available on request. Molded Case Circuit Breaker_ 199 U-Series / Molded Case Circuit Breaker Operating Accessories � Operating accessories offers convenience and safety in operation of breaker. Operating handle TFG, TFH - Enables manual operation of breaker without panel door-open - Offers panel door-lock and reverse interlock function - Satisfies IP54 Surface type / TFG Extended type / TFH - Useful in case that panel door is far from breaker - Mechanism part is installed on front of breaker and connected with operating part by shaft Motor operator MOT PLD - Locks the breaker in OFF position 200 MIF - Mechanically prevents simultaneous closing of two breakers - Enables automatic remote ON and OFF operation as well as manual operation - Applied to electric supervision and control system - Equips an emergency trip button in all range Padlock plate Mechanical interlock Extension handle THA - Reduces strength in operation of breaker MCCB | Operating handle (TFG/TFH) | Surface type (TFG) Applicable MCCB UAB30C, UAB30R, UAB50C, UAB50R, UAB60C, UAB60R, UAB100C / UAD50C UAB50S, UAB50H, UAB100R, UAB100S / UAD50S, UAD100R UCB50R, UCB100R, UCB100S / UCD100S UCB250R, UCB250S, UCB250N / UCD250S UCB50H, UCB50L, UCB100H, UCB100L / UCD50H, UCD100H UCB160H, UCB160L, UCB250H, UCB250L / UCD160H, UCD250H UCB400R, UCB400S, UCB400H, UCB400L, UCB630R, UCB630S, UCB630H, UCB630L, UCB800R, UCB800S, UCB800H, UCB800L / UCD400S, UCD630S, UCD800S UCB1600S UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X / UPD400S, UPD630S HBL103U, HBL103UM, HBL203U, HBL203UM HBL103UQ, HBL103UMQ, HBL203UQ, HBL203UMQ Extended type (TFH) S type L type Right1) Left1) Upper1) Left1) Upper1) power supply power supply power supply power supply power supply type type type type type S type L type TFG 10AL L4 TFH 10AS TFH 10AL TFG 10UAS U4 TFG 10UAS R4 TFG 10UAS L4 TFG 10UAL U4 TFG 10UAL L4 TFH 10UAS TFH 10UAL TFG 10BS U4 TFG 10BS R4 TFG 10BS L4 TFG 10BL U4 TFG 10BL L4 TFG 20CS U4 TFG 20CS R4 TFG 20CS L4 TFG 20CL U4 TFG 20CL L4 TFH 10BS TFH 20CS TFH 10BL TFH 20CL TFG 10UFS U4 TFG 10UFS R4 TFG 10UFS L4 TFG 10UFL U4 TFG 10UFL L4 TFH 10UFS TFH 10UFL TFG 20UGS U4 TFG 20UGS R4 TFG 20UGS L4 TFG 20UGL U4 TFG 20UGL L4 TFH 20UGS TFH 20UGL TFG 46DS U2 TFG 46DS R2 TFG 46DS L2 TFG 10AS U4 TFG 10AS R4 TFG 10AS L4 TFG 10AL U4 - - TFH 46DS - - - TFH 160NE - TFG 12UPS U4 TFG 12UPS R4 TFG 12UPS L4 TFG 12UPL U4 TFG 12UPL L4 TFH 12UPS TFH 12UPL TFG 46UPS U2 TFG 46UPS R2 TFG 46UPS L2 TFH 46UPS - - TFH 20U TFH 20UQ - - - - - - - - TFG 20U U4 TFG 20U L4 TFG 20UQ U4 TFG 20UQ L4 ※- In case of surface type (TFG), there are three types for diverse panel door-lock application, above mentioned codes are standard type. For detail, please refer to following explanation. 1) Upper, right and left indicates the power supply direction of MCCB. Power supply direction of MCCB �Surface type (TFG) operating handles are divided into three types by power supply direction of MCCB. Power (Line side) Power (Line side) Power (Line side) MCCB MCCB MCCB [Upper power supply type] [Right power supply type] [Left power supply type] Panel door-lock �Surface type (TFG) operating handles offer four options in panel door-lock application. - OFF OPEN type: Panel door opens when operating handle is in OFF position. Indicating code (last digit of full order code) is 1. ex. TFG 10AS U1 - OFF OPEN type with reverse interlock: Panel door opens when operating handle is in OFF position. Reverse interlock keeps MCCB not to be "ON" when panel door opens. This is standard type for 400-800AF MCCB and indicating code (last digit of full order code) is 2. ex.TFG 46DS U2 - RESET OPEN type: Panel door opens when operating handle is in RESET position. Indicating code (last digit of full order code) is 3. ex.TFG 10AS U3 - RESET OPEN type with reverse interlock: Panel door opens when operating handle is in RESET position. Reverse interlock keeps MCCB not to be “ON” when panel door opens. This is standard type for 30-250AF MCCB and indicating code (last digit of full order code) is 4. ex. TFG 46DS U4 �When panel door is required to open in ON position of operating handle, please turn the RELEASE knob to indicated direction and open the panel door. �For more operating function, please refer to following pages. Molded Case Circuit Breaker_ 201 U-Series / Molded Case Circuit Breaker Operating Accessories Operation �Operating direction - Turn the handle in a clockwise direction for ON. �Operation in panel door-closed - MCCB ON: Turn the handle to ON position. (Fig. 1) MCCB OFF: Turn the handle to OFF position. (Fig. 2) MCCB TRIP: When MCCB trips, handle turns to TRIP position automatically. After MCCB trips, turn the handle to RESET position first and turn to ON position for MCCB ON. (Fig. 3 and Fig. 1) - When panel door is required to open in ON position of operating handle, please turn the RELEASE knob to indicated direction and open the panel door. (Fig. 4) �Lock and release of panel door - When MCCB is in ON, OFF and TRIP status, both operating handle and panel door are locked. - When MCCB is in OFF and TRIP status, panel door can be opened by turning the handle to RESET position. (Fig. 3) - Panel door shall be locked automatically when you close the door in MCCB ON status. Please turn the handle to ON position before closing the door. �Lock of operating handle - If required, you can lock operating handle in ON or OFF position with padlock (� 6-8 for S type, � 4-6 for L type). Padlock is not supplied. (Fig. 5) - When MCCB trips, handle turns to TRIP position automatically. �Handle position shall be same with MCCB position (ON, OFF, TRIP) before closing the panel door. Fig.1 Fig.2 Fig.3 Fig.4 Fig.5 Trip button [ S type ] Fig.1 Fig.2 Fig.3 Fig.4 [ L type ] 202 Fig.5 MCCB Dimensions and standard order code / Surface type (TFG) �30-250AF S type [ Upper power supply type ] Panel door Line side 59 A 37 44 Handle center line 59 MCCB center line [ Right power supply type ] B 8 C Handle center line MCCB center line Panel door 37 44 A 59 Line side A 59 8 Handle center line C MCCB center line Panel door Line side 59 37 4- A 4 [ Left power supply type ] B 59 A 8 Order code Applicable MCCB UAB30C, UAB30R, UAB50C, UAB50R, UAB60C, UAB60R, UAB100C / UAD50C UAB50S, UAB50H, UAB100R, UAB100S / UAD50S, UAD100R UCB50R, UCB100R, UCB100S / UCD100S UCB250R, UCB250S, UCB250N / UCD250S UCB50H, UCB50L, UCB100H, UCB100L / UCD50H, UCD100H UCB160H, UCB160L, UCB250H, UCB250L / UCD160H, UCD250H UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S Upper power supply type Right power supply type C B Dimensions (mm) Left power supply type Category A B C TFG 10AS U4 TFG 10AS R4 TFG 10AS L4 7 43 56 TFG 10UAS U4 TFG 10UAS R4 TFG 10UAS L4 0 43 56 TFG 10BS U4 TFG 20CS U4 TFG 10BS R4 TFG 20CS R4 TFG 10BS L4 TFG 20CS L4 9 9 47 47 56 56 TFG 10UFS U4 TFG 10UFS R4 TFG 10UFS L4 9 47 56 TFG 20UGS U4 TFG 20UGS R4 TFG 20UGS L4 9 47 56 TFG 12UPS U4 TFG 12UPS R4 TFG 12UPS L4 16.25 41 87 MCCB MB Molded Case Circuit Breaker_ 203 U-Series / Molded Case Circuit Breaker Operating Accessories �30-250AF L type [ Upper power supply type ] Panel door B 1.2-3.2 4-Ø8 50 5 55 55 60 88 100 A Handle center line MCCB center line 88 100 25 4-M4 bolt hole [ Left power supply type ] Panel door Handle center line B MCCB center line A A 1.2-3.2 88 100 25 88 100 4-Ø8 MCCB center line Handle center line 50 60 55 55 Dimensions (mm) Order code Applicable MCCB UAB30C, UAB30R, UAB50C, UAB50R, UAB60C, UAB60R, UAB100C / UAD50C UAB50S, UAB50H, UAB100R, UAB100S / UAD50S, UAD100R UCB50R, UCB100R, UCB100S / UCD100S UCB250R, UCB250S, UCB250N / UCD250S UCB50H, UCB50L, UCB100H, UCB100L / UCD50H, UCD100H UCB160H, UCB160L, UCB250H, UCB250L / UCD160H, UCD250H UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S 204 Upper power supply type Left power supply