ARCHITECTURAL FLOODLIGHTING 7000 FAMILY 7000 SERIES 7100 SERIES 7200 SERIES THE HYDREL 7000 FAMILY ARCHITECTURAL LIGHTING SYSTEM FLOODLIGHTS The Hydrel 7000 Family of floodlights is comprised of the 7000 Series, 7100 Series, and 7200 Series. 1 CONTENTS 2-9 THE 7000 FAMILY / PERFORMANCE 10-17 7000 SERIES 18- 27 7100 SERIES 28-37 7200 SERIES 38- 41 PRODUCT APPLICATION GUIDE 42- 45 PROTECTED PERFORMANCE (CONSTRUCTION & FEATURES) 46- 47 MOUNTING OPTIONS / ACCESSORIES / DIMENSIONS - 7000 SERIES 48- 51 MOUNTING OPTIONS / ACCESSORIES / DIMENSIONS - 7100 SERIES 52- 57 MOUNTING OPTIONS / ACCESSORIES / DIMENSIONS - 7200 SERIES 58- 59 FINISH OPTIONS - STANDARD AND CUSTOM 60- 63 PRODUCT SPECIFICATIONS / ORDERING GUIDE 64 MOUNTING OPTION GUIDE 2 PRESENTING THE HYDREL 7000 FAMILY AN ARCHITECTURAL LIGHTING SYSTEM FOR THE 21st CENTURY HIGH PERFORMANCE ILLUMINATION for LONG LASTING SOLUTIONS 3 ARCHITECTURAL LIGHTING FOR THE 21st CENTURY 7000 Series 7100 Series 7200 Series 26Watts to 70Watts 50 Watts to175 Watts 250 Watts to1000 Watts From Hydrel – the industry leader in sealed fixtures – a family of rugged contemporary floodlights providing long lasting solutions for a wide range of applications from 26 Watts fluorescent to1000 Watts HID. The 7000 Series Luminaires Compact, high performance fixtures accommodate lamps to 70 Watt HID. Numerous mounting possibilities are available for both knuckle and yoke fixtures, all achieved with a consistent styling theme. Five optical systems create a wide variety of vertical and horizontal light distributions, from tight spots to wide floods. Page 10 The 7100 Series Luminaires Mid-sized fixtures designed for lamps to 175 Watt HID set the industry standard for performance. Available mounting possibilities include knuckle, yoke, wall, ceiling, and pole fixtures – all implemented with a consistent styling theme. Seven optical systems permit a wide variety of vertical and horizontal light distributions, from narrow spots to wide floods. Page 18 The 7200 Series Luminaires Large scale fixtures accommodate lamps to1000 Watt HID. Multiple mounting possibilities are available for knuckle, yoke, wall, and pole fixtures with a consistent styling theme. Six optical systems allow a wide variety of vertical and horizontal light distributions, from spots to wide floods. Page 28 4 HIGH PERFORMANCE ILLUMINATION Hydrel is an industry leader in three prime areas of high performance illumination: BEAM CONTROL, GLARE CONTROL, and COLOR CONTROL Performance Solves Problems. Hydrel provides the highest quality Architectural and Landscape Floodlights. The optical performance of the 7000 Family has the capability to solve many lighting problems. Highest attention is paid to beam control, glare control, and color control in the design of these fixtures. Beam Control Hydrel optical systems deliver excellent beam and distribution control, offering numerous choices for architectural and landscape applications. Reflector designs use hydroformed and/or segmented aluminum elements with diffuse or specular surfaces to produce precise distributions, including: spots, horizontal spots, narrow horizontal spots, wide floods, vertical floods, and horizontal flood distribution. The 7000 Family accommodates a wide variety of light distributions 7000 SERIES 7100 SERIES 7200 SERIES 5 Floodlighting Distributions (see page 14) 7 Floodlighting Distributions (see pages 22-23) 6 Floodlighting Distributions (see pages 32-33) 5 A single 7100 Series 100 Watt Metal Halide fixture with a vertical flood distribution illuminates this building. Vertical flood distribution is excellent for walls and buildings. 7200 Series 400 Watt Metal Halide flood lights illuminate the top of the Chrysler Building replica at New York, New York Casino in Las Vegas. 7200 Series 250 Watt Metal Halide floodlights illuminate the area behind this large statue at Hollywood and Highland in Los Angeles. 7200 Series luminaires, employing 250 and 400 Watt Metal Halide lamps uplight the Los Angeles City Hall. Fixtures are located at the building base, in the tower, and on the roof. 6 HIGH PERFORMANCE ILLUMINATION Glare Control Grid Louver (EGL) External Glare Control A flat black aluminum grid mounted in the door channel with set screws reduces glare from various viewing angles. Barn Doors (BD) Glare Shield (GS) Each door is independently mounted with set screws in the door channel. Use up to four doors. Custom door lengths available. Cuts off upward glare at 35°,side glare at 50° from beam center. A formed aluminum shield, mounted in door channel by set screws, cuts off upward glare at 35° from beam center. 