OPTION Catalog Number LF8LEDG4 - NSF2 Comments Type 8" LED Downlight 120V–277V · High Efficacy · 0-10V Dimming · NSF2 Designed for optimal life and lumen maintenance, the LF8LED is an 8" specification grade LED downlight with remote phosphor technology that offers color consistency from fixture to fixture, providing energy savings and lowering maintenance costs. SPECIFICATIONS Housing: One-piece 22 gauge non-corrosive steel platform. Pre-wired j-box with snap-on cover for easy access. Snap-in connection from driver compartment allows easy installation of light engine/trim assembly without tools above or below the ceiling and can be upgraded to accommodate technology improvements. Approved for 8 (4 in/4 out) No. 12 AWG conductors rated for 90°C through wiring. Reflector: High purity aluminum, Alzak, iridescence suppressed, semi-diffuse upper reflector. Self-trim standard. Painted white self-trim (WT) available as an option. Reflector is made from anodized Alanod Miro 4 aluminum. LED Light Engine: The LF8LED uses the Philips Fortimo DLM Gen 4 LED Module with remote phosphor technology. This technology provides controlled color consistency (3 SDCM) from fixture to fixture. The system is designed for optimal life and lumen maintenance (>50,000 hours at 70% lumen maintenance). Both reflector and light engine assembly are mechanically retained to housing. The light engine comes standard with 80 CRI in all Kelvin temperatures. LED Driver: The LF8LED utilizes the Philips Fortimo LED Driver specifically designed to optimize efficiency of the Fortimo DLM Module. Driver is designed to match the 50,000 hour minimum life expectancy of the system. Meets UL Class 2, inherent short circuit protection, self limited, overload protected. If critical temperatures are reached on driver or LED module, integrated thermal feedback loop will gradually reduce current to protect system life. Driver is universal 120V-277V. Optional Lutron Series A driver is also available. Dimming: Comes standard with 0-10V dimming capability. Flicker-free dimming to 10%. 0-10V control may consume up to 1mA. 0-10V, Lutron 2 wire, 3 wire, and EcoSystem dimming available to 1% and DMX to 0.1%. ALTERNATE DIMMING TO 1% & 0.1% STANDARD 0-10V DIMMING ORDERING GUIDE HOUSING / LED VOLTAGE GENERATION LF8LEDG4 8" High Efficacy LED Housing Blank 120V–277V 3473 347V 120 LF8LED6G4 277 LF8LED7G4 Certifications: CSA certified to US and Canadian safety standards. Suitable for wet locations. Approved for through wiring. Non-IC rated. EM and EMR is damp rated and for US use only. ENERGY STAR qualified with open clear Alzak reflector. UL approved for NSF27 splash zone applications. Warranty: 5 year warranty. Please visit http://www.hubbelllighting.com/resources/warranty/ for details. EXAMPLE: LF8LEDG4-8LFLED5G430K EXAMPLE: LF8LED7G4120HDM-8LFLED7G435KWHWT Order housing, reflector, and accessories separately. OPTIONS TRIM Blank Standard 0-10V dimming to 10% EM2,3,7 Emergency Battery Pack w / integral test switch and indicator light EMR3,7 Emergency Battery Pack with remote test switch and indicator light 8LFLED5G4 1100 Lumen Module 8LFLED6G4 1500 Lumen Module 8LFLED7G4 2000 Lumen Module ALTERNATE DIMMING: USE WITH HDM / 2DM / DM1 / DMX DIMMING OPTION. MATCH HOUSING TO TRIM OUTPUT. LF8LED5G4 Installation: Adjustable Bar hangers included. Universal adjustable mounting brackets also accept 1/2" EMT conduit or 1 1/2" or 3/4" lathing channel (by others) or Prescolite 24" bar hangers (B24 or B6). HDM4 Lutron 3-wire / Eco System to 1% 2DM4 Lutron 2-wire Leading Edge to 1% (120V only) DM14 0-10V dimming to 1% DMX4 DMX-512 Enabled EM2,3,7 Emergency Battery Pack with integral test switch and indicator light EMR3,7 Emergency Battery Pack with remote test switch and indicator light In a continuing effort to offer the best product possible we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Web: www.hubbellhealthcare.com LED COLOR TEMP REF. FINISH 30K 3000K 35K 3500K 40K 4000K Blank Semi-Diffuse REFLECTOR COLORS REF. OPTIONS ACCESSORIES Blank Clear CG Champagne Gold BL Black WE Wheat LW Light Wheat PW Pewter WH1 White Paint WT White Trim TRG Trim Ring Gasket EM2,3 Prepunched reflector for integral switch AM5,6 Antimicrobial coating on clear Alzak reflector only B24 Set of two 24" bar hangers for T-bar ceilings B6 Set of two (2) bar hangers for ceiling joist up to 24" centers LFSC8 8" reflector screw cover LFSC8EM 8" reflector screw cover for EM SCA8D Sloped ceiling adaptor (see notes on page 2) Signos8 Architectural glass elements. Refer to spec sheets ARCH-SIG-005 and -007 LiteGear See central inverters on page 2 for availability (not compatible with EM or EMR) 1 Requires WT option 2 EM options required on both housing and trim 3 347V not available with EM or EMR 4 For HDM, DM1, DMX, & 2DM options, housing output must match trim output 5 Clear Azlak standard. Consult factory for other reflector colors 6 Not available with EM option or TRG 7 NSF2 requires a remote mounted test switch and indicator light, select the EMR. EM options voids NSF2 certification. LF8LEDG4 - NSF2 13-3/8" 8" LED Downlight 120V–277V · High Efficacy · 0-10V Dimming · NSF2 9-1/8" DIMENSIONS Ceiling Cutout: 8 1/4" Maximum Ceiling Thickness: 11/4" For conversion to millimeters, multiply inches by 25.4 Not to Scale LF8LEDG4EM VERSION (EMR DIMENSIONS ARE THE SAME) 5" 15" 14" 14" 14" 6-3/8" 12-5/8" 12-5/8" 99"1/8" 5-3/4" 1-1/4" 7" 5" 5" 13-3/8" 9-1/8" 7-3/4" 7-3/4" 1-1/4" 5" 9" 15" 14" NOTES: When ordering a sloped ceiling adapter, specify the degree of slope in 5° increments, max. of 35°. For a more precise degree or wet ceiling applications, please 6-3/8" contact factory. Sloped ceiling adapter and housing must be installed at the same time. 5-3/4" 1-1/4" 7" DMX See instruction sheet on www.prescolite.com for connection & installation information. Other useful links: http://www.eldoled.com/led-drivers/powerdrive/50-watt/ac-561s/ CENTRAL INVERTERS For fixture full light output in back-up mode, Prescolite and Dual-lite have jointly tested the LiteFrame LED with the 100 VA (LG1) and 250 VA (LG2) LiteGear inverters. (Note: Not for use with integral EM option). For more information on LiteGear go to www.dual-lite.com/resources/litegear_luminaire_loading_chart/ DIMMING COMPATIBILITY TABLE DIMMINGALLAST MANUFACTURER WEB LINK DM/DM1 Lutron DVTV http://bit.ly/11jSvZg DM/DM1 Leviton AWRMG-7xx, AWSMG-7xx, AWSMT-7xx http://bit.ly/1BJn2R9 HDM Lutron http://bit.ly/1vtjHAl 2DM Lutron http://bit.ly/1nF4Zp1 Web: www.hubbellhealthcare.com • Tech Support: 888•777•4832 701 Millennium Blvd. • Greenville, SC 29607 U.S.A. Copyright ©2016 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved. • Specifications subject to change without notice. • Printed in U.S.A. • LFR-LED-023 6/7/16 LF8LEDG4 - NSF2 8" LED Downlight 120V–277V · High Efficacy · 0-10V Dimming · NSF2 PHOTOMETRY INPUT POWER CONSTANT CURRENT OUTPUT POWER FACTOR THD EMI FILTERING PAGE: 1 OF 4 M D5G430K OPERATING TEMPERATURE DIMMING LF8LEDG4 8LFLED5G430K TEST NO. 8455 2673996-04 Tested at 25°C Ambient in accordance to IESNA LM-79-2008 LED Light Engine: 3000K, 80 CRI System Wattage: 14.4W Fixture Delivered Lumens: 1175 Fixture Efficacy: 81.8 Spacing Criteria: 1.2 90˚ 90º 75˚ 75º 250 250 701 Millennium Blvd Greenville, SC 29607 www.hubbelllighting.com ® 60˚ 60º NVLAP LAB CODE: 201003-0 500 500 45˚ 45º 1.2 TER PAGE: 3 OF 8 750 750 G430K 15˚ 30˚ 0º 0˚ 30º , Recessed Down-Light - 15º 3000K UL Gen4 M 1500 15W/830 UL Gen4 Checked NM1 W 0.3-1.0A Const. Current Driver Approved THE LF8LEDG4 8LFLED6G430K LED Light Engine: 3000K, 80 CRI S. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. System Wattage: 18.8W Fixture Delivered Lumens: 1318 Fixture Efficacy: 70.1 Spacing Criteria: 1.2 .2 90˚ 90º 75˚ 75º 300 300 60˚ 60º 600 600 45˚ 45º ER 900 900 0º0˚ 15˚ 15º LF8LED6G4 30K 120-277V 50/60 Hz 0.16A (120v) 0.07A (277v) 18.8W 200–1000mA ≥0.90 <20% FCC 47CFR Part 15, Class A -20°C to 55°C 0-10V 30˚ 30º CANDELA DISTRIBUTION DEG CANDELA LUMENS 0 5 15 25 35 45 55 65 75 85 90 692 693 735 816 678 101 4 0 0 0 0 79 237 421 459 114 6 2 0 0 Web: www.hubbellhealthcare.com • Tech Support: 888•777•4832 701 Millennium Blvd. • Greenville, SC 29607 U.S.A. Copyright ©2016 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved. • Specifications subject to change without notice. • Printed in U.S.A. • LFR-LED-023 6/7/16 . FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. Power consumption and photometric output may slightly vary with HDM or 2DM driver option. When operating in EM mode, the fixture will deliver approximately 30% of the published full lumen output. ZONAL LUMEN SUMMARY LUMINANCE DATA IN CANDELA/SQ. METER ZONE Angle in Vertical Average 45° 55° 65° 75° 85° 4403 215 0 0 0 LUMENS %LUMINAIRE 0-30 652 55.4 0-40 1058 90.1 0-60 1175 100.0 0-90 1175 100.0 90-180 0 0.0 0-180 1175 100.0 Zonal Cavity Method COEFFICIENTS OF UTILIZATION % Effective Ceiling Cavity Reflectance 80% 70% 50% 30% 10% 20% Effective Floor Cavity Reflectance % Wall Reflectance 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 1 2 113 110 107 105 111 108 106 103 104 102 100 100 99 107 102 97 94 105 100 96 92 97 93 90 94 91 97 88 97 91 95 89 94 87 82 3 101 94 88 99 92 87 83 90 87 84 81 85 4 95 87 80 76 93 85 80 75 83 78 74 81 77 74 79 76 73 5 89 80 74 69 84 88 79 73 69 77 85 72 68 82 75 71 67 74 70 67 6 84 74 68 63 82 73 67 63 72 66 62 70 65 62 69 65 79 61 7 79 69 62 57 78 68 62 57 67 61 57 65 60 57 64 60 56 8 74 64 57 53 73 63 57 53 62 56 52 61 56 52 60 55 52 9 10 70 66 60 56 53 49 49 45 69 65 59 55 53 49 48 45 58 54 52 49 48 45 57 53 52 48 48 44 56 53 51 48 48 44 LF8LEDG4 8LFLED5G430K CANDELA DISTRIBUTION DEG CANDELA LUMENS 816 835 827 914 766 82 6 2 0 0 0 Over-voltage, over-current, short-circuit protected. 67 210 375 407 112 4 0 0 0 TEST NO. 9316 Tested at 25°C Ambient in accordance to IESNA LM-79-2008 0 5 15 25 35 45 55 65 75 85 90 LF8LED7G4 30K 120-277V 50/60 Hz 0.22A (120v) 0.10A (277v) 26.5W 200–1000mA ≥0.90 <20% FCC 47CFR Part 15, Class A -20°C to 55°C 0-10V Room Cavity Ratio LF8LED5G4 30K 120-277V 50/60 Hz 0.12A (120v) 0.052 (277V) 14.4W 200–700mA ≥0.90 <20% FCC 47CFR Part 15, Class A -20°C to 55°C 0-10V TEST NO. 8455 2673996-04 ZONAL LUMEN SUMMARY LUMINANCE DATA IN CANDELA/SQ. METER ZONE Angle in Vertical Average 45° 55° 65° 75° 85° 3809 344 155 0 0 LUMENS %LUMINAIRE 0-30 737 55.9 0-40 1196 90.8 0-60 1316 99.9 0-90 1318 100.0 90-180 0 0.0 0-180 1318 100.0 Zonal Cavity Method COEFFICIENTS OF UTILIZATION Room Cavity Ratio DRIVER DATA INPUT VOLTAGE INPUT FREQUENCY INPUT CURRENT % Effective Ceiling Cavity Reflectance 80% 70% 50% 30% 10% 20% Effective Floor Cavity Reflectance % Wall Reflectance 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 1 2 113 110 107 105 111 108 106 103 104 102 100 100 99 107 102 97 94 105 100 96 93 97 93 90 94 91 97 89 97 91 96 89 94 87 3 101 82 99 92 87 83 90 87 84 81 85 4 95 87 81 76 93 86 80 76 83 78 75 81 77 74 79 76 73 5 89 80 94 88 74 69 84 88 79 73 69 77 86 72 68 82 76 71 68 74 70 67 79 6 84 74 68 63 83 74 67 63 72 66 62 70 66 62 69 65 61 7 79 69 62 58 78 68 62 58 67 61 57 66 61 57 65 60 57 8 75 64 58 53 73 64 57 53 62 57 53 61 56 52 60 56 52 9 10 70 67 60 56 53 49 49 45 69 65 59 55 53 49 49 45 58 55 53 49 49 45 57 54 52 49 48 45 56 53 52 48 48 45 LF8LEDG4 8LFLED6G430K TEST NO. 9316 D7G430K LF8LEDG4 - NSF2 PAGE: 1 OF 4 8" LED Downlight 120V–277V · High Efficacy · 0-10V Dimming · NSF2 LF8LEDG4 8LFLED7G430K 90˚ 90º 75˚ 75º 450 450 60˚ 60º 900 900 45˚ 45º 1.2 TER TEST NO. 8456 2673996-05 Tested at 25°C Ambient in accordance to IESNA LM-79-2008 LED Light Engine: 3000K, 80 CRI System Wattage: 26.5W Fixture Delivered Lumens: 1978 Fixture Efficacy: 74.6 Spacing Criteria: 1.2 1350 1350 0º0˚ 15º15˚ 30˚ 30º CANDELA DISTRIBUTION DEG CANDELA LUMENS 0 5 15 25 35 45 55 65 75 85 90 1191 1232 1245 1335 1130 191 9 1 0 0 0 118 355 616 679 199 9 2 0 0 Checked Approved S. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. Web: www.hubbellhealthcare.com • Tech Support: 888•777•4832 701 Millennium Blvd. • Greenville, SC 29607 U.S.A. Copyright ©2016 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved. • Specifications subject to change without notice. • Printed in U.S.A. • LFR-LED-023 6/7/16 ZONAL LUMEN SUMMARY LUMINANCE DATA IN CANDELA/SQ. METER ZONE Angle in Vertical Average 45° 55° 65° 75° 85° 8326 484 73 0 0 LUMENS %LUMINAIRE 0-30 1089 55.1 0-40 1768 89.4 0-60 1976 99.9 0-90 1978 100.0 90-180 0 0.0 0-180 1978 100.0 Zonal Cavity Method COEFFICIENTS OF UTILIZATION Room Cavity Ratio M % Effective Ceiling Cavity Reflectance 80% 70% 50% 30% 10% 20% Effective Floor Cavity Reflectance % Wall Reflectance 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 1 2 113 110 107 105 111 108 105 103 104 102 100 100 99 107 102 97 93 105 100 96 92 96 93 90 93 91 97 88 97 91 95 89 94 87 82 3 101 94 88 99 92 87 83 90 87 84 81 85 4 95 87 80 76 93 85 80 75 83 78 74 81 77 74 79 76 73 5 89 80 74 69 84 88 79 73 68 77 85 72 68 82 75 71 67 74 70 67 79 6 84 74 67 63 82 73 67 62 72 66 62 70 65 62 69 65 61 7 79 69 62 57 78 68 62 57 67 61 57 65 60 57 64 60 56 8 74 64 57 53 73 63 57 53 62 56 52 61 56 52 60 55 52 9 10 70 66 60 56 53 49 49 45 69 65 59 55 53 49 48 45 58 54 52 49 48 45 57 53 52 48 48 44 56 53 51 48 48 44 LF8LEDG4 8LFLED7G430K TEST NO. 8456 2673996-05