type Category A B TFG 10AL U4 TFG 10AL L4 5 106-111 TFG 10UAL U4 TFG 10UAL L4 5 106-111 TFG 10BL U4 TFG 20CL U4 TFG 10BL L4 TFG 20CL L4 9 9 111-116 111-116 TFG 10UFL U4 TFG 10UFL L4 9 111-116 TFG 20UGL U4 TFG 20UGL L4 9 111-116 TFG 12UPL U4 TFG 12UPL L4 14.5 136-140 MCCB MB MCCB �400-630AF S type [ Upper power supply type ] Handle center line 5 4- Line side MCCB center line 100 [ Right power supply type ] 100 A 10 5 100 Panel door 55 5~10 Handle center line 55 Panel door 5 15 10 5 Line side 100 4- A 100 B 100 MCCB center line 5~10 B [ Left power supply type ] Handle center line 5 55 Line side 4- 15 100 10 5 100 A Panel door 100 MCCB center line 5~10 Dimensions (mm) Order code Applicable MCCB Upper power supply type B Category Right power supply type Left power supply type A B TFG 46DS R2 TFG 46DS L2 0 222 UCB400R, UCB400S, UCB400H, UCB400L, UCB630R, UCB630S, UCB630H, UCB630L, TFG 46DS U2 UCB800R, UCB800S, UCB800H, UCB800L MCCB / UCD400S, UCD630S, UCD800S MB UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X TFG 46UPS U2 TFG 46UPS R2 TFG 46UPS L2 13 234 / UPD400S, UPD630S Molded Case Circuit Breaker_ 205 U-Series / Molded Case Circuit Breaker Operating Accessories Dimensions and standard order code / Extended type (TFH) 4 �30-250AF S type 37 4- A Panel door 227 59 5 59 15 15 247 Applicable MCCB 38 B C Dimensions (mm) Order code Category A B C TFH 10AS 384-479 43 56 UAB50S, UAB50H, UAB100R, UAB100S / UAD50S, UAD100R TFH 10UAS 384-479 43 56 UCB50R, UCB100R, UCB100S / UCD100S TFH 10BS 388-383 47 56 UCB250R, UCB250S, UCB250N / UCD250S TFH 20CS 388-383 47 56 UCB50H, UCB50L, UCB100H, UCB100L / UCD50H, UCD100H TFH 10UFS 388-383 47 56 UCB160H, UCB160L, UCB250H, UCB250L / UCD160H, UCD250H TFH 20UGS 388-383 47 56 TFH 12UPS 419-414 41 87 UAB30C, UAB30R, UAB50C, UAB50R, UAB60C, UAB60R, UAB100C / UAD50C UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S 206 MCCB MB MCCB �30-250AF L type B [ Upper power supply ] Panel door C 1.2-3.2 Handle center line 77 50 19 80 77 A 0 R1 80 MCCBcenter line D 4-M4 bolt hole Panel door [ Left power supply ] B 1.2-3.2 Handle center line 50 C 19 80 77 0 R1 77 A 80 Handle center line MCCBcenter line D 4-M4 bolt hole Applicable MCCB Dimensions (mm) Order code UAB30C, UAB30R, UAB50C, UAB50R, UAB60C, UAB60R, UAB100C / UAD50C UAB50S, UAB50H, UAB100R, UAB100S / UAD50S, UAD100R UCB50R, UCB100R, UCB100S / UCD100S UCB250R, UCB250S, UCB250N / UCD250S UCB50H, UCB50L, UCB100H, UCB100L / UCD50H, UCD100H UCB160H, UCB160L, UCB250H, UCB250L / UCD160H, UCD250H UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S Category A B C D TFH 10AL TFH 10UAL TFH 10BL TFH 20CL TFH 10UFL TFH 20UGL 5 5 9 9 9 9 210-360 210-360 210-360 210-360 210-360 210-360 160 160 164 164 164 164 106 106 110 110 110 110 TFH 12UPL 14.5 210-360 186 135 MCCB MB �400-630AF S type 5-10 Panel door 250 125 A 10 5 100 4- 5 55 100 A Applicable MCCB Order code Dimensions (mm) A UCB400R, UCB400S, UCB400H, UCB400L, UCB630R, UCB630S, UCB630H, UCB630L, UCB800R, UCB800S, UCB800H, UCB800L / UCD400S, UCD630S, UCD800S TFH 46DS 428 UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X / UPD400S, UPD630S TFH 46UPS 440 Category MCCB MB Molded Case Circuit Breaker_ 207 U-Series / Molded Case Circuit Breaker Operating Accessories Dimensions and standard order code / Q-class (for nuclear power plant application) �Surface type (TFG) [ Upper power supply type ] Panel door Max. 140 - Min. 136 35 Line Handle center line 1.2-3.2 87.5 14.5 88 100 14.5 A 58.5 4-� 8 88 MCCB center line 100 5.5 4-M4 bolt hole B C D [ Left power supply type ] Panel door Handle center line MCCB center line Handle center line MCCB center line Max. 140 - Min. 136 1.2-3.2 4-� 8 88 100 35 Line A 88 58.5 87.5 100 73 73 5.5 B C D 14.5 Dimensions (mm) Order code Applicable MCCB Upper power supply type Left power supply type Category A B C D HBL103U, HBL103UM, HBL203U, HBL203UM TFG 20U U4 TFG 20U L4 14.5 51.5 78 129.5 HBL103UQ, HBL103UMQ, HBL203UQ, HBL203UMQ TFG 20UQ U4 TFG 20UQ L4 14.5 51.5 78 129.5 MCCB 208 MB MCCB �Extended type (TFH) [ Upper power supply ] Panel door Handle center line 1.2-3.2 19 50 80 73 87.5 77 14.5 80 14.5 73 58.5 0 R1 77 210-360 188 35 Line MCCB center line 35 135 4-M4 bolt hole [ Left power supply ] Panel door 210-360 1.2-3.2 Handle center line MCCB center line 188 19 35 Line 80 50 77 0 R1 77 80 87.5 73 58.5 73 14.5 4-M4 bolt hole 135 MCCB center line 14.5 Applicable MCCB HBL103U, HBL103UM, HBL203U, HBL203UM Order code Category TFH 20U MCCB HBL103UQ, HBL103UMQ, HBL203UQ, HBL203UMQ MB TFH 20UQ Molded Case Circuit Breaker_ 209 U-Series / Molded Case Circuit Breaker Operating Accessories | Motor operator (MOT) | MOT-12NE Applicable MCCB Model UAB30C, UAB30R, UAB50C, UAB50R, UAB60C, UAB60R, UAB100C / UAD50C UAB50S, UAB50H, UAB100R, UAB100S / UAD50S, UAD100R UCB50R, UCB100R, UCB100S / UCD100S UCB50H, UCB50L, UCB100H, UCB100L / UCD50H, UCD100H UCB250R, UCB250S, UCB250N / UCD250S UCB160H, UCB160L, UCB250H, UCB250L / UCD160H, UCD250H UCB400R, UCB400S, UCB400H, UCB400L / UCD400S UCB630R, UCB630S, UCB630H, UCB630L, UCB800R, UCB800S, UCB800H, UCB800L / UCD630S, UCD800S UCB1000S, UCB1000L, UCB1250S, UCB1250L / UCD1000S, UCD1250S UCB1600S UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X / UPD400S, UPD630S HBL103U, HBL103UM, HBL203U, HBL203UM, HBL103UQ, HBL103UMQ, HBL203UQ, HBL203UMQ Control voltage (V) Operational Operation time (ms) Power Mechanical consumption life (times) current (A) Closing Opening (W) DC24V AC/DC110V AC/DC220V ≤ 2.5 ≤ 0.5 ≤ 0.5 DC24V AC/DC110V AC/DC220V DC24V AC/DC110V AC/DC220V ≤ 2.5 ≤ 0.5 ≤ 0.5 ≤ 5.0 ≤ 3.0 ≤ 2.0 MOT-40D DC24V AC/DC110V AC/DC220V MOT-68E MOT-10A MOT-68E Dimensions (mm) A B C D 310 200 14 25,000 90 132 93 30 310 200 14 10,000 90 132 93 30 350 230 14 8,000 90 126 93 35 ≤ 5.0 ≤ 3.0 ≤ 2.0 350 230 14 5,000 90 144 97 35 DC24V AC/DC110V AC/DC220V ≤ 5.0 ≤ 3.0 ≤ 2.0 500 350 35 5,000 130 215 150 44 MOT-80NE DC24V AC/DC110V AC/DC220V ≤ 5.0 ≤ 3.0 ≤ 2.0 820 500 120 3,000 130 340 150 70 MOT-160NE AC 220V ≤ 2.0 820 500 120 3,000 MOT-12UP DC24V AC/DC110V AC/DC220V ≤ 5.0 ≤ 3.0 ≤ 2.0 700 420 35 10,000 130 130 150 45 DC24V AC/DC110V AC/DC220V DC24V AC/DC110V AC/DC220V ≤ 5.0 ≤ 3.0 ≤ 2.0 ≤ 5.0 ≤ 3.0 ≤ 2.0 700 420 35 5,000 130 243 137 70 700 420 35 10,000 130 130 150 45 MOT-10UA MOT-10B MOT-10F MOT-20C MOT-20G MOT-46UP MOT-12UP MCCB - - - - MCCB A D MCCB C Motor operator 150 142 376 147 Handle B Motor 32 operator 97 Motor operator 210 122 Motor operator [MOT-10/20/40/68/80/12/46] 210 [MOT-160NE] MCCB ■ Control circuit and wiring diagram S3 1 Control power 2 Power K4 K5 3 K4 P1 P2 S1 S2 S4 POWER K4 Ue K3 ON OFF K5 ON 4 K1 K1 ON circuit S1 S2 K3 M : Motor K3 K3 K1 : ON relay K4 K2 : OFF relay K5 Motor control relay K2 OFF ■ OFF circuit 5 K5 S1 : ON limit switch S2 : OFF limit switch S3 : Auto/Manual K2 Standard order code Applicable MCCB Order code DC24V AC/DC110V AC/DC220V UAB30C, UAB30R, UAB50C, UAB50R, UAB60C, UAB60R, UAB100C / UAD50C MOT 10A DC24 MOT 10A ADC110 MOT 10A ADC220 UAB50S, UAB50H, UAB100R, UAB100S / UAD50S, UAD100R MOT 10UA DC24 MOT 10UA ADC110 MOT 10UA ADC220 UCB50R, UCB100R, UCB100S / UCD100S MOT 10B DC24 MOT 10B ADC110 MOT 10B ADC220 UCB50H, UCB50L, UCB100H, UCB100L / UCD50H, UCD100H MOT 10F DC24 MOT 10F ADC110 MOT 10F ADC220 UCB250R, UCB250S, UCB250N / UCD250S MOT 20C DC24 MOT 20C ADC110 MOT 20C ADC220 UCB160H, UCB160L, UCB250H, UCB250L / UCD160H, UCD250H MOT 20G DC24 MOT 20G ADC110 MOT 20G ADC220 UCB400R, UCB400S, UCB400H, UCB400L / UCD400S MOT 40D DC24 MOT 40D ADC110 MOT 40D ADC220 MOT 68E DC24 MOT 68E ADC110 MOT 68E ADC220 MOT 80NE DC24 MOT 80NE ADC110 MOT 80NE ADC220 - - MOT 160NE AC2201) MOT 12UP DC24 MOT 12UP ADC110 MOT 12UP ADC220 MOT 46UP DC24 MOT 46UP ADC110 MOT 46UP ADC220 MOT 12UP DC24 MOT 12UP ADC110 MOT 12UP ADC220 UCB630R, UCB630S, UCB630H, UCB630L, UCB800R, UCB800S, UCB800H, UCB800L / UCD630S, UCD800S UCB1000S, UCB1000L, UCB1250S, UCB1250L / UCD1000S, UCD1250S UCB1600S UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X / UPD400S, UPD630S HBL103U, HBL103UM, HBL203U, HBL203UM, HBL103UQ, HBL103UMQ, HBL203UQ, HBL203UMQ Category MCCB MB ※Motor operator is not recommended for marine application. 