35° 35° 50° Dark Sky and Light Trespass An increasingly important feature of optical performance is glare control. Dark sky and light trespass legislation are a concern for designers. Hydrel offers external glare control for all of its outdoor product lines including louvers, shields, and barn doors. With the recent introduction of new flood, ingrade, and accent fixtures, Hydrel has introduced internal glare controls to eliminate the inconveniences of external accessories. The internal controls use source shields and baffles to eliminate inefficient, unwanted light. Internal and external glare controls are illustrated here. A bank of 7200 Series fixtures equipped with 400 Watt Metal Halide lamps with narrow spot distribution illuminates a row of 100-foot-tall palms at Morton’s in Costa Mesa, California. This temple is beautifully illuminated using 7100s with Incandescent sources and wide flood distribution located inside the structure. Stowe Landscape Gardens, National Trust. "Temple of Ancient Virtue" Lighting by Lightscape Projects Ltd, London Photo: Tim Soar This sixty-foot-long sign is lighted by two 7100s with Horizontal Spot, 100 Watt Metal Halide sources. Located fifteen feet from the sign, they provide excellent uniformity with minimum spill light. The internal glare control minimizes glare to passers-by. 7 Internal Source Shields / Glare Control Internal Glare Control The 7000 Series features internal glare control options for a number of distributions including spots, horizontal floods, and horizontal spots. These shields fasten internally, eliminating glare outside the desired distribution pattern. Internal source shields (ISS) eliminate the need for external glare control devices such as half glare shields and barn doors – providing clean, architecturally pleasing surfaces. without internal source shield with internal source shield Light distribution with and without Internal Source Shield The tower and colonnade at the Bellagio Casino in Las Vegas are lighted by Hydrel 7200 Series 400 Watt Metal Halide floodlights. 7100 Series spots with Incandescent sources beautifully illuminate this memorial. The mirror effect enhances its beauty. Stowe Landscape Gardens, National Trust. "Palladium Bridge" Lighting by Lightscape Projects Ltd, London Photo: Tim Soar Swashes of color highlight walls of this interior courtyard. 7100 Series floodlights with 100 Watt colored Metal Halide lamps illuminate the Kaiser Permanente Medical Center parking structure in Fontana, California. 8 HIGH PERFORMANCE ILLUMINATION Color Control Color is an important parameter for lighting designers. Hydrel has been at the forefront in providing split glass and dichroic filters for a wide range of projects. The illustrations here show applications with the 7000 Family using filters and colored lamps. Basic sources such as Metal Halide, Incandescent, Halogen, and High Pressure Sodium produce their own distinct spectra and resultant colors. Color filtering can alter the basic light source to produce desired effects. One must also consider the reflective characteristics of the lighted surface and the perception of the human eye as well as ambient conditions. Dark colored filters will result in some light loss with heat generation. Dichroic filters, which assist in heat transfer, are commonly used for these applications. Contact Hydrel for assistance. This wall screams excitement. Three 7100s use 100 Watt Metal Halide sources with color filters to bring this building to life. Two units employ spot distributions and the third uses a horizontal flood distribution. The 7100 provides an outdoor luminaire with a theatrical effect. A series of split glass filters on a test wall, all fitted to a 7100 Series flood using varying wattages depending on the color of filter being tested. These and other filter colors are available from Hydrel. Medium Amber Medium Green Medium Blue Magenta Light Blue Red 9 7100 Series spots and vertical floods light this building with and without color filters. The photos show the same building with the same lighting setup except for the addition of colored filters in the photo to the right. Hydrel recommends the use of mockups to ensure that desired effects are attained. Based on successful projects, a number of filters and recommend sources have been cataloged to simplify selection. Below, two 100 Watt Metal Halide spots cast a blue grazing beam on the left and a green highlight on a distant tower. This lobby is uplighted with 100 Watt Mercury Vapors and Metal Halides using symmetrical distributions. 