Tunable Notch Filters MINI-POLE® NOTCH SERIES Specifications: Frequency Coverage (7 Bands): 1.5 to 400 MHz Input/Output Impedance: 50Ω Passband VSWR: 2:1 max. Stopband RF Power Handling: 0.5 Watt (input) Passband RF Power Handling: (offset dependent) > 10 Watts @ ± 10% offset typical Passband Third Order Intercept: +50 dBm (input, fo > 30 MHz) Passband Insertion Loss: 1 dB max. Tuning Control: 8 bit parallel Tuning Speed: 10 µS (fo > 30 MHz, +10 dBm reference) DC Power: +5 VDC @ 10 to 250 mA +100 VDC @ 1 mA Center Frequency Drift: 80 PPM/°C Operating Temperature Range: Size: -40° to +85°C 0.6 × 1.4 × 2.3 (in.) / 15.2 × 35.6 × 58.4 (mm.) Weight: 3.2 oz. / 90.7 g. MINI-POLE® NOTCH Filters are optimized for small physical size and low power consumption. Two standard package styles are available (PC-Mount and SMA). For interface and mechanical outline, please refer to the bandpass MINI-POLE® section on pages 14-19. MINI-POLE® NOTCH Filters Product Number Selection Guide: Series Frequency (MHz) Notch Depth (dB) Options MINI-NOTCH 4-10 20 B MINI PC-NOTCH 10-30 C 90-200 Available Options:B. Serial Interface C. Custom Frequency Bands (Specify START and STOP frequencies in MHz.) Note(s):1. Options may be limited to particular frequency bands and/or configurations. Consult factory for your application. 2. Filters are aligned and tested using a High Bias of +100 VDC unless otherwise specified by the customer. Deutschland Telemeter Electronic GmbH Tel. +49 9 06 7 06 93-0 Fax +49 9 06 7 06 93-50 info@telemeter.de www.telemeter.info Schweiz Telemeter Electronic GmbH Tel. +41 71 6 99 20 20 Fax +41 71 6 99 20 24 info@telemeter.ch www.telemeter.info Tschechische Republik Telemeter Electronic s.r.o. Tel. +420 3 85 31 06 37 Fax +420 3 85 51 01 24 info@telemeter.cz www.telemeter.info Performance: The following plots illustrate approximate performance (not representative of all frequency ranges) MINI 90-200, 20 dB NOTCH (@ 150 MHz) Insertion Loss (dB) Insertion Loss (dB) MINI 90-200, 20 dB NOTCH (@ 90 MHz) Frequency (MHz) MINI 90-200, 20 dB NOTCH (@ 200 MHz) MINI 90-200, 20 dB NOTCH (Broadband) Insertion Loss (dB) Insertion Loss (dB) Frequency (MHz) Frequency (MHz) Frequency (MHz) Deutschland Telemeter Electronic GmbH Tel. +49 9 06 7 06 93-0 Fax +49 9 06 7 06 93-50 info@telemeter.de www.telemeter.info Schweiz Telemeter Electronic GmbH Tel. +41 71 6 99 20 20 Fax +41 71 6 99 20 24 info@telemeter.ch www.telemeter.info Tschechische Republik Telemeter Electronic s.r.o. Tel. +420 3 85 31 06 37 Fax +420 3 85 51 01 24 info@telemeter.cz www.telemeter.info Data is believed to be accurate. All data is subject to change without notice. Tunable Notch Filters Information/Quote Requests: Tunable Notch Filters MAXI-POLE® NOTCH SERIES Specifications: Frequency Coverage (7 Bands): 1.5 to 400 MHz Input/Output Impedance: 50Ω Passband VSWR: 2:1 max. Stopband RF Power Handling: 0.5 Watt (input) Passband RF Power Handling: (offset dependent) > 10 Watts @ ± 10% offset typical Passband Insertion Loss: 1 dB max. Passband IP3: +50 dBm (input, fo > 30 MHz) Tuning Control: 8 bit parallel Tuning Speed: 10 µS (fo > 30 MHz, +10 dBm reference) DC Power: +5 VDC @ 10 to 500 mA +100 VDC @ 