1) MOT 160NE AC220 is not applicable for DC220V. Molded Case Circuit Breaker_ 211 U-Series / Molded Case Circuit Breaker Operating Accessories | Mechanical interlock (MIF) | [ Lock in OFF of left side breaker ] Applicable MCCB UAB30C, UAB30R, UAB50C, UAB50R, [ Lock of two breaker ] [ Lock in OFF of right side breaker ] Order code 2 pole 3 pole 4 pole - MIF 10A 3 MIF 10A 4 - MIF 10UA 3 MIF 10AU 4 - MIF 10UF 3 MIF 10UF 4 MIF 10UF 3 MIF 10UF 3 MIF 10UF 4 MIF 20UG 3 MIF 20UG 3 MIF 20UG 4 MIF 40D 3 MIF 40D 3 MIF 40D 4 Category UAB60C, UAB60R, UAB100C / UAD50C UAB50S, UAB50H, UAB100R, UAB100S / UAD50S, UAD100R UCB50R, UCB100R, UCB100S / UCD100S UCB50H, UCB50L, UCB100H, UCB100L / UCD50H, UCD100H UCB160H, UCB160L, UCB250R, UCB250S, UCB250N, UCB250H, UCB250L / UCD160H, UCD250S, UCD250H UCB400R, UCB400S, UCB400H, UCB400L / UCD400S MCCB UCB630R, UCB630S, UCB630H, UCB630L, UCB800R, UCB800S, UCB800H, UCB800L MIF 80E 3 MIF 80E 3 MIF 80E 4 - MIF 12UP 3 MIF 12UP 4 - MIF 46UP 3 MIF 46UP 4 - MIF 12UP 3 MIF 12UP 4 / UCD630S, UCD800S UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X / UPD400S, UPD630S HBL103U, HBL103UM, HBL203U, HBL203UM, HBL103UQ, HBL103UMQ, HBL203UQ, HBL203UMQ 212 MB MCCB | Padlock plate (PLD) | Applicable MCCB Order code Category UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X, UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X / UPD100S, UPD160S, UPD250S, UPD400S, PLD 12UP MCCB MB UPD630S HBL103U, HBL103UM, HBL203U, HBL203UM, HBL103UQ, HBL103UMQ, HBL203UQ, HBL203UMQ | Extension handle (THA) | Applicable MCCB B Order code Dimensions (mm) A B Category UCB400R, UCB400S, UCB400H, UCB400L, UCB630R, UCB630S, UCB630H, UCB630L, UCB800R, UCB800S, UCB800H, UCB800L / THA 46D 42 40 THA 80NE 56 40 THA 160NE 60 50 THA 46UP 42 30 UCD400S, UCD630S, UCD800S UCB1000S, UCB1000L, UCB1250S, UCB1250L / UCD1000S, UCD1250S A Mounting hole UCB1600S MCCB MB UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X / ※ Excessive force in ON and OFF may break the handle of breaker. UPD400S, UPD630S Molded Case Circuit Breaker_ 213 U-Series / Molded Case Circuit Breaker Mounting Accessories � Mounting accessories enable easy installation, maintenances and remove of breakers. DIN-rail adaptor DRA - Mounted on back side of UAB type breaker and enables direct installation on 35mm DIN-rail 214 Mounting base TDM - Installed on back plate of panel and breaker can be easily replaced or maintained without cable disconnection MCCB | Mounting base (TDM) and components for plug-in mounting | �Switchboard application Conductor Mounting base (TDM, TDF) Connection block Circuit conductor Mounting angle Lead cable for signal accessories Connection block (CBM, TYA) ※The shape of mounting bases of each MCCB are not same as above. For exact appearances, please refer to "Characteristic Curves & Dimensions" from page 140-191. For line side only plug-in mounting For both line & load side plug-in mounting Applicable MCCB UAB30C, UAB30R, UAB50C, UAB50R, UAB60C, UAB60R, UAB100C / UAD50C UAB50S, UAB50H, UAB100R, UAB100S / UAD50S, UAD100R UCB50R, UCB50H, UCB50L, UCB100R, UCB100S, UCB100H, UCB100L / UCD100S, UCD50H, UCD100H UCB160H, UCB160L, UCB250R, UCB250S, UCB250N, UCB250H, UCB250L / UCD160H, UCD250S, UCD250H UCB400R, UCB400S, UCB400H, UCB400L / UCD400S UCB630R, UCB630S, UCB630H, UCB630L, UCB800R, UCB800S, UCB800H, UCB800L / UCD630S, UCD800S UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X / UPD400S, UPD630S HBL103U, HBL103UM, HBL203U, HBL203UM, HBL103UQ, HBL103UMQ, HBL203UQ, HBL203UMQ Mounting base Order Required code quantity TDM 10AP TDM 10BP TDM 20CF 1EA TDM 5BA 2EA TDM 12NEP Conn. block barrier Contact Required quantity CBM 10AB 2 2C 1EA CBM 10AB 3 3C 1EA CBM 10AB 2 2C 1EA CBM 10AB 3 3C 1EA CBM 20C 2 2C 1EA CBM 20C 5 5C 1EA TYA 5/22) TYA 5/52) 2C 5C 1EA 1EA TYA 5/22) 2C 1EA 2EA 2EA TDM 46NEP Connection block Order code 1EA TDM 4BA TDM 12NEP 1) TYA 5/52) 5C 1EA CBM 26NE 6 6C 1EA CBM 26NE 12 12C 1EA CBM 26NE 6 6C 1EA CBM 26NE 12 12C 1EA CBM 26NE 6 6C 1EA CBM 26NE 12 12C 1EA 1EA Required quantity Order code Required quantity CBM BARR 1EA TDF 10A 1EA CBM BARR 1EA TDF 10B 1EA - - TDM 20CF 1EA - - TDM 4BA 1EA - - TDM 5BA 1EA - - TDM 12NEF 1EA - TDM 46NEF 1EA TDM 12NEF 1EA Category MCCB 1EA 1EA Mounting base Order code - MB - ※ - Plug-in mounting is applicable for 3P breaker. 1) Connection blocks are required for internal accessory installation in both line & load side plug-in type 3P breaker. 2) TYA type connection blocks are to be installed with separate mounting angle. Separate mounting angle is not supplied. Molded Case Circuit Breaker_ 215 U-Series / Molded Case Circuit Breaker Mounting Accessories �TDF 10A (Unit : mm) [ Mounting base ] [ Connection conductor ] 81 75 25 79 25 130 12.5 59 153.3 3 A 76.5 78.3 A 7 76.5 40.8 7.5 76.5 RH M6 screw+S/W+P/W 15 (Max:18) 9 [ Panel cut-out ] 2 25 25 76.8 9 RH M6 screw+S/W+P/W SEC A-A 5-M4 tapped hole 41 21 36 50 8.5 20 13.5 21.5 3 22 22 �TDF 10B (Unit : mm) [ Mounting base ] [ Connection conductor ] 92 89 172.3 9 2 30 30 97.3 155 3 75 A 7 75 86.3 A 75 39.3 7.5 58.5 15 (Max:18) RH M6 screw+S/W+P/W 12.5 30 30 9 [ Panel cut-out ] SEC A-A 41 36 8.5 20 13.5 21.8 21 5-M4 tapped hole 21.5 3 216 27 27 MCCB �Distribution board application Application Applicable MCCB Order code Required quantity TDA 10AD ASSY TDA 10AS 2RT-PH A 22S-PH10 A BRAN-BARR A CONN-PL A ARC-PL A TDA 10BD ASSY TDA 10BS 2RT-PH 22S-PH10 BRAN-BARR CONN-PL ARC-PL TDA 10AS 1R-PH A 1S-PH 1T-PH 1R-PH10 A 1S-PH10 1T-PH10 TDA 10BS 1R-PH 1S-PH 1T-PH 1R-PH10 1S-PH10 1T-PH10 1EA 2EA 2EA 1EA 2EA 1EA 1EA 1EA 2EA 2EA 1EA 2EA 1EA 1EA 1EA 1EA 1EA 1EA 1EA 1EA 1EA 1EA 1EA 1EA 1EA 1EA 1EA 1EA Item Mounting base unit UAB50R, UAB50S, UAB50H, UAB60R, UAB100C, UAB100R, UAB100S For component order Mounting base Branching conductor Arc protection barrier Connection plate Double mounting Mounting base unit UCB50H, UCB50L, UCB100R, UCB100S, UCB100H, UCB100L For component order Mounting base Branching conductor Arc protection barrier Connection plate Mounting base UAB50R, UAB50S, UAB50H, UAB60R, UAB100C, UAB100R, UAB100S 5-63A Branching conductor 75-125A Single mounting Mounting base UCB50H, UCB50L, UCB100R, UCB100S, UCB100H, UCB100L 5-63A Branching conductor 75-125A Mounting screw M5 x L18 4EA for mounting angle M5 x L12 1EA for bus bar M4 x L8 2EA for brancing conductor M4 x L25 4EA M5 x L20 4EA for mounting angle M5 x L12 1EA for bus bar M4 x L8 2EA for brancing conductor M4 x L25 4EA M4 x L30 4EA for mounting angle M5 x L12 1EA for bus bar M4 x L8 1EA for brancing conductor M5 x L32 4EA for mounting angle M5 x L12 1EA for bus bar M4 x L8 1EA for brancing conductor ※Mounting base shall be connected to load side of MCCB. Branching conductor M5xL12 1S-PH 1S-PH10 M4xL8 M4xL8 M4xL8 M4xL8 M4xL8 M5xL12 M5xL12 M5xL12 M4xL8 M4xL8 M4xL8 2RT-PH 2RT-PH A Connection plate CONN-PL CONN-PL A 22S-PH 22S-PH10 22S-PH A 22S-PH10 A 1R-PH 1R-PH10 1R-PH A 1R-PH10 A 1T-PH 1T-PH10 Arc protection barrier ARC-PL ARC-PL A Molded Case Circuit Breaker_ 217 U-Series / Molded Case Circuit Breaker Mounting Accessories �TDA 10AD / Double mounting Load side terminal 6 50 M5 tapped hole for branching conductor (22S-PH10 A) Connection plate (CONN-PL A) 43.7 18.5 Mounting angle 87 12.5 25 [ Drilling holes for mounting ] M4 nut+S/W+P/W RH screw M4xL18+S/W+P/W M5 tapped hole for branching conductor (2RT-PH A) 25 4- 4.5 hole Line Arc protection barrier (BRAN-BARR A) 28 6 87 50 Line 235 37 RH screw M4xL25+S/W+P/W 