ETL Compliance Report - January 2016

advertisement
3933 US Route 11
Cortland, NY. 13045
Telephone: 607-758-6291
Facsimile: 607-758-6661
www.intertek-etlsemko.com
January 18, 2016
Mathieu Malboeuf
Bramal
4 Rue du Transport
Coteau-Du-Lac, QC J0P 1B0
Intertek Test Report: 102265021CRT-002T
Dear Mr. Malboeuf,
Intertek has completed our testing of the Self-Ballasted LED Tube, Model T-10LED, to the indicated requirements of UL 1993
Issued: 2012/12/04 Ed:4 Self-Ballasted Lamps and Lamp Adapters, UL 8750 Issued: 2015/09/15 Ed:2 Light Emitting
Diode (LED) Equipment for Use in Lighting Products, CSA C22.2#1993 Issued: 2012/12/04 Ed: 2 Self-Ballasted Lamps
and Lamp Adapters, and CSA C22.2#250.13 Issued: 2014/07/01 Light Emitting Diode (LED) Equipment for Lighting
Applications. The test samples were received on August 12, 2015 in good condition. The evaluation was performed at Intertek,
th
th
Cortland, NY, from November 9 , 2015 through December 30 , 2015. The results of these tests are indicated as follows:
Standard
Clause
Test Completed
Pass / Fail
UL 1993
SA8.2
Input Measurements
Pass*
UL 1993
SA8.5
Temperature Test
Pass*
UL 1993
SA8.6
Dielectric Voltage-Withstand Test
Pass*
UL 1993
SA8.12
Tests for Dimmer Circuits
Pass
UL 1993
SA8.19
Risk of Electric Shock - Relamping
Pass
UL 1993
SA8.22
LED lamp and driver abnormal condition tests (Component Failure)
Pass
UL 1993
E.2.4
Insulation Resistance Test
Pass*
Note: See Test Report 102265021CRT-001T for details
The Self-Ballasted LED Bulb, Model Model T-10LED, was found to be in compliance with the indicated requirements UL 1993
Issued: 2012/12/04 Ed:4 Self-Ballasted Lamps and Lamp Adapters, UL 8750 Issued: 2015/09/15 Ed:2 Light Emitting
Diode (LED) Equipment for Use in Lighting Products, CSA C22.2#1993 Issued: 2012/12/04 Ed: 2 Self-Ballasted Lamps
and Lamp Adapters, and CSA C22.2#250.13 Issued: 2014/07/01 Light Emitting Diode (LED) Equipment for Lighting
Applications. This Test Report concludes the work anticipated for this phase of your project under Intertek quote number Qu00585635. See attached data for testing details. If there are any questions regarding this report please contact Justin Polhamus
at 607-758-6639, or Justin.polhamus@intertek.com.
Reported by
Reviewed by
Justin Polhamus
Project Engineer
Henriette Bullmer
Engineering Team Leader
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client
in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or
distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested
material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the
sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Intertek Testing Services NA, Inc.
3933 US Route 11, Cortland, NY 13045 USA
Telephone: +1 607-753-6711 Fax: +1 607-756-9891 Web: www.intertek-etlsemko.com
Intertek Test Data Sheets
Page 2 of 7
Test Data
Client:
Bramal
Engineer:
Justin Polhamus
Date: 1/18/2016
Job No.:
G102265021
Tested By:
Eric Youngs
Date: 1/18/2016
Report No.:
102265021CRT-002T
Reviewed By: Henriette Bullmer
Product:
Self-Ballasted LED Tube
UL 1993, 4th Ed, Issued 12/4/2012
Model No.:
T-10LED
UL 8750 2nd Ed Issued 9/15/15
CRT1508121020-001,
Sample Control Number(s): CRT1601121212-001
CSA C22.2#1993, 2
Standard(s):
Date: 1/18/2016
nd
Ed, Issued 12/4/2012
CSA C22.2 No 250.13 Issued 7/1/14
Contents
Page
Standard
Clause
Test Description
Pass/Fail
1
NA
NA
Report
NA
2
NA
NA
Tests to be Performed
NA
2
NA
NA
Sample Description
NA
3
NA
NA
Equipment used
NA
3
NA
NA
Sample Photos
NA
4
UL 1993
SA8.12
Tests for Dimmer Circuits
Pass
5
UL 1993
SA8.19
Pass
6-7
UL 1993
SA8.22
Risk of Electric Shock - Relamping
LED lamp and driver abnormal condition tests
(Component Failure)
Pass
Test sample numbers and descriptions
Sample #
Intertek Id
Description
Manufacturer
Model #
1
CRT1508121020-001
LED Tube
Bramal
T-10LED
CRT1601121212-001
LED Tube
Bramal
T-10LED
2
Test Equipment
#
Intertek Id
Description
Cal. Due
1
T1453
Humidity/Temperature Sensor
2/25/2016
2
A307
Data Logger
7/7/2016
3
T1312
Multiplex Card
7/7/2016
4
E463
Power Analyzer
4/1/2016
5
N1259
Timer
1/19/2016
6
O747
Dielectric/Ground Bond Tester
10/21/2016
7
V389
Leakage Current Tester
1/4/2017
Intertek Test Data Sheets
Page 3 of 7
Test Data
Client:
Bramal
Engineer:
Justin Polhamus
Date: 1/18/2016
Job No.:
G102265021
Tested By:
Eric Youngs
Date: 1/18/2016
Report No.:
102265021CRT-002T
Reviewed By: Henriette Bullmer
Product:
Self-Ballasted LED Tube
UL 1993, 4th Ed, Issued 12/4/2012
Model No.:
T-10LED
UL 8750 2nd Ed Issued 9/15/15
CRT1508121020-001,
Sample Control Number(s): CRT1601121212-001
CSA C22.2#1993, 2
Standard(s):
Date: 1/18/2016
nd
Ed, Issued 12/4/2012
CSA C22.2 No 250.13 Issued 7/1/14
Photo 1 - Self-Ballasted LED Tube, Model #T-10LED Driver View
Photo 2 - Self-Ballasted LED Tube, Model #T-10LED LED View
Intertek Test Data Sheets
Page 4 of 7
Test Data
Client:
Bramal
Engineer:
Justin Polhamus
Date: 1/18/2016
Job No.:
G102265021
Tested By:
Eric Youngs
Date: 1/18/2016
Report No.:
102265021CRT-002T
Reviewed By: Henriette Bullmer
Product:
Self-Ballasted LED Tube
UL 1993, 4th Ed, Issued 12/4/2012
Model No.:
T-10LED
UL 8750 2nd Ed Issued 9/15/15
Date: 1/18/2016
CSA C22.2#1993, 2
CRT1508121020-001,
Sample Control Number(s): CRT1601121212-001
Standard(s):
nd
Ed, Issued 12/4/2012
CSA C22.2 No 250.13 Issued 7/1/14
Tests of Dimmer Circuits: UL 1993 , Clause SA8.12
Test Parameters:
Test voltage
120 VAC, 60Hz, Half Wave Rectified Source and Adjustable Phase Cut Dimmer Supply
Test duration
7.5 Hours
Test Setup
Draped Loosely with Cheesecloth
Test Results: Phase Cut Dimmer Test; Test Duration: 7 Hours 30 Minutes
Sample
Voltage Supply (VAC)
Dimmer Type
1
120.0
Duration (h)
Phase Cut Dimmer
7.5
Test Results: Half Wave Rectified Supply Test; Test Duration: 7 Hours 30 Minutes
Sample
Voltage Supply (VAC)
Dimmer Type
Duration (h)
1
Half Wave Rectified
Supply
120.0
7.5
Results
No indications of
flame or
enclosure burn
through
Pass/Fail
Results
No indications of
flame or
enclosure burn
through
Pass/Fail
Pass
Pass
Dielectric Test Parameters:
Test duration
60 seconds.
Test Voltage
Two Times Rated Voltage + 1000V (2*347VAC + 1000VAC = 1694VAC)
Test Results:
Sample
Location of Measurement
Dielectric potential
(VAC)
Duration (s)
Results
Pass/Fail
1
Between live parts and metal foil surrounding
the nonmetallic enclosure
1700
60
No Breakdown
Pass
To Comply:
There shall be:
a) No flaming, glowing, or charring of the cheesecloth, or
b) No damage to the enclosure which would allow the articulated probe of Clause 9.6 to touch live parts
The device shall be capable of complying with the dielectric voltage-withstand test of Clause 8.6.
Intertek Comments:
X
The product complies with all applicable requirements of this test.
The product does not comply with the requirements of this test.
Test Date:
1/13/16 –
1/14/16
Tested By:
Environmental Conditions During Testing:
Equipment Used (See page 2 for details):
E. Youngs
Humidity:
1
52.2%
4
5
Pressure:
6
NA
Ambient:
24.7°C
Intertek Test Data Sheets
Page 5 of 7
Test Data
Client:
Bramal
Engineer:
Justin Polhamus
Date: 1/18/2016
Job No.:
G102265021
Tested By:
Eric Youngs
Date: 1/18/2016
Report No.:
102265021CRT-002T
Reviewed By: Henriette Bullmer
Product:
Self-Ballasted LED Tube
UL 1993, 4th Ed, Issued 12/4/2012
Model No.:
T-10LED
UL 8750 2nd Ed Issued 9/15/15
Date: 1/18/2016
CSA C22.2#1993, 2
CRT1508121020-001,
Sample Control Number(s): CRT1601121212-001
Standard(s):
nd
Ed, Issued 12/4/2012
CSA C22.2 No 250.13 Issued 7/1/14
Risk of Electric Shock - Relamping: UL 1993 , Clause SA8.19
Test Parameters:
Test voltage
Allowable Current
Test Circuit
120 VAC
5 M.I.U. (7.07 peak M.I.U.)
Per Figure 24.2 of UL 935
Test Results:
Sample
Test Voltage (VAC)
1
120.0
Measured Current
(M.I.U.)
0.241
Allowable Current (M.I.U.)
Pass/Fail
5
Pass
To Comply:
One end (lamp base) of the device under test shall be connected to its intended source of supply while the other end (lamp
base) of the device shall be considered accessible and shall be connected to the shock hazard measurement meter circuit and,
in turn, to earth ground as shown in Figure SA8.1. The current shall not exceed 5 M.I.U (7.07 peak M.I.U.).
Intertek Comments:
X
The product complies with all applicable requirements of this test.
The product does not comply with the requirements of this test.
Test Date:
1/15/2016
Tested By:
Environmental Conditions During Testing:
Equipment Used (See page 3 for details):
E. Youngs
Humidity:
1
19.6%
7
Pressure:
NA
Ambient:
24.4°C
Intertek Test Data Sheets
Page 6 of 7
Test Data
Client:
Bramal
Engineer:
Justin Polhamus
Date: 1/18/2016
Job No.:
G102265021
Tested By:
Eric Youngs
Date: 1/18/2016
Report No.:
102265021CRT-002T
Reviewed By: Henriette Bullmer
Product:
Self-Ballasted LED Tube
UL 1993, 4th Ed, Issued 12/4/2012
Model No.:
T-10LED
UL 8750 2nd Ed Issued 9/15/15
Date: 1/18/2016
CSA C22.2#1993, 2
CRT1508121020-001,
Sample Control Number(s): CRT1601121212-001
Standard(s):
nd
Ed, Issued 12/4/2012
CSA C22.2 No 250.13 Issued 7/1/14
LED lamp and driver abnormal condition tests: UL 1993, Clause 8.22 (Component Failure Test: UL 8750 Clause 8.7.2)
Test Parameters:
Test Voltage
Component tested
Test Setup
Run Time
120 VAC
Components with risk of shock or fire if failure occurs; Inductor T2, Capacitor C4
Mounted in enclosure and enclosure covered with white tissue paper and draped with a double
layer of cheese cloth
At Least 30 Minutes, until conditions are obviously stable
Test Results: Test Duration: 1 Hour 30 Mins
Sample
Testing Voltage
Condition
(VAC)
2
Short; Secondary
120
Pins
2
120
Short
Test Parameters:
Test duration
Test Voltage
Location
Test Results:
Sample
2
Component tested
Result
Pass/Fail
Inductor, T2
No Charring
Pass
Capacitor, C4
No Charring
Pass
60 seconds.
Two Times Maximum Operating Voltage + 1000V (2*347VAC + 1000VAC = 1694VAC)
Hot and Neutral conductors to dead metal
Location
Dielectric potential (VAC)
Between live parts and metal
foil surrounding the
1700
nonmetallic enclosure
Duration (s)
Pass/Fail
60
Pass
To Comply:
A luminaire shall withstand for a period of 1 minute, without breakdown, a test potential applied between live parts and
accessible non-current carrying parts.
Intertek Comments:
X
The product complies with all applicable requirements of this test.
The product does not comply with the requirements of this test.
Test Date:
1/15/2016
Tested By:
Environmental Conditions During Testing:
Equipment Used (See page 3 for details):
E. Youngs
Humidity:
1
26.6%
4
5
Pressure:
6
NA
Ambient:
24.4°C
Intertek Test Data Sheets
Page 7 of 7
Test Data
Client:
Bramal
Engineer:
Justin Polhamus
Date: 1/18/2016
Job No.:
G102265021
Tested By:
Eric Youngs
Date: 1/18/2016
Report No.:
102265021CRT-002T
Reviewed By: Henriette Bullmer
Product:
Self-Ballasted LED Tube
UL 1993, 4th Ed, Issued 12/4/2012
Model No.:
T-10LED
UL 8750 2nd Ed Issued 9/15/15
Date: 1/18/2016
CSA C22.2#1993, 2
CRT1508121020-001,
Sample Control Number(s): CRT1601121212-001
Standard(s):
nd
Ed, Issued 12/4/2012
CSA C22.2 No 250.13 Issued 7/1/14
LED lamp and driver abnormal condition tests: UL 1993, Clause 8.22 (Output Loading Test: UL 8750 Clause 8.7.3)
Test Parameters:
Test Voltage
Test Condition
Run Time
120 VAC
LED Driver Output Short Circuited
7 Hours
Test Results: 120VAC, 60Hz, 0.07A, 10.1W, Test Duration: 7 Hours
Measured Temperature Corrected Temperature
Sample
Components
( ºC)
to 25ºC (ºC)
1
Enclosure (Back Over Driver)
26.1
26.9
NA
Ambient
24.2
25.0
Allowed
Temperature (ºC)
90
NA
Pass / Fail
Pass
NA
To Comply:
The temperature on the enclosure shall not exceed 90°C.
Intertek Comments:
X
The product complies with all applicable requirements of this test.
The product does not comply with the requirements of this test.
Test Date:
1/15/2016
Tested By:
Environmental Conditions During Testing:
Equipment Used (See page 3 for details):
E. Youngs
Humidity:
1
38.7%
2
3
Pressure:
4
5
NA
Ambient:
24.4°C
Download