LF8LEDG4 - NSF2 - Hubbell Healthcare Solutions

OPTION
Catalog Number
LF8LEDG4 - NSF2
Comments
Type
8" LED Downlight
120V–277V · High Efficacy · 0-10V Dimming · NSF2
Designed for optimal life and lumen maintenance, the LF8LED is an 8" specification
grade LED downlight with remote phosphor technology that offers color consistency
from fixture to fixture, providing energy savings and lowering maintenance costs.
SPECIFICATIONS
Housing: One-piece 22 gauge non-corrosive steel platform. Pre-wired j-box with
snap-on cover for easy access. Snap-in connection from driver compartment
allows easy installation of light engine/trim assembly without tools above or below
the ceiling and can be upgraded to accommodate technology improvements.
Approved for 8 (4 in/4 out) No. 12 AWG conductors rated for 90°C through wiring.
Reflector: High purity aluminum, Alzak, iridescence suppressed, semi-diffuse
upper reflector. Self-trim standard. Painted white self-trim (WT) available as an
option. Reflector is made from anodized Alanod Miro 4 aluminum.
LED Light Engine: The LF8LED uses the Philips Fortimo DLM Gen 4 LED Module
with remote phosphor technology. This technology provides controlled color
consistency (3 SDCM) from fixture to fixture. The system is designed for optimal life
and lumen maintenance (>50,000 hours at 70% lumen maintenance). Both reflector
and light engine assembly are mechanically retained to housing. The light engine
comes standard with 80 CRI in all Kelvin temperatures.
LED Driver: The LF8LED utilizes the Philips Fortimo LED Driver specifically
designed to optimize efficiency of the Fortimo DLM Module. Driver is designed
to match the 50,000 hour minimum life expectancy of the system. Meets UL
Class 2, inherent short circuit protection, self limited, overload protected. If critical
temperatures are reached on driver or LED module, integrated thermal feedback
loop will gradually reduce current to protect system life. Driver is universal
120V-277V. Optional Lutron Series A driver is also available.
Dimming: Comes standard with 0-10V dimming capability. Flicker-free dimming
to 10%. 0-10V control may consume up to 1mA. 0-10V, Lutron 2 wire, 3 wire, and
EcoSystem dimming available to 1% and DMX to 0.1%.
ALTERNATE DIMMING TO 1% & 0.1%
STANDARD 0-10V DIMMING
ORDERING GUIDE
HOUSING / LED VOLTAGE
GENERATION
LF8LEDG4
8" High Efficacy
LED Housing
Blank
120V–277V
3473
347V
120
LF8LED6G4
277
LF8LED7G4
Certifications: CSA certified to US and Canadian safety standards. Suitable for wet
locations. Approved for through wiring. Non-IC rated. EM and EMR is damp rated
and for US use only. ENERGY STAR qualified with open clear Alzak reflector. UL
approved for NSF27 splash zone applications.
Warranty: 5 year warranty. Please visit
http://www.hubbelllighting.com/resources/warranty/ for details.
EXAMPLE: LF8LEDG4-8LFLED5G430K
EXAMPLE: LF8LED7G4120HDM-8LFLED7G435KWHWT
Order housing, reflector, and accessories separately.
OPTIONS
TRIM
Blank
Standard 0-10V dimming to 10%
EM2,3,7
Emergency Battery Pack w / integral
test switch and indicator light
EMR3,7
Emergency Battery Pack with remote
test switch and indicator light
8LFLED5G4
1100 Lumen
Module
8LFLED6G4
1500 Lumen
Module
8LFLED7G4
2000 Lumen
Module
ALTERNATE DIMMING: USE WITH HDM / 2DM / DM1 / DMX
DIMMING OPTION. MATCH HOUSING TO TRIM OUTPUT.
LF8LED5G4
Installation: Adjustable Bar hangers included. Universal adjustable mounting
brackets also accept 1/2" EMT conduit or 1 1/2" or 3/4" lathing channel (by others) or
Prescolite 24" bar hangers (B24 or B6).
HDM4
Lutron 3-wire / Eco System to 1%
2DM4
Lutron 2-wire Leading Edge to 1% (120V only)
DM14
0-10V dimming to 1%
DMX4
DMX-512 Enabled
EM2,3,7
Emergency Battery Pack with
integral test switch and indicator
light
EMR3,7
Emergency Battery Pack with remote
test switch and indicator light
In a continuing effort to offer the best product possible we reserve the right to change, without
notice, specifications or materials that in our opinion will not alter the function of the product.
Web: www.hubbellhealthcare.com
LED COLOR
TEMP
REF. FINISH
30K
3000K
35K
3500K
40K
4000K
Blank
Semi-Diffuse
REFLECTOR
COLORS
REF. OPTIONS
ACCESSORIES
Blank
Clear
CG
Champagne Gold
BL
Black
WE
Wheat
LW
Light Wheat
PW
Pewter
WH1
White Paint
WT
White Trim
TRG
Trim Ring Gasket
EM2,3
Prepunched reflector for
integral switch
AM5,6
Antimicrobial coating on
clear Alzak reflector only
B24
Set of two 24" bar hangers
for T-bar ceilings
B6
Set of two (2) bar hangers
for ceiling joist up to 24"
centers
LFSC8
8" reflector screw cover
LFSC8EM
8" reflector screw cover
for EM
SCA8D
Sloped ceiling adaptor
(see notes on page 2)
Signos8
Architectural glass
elements. Refer to spec
sheets ARCH-SIG-005
and -007
LiteGear
See central inverters on
page 2 for availability
(not compatible with EM
or EMR)
1
Requires WT option
2
EM options required on both housing and trim
3
347V not available with EM or EMR
4
For HDM, DM1, DMX, & 2DM options, housing output must
match trim output
5
Clear Azlak standard. Consult factory for other reflector colors
6
Not available with EM option or TRG
7
NSF2 requires a remote mounted test switch and indicator
light, select the EMR. EM options voids NSF2 certification.
LF8LEDG4 - NSF2
13-3/8"
8" LED Downlight
120V–277V · High Efficacy · 0-10V Dimming · NSF2
9-1/8"
DIMENSIONS
Ceiling Cutout: 8 1/4"
Maximum Ceiling Thickness: 11/4"
For conversion to millimeters, multiply inches by 25.4
Not to Scale
LF8LEDG4EM VERSION (EMR DIMENSIONS ARE THE SAME)
5"
15"
14"
14"
14"
6-3/8"
12-5/8"
12-5/8"
99"1/8"
5-3/4"
1-1/4"
7"
5"
5"
13-3/8"
9-1/8"
7-3/4"
7-3/4"
1-1/4"
5"
9"
15"
14"
NOTES: When ordering a sloped ceiling adapter, specify the degree of slope in 5°
increments, max. of 35°. For a more precise degree or wet ceiling applications, please
6-3/8"
contact factory. Sloped ceiling adapter and housing must be installed at the same time.
5-3/4"
1-1/4"
7"
DMX
See instruction sheet on www.prescolite.com for connection & installation information. Other useful links: http://www.eldoled.com/led-drivers/powerdrive/50-watt/ac-561s/
CENTRAL INVERTERS
For fixture full light output in back-up mode, Prescolite and Dual-lite have jointly tested the LiteFrame LED with the 100 VA (LG1) and 250 VA (LG2) LiteGear inverters.
(Note: Not for use with integral EM option). For more information on LiteGear go to www.dual-lite.com/resources/litegear_luminaire_loading_chart/
DIMMING COMPATIBILITY TABLE
DIMMINGALLAST MANUFACTURER
WEB LINK
DM/DM1
Lutron DVTV
http://bit.ly/11jSvZg
DM/DM1
Leviton AWRMG-7xx, AWSMG-7xx, AWSMT-7xx
http://bit.ly/1BJn2R9
HDM
Lutron
http://bit.ly/1vtjHAl
2DM
Lutron
http://bit.ly/1nF4Zp1
Web: www.hubbellhealthcare.com • Tech Support: 888•777•4832
701 Millennium Blvd. • Greenville, SC 29607 U.S.A.
Copyright ©2016 Prescolite, Inc., a division of Hubbell Lighting, Inc.
All Rights Reserved. • Specifications subject to change without notice. • Printed in U.S.A. • LFR-LED-023 6/7/16
LF8LEDG4 - NSF2
8" LED Downlight
120V–277V · High Efficacy · 0-10V Dimming · NSF2
PHOTOMETRY
INPUT POWER
CONSTANT CURRENT OUTPUT
POWER FACTOR
THD
EMI FILTERING PAGE: 1 OF 4
M
D5G430K
OPERATING TEMPERATURE
DIMMING
LF8LEDG4 8LFLED5G430K
TEST NO. 8455 2673996-04
Tested at 25°C Ambient in accordance to
IESNA LM-79-2008
LED Light Engine: 3000K, 80 CRI
System Wattage: 14.4W
Fixture Delivered Lumens: 1175
Fixture Efficacy: 81.8
Spacing Criteria: 1.2
90˚
90º
75˚
75º
250
250
701 Millennium Blvd
Greenville, SC 29607
www.hubbelllighting.com
®
60˚
60º
NVLAP LAB CODE: 201003-0
500
500
45˚
45º
1.2
TER
PAGE: 3 OF 8
750
750
G430K
15˚
30˚
0º 0˚
30º
, Recessed Down-Light
- 15º
3000K
UL Gen4
M 1500 15W/830 UL
Gen4
Checked
NM1
W 0.3-1.0A Const.
Current Driver
Approved
THE
LF8LEDG4 8LFLED6G430K
LED Light Engine: 3000K, 80 CRI
S. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
System Wattage: 18.8W
Fixture Delivered Lumens: 1318
Fixture Efficacy: 70.1
Spacing Criteria: 1.2
.2
90˚
90º
75˚
75º
300
300
60˚
60º
600
600
45˚
45º
ER
900
900
0º0˚
15˚
15º
LF8LED6G4 30K
120-277V
50/60 Hz
0.16A (120v)
0.07A (277v)
18.8W
200–1000mA
≥0.90
<20%
FCC 47CFR
Part 15, Class A
-20°C to 55°C
0-10V
30˚
30º
CANDELA DISTRIBUTION
DEG
CANDELA LUMENS
0
5
15
25
35
45
55
65
75
85
90
692
693
735
816
678
101
4
0
0
0
0
79
237
421
459
114
6
2
0
0
Web: www.hubbellhealthcare.com • Tech Support: 888•777•4832
701 Millennium Blvd. • Greenville, SC 29607 U.S.A.
Copyright ©2016 Prescolite, Inc., a division of Hubbell Lighting, Inc.
All Rights Reserved. • Specifications subject to change without notice. • Printed in U.S.A. • LFR-LED-023 6/7/16
. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
Power consumption and photometric output may slightly
vary with HDM or 2DM driver option.
When operating in EM mode, the fixture will deliver
approximately 30% of the published full lumen output.
ZONAL LUMEN SUMMARY
LUMINANCE DATA IN CANDELA/SQ. METER
ZONE
Angle in Vertical
Average
45°
55°
65°
75°
85°
4403
215
0
0
0
LUMENS
%LUMINAIRE
0-30
652
55.4
0-40
1058
90.1
0-60
1175
100.0
0-90
1175
100.0
90-180
0
0.0
0-180
1175
100.0
Zonal Cavity Method
COEFFICIENTS OF UTILIZATION
% Effective Ceiling Cavity Reflectance
80%
70%
50%
30%
10%
20% Effective Floor Cavity Reflectance
% Wall Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10
50 30
10
1
2
113 110 107 105 111 108 106 103 104 102 100 100 99
107 102 97 94 105 100 96 92 97 93 90 94 91
97
88
97
91
95
89
94
87
82
3
101
94
88
99
92
87
83
90
87
84
81
85
4
95
87
80
76
93
85
80
75
83
78
74
81
77
74
79
76
73
5
89
80
74
69
84
88
79
73
69
77
85
72
68
82
75
71
67
74
70
67
6
84
74
68
63
82
73
67
63
72
66
62
70
65
62
69
65
79
61
7
79
69
62
57
78
68
62
57
67
61
57
65
60
57
64
60
56
8
74
64
57
53
73
63
57
53
62
56
52
61
56
52
60
55
52
9
10
70
66
60
56
53
49
49
45
69
65
59
55
53
49
48
45
58
54
52
49
48
45
57
53
52
48
48
44
56
53
51
48
48
44
LF8LEDG4 8LFLED5G430K
CANDELA DISTRIBUTION
DEG
CANDELA LUMENS
816
835
827
914
766
82
6
2
0
0
0
Over-voltage, over-current, short-circuit protected.
67
210
375
407
112
4
0
0
0
TEST NO. 9316
Tested at 25°C Ambient in accordance to
IESNA LM-79-2008
0
5
15
25
35
45
55
65
75
85
90
LF8LED7G4 30K
120-277V
50/60 Hz
0.22A (120v)
0.10A (277v)
26.5W
200–1000mA
≥0.90
<20%
FCC 47CFR
Part 15, Class A
-20°C to 55°C
0-10V
Room Cavity
Ratio
LF8LED5G4 30K
120-277V
50/60 Hz
0.12A (120v)
0.052 (277V)
14.4W
200–700mA
≥0.90
<20%
FCC 47CFR
Part 15, Class A
-20°C to 55°C
0-10V
TEST NO. 8455 2673996-04
ZONAL LUMEN SUMMARY
LUMINANCE DATA IN CANDELA/SQ. METER
ZONE
Angle in Vertical
Average
45°
55°
65°
75°
85°
3809
344
155
0
0
LUMENS
%LUMINAIRE
0-30
737
55.9
0-40
1196
90.8
0-60
1316
99.9
0-90
1318
100.0
90-180
0
0.0
0-180
1318
100.0
Zonal Cavity Method
COEFFICIENTS OF UTILIZATION
Room Cavity
Ratio
DRIVER DATA
INPUT VOLTAGE
INPUT FREQUENCY
INPUT CURRENT
% Effective Ceiling Cavity Reflectance
80%
70%
50%
30%
10%
20% Effective Floor Cavity Reflectance
% Wall Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10
50 30
10
1
2
113 110 107 105 111 108 106 103 104 102 100 100 99
107 102 97 94 105 100 96 93 97 93 90 94 91
97
89
97
91
96
89
94
87
3
101
82
99
92
87
83
90
87
84
81
85
4
95
87
81
76
93
86
80
76
83
78
75
81
77
74
79
76
73
5
89
80
94
88
74
69
84
88
79
73
69
77
86
72
68
82
76
71
68
74
70
67
79
6
84
74
68
63
83
74
67
63
72
66
62
70
66
62
69
65
61
7
79
69
62
58
78
68
62
58
67
61
57
66
61
57
65
60
57
8
75
64
58
53
73
64
57
53
62
57
53
61
56
52
60
56
52
9
10
70
67
60
56
53
49
49
45
69
65
59
55
53
49
49
45
58
55
53
49
49
45
57
54
52
49
48
45
56
53
52
48
48
45
LF8LEDG4 8LFLED6G430K
TEST NO. 9316
D7G430K
LF8LEDG4 - NSF2
PAGE: 1 OF 4
8" LED Downlight
120V–277V · High Efficacy · 0-10V Dimming · NSF2
LF8LEDG4 8LFLED7G430K
90˚
90º
75˚
75º
450
450
60˚
60º
900
900
45˚
45º
1.2
TER
TEST NO. 8456 2673996-05
Tested at 25°C Ambient in accordance to
IESNA LM-79-2008
LED Light Engine: 3000K, 80 CRI
System Wattage: 26.5W
Fixture Delivered Lumens: 1978
Fixture Efficacy: 74.6
Spacing Criteria: 1.2
1350
1350
0º0˚
15º15˚
30˚
30º
CANDELA DISTRIBUTION
DEG
CANDELA LUMENS
0
5
15
25
35
45
55
65
75
85
90
1191
1232
1245
1335
1130
191
9
1
0
0
0
118
355
616
679
199
9
2
0
0
Checked
Approved
S. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
Web: www.hubbellhealthcare.com • Tech Support: 888•777•4832
701 Millennium Blvd. • Greenville, SC 29607 U.S.A.
Copyright ©2016 Prescolite, Inc., a division of Hubbell Lighting, Inc.
All Rights Reserved. • Specifications subject to change without notice. • Printed in U.S.A. • LFR-LED-023 6/7/16
ZONAL LUMEN SUMMARY
LUMINANCE DATA IN CANDELA/SQ. METER
ZONE
Angle in Vertical
Average
45°
55°
65°
75°
85°
8326
484
73
0
0
LUMENS
%LUMINAIRE
0-30
1089
55.1
0-40
1768
89.4
0-60
1976
99.9
0-90
1978
100.0
90-180
0
0.0
0-180
1978
100.0
Zonal Cavity Method
COEFFICIENTS OF UTILIZATION
Room Cavity
Ratio
M
% Effective Ceiling Cavity Reflectance
80%
70%
50%
30%
10%
20% Effective Floor Cavity Reflectance
% Wall Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10
50 30
10
1
2
113 110 107 105 111 108 105 103 104 102 100 100 99
107 102 97 93 105 100 96 92 96 93 90 93 91
97
88
97
91
95
89
94
87
82
3
101
94
88
99
92
87
83
90
87
84
81
85
4
95
87
80
76
93
85
80
75
83
78
74
81
77
74
79
76
73
5
89
80
74
69
84
88
79
73
68
77
85
72
68
82
75
71
67
74
70
67
79
6
84
74
67
63
82
73
67
62
72
66
62
70
65
62
69
65
61
7
79
69
62
57
78
68
62
57
67
61
57
65
60
57
64
60
56
8
74
64
57
53
73
63
57
53
62
56
52
61
56
52
60
55
52
9
10
70
66
60
56
53
49
49
45
69
65
59
55
53
49
48
45
58
54
52
49
48
45
57
53
52
48
48
44
56
53
51
48
48
44
LF8LEDG4 8LFLED7G430K
TEST NO. 8456 2673996-05