43.3 179.5 Connection plate (ARC-PL A) 63 Line 360 235 63 Line hole nting 5 mou 28 M5 tapped hole for branching conductor (2RT-PH A) 15 12.5 50 25 22 80 80 21 �TDA 10AS / Single mounting M5 tapped hole for branching conductor (1T-PH, 1T-PH10) M5 tapped hole for branching conductor (1S-PH, 1S-PH10) 50 M4 nut+S/W+P/W [ Drilling holes for mounting ] 12 Line Mounting angle 33 RH M4xL10+S/W+P/W Line RH screw M4xL30+S/W 24.2 80.8 162 115.3 87 18.5 27.3 9 18.5 M5 tapped hole for branching conductor (1R-PH A, 1R-PH10 A) 46.5 43.7 50 180 162 46.5 9 80.8 Line 43.3 7 7 4- 4.5 hole 50 15 4.5 mounting hole 25 21 80 218 22 80 Insulation plate 1.6t (not supplied) 25 MCCB �TDA 10BD / Double mounting M5 nut+S/W+P/W 27.518.5 RH screw M5xL20+S/W+P/W M5 tapped hole for branching conductor (2RT-PH) M5 tapped hole for branching conductor (22S-PH10) [ Drilling holes for mounting ] Load side terminal 8.5 30 4- 5.5 hole Mounting angle Line 6 50 Connection plate (CONN-PL) Arc protection barrier (BRAN-BARR) 99 27.5 2 50 M4 tapped hole for branching conductor 49.3 2 Line M5 tapped hole for branching conductor (2RT-PH) 248.5 27.5 40 RH screw M4xL25+S/W+P/W 49.7 193.5 Connection plate (ARC-PL) 27.5 65.5 385 248.5 65.5 Line Line Mounting angle 8.5 18.5 5.8 mounting hole 60 15 26 94 24.5 81 20 30 �TDA 10BS / Single mounting M5 tapped hole for branching conductor (1T-PH, 1T-PH10) 50 M5 nut+S/W+P/W 12 RH screw M5xL32+S/W+P/W 16 18.5 10 191 99 18.5 49.7 1.5 46 50 191 M5 tapped hole for branching conductor (1R-PH, 1R-PH10) 27 10 5.8 mounting hole 26 20 24.5 81 172.5 49.3 95.3 8.5 Line 94 86.8 M4 tapped hole Line 46 Line [ Drilling holes for mounting ] 85.7 M5 tapped hole for branching conductor (1T-PH, 1T-PH10) Mounting angle 30 5.5 hole Insulation plate 1.6t (not supplied) Molded Case Circuit Breaker_ 219 U-Series / Molded Case Circuit Breaker Terminal Accessories � Terminal accessories offers convenience of connection, high protection for safety. Terminal bus bar TBB - Increases the distances between terminals Terminal cover TCF - Prevents direct contact to live terminal as well as insertion of external material 220 Cage terminal block CTB - Offers easy and direct connection of cables Interpole barrier TQQ - Increases the insulation between poles MCCB | Terminal connection screws / standard components | Type Clamp screw Pan head screw Hexagon socket head screw Size Applicable MCCB M5 - UAB30C, UAB30R, UAB50C, UAB50R, UAB50S, UAB50H, UAB60C, UAB60R, UAB100C (5-50A), UAB100R (15-50A), UAB100S (15-50A) / UAD50C, UAD50S - UCB50R - UBD30L, UBD30H, UMB30R, UMB30S, UMB30H, UMB50S, UMB50H, UDB30S, UDB30H, UDB50S, UDB50H, UDB100S (15-50A), UDB100H (15-50A), UGD30L, UGD30H, UMG30R, UMG30S, UMG30H, UMG50S, UMG50H, UDG30S,UDG30H, UDG50S, UDG50H, UDG100S (15-50A), UDG100H (15-50A) M8 - UAB100C (60-100A), UAB100R (60-100A), UAB100S (60-100A) / UAD100R - UCB50H, UCB50L, UCB100R, UCB100S, UCB100H, UCB100L, UCB160H, UCB160L, UCB250R, UCB250S, UCB250N, UCB250H, UCB250L / UCD50H, UCD100S, UCD100H, UCD160H, UCD250S, UCD250H - UDB100S (60-100A), UDB100H (60-100A), UDG100S (60-100A), UDG100H (60-100A) M8 - UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S - HBL103U, HBL103UM, HBL203U, HBL203UM, HBL103UQ, HBL103UMQ, HBL203UQ, HBL203UMQ M10 - UCB400R, UCB400S, UCB400H, UCB400L / UCD400S - UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X / UPD400S, UPD630S M12 - UCB630R, UCB630S, UCB630H, UCB630L, UCB800R, UCB800S, UCB800H, UCB800L / UCD630S, UCD800S M12 - UCB1000S, UCB1000L, UCB1250S, UCB1250L / UCD1000S, UCD1250S M13 - UCB1600S Hexagon head screw | Terminal bus bar (TBB) | Order code Applicable MCCB UCB250R, UCB250S, UCB250N / UCD250S UCB160H, UCB160L, UCB250H, UCB250L / UCD160H, UCD250H UCB400R, UCB400S, UCB400H, UCB400L / UCD400S UCB630R, UCB630S, UCB630H,UCB630L / UCD630S UCB800R, UCB800S, UCB800H, UCB800L / UCD800S UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S UPB400S, UPB400H, UPB400L, UPB400X / UPD400S UPB630S, UPB630H, UPB630L, UPB630X / UPD630S HBL103U, HBL103UM, HBL203U, HBL203UM, HBL103UQ, HBL103UMQ, HBL203UQ, HBL203UMQ 2 pole (4EA/SET) 3 pole (6EA/SET) 4 pole (8EA/SET) Mounting Category hole TBB 20C 2 TBB 20C 3 TBB 20C 4 ∮11 TBB 4S 2 TBB 4S 3 TBB 4S 4 ∮13 TBB 6S 2 TBB 6S 3 TBB 6S 4 ∮13 TBB 8S 2 TBB 8S 3 TBB 8S 4 ∮13 [ 2 pole ] MCCB TBB 12NE 3 TBB 12NE 4 ∮11 - TBB 40NE 3 TBB 40NE 4 ∮13 - TBB 60NE 3 TBB 60NE 4 ∮13 - TBB 12NE 3 - ∮11 - [ 3 pole ] MB [ 4 pole ] Molded Case Circuit Breaker_ 221 U-Series / Molded Case Circuit Breaker Terminal Accessories L | Cage terminal block (CTB) | CTB 10A, CTB 10B CTB 20C, CTB 12UP CTB 40D CTB 46UP S CTB 80E Wire Order code Applicable MCCB Connection S (㎟ ) L (㎜ ) Tightening torque (kgf-㎝ ) 3EA/SET 4EA/SET Cable connector (EA) CTB 10A 3S CTB 10A 4S 1 1 X 5.5-50 14 60 CTB 10B 3S CTB 10B 4S 1 1 X 8-50 14 60 CTB 20C 3S CTB 20C 4S 1 1 X 14-120 19 140 CTB 40D 3S CTB 40D 4S 2 2 X 60-120 30-60 353 CTB 80E 3S CTB 80E 4S 3 3 X 85-160 30-60 353 CTB 12UP 3S CTB 12UP 4S 1 1 X 14-120 19 140 CTB 46UP 3S CTB 46UP 4S 2 2 X 60-185 30-60 353 CTB 12UP 3S CTB 12UP 4S 1 1 X 14-120 19 140 Wire size Category UAB30C, UAB30R, UAB50C, UAB50R, UAB60C, UAB60R, UAB100C / UAD50C UAB50S, UAB50H, UAB100R, UAB100S / UAD50S, UAD100R UCB50R, UCB100R, UCB100S / UCD100S UCB50H, UCB50L, UCB100H, UCB100L / UCD50H, UCD100H UCB250R, UCB250S, UCB250N / UCD250S UCB160H, UCB160L, UCB250H, UCB250L / UCD160H, UCD250H UCB400R, UCB400S, UCB400H, UCB400L / UCD400S UCB630R, UCB630S, UCB630H, UCB630L, UCB800R, UCB800S, UCB800H, UCB800L / UCD630S, UCD800S UPB100S, UPB100H, UPB100L, UPB100X / UPD100S UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD160S, UPD250S UPB400S, UPB400H, UPB400L, UPB400X / UPD400S UPB630S, UPB630H, UPB630L, UPB630X / UPD630S HBL103U, HBL103UM, HBL203U, HBL203UM HBL203U, HBL203UM, HBL203UQ, HBL203UMQ 222 MCCB MB MCCB A C B | Terminal cover (TCF) | 3 pole 2 pole Applicable MCCB Dimensions Order code A B TCF 10AP 2 50 59 UCB50R, UCB100R, UCB100S / UCD100S TCF 10BP 2 57 UCB250R, UCB250S, UCB250N / UCD250S TCF 20CP 3 102 90 4 pole Dimensions Category C A B 58.5 TCF 10AP 3 75 59 28.5 58.5 TCF 10BP 3 87 28.5 58.5 TCF 10BP 4 117 28.5 58.5 32.5 58.5 TCF 20CP 3 102 32.5 58.5 TCF 20CP 4 137 32.5 58.5 10 59 TCF 10FP 3 90 10 59 TCF 10FP 4 120 10 59 TCF 20GP 3 105 10 59 TCF 20GP 3 105 10 59 TCF 20GP 4 140 10 59 TCF 40D 3 190 120 100 TCF 40D 3 190 120 100 TCF 40D 4 234 120 100 TCF 80E 3 230 139 100 TCF 80E 3 230 139 100 TCF 80E 4 300 139 100 - - - - TCF 160NE 3 210 51 151 - - - - - - - - TCF 12UP 3 105 29.5 82.5 TCF 12UP 4 140 29.5 82.5 - - - - TCF 46UP 3 140 35 106.5 TCF 46UP 4 185 35 106.5 - - - - TCF 12UP 3 105 29.5 - - - C Order code Dimensions Order code A B C 100 59 58.5 UAB30C, UAB30R, UAB50C, UAB50R, UAB60C, UAB60R, UAB100C / UAD50C UAB50S, UAB50H, UAB100R, UAB100S 58.5 TCF 10AP 4 / UAD50S, UAD100R UCB50H, UCB50L, UCB100H, UCB100L / UCD50H, UCD100H UCB160H, UCB160L, UCB250H, UCB250L / UCD160H, UCD250H UCB400R, UCB400S, UCB400H, UCB400L / UCD400S TCF 10FP 3 UCB630R, UCB630S, UCB630H, UCB630L, UCB800R, UCB800S, UCB800H, UCB800L MCCB MB / UCD630S, UCD800S UCB1600S UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X / UPD400S, UPD630S HBL103U, HBL103UM, HBL203U, HBL203UM, HBL103UQ, HBL103UMQ, 82.5 - HBL203UQ, HBL203UMQ UDB30S, UDB30H, UDB50S, UDB50H, UDB100S, UDB100H, UDG30S, UDG30H, UDG50S, UDG50H, UDG100S, UDG100H ※ For both line and load side of MCCB, 2EA shall be ordered. Molded Case Circuit Breaker_ 223 U-Series / Molded Case Circuit Breaker Terminal Accessories | Interpole barrier (TQQ) | A B B Applicable MCCB Order code Required quantity for both Description (Quantity supplied as line and load side of MCCB standard components 2 pole 3 pole 4 pole of MCCB) Dimensions Category A B UAB30C, UAB30R, UAB50C, UAB50R, UAB60C, UAB60R, UAB100C / UAD50C TQQ 10A 2EA/SET 2 4 6 