Hydrel - Acuity Brands

advertisement
ARCHITECTURAL
FLOODLIGHTING
7000 FAMILY
7000 SERIES
7100 SERIES
7200 SERIES
THE HYDREL 7000 FAMILY
ARCHITECTURAL
LIGHTING SYSTEM
FLOODLIGHTS
The Hydrel
7000 Family
of floodlights
is comprised
of the
7000 Series,
7100 Series,
and
7200 Series.
1
CONTENTS
2-9
THE 7000 FAMILY / PERFORMANCE
10-17
7000 SERIES
18- 27
7100 SERIES
28-37
7200 SERIES
38- 41
PRODUCT APPLICATION GUIDE
42- 45
PROTECTED PERFORMANCE (CONSTRUCTION & FEATURES)
46- 47
MOUNTING OPTIONS / ACCESSORIES / DIMENSIONS - 7000 SERIES
48- 51
MOUNTING OPTIONS / ACCESSORIES / DIMENSIONS - 7100 SERIES
52- 57
MOUNTING OPTIONS / ACCESSORIES / DIMENSIONS - 7200 SERIES
58- 59
FINISH OPTIONS - STANDARD AND CUSTOM
60- 63
PRODUCT SPECIFICATIONS / ORDERING GUIDE
64
MOUNTING OPTION GUIDE
2
PRESENTING THE HYDREL
7000 FAMILY
AN ARCHITECTURAL LIGHTING SYSTEM
FOR THE 21st CENTURY
HIGH PERFORMANCE ILLUMINATION
for LONG LASTING SOLUTIONS
3
ARCHITECTURAL LIGHTING FOR THE 21st CENTURY
7000 Series
7100 Series
7200 Series
26Watts to 70Watts
50 Watts to175 Watts
250 Watts to1000 Watts
From Hydrel – the industry leader in sealed fixtures –
a family of rugged contemporary floodlights providing long lasting solutions for a
wide range of applications from 26 Watts fluorescent to1000 Watts HID.
The 7000 Series Luminaires
Compact, high performance fixtures
accommodate lamps to 70 Watt HID.
Numerous mounting possibilities are
available for both knuckle and yoke
fixtures, all achieved with a consistent
styling theme. Five optical systems
create a wide variety of vertical and
horizontal light distributions, from
tight spots to wide floods.
Page 10
The 7100 Series Luminaires
Mid-sized fixtures designed for lamps to
175 Watt HID set the industry standard for
performance. Available mounting
possibilities include knuckle, yoke, wall,
ceiling, and pole fixtures – all implemented
with a consistent styling theme. Seven
optical systems permit a wide variety of
vertical and horizontal light distributions,
from narrow spots to wide floods.
Page 18
The 7200 Series Luminaires
Large scale fixtures accommodate
lamps to1000 Watt HID. Multiple
mounting possibilities are available
for knuckle, yoke, wall, and pole
fixtures with a consistent styling
theme. Six optical systems allow
a wide variety of vertical and
horizontal light distributions, from
spots to wide floods.
Page 28
4
HIGH PERFORMANCE ILLUMINATION
Hydrel is an industry leader in three prime areas of high performance illumination:
BEAM CONTROL, GLARE CONTROL, and COLOR CONTROL
Performance Solves Problems. Hydrel provides the highest quality
Architectural and Landscape Floodlights. The optical performance
of the 7000 Family has the capability to solve many lighting
problems. Highest attention is paid to beam control, glare control,
and color control in the design of these fixtures.
Beam Control
Hydrel optical systems deliver excellent beam and distribution
control, offering numerous choices for architectural and
landscape applications. Reflector designs use hydroformed
and/or segmented aluminum elements with diffuse or specular
surfaces to produce precise distributions, including: spots,
horizontal spots, narrow horizontal spots, wide floods, vertical
floods, and horizontal flood distribution.
The 7000 Family accommodates a wide variety of light distributions
7000
SERIES
7100
SERIES
7200
SERIES
5 Floodlighting
Distributions
(see page 14)
7 Floodlighting
Distributions
(see pages 22-23)
6 Floodlighting
Distributions
(see pages 32-33)
5
A single 7100 Series 100 Watt
Metal Halide fixture with a
vertical flood distribution
illuminates this building. Vertical
flood distribution is excellent
for walls and buildings.
7200 Series 400 Watt Metal
Halide flood lights illuminate the
top of the Chrysler Building replica
at New York, New York Casino in
Las Vegas.
7200 Series
250 Watt Metal
Halide floodlights
illuminate the
area behind this
large statue at
Hollywood and
Highland in Los
Angeles.
7200 Series luminaires, employing
250 and 400 Watt Metal Halide lamps
uplight the Los Angeles City Hall.
Fixtures are located at the building
base, in the tower, and on the roof.
6
HIGH PERFORMANCE ILLUMINATION
Glare Control
Grid Louver (EGL)
External
Glare
Control
A flat black aluminum
grid mounted in the door
channel with set screws
reduces glare from various
viewing angles.
Barn Doors (BD)
Glare Shield (GS)
Each door is
independently mounted
with set screws in the
door channel. Use up to
four doors. Custom door
lengths available. Cuts
off upward glare at
35°,side glare at 50°
from beam center.
A formed aluminum
shield, mounted in
door channel by set
screws, cuts off
upward glare at 35°
from beam center.
35°
35°
50°
Dark Sky and Light Trespass
An increasingly important feature of optical
performance is glare control. Dark sky and light
trespass legislation are a concern for designers.
Hydrel offers external glare control for all of its
outdoor product lines including louvers, shields,
and barn doors. With the recent introduction of
new flood, ingrade, and accent fixtures, Hydrel has
introduced internal glare controls to eliminate the
inconveniences of external accessories. The
internal controls use source shields and baffles to
eliminate inefficient, unwanted light. Internal and
external glare controls are illustrated here.
A bank of 7200 Series
fixtures equipped with
400 Watt Metal Halide
lamps with narrow spot
distribution illuminates
a row of 100-foot-tall
palms at Morton’s in
Costa Mesa, California.
This temple is
beautifully
illuminated using
7100s with
Incandescent
sources and
wide flood
distribution
located inside
the structure.
Stowe Landscape
Gardens, National
Trust. "Temple of
Ancient Virtue"
Lighting by
Lightscape Projects
Ltd, London
Photo: Tim Soar
This sixty-foot-long sign is lighted by two 7100s with Horizontal Spot,
100 Watt Metal Halide sources. Located fifteen feet from the sign,
they provide excellent uniformity with minimum spill light. The internal
glare control minimizes glare to passers-by.
7
Internal Source Shields / Glare Control
Internal
Glare
Control
The 7000 Series features internal glare control
options for a number of distributions including spots,
horizontal floods, and horizontal spots. These shields
fasten internally, eliminating glare outside the desired
distribution pattern.
Internal source shields (ISS) eliminate the need for
external glare control devices such as half glare
shields and barn doors – providing clean,
architecturally pleasing surfaces.
without internal
source shield
with internal
source shield
Light distribution
with and without
Internal Source Shield
The tower and
colonnade at the
Bellagio Casino in
Las Vegas are
lighted by Hydrel
7200 Series 400
Watt Metal Halide
floodlights.
7100 Series spots with
Incandescent sources
beautifully illuminate this
memorial.
The mirror effect enhances
its beauty.
Stowe Landscape
Gardens, National
Trust. "Palladium
Bridge"
Lighting by
Lightscape Projects
Ltd, London
Photo: Tim Soar
Swashes of color highlight walls of this interior courtyard. 7100 Series
floodlights with 100 Watt colored Metal Halide lamps illuminate the Kaiser
Permanente Medical Center parking structure in Fontana, California.
8
HIGH PERFORMANCE ILLUMINATION
Color Control
Color is an important parameter for
lighting designers. Hydrel has been
at the forefront in providing split
glass and dichroic filters for a wide
range of projects. The illustrations
here show applications with the
7000 Family using filters and
colored lamps. Basic sources such
as Metal Halide, Incandescent,
Halogen, and High Pressure
Sodium produce their own distinct
spectra and resultant colors.
Color filtering can alter the basic
light source to produce desired
effects. One must also consider
the reflective characteristics of the
lighted surface and the perception
of the human eye as well as
ambient conditions. Dark colored
filters will result in some light loss
with heat generation. Dichroic
filters, which assist in heat transfer,
are commonly used for these
applications. Contact Hydrel for
assistance.
This wall screams excitement. Three 7100s use 100 Watt Metal Halide sources with
color filters to bring this building to life. Two units employ spot distributions and the
third uses a horizontal flood distribution. The 7100 provides an outdoor luminaire
with a theatrical effect.
A series of split glass filters on a test wall,
all fitted to a 7100 Series flood using varying
wattages depending on the color of filter
being tested. These and other filter colors
are available from Hydrel.
Medium Amber
Medium Green
Medium Blue
Magenta
Light Blue
Red
9
7100 Series spots and
vertical floods light this
building with and
without color filters.
The photos show the
same building with the
same lighting setup
except for the addition
of colored filters in the
photo to the right.
Hydrel recommends the use of mockups
to ensure that desired effects are attained.
Based on successful projects, a number of
filters and recommend sources have been
cataloged to simplify selection.
Below, two 100 Watt Metal Halide spots cast
a blue grazing beam on the left and a green
highlight on a distant tower.
This lobby is uplighted
with 100 Watt Mercury
Vapors and Metal Halides
using symmetrical
distributions.
10
7000 SERIES
ARCHITECTURAL
LIGHTING
SYSTEM
Lighting on the magical Eiffel Tower
replica at the Paris Casino in Las
Vegas includes over seven hundred
7000 Series fixtures.
11
7000 SERIES
7000 Series
7100 Series
7200 Series
26 Watts to70Watts
50 Watts to175 Watts
250 Watts to1000 Watts
Hydrel 7000 Series
Small Floodlights
This small, high
performance 7000 Series
flood light capitalizes on
Hydrel's proven reflector
and glare control designs
to provide performance
previously available only
in large fixtures.
113/4
298
5 3/4
146
6
153
A 7000 Series spot is
shown here on a yoke
mount. Its contemporary
styling will complement
any architectural
statement.
12
7000 SERIES
This compact fixture fulfills numerous architectural
and landscape applications. The 7000 Series
provides equivalent spot and fluorescent flood
performance in a housing only half the size of
larger fixtures.
Intelligent Design
Hydrel attends to details to assure the designer
that a quality product is placed on the job.
Owners can expect excellence and long product
life from the leader in the design of sealed fixtures.
The 7000 Family delivers protected performance.
Mounting
Versatility
A wide variety of
7000 Series
mounting options
are available.
Stanchion Tee
Mount shown
above, Yoke Mount
on Architectural
Junction Box
shown to right.
Protected Performance
Protection:
• Rugged die cast housings and doors
• Tough mountings
• Stainless steel fasteners
• Self-sealing silicone door gaskets
• Tempered glass lenses
• Textured powder coat finishes
Performance:
• High efficiency reflectors
• Variety of standard NEMA patterns
• Internal & external glare control
• Lockable aiming
• Wide dynamic range – 26Watt Fluorescent
to 70 Watt HID
• Low energy, efficient Fluorescent
to high intensity HID.
