DIRECT OPENING Under the heading “Measures to minimise the risk in the event of failure”, IEC 60204-1 Safety of Machinery-Electrical Equipment Machinery includes the following recommendation: “-the use of switching devices having positive (or direct) opening operation.” 7 TEMBREAK MOULDED CASE CIRCUIT BREAKERS TEMBREAK 2 MOULDED CASE CIRCUIT BREAKERS 16A TO 630A 1. Welcome to TemBreak 2 2. Ratings and Speciļ¬cations 3. Operating Characteristics 4. Application Data 5. Accessories 6. Installation 7. Dimensions TEMBREAK MOULDED CASE CIRCUIT BREAKERS 630A TO 1600A 8. • Easy Selection Guide 131 • Ratings and Specifications 133 • Operating Characteristics 137 • Electrical Control Using Internally Mounted Accessories 139 • Electrical Control Using Motor Operation 143 • Operating Handles 145 • Insulation Accessories 147 • Toggle Accessories 148 • Mechanical Interlocks 149 • Installation 150 • Dimensions 157 SECTION 8 9. TemBreak Moulded Case Circuit Breakers Order Codes page 130 TEMBREAK MOULDED CASE CIRCUIT BREAKERS EASY SELECTION GUIDE The TemBreak range of products includes: -Moulded Case Circuit Breakers -Switch-Disconnectors -A comprehensive range of accessories. EXCEPTIONAL CURRENT LIMITING Terasaki's ingenuity in current breaking is exemplified by the Fast Break Mechanism (FBM) of the TemBreak range. The quick breaking performance of TemBreak provides exceptional current limiting characteristics. F.B.M - Fast Break Mechanism Exceptional Current Limitation Provides kA 84.1 Conventional 800A MCCB SECTION 8 43.4 TemBreak XS800NJ Total break time Quick-break arc chutes Dual repulsive contacts U-shaped conductors Reduced Peak let through minimises electrodynamic stress on conductors Provides Reduced i 2 t energy let through minimises thermal stress on conductors Reduced tripping time minimises damage after fault to both system and MCCB page 131 TEMBREAK MOULDED CASE CIRCUIT BREAKERS EASY SELECTION GUIDE Frame Ratings (A) SECTION 8 Terasaki produce MCCBs up to 2500A. Contact us for details. page 132 TEMBREAK MOULDED CASE CIRCUIT BREAKERS RATINGS AND SPECIFICATIONS TemBreak MCCB Electrical Characteristics to IEC 60947-2, EN 60947-2, JIS C 8201-2-1 Ann. 1, AS/NZS 3947-3, NEMA-AB1 Frame Quantity Unit Condition 800 800 XS800NJ 3, 4 XS800SE 3, 4 630, 800 800 AC 50/60 Hz DC 690 250 690 8 690 690 8 Model Number of Poles Nominal current ratings In (A) Rated operational voltage Ue (V) Rated insulation voltage Rated impulse withstand voltage Ui Uimp (V) (kV) Ultimate breaking capacity (IEC, JIS, AS/NZS) Icu (kA) 690V AC* 525V AC 440V AC 415V AC 380/400V AC 220/240V AC 250V DC 20 35 50 50 65 85 50 20 35 50 50 50 85 - Service breaking capacity (IEC, JIS, AS/NZS) Ics (kA) 690V AC* 525V AC 440V AC 415V AC 380/400V AC 220/240V AC 250V DC 10 18 25 25 33 43 25 10 18 25 25 25 43 - Rated short-time withstand current Rated breaking capacity (NEMA) Icw (kA rms) (kA) 0.3 Seconds 480V AC 240V AC 50 85 10 50 85 A B • • • • • • • • • • 50°C Electrical characteristics Protection SECTION 8 Adjustable thermal, adjustable magnetic Fixed hydraulic, fixed magnetic Microprocessor Utilisation category Installation Front connection (FC) Attached terminal bar (FB) Solderless terminal (cable clamp) Rear connection (RC) Plug-in (PM) Draw-out (DR) DIN rail mounting (DA) Dimensions Weight h w (mm) (mm) d w (mm) (kg) 3 pole 4 pole 3 pole 4 pole 273 210 280 103 9.4 12.2 273 210 280 103 9.7 12.5 • • • • Operation Toggle operation Door mounted (HP) /breaker mounted handle (HB) Motor operation (MC) Standard page 133 • Optional - Not Available *MCCBs cannot be used in IT earthed systems at this voltage. TEMBREAK MOULDED CASE CIRCUIT BREAKERS 800 1600 1250 1250 1600 1600 1600 XH800SE 3, 4 XH800PJ 3, 4 XH800PE 3, 4 TL800NE 3, 4 XS1250CE 3, 4 XS1250SE 3, 4 TL1250NE 3, 4 XS1600CE 3, 4 XS1600SE 3, 4 800 630, 800 630, 800 630, 800 1000, 1250 1000, 1250 1000, 1250 1600 1600 690 690 8 690 250 690 8 690 690 8 690 690 8 690 690 8 690 690 8 690 690 8 690 690 8 690 690 8 20 42 65 65 65 100 - 45 65 85 85 100 125 50 20 42 65 65 65 100 - 45 75 125 125 125 150 - 20 35 50 50 50 85 - 25 45 65 65 85 100 - 45 75 125 125 125 150 - 20 35 50 50 50 85 - 45 65 85 85 100 125 - 10 21 33 33 33 50 - 23 33 43 50 50 63 25 10 21 50 50 50 50 - 34 57 70 70 70 113 - 10 18 25 25 25 43 - 19 34 50 50 65 75 - 34 57 65 65 70/65 113 - 10 18 25 25 25 43 - 34 50 65 65 75 94 - 10 65 85 50 85 10 65 85 15 75 150 15 50 85 15 65 85 15 75 150 20 50 85 20 85 125 B A B B B B B B B - - - - - - • • • • • • • • • • • • • • • - - - - - - • • • • • • • • • • • • • • • • - >1600 Visit www.terasaki.com for details of MCCBs up to 2500A 800 SECTION 8 800 - 273 210 280 103 9.7 12.5 273 210 280 103 9.4 12.2 273 210 280 103 9.7 12.5 370 210 280 140 25.8 33.5 370 210 280 120 22.0 28.0 370 210 280 120 22.0 28.0 370 210 280 140 26.0 33.7 370 210 280 140 27.0 35.0 370 210 280 140 27.0 35.0 • • • • • • • • • • • • • • • • • • page 134 TEMBREAK MOULDED CASE CIRCUIT BREAKERS RATINGS AND SPECIFICATIONS TemBreak Switch-Disconnectors Electrical Characteristics to IEC 60947-3, EN 60947-3, AS/NZS 3947-3 Frame Quantity Unit Condition Model Number of Poles 800 1250 XS800NN 3, 4 XS1250NN 3, 4 800 1250 690 250 690 8 690 250 690 8 15 9.6 AC-23A DC-22A 32 15 AC-23A DC-22A Nominal current ratings Ie (A) Rated operational voltage Ue (V) Rated insulation voltage Rated impulse withstand voltage Ui Uimp (V) (kV) Rated short-circuit making capacity Rated short-time withstand current Utilisation category Icm Icw (kA peak) (kA rms) Electrical characteristics AC 50/60 Hz DC 0.3 Seconds AC DC Installation Front connection (FC) Attached terminal bar (FB) Solderless terminal (cable clamp) Rear connection (RC) Plug-in (PM) Draw-out (DR) DIN rail mounting (DA) Dimensions Weight - • • • • • h w (mm) (mm) d w (mm) (kg) 3 pole 4 pole 3 pole 4 pole - • • • 273 210 280 103 9.4 12.2 370 210 280 120 20.4 26.4 • • • • Operation SECTION 8 Toggle operation Door mounted (HP) / breaker mounted handle (HB) Motor operation (MC) page 135 Standard • Optional - Not Available TEMBREAK MOULDED CASE CIRCUIT BREAKERS 1600 XS1600NN 3, 4 1600 690 250 690 8 45 20 AC-23A DC-22A - • - • 370 210 280 140 24.9 32.9 • • SECTION 8 page 136 TEMBREAK MOULDED CASE CIRCUIT BREAKERS OPERATING CHARACTERISTICS SECTION 8 800A Frame MCCBs page 137 TEMBREAK MOULDED CASE CIRCUIT BREAKERS OPERATING CHARACTERISTICS 1250A and 1600A Frame MCCBs SECTION 8 page 138 TEMBREAK MOULDED CASE CIRCUIT BREAKERS ELECTRICAL CONTROL USING INTERNALLY MOUNTED ACCESSORIES Shunt Trip (SHT) Auxiliary Switch (AX) Remote tripping of the breaker Electrically indicates On/Off status of the breaker. Undervoltage Trip (UVT) Alarm Switch Automatically trips the breaker when the circuit voltage falls below pre-set value. Remote tripping of the breaker is also possible. Note: The UVT controller is installed externally, when provided with AC UVT. (Refer to Dimensions) Note: The SHT and UVT cannot be