50 53 UCB50R, UCB100R, UCB100S / UCD100S TQQ 10B 2EA/SET 2 4 6 50 53 UCB250R, UCB250S, UCB250N / UCD250S TQQ 20C 2EA/SET 4 4 6 50 53 TQQ 12FG 2EA/SET 4 4 6 51 53 TQQ 4BA 2EA/SET 4 4 6 120 97 TQQ 5BA 2EA/SET 4 4 6 110 95 TQQ 80NE 4EA/SET - 4 6 125 92 TQQ 160NE 4EA/SET - 4 - 102 68 TQQ 12NE 4EA/SET - 4 6 71 54.5 TQQ 46NE 4EA/SET - 4 6 122 103 TQQ 12NE 4EA/SET - 4 - 71 54.5 TQQ 10A 2EA/SET 2 4 - 50 53 UAB50S, UAB50H, UAB100R, UAB100S / UAD50S, UAD100R UCB50H, UCB50L, UCB100H, UCB100L, UCB160H, UCB160L, UCB250H, UCB250L / UCD50H, UCD100H, UCD160H, UCD250H UCB400R, UCB400S, UCB400H, UCB400L / UCD400S UCB630R, UCB630S, UCB630H, UCB630L, UCB800R, UCB800S, UCB800H, UCB800L / UCD630S, UCD800S UCB1000S, UCB1000L, UCB1250S, UCB1250L / UCD1000S, UCD1250S UCB1600S UPB100S, UPB100H, UPB100L, UPB100X, UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD100S, UPD160S, UPD250S UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X / UPD400S, UPD630S HBL103U, HBL103UM, HBL203U, HBL203UM, HBL103UQ, HBL103UMQ, HBL203UQ, HBL203UMQ UDB30S, UDB30H, UDB50S, UDB50H, UDB100S, UDB100H, UDG30S, UDG30H, UDG50S, UDG50H, UDG100S, UDG100H 224 MCCB MB MCCB Portable Test Equipment | MCCB trip unit tester | �MCCB trip unit tester (MCCB OCR TESTER) can test LTD and STD (below 600%) function of trip unit in the field MCCB OCR TESTER Order code Rated voltage input AC100-230V output DC 9V Dimension W320 x H115 x D265 mm Weight 2.7 kg Standard kit Tester, DC9V adaptor, connector Molded Case Circuit Breaker_ 225 U-Series / Molded Case Circuit Breaker Current Setting for UPB type and UCB 1000-1600 type | UPB100, UPB160, UPB250 / Thermal magnetic type | �Protection characteristics and current setting Rated current [In] (A) LTD ① Rated current setting [Ir] (A) 15 16 20 25 40 50 63 80 100 125 150 160 175 200 225 250 180 200 12 16 24 32 40 50 64 80 100 120 140 160 0.9 14 18 27 36 45 57 72 90 113 135 158 180 203 225 1.0 15 16 20 25 30 32 40 50 63 80 100 125 150 175 200 225 250 Fixed (In x 10) 150 160 200 250 300 320 400 500 630 Trip unit 160 800 1000 1250 1500 1600 1750 2000 2250 2500 + - 20% UPB100: MTM-10-JF, UPB160: MTM-16-JF, UPB250: MTM-25-JF Trip unit Instantaneous 1) current setting Adjustable [Ii] (A) Tolerance ② 32 0.8 In x Tolerance INST 30 - In x 5-6-7-8-9-10 In x 5-9: +30%, -20% In x 10: + - 20% - UPB160: MTM-16-JJ, UPB250: MTM-25-JJ ※ 1) Adjustable instantataneous is available for UPB160 and UPB250. 1 LTD current [Ir] setting knob 2 INST current [Ii] setting knob | UPB100, UPB160, UPB250 / Electronic type | �Protection characteristics and current setting Model UPB100 UPB160 UPB250 MOR-10-ES MOR-16-ES MOR-25-ES 125 160 250 50, 55, 63, 70, 80, 90, 100, 115, 125 63, 70, 80, 90, 100, 110, 125, 140, 160 Trip unit Rated (CT) current [In] (A) LTD STD INST PTA ① Rated current setting [Ir] (A) Long time setting [tr] 6.25 sec. at Ir x 600% 100, 110, 125, 140, 160, 175, 200, 225, 250 + Tolerance - 20% ② Short time pick-up current [Isd] (A) Ir x NON-2-3-4-5-6-7-8-9-10 Tolerance ④ Time delay setting [tsd] 0.05-0.1-0.2-0.3 sec. at definite time-limit section Tolerance In x 1100% Tolerance Ir x 90% Tolerance Instantaneous current setting [Ii] (A) Pre-trip alarm current [Ip] (A) ※The default values are underlined. Please check and adjust the setting condition of each characteristic before use. 1 LTD current [Ir] setting knob 2 STD current [Isd] setting knob 3 Pick-up LED 4 STD time [tsd] setting knob 5 Frequency selection switch 6 Tester connection port 228 +50ms, -20ms + - 20% MCCB | UPB400, UPB630 / Electronic type | �Protection characteristics and current setting Model Trip unit UPB400 UPB630 MOR-40-ES2) / MOR-40-GS MOR-63-ES2) / MOR-63-GS 400 0.8 0.85 0.9 0.95 1.0 Io Ir 0.63 200 215 225 240 250 Rated current setting [Ir] (A) 0.8 255 270 290 300 320 1.0 320 340 360 380 400 2-4-6-8-12 sec. at Ir x 600% Long time setting [tr] Short time pick-up current [Isd] (A) Ir x NON-2-4-6-8-10 0-0.1-0.2-0.3 sec. at definite time-limit section Time delay setting [tsd]1) Instantaneous current setting In x NON-3-6-8-10-11 [Ii] (A) In x NON-0.2-0.3-0.4 Ground fault current [Ig] (A) 0.1-0.2-0.3-0.4-0.8 sec. at definite time-limit section Ground fault delay setting [tg] Ir x 0.9 Pre-trip alarm current [Ip] (A) Rated (CT) current [In] (A) LTD STD INST GFT2) PTA ① ② ③ ④ ⑥ ⑦ ⑧ ⑫ Io Ir 0.63 0.8 1.0 0.8 320 400 500 630 0.85 340 430 540 0.9 0.95 1.0 360 380 400 450 480 500 570 600 630 Tolerance +-20% Tolerance +-15% Tolerance +50ms,-20ms Tolerance +20% - Tolerance Tolerance Tolerance +15% - +50ms, -20ms + 10% - ※- The default values are underlined. Please check and adjust the setting condition of each characteristic before use. 1) I2t characteristic can be ON or OFF by adjusting the [tsd] knob � . 2) GFT protection is option and not applicable for MOR-40-ES and MOR-63-ES trip unit. 1 2 3 4 5 6 LTD current [Ir] setting knob LTD time [tr] setting knob STD current [Isd] setting knob STD time [tsd] setting knob I2t ON-OFF indication INST current [Ii] setting knob GFT current [Ig] setting knob GFT time [tg] setting knob 9 Tester connection port 10 Frequency selection switch 11 Base current [Io] setting knob 12 PTA [Ip] LED 7 8 | UCB1000, UCB1250 / Electronic type | �Protection characteristics and current setting MCCB Trip unit UCB1000 UCB1250 MOR-100-ES2) / MOR-100-GS MOR-125-ES2) / MOR-125-GS 1000 0.8 0.85 0.9 0.95 1.0 Io Ir 0.63 505 535 565 600 630 Rated current setting [Ir] (A) 0.8 640 680 720 760 800 1.0 800 850 900 950 1000 2-4-6-8-12 sec. at Ir x 600% Long time setting [tr] Short time pick-up current [Isd] (A) Ir x NON-2-4-6-8-10 0-0.1-0.2-0.3 sec. at definite time-limit section Time delay setting [tsd]1) Instantaneous current setting In x NON-3-6-8-10-11 [Ii] (A) In x NON-0.2-0.3-0.4 Ground fault current [Ig] (A) 0.1-0.2-0.3-0.4-0.8 sec. at definite time-limit section Ground fault delay setting [tg] Ir x 0.9 Pre-trip alarm current [Ip] (A) Rated (CT) current [In] (A) LTD STD INST GFT2) PTA ① ② ③ ④ ⑥ ⑦ ⑧ ⑫ Io Ir 0.63 0.8 1.0 0.8 630 800 1000 1250 0.85 0.9 0.95 1.0 670 710 750 790 850 900 950 1000 1060 1125 1190 1250 Tolerance +-20% Tolerance +-15% Tolerance +50ms,-20ms Tolerance +20% - Tolerance Tolerance Tolerance +15% - +50ms, -20ms + 10% - ※- The default values are underlined. Please check and adjust the setting condition of each characteristic before use. 1) I2t characteristic can be activate by adjusting [tsd] knob � . 2) GFT protection is option and not applicable for MOR-100-ES and MOR-125-ES trip unit. 1 2 3 4 5 6 LTD current [Ir] setting knob LTD time [tr] setting knob STD current [Isd] setting knob STD time [tsd] setting knob I2t ON-OFF indication INST current [Ii] setting knob GFT current [Ig] setting knob GFT time [tg] setting knob 9 Tester connection port 10 Frequency selection switch 11 Base current [Io] setting knob 12 PTA [Ip] LED 7 8 Molded Case Circuit Breaker_ 229 U-Series / Molded Case Circuit Breaker Current Setting for UPB type and UCB 1000-1600 type | Current setting procedure / Electronic type 400-1250A| In In Io Io Ir Ir Isd Isd 570 Ir Ir 3420 Ii Ii In 5040 In Ig Ig In In In In Io Io Ir Ir 190 1250 1125 Isd Isd Ir 6750 Ir Ii Ii In 10000 In Ig Ig In 375 In | UCB1600 / Electronic type | �Protection characteristics and current setting Rated (CT) current [In] (A) LTD Rated current setting [I1] (A) INST Instantaneous current setting [Ii] (A) LED indication 230 1600 In x 0.4 0.5 0.6 0.7 0.8 0.9 0.95 1.0 640 800 960 1120 1250 1440 1520 1600 I1 x 2-3-4-5-6-7-8-10 Red light I > 0A Green light I > 0.4 x In Yellow light I > I1 MCCB Selection By Application | Model selection for transformer | �AC220V Capacity of Three phase transformer Single phase (kVA) ≤30 ≤50 ≤16 70-100 ≤30 Breaking capacity of MCCB (kA)(Sym) 150-300 ≤50 2.5 5 ≤150 10 UAB30R UAB50C UAB50R UAB60C UAB60R 35 42 50 65 UAB50H, UCB50R UAB100C MCCB ≤2000 ≤300 25 UAB30C ≤1500 500-750 85 UCB50H UAB100S, UCB100R 100 125 UCB50L UCB100S UCB100H UCB100L UPB100H, UPB100L UCB250H UCB250L UPB250H, UPB250L UCB250R UCB250S UCB250N UCB400R UCB400S UCB400H UCB630R UCB630S, UCB630H UPB400S, UPB400H, UPB400L, UPB400X UPB630S, UPB630H, UPB630L, UPB630X UCB800R UCB800S, UCB800H UCB800L UCB400L UCB1000L, UCB1250L UCB1000S, UCB1250S �AC460V Capacity of transformer (kVA) ≤50 Breaking capacity of MCCB (kA)(Sym) ≤300 75-200 1.5 5 ≤750 10 UAB30C UAB30R UAB50C UAB50R UAB60C UAB60R UAB100C 18 25 ≤2000 35 UAB50H, UCB50R 42 UCB50H UAB100S, UCB100R UCB250R MCCB ≤1500 UCB250S UCB400R ≤3000 50 65 75 85 100 UCB50L UCB100S UCB100H UCB100L UPB100H UCB250N UCB250H UCB250L UPB250H UPB250L UCB400L UPB400L, UPB400X UCB400S UCB400H UPB100L UCB630R UCB630S UCB630H UCB630L UPB630L, UPB630X UCB800R UCB800S UCB800H UCB800L UCB1000S, UCB1250S UCB1000L,UCB1250L | Rated current selection for condenser | Rated current of MCCB (A) Capacity of condenser (kVAR) Single phase (1 pole) AC220V Three phase (3 pole) AC440V AC220V AC440V 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 5 60 50 30 30 40 50 30 20 10 75 60 40 40 50 50 30 30 15 100 100 60 50 60 60 40 40 20 175 175 75 60 100 75 50 40 25 200 200 100 100 100 100 50 50 30 225 225 100 100 175 150 60 60 40 400 400 150 125 200 200 100 75 50 400 400 175 175 225 225 100 100 75 600 500 300 300 400 400 150 150 100 800 800 400 400 400 400 225 225 150 1000 1000 600 500 600 600 300 300 200 - 1200 800 800 800 800 400 400 300 - - 1000 1000 - - 600 600 400 - - - - - - - 800 ※-The start-up inrush current is about 10 times of rated current. -The mentioned value can be applied to maximum rated current of MCCB. -The rated current of MCCB is recommended to be 150% of rated current of condenser. Molded Case Circuit Breaker_ 231 U-Series / Molded Case Circuit Breaker Selection By Application | Model selection for lighting and heater | �The maximum operational current shall not exceed 80% of MCCB rated current. Breaking capacity (kA) Maximum operational Rated current sym 2.5 5 current (A) of MCCB (A) 12 15 16 20 24 30 32 40 40 50 48 60 60 75 10 25 UAB30R UAB30C 35 50 65 UAB50H, UCB50H UCB50R UAB50C UAB50R UAB60C UAB60R UAB100S, UCB100R UAB100C 85 100 125 UCB50L UCB100S UCB100H UCB100L UPB100H, UPB100L UCB250H UCB250L UPB250H, UPB250L, 80 100 100 125 120 150 140 175 160 200 180 225 200 250 240 300 280 350 320 400 400 500 500 630 560 700 640 800 800 1000 UCB1000S UCB1000L 1000 1250 UCB1250S UCB1250L UCB250R UCB250S UCB250N UCB400R UCB400S UCB400H UPB400S, UPB400H, UPB400L, UPB400X UCB400L UCB630R UCB630S, UCB630H UPB630S, UPB630H, UPB630L, UPB630X UCB800R UCB800S, UCB800H UCB800L �AC460V Breaking capacity (kA) Maximum operational Rated current sym 1.5 5 current (A) of MCCB (A) 232 10 18 25 35 42 50 65 75 85 100 12 15 16 20 24 30 32 40 40 50 48 60 60 75 80 100 100 125 120 150 140 175 160 200 180 225 200 250 240 300 280 350 320 400 400 500 500 630 560 700 640 800 800 1000 UCB1000S UCB1000L 1000 1250 UCB1250S UCB1250L UAB30R UAB30C UAB50H UCB50H UCB50R UAB50C UAB50R UAB60C UAB60R UAB100C UAB100S UCB100S UCB100H UCB100L UPB100H UPB100L UCB250S UCB250N UCB250H UCB250L UPB250H UPB250L UAB100R UCB250R UCB400R UCB50L UCB400H UCB400L UCB630R UCB630S UCB630H UCB630L UCB800R UCB800S UCB800H UCB800L UCB400S UPB400L, UPB400X UPB630L, UPB630X MCCB | Rated current selection for motor and other loads | Circuit diagram Condition IM1 Permissible current of cable1) [Iw] ΣIM � ΣIL Iw� ΣIM+ΣIL 50A� ΣIM > ΣIL Iw� 1.25ΣIM+ΣIL 50A<ΣIM >ΣIL Iw� 1.1ΣIM+ΣIL IM2 IN IW IL1 IL2 IM : Load current of motor IL : Load current of other loads Rated current of MCCB [In] Less value among IN� 3ΣIM+ΣIL or IN� 2.5Iw. In case of Iw>100A, when calculated value is not matched with the rated current of MCCB, it is recommended to select the right above value. Molded Case Circuit Breaker_ 233 U-Series / Molded Case Circuit Breaker Selection By Application ■ Rated current of MCCB for AC220V three phase induction motor Maximum Total capacity of operational current 0.75 / 1.5 / motors (below kW) (below A) 4.8 8 3 4.5 6.3 8.2 12 15.7 19.5 23.2 30 37.5 45 52.5 63.7 75 86.2 97.5 112.5 125 150 175 220 15 20 30 40 50 75 90 100 125 150 175 100 150 300 350 400 450 500 600 700 800 20 30 40 50 60 100 100 125 150 175 200 225 300 350 400 500 500 600 700 800 900 30 30 40 50 60 100 100 125 150 175 200 225 300 350 400 500 500 600 700 800 900 Capacity of the biggest motor: Capacity of motor (kW) / Full load current (A) 2.2 / 11.1 3.7 / 17.4 5.5 / 26 7.5 / 34 11 / 48 15 / 18.5 / 22 / 65 79 93 30 / 125 37 / 160 45 / 190 5/ 230 75 / 310 90 / 360 110 / 132 / 440 500 30 30 40 50 60 100 100 125 150 175 200 225 300 350 400 500 500 600 700 800 900 50 50 50 60 100 100 125 150 175 200 225 300 350 400 500 500 600 700 800 900 60 75 75 100 100 125 150 175 200 225 300 350 400 500 500 600 700 800 900 100 100 100 100 125 150 175 200 225 300 350 400 500 500 600 700 800 900 125 125 125 150 175 200 225 300 350 400 500 500 600 700 800 900 150 150 150 150 175 200 225 300 350 400 500 500 600 700 800 900 300 300 300 300 350 400 500 500 600 700 800 900 400 400 400 400 400 500 500 600 700 800 900 500 500 500 500 500 500 600 700 800 900 500 500 500 500 500 600 700 800 900 600 600 700 700 700 800 900 700 700 700 800 800 900 1000 1000 1000 900 90 / 180 110 / 132 / 220 250 175 175 175 200 200 225 300 350 400 500 500 600 700 800 900 200 225 225 225 225 300 350 400 500 500 600 700 800 900 1000 1000 1000 ※-The rated currents are for MCCBs. -The mentioned values are applicable when MCCB trips within 10 sec. at 600% of full load current and the start-up inrush current is within 1700% of full load current. -Above selection is also applied in case that several loads starts up at same time. ■ Rated current of MCCB for AC440V three phase induction motor Maximum Total capacity of operational current 0.75 / 1.5 / motors (below kW) (below A) 2.4 4 3 4.5 6.3 8.2 12 15.7 19.5 23.2 30 37.5 45 52.5 63.7 75 86.2 97.5 112.5 125 150 175 200 250 300 350 400 450 500 7.5 10 15 20 25 38 45 50 63 75 88 100 125 150 175 200 225 250 300 350 400 500 600 700 700 900 1000 Capacity of the biggest motor: 2.2 / 5.5 3.7 / 8.7 5.5 / 13 7.5 / 17 11 / 24 Capacity of motor (kW) / Full load current (A) 15 / 18.5 / 22 / 32 39 46 30 / 62 37 / 80 45 / 95 55 / 115 75 / 155 15 15 15 15 15 15 30 20 20 20 30 40 30 30 30 30 40 50 30 30 30 30 40 50 50 50 50 50 50 50 60 75 50 50 50 50 50 50 60 75 100 60 60 60 60 60 60 60 75 100 125 75 75 75 75 75 75 75 100 100 125 100 100 100 100 100 100 100 100 100 125 150 100 100 100 100 100 100 100 100 100 125 150 175 125 125 125 125 125 125 125 125 125 125 150 175 225 150 150 150 150 150 150 150 150 150 150 150 200 225 250 175 175 175 175 175 175 175 175 175 175 175 200 225 250 200 200 200 200 200 200 200 200 200 200 200 200 225 300 350 225 225 225 225 225 225 225 225 225 225 225 225 225 300 350 400 250 250 250 250 250 250 250 250 250 250 250 250 250 300 350 400 300 300 300 300 300 300 300 300 300 300 300 300 300 300 350 400 500 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 400 500 500 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 ※-The rated currents are for MCCBs. -The mentioned values are applicable when MCCB trips within 10 sec. at 600% of full load current and the start-up inrush current is within 1700% of full load current. -Above selection is also applied in case that several loads starts up at same time. 234 MCCB Insulation Distance Insulation plate Upper plate of panel Side plate of panel B1 B1 B1 B2 B2 B2 A D A A Direct cable connection Taping Bus bar connection Applicable MCCB Rear or plug-in connection C Distances A B1 B2 C D 75 50 30 from 0 25 80 50 30 from 0 25 80 60 50 from 0 25 (?) 