Lighting Sciences Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 • Fax: 480-991-0375 www.lightingsciences.com CERTIFIED TEST REPORT No. 26993 RAB LIGHTING - LED OUTDOOR LUMINAIRE,CAT# HBLED10 WITH SPECULAR FLOOD REFLECTOR AND CLEAR FLAT GLASS LENS ONE LED ARRAY. LUMINAIRE OUTPUT = 338 LMS. LUMINAIRE OPERATING AT 120 VAC AND 13.3 WATTS INTENSITY(CANDLEPOWER) SUMMARY ANGLE 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 MEAN CP 279 272 260 246 227 208 190 166 112 34 24 14 4 0 0 0 0 0 0 LUMENS 26 69 96 100 35 12 1 0 0 ZONAL LUMENS AND PERCENTAGES ZONE 0-30 0-40 0-60 0-90 40-90 60-90 90-180 0-180 LUMENS 190 290 337 338 48 1 0 338 % LUMINAIRE 56.31 85.74 99.73 100.00 14.26 0.27 0.00 100.00 EFFICACY (LUMENS PER WATT): 25.4 *** THIS IS AN ABSOLUTE TEST *** LUMINOUS DIAMETER: 6.000 INS LUMINANCE SUMMARY CD./SQ.M. ANGLE 45 55 65 75 85 MEAN CD/SQ M 2626 1297 28 21 27 CERTIFIED BY: PREPARED FOR: RAB LIGHTING NORTHVALE, NJ S/MH: SC: 1.0 1.0 DATE: APR 22, 2010 TESTED IN ACCORDANCE WITH IES PROCEDURES. LIGHTING SCIENCES, INC. 7826 E. EVANS RD. SCOTTSDALE, AZ, USA 85260 CERTIFIED TEST REPORT No. 26993 RAB LIGHTING - LED OUTDOOR LUMINAIRE,CAT# HBLED10 WITH SPECULAR FLOOD REFLECTOR AND CLEAR FLAT GLASS LENS ONE LED ARRAY. LUMINAIRE OUTPUT = 338 LMS. LUMINAIRE OPERATING AT 120 VAC AND 13.3 WATTS INTENSITY(CANDLEPOWER) DATA IN 2.5 DEGREE STEPS ANGLE 0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0 37.5 40.0 42.5 45.0 47.5 50.0 52.5 55.0 57.5 60.0 62.5 65.0 67.5 70.0 72.5 75.0 77.5 80.0 82.5 85.0 87.5 90.0 INTENSITY LUMENS (CANDLEPOWER) 279 277 272 266 260 254 246 238 227 217 208 199 190 180 166 144 112 57 34 29 24 19 14 8 4 1 0 0 0 0 0 0 0 0 0 0 0 26 69 96 100 35 12 1 0 0 LIGHTING SCIENCES, INC. 7826 E. EVANS RD. SCOTTSDALE, AZ, USA 85260 CERTIFIED TEST REPORT No. 26993 RAB LIGHTING - LED OUTDOOR LUMINAIRE,CAT# HBLED10 WITH SPECULAR FLOOD REFLECTOR AND CLEAR FLAT GLASS LENS ONE LED ARRAY. LUMINAIRE OUTPUT = 338 LMS. LUMINAIRE OPERATING AT 120 VAC AND 13.3 WATTS AVERAGE LUMINANCE DATA CD./SQ.M ANGLE (FOOTLAMBERTS) LUMINANCE 0 15276 ( 4458) 30 12027 ( 3510) 40 8046 ( 2348) 45 2626 ( 766) 50 2036 ( 594) 55 1297 ( 378) 60 428 ( 125) 65 28 ( 8) 70 25 ( 7) 75 21 ( 6) 80 23 ( 6) 85 27 ( 7) LIGHTING SCIENCES, INC. 7826 E. EVANS RD. SCOTTSDALE, AZ, USA 85260 CERTIFIED TEST REPORT No. 26993 RAB LIGHTING - LED OUTDOOR LUMINAIRE,CAT# HBLED10 WITH SPECULAR FLOOD REFLECTOR AND CLEAR FLAT GLASS LENS ONE LED ARRAY. LUMINAIRE OUTPUT = 338 LMS. LUMINAIRE OPERATING AT 120 VAC AND 13.3 WATTS COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE = .20 CC WALL 90 70 50 80 30 10 70 50 70 30 10 70 50 50 30 10 50 30 30 10 50 30 10 10 50 30 0 10 0 RCR 0 1.221.221.221.22 1.191.191.191.19 1.161.161.161.16 1.111.111.11 1.061.061.06 1.021.021.02 1.00 1 1.161.131.111.08 1.141.111.091.07 1.111.091.071.05 1.051.031.02 1.011.000.99 0.980.970.96 0.94 2 1.101.061.020.98 1.081.041.000.97 1.071.020.990.96 0.990.960.94 0.960.940.92 0.940.920.90 0.88 3 1.050.980.930.89 1.030.970.920.89 1.010.960.920.88 0.930.900.87 0.910.880.85 0.890.860.84 0.83 4 1.000.920.860.83 0.980.910.860.82 0.970.900.850.81 0.880.840.80 0.860.820.80 0.840.810.79 0.77 5 0.950.860.800.76 0.930.850.790.75 0.910.840.790.75 0.820.780.74 0.810.770.74 0.790.760.73 0.72 6 0.900.810.740.70 0.880.800.740.70 0.870.790.730.69 0.770.730.69 0.760.720.69 0.750.710.68 0.67 7 0.850.750.690.65 0.830.740.680.64 0.820.740.680.64 0.720.670.64 0.710.660.63 0.700.660.63 0.61 8 0.800.700.640.60 0.790.690.630.59 0.780.680.630.59 0.680.620.59 0.670.620.58 0.660.610.58 0.57 9 0.750.650.590.54 0.740.650.590.54 0.730.640.580.54 0.630.580.54 0.620.570.54 0.610.570.53 0.52 10 0.710.610.540.50 0.700.600.540.50 0.690.600.540.50 0.590.530.50 0.580.530.50 0.570.530.49 0.48 THE ABOVE COEFFICIENTS HAVE BEEN CALCULATED BASED ON LUMINAIRE LUMENS BECAUSE IN AN ABSOLUTE TEST THE BARE LAMP LUMENS ARE UNKNOWN. LIGHTING DESIGN CALCULATIONS MADE USING THESE COEFFICIENTS SHOULD THEREFORE USE THE LUMINAIRE LUMENS IN THE CALCULATION FORMULA LUMINAIRE INPUT WATTS 13.3 LABORATORY RESULTS MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST AND FIELD FACTORS HAVE NOT BEEN APPLIED. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE. LIGHTING SCIENCES, INC. 7826 E. EVANS RD. SCOTTSDALE, AZ, USA 85260 CERTIFIED TEST REPORT No. 26993 RAB LIGHTING - LED OUTDOOR LUMINAIRE,CAT# HBLED10 WITH SPECULAR FLOOD REFLECTOR AND CLEAR FLAT GLASS LENS ONE LED ARRAY. LUMINAIRE OUTPUT = 338 LMS. LUMINAIRE OPERATING AT 120 VAC AND 13.3 WATTS ELECTRICAL MEASUREMENTS INPUT VOLTAGE: INPUT CURRENT: INPUT POWER: POWER FACTOR: TOTAL HARMONIC DISTORTION: OFF STATE POWER: 120.0 0.190 13.3 58.3 76.93 0.00 VOLTS AC AMPS WATTS PERCENT PERCENT WATTS LIGHT OUTPUT LUMENS: EFFICACY: 338 25.4 lm lm/W SPECTRAL MEASUREMENTS X: y: u/u': v: v': Duv: CRI(Ra): 0.3210 0.3402 0.1994 0.3169 0.4754 0.0049 60.9 CRI(R9): CCT: RADIANT FLUX: -90.4 6021 979 K mW LIGHTING SCIENCES, INC. 7826 E. EVANS RD. SCOTTSDALE, AZ, USA 85260 CERTIFIED TEST REPORT No. 26993 RAB LIGHTING - LED OUTDOOR LUMINAIRE,CAT# HBLED10 WITH SPECULAR FLOOD REFLECTOR AND CLEAR FLAT GLASS LENS ONE LED ARRAY. LUMINAIRE OUTPUT = 338 LMS. LUMINAIRE OPERATING AT 120 VAC AND 13.3 WATTS LIGHTING SCIENCES, INC. 7826 E. EVANS RD. SCOTTSDALE, AZ, USA 85260 CERTIFIED TEST REPORT No. 26993 RAB LIGHTING - LED OUTDOOR LUMINAIRE,CAT# HBLED10 WITH SPECULAR FLOOD REFLECTOR AND CLEAR FLAT GLASS LENS ONE LED ARRAY. LUMINAIRE OUTPUT = 338 LMS. LUMINAIRE OPERATING AT 120 VAC AND 13.3 WATTS SIDE VIEW LUMINOUS OPENING LIGHTING SCIENCES, INC. 7826 E. EVANS RD. SCOTTSDALE, AZ, USA 85260 CERTIFIED TEST REPORT No. 26993 RAB LIGHTING - LED OUTDOOR LUMINAIRE,CAT# HBLED10 WITH SPECULAR FLOOD REFLECTOR AND CLEAR FLAT GLASS LENS ONE LED ARRAY. LUMINAIRE OUTPUT = 338 LMS. LUMINAIRE OPERATING AT 120 VAC AND 13.3 WATTS All testing was conducted in accordance with LM-79-08, Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products as published by the Illuminating Engineering Society of North America (IESNA). The condition of the item tested was new. exceeded 16 hours. Stabilization time before testing The test results (luminous distribution and flux) were obtained by using a Lighting Sciences series 6000 Type C Moving Mirror Goniophotometer • The photometric reference standard used is a set of three incandescent luminous intensity standard lamps calibrated and traceable to the U.S. National Institute of Standards and Technology. The test results (colorimetric and luminous flux) were obtained by using a Lighting Sciences model 4000 Integrating Sphere of either 1 or 2 meters diameter, having an internal reflectance exceeding 0.80. 4π geometry was used. Correction factors were applied for spectral mismatch and selfabsorption. The spectroradiometer employed was a LSC model 500E having a bandwidth of .84. • The photometric reference standard used is a set of three incandescent luminous flux standard lamps calibrated and traceable to the U.S. National Institute of Standards and Technology. • The colorimetric reference standard used is an incandescent spectral standard lamp calibrated and traceable to the U.S. National Institute of Standards and Technology. Power measurements were obtained with a Yokogawa WT210 power analyzer. Ambient temperature during testing was 25° C ± 1° C, measured using an Omega model DP460. Calibration certificates are on file at the laboratories of Lighting Sciences Inc.