10 7000 SERIES ARCHITECTURAL LIGHTING SYSTEM Lighting on the magical Eiffel Tower replica at the Paris Casino in Las Vegas includes over seven hundred 7000 Series fixtures. 11 7000 SERIES 7000 Series 7100 Series 7200 Series 26 Watts to70Watts 50 Watts to175 Watts 250 Watts to1000 Watts Hydrel 7000 Series Small Floodlights This small, high performance 7000 Series flood light capitalizes on Hydrel's proven reflector and glare control designs to provide performance previously available only in large fixtures. 113/4 298 5 3/4 146 6 153 A 7000 Series spot is shown here on a yoke mount. Its contemporary styling will complement any architectural statement. 12 7000 SERIES This compact fixture fulfills numerous architectural and landscape applications. The 7000 Series provides equivalent spot and fluorescent flood performance in a housing only half the size of larger fixtures. Intelligent Design Hydrel attends to details to assure the designer that a quality product is placed on the job. Owners can expect excellence and long product life from the leader in the design of sealed fixtures. The 7000 Family delivers protected performance. Mounting Versatility A wide variety of 7000 Series mounting options are available. Stanchion Tee Mount shown above, Yoke Mount on Architectural Junction Box shown to right. Protected Performance Protection: • Rugged die cast housings and doors • Tough mountings • Stainless steel fasteners • Self-sealing silicone door gaskets • Tempered glass lenses • Textured powder coat finishes Performance: • High efficiency reflectors • Variety of standard NEMA patterns • Internal & external glare control • Lockable aiming • Wide dynamic range – 26Watt Fluorescent to 70 Watt HID • Low energy, efficient Fluorescent to high intensity HID. • High power factor magnetic and electronic ballasts • Ease of installation and maintenance Performance New efficient lamps and reflectors allow designers to downsize to this small onequarter cubic foot flood light. Construction Critical sealing to prevent water intrusion is accomplished with Hydrel's proven “floating door” design, in which the silicone gasketed lens and door assembly fasten to internal bracketry ensuring even sealing pressures. 7000 Knuckle Mount on Architectural Junction Box. 13 Compact The 7000 Series is slightly larger than conventional accent lights yet provides significant photometric advantages – increased distributions, uniformity, and glare control. 7000 Series next to a typical accent light. Up to 70 Watt Metal Halide spots with internal glare control. Glare Control Internal and external glare control options are available on all 7000 Series models. Available with a wide range of accessories, including Architectural Junction Boxes, Stanchion Mounts, Tree Mounts, Wall Mounts, and Pole Mounts. Low Energy 42 Watt PLT Fluorescent Floods – previously available only in larger fixtures. U.L. and C.U.L. Listed for wet locations. NEMKO CE N IP 65 Rating Hydrel is an ISO9001 Certified Manufacturer 14 BEAM CONTROL – 7000 SERIES Five Floodlight Optical Systems TSP Tight Spot For applications requiring a pattern with a tight, concentric beam. Optional Internal Glare Control Source Shield (ISS) TSP 70W MH T6 50% Beam 13°x11° Max Candel 48,042 20' Beam shown: 70 Watt Metal Halide lamp with optional internal source shield (ISS). Fixture 6 feet from test wall. NHSP Narrow Horizontal Spot For applications requiring a horizontal beam. MFL Medium Flood FL Flood FL Fluorescent Flood For applications requiring a pattern with a wide, concentric beam. For applications requiring a wide horizontal pattern. For applications requiring a wide horizontal pattern. Standard Internal Linear Spread Filter (LSF) NHSP 70W MH T6 50% Beam 56°x15° Max Candel 4,157 20' Beam shown: 70 Watt Metal Halide lamp with standard linear spread filter (LSF). Fixture 6 feet from test wall. MFL 70W MH T6 50% Beam 16°x13° Max Candel 27,191 20' Beam shown: 70 Watt Metal Halide lamp. Fixture 6 feet from test wall. FL 70W MH E17 50% Beam 73°x 99° Max Candel 1,440 20' Beam shown: 70 Watt Metal Halide lamp. Fixture 6 feet from test wall. FL 42W Fluor. TRT 50% Beam 78°x111° Max Candel 571 20' Beam shown: 42 Watt Fluorescent lamp. Fixture 6 feet from test wall. 15 PERFORMANCE – 7000 SERIES Architectural Detail Below, 7000 Series illuminates classic column and building details with a 70 Watt Metal Halide lamp in medium flood distribution. University Building Left, big performance from a small fixture – three 7000 Series fixtures with 70 Watt Metal Halide lamps illuminate a hall at Pomona College, Claremont, California. Sculpture A 7000 Series fixture with a 35 Watt Metal Halide lamp in spot distribution illuminates a small sculpture. Night Garden Trees uplighted by a 7000 Series fixture with a 70 Watt Metal Halide lamp in flood distribution. 