80 60 50 from 0 40 100 100 80 from 0 80 50 120 80 from 0 80 80 50 30 from 0 10 100 100 70 from 0 10 120 100 80 from 0 80 UAB30C, UAB30R, UAB50C, UAB50R, UAB50S, UAB50H, UAB60C, UAB60R, UAB100C, UAB100R, UAB100S / UAD50C, UAD50S, UAD100R UCB50R, UCB50H, UCB50L, UCB100R, UCB100S, UCB100H, UCB100L / UCD50H, UCD100R, UCD100H UCB250R UCB160H, UCB160L, UCB250S, UCB250N, UCB250H, UCB250L / UCD160H, UCD250S, UCD250H UCB400R, UCB400S, UCB400H, UCB400L, UCB630R, UCB630S, UCB630H, UCB630L, UCB800R, UCB800S, UCB800H, UCB800L / UCD400S, UCD630S, UCD800S UCB1000S, UCB1000L, UCB1250S, UCB1250L, UCB1600S / UCD1000S, UCD1250S UPB100S, UPB100H, UPB100L, UPB100X / UPD100S UPB160S, UPB160H, UPB160L, UPB160X, UPB250S, UPB250H, UPB250L, UPB250X / UPD160S, UPD250S UPB400S, UPB400H, UPB400L, UPB400X, UPB630S, UPB630H, UPB630L, UPB630X / UPD400S, UPD630S HBL103U, HBL103UM, HBL103UQ, HBL103UMQ 80 50 30 from 0 10 HBL203U, HBL203UM, HBL203UQ, HBL203UMQ 100 100 70 from 0 10 Molded Case Circuit Breaker_ 235 U-Series / Molded Case Circuit Breaker Cascading Table | AC240V | Downstream Upstream UAB-C Recognition category UAB-R UAB/UCB-S UAB100C UCB250R UCB400R UCB630R UCB800R UAB100S UCB250S UCB400S UCB630S UCB800S Model Rated current (A) 5-100 125-250 250-400 500,630 700,800 15-100 125-250 250-400 500,630 700,800 Breaking capacity [Icu] (kA r.m.s) 25 35 35 50 50 50 50 50 100 100 UAB30C 3-30 10 25 30 30 35 35 35 UAB50C 5-50 10 25 30 30 35 35 35 UAB60C 5-60 10 25 30 30 35 35 35 UAB100C 5-100 25 35 35 42 42 42 42 65 65 UAB30R 5-30 25 35 35 42 42 42 42 42 65 65 UAB50R 5-50 25 35 35 42 42 42 42 42 65 65 UAB60R 5-60 25 35 35 42 42 42 42 42 65 65 UAB100R 15-100 42 50 50 50 50 75 75 UCB50R 15-50 50 85 85 UCB100R 15-100 50 85 85 UCB250R 125-250 35 65 65 UCB400R 250-400 35 UAB50S 15-50 42 UAB100S 15-100 UAB/UCB-S UCB100S UAB-C UAB/UCB-R 50 50 50 50 50 65 50 50 50 75 75 50 85 85 15-100 65 85 85 UCB250S 125-250 50 85 85 UCB400S 250-400 50 UAB50H 15-50 50 UCB50H 15-50 85 100 100 15-125 85 100 100 UCB250H 125-250 85 100 100 UCB400H 250-400 85 UCB50L 15-50 100 UCB100L 15-125 100 UCB250L 125-250 100 UCB400L 250-400 125 UPB100H 15-125 130 UPB250H 100-250 130 UPB100L 15-125 150 UPB250L 100-250 150 UAB/UCB-H UCB100H UCB-L UPB-H UPB-L 236 50 85 100 MCCB UCB-H UCB-L UPB-H UPB-L UCB100H UCB250H UCB400H UCB630H UCB800H UCB100L UCB250L UCB400L UCB630L UCB800L UPB100H UPB250H UPB100L UPB250L 15-125 125-250 250-400 500,630 700,800 15-125 125-250 250-400 500,630 700,800 15-125 100-250 15-125 100-250 85 85 85 100 100 100 100 125 125 125 130 130 150 150 50 50 50 50 50 65 50 50 50 50 50 65 50 50 50 50 50 65 65 65 65 65 65 85 85 85 65 65 65 65 65 65 65 85 85 85 85 85 100 100 65 65 65 65 65 65 65 85 85 85 85 85 100 100 65 65 65 65 65 65 65 85 85 85 85 85 100 100 75 75 75 75 75 100 100 100 85 85 85 85 100 100 100 100 85 85 85 85 100 100 100 100 65 65 65 100 100 100 85 100 100 100 100 130 130 100 130 130 100 65 100 100 100 100 100 85 100 125 125 125 100 130 85 85 100 125 125 125 100 130 85 85 125 125 125 85 85 75 75 85 85 85 85 85 85 100 100 125 125 125 100 125 125 125 100 125 125 125 100 100 100 100 130 130 125 85 100 100 130 130 130 130 130 130 150 150 130 150 125 100 125 125 125 125 125 125 125 125 125 130 130 150 130 150 150 150 150 150 Molded Case Circuit Breaker_ 237 U-Series / Molded Case Circuit Breaker Cascading Table | AC415V | Downstream Upstream UAB-C Recognition category UAB-R UAB/UCB-S UAB100C UCB250R UCB400R UCB630R UCB800R UAB100S UCB250S UCB400S UCB630S UCB800S Model Rated current (A) 5-100 125-250 250-400 500,630 700,800 15-100 125-250 250-400 500,630 700,800 Breaking capacity [Icu] (kA r.m.s) 10 18 30 45 45 30 25 42 65 65 18 18 30 30 UAB30C 3-30 5 10 7.5 10 10 10 UAB50C 5-50 5 10 7.5 10 10 10 UAB60C 5-60 5 10 7.5 10 10 10 UAB100C 5-100 10 14 14 14 14 UAB30R 5-30 10 14 14 14 14 18 18 18 30 30 UAB50R 5-50 10 14 14 14 14 18 18 18 30 30 UAB60R 5-60 10 14 14 14 14 18 18 18 30 30 UAB100R 15-100 25 30 35 35 35 42 42 UCB50R 15-50 25 30 35 35 35 42 42 UCB100R 15-100 25 30 35 35 35 42 42 UCB250R 125-250 18 30 35 35 30 35 35 UCB400R 250-400 30 UAB50S 15-50 25 UAB100S 15-100 UAB/UCB-S UCB100S UAB-C UAB/UCB-R 30 35 30 35 35 30 35 15-100 36 UCB250S 125-250 25 UCB400S 250-400 42 UAB50H 15-50 30 35 35 UCB50H 15-50 42 45 15-125 42 UCB250H 125-250 42 UCB400H 250-400 65 UCB50L 15-50 UCB100L 30 50 30 35 42 42 35 35 42 42 45 45 42 50 50 35 35 35 42 42 45 65 42 42 42 45 50 50 45 45 50 50 45 45 50 50 50 65 65 15-125 50 65 65 UCB250L 125-250 50 65 65 UCB400L 250-400 100 UPB100H 15-125 100 UPB250H 100-250 100 UPB100L 15-125 130 UPB250L 100-250 130 UAB/UCB-H UCB100H UCB-L UPB-H UPB-L 238 MCCB UCB-H UCB-L UPB-H UPB-L UCB100H UCB250H UCB400H UCB630H UCB800H UCB100L UCB250L UCB400L UCB630L UCB800L UPB100H UPB250H UPB100L UPB250L 15-125 125-250 250-400 500,630 700,800 15-125 125-250 250-400 500,630 700,800 15-125 100-250 15-125 100-250 42 42 65 85 85 50 50 100 100 100 100 100 130 130 14 14 18 25 25 25 14 14 18 25 25 25 14 14 18 25 25 25 18 30 30 30 30 35 35 35 18 18 30 30 30 30 30 35 35 35 35 35 42 42 18 18 30 30 30 30 30 35 35 35 35 35 42 42 18 18 30 30 30 30 30 35 35 35 35 35 42 42 35 42 50 50 35 50 50 50 35 42 50 50 42 50 50 50 35 42 50 50 42 50 50 50 35 42 42 42 42 42 35 42 35 42 50 50 42 45 50 42 50 42 42 42 50 50 50 50 50 42 50 50 50 50 50 65 65 65 50 65 65 65 50 75 75 75 65 65 50 50 50 50 50 50 50 50 50 85 75 42 50 50 50 50 35 50 45 50 50 50 50 65 65 65 50 50 65 65 60 75 75 50 50 85 85 85 85 85 85 85 60 75 75 50 85 85 85 60 75 75 85 85 85 85 85 100 85 65 85 85 100 100 100 65 85 85 100 100 100 65 85 85 100 100 100 100 100 100 100 100 100 130 130 130 Molded Case Circuit Breaker_ 239 MCCB Handling Instruction | Storage | �Do not expose to corrosive gases. �Do not expose to harmful gases including sulfur, ammonia and so on. �Do not expose to high humidity for a long period. �Do not expose to direct sunlight for a long period. �Store at -20℃ to +60℃ without dust and humidity. �Keep the handle in OFF position. | Transportation | �Do not drop or apply shock during transportation. These can cause malfunctions in the breaker. �Hold the breaker body for transportation. Do not hold terminal bus bar or external lead cable of accessories. | Standard operating condition for normal performance | Ambient temperature -5℃ - +40℃, the average temperature for 24 hours shall not exceed 35℃ Relative humidity 45 - 85% Vibration & shock without excessive vibration and shock Altitude Surrounding up to 2,000m without excessive water vapor, oil vapor, smoke, dust, salts and corrosive materials | Installation and connection | �Keep away from direct sunlight. High temperatures can cause malfunctions. �Avoid any vibration or shock. If vibration or shock is expected, install breaker with shock absorber. �Do not cover the terminal part completely for arc exhaust. �Do not take off the black insulation plate in back side of breaker. Otherwise the breaking capacity may be decreased. Otherwise insulation shall be decreased or not secured. �Keep away from dust or metal pieces. When any work that accompanies dust or metal cutting is required, please cover the breaker first. Molded Case Circuit Breaker_ 241 U-Series / Molded Case Circuit Breaker Handling Instruction | Installation and connection | �Tighten the terminal screws to proper torque specified in manual. The loose connection may cause overheating, and excessive torque may damage screws and terminal parts. �Do not apply lubricant on terminal parts. The lubricant lets screws loose and overheating occurs. �Insulate exposed conductors. To prevent short-circuit, be sure to insulate exposed conductors by interpole barrier, terminal cover, insulating tube, insulating tape and so on. ← Insulating supporter �Do not modify the shape of studs or terminal accessories. Excessive force to stud and terminal accessories should also be avoided. �Fix each conductor in parallel. Short-circuit current can occur electromagnetic force between conductors, so each conductor is required to fixed firmly in parallel. [Electromagnetic force per 1m conductor at 3 phase short-circuit] Short -circuit current / Internal power factor (kA) �Reverse feeding of earth leakage circuit breaker is not allowed. In case of reverse feeding, power is supplied to circuit even the breaker trips, and it shall damage trip coil. (Unit : N [kgf]) Distance between conductors 10cm 20cm 10/0.4 490/50 245/25 18/0.3 1863/190 932/95 25/0.2 4412/450 2206/225 35/0.23 8630/880 4315/440 42/0.2 12455/1270 6277/635 50/0.2 17652/1800 8826/900 65/0.2 29910/3050 14955/1525 85/0.2 51190/5220 25595/2510 100/0.2 70804/7220 35402/3610 125/0.2 110815/11300 55408/5650 | Connection of earth leakage circuit breaker | �Single phase three line circuit Power line shall be connected to both side poles of breaker, and neutral line to middle pole. 242 �Single phase two line circuit Circuit shall be connected to both side poles of breaker, and middle pole shall not be connected. �Parallel connection is not allowed. Parallel connection causes current unbalance, malfunction and trip coil damage. MCCB Inspection and Maintenance | Initial inspection | �Please check the following prior to breaker operation. Check point Terminal part shall be clean from dust, metal pieces and so on. Breaker shall not have any crack or damage. There should be non condensation on terminal parts. Insulation resistance should be more than 5MΩ. Terminal screws shall be tightened with specified torque. | Dielectric test | �The test shall be done in these conditions. Main circuit Rated insulation voltage (Ui) Ui � Secondary and control circuit Test voltage AC300V AC300V < Ui � AC600V Rated insulation voltage (Uis) AC2000V Uis � AC2500V AC60V < Uis � Test voltage AC1000V AC60V 2Uis + AC1000V (Max. AC1500V) AC60V �Test for earth leakage circuit breaker Insulation resistance test Dielectric test Handle position Handle position Test Measuring parts Charging parts and earth OFF ON OFF � � � � � � � � Line side × � × � Load side × × × × - � - � R and S phase, S and T phase R and T phase ON Power and line side terminal �Insulation resistance test - Please use AC500V insulation resistance tester. - Do not measure between R and T phase. Measuring does not cause damage unless AC1000V is applied. - The measured resistance value shall be almost 0Ω. �Dielectric test - Do not apply test voltage, if test voltage is applied by mistake, the breaker can not be used. Molded Case Circuit Breaker_ 243 U-Series / Molded Case Circuit Breaker Inspection and Maintenance | Periodic inspection | �In order to maintain the performance of breaker and prevent the unpredicted accident, the inspection shall be accompanied after installation and operation. - Once after one month of operation, thereafter as below. Circumstance Inspection cycle after installation within 10 years : Clean air, no humidity once 2-3 year more than 10 years : once a year more than 15 years : once 6 month Normal within 10 years : Dust but no corrosive gas once a year more than 10 years : once 6 month more than 15 years : once a month Sulfurous gas, salinity, vapor Bad Excessive corrosive gas within 5 years : once 6 year more than 5 years : once a month once a month | Inspection and processing after breaking of fault current | �If there is no pollution in arc exhaust parts and no other abnormality, the breaker can be re-used. �When carbonizing symptom is found around arc exhaust parts, please measure insulation resistance. If the resistance value is more than 5MΩ, no dielectric breakdown at withstand test voltage and no excessive temperature rise of terminal parts, then the breaker can be re-used. �If the handle part is carbonized or there is metallic melting in internal of breaker, please replace it with a new one. 244 MCCB | Troubleshooting | �In case of any abnormality during breaker operation, please handle it as below. �For cases not mentioned in below, please contact us. Molded case circuit breaker Symptom and possible cause Overheating Inferior dielectric Inability of operation �High temperature of terminal part �Damage in insulation part of terminal �Loose connection between terminal and conductor �Tighten screws with specified torque �Heating by resistance increase of conductor �Replace with a new breaker �Heating from connection part between terminal bus bar and breaker �Tighten screws with specified torque �High temperature of breaker body �Heating by resistance increase of conductor �Loose internal assembly screws � Increase of current density from cable disconnection �Replace with a new breaker �Abnormal voltage of load side �Excessive contact abrasion �Foreign substances on contact �Corrosion of conductor by excessive ON-OFF or corrosive gas �Replace with a new breaker �Inability of reset after trip �OFF the breaker after manual reset �Non-energized UVT �Apply the power �Insufficient cooling of trip unit �Reset the breaker after cooling down �Corrosion, damage or deformation of bimetal �Abnormality or damage in mechanism �Exhaustion of durability �Contact melting by excessive high breaking current �Replace with a new breaker �High ambient temperature �Cool down ambient temperature by ventilation or others �Heating by loose terminal screw connection �Tighten screws with specified torque �Heating from inside of breaker �Replace with a new breaker �Smaller connection conductor than specified size �Use the specified size of conductor or adjust the rated current �Inability of ON and RESET �Trip at under rated current Frequent trip �Trip at start-up inrush current �Trip at change-over in star-delta operation �Instantaneous trip at reverse feeding �Trip at operational current Malfunction Troubleshooting �Non trip at the current higher than specified �Instantaneous trip at high start-up inrush current �Instantaneous trip at long start-up inrush current � Adjust the instantaneous trip setting or replace with a higher current breaker �Replace with a higher current breaker �Short-circuit between motors �Repair or replace motors �Misconnection of SHT, UVT control circuit �Inspect circuit wiring �Current breaking by line side fuse or low coordination with primary breaker �Redesign the coordination between equipment �Extremely low ambient temperature �Out of rated frequency �Adjust the current according to temperature derating curve � Apply the rated frequency or adjust breaker frequency knob Molded Case Circuit Breaker_ 245 U-Series / Molded Case Circuit Breaker Inspection and Maintenance Earth leakage circuit breaker Symptom and possible cause �Earth leakage current higher than trip current since Malfunction �Earth leakage test button is projected as soon as the breaker is ON increase of earth interruption capacity depending on wire length �Parallel connection �Mis-connection or disconnection of neutral line Troubleshooting �Adjust the residual current �Install the breaker closer to the load �Inspect the connection and wiring �Excessive surge �Trip during normal operation �Induction noise by high current generating line �Remove or keep away from causes �Noise of electromagnetic waves Accessories Symptom and possible cause �Voltage drop of control circuit �Shunt trip (SHT) Inability of 246 �Replace with a new breaker �Inferior mechanism �Replace with a new breaker �Different rated operational voltage �Apply the rated voltage to UVT malfunction �Auxiliary switch (AUX) and trip alarm switch (ALT) �Adjust voltage to rated level �Coil damage by different voltage and malfunction of coil protection limit switch operation or �Under voltage trip (UVT) Troubleshooting �Damage in contact or contact operation at the current higher than rated current �Inferior mechanism �Repair or replace with a new breaker �Replace with a new breaker