• High power factor magnetic and
electronic ballasts
• Ease of installation and maintenance
Performance
New efficient lamps and reflectors allow
designers to downsize to this small onequarter cubic foot flood light.
Construction
Critical sealing to prevent water
intrusion is accomplished with
Hydrel's proven “floating door”
design, in which the silicone
gasketed lens and door
assembly fasten to internal
bracketry ensuring even sealing
pressures.
7000 Knuckle Mount
on Architectural
Junction Box.
13
Compact
The 7000 Series is
slightly larger than
conventional
accent lights yet
provides significant
photometric
advantages –
increased
distributions,
uniformity, and
glare control.
7000 Series next to a typical accent light.
Up to 70 Watt
Metal Halide
spots with
internal glare
control.
Glare Control
Internal and external glare
control options are available
on all 7000 Series models.
Available with a wide range of accessories,
including Architectural Junction Boxes,
Stanchion Mounts, Tree Mounts, Wall
Mounts, and Pole Mounts.
Low Energy
42 Watt PLT Fluorescent
Floods – previously available
only in larger fixtures.
U.L. and C.U.L. Listed for
wet locations.
NEMKO CE N
IP 65 Rating
Hydrel is an ISO9001
Certified Manufacturer
14
BEAM CONTROL – 7000 SERIES
Five Floodlight Optical Systems
TSP Tight Spot
For applications requiring
a pattern with a tight,
concentric beam.
Optional Internal
Glare Control
Source Shield (ISS)
TSP
70W MH T6
50% Beam 13°x11°
Max Candel 48,042
20'
Beam shown: 70 Watt
Metal Halide lamp with
optional internal source
shield (ISS). Fixture
6 feet from test wall.
NHSP Narrow
Horizontal Spot
For applications requiring
a horizontal beam.
MFL Medium Flood
FL Flood
FL Fluorescent Flood
For applications requiring
a pattern with a wide,
concentric beam.
For applications requiring
a wide horizontal pattern.
For applications requiring a
wide horizontal pattern.
Standard Internal Linear
Spread Filter (LSF)
NHSP
70W MH T6
50% Beam 56°x15°
Max Candel 4,157
20'
Beam shown: 70 Watt
Metal Halide lamp with
standard linear spread
filter (LSF). Fixture 6 feet
from test wall.
MFL
70W MH T6
50% Beam 16°x13°
Max Candel 27,191
20'
Beam shown: 70 Watt
Metal Halide lamp. Fixture
6 feet from test wall.
FL
70W MH E17
50% Beam 73°x 99°
Max Candel 1,440
20'
Beam shown: 70 Watt
Metal Halide lamp. Fixture
6 feet from test wall.
FL
42W Fluor. TRT
50% Beam 78°x111°
Max Candel 571
20'
Beam shown: 42 Watt
Fluorescent lamp. Fixture
6 feet from test wall.
15
PERFORMANCE – 7000 SERIES
Architectural Detail
Below, 7000 Series illuminates
classic column and building
details with a 70 Watt Metal
Halide lamp in medium flood
distribution.
University Building
Left, big performance from a small
fixture – three 7000 Series fixtures
with 70 Watt Metal Halide lamps
illuminate a hall at Pomona College,
Claremont, California.
Sculpture
A 7000 Series fixture
with a 35 Watt Metal
Halide lamp in spot
distribution illuminates
a small sculpture.
Night Garden
Trees uplighted by a 7000
Series fixture with a 70 Watt
Metal Halide lamp in flood
distribution.
16
PERFORMANCE – 7000 SERIES
Large Tree Canopy
The 7000 Series is an
excellent choice for use in
the landscape. Its small
size and wide, dynamic
range of lighting options
allows designers to
create many effects.
Glare control capabilities
keep the light where it is
intended.
Column Detail
A 7000 Series 70 Watt
HID floodlight illuminates
ornate columns and eaves,
while a single 70 Watt HID
spotlight accents an
adjacent palm.
17
Public Art
This artistic piece is easily uplighted
with a 7000 Series fixture.
Small Sculpture
Polished stone sculpture
illuminated by a 7000
Series fixture with a
35 Watt Metal Halide in
flood distribution.
Nightscape
Two 7000 Series equipped
with 42 Watt Fluorescent lamps
highlight a low meandering
flowering hedge.
Paris Casino, Las Vegas
The Eiffel Tower replica at
this hotel is illuminated by
7000 Series High Pressure
Sodium 35 Watt fixtures
attached to tower beams.
18
7100 SERIES
ARCHITECTURAL LIGHTING SYSTEM
7100 Series floodlights with 100 Watt
filtered Metal Halide lamps illuminate the
Kaiser Permanente Medical Center
parking structure in Fontana, California.
19
7100 SERIES
7000 Series
7100 Series
26Watts to 70Watts
50Watts to175 Watts
7200 Series
250 Watts to1000 Watts
Hydrel 7100 Series
Medium Floodlights
These workhorse lights
provide rugged
watertight protection
with high performance
optical systems designed
to meet today’s
requirements for light
trespass, glare control,
and dark skies.
15 3/4
400
6 3 /4
6 3 /4
171
171
91/4
235
Contemporary styling to
complement any
architectural statement.
Shown here is a 7100
Series wide flood on a
yoke mount.
20
7100 SERIES
Mounting Versatility
This medium-size fixture, the workhorse of
the 7000 Family, offers a wide range of
mounting and glare control options to
facilitate its use in a variety of architectural
and landscape applications.
Intelligent design assures a quality product is
placed on the job. Owners can expect long
product life and superior performance from
the leader in the design of sealed fixtures. The
7000 Family delivers protected performance.
Protected Performance
Protection:
• Rugged die cast housings and doors
• Tough mountings
• Stainless steel fasteners
• Self-sealing silicone door gaskets
• Tempered glass lenses
• Textured powder coat finishes
Side mounted area light.
Performance:
• High efficiency reflectors
• Variety of standard NEMA patterns
• Internal & external glare control
• Lockable aiming
• Wide dynamic range – 50 Watt to 175 Watt HID
• Low energy, efficient, high intensity HID
• High power factor magnetic and electronic ballasts
• Easy installation and maintenance
A variety of stanchion and pole
mounts allows for single and
multiple fixture applications. Pole
Mount Tee shown.
Construction
Rugged yoke
mounted fixture on
an Architectural
Junction Box.
Knuckle mount makes a rugged,
sealed, compact design. Architectural
Junction Box provides a small, sealed
entryway for easy access.
21
Ceiling and side
mounts offer the
option of maintaining
architectural
consistency with
downlights.
The Internal Source Shield (ISS) eliminates
glare from intense flood lighting, providing
an unobtrusive source.
Wall Mount accessory (WMSA) with
integral splice access is available for up
or down lighting.
Glare Control
External glare shields are available in two
forms, the versatile barn doors (BD) above
or the simple half shield shown to right. The
barn doors can be used individually or as a
set and can be added easily in the field.
Yoke mount provides easy
aiming and adjustments
and a clean appearance.
The external half shield(GS)
is an easy field addition.
Distribution
U.L. and C.U.L. Listed for
wet locations.
NEMKO CE N
IP65 Rating
Hydrel is an ISO9001
Certified Manufacturer
A variety of NEMA distributions provides
the solution for most applications.
From Narrow Spots to Wide Floods, the
7100 Series covers a wide range of distribution.
Vertical Flood shown to right.
Internal glare controls are an option for spots,
horizontal spots, and horizontal floods. These
“soft” devices limit glare without altering the
clean external surface of the fixture.
22
BEAM CONTROL – 7100 SERIES
Seven Floodlight Optical System
NSP Narrow Spot
SP Spot
For applications requiring
a high intensity, narrow
beam of light.
For applications requiring
a pattern with a tight,
concentric beam of light.
Optional Internal
Glare Control
Source Shield (ISS)
NSP
150W MH T6
50% Beam 8°x 8°
Max Candel 101,550
20'
Beam shown: 150 Watt Metal
Halide lamp. Fixture 6 feet from
test wall. Shown with optional
Internal Source Shield (ISS).
NHSP Narrow
Horizontal Spot
HSP Horizontal Spot
For applications requiring
a high intensity, narrow
horizontal beam of light.
For applications requiring a
pattern with a tight,
concentrated, rectangular
beam of light.
Optional Internal
Glare Control
Source Shield (ISS)
Optional Internal
Glare Control
Source Shield (ISS)
Optional Internal
Glare Control
Source Shield (ISS)
SP
175W MH ED17
50% Beam 21°x15°
Max Candel 40,749
NHSP
175W MH ED17
50% Beam 82°x16°
Max Candel 14,680
HSP
175W MH ED17
50% Beam 81°x 49°
Max Candel 6,383
20'
Beam shown: 175 Watt Metal
Halide lamp. Fixture 6 feet from
test wall. Shown with optional
Internal Source Shield (ISS).
20'
20'
Beam shown: 175 Watt Metal
Halide lamp. Fixture 6 feet from
test wall. Shown with optional
Internal Source Shield (ISS).
Beam shown: 175 Watt Metal
Halide lamp. Fixture 6 feet from
test wall. Shown with optional
Internal Source Shield (ISS).
23
VFL Vertical Flood
HFL Horizontal Flood
WFL Wide Flood
For applications requiring a
vertical, rectangular pattern.
For applications requiring a
wide, horizontal pattern.
For applications requiring
a beam with a wide,
concentric pattern.
Optional Internal
Glare Control
Source Shield (ISS)
VFL
175W MH ED17
50% Beam 84°x 84°
Max Candel 5,016
20'
Beam shown: 175 Watt Metal
Halide lamp. Fixture 6 feet
from test wall.
HFL
175W MH ED17
50% Beam 114°x 37°
Max Candel 7,600
20'
Beam shown: 175 Watt Metal
Halide lamp. Fixture 6 feet from
test wall. Shown with optional
Internal Source Shield (ISS).
WFL
175W MH ED17
50% Beam 30°x 23°
Max Candel 20,812
20'
Beam shown: 175 Watt Metal
Halide lamp. Fixture 6 feet
from test wall.
24
PERFORMANCE – 7100 SERIES
Facade Detail
The 7000 Series
(35 Watt HPS) is used
to illuminate the facade
of the Paris Hotel in
Las Vegas, Nevada.
Contemporary High Rise
Frost Bank Building in
Austin, Texas is beautifully
illuminated by 7100s with
Metal Halide sources in
spot and horizontal flood
distributions.
Turn-of-the
Century Structure
Hydrel 7100 Series
flood lights
illuminate the clock
tower building at
Sun Microsystems
headquarters in
Palo Alto,
California.
25
Directional Sign
A 100 Watt Metal Halide source
with a horizontal flood distribution
in a 7100 Series fitted with an
external glare shield highlights a
small directional sign
Public Sculpture
A low wattage Metal
Halide lamp in vertical
flood distribution set
back four feet accents
this tall, intricate
sculpture.
Horizontal Cast Concrete Sign
This sixty-foot-long sign is lighted
by two 7100s with horizontal
spot, 100 Watt Metal Halide
sources. Located fifteen feet
from the sign, they provide
excellent uniformity with
minimum spill light. The internal
glare control minimizes glare to
passers by.
Aspen Grove
These Aspen trees
are illuminated by a
7100 with a Metal
Halide source, wide
flood distribution – a
beautiful winter
scene.
26
PERFORMANCE – 7100 SERIES
Small Sign
Single 7100 Series 100 Watt Metal
Halide fixtures are popular for
lighting small signs.
Large Trees
This beautiful deciduous
tree changing colors is
accented by a 7100 with a
vertical flood, 100 Watt
Metal Halide source, set
back twenty feet.
Dense Foliage
This setting features a 7100, 100 Watt Metal Halide
with horizontal flood distribution beneath the tree
and a similar fixture with vertical flood distribution
in the foreground.
27
Hollywood Landmark
Several 7200 Series Metal Halide spots
uplight a large statue at Hollywood and
Highland in Los Angeles, California.
28
7200 SERIES
ARCHITECTURAL LIGHTING SYSTEM
The spectacular
726-foot-high
Hoover Dam is
illuminated by Hydrel
7200 Series Metal
Halide flood fixtures.
29
7200 SERIES
7000 Series
26Watts to 70Watts
7100 Series
7200 Series
50 Watts to175 Watts
250 Watts to1000 Watts
Hydrel 7200 Series
Large Floodlights
Designed for big applications –
puts light where you need it
with a variety of beam patterns
and multiple mounting options
as well as internal glare control
options for smooth cutoff.
23 3/8
594
10 3/8
264
14 7/16
367
23
584
Contemporary styling to complement any
architectural statement.
Shown here is a 7200 Series horizontal spot
on a knuckle mount.
30
7200 SERIES
Large floodlights for big lighting jobs. The 7200’s
wide range of mounting and glare control
options facilitate its use in a variety of large scale
architectural and landscape applications.
Intelligent design assures a quality product is
placed on the job. Owners and designers can
expect long product life and superior quality from
Hydrel, leader in the design of sealed fixtures.
The 7000 Family delivers protected performance.
Construction
The 7200 Series displays a clean, architectural shape
compatible with a variety of architectural styles.
Protected Performance
Protection:
• Rugged die cast housings and door
• Tough mountings
• Stainless steel fasteners
• Self-sealing silicone door gaskets
• Tempered glass lenses
• Textured powder coat finishes
Performance:
• High efficiency reflectors
• Variety of standard NEMA patterns
• Internal & external glare control
• Lockable aiming
• Wide dynamic range – 250 Watt to 1000 Watt HID
• Low energy, efficient, high performance HID
• High power factor, CWA and SCWA magnetic ballasts
• Ease of installation and maintenance
The rugged 7200 Series knuckle has an integral junction
box for a protected wireway. Versatile mountings allow
protection, easy aiming, and access.
Narrow Horizontal Spot with
Internal Source Shield.
U.L. and C.U.L. Listed for
wet locations.
NEMKO CE N
IP 65 Rating
Hydrel is an ISO9001
Certified Manufacturer
31
Custom Performance
The 7200 Series includes several
unique fixtures for a variety of
lighting applications.
Surface Mounted Ballasts, unique to the
7200 Series fixtures, accommodate
lamps to1000 Watts HID.
Shown here are a wall and base mount.
A variety of extensions is available for
special mountings.
Glare Control
External glare shields are offered in two
styles. The simple half shield and the versatile
barn doors. The barn doors (BD) can be used
individually or as a set. These glare shields
(GS) are easily added in the field.
As shown, a 7200 yoke mount with a half
glare shield in a spot distribution.
Internal glare controls may be specified as
an option for spots, horizontal spots, and
horizontal and vertical floods. These “soft”
devices limit glare without altering the clean
external surface of the fixture
Yoke mounts offer easy aiming
and adjustment in addition to
a clean appearance. The Internal
Source Shield (ISS) eliminates
glare from intense spot lights
providing an unobtrusive source.
Horizontal flood with
Internal Source
Shield (ISS).
32
BEAM CONTROL – 7200 SERIES
Six Floodlight Optical Systems
SP Spot
For large applications requiring
a pattern with a tight concentric
beam of light.
NHSP Narrow Horizontal
Spot
HSP Horizontal Spot
A more concentrated
version of the horizontal spot for
smaller applications.
For applications requiring a
pattern with a tight,
concentrated rectangular
beam of light.
Optional Internal
Glare Control
Source Shield (ISS)
Optional Internal
Glare Control
Source Shield (ISS)
Optional Internal
Glare Control
Source Shield (ISS)
SP
400W MH ED37
50% Beam 8°x 8°
Max Candel 366,871
NHSP
400W MH ED37
50% Beam 71°x17°
Max Candel 30,694
HSP
400W MH ED37
50% Beam 78°x 41°
Max Candel 15,521
20'
Beam shown: 400 Watt Metal
Halide lamp. Fixture 8 feet from
test wall. Shown with optional
Internal Source Shield (ISS).
20'
Beam shown: 400 Watt Metal
Halide lamp. Fixture 8 feet from test
wall. Shown with optional Internal
Source Shield (ISS).
20'
Beam shown: 400 Watt Metal
Halide lamp. Fixture 8 feet from
test wall. Shown with optional
Internal Source Shield (ISS).
33
VFL Vertical Flood
HFL Horizontal Flood
WFL Wide Flood
For applications requiring a
vertical, rectangular
pattern.
For applications requiring a
wide horizontal pattern.
For applications requiring a
pattern with a wide concentric
beam.
Optional
Internal Glare
Control
Source Shield (ISS)
Optional
Internal Glare
Control
Source Shield (ISS)
VFL
400W MH ED37
50% Beam 84°x 57°
Max Candel 10,366
HFL
400W MH ED37
50% Beam 126°x 37°
Max Candel 12,768
20'
Beam shown: 400 Watt Metal
Halide lamp. Fixture 8 feet from
test wall. Shown with optional
Internal Source Shield (ISS).
20'
Beam shown: 400 Watt Metal
Halide lamp. Fixture 8 feet from
test wall. Shown with optional
Internal Source Shield (ISS).
WFL
400W MH ED37
50% Beam 50°x 73°
Max Candel 17,299
20'
Beam shown: 400 Watt Metal
Halide lamp. Fixture 8 feet from
test wall.
34
PERFORMANCE – 7200 SERIES
Large Architectural Complex
A bank of 1000 Watt 7200 Series flood /spot lights
illuminate the Cinerama Dome in Hollywood, California.
35
Monumental Public Works
This spectacular shot of Hoover
Dam shows the uniformity
achieved by a bank of 1000 Watt
7200 Series Metal Halide fixtures
using flood and spot distributions.
Industrial Security
This 7200 Series Metal
Halide flood lights the
parking lot at a distribution
center in Los Angeles,
California.
Picture above shows a 400 watt 7200
Series with flood distribution.
At left a row of 1000 Watt 7200 Series
flood and spot lights at Hoover Dam.
Note rear extension for spot distribution.
36
PERFORMANCE – 7200 SERIES
Wall Wash
These 7200 Series
Metal Halide, 250 Watt
floods uplight the walls
of the New York, New
York Casino in Las
Vegas. Half glare
shields are used in
several key locations.
Highlight
A 7200 Series using a 250 Watt
filtered Metal Halide lamp accents the
roof on an ice skating rink in Anaheim,
California.
Tall Palms
Morton’s Restaurant,
Costa Mesa, California.
A row of 100-foot-tall
palms is illuminated by a
bank of 7200 Series fixtures
equipped with 400 Watt,
Metal Halide lamps with
spot distribution.
37
Large Sculpture
These 7200 Series,
400 Watt, Metal Halide
fixtures uplight a large
statue at Hollywood
and Highland in Los
Angeles, California.
Theme Structure
These 7200 Series, 400 Watt,
Metal Halide fixtures uplight the
base of a large statue at
Hollywood and Highland in Los
Angeles, California.
Large Scale
Commercial
A bank of eight 7200
Series 1000 Watt spots,
seen here to the
immediate left mounted
on a rooftop, shine
across the Hollywood
and Highland complex
to accent the theme
wall seen in photo
below.
38
APPLICATION INFORMATION
Signs
Wattage Distribution Setback Size
Small Low Level Horizontal Signs
The 7000 family of Architectural Floodlights economizes
installation. Advanced photometrics deliver higher
lighting levels for your energy dollar.
42TRT
70M
175M
250M
FL
HSP
HSP
HSP
3'
4'
6'
8'
4' X 6'
6' X 10'
8' X 12'
16' X 24'
Small Low Level Vertical Signs
Trees
70M
100M
175M
250M
Open Structure
10'-20'
MH enhances green 35-50FL
MV enhances blue
50-75FL
HPS enhances brown 35-50FL
20'- 40'
50-70FL
75-100FL
50-70FL
40'-60'
70-175FL
100-250FL
70-150FL
60'- 80'
175-400FL
250-400FL
250-400FL
10'- 20'
20'- 40'
40'-60'
3'
4'
5'
6'
6' X 3'
10' X 5'
15' X 10'
20' X 10'
Large Horizontal Signs
Tight Structure
MH enhances green 35-50SP
MV enhances blue
75-100SP
HPS enhances brown 35-50SP
FL
VFL
VFL
VFL
60'- 80'
80'+
50-100SP 70-175SP 175-400SP 1000SP
100-175SP 175-250SP 400SP
50-70SP
70-150SP 250-400SP 1000SP
100M
175M
250M
400M
5'
10'
10'
15'
10' X 20'
20' X 30'
10' X 15'
20' X 30'
4'
6'
8'
10'
10' X 5'
15' X 10'
20' X 15'
30' X 15'
Large Vertical Signs
100M
175M
250M
400M
✔
✐✇
HSP
HSP
HSP
HSP
VFL
VFL
VFL
VFL
✓✐✇
✒✐✇
VFL
✑✐✇
VFL
SP
SP
SP
SP
WFL
VFL
FL
FL
FL
FL
HSP
FL
Shown here:
FL Flood
HFL Horizontal Flood
HSP Horizontal Spot
MFL Medium Flood
VFL Vertical flood
WFL Wide Flood
SP Spot
39
Flags
Walls and Buildings Uplighting
For flag sizes 5' to 10' in width
Required wattage for pole height & number of fixtures
For light colored, smooth concrete walls
Pole Ht.
15'
25'
40'
50'
60'
80'
100'
150'
200'
Distribution
SP
SP,NSP
SP
SP
SP
SP
SP
SP
SP
Wattage
single
fixture
35M
50-70M
70-100M
150-175M
175-250M
400-1000M
400-1000M
400-1000M
1000M
Wattage
two
fixtures
35M
50-70M
70-100M
150-175M
175-250M
250-400M
250-400M
400-1000M
400-1000M
Wattage
three
fixtures
35M
50-70M
70-100M
150-175M
175-250M
250M
250M
400M
400-1000M
Wall height
Wattage
Distribution
Spacing
Setback
10'
35-70
FL, VFL
10'
3'
20'
50-100
VFL
10'
4'
30'
175
WFL
10'
5'
40'
250
WFL
20'
10'
50'
250
WFL
20'
10'
Required setback from base for pole height and number of fixtures
Single
fixture
2'- 3'
2'- 3'
Pole Ht.
15' to 50'
50' to 200'
2 fixtures
180° apart
1/5 of pole ht.
1/10 of pole ht.
3 fixtures
120° apart
1/5 of pole ht.
1/12 of pole ht.
Columns (Uplighting 1'- 3' in diameter)
For light colored, smooth concrete columns
Column ht.
Wattage
Distribution
Setback
10'
35-70
SP
1'
20'
50-100
SP
1'-2'
30'
70-175
SP
2'
40'
150-250
SP
2'
HFL
50'
175-250
SP
2'-3'
60'
250-400
SP
2'-3'
HFL HFL
HFL
WFL
VFL
VFL
MFL
MFL
SP
60'
400
WFL
20'
10'
40
APPLICATION INFORMATION
Signs
Wattage Distribution Setback Size
Small Low Level Horizontal Signs
The 7000 family of Architectural Floodlights economizes
installation. Advanced photometrics deliver higher
lighting levels for your energy dollar.
42TRT
70M
175M
250M
FL
HSP
HSP
HSP
3'
4'
6'
8'
4' X 6'
6' X 10'
8' X 12'
16' X 24'
Small Low Level Vertical Signs
Trees
70M
100M
175M
250M
Open Structure
10'-20'
MH enhances green 35-50FL
MV enhances blue
50-75FL
HPS enhances brown 35-50FL
20'- 40'
50-70FL
75-100FL
50-70FL
40'-60'
70-175FL
100-250FL
70-150FL
60'- 80'
175-400FL
250-400FL
250-400FL
10'- 20'
20'- 40'
40'-60'
60'- 80'
3'
4'
5'
6'
6' X 3'
10' X 5'
15' X 10'
20' X 10'
Large Horizontal Signs
Tight Structure
MH enhances green 35-50SP
MV enhances blue
75-100SP
HPS enhances brown 35-50SP
FL
VFL
VFL
VFL
80'+
50-100SP 70-175SP 175-400SP 1000SP
100-175SP 175-250SP 400SP
50-70SP
70-150SP 250-400SP 1000SP
100M
175M
250M
400M
HSP
HSP
HSP
HSP
5'
10'
10'
15'
10' X 20'
20' X 30'
10' X 15'
20' X 30'
4'
6'
8'
10'
10' X 5'
15' X 10'
20' X 15'
30' X 15'
Large Vertical Signs
100M
175M
250M
400M
VFL
VFL
VFL
VFL
WFL
160'
140'
WFL
120'
100'
VFL
SP
SP
80
60
40
20
SP
SP
VFL
SP
NSP
NSP
NSP
NSP
Shown here:
HFL Horizontal Flood
HSP Horizontal Spot
SP Spot
VFL Vertical flood
NSP Narrow Spot
WFL Wide Flood
WFL
41
Flags
Walls and Buildings Uplighting
For flag sizes 5' to 10' in width
Required wattage for pole height & number of fixtures
For light colored, smooth concrete walls
Pole Ht.
15'
25'
40'
50'
60'
80'
100'
150'
200'
Distribution
SP
SP,NSP
SP
SP
SP
SP
SP
SP
SP
Wattage
single
fixture
35M
50-70M
70-100M
150-175M
175-250M
400-1000M
400-1000M
400-1000M
1000M
Wattage
two
fixtures
35M
50-70M
70-100M
150-175M
175-250M
250-400M
250-400M
400-1000M
400-1000M
Wattage
three
fixtures
35M
50-70M
70-100M
150-175M
175-250M
250M
250M
400M
400-1000M
Wall height
Wattage
Distribution
Spacing
Setback
10'
35-70
FL, VFL
10'
3'
20'
50-100
VFL
10'
4'
30'
175
WFL
10'
5'
40'
250
WFL
20'
10'
50'
250
WFL
20'
10'
Required setback from base for pole height and number of fixtures
Single
fixture
2'- 3'
2'- 3'
Pole Ht.
15' to 50'
50' to 200'
2 fixtures
180° apart
1/5 of pole ht.
1/10 of pole ht.
3 fixtures
120° apart
1/5 of pole ht.
1/12 of pole ht.
Columns (Uplighting 1'- 3' in diameter)
For light colored, smooth concrete columns
Column ht.
Wattage
Distribution
Setback
10'
35-70
SP
1'
20'
50-100
SP
1'-2'
30'
70-175
SP
2'
40'
150-250
SP
2'
50'
175-250
SP
2'-3'
60'
250-400
SP
2'-3'
VFL
WFL
HSP
HFL
HFL
HFL
HFL
60'
400
WFL
20'
10'
42
PROTECTED PERFORMANCE
Stainless steel door
retention fasteners
are floating and
replaceable. Selfcentering door
makes a reliable,
repeatable seal.
Rugged knuckle uses
machine tool technology to
handle weight, providing
180° vertical tilt adjustment,
and 360° rotation to put
light where it is needed.
A single tamper-proof
fastener secures knuckle in
position. Angle indicator
marks are provided. (See
photo on page 44.)
Corrosion
resistant steel
brackets facilitate
easy mounting
for reflectors and
door retention.
Ballast wiring and
mounting hardware
easily accessible for
replacement. Wiring
harness is covered by
a protective plate.
High power magnetic factor ballasts mounted to
housing allow maximum heat dissipation, long life,
and reliable lamp starting.
Quick wire disconnects
ensure easy reflector
installation or removal.
Remote enclosures with slide tray mounted ballasts
on 1000 Watt lights help reduce component
temperature while easing maintenance.
Hydrel Flood Lighting
Providing Solutions with Protected Performance|
The primary function of a lighting fixture body is providing
protection for electrical and optical components within.
Hydrel, a long time leader in sealed lighting designs, brings
its experience and expertise to flood lighting, using heavy
die cast components, unique lens sealing methods, and
protected wiring.
43
Long lasting
silicone gaskets
protect against
water and insects.
Tempered glass lens is
permanently bracketed
and gasketed to the
door to prevent
moisture penetration.
Heavy duty die cast aluminum
door with integral channels for
gasketing and accessory retention.
The wide lip provides a guide for
self centering and positive sealing.
The inside of the door is indexed
for repeatable positioning of
internal glare shields on the door.
Internal glare shield eliminates
glare outside the desired light
distribution pattern.
Stainless steel captive door
fasteners are provided. Door
screw grommet/casting design
allows for positive sealing while
preventing damage to the
grommet through overtightening.
U.L. and C.U.L. Listed for
wet locations.
NEMKO CE N
IP 65 Rating
Hydrel is an ISO9001
Certified Manufacturer
Heavy Duty Knuckle Design
The 7000 Series knuckle design, based on heavy duty machine tool technology,
features a self releasing taper, allowing infinite vertical adjustment through180°
while under heavy load. Rotational range is 360°.
Left: Standard knuckle
design for the 7000 and
7100 Series fixtures.
Right: Heavy duty 7200
Series knuckle configuration
with integral junction box.
360° rotation and
180° vertical adjustment
with infinite locking
positions.
44
PROTECTED PERFORMANCE
The 7000 Family delivers protected performance. The Intelligent Design process recognizes that a primary
function of a lighting fixture is to provide protection for its electrical and optical components. Hydrel, a long
time leader in underwater lighting brings that experience to floodlighting with heavy die cast components,
unique lens sealing methods, and protected wiring. Intelligent design assures a quality product is placed on
the job. Owners and designers can expect long product life and high quality from Hydrel, the leader in the
design of sealed lighting fixtures.
Performance:
Protection:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
High efficiency reflectors
Variety of standard NEMA patterns
Internal & external glare control
Lockable aiming
Wide dynamic range – 26Watt Fluorescent to 1000 Watt HID
Low energy, efficient Fluorescent to high intensity HID
High power factor magnetic and electronic ballasts
Ease of installation and maintenance
Rugged die cast housings and door
Tough mountings
Stainless steel fasteners
Self-sealing silicone door gaskets
Tempered glass lenses
Textured powder coat finishes
Color Filters
Hydrel remains at the forefront in providing
segmented glass and dichroic filters suitable for
a wide range of projects.
Indexing
Indexing scale on inside of door allows for
precise positioning of internal glare shields or
other devices. Positioning is not disturbed by
relamping or other maintenance.
Segmented glass filter mounted in a
7100 Series door. Filters attach to the
door via the accessory mounting
track. Filters can be mounted in
conjunction with a glare shield.
An array of color filter
options are available to
enhance lighting
applications
Heavy Duty Knuckle
The 7000 Series knuckle design, based on heavy
duty machine tool technology, features a selfreleasing taper, allowing infinite vertical
adjustment through 180° while under heavy
load. Rotational range is 360°. A single tamperproof fastener secures knuckle in position.
Angle indicator pointer is provided; note the
raised dot angle indicator marks at 15° intervals.
45
Single Tool Convenience
Captive, tamper-proof fasteners retain
doors, junction box covers, and
knuckles. One common wrench
provides maintenance personnel
access and aiming ability.
U.L. and C.U.L. Listed for
wet locations.
NEMKO CE N
IP 65 Rating
Hydrel is an ISO9001
Certified Manufacturer
Spring Retention
Relamping and maintenance are facilitated
by door retention, captured screws, and
simple bracketry. Knuckle and yoke mount
fixtures use a spring retention system
which easily adapts for a variety of
mounting options.
Visit the Hydrel Website: www.hydrel.com
Visit our website for specification sheets, installation
instructions, and a comprehensive selection of
photometric data for the products in this catalog, as well
as for other Hydrel products.
Flood lights
Area lights
Ingrade lights
Accent lights
Underwater lights
Go to www.hydrel.com.– select “floodlights” to supplement
the information in this catalog with specification sheets,
installation instructions, and photometric data for all models
of the 7000 Series of floodlights.
Border lights
Accessories
Custom lights
46
WMSA
Wall Mount
Knuckle /Yoke
7000 SERIES – MOUNTING
Mounting Options
KM
Knuckle Mount
YM
Yoke Mount
EWM
Extended Wall Mount
Knuckle / Yoke
Mounting Accessories
ARJB
Architectural Junction Box
Knuckle /Yoke
PSSA
Pedestal Stanchion Mount
Knuckle /Yoke
TRJB
Tree Mount
Knuckle /Yoke
FJB
Flush Mount Junction Box
Knuckle /Yoke
SMT
Stanchion Mount Tee
Knuckle /Yoke
PMT
Pole Mount Tee
Knuckle /Yoke
SMSA
Stanchion Mount
Knuckle /Yoke
PAR / PAS
Pole Arm Round
Pole Arm Square
Knuckle / Yoke
PMSA
Pole Mount
Knuckle /Yoke
(Shown on pole)
7000 SERIES – DIMENSIONS
Mounting Options
PATR / PATS
Pole Arm Twin Round
Pole Arm Twin Square
Knuckle / Yoke
(in inches/millimeters)
Mounting Accessories
61/2
3 3/4
18
298
298
EWM 457
Extended Wall Mount
5 3/4
146
6
6
8 1/4
12 - 18 - 24
610
61/2
3 5/8
165
92
PAR4/PAS4
Pole Arm Round
Pole Arm Square
6
15 2
5 1/2
18
457
140
13 7/ 8
353
KM
Knuckle Mount
7
6
178
457
6
PSSA
Pedestal
Stanchion
Mount
23/8
/8
60
113/4
6
SMSA18
Stanchion Mount
1
153
BD
Barn
Doors
6
153
70
21/4
25
6
GS
Glare
Shield
57
7
6
6
178
152
152
92
23/4
31/4
83
298
3 5/8
6
15 2
SMT
Stanchion Tee Mount
15 2
113/4
298
12 - 18 - 24
304 - 457 - 608
PATR4/PATS4
Pole Arm Twin Round
Pole Arm Twin Square
Accessories
60
89
18
15 2
23/8
3 1/2
152
YM
Yoke Mount
89
24
89
95
15 2
15 2
31/2
3 1/2
304 - 457 - 608
6
210
6
152
6
15 2
153
140
127
11 3/4
113/4
5 1/2
5
165
3 3/4
95
41/5
31/4
107
83
41/8
6
152
105
41/8
105
WMSA
Wall Mount
TRJB
Tree Mount
PMSA
Pole Mount
FJB
Flush Mount
Junction Box
ARJB
Architectural
Junction Box
47
Mounting Options
Accessories
KM - Knuckle Mount The 7000
Series Knuckle provides a heavy
duty, self-releasing, machine tool
taper allowing a continuous,
lockable vertical adjustment
through 180°. Rotation range is
360°.
YM - Yoke Mount Heavy duty
aluminum yoke is attached to body
with stainless steel bolts and
polymeric finish caps. Fixtures are
supplied with 10 feet of 18-3
STW(U.S. Standard) cord for supply
connection.
ISS - Internal Source Shield
Fastens to reflector mounting plate
eliminating glare beyond the
desired light distribution pattern.
Mounting Accessories
SMT - Stanchion Mount Tee
PMT- Pole Mount Tee
These units include a tee for
mounting two fixtures. 24"
(610mm) length is standard.
GS - Glare Shield The formed
aluminum shield, mounted in the
door channel with set screws, cuts
off upward glare at 35° from beam
center.
SMSA18 - Single.
Stanchion Mount.
This cast aluminum.unit
includes a.base plate
for surface mounting.
Splice access is
provided. Available in
a variety of lengths,
consult ordering guide.
PSSA - Pedestal.
Stanchion Mount
Cast aluminum.unit is fitted
with a.base plate for
surface mounting. Splice
access is provided.
WMSA - Wall Mount
Consists of three pieces:
a mounting plate, the
fixture mounting
bracket, and a splice
access plate. Unit
mounts over a recessed
wall box installation.
PMSA - Pole Mount, This unit
is a slipfitter for a standard
2 3/8" O.D. x 4" Tenon. Used for
pole top mounting the fixture.
ARJB - Architectural
Junction Box Two
conduit openings on
bottom and one fixture
mounting hole on top.
Two tamper-resistant
captive screws secure
splice access cover.
BD - Barn Doors Provide
adjustable glare shielding. Each
door independently mounts with
set screws.
PAR-Pole Arm Round
PAS- Pole Arm Square
Pole Mounted Arm,12,18,or 24
inches long, for existing round or
square pole applications. PATR and
PATS Tee Mount Arms are also
available.
48
7100 SERIES – MOUNTING
Mounting Options
KM
Knuckle Mount
YM
Yoke Mount
WUS
Wall Mount, Side
Up
WMS
Wall Mount, Side
Down
FJB
Flush Mount Junction Box
Knuckle /Yoke
TRJB
Tree Mount
Knuckle /Yoke
Mounting Accessories
PSSA
Pedestal Stanchion Mount
Knuckle / Yoke
PMSA
Pole Mount
Knuckle / Yoke
ARJB
Architectural Junction Box
Knuckle / Yoke
WMSA
Wall Mount
Knuckle /Yoke
SMSA
Stanchion
Mount
Knuckle / Yoke
PMT
Pole Mount Tee
Knuckle / Yoke
EWM
Extended
Wall Mount
Knuckle / Yoke
SMT
Stanchion Mount Tee
Knuckle / Yoke
PAR / PAS
Pole Arm Round
Pole Arm Square
Knuckle / Yoke
PATR / PATS
Pole Arm Twin Round
Pole Arm Twin Square
Knuckle / Yoke
49
7100 DIMENSIONS
(in inches/millimeters)
Mounting Accessories
Mounting Options
15 3/4
400
15 3/4
400
23/4
3 3/4
70
95
6 3 /4
6 3 /4
1
41/5
31/4
171
83
107
6
41/8
25
171
91/4
152
41/8
131/4
337
235
6
105
152
105
FJB
Flush Mount
Junction Box
ARJB
Architectural
Junction Box
181/2
WMSA
Wall Mount
470
KM
Knuckle Mount
YM
Yoke Mount
31/4
83
21/4
57
61/2
5
165
127
WMS
Wall Mount
Side
Down
131/4
337
131/4
18
3 3/4
457
95
EWM
Extended Wall Mount
7
6
178
152
PMSA
Pole Mount
31/2
337
6
89
24
TRJB
Tree Mount
15 2
610
5
6
61/2
127
15 2
165
4
102
4
102
18
18
457
457
5
127
41/4
108
6
6
15 2
15 2
WUS
Wall Mount
Side
Up
131/4
337
SMSA18
Stanchion Mount
SMT
Stanchion Mount Tee
6
15 2
6
15 2
31/ 2
24
89
610
4 3/16
7
6 1/ 2
15 3/4
10 6
178
165
400
2
51
6
15 2
4 3/16
PMT
Pole Mount Tee
106
71/4
CM
Ceiling Mount
PSSA
Pedestal
Stanchion Mount
184
5 1/2
140
6
3 1/2
152
89
Accessories
4
4
13/4
102
102
45
12 - 18 - 24
304 - 457 - 608
15 3/4
15 3/4
15 3/4
400
400
400
3 5/8
92
PAR4/PAS4
Pole Arm Round
Pole Arm Square
5 1/2
140
6
3 1/2
152
9 3/4
9 3/4
9 3/4
235
235
235
89
12 - 18 - 24
304 - 457 - 608
BD
Barn Doors
GS
Glare Shield
LC
Polycarbonate Cover
PATR4/PATS4
Pole Arm Twin Round
Pole Arm Twin Square
3 5/8
92
50
7100 SERIES – MOUNTING
Mounting Options
KM - Knuckle Mount
The 7100
Knuckle
The
7100Series
Series
employs aprovides
heavy duty,
knuckle
a
self-releasing
heavy
duty,machine
self
tool taper allowing
a
releasing
machine
continuous,
lockable a
tool
taper allowing
vertical adjustment
continuous
lockable
through 180°.
Rotation
vertical
adjustment
range is 360°.
through
180°.
Rotation range is
360°.
YM - Yoke Mount
A heavy duty aluminum
yoke attaches to unit body
by stainless steel bolts with
polymeric finish caps, lock
washers and nuts. Fixtures
are provided with 10 feet of
18-3 STW (U.S. Standard)
cord for supply connection.
WMS/WUS - Fixed Wall
Mount The 7100 Series
Wall Mount includes a
mounting plate and a
factory installed splice box
which hooks into the
mounting plate for easy
installation. It is secured
by set screws and an
access plate is provided
on the underside.
CM - Ceiling Mount
A mounting splice
box is attached to
the unit. The fixture
is secured with set
screws,
Mounting Accessories
ARJB - Architectural
Junction Box
Two conduit
openings on bottom
and one fixture
mounting hole on
top. Two tamperresistant captive
screws secure splice
access cover.
PSSA - Pedestal Stanchion Mount
Two conduit openings on bottom
and one fixture mounting hole on
top. Two tamper-resistant captive
screws secure splice access cover.
WMSA - Wall Mount
Consists of three
pieces: a mounting
plate; the fixture
mounting bracket;
and a splice access
plate. This unit
mounts over a
recessed wall box
and provides a clean
installation.
PMSA - Pole Mount,
This unit is a slipfitter
for a standard 2 3/8"
O.D.x 4" Tenon. Used
for pole top
mounting of the
fixture.
SMSA - Single Stanchion Mount
Two conduit openings on bottom
and one fixture mounting hole on
top. Two tamper-resistant captive
screws secure splice access cover.
51
Accessories
Mounting Accessories
PAR- Pole Arm Round
PAS- Pole Arm Square
Pole Mounted Arm,12,18,or 24 inches long, for
existing round or square pole applications. PATR and
PATS Tee Mount (Twin) Arms are also available.
GS - Glare Shield
Formed aluminum shield is mounted in
the door channel with set screws and cuts
off upward glare at 35° from beam center.
PMT - Pole Mount Tee
Similar to the PM Pole Mount
with a tee for mounting two
fixtures. 24"(610mm) length
is standard.
SMT - Stanchion Mount Tee
Similar to the SMSA, this unit
provides a tee for mounting
two fixtures. Standard length
is 24" (610mm).
BD - Barn Doors
Provide adjustable glare shielding. Each
door mounts independently with set screws.
TRJB - Tree Mount This unit consists of
a round splice box similar in construction
to the WMSA wall mount with mounting
ears. It is held to the tree by a one-inch
band and turnbuckle provided by others.
LC - Polycarbonate Cover
This clear polycarbonate cover protects the
lens from vandalism. Fitted in the door
channel, affixed with set screws.
52
7200 SERIES – MOUNTING
Mounting Options (250 Watt & 400 Watt products)
KM
Knuckle Mount
YM
Yoke Mount
Mounting Accessories (250 Watt & 400 Watt products)
TNM
Tenon Mount
Knuckle
SMSA
Stanchion Mount
Knuckle / Yoke
EWM
Extended Wall Mount
Knuckle / Yoke
PMT
Pole Mount Tee
Knuckle / Yoke
PATR / PATS
Pole Arm Twin Round
Pole Arm Twin Square
Knuckle / Yoke
PAR / PAS
Pole Arm Round
Pole Arm Square
Knuckle / Yoke
53
Mounting Options (1000 Watt product requires SMB)
KM
Knuckle Mount
YM
Yoke Mount
Mounting Accessories (1000 Watt SMB products)
SMB
Surface Mount Box
Knuckle / Yoke
Mounting Accessories (1000 Watt SMB products)
SMBEWM
Extended
Wall Mount
Knuckle / Yoke
SMBR
Remote Ballast
(Can be used for a
wide variety of
mounting situations.)
SMBSMSA
Stanchion Mount
Knuckle / Yoke
SMBTNM
Tenon Mount
Knuckle / Yoke
SMBPMT
Pole Mount Tee
Knuckle / Yoke
SMBSMT
Stanchion Mount Tee
Knuckle / Yoke
54
Mounting Options (all 7200 Series products)
7200 SERIES
DIMENSIONS
23 3/8
23 3/8
594
594
KM
Knuckle Mount
(in inches/millimeters)
YM
Yoke Mount
10 3/8
10 3/8
264
Mounting Accessories
264
(250 Watt & 400 Watt products)
5
14 7/16
14 7/16
126
367
367
23
101/2
584
61/2
267
TNM
Tenon Mount
165
6
15 2
6
152
6
15 2
6
152
4
Accessories
102
22
22 13 /16
5 3 /8
580
137
16 3/4
2 5/8
425
67
18
559
457
252
14
10
354
113/8
289
6
6
152
15 2
SMSA18
Stanchion Mount
Knuckle
SMSA18
Stanchion Mount
Yoke
EGL External Grid Louver
BD Barn Door
2213 /16
4
580
102
53 /8
580
137
10
14
4
252
354
10 2
22 13 /16
3 3/8
86
GS Glare Shield
LC Lexan Cover
3 3/4
36
PMT
914
Pole Mount Tee
Knuckle
95
3 3/8
Mounting Accessories (1000 Watt SMB products)
86
SMBEWM
Extended
Wall Mount
Knuckle / Yoke
3 3/4
36
PMT
914
Pole Mount Tee
Yoke
95
4
271/2
698
102
61/2
165
101/2
267
241/4
616
3 3/4
95
EWM
Extended Wall Mount
Knuckle
6 1/2
6 1/2
165
165
61/2
165
241/4
9 1/2
181/4
241
464
9 1/2
181/4
241
464
3 3/4
616
EWM
Extended Wall Mount
Yoke
95
5 1/2
140
6
3 1/2
152
89
12 - 18 - 24
304 - 457 - 608
PAR4/PAS4
Pole Arm Round
Pole Arm Square
3 5/8
92
5 1/2
140
6 1/2
6 1/2
165
6
165
3 1/2
152
89
12 - 18 - 24
PATR4/PATS4 304 - 457 - 608
Pole Arm Twin Round
Pole Arm Twin Square
SMBTNM
Tenon Mount
Knuckle / Yoke
3 5/8
92
19
483
8 3/16
208
19
483
8 3/16
208
55
Mounting Accessories (1000 Watt SMB products) continued
19
483
SMBR
Remote mount
6 1/2
8 3/16
165
208
6 1/2
165
8 3/16
(Can be used for a
wide variety of
mounting
placements.)
208
19
483
8 3/16
19
6 1/2
165
208
483
SMB
Knuckle
SMB
Yoke
6 1/2
165
6 1/2
165
22
559
SMBSMT
Stanchion Tee Mount
Knuckle / Yoke
22
559
6
6
15 2
15 2
38
965
8 3/16
38
208
965
9 1/2
9 1/2
241
241
9 1/2
9 1/2
241
241
8 3/16
38
208
965
SMBPMT
Pole Tee Mount
Knuckle / Yoke
SMBSMSA
Stanchion Mount
Knuckle / Yoke
6 1/2
6 1/2
165
165
311/4
794
311/4
794
6 1/2
165
8 3/16
38
208
965
56
7200 SERIES – MOUNTING
Mounting Options
YM - Yoke Mount
A heavy duty
aluminum yoke
attaches to body
with stainless steel
bolts with polymeric
finish caps, lock
washers and nuts.
Fixtures are
equipped with 10
feet of 16-3 STW
(U.S. Standard) cord
for supply
connection.
KM - Knuckle Mount
The 7200 Knuckle
includes an integral
junction box and uses
a rugged machine
tool taper to lock
adjustments between
0°and 180°. Rotation
adjustment of 360°.
Mounting Accessories
EWM - Extended
Wall Mount / Yoke
Accepts 7200 yoke
version for wall
applications.
TNM - Tenon Mount/Knuckle
Mounts in various orientations
to receive standard 7200
knuckle mount.
PMT - Pole Mount Tee/Yoke Accepts two
7200 yoke mounts. 36” (914mm) length is
standard, custom lengths are available.
PMT - Pole Mount Tee /Knuckle
Accepts two 7200 knuckle mounts.
EWM - Extended Wall
Mount / Knuckle
Accommodates standard
7200 knuckle mount for
wall applications.
SMSA - Stanchion Mount
This cast aluminum unit is provided
with a base plate for surface mounting.
Splice access plate is provided. Also
available for yoke mount.
PAR- Pole Arm Round
PAS - Pole Arm Square
Pole Mounted Arm,12,18,or 24
inches long, for existing round or
square pole applications. PATR
and PATS Tee Mount (Twin) Arms
are also available.
57
Mounting Accessories (1000 Watt SMB product)
Accessories
BD - Barn Doors
Provide glare
shielding. Each
door independently
mounted by set
screws. Available in
custom lengths.
One to four doors
can be used.
SMBPMT - Pole Tee Mount, Knuckle Accommodates
two standard 7200 knuckle mounts with ballasts mounted
in the extruded aluminum tee (1000 Watt units).
SMBPMT - Pole Tee Mount, Yoke Similar to the knuckle
SMBPMT above but accepts two 7200 1000 Watt yoke mounts.
SMB - Mount, Knuckle
Accommodates the 7200
knuckle mount with ballast
mounted in the extrusion
(1000 Watts). Also available
for yoke mount.
SMBSMSA - Stanchion
Mount Extruded
aluminum with splice
access plate and base
plate which can be
custom drilled. Accepts
the 7200 knuckle mount
with ballast located in the
extrusion (1000 Watts).
Also available for yoke
mount.
SMBEWM - Extended Wall
Mount, Knuckle Accommodates
7200 knuckle mount, ballast is
located in the extrusion (1000
Watts). Also available for yoke
mount.
GS - Glare Shield
Formed aluminum
shield mounted in
the door channel
with set screws
cuts off upward
glare at 35° from
beam center.
EGL - External
Grid Louver
Door channel
mounted, flat
black aluminum
grid cuts off glare
from various
viewing angles.
LC - Polycarbonate
Cover
Clear polycarbonate
cover protects the
lens from vandalism.
Fits in the door
channel, affixed with
set screws.
58
FINISH OPTIONS – STANDARD
Each of the ten standard finish colors is available in
its own distinctive surface texture. The particular
texture associated with a particular color is
indicated in these photos.
Custom finishes are available. Textures of custom
finishes are dependent on the finish material
specified. Please consult Hydrel.
DDB Dark Bronze
Colors shown here are
approximate, and only
accurate up to the limits
of the four-color printing
process.
DNA Natural Aluminum
Aluminum fixture surfaces
are four step pre-treated
prior to being painted with
a long-lasting TGIC
polyester powder coat.
BZ Bronze
SND Sand
BL Black
STG Steel Gray
WH White
GN Green
GR Gray
TVG Terra Verde Green
59
FINISH OPTIONS – CUSTOM
Custom finishes
are always an
option at Hydrel
Fixtures and
accessories can be
finished to your
specifications. Consult
Hydrel for details and
ordering information.
60
SPECIFICATIONS / ORDERING GUIDE – 7000 SERIES
Description
The 7000 Series Flood Light is a compact, high
performance outdoor fixture accommodating lamps to
70 Watt HID. This unit is designed to provide consistent
styling within Hydrel’s floodlighting systems.With a
variety of distributions and mounting options, the 7000
greatly extends the uniform lighting capabilities of lower
level floodlights.This fixture is fully sealed and suitable
for wet locations.
Features & Specifications
MATERIAL: Die cast aluminum housing and door.
LENS: Flat tempered glass.
LAMP:
Incandescent: T-4, Mini-can to 100 Watts.
Fluorescent: TRT Triple Tube lamps to 42 Watts.
HID: T-6, G12 to 70 Watts, E-17 medium base to 70 Watts;
Elliptical, E-27 to 80 Watts.
SOCKET:
Incandescent: Mini-can screw base.
Fluorescent: 4-Pin, GX24Q base. HID: G-12, medium, or
E27 base pulse-rated 4KV.
LENS: Flat tempered glass.
MOUNTING: See ordering guide below, Mounting Options and
Accessories on page 46, and Mounting Option chart on page 64
for comprehensive list of mounting capabilities.
Knuckle Mount: Die cast aluminum with 1/2" NPT galvanized
nipple.
Yoke Mount: Aluminum with10' of 18-3 STW flexible cord for US
standard, 3m of 3GX1.0mm HO7RN-F cable for European
standard. Polymer yoke mount caps are black finish.
GLARE CONTROL: Internal glare control elements. External,
adjustable barn doors or fixed glare shields available.
ELECTRICAL COMPONENTS: Integrally mounted ballasts rated
for low temperatures. Fixtures are 100% factory tested.
FINISH: See ordering guide for colors.
FASTENERS: Stainless Steel.
LISTING: U.L., C.U.L., CE, NEMKO.
WEIGHT: 20 lbs.
VOLTAGE: See ordering guide below.
EPA: 0.64
LIGHT DISTRIBUTIONS: See ordering guide below.
NOTE: All lamps must be rated for "Universal Burning Position"
because fixture tilt changes lamp orientation.
REFLECTORS: High purity anodized specular, semispecular, or patterned lighting sheet in various
configurations designed to provide maximum
performance and uniformity.
Model
Wattage & Lamp
U.S.
7000
EUROPEAN
Incandescent
100Q1 T4
MC
NA
Fluorescent
26TRT GX24Q-3
32TRT GX24Q-3
42TRT GX24Q-4
GX24Q-3
GX24Q-3
GX24Q-4
Metal Halide
50M
ED17
70M
ED17
35CMT6 T6
70CMT6 T6
70CM ED17
med.
med.
G12
G12
med.
NA
Ellip.
T6
T6
Ellip.
HPS
35S 1
50S
70S
E17
E17
E17
med. NA
med. E27
med. Ellip. E27
MV
50H
75H
80H
E17
E17
NA
med. E27
med. NA
Ellip. E27
E27
G12
G12
E27
Voltage
Distribution
Mounting
U.S. EUROPEAN
120 22050HZ
208 23050HZ
220 24050HZ
240
277
347
120/277
TB
MVOLT 11
TSP 2
NHSP 2
MFL 2
FL 3
KM Knuckle Mount ARJB 4
FJB 4
YM Yoke Mount
PSSA
Tight Spot
Nar. Hor.Spot
Med. Flood
Flood
Mounting Acc.
SMSA–––5
TRJB
WMSA
PMSA
1
2
3
4
5
Available in 120V only
Available with T6 & T4 lamps only
Available with E17 & TRT lamps only
See individual spec sheet for conduit options
Available in 6" increments from 12" to 48",
specify length
6 Two fixtures per mounting
7 Available in 6" increments from 12" to 24",
specify length
8 Available with TSP & MFL dist. only
9 Available with FL dist. only
10 Not available with NHSP
11 MVOLT is the standard voltage
for fluorescent lamps
12 Options mutually exclusive
PMT 6
SMT 6
EWM –––5
PAR4/–––7
PAR5/–––7
PAR6/–––7
PAS4/–––7
PAS5/–––7
PAS6/–––7
PATR4/–––6,7
PART5/–––6,7
PART6/–––6,7
PAST4/–––6,7
PAST5/–––6,7
PAST6/–––6,7
Accessories
Lamp
Arch. J-Box
LPI Lamp
Internal
Included
Flush Mt. J-Box
ISS 8
Int. Source Shield
Ped. Stan. Mt.
9
IHL
Int. Honey Comb
Splice Access
10
Stanchion Mount CFAMB Color Filter Amber
Splice Access
CFRED 10 Color Filter Red
Tree Mt. J-Box
CFBLU 10 Color Filter Blue
Wall Mount
CFGRN 10 Color Filter Green
Splice Access
External 12
Pole Mount
Splice Access
BD
Barn Doors
Pole Mount Tee
GS
Glare Shield
Stan. Mount Tee
Ext. Wall Mount
Pole Arm Round,4" dia.
Pole Arm Round,5" dia.
Pole Arm Round,6" dia.,
Pole Arm Square,4" sq.
Pole Arm Square,5" sq.
Pole Arm Square,6" sq.
Pole Arm Twin Round,4" dia.
Pole Arm Twin Round,5" dia.
Pole Arm Twin Round,6" dia.
Pole Arm Twin Square,4" sq.
Pole Arm Twin Square,5" sq.
Pole Arm Twin Square,6" sq.
Finish
BL
BZ
DDB
DNA
GN
GR
SND
STG
TVG
WH
CF
Listing
Black
IEC International
Electrotechnical
Bronze
Commission
Dark Bronze
Natural Alum.
Green
Gray
Sand
Steel Gray
Terra Verde Green
White
Custom
U.L. and C.U.L. Listed for
wet locations.
NEMKO CE N
IP 65 Rating
Hydrel is an ISO9001
Certified Manufacturer
61
SPECIFICATIONS / ORDERING GUIDE – 7100 SERIES
Description
The 7100 Series Flood Light is a compact, high performance
outdoor fixture accommodating lamps to 175 Watt HID.
This unit is designed to provide consistent styling within
Hydrel’s floodlighting systems. With a wide variety of
vertical and horizontal light distributions, and mounting
options, the 7100 greatly extends the uniform lighting
capabilities of lower to mid-level floodlights. This fixture is
fully sealed and suitable for wet locations.
Features & Specifications
MATERIAL: Die cast aluminum housing and door.
LAMP:
Incandescent: T-3, RSC Quartz to 500 Watts, T-4, Minican to
250 Watts.
HID: T-6, G12 to 150 Watts, E-17 medium base to 175 Watts;
Elliptical, E-27 to 150 Watts. See ordering guide for further
lamp options.
LENS: Flat tempered glass.
MOUNTING: See ordering guide below, Mounting Options and
Accessories on page 48, and Mounting Option chart on page 64
for comprehensive list of mounting capabilities.
Knuckle or yoke mounted (180° vertical, 360° rotation); Fixed
mounted for ceiling or wall.
Knuckle Mount: Die cast aluminum with 3/4" NPT galvanized
nipple standard.
Yoke Mount: Aluminum with 10' of 18-3 STW flexible cord for US
standard, 3m of 3GX1.0mm HO7RN-F cable for European
standard. Polymer yoke mount caps are black finish.
GLARE CONTROL: Internal glare control elements, external
adjustable barn doors or fixed glare shields available.
ELECTRICAL COMPONENTS: Integrally mounted ballasts rated for
low starting temp. Fixtures are 100% factory tested.
SOCKET:
Incandescent: Recessed Single Contact (RSC), Minican
screw base.
HID: G-12, medium, or E27 base pulse-rated 4KV.
See ordering guide below for further lamp options.
FINISH: See ordering guide below for colors.
VOLTAGE: See ordering guide below.
WEIGHT: 37 lbs.
LIGHT DISTRIBUTION: See ordering guide below.
EPA: 1.27
REFLECTORS: High purity anodized specular, semi-specular,
patterned lighting sheet in various configurations
designed to provide maximum performance and
uniformity.
NOTE: All lamps must be rated for “Universal Burning Position”
because fixture tilt changes lamp orientation.
Model
Wattage & Lamp
U.S.
7100
Incandescent
250Q
T4
250QB NA
300Q
T3
300QB NA
400Q
T4
500Q
T3
300TH
NA
Metal Halide
70M
ED17
70CM
ED17
100M
ED17
100CM ED17
150M
ED17
175M
ED17
70CMT6 T6
150CMT6 T6
70HQI
T6
70CMTD T6
150HQI T7
150CMTD T7
EUROPEAN
MC NA
Tub. BA15d
RSC NA
Tub. BA15d
MC NA
MC NA
Tub. RX7
med.
med.
med.
med.
med.
med.
G12
G12
RSC
RSC
RSC
RSC
Ellip.
Ellip.
Ellip.
Ellip.
Ellip.
NA
T6
T6
Tub.
T6
Tub.
T7
FASTENERS: Stainless steel
LISTING: U.L., C.U.L., CE, NEMKO
Voltage
Distribution
Mounting
Mounting Acc.
U.S. EUROPEAN
120 22050HZ
208 23050HZ
220 24050HZ
240
277
347
120/277
480
TB
NSP 1
NHSP
SP
HSP
HFL 2
VFL
WFL
KM
Knuckle Mount
YM
Yoke Mount
3
CM
Ceiling Mount
WMS 3 Wall Mount
Side
WUS 3 Wall Mount
Side up
ARJB 4
FJB 4
PSSA
Nar. Spot
Nar. Hor. Spot
Spot
Hor. Spot
Hor. Flood
Vert. Flood
Wide Flood
HPS
70S
100S
150S
E17
E17
E17
med. Ellip. E27
med. NA
med. NA
MV
75H
80H
100H
125H
E17
NA
E17
NA
med. NA
Ellip. E27
med. NA
Ellip. E27
TRJB
WMSA
PMSA
E27
E27
E27
E27
E27
G12
G12
RX7
RX7
RX7
RX7
SMSA–––5
1
2
3
4
5
6
7
8
9
10
11
12
13
Available with 70CMT6, and 150CMT6 lamps only
Not available with RSC or R75 base lamps
Not available with mounting accessories
See individual spec sheet for conduit options
Available in 6" increments from 12" to 48",specify length
Two fixtures per mounting
Available in 6" increments from 12" to 24", specify length
Not available with VFL or WFL distributions
Options mutually exclusive
Not available with CM mounting
Available with 120V or 277V only
Available with 208V, 240V, or 347V only
Not available with 480Volts, NSP, and HSP distribution
PMT 6
SMT 6
EWM –––5
PAR4/–––7
PAR5/–––7
PAR6/–––7
PAS4/–––7
PAS5/–––7
PAS6/–––7
PATR4/–––6,7
PART5/–––6,7
PART6/–––6,7
PAST4/–––6,7
PAST5/–––6,7
PAST6/–––6,7
Accessories
Arch. J-Box
Internal
Flush J-Box
ISS 8
Int. Source Shield
Ped. Stan. Mt. 7" CFAMB Color Filter Amber
Splice Access
CFRED
Color Filter Red
Stanchion Mount
CFBLU Color Filter Blue
Splice Access
Tree Mt. J-Box
CFGRN Color Filter Green
Wall Mount
External 9
Splice Access
BD
Barn Doors
Pole Mount
GS 10 Glare Shield
Splice Access
LC 10 Polycarbonate
Pole Mount Tee
Cover
Stan. Mount Tee
Ext. Wall Mount
Pole Arm Round,4" dia.,
Pole Arm Round,5" dia.,
Pole Arm Round,6" dia.,
Pole Arm Square,4" sq.
Pole Arm Square,5" sq.
Pole Arm Square,6" sq.
Pole Arm Twin Round,4" dia.
Pole Arm Twin Round,5" dia.
Pole Arm Twin Round,6" dia.
Pole Arm Twin Square,4" sq.
Pole Arm Twin Square,5" sq.
Pole Arm Twin Square,6" sq.
Options
Finish
Fusing
SF 11 Single Fuse
DF 12 Double Fuse
Photo Control
Photo Cell
PE
Re-Strike
QRS12,13 Quartz
Emergency
Re-Strike
BL
BZ
DDB
DNA
GN
GR
SND
STG
TVG
WH
CF
Lamp
LPI Lamp
Included
U.L. and C.U.L. Listed for
wet locations.
NEMKO CE N
IP 65 Rating
Hydrel is an ISO9001
Certified Manufacturer
Listing
Black
IEC International
Electrotechnical
Bronze
Dark Bronze Commission
Natural Alum.
Green
Gray
Sand
Steel Gray
Terra Verde Green
White
Custom
62
SPECIFICATIONS / ORDERING GUIDE – 7200 SERIES 400 WATT
Description
The 7200 Series of outdoor lighting fixtures is designed to provide
consistent styling with a variety of light distributions. Styling is
consistent with the smaller companion 7000 and 7100 Series units.
Multiple optical systems achieve a wide variety of vertical and
horizontal light distributions, from tight spots to wide floods.
A variety of mounting orientations are available including wall,
stanchion, base, knuckle, yoke, and pole mounts.
Features & Specifications
LENS: Flat tempered glass.
MOUNTING: See ordering guide below, Mounting Options and
Accessories on page 52, and Mounting Option chart on page 64
for comprehensive list of mounting capabilities.
Fixtures can be knuckle or yoke mounted (180° vertical, 360°
rotation) on pole, stanchion, wall, or tenons. All mounting
accessories are aluminum, secured with stainless steel fasteners.
GLARE CONTROL: Internal glare control elements, external
adjustable barn doors or fixed glare shields available.
MATERIAL: Die cast aluminum housing and door.
LAMP: HID to 400 Watts.
ELECTRICAL COMPONENTS: Integrally mounted ballasts rated
for low starting temp. Fixtures are 100% factory tested.
SOCKET: Porcelain mogul base rated 5KV.
FINISH: See ordering guide for colors.
VOLTAGE: See ordering guide below.
FASTENERS: Stainless Steel
LIGHT DISTRIBUTION: See ordering guide below.
LISTING: U.L., C.U.L., C.E., NEMKO
REFLECTORS: High purity anodized specular, semi-specular, or
patterned lighting sheet in various configurations to provide
optimum optical performance. Reflectors are interchangeable
using four screws and quick-release electrical connectors
(with the exception of spot reflectors.) Reflectors include
both segmented and hydroformed types to provide maximum
performance and uniformity.
Model
Wattage & Lamp
U.S.
7200
Metal Halide
200M 1,2 ED28
250M
ED28
320M1 ED28
1,2
350M
ED28
400M
ED37
HPS
250S
400S
Voltage
EUROPEAN
mog.
mog.
mog.
mog.
mog.
E90 or Ellip. E40
E90 or Ellip. E40
E90 or Ellip. E40
E90 or Ellip. E40
E120 or Ellip. E40
ED18 mog. Ellip. or Tub. E40
ED18 mog. Ellip. or Tub. E40
Distribution
Mounting
WEIGHT: 50 lbs.
EPA: 3.00
NOTE: All lamps must be rated for “Universal Burning Position”
because fixture tilt changes lamp orientation.
Accessories
Internal
Spot
KM Knuckle Mount
ISS 5
Int. Source Shield
Hor. Spot
YM Yoke Mount
CFAMB Color Filter Amber
Narrow Hor. Spot
CFRED Color Filter Red
Hor. Flood
Mounting Acc.
CFBLU Color Filter Blue
Vert. Flood
13
CFGRN Color Filter Green
Wide Flood
EWM–––
Extended Wall Mount
PSSA
Ped. Stan. Mt. 7"
External 14
Splice Access
BD
Barn Doors
SMSA–––12 Stanchion Mount
GS
Glare Shield
Splice Access
LC
Polycarbonate Cover
3
TNM
Tenon Mount
6
EGL
Ext. Grid Louver
SMT 4
Stanchion Mount Tee
4
PMT
Pole Mount Tee
PAR4/–––15 Pole Arm Round,4" dia.
PAR5/–––15 Pole Arm Round,5" dia.
PAR6/–––15 Pole Arm Round,6" dia.
1 Available only with SCWA ballast
PAS4/–––15 Pole Arm Square,4" sq.
2 200M and 350M are not available with SP distribution
PAS5/–––15 Pole Arm Square,5" sq.
3 For use with KM only
PAS6/–––15 Pole Arm Square,6" sq.
4 Two fixtures per mounting
PATR4/–––4,15 Pole Arm Twin Round,4" dia.
5 Not available with WFL distribution
PART5/–––4,15 Pole Arm Twin Round,5" dia.
6 EGL accessory available in flat black finish only
PART6/–––4,15 Pole Arm Twin Round,6" dia.
7 Available with 120V or 277V only
PAST4/–––4,15 Pole Arm Twin Square,4" sq.
8 Available with 208V, 240V, or 347V only
PAST5/–––4,15 Pole Arm Twin Square,5" sq.
9 Not available with 480V, TBV, or NHSP
PAST6/–––4,15 Pole Arm Twin Square,6" sq.
10
U.S. EUROPEAN
120 22050HZ
208 23050HZ
220 24050HZ
240
277
347
480
120/277
TB
TBV
SP
HSP
NHSP
HFL
VFL
WFL
Available only with 250M or 400M
11 Available only with 200M, 250M, 320M, 350M,or 400M
12 Available in 6" increments from 12" - 48" - specify length
13 Available in 6" increments from 18" - 36" - specify length
14 Options mutually exclusive
15 Available in 6" increments from 12" to 24"- specify length
Options
Lamp
Fusing
LPI Lamp
Included
Single Fuse
SF 7
DF 8
Double Fuse
Photo Control
Photo Cell
PER
Re-Strike
9
Quartz
QRS
Emergency
Re-Strike
Ballasting
10 Constant Wattage
CWA
Ballast
SCWA11 Super CWA
Pulse Start
Finish
U.L. and C.U.L. Listed for
wet locations.
NEMKO CE N
IP 65 Rating
Hydrel is an ISO9001
Certified Manufacturer
Listing
BL Black IEC International
Electrotechnical
BZ Bronze
DDB Dark Bronze Commission
DNA Natural Alum.
GN Green
GR Gray
SND Sand
STG Steel Gray
TVG Terra Verde Green
WH White
CF Custom
Form No. 106.20 8 / 04
12881 Bradley Avenue, Sylmar, CA 91342
T 818.362.9465 F 818.362.6548
Email: custserv@hydrel.com
www.hydrel.com
©2004 Acuity Brands Inc. All rights reserved. “Hydrel” is a trademark of Acuity Brands Inc.
63
SPECIFICATIONS / ORDERING GUIDE – 7200 SERIES 1000 WATT
Description
The 7200 Series Architectural Lighting System is a series
of outdoor fixtures designed to provide consistent styling
with a wide variety of vertical and horizontal light
distributions. These luminaires greatly extend the uniform
lighting capabilities for low level floodlights. Multiple
optical systems achieve a wide variety of vertical and
horizontal light distributions, from horizontal spot to
vertical floods. There are also a variety of mounting
options available including wall, stanchion, base, knuckle
and yoke mounts. Fixture is fully sealed with silicone
gasketing, suitable for wet location.
LENS: Flat tempered glass.
MOUNTING: See ordering guide below. Mounting Options and
Accessories on page 53, and Mounting Option chart on page 64
for comprehensive list of mounting capabilities.
Fixtures can be knuckle or yoke mounted (180° vertical, 360°
rotation) on pole, stanchion, wall, or tenons. All mounting
accessories are aluminum, secured with stainless steel fasteners.
GLARE CONTROL: Internal glare control elements, external
adjustable barn doors or fixed glare shields available.
Features & Specifications
ELECTRICAL COMPONENTS: Externally mounted ballasts.
MATERIAL: Die cast aluminum housing and door.
FINISH: See ordering guide.
LAMP: HID to 1000 Watts
FASTENERS: Stainless steel.
SOCKET: Porcelain mogul base rated 5 KV.
LISTING: U.L., C.U.L.
VOLTAGE: See ordering guide below.
WEIGHT: 40 lbs. (head only)
LIGHT DISTRIBUTION: See ordering guide below.
EPA: 3.00
REFLECTORS: High purity anodized specular, semi-specular,
or patterned lighting sheet in various configurations to
provide optimum optical performance. Reflectors are
interchangeable using four screws and quick-release
electrical connectors (with the exception of spot reflectors).
Reflectors include both segmented and hydroformed types
to provide maximum performance and uniformity.
NOTE: All lamps must be rated for “Universal Burning Position”
because fixture tilt changes lamp orientation.
Model
Wattage & Lamp
Voltage
Distribution
Mounting
Mounting Acc.
Accessories
7200
Metal Halide
1000M Reduced
envelope BT-37
1000S Reduced
envelope ED-37
U.S. EUROPEAN
120 22050HZ
208 23050HZ
220 24050HZ
240
277
347
480
120/277
TB
TBV
SP
Spot
HSP Hor. Spot
NHSP Narrow Hor. Spot
HFL Hor. Flood
VFL Vert. Flood
WFL Wide Flood
KM Knuckle Mount
YM Yoke Mount
SMB
SMBEWM
SMBPMT 1
SMBSMSA
SMBSMT 1
SMBTNM 2
Fusing
Internal
ISS 3 Int. Source Shield SF 5 Single Fuse
DF 6 Double Fuse
External 4
Photo Control
BD Barn Doors
PER Photo Cell
GS Glare Shield
EGL Ext. Grid Louver
Re-Strike
QRS 7 Quartz
Emergency
Re-Strike
Ballasting
8
CWA
1
2
3
4
5
6
7
8
Two fixtures per mounting
For use with KM only
Not available with WFL distribution
Options mutually exclusive
Available with 120V or 277V only
Available with 208V, 240V, or 347V only
Not available with 480V, TBV, or NHSP distribution
Available with 1000M only
Surface Mounted Ballast
SMB Extended Wall Mount
Pole Mount Tee
SMB Stanchion Mount
SMB Stanchion Mount Tee
SMB Tenon Mount
Options
Lamp
Finish
LPI Lamp
Included
BL Black
IEC International
Electrotechnical
BZ Bronze
DDB Dark Bronze Commission
DNA Natural Alum.
GN Green
GR Gray
SND Sand
STG Steel Gray
TVG Terra Verde Green
WH White
CF Custom
U.L. and C.U.L. Listed for
wet locations.
NEMKO CE N
IP 65 Rating
Hydrel is an ISO9001
Certified Manufacturer
Listing
64
MOUNTING OPTIONS
*
*
*
*
*
*
No
Mo
unt
ing
AR
Ac
JB
ces
Arc
sor
hite
FJ
ies
B
ctu
Ava
Flu
ral
s
ilab
h
Jun
PM
J
le
u
ctio
SA
nct
ion
nB
Po
ox
le M
Bo
PM
x
T
oun
Po
t
le M
SM
o
SA
unt
Tee
Sta
PS
nch
SA
ion
Pe
Mo
des
SM
unt
tal
T
Sta
Sta
n
n
c
WM
chi
hio
on
n M
SA
Mo
Wa
oun
unt
TR
l
l
t
Mo
JB
Tee
unt
Tre
eM
EW
oun
M
Ext
t Ju
end
TN
nct
M
ion
ed
Ten
Wa
Bo
ll M
x
on
PA
Mo
oun
RP
unt
t
ole
Arm
PA
SP
Ro
ole
und
Arm
PA
TR
S
qu
Po
are
le A
PA
rm
TS
Tw
Po
in R
le A
SM
oun
rm
BS
d
Tw
MB
in S
SM
Mo
q
uar
BE
unt
e
WM
SM
SM
BS
B
MS
Ext
AS
SM
end
MB
BS
ed
MT
Wa
Sta
ll M
SM
SM
nch
oun
BS
BP
ion
tan
MT
t
Mo
chi
SM
SM
unt
on
BP
BT
T
e
NM
eM
ole
oun
SM
Tee
SM
BR
t
BT
Mo
eno
unt
SM
nM
BR
oun
em
ote
t
Mo
unt
MOUNTING ACCESSORIES
MOUNTING OPTIONS
7000 Series
26 Watt to 70 Watt
ADJUSTABLE
Knuckle Mount
KNUCKLE
Yoke Mount
7100 Series
YOKE
* ●*
●* ●*
● ● ● ●
●
●
● ●
●
● ●
●
●
*
*
●
● ●
● ● ●
*
●*
●
● ●
●
●
● ● ● ●
●
●
● ●
●
● ●
●
●
*
*
●
● ●
● ● ●
*
●*
●
● ●
●
●
● ●
●
●
●
●
● ●
●
*
●*
●
●
●
●
50 Watt to 175 Watt
ADJUSTABLE
Knuckle Mount
Yoke Mount
KNUCKLE
YOKE
* ●*
●* ●*
FIXED
Wall Mount Side down/up
Ceiling Mount
7200 Series
WMS / WUS
●
CM
●
400 Watt
ADJUSTABLE
Knuckle Mount
Yoke Mount
7200 Series
KNUCKLE
YOKE
*
*
●
* ●*
●* ●*
● ●
●
1000 Watt
ADJUSTABLE
Knuckle Mount
Yoke Mount
KNUCKLE
●
● ●
YOKE
●
● ●
*
● Two fixtures per mounting
* *
●* ●*
● ●
●
●
●
●
65
Protected Performance
Lighting an American landmark with
Hydrel Series 7200 luminaires.
A project to update the lighting at
Hoover Dam resulted in replacing sixtyfour HPS fixtures with thirty-two 1000
Watt Metal Halide Series 7200 units
using a combination of flood and spot
distributions.
Uniformity and color rendering
improved dramatically, while operating
costs dropped by 23%.
The sturdy 7200s were chosen for their
performance and rugged construction.
The units are knuckle mounted on
remote ballast enclosures to provide
easy adjustment.
7200 MH 1000 spot and
flood fixtures on surface
mounted ballast enclosures
aimed for maximum impact
on the face of the dam.
Download