1 mA Center Frequency Drift: 80 PPM/°C Operating Temperature Range: Size: MAXI-POLE® NOTCH Filters offer all of the same performance features as the Mini-Notch filters, with the advantage of an improved notch shape factor. For interface and mechanical outline, please refer to the bandpass MAXI-POLE® section on pages 20-23. -40° to +85°C 1.5 × 2.5 × 3.3 (in.) / 38.1 × 63.5 × 83.8 (mm.) Weight: 9.2 oz. / 260.8 g. MAXI-POLE® NOTCH Filters Product Number Selection Guide: Series Frequency (MHz) Notch Depth (dB) MAXI-NOTCH 1.5-4 20 Options A 4-10 B 10-30 C 30-90 F 90-200 200-400 225-400 Available Options:A. Internal DC-DC converter (eliminates need for high voltage supply. Requires additional 250 mA of 5 VDC current.) B. Serial Interface C. Custom Frequency Bands (Specify START and STOP frequencies in MHz.) F. Filtered D-connector Note(s):1. Options may be limited to particular frequency bands and/or configurations. Consult factory for your application. 2. Filters are aligned and tested using a High Bias of +100 VDC unless otherwise specified by the customer. Deutschland Telemeter Electronic GmbH Tel. +49 9 06 7 06 93-0 Fax +49 9 06 7 06 93-50 info@telemeter.de www.telemeter.info Schweiz Telemeter Electronic GmbH Tel. +41 71 6 99 20 20 Fax +41 71 6 99 20 24 info@telemeter.ch www.telemeter.info Tschechische Republik Telemeter Electronic s.r.o. Tel. +420 3 85 31 06 37 Fax +420 3 85 51 01 24 info@telemeter.cz www.telemeter.info Performance: The following plots illustrate approximate performance (not representative of all frequency ranges) MAXI 90-200, 20 dB NOTCH (@ 150 MHz) Insertion Loss (dB) Insertion Loss (dB) MAXI 90-200, 20 dB NOTCH (@ 90 MHz) Frequency (MHz) MAXI 90-200, 20 dB NOTCH (@ 200 MHz) MAXI 90-200, 20 dB NOTCH (@ Broadband) Insertion Loss (dB) Insertion Loss (dB) Frequency (MHz) Frequency (MHz) Frequency (MHz) Deutschland Telemeter Electronic GmbH Tel. +49 9 06 7 06 93-0 Fax +49 9 06 7 06 93-50 info@telemeter.de www.telemeter.info Schweiz Telemeter Electronic GmbH Tel. +41 71 6 99 20 20 Fax +41 71 6 99 20 24 info@telemeter.ch www.telemeter.info Tschechische Republik Telemeter Electronic s.r.o. Tel. +420 3 85 31 06 37 Fax +420 3 85 51 01 24 info@telemeter.cz www.telemeter.info Data is believed to be accurate. All data is subject to change without notice. Tunable Notch Filters Information/Quote Requests: Tunable Notch Filters MAXI/4R NOTCH SERIES Specifications: Frequency Coverage: Input/Output Impedance: Passband VSWR: 50Ω 2:1 max. Passband RF Power Handling: Notch Depth: (offset dependent) > 50 Watts @ FN ± 20 MHz typical 35 dB min. Notch Width: FN ± 300 KHz min. 3 dB Bandwidth: 10 MHz typical RF Power Handling at FN: Passband: ≥1 Watt input 100 to 500 MHz Passband Insertion Loss: Passand IP3: 1 dB max. +50 dBm (10/20 MHz) Tuning Control: 9 bit serial Tuning Speed: 40 µS (1 MHz clock) DC Power: The MAXI/4R NOTCH contains 4 “poles” of filtering to provide additional rejection at the tuned frequency of the notch when compared to our standard MAXI-POLE® Notches. The unit has been designed for applications in UHF receiver front ends (nearby transmitter carrier rejection) and/or transmitter back ends (broadband noise rejection at the frequency of a nearby receiver). +5 VDC @ 1.5 A max. +100 VDC @ 2 mA Operating Temperature Range: Center Frequency Drift: Size: 225 to 400 MHz* -40° to +70°C (internal temp. comp.) 3.1 × 3.5 × 7.0 (in.) / 79.4 × 88.9 × 177.8 (mm.) Weight: 56 oz. / 1588 g. / 1.6 kg. * Consult factory for additional ranges. Mechanical Outline: Deutschland Telemeter Electronic GmbH Tel. +49 9 06 7 06 93-0 Fax +49 9 06 7 06 93-50 info@telemeter.de www.telemeter.info Schweiz Telemeter Electronic GmbH Tel. +41 71 6 99 20 20 Fax +41 71 6 99 20 24 info@telemeter.ch www.telemeter.info Tschechische Republik Telemeter Electronic s.r.o. Tel. +420 3 85 31 06 37 Fax +420 3 85 51 01 24 info@telemeter.cz www.telemeter.info Tunable Notch Filters Information/Quote Requests: Performance: Fn=300 MHz 0 0 -6 -6 -12 -12 Insertion Loss (dB) Insertion Loss (dB) Fn=225 MHz -18 -24 -30 -36 -42 -48 -18 -24 -30 -36 -42 -48 -54 -54 -60 205210 215 220225 230235 240 245 -60 280285 290 295300305310 315 320 Frequency (MHz) Frequency (MHz) Wide Band Performance 0 -6 -6 -12 -12 Insertion Loss (dB) Insertion Loss (dB) Fn=400 MHz 0 -18 -24 -30 -36 -42 -18 -24 -30 -36 -42 -48 -48 -54 -54 -60 -60 50 100150 200250300 350400 450500 550 380385 390 395400 405410 415 420 Frequency (MHz) Frequency (MHz) Pinout & Ratings: Power and control 15 pin “D” connector PINOUT: Data is believed to be accurate. All data is subject to change without notice. PIN # Reference Designator Description 1 DO Serial Data Out 2 – N/C 3 – N/C 4 – N/C 5 – N/C 6 – N/C 7 GND Ground 8 +5V +5 VDC @ 1.5 A max. 9 GND Ground 10 +100V +100 VDC @ 2 mA max. 11 GND Ground 12 GND Ground 13 STB Strobe 14 SER CLK Serial Clock 15 DI Serial Data In Note: N/C = No Connect. Tunable Notch Filters POWER-POLE® NOTCH SERIES Specifications: Frequency Coverage (3 bands): 30 to 90 MHz Input/Output Impedance: 50Ω Passband VSWR: 2:1 max. Stopband RF Power Handling: 4 Watts input Passband RF Power Handling: (offset dependent) > 50 Watts @ ± 10% offset typical) Passband Insertion Loss: 1 dB max. Passband IP3: +50 dBm (input, fo > 30 MHz) Tuning Control: 8 bit parallel Tuning Speed: 20 µS DC Power: +5 VDC @ 400 mA to 1.5 A Center Frequency Drift: 80 PPM/°C Operating Temperature Range: Size: -40° to +65°C 2.6 × 3.0 × 4.0 (in.) / 66.7 × 76.2 × 101.6 (mm.) Weight: POWER-POLE® NOTCH Filters offer improved performance and power handling over our MINI and MAXI NOTCH Filters. For interface and mechanical outline, please refer to the bandpass POWER-POLE® section on pages 30-33. 18.7 oz. / 530.1 g. / .5 kg. POWER-POLE® NOTCH Filters Product Number Selection Guide: Series Frequency (MHz) Notch Depth (dB) Options POWER-NOTCH 30-90 20 B C Available Options:B. Serial Interface C. Custom Frequency Bands (Specify START and STOP frequencies in MHz.) Note(s): Options may be limited to particular frequency bands and/or configurations. Consult factory for your application. Deutschland Telemeter Electronic GmbH Tel. +49 9 06 7 06 93-0 Fax +49 9 06 7 06 93-50 info@telemeter.de www.telemeter.info Schweiz Telemeter Electronic GmbH Tel. +41 71 6 99 20 20 Fax +41 71 6 99 20 24 info@telemeter.ch www.telemeter.info Tschechische Republik Telemeter Electronic s.r.o. Tel. +420 3 85 31 06 37 Fax +420 3 85 51 01 24 info@telemeter.cz www.telemeter.info Performance: The following plots illustrate approximate performance (not representative of all frequency ranges) POWER 30-90, 20 dB NOTCH (@ 30 MHz) POWER 30-90, 20 dB NOTCH (@ 60 MHz) 0 0 -3 -3 Insertion Loss (dB) Insertion Loss (dB) -6 -9 -12 -15 -18 -21 -6 -9 -12 -15 -18 -24 -21 -27 -24 -30 25 2627 28293031323334 35 -27 -30 Frequency (MHz) 55 5657 58596061626364 65 Frequency (MHz) POWER 30-90, 20 dB NOTCH (@ 90 MHz) 0 Insertion Loss (dB) -3 -6 -9 -12 -15 -18 -21 -24 -27 -30 85 8687 88899091929394 95 Frequency (MHz) Deutschland Telemeter Electronic GmbH Tel. +49 9 06 7 06 93-0 Fax +49 9 06 7 06 93-50 info@telemeter.de www.telemeter.info Schweiz Telemeter Electronic GmbH Tel. +41 71 6 99 20 20 Fax +41 71 6 99 20 24 info@telemeter.ch www.telemeter.info Tschechische Republik Telemeter Electronic s.r.o. Tel. +420 3 85 31 06 37 Fax +420 3 85 51 01 24 info@telemeter.cz www.telemeter.info Data is believed to be accurate. All data is subject to change without notice. Tunable Notch Filters Information/Quote Requests: Pre/Post-Selector Series PSEL1001 Specifications: Frequency Coverage: 1.5 to 30 MHz Input/Output Impedance: 50Ω Operation:Preselector Three Internal Bands:1.5 to 4 MHz, 4 to 10 MHz, 10 to 30 MHz 3 dB Bandwidth: 3 ± 0.5% Gain: 1 ± 2.5 dB Noise Figure: 11.5 dB (1.5 to 4 MHz) 10 dB (4 to 30 MHz) Inband RF Power Handling: Up to 1 Watt (input) Inband IP3: +27 to +34 dBm Tuning Control (751 Center Frequencies): 3 Wire Serial Tuning Speed: 10 to 200 µS Power: +5 VDC @ 30 to 800 mA +12 VDC @ 300 mA Center Frequency Drift: 80 PPM/°C Operating Temperature Range: Size: -40° to +85°C 1.5 × 3 × 5.8 (in.) / 38.1 × 76.2 × 146.1 (mm.) Weight: 1.4 lbs. / .65 kg. The PSEL1001 is an extremely versatile HF Preselector; it contains three MINI-POLE® filters covering the frequency ranges 1.5 to 4, 4 to 10 and 10 to 30 MHz. The internal switching network is accomplished using PIN diodes; thus, switching speed is fast and switching insertion loss is a low 0.6 dB. The PSEL1001 includes an amplifier to overcome filter loss. For the HF Preselector, the product of %BW x IL is typically equal to 20. This holds true across the entire tuning range of any internal filter band. PSEL1001 Product Number Selection Guide: Series Insertion Loss Bandwidth/IL PSEL1001 1.5-30 8 Deutschland Telemeter Electronic GmbH Tel. +49 9 06 7 06 93-0 Fax +49 9 06 7 06 93-50 info@telemeter.de www.telemeter.info Schweiz Telemeter Electronic GmbH Tel. +41 71 6 99 20 20 Fax +41 71 6 99 20 24 info@telemeter.ch www.telemeter.info 5206 37 Fax +420 3 85 51 01 24 info@telemeter.cz www.telemeter.info Tschechische Republik Telemeter Electronic s.r.o. Tel. +420 3 85 31 Serial Timing Diagram: Interface & Control Notes: Frequency Tuning Address The PSEL1001 utilizes an 11 bit scheme for tunewords to digitally control tuning of the center frequency for each of the filters bands (1.5 to 4, 4 to 10 and 10 to 30 MHz ) within this preselector. Strobe Note(s): 1. S erial data is clocked in on the positive edge of CLK. 2. Maximum CLK speed is 2 MHz. 3. Refer to Switching Characteristics Sheet for timing. The filter is tuned within 200 uSec for (1.5 to 4.0 MHz) and 100 uSec (4.0 to 10 MHz) and 10 uSec (10 to 30 MHz) to the frequency designated by the tuneword derived from the eleven bits clocked in when the Strobe line is brought low. Once strobed, data existing on the data lines is ignored until strobed again. Maximum strobe rate is 170 Hz for frequencies below 10 MHz. RF Power Handling Capability The filters are designed to operate with RF input power levels up to 1 Watt (+30 dBm) inband. Signals in the filter stop band up to 5 Watts at the input will not cause damage to the filter. Block Diagram: Pinout & Ratings: SERIAL INTERFACE PIN# Reference Designator Description 1 – N/C 2 – N/C 3 – N/C 4 – N/C 5 – N/C 6 – N/C 7 GND Ground 8 Vcc +5 VDC, 10% 9 GND Ground 10 – N/C 11 GND Ground 12 VDD +12 VDC, 5% 13 STB Strobe 14 SER CLK Serial Clock 15 DI Serial Data In Note: N/C = No Connect. Chassis Outline: Data is believed to be accurate. All data is subject to change without notice. Maximum Ratings 0 to +6 VDC 0 to +13 VDC 0 to +6 VDC Pre/Post-Selector Series Information/Quote Requests: Pre/Post-Selector Series PSEL1002 Specifications: Frequency Coverage: 2 to 2000 MHz (2 to 30 MHz bypass) Operation: Pre/post-selector filter/amplifier cascade Gain: Receive: Transmit: Receive Noise Figure: 7 dB 22 dB with tunable 1 dB steps of attenuation up to 19 dB 10 dB up to 1000 MHz 12 dB up to 2000 MHz Receive Input IP3: +13 dBm, (+2 dBm @ > 1 GHz) Transmit RF Output Power: Selectivity: 2 W up to 700 MHz 1 W > 700 MHz -27 dB @ ± 10% -50 dB @ ± 20% -65 dB @ ± 30% Spurious: -115 dBm Performance: 25 µS Power: +24V @ 500 mA +12V @ 350 mA +6.25V @ 1 A -12V @ 200 mA +95V @ 5 mA Operating Temperature Range: Size: -40° to +50°C 1.3 × 6.4 × 10 (in.) / 33 × 162.6 × 254 (mm.) Weight: Pre/Post-Selector Insertion Loss (dB) Tuning Speed: The PSEL1002 is a pre/post-selector that is an agile filter for operation from 30 MHz up to 2 GHz with a HF bypass mode. It enables simultaneous operation of multiple transceivers in extreme cosite environments. The pre/post-selector integrates numerous filters, LNAs and central control to achieve low noise signals with excellent selectivity for either transmit or receive applications. The highly miniaturized design is manufactured, aligned and tested using the latest state-of-the-art automatic technology. 3 lbs. / 1.36 kg. Note: Specifications are based on overall capabilities of most frequencies from 30 to 2000 MHz. PSEL1002 Product Number Selection Guide: Series Insertion Loss PSEL1002 TR-30-2000 Frequency (MHz) Note:a. 30-90 band c. 200-400 band e. 700-1000 band g. 1500-2000 band b. 90-200 band d. 400-700 band f. 1000-1500 band Deutschland Telemeter Electronic GmbH Tel. +49 9 06 7 06 93-0 Fax +49 9 06 7 06 93-50 info@telemeter.de www.telemeter.info Schweiz Telemeter Electronic GmbH Tel. +41 71 6 99 20 20 Fax +41 71 6 99 20 24 info@telemeter.ch www.telemeter.info Tschechische Republik Telemeter Electronic s.r.o. Tel. +420 3 85 31 06 37 Fax +420 3 85 51 01 24 info@telemeter.cz www.telemeter.info Chassis Outline: Block Diagram: Data is believed to be accurate. All data is subject to change without notice. Pre/Post-Selector Series Information/Quote Requests: