SolarCam_45174PL Ed.1_for pdf

advertisement
MA11 - Portable Alarm
Installation and Operating Instructions
These instructions should be retained in a safe place for future reference.
Kit Contents:
1 x Alarm Unit with belt clip
1 x Siren Plug
1 x Fixing Pack, (inc Wall Mounting
Clip, Webbing Strap, Belt Clasp)
1 x Instruction Leaflet
Tools and Equipment Required:
No.0 and No.1 Philips Screwdrivers
3 x 1.5V AAA ( LR03) Alkaline
Batteries
SAFETY
Always follow the manufacturers
advice when using power tools;
steps, ladders etc. and wear suitable
protective equipment (e.g. safety
goggles) when drilling holes etc.
Before drilling holes in walls, check
for hidden cables and pipes, the
use of a cable/pipe locater may be
advisable if in doubt.
The use of ear protection is advisable
when working in close proximity to
the Siren due to the high sound
level produced by this device.
All components are suitable for
mounting in dry interior locations
only.
INTRODUCTION
The Portable Alarm is a battery
powered multi-functional alarm.
The system has 2 operating
modes: ALARM and CHIME. The
Chime Mode is a low security
facility used to notify you when the
device is activated by producing a
door-chime sound. In alarm mode
the device will produce a constant
high volume alarm sound.
A dual Personal Attack function
enables the alarm to be activated at
any time in the event of a personal
threat or danger, (except in CHIME
mode when only the keypad will
trigger the Personal Attack Alarm).
Siren
Indicator
LED
Removing the Belt Clip:
The belt clip can be removed by
turning the screw slot to a vertical
position to release it from the
alarm body. Refitting is by the
reverse procedure.
Panic Alarm
Operating Cord
OPERATION
Sensitivity
Slide Switch
Siren Plug
(fits over Siren
Apperture)
Always ensure that batteries are
fitted and in good condition.
Wall/Door
Mounting
Bracket
DISAMED
Panic
Attack
INSTALLATION
Wall/Door Mounting:
CHIME ALARM
MODE MODE
Active
Active
Active
Vibration
Detector
Inactive
Active
Active
Entry/Exit
Delay
No
No
Yes
Siren
DoorChime
Siren
Alarm
Sound
The alarm can be mounted on a
wall or door using the mounting
bracket supplied. The mounting
bracket can be mounted in
position using the screws or
adhesive pads supplied. The
alarm then fixes to the mounting
bracket using the belt clip.
Note: In CHIME mode the cord
operated PA Attack feature will
only produce a chime sound and
not a full siren alarm.
Strap Mounting:
It is recommended that the User
Access code is always changed
form the default setting of 1 2 3 4 .
The webbing strap can be used to
attach the alarm to portable
objects, (e.g. bags cases etc) by
threading the strap behind and
through the slots in the belt clip.
This is easier if the belt clip is
removed from the alarm.
Changing User Access Code:
To change the code:
1) Press
,
to ensure the
alarm is disarmed.
2) Press
.
3) Enter the current access code,
the LED will flash once.
4) Enter a new 4 digit User Access
Code. The LED will flash once
to indicate that the new code
has been accepted.
Operating in the CHIME Mode:
To activate CHIME mode:
press
,
The alarm will produce a doorchime type sound each time the
vibration sensor is triggered or if
the Panic cord is removed from
the device.
Pressing the
and
buttons
together will trigger the Personal
Attack/Panic alarm and activate
the siren.
If activated, the alarm siren will
automatically stop after 60s and
the alarm will continue to operate
in CHIME mode. Alternatively the
siren can be stopped early and the
alarm returned to standby mode
by entering the 4 digit User
Access Code.
The LED indicator will start
flashing, the flashing will continue
until the 10s exit-delay expires, at
which point the Alarm will be
armed. If the vibration sensor is
triggered the LED indicator will
start flashing. This continues until
the entry-delay expires when the
siren will activate. The entry-delay
allows time for you to DISARM the
alarm before the siren activates.
If activated, the alarm siren will
automatically stop after 60s and
the alarm will continue to operate
in ALARM mode. Alternatively the
siren can be stopped early and
the alarm returned to standby
mode by entering the 4 digit User
Access Code.
Adjusting the sensitivity of the
Vibration Sensor:
The sensitivity of the vibration
sensor may be adjusted using the
slide switch on the side of the alarm.
Slider Position
UP
HIGH - smaller
amount of vibration
/movement required
to trigger sensor
DOWN
LOW - larger
amount of vibration
/movement required
to trigger sensor
Press
,
to exit CHIME
mode and retur n to standby.
Operating in the ALARM
Mode:
To activate ALARM mode:
press
,
Sensitivity
Changing the Entry Delay
Period:
TESTING
The ALARM mode entry-delay
period can be changed to 3, 6 or
12s. The entry-delay can only be
changed when the alarm is in
STANDBY.
With the alarm in STANDBY
mode:
a) Press
,
set the entry
delay period to 3s.
b) Press
,
set the entry
delay period to 6s.
c) Press
,
set the entry
delay period to 12s.
Personal Attack/Panic Alarm:
In the event of threat or danger
the alarm can immediately be
activated at any time (except in
CHIME mode) by either:
a) Pressing the
and
buttons together, or
b) Removing the pin from the
alarm by pulling the trigger
cord.
Note: In CHIME mode the Cord
operated PA Attack feature will
only produce a chime sound and
not a full siren alarm.
It is recommended that the alarm
is tested at regular intervals.
1) Remove the Panic Attack cord
to trigger the siren.
2) Enter the User Access Code to
stop the siren.
3) Press
,
CHIME mode.
to activate
4) Tap the alarm to trigger the
vibration sensor. The alarm will
produce the chime alert tone.
5) Press
,
to activate
ALARM mode and wait for the
exit-delay period to expire and
the LED to stop flashing.
6) Tap the alarm to trigger the
vibration sensor. the LED will
start flashing, after the entrydelay has expired the siren will
activate.
7) Enter the User Access Code to
stop the siren and return to
standby.
Note: A cloth can be used to
cover the siren and reduce the
sound output of the alarm
during testing.
MAINTENANCE
The product may be cleaned with
a soft damp cloth and then wiped
dry. Do not use abrasive, solvent
based or aerosol cleaners as this
may damage and/or discolour the
product. Do not allow water to
enter or attempt to clean inside
the unit.
Fitting and Replacing
Batteries:
Batteries:
2) The belt clip can be removed
by turning the screw slot to a
vertical position to release it for
the alarm.
Remove batteries before storing
the Alarm for extended periods. Do
not allow batteries to corrode and
leak as this may cause permanent
damage to the product.
Low Battery
Warning:
Indicator LED stays
ON after a key is
pressed
Replacement
Batteries:
3 x AAA (LR03)
Alkaline Batteries
Typical Life:
up to 1 year
Do not mix new and old batteries
or different types of batteries.
Do not fit rechargeable batteries.
At the end of their
useful life the batteries
should be disposed
of via a suitable
Recycling Centre. Do not dispose
of with your normal household
waste. DO NOT BURN.
1) To prevent the alarm activating
while changing or fitting the
batteries, press
,
to
switch the alarm into STANDBY
mode.
3) Remove battery cover fixing
screw and slide off battery
cover.
4) Fit 3 x 1.5V AAA (LR03) Alkaline
batteries observing the correct
polarity and fit into the battery
compartment.
5) Refit the battery cover and
replace the fixing screw and
belt clip (if required).
Note: When new batteries are
fitted the User Access Code will
reset to the default of 1 2 3 4
and will need changing to your
own code.
GUARANTEE
Novar ED&S undertakes to replace or repair at its discretion goods
(excluding non rechargeable batteries) should they become defective
within 2 years solely as a result of faulty materials and workmanship.
Understandably if the product has not been installed, operated or
maintained in accordance with the instructions, has not been used
appropriately or if any attempt has been made to rectify, dismantle or
alter the product in any way the guarantee will be invalidated.
The guarantee states Novar ED&S entire liability. It does not extend to
cover consequential loss or damage or installation costs arising from the
defective product. This guarantee does not in any way affect the
statutory or other rights of a consumer and applies to products installed
within the UK and Eire only.
If an item develops a fault within the first year, it should be returned to the
point of sale with:
1)
Proof of purchase.
2)
A full description of the fault.
3)
All relevant batteries (disconnected).
In the second year it should be returned direct to Friedland Technical
Sales Services Department at the address shown below.
Friedland is a trademark of Novar ED&S.
HELPLINE
If you have any problems with your
alarm, please call the Helpline on:
01268 563273
(Lines open 9.00am to 5.00pm, Monday to Friday)
Friedland, Novar Electrical Devices and Systems
The Arnold Centre, Paycocke Road, Basildon, Essex. SS14 3EA
www.friedlandsecurity.com
45383PL Ed.1
Download