16 PERFORMANCE – 7000 SERIES Large Tree Canopy The 7000 Series is an excellent choice for use in the landscape. Its small size and wide, dynamic range of lighting options allows designers to create many effects. Glare control capabilities keep the light where it is intended. Column Detail A 7000 Series 70 Watt HID floodlight illuminates ornate columns and eaves, while a single 70 Watt HID spotlight accents an adjacent palm. 17 Public Art This artistic piece is easily uplighted with a 7000 Series fixture. Small Sculpture Polished stone sculpture illuminated by a 7000 Series fixture with a 35 Watt Metal Halide in flood distribution. Nightscape Two 7000 Series equipped with 42 Watt Fluorescent lamps highlight a low meandering flowering hedge. Paris Casino, Las Vegas The Eiffel Tower replica at this hotel is illuminated by 7000 Series High Pressure Sodium 35 Watt fixtures attached to tower beams. 18 7100 SERIES ARCHITECTURAL LIGHTING SYSTEM 7100 Series floodlights with 100 Watt filtered Metal Halide lamps illuminate the Kaiser Permanente Medical Center parking structure in Fontana, California. 19 7100 SERIES 7000 Series 7100 Series 26Watts to 70Watts 50Watts to175 Watts 7200 Series 250 Watts to1000 Watts Hydrel 7100 Series Medium Floodlights These workhorse lights provide rugged watertight protection with high performance optical systems designed to meet today’s requirements for light trespass, glare control, and dark skies. 15 3/4 400 6 3 /4 6 3 /4 171 171 91/4 235 Contemporary styling to complement any architectural statement. Shown here is a 7100 Series wide flood on a yoke mount. 20 7100 SERIES Mounting Versatility This medium-size fixture, the workhorse of the 7000 Family, offers a wide range of mounting and glare control options to facilitate its use in a variety of architectural and landscape applications. Intelligent design assures a quality product is placed on the job. Owners can expect long product life and superior performance from the leader in the design of sealed fixtures. The 7000 Family delivers protected performance. Protected Performance Protection: • Rugged die cast housings and doors • Tough mountings • Stainless steel fasteners • Self-sealing silicone door gaskets • Tempered glass lenses • Textured powder coat finishes Side mounted area light. Performance: • High efficiency reflectors • Variety of standard NEMA patterns • Internal & external glare control • Lockable aiming • Wide dynamic range – 50 Watt to 175 Watt HID • Low energy, efficient, high intensity HID • High power factor magnetic and electronic ballasts • Easy installation and maintenance A variety of stanchion and pole mounts allows for single and multiple fixture applications. Pole Mount Tee shown. Construction Rugged yoke mounted fixture on an Architectural Junction Box. Knuckle mount makes a rugged, sealed, compact design. Architectural Junction Box provides a small, sealed entryway for easy access. 21 Ceiling and side mounts offer the option of maintaining architectural consistency with downlights. The Internal Source Shield (ISS) eliminates glare from intense flood lighting, providing an unobtrusive source. Wall Mount accessory (WMSA) with integral splice access is available for up or down lighting. Glare Control External glare shields are available in two forms, the versatile barn doors (BD) above or the simple half shield shown to right. The barn doors can be used individually or as a set and can be added easily in the field. Yoke mount provides easy aiming and adjustments and a clean appearance. The external half shield(GS) is an easy field addition. Distribution U.L. and C.U.L. Listed for wet locations. NEMKO CE N IP65 Rating Hydrel is an ISO9001 Certified Manufacturer A variety of NEMA distributions provides the solution for most applications. From Narrow Spots to Wide Floods, the 7100 Series covers a wide range of distribution. Vertical Flood shown to right. Internal glare controls are an option for spots, horizontal spots, and horizontal floods. These “soft” devices limit glare without altering the clean external surface of the fixture. 22 BEAM CONTROL – 7100 SERIES Seven Floodlight Optical System NSP Narrow Spot SP Spot For applications requiring a high intensity, narrow beam of light. For applications requiring a pattern with a tight, concentric beam of light. Optional Internal Glare Control Source Shield (ISS) NSP 150W MH T6 50% Beam 8°x 8° Max Candel 101,550 20' Beam shown: 150 Watt Metal Halide lamp. Fixture 6 feet from test wall. Shown with optional Internal Source Shield (ISS). NHSP Narrow Horizontal Spot HSP Horizontal Spot For applications requiring a high intensity, narrow horizontal beam of light. For applications requiring a pattern with a tight, concentrated, rectangular beam of light. Optional Internal Glare Control Source Shield (ISS) Optional Internal Glare Control Source Shield (ISS) Optional Internal Glare Control Source Shield (ISS) SP 175W MH ED17 50% Beam 21°x15° Max Candel 40,749 NHSP 175W MH ED17 50% Beam 82°x16° Max Candel 14,680 HSP 175W MH ED17 50% Beam 81°x 49° Max Candel 6,383 20' Beam shown: 175 Watt Metal Halide lamp. Fixture 6 feet from test wall. Shown with optional Internal Source Shield (ISS). 20' 20' Beam shown: 175 Watt Metal Halide lamp. Fixture 6 feet from test wall. Shown with optional Internal Source Shield (ISS). Beam shown: 175 Watt Metal Halide lamp. Fixture 6 feet from test wall. Shown with optional Internal Source Shield (ISS). 23 VFL Vertical Flood HFL Horizontal Flood WFL Wide Flood For applications requiring a vertical, rectangular pattern. For applications requiring a wide, horizontal pattern. For applications requiring a beam with a wide, concentric pattern. Optional Internal Glare Control Source Shield (ISS) VFL 175W MH ED17 50% Beam 84°x 84° Max Candel 5,016 20' Beam shown: 175 Watt Metal Halide lamp. Fixture 6 feet from test wall. HFL 175W MH ED17 50% Beam 114°x 37° Max Candel 7,600 20' Beam shown: 175 Watt Metal Halide lamp. Fixture 6 feet from test wall. Shown with optional Internal Source Shield (ISS). WFL 175W MH ED17 50% Beam 30°x 23° Max Candel 20,812 20' Beam shown: 175 Watt Metal Halide lamp. Fixture 6 feet from test wall. 24 PERFORMANCE – 7100 SERIES Facade Detail The 7000 Series (35 Watt HPS) is used to illuminate the facade of the Paris Hotel in Las Vegas, Nevada. Contemporary High Rise Frost Bank Building in Austin, Texas is beautifully illuminated by 7100s with Metal Halide sources in spot and horizontal flood distributions. Turn-of-the Century Structure Hydrel 7100 Series flood lights illuminate the clock tower building at Sun Microsystems headquarters in Palo Alto, California. 25 Directional Sign A 100 Watt Metal Halide source with a horizontal flood distribution in a 7100 Series fitted with an external glare shield highlights a small directional sign Public Sculpture A low wattage Metal Halide lamp in vertical flood distribution set back four feet accents this tall, intricate sculpture. Horizontal Cast Concrete Sign This sixty-foot-long sign is lighted by two 7100s with horizontal spot, 100 Watt Metal Halide sources. Located fifteen feet from the sign, they provide excellent uniformity with minimum spill light. The internal glare control minimizes glare to passers by. Aspen Grove These Aspen trees are illuminated by a 7100 with a Metal Halide source, wide flood distribution – a beautiful winter scene. 26 PERFORMANCE – 7100 SERIES Small Sign Single 7100 Series 100 Watt Metal Halide fixtures are popular for lighting small signs. Large Trees This beautiful deciduous tree changing colors is accented by a 7100 with a vertical flood, 100 Watt Metal Halide source, set back twenty feet. Dense Foliage This setting features a 7100, 100 Watt Metal Halide with horizontal flood distribution beneath the tree and a similar fixture with vertical flood distribution in the foreground. 27 Hollywood Landmark Several 7200 Series Metal Halide spots uplight a large statue at Hollywood and Highland in Los Angeles, California. 28 7200 SERIES ARCHITECTURAL LIGHTING SYSTEM The spectacular 726-foot-high Hoover Dam is illuminated by Hydrel 7200 Series Metal Halide flood fixtures. 29 7200 SERIES 7000 Series 26Watts to 70Watts 7100 Series 7200 Series 50 Watts to175 Watts 250 Watts to1000 Watts Hydrel 7200 Series Large Floodlights Designed for big applications – puts light where you need it with a variety of beam patterns and multiple mounting options as well as internal glare control options for smooth cutoff. 23 3/8 594 10 3/8 264 14 7/16 367 23 584 Contemporary styling to complement any architectural statement. Shown here is a 7200 Series horizontal spot on a knuckle mount. 30 7200 SERIES Large floodlights for big lighting jobs. The 7200’s wide range of mounting and glare control options facilitate its use in a variety of large scale architectural and landscape applications. Intