HAZARDOUS AREA SOLUTIONS atex@atexdelvalle.com | www.atexdelvalle.com ATEX & IECEx air conditioning for electrical cabinets AIRATEX Ex Atex Zones 1, 2, 21 and 22 atex@atexdelvalle.com | www.atexdelvalle.com v. 1.0/16 2 Delvalle, wide experience in manufacturing solutions for hazardous area We put at your disposal wherever you go We offer over 40 years providing solutions to demanding customers who require very specific characteristics and behaviour according to the sector and their needs. Customize Totally your enclosure Our production systems can give custom-made solutions on demand. Every colour from RAL chart is available to be personalized. A variety of protection standards thanks to our own painting facilities. Contact us Confidentiality, reliability & quality www.atexdelvalle.com atex@atexdelvalle.com +34 945 601 381 +34 945 601 354 We are committed to working closely with our customers, providing them with exceptional service and offering an advanced and extensive range of products with very competitive prices. high standard of quality and services We only use materials provided by companies who offer the very highest quality, suitable and certified products. Our success is due to top quality assurance: ISO 9001, SGS, UL, TÜV, ISO 14000 and Ohsas 18001. ATEX , IECEx a nivel mundial. Please contact our technical sales department. A team of professionals with high experience and ability to solve all your queries. ALSO ONLINE Phone: Telf. +34 945 601 381 atex@atexdelvalle.com | www.atexdelvalle.com 3 Hazardous location air conditioners ATEX & IECEx AIRATEX Zones 1 and 2 Explosion-Proof Electrical Equipment for use in Hazardous (classified) Locations Zone 1 & 2 and designed for purged and non-purged enclosure systems, also Class I, Division 2, Groups B, C, and D for hazardous location applications. Certifications Atex & IECEX y UL. Zones 1 and 2. We offer high reliability ATEX Phone: +34 945 601 381 atex@atexdelvalle.com | www.atexdelvalle.com 4 Hazardous location air conditioners ATEX & IECEx AIRATEX Examples 8000V / 9500V Exemple 4500V / 6000V DESCRIPTION Includes process control systems for chemical, petrochemical, refining, field and offshore drilling operations. Delvalle hazardous location air conditioners are specifically designed and factory built to insure product integrity, reliability, and safety. Our entire line of ATEX and IECEx air conditioners are third party certified by UL/ DEMKO for ATEX/IECEx Zone 1 & 2. These units are designed specifically for hazardous environments for purged and non-purged enclosure systems and housed in a 316 stainless steel cabinet. Available in 1200W4,000 BTUH to 3000w 10,000 BTUH capacity. Typically, other manufacturers of Atex & IECEX enclosure cooling systems send their standard air conditioners to be converted for hazardous location applications. However, the companies that do the conversion may have to make changes that can affect the efficiency of the original unit. Often, components are substituted or added that may have an effect on the cooling capacity or useful life of the original system. Delvalle has available Air Conditioning for: - Class I, Division 2, Groups B,C & D - All the certificates UL listed MARKING Marking Atex: Ex II 2 G Ex d e ib IIB+H2 T4 Gb Marking IECEx: Ex d e ib IIB+H2 T4 Gb ADVANTAGES • Built in condensate evaporation package. • Easy pull-out filter. • Efficient, quiet and long lasting rotary compressor. • CFC-FREE refrigeration system. • Space saving aesthetic cabinet design. • 100% factory tested. • UL, ETL, and CSA Certified. Phone: +34 945 601 381 atex@atexdelvalle.com | www.atexdelvalle.com 5 Hazardous location air conditioners ATEX & IECEx AIRATEX TECHNICAL CHARACTERISTICS 1320W - 1800W REFERENCES AMPS Temp. Max. MAX ºF / ºC Weight (Ibs/Kg) 1320W 10.3 131/55c 300LBS(136KG) 1800W 11.1 131/55c 300LBS(136KG) REFERENCES Voltage BTUH MVOUT1320AEx 230V MVOUT1800AEx 230V Dimensions (In/mm) 49.465” (1256.41) H x 17.300” (439.42) W x 17.465” (443.6) D 49.465” (1256.41) H x 17.300” (439.42) W x 17.465” (443.6) D Need more information? Phone: +34 945 601 381 atex@atexdelvalle.com | www.atexdelvalle.com 6 Hazardous location air conditioners ATEX & IECEx AIRATEX TECHNICAL CHARACTERISTICS 2350W - 2800W AMPS Temp. Max. MAX ºF / ºC REFERENCES Voltage BTUH Weight (Ibs/Kg) MVOUT2350AEx 230V 2350W 14.1 131/55c 350LBS(158.8KG) MVOUT2800AEx 230V 2800W 13.6 131/55c 350LBS(158.8KG) Dimensions (In/mm) 54.090” (1373.89) H x 19.51” (495.55) W x 19.590” (497.59) D 54.090” (1373.89) H x 19.51” (495.55) W x 19.590” (497.59) D Need more information? Phone: +34 945 601 381 atex@atexdelvalle.com | www.atexdelvalle.com 7 Refrigerators American regulations UL Hazardous locations: Class 1 Division 2 Example We have a wide range of refrigerators with American standards UL hazardous locations: Class 1 Division 2: • Third party certified by UL, ETL, and CSA for Class 1 Division 2 areas. • Designed for purged and nonpurged enclosed systems. • Available in 2,000 to 27,000 BTUH Capacity. • Desgned for hazardous locations. Need more information? Phone: +34 945 601 381 atex@atexdelvalle.com | www.atexdelvalle.com 8 Refrigerator Atex VORTEX IP66 Zones 2 and 22 Tribex system Vortex Example FEATURES AND BENEFITS • Can be mounted on top or side of enclosure. • Small footprint fits on all enclosures. • Thermostatically controlled via mechanical thermostat. • Requires no wiring, can easily be installed in minutes. • No ambient, dirty, or humid air enters the enclosure. • Designed to cool environments quietly. • Significantly lower cost, compared to ATEX Certified air conditioners. • Contains no moving parts, resulting in very little required maintenance. The most economical Atex system to cool electrical panels ATEX & IECEX. ATEX VORTEX Enclosure Coolers are designed specifically for purged electrical enclosures in ATEX Zones 2 and 22, and Temperature Class T4 areas. The ATEX VORTEX incorporates the most up-to-date features into Vortex’s line of highly reliable, cost effective enclosure coolers. The Atex cooling system Vortex need a compressed air source always ready to act. • Reduce energy use. • 5 minute install. • Reduce noise levels. • 62 dBA operation, 78% quieter than typical vortex coolers. We offer high reliability ATEX Phone: +34 945 601 381 atex@atexdelvalle.com | www.atexdelvalle.com 9 Refrigerator Atex VORTEX IP66 Zones 2 and 22 TECHNICAL CHARACTERISTICS REFERENCES REFERENCES VORT900EXF VORT900EX VORT1500EXF VORT1500EX VORT2500EXF VORT2500EX VORT5000EXF VORT5000EX SPECIFICATIONS COOLING CAPACITY BTE/hr Watts 900 264 900 264 1500 440 1500 440 2500 733 2500 733 5000 1465 5000 1465 INCLUDES FILTER? THERMOSTAT Sí No Sí No Sí No Sí No Mechanic Mechanic Mechanic Mechanic Mechanic Mechanic Mechanic Mechanic Note: “F” is added to the reference if carried filter. Notes: Specifications are for 100 psig (6.9 bar) compressed air. Cold Air Ducting Kits and Cold Air Mufflers included. Use of a purge system is required. Purge system and spark arrestor are not included. Need more information? Phone: +34 945 601 381 atex@atexdelvalle.com | www.atexdelvalle.com 10 Refrigerator Atex VORTEX IP66 Zones 2 and 22 Luxorex system Vortex Example TECHNICAL DATA Pneumatic parameters - Protective gas supply: Instrument grade air. - Pressure requirement: 2....6,9 bar regulated. Ambient conditions - Ambient temperature: -20°C to 40°C. - Maintaining the temperature between: 26°C (80°F) and 35°C (95°F) through mechanical thermostat. - Inlet air max temperature: 49ºC. Mechanical specifications - Connection type: Pneumatic: 3/8” NPT (female). - Protection degree: IP66. Data for applications in Connection with Ex-areas - EC type examination certificate EC: EX II 3 GD T4. - ATEX certified for: Zones 2 and 22. - Temperature classification: T4 Class. Directive conformity - Directive 94/9/EC: EN13463-1:2009. Internal approvals - UL approval. - cULus. - Class I, Division 2, groups A, B, C and D. - Class II, Division 2, groups F and G; Clase III. The Atex cooling system Vortex need a compressed air source always ready to act. Phone: +34 945 601 381 atex@atexdelvalle.com | www.atexdelvalle.com 11 Hazardous area heater Ex ATEX DESCRIPCTION Compact convection heater for use in areas with explosion hazard for prevention of formation of condensation, temperature fluctuations and for protection against frost in transmitter housings, switch cabinets and measuring equipment. The resistance heater ensures an optimum operating temperature inside the electrical enclosure ADVANTAGES • Large convection surface • Maintenance free • Clip fixing • Ready for use Example references References RCEx050A RCEx050B RCEx100A RCEx100B TECHNICAL CHARACTERISTICS Approvals Heating Element Heater body Connection Connection PE Fixation Fitting position LCIE 01 ATEX 6073 X / 06 IECEx LCI 07.0020X CE 0081 High performance cartridge aluminium profile, silver anodised Si HF-JZ 3 x 0,75 mm2, 1m long cable 4 mm2 Mounting clip for 35mm DIN rail, EN 60715 Vertical airflow (connection on bottom) Storage temperature -45 to +70 °C (-49 to +158 °F) Protection type / Protection class IP6X / I (protection) Approval EAC in progress Phone: +34 945 601 381 atex@atexdelvalle.com | www.atexdelvalle.com 12 Hazardous area thermostat Ex Atex DESCRIPTION Compact small mechanical thermostat for temperature regulation and monitoring of heaters, for example in transmitter cabinets, control panels and measuring equipment which are deployed in areas with explosion hazard. The special switch construction enables high response accuracy, small switch temperature difference and a very long service life. High switching performance allows direct control of the heaters. ADVANTAGES • Compact design • Set temperature Example TECHNICAL CHARACTERISTICS references References THEx001 THEx002 Aluminio Ángulo de montaje Aprovals LCIE 01 ATEX 6074/04 IECEx LCI 07.0021 CE 0081 Connection Si HF - JZ 3 x 0,75 mm², 1 meter long Sensor element Contact type (1-pole) Thermostatic bimetal Mounting Mounting bracket with nut M8 (see illustration) Opens with rising temperature Service life > 100.000 cycles Max. switching capacity AC 250 V, 1,3 (0,65) A Max. inrush current AC 4 A - 12 seconds Casing Dimensions Weight Fitting position Storage temperature Protection type / Protection class Approval Aluminium, black anodised Longitud 110 mm Aprox. 0,2 kg Variable -45 to +70 °C (-49 to +158 °F) IP6X / I (protection) EAC in progress Phone: +34 945 601 381 atex@atexdelvalle.com | www.atexdelvalle.com 13 Contact us at: atex@atexdelvalle.com We’ll give a solution as DELVALLE OFFERS OTHER SOLUTIONS ATEX Atex enclosure Luxorex Serie Control equipment Contrex Serie Increased safety enclosure Tribex Serie Plug and socket boxes Serie Connex Atex terminal boxes Terbox Serie Pressurized enclosure Ex p Peppex Serie Phone: +34 945 601 381 atex@atexdelvalle.com | www.atexdelvalle.com 14 Contact us at: atex@atexdelvalle.com We’ll give a solution as DELVALLE OFFERS OTHER SOLUTIONS ATEX Atex junction box Geoex Serie Lighting LED Atex Luminex Serie Flameproof enclosure Atex Ex d Burj Serie Radios Atex Ex Walkies Talkies Workstations Pcex Serie Mobile systems Atex Ex Smartphones & Tablets Phone: +34 945 601 381 atex@atexdelvalle.com | www.atexdelvalle.com Flexible solutions Atex & IECEX Paso del Prao, 6. 01320 Oyón (Álava). Spain Telf. +34 945 601 381 www.atexdelvalle.com - atex@atexdelvalle.com Contact us, we will be available at any time.