FREQUENCY DIVIDER, PULSE DIVIDER type : DFL35 • Voltage or dry contact input • Division factor selectable from 2 up to 4096 • Isolated floating contact 200Hz max output frequency • Galvanic isolation • Application counter frequency adaptation, flow, speed, pulse distribution, signal shaping, signal level adaptation,... • AC or DC power supply. 5Vdc to 400Vac The frequency divider DFL35 lowers the frequency of a signal provide by counter, flow meter, or other pulse generator, and thus enable theirs acquisition by slower system. DESCRIPTION: Frequency divider (without pulse loss) made for pulse weight adaptation between pulse generator (flow meter, energy meter, …) and total counters. Division factor selectable by DIP switch (12 possibility) : /2 - /4 - /8 - /16 - /32 - /64 /128 - /256 - /512 - /1024 - /2048 - /4096. Special version with other factor on request. Input max frequency: 100 kHz Output max frequency: 250Hz Synoptic GENERAL CHARACTERISTIC: - LED showing the output contact state ( LED on = contact close) - tropicalization varnish, - protection class IP20 - input circuit protection, - galvanic isolation input / output, - DIN rail mounting, - wiring on screw terminal (2.5 mm² wire gauge) Output signal : (example with division factor of 2 and 4) Version and order code: • DFL35 : Selectable division factor (2 to 4096) (input: 24V typical, switching threshold: 10V) • DFL35/3 : Division factor fixed to 3 (input: 24 V typical, switching threshold: 10V) • Option -LV : Low voltage version (input: 5V typical, switching threshold: 2V) FREQUENCY DIVIDER E1 90 days accuracy (20 °C +/- 2 °C) DATASHEET DOWNLOADED ON WWW.LOREME.FR INPUT TYPE Voltage Switching threshold Impedance Contact POWER SUPPLY RANGE 0V / 24V nominal 0V / 5V for "LV" option 10V 2V for "LV" option > 50Kohms dry contact Internal 20Vdc polarization AUXILIARY Supply for input contact 20Vdc (filtering) OUTPUT Type Isolated Closed Contact Breaking voltage max Max current Breaking capacity Close time Open time Minimum output frequency Maximum output frequency TECHNICAL SPECIFICATIONS static relay 1500 Vac 250 VCA, 300 VCC 200 mA 30 VA < 1mS < 1mS 0Hz 250Hz (define at order) 230 Vac 50-60 Hz +/- 10 %, 2.3 VA 20 to 70 Vac-dc, 2 VA 80 to 265 Vac-dc, 2 VA 5 - 18Vdc or 9 - 30Vdc, 2 W Reverse polarity protected RECOMMENDED OPERATING CONDITIONS Operating temperature Storage temperature humidity Dielectric strength (input/supply/output) Protection Weight -10 °C to 60 °C -20 °C to +85 °C 85 % (not condensing) 1500 Vrms continuous IP20 210 g Electromagnetic compatibility Generic standards: NFEN50081-2 /NFEN50082-2 EN55011 EN61000-4-2 EN61000-4-4 EN61000-4-5 EN61000-4-8 EN61000-4-11 meet no influence < +/- 5 % < +/- 5 % no influence < +/- 5 % groupe 1 / classe A B EN61000-4-3 < +/- 5 % B EN61000-4-6 < +/- 10 % B A B DBT 2006/95/CE A A RACCORDEMENT ET ENCOMBREMENT: Division factor selected with internal DIP switch. (remove the right cover to access the DIP switch.) Be sure that the device is not powered before any operations. Note: only one switch should be ON E 2 LOREME 12, rue des Potiers d'Etain - 57071 Metz 03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Technique@Loreme.fr On account of the constant technologies and standards evolution, LOREME keeps the possibility to modify the specifications of the included products without notice.