power distribution Double Break Rotary Isolator Type tested design Manual or motor operated System voltage 33kV/66kV Australian design and manufacture Rated short time withstand current 31.5kA (3 seconds) Double Break Ro General arrangement The Ampcontrol double break rotary isolator has been type tested by a NATA approved testing authority and complies with Australian Standard AS 1306 - 1985 and IEC 60129 amendments parts I and II. Options exist to supply the unit partially assembled or in a basic flat pack assembly. Basic unit The basic triple pole rotary isolator can be supplied with two 2900mm high galvanised steel support columns and is padlockable in the on and off positions. All isolators are supplied with a manual operating handle and linkages. Operating shaft lengths can be customised to suit individual requirements. Mounting options include utilising the support columns, pole mount or assembly onto a switchroom roof. Features/Benefits: • • • • • • • • • • Australian design and manufacture to suit local conditions Engineering support readily available - application assistance Low maintenance - cost effective Type tested design complies to Australian and IEC Standards - reliability assured Positive 2:1 switch movement provides ease of operation Motor operated open/closing mechanism option available (type tested) Part assembled option simplifies installation Load and/or line side earth switch option available Integrated mechanical interlocking ensures failsafe operation Security key option enhances operator safety Applications: • • • • • • Feeder isolators Switchyards Zone substations Traction installations Relocatable substations Mobile mining substations POWER THROUG otary Isolator Simplified installation The isolator is available in both flat pack and part assembled formats ready for installation. The part assembled option can reduce the amount of time required on-site and simplifies the switchgear installation. The ground level erection process requires only four stages - stand the two support columns, position the base frame on the columns, mount operating handles and fit interconnecting rods. Final inspection and operational checks follow. Earth switches Earth switches can be fitted for load and/or line side operation and are provided with a mechanical interlock to prevent simultaneous closing onto the isolator. All standard earth switches are supplied with a manual operating handle and linkages. Earth switch auxiliary contacts are also available. Flicker blades Stainless steel flicker blades can be supplied for installations requiring the breaking of low currents associated with system stored energy, such as line charging currents in cables or overhead lines. Rotary isolator auxiliary contacts To allow status signalling for manually operated isolators a separate position indicating switch can be provided in an IP66 metal enclosure. Motor operator As an alternative to manual operation, a type tested design DC motor drive assembly can be fitted to the isolator in lieu of the operating handle. The motor control assembly is fully self contained and supplied in an IP66 metal enclosure. Solenoid interlock The operating handle can be fitted with an electrical solenoid interlock arrangement complete with auxiliary contacts. A mechanical key style interlock kit can also be implemented GH INNOVATION Isolator and earth switch utilise multi-contact parallel arrangement Manual operating handle Earth switch operating mechanism Technical Ratings Description System highest primary voltage 36kV rms 72.5kV rms System nomial primary voltage 33kV 66kV Rated short-time withstand current for 3 seconds 31.5kA rms 31.5kA rms Phases per unit 3 3 Impulse - flashover co-ordinated 200kVp 325kVp Rated frequency 50Hz 50Hz Rated normal current 1250-2000A rms 1250-2000A rms Rated peak withstand current 78.8kA 78.8kA Class Outdoor Outdoor Lightning impulse, full wave, either polarity -- Phase to earth and between poles -- Across open disconnector 200kVp 230kVp 325kVp 375kVp Power frequency (1 minute) -- Phase to earth (dry) -- Across open disconnector (dry) -- Phase to earth (wet) -- Across open disconnector (wet) 70kV 80kV 60kV 80kV 140kV 160kV 140kV 160kV Accessories • • • • • • • • ROT-02/09 Value Galvanised support columns Security key interlock adaptor kit Earth switch auxiliary contacts Earth switch position indication flags Flicker blades Rotary isolator auxiliary contacts Motor operator 110VDC Solenoid interlock kits AMPCONTROL POWER Ampcontrol SWG ABN 78 001 737 533 6 Martin Drive Tomago NSW 2322 Phone:(02) 4964 8288 Fax: (02) 4964 8555 power@ampcontrolgroup.com www.ampcontrolgroup.com rms rms rms rms rms rms rms rms Test report No. 101187 IEC 60129: 1984 with amendments No's 1 and 2 (Mechanical endurance: motor operator/disconnector/earth switch - 1000 operations). AS1306 - 1985High voltage AC switchgear and control gear - disconnectors (isolators) and earthing switches (Mechanical endurance: motor operator/disconnector/earth switch 1000 operations). AS2395 - 1980Terminals for switchgear assemblies for alternating voltages above 1kV. AS2650 - 1986High voltage AC switchgear and control gear - common requirements.