mounted in the same breaker. SECTION 8 Overview of Internally Mounted Accessories page 139 (AL) Electrically indicates when the breaker is in the "Tripped" state. TEMBREAK MOULDED CASE CIRCUIT BREAKERS ELECTRICAL CONTROL USING INTERNALLY MOUNTED ACCESSORIES Valid Combinations of Internally Mounted Accessories Accessory Combinations Accessory Combinations for Plug-in MCCBs SECTION 8 The arrangements shown above represent the view on the arrow, that is, looking at the MCCB body from the rear. page 140 TEMBREAK MOULDED CASE CIRCUIT BREAKERS ELECTRICAL CONTROL USING INTERNALLY MOUNTED ACCESSORIES SECTION 8 Connection Diagrams and Terminal Numbers Ratings of Auxiliary Switches (AX) and Alarm Switches (AL) page 141 TEMBREAK MOULDED CASE CIRCUIT BREAKERS ELECTRICAL CONTROL USING INTERNALLY MOUNTED ACCESSORIES Operation of Auxiliary and Alarm Switches Ratings of Shunt Trips Ratings of Under Voltage Trips If the UVT is for AC use, an external controller will be installed. The controller is fitted to the left side of the breaker as standard. The controller may be installed separately if required (please specify location). Separate installation is necessary when mechanical interlocks are fitted. UVT controllers incorporating time delay units are also available (contact us for details). Refer to dimensions of terminal blocks for the mounting positions of UVT controllers. SECTION 8 Connection of UVT Controller Termination of Control Wiring Leads for internally mounted accessories can be connected to the terminal block. Each terminal block has six terminals. Terminal arrangements are standardised. Refer to dimensions for standard terminal arrangements. page 142 TEMBREAK MOULDED CASE CIRCUIT BREAKERS SECTION 8 ELECTRICAL CONTROL USING MOTORISED OPERATION page 143 TEMBREAK MOULDED CASE CIRCUIT BREAKERS ELECTRICAL CONTROL USING MOTORISED OPERATION SECTION 8 page 144 TEMBREAK MOULDED CASE CIRCUIT BREAKERS OPERATING HANDLES Door Mounted Handle ER Handle unit C RO Optional key lock Door Mounted Handle with Optional Keylock The door mounted handle is used to operate a circuit breaker mounted inside a cubicle from outside the door. It consists of an operating mechanism that Operating is mounted on the breaker, unit an operating handle that is mounted on the door, and a shaft Anti-tamper that transmits the turning force sleeved from the handle to the operating extensions unit. The shaft can be cut to the required length. The appearance and operation of this handle match those of the door mounted handle for Tembreak 2 MCCBs (details in Section 5). SECTION 8 This means that a switchboard containing a combination of TemBreak and TemBreak 2 MCCBs from this catalogue can be operated with external operating handles which all look the same, and work the same way. page 145 TEMBREAK MOULDED CASE CIRCUIT BREAKERS OPERATING HANDLES Breaker Mounted Handle SECTION 8 page 146 TEMBREAK MOULDED CASE CIRCUIT BREAKERS INSULATION ACCESSORIES Terminal Covers Terminal covers prevent exposure of terminals and other live parts. Terminal Covers for Front Connection. Terminal Covers for Rear Connection and Plug-in. Interpole Barriers SECTION 8 Interpole barriers provide maximum insulation between phases at the terminals of the MCCB. They can not be fitted at the same time as any of the terminal covers. Interpole barriers can easily be fitted to either end of an MCCB. Interpole Barriers page 147 TEMBREAK MOULDED CASE CIRCUIT BREAKERS TOGGLE ACCESSORIES Toggle Extension The toggle extension provides extra leverage for the operator when performing manual ON, OFF and RESET operations. Toggle Extension Toggle Lock The toggle lock enables padlocking of the MCCB in either the ON or OFF position. Padlocks are not supplied. SECTION 8 Note: Fits up to three padlocks Toggle Lock Key Lock MCCBs , including those fitted with door mounted handles and some motor operators can be supplied with Castell locking systems. Contact us for details. Door Flange A door flange provides a neat finish for the toggle cutout on the outside of the panel door. page 148 TEMBREAK MOULDED CASE CIRCUIT BREAKERS MECHANICAL INTERLOCKS Rear Interlocks Rear interlocks consist of a mechanism mounted at the back of each MCCB of an adjacently mounted pair. The interlock inhibits the closure of one MCCB if the other is already in the ON position. MCCBs cannot be mounted directly to a flat plate, but are installed on a frame to ensure space for the interlock mechanism. Two MCCBs or switch-disconnectors of the same frame size may be rear interlocked. An operating handle or motor operator can be fitted to an MCCB with rear interlock. Wire Interlock Wire interlocks consist of two mechanisms connected by a cable. The mechanisms are mounted on the back of two MCCBs located at a distance from each other which is limited by the length and bend radius of the cable. The mechanisms inhibit the closure of one MCCB if the other is already in the ON position. MCCBs cannot be mounted directly to a flat plate, but are installed on a frame to ensure space for the interlock mechanism. Any two of the TemBreak MCCBs or switch disconnectors featured in this catalogue may be wire interlocked. An operating handle or motor operator can be fitted to an MCCB with rear interlock. TemTransfer Automatic Changeover Controller SECTION 8 TemBreak MCCBs can be configured to provide automatic supply changeover. They are compatible with the TemTransfer changeover controller. Refer to section 5 for details. Front Mechanical Interlock Front interlocks are manually operated toggle locking devices which can be installed between two adjacent MCCBs. Depending on the position of the interlock, one or other of the MCCBs is inhibited from being in the ON position. Two MCCBs or switch-disconnectors of the same frame size may be front interlocked. Operating handles and motor operators cannot be fitted to MCCBs with front mechanical interlocks. page 149 TEMBREAK MOULDED CASE CIRCUIT BREAKERS INSTALLATION Connection of Busbars and Terminated Cables This method is standard for 800A frame models. Solid conductors or cables terminated with compression terminals can be used. Connection of Large Conductors and Multiple Conductors Terminal bars are terminal extensions which can be fitted to line or load side terminals and are used to connect large conductors and multiple conductors. Optional for 800A frame, standard for 1250A and 1600A frame models. SECTION 8 page 150 TEMBREAK MOULDED CASE CIRCUIT BREAKERS INSTALLATION Termination in a Separate Compartment Rear connections allow termination of conductors in a different switchboard compartment to the MCCB body. Optional. SECTION 8 Rear Connections for 800A Frame MCCBs Rear Connections for 1250A and 1600A frame MCCBs page 151 TEMBREAK MOULDED CASE CIRCUIT BREAKERS Plug-in Mounting The plug-in mounting system allows fast replacement of the MCCB body without the need to disturb the terminations. Solid conductors or cables terminated with compression terminals can be used. Plug-in mounting is available for 800A and 1250A frame MCCBs. SECTION 8 page 152 TEMBREAK MOULDED CASE CIRCUIT BREAKERS Drawout Mounting SECTION 8 Two types of drawout mounting system are used, depending on the frame size of the MCCB. page 153 TEMBREAK MOULDED CASE CIRCUIT BREAKERS Insulation Distances Attention 80 SECTION 8 page 154 TEMBREAK MOULDED CASE CIRCUIT BREAKERS Standard Installation Environments and Special Treatments SECTION 8 Fungus Moisture Proof Breaker page 155 TEMBREAK MOULDED CASE CIRCUIT BREAKERS Power Consumption SECTION 8 page 156 TEMBREAK MOULDED CASE CIRCUIT BREAKERS DIMENSIONS SECTION 8 XS800NN, XS800NJ, XS800SE, XH800SE, XH800PJ, XH800PE page 157 TEMBREAK MOULDED CASE CIRCUIT BREAKERS DIMENSIONS XS1250NN, XS1250CE, XS1250SE SECTION 8 page 158 TEMBREAK MOULDED CASE CIRCUIT BREAKERS DIMENSIONS SECTION 8 XS1600NN, XS1600CE, XS1600SE page 159 TEMBREAK MOULDED CASE CIRCUIT BREAKERS DIMENSIONS TL-800NE, TL-1250NE ASL: Arrangement Standard Line HL : Handle Frame Centre Line Front connected Drilling plan 184 ASL ASL 28 18 154 170 140 370 ASL 88 8 140 210 ø9 70 A 70 70 70 105 175 280 45 4P 3P HL 68 Extension handle (removable) 170 13 200 13 A 31 Conductor overlap, max. 33 32 15 8 4P HL 88 Mounting 3P hole HL ø13 17 80 46 140 M8 Mounting screw 191 Breaker type A B TL-800NE 10 10 TL-1250NE 14 12 Rear connected with motor operator Drilling plan 4P Panel cutout 4P 3P 3P Insulator 40 70 230 115 296 70 70 ASL 98 113 45 ø13 70 Conductor Soft plastic tubing, overlap, max. ø50, to be provided on center pole and neutral pole of vertical terminal type for insulation. 262.5 226 75 11(max.) 4.5 Mounting plate 19 ASL 111 15 32 8 B 140 73 71 27 86 154 184 13 114 70 ASL ø9 262.5 HL M8 Mounting screw 3P HL 6 18 4P HL R HL ø9 70 81 • Panel cutout dimensions shown give an allowance of 1.5 mm around the handle escutcheon. 300 ø15 for accessory wiring when necessary Note: In the standard shipment mode, both terminals on the line side and the load side are in horizontal direction. For the vertical arrangement, specify it when ordering. SECTION 8 Plug-in Mounting block (XDM8) 3P HL Mtg. Angle 3P HL 4P HL 90 90 Drilling plan 4P Mtg. Angle 3P 26 4P M10 Mounting screw Accessory connection block HL 70 Conductor overlap, max. ø13 140 210 70 70 70 175 105 280 94 94 21 199 70 64 64 25 58 147 8 32 85 15 45 70 62 85 ASL 21 169 ASL 26 18 144 13 114 ASL 21 25 58 15 158 18 ø11 90 page 160 TEMBREAK MOULDED CASE CIRCUIT BREAKERS DIMENSIONS UVT Controller/ OCR Controller A SECTION 8 Door Mounted Handle page 161 B C OCR controller 57.5 45 59 UVT controller 81.5 69 83 TEMBREAK MOULDED CASE CIRCUIT BREAKERS DIMENSIONS Breaker Mounted Handle Toggle Extension SECTION 8 page 162 TEMBREAK MOULDED CASE CIRCUIT BREAKERS DIMENSIONS Terminal Covers for Front-Connections Terminal Covers for Rear Connections and Plug-in Connections SECTION 8 Interpole Barriers page 163 TEMBREAK MOULDED CASE CIRCUIT BREAKERS DIMENSIONS Front Interlock Rear Interlock SECTION 8 page 164 TEMBREAK MOULDED CASE CIRCUIT BREAKERS DIMENSIONS Wire Interlock SECTION 8 Terminal Blocks page 165 TEMBREAK MOULDED CASE CIRCUIT BREAKERS DIMENSIONS Door Flange Panel Cutout for Adjustment Dials SECTION 8 page 166 TEMBREAK MOULDED CASE CIRCUIT BREAKERS DIMENSIONS Toggle Operation and Dimensions SECTION 8 Position of Trip Button and Externally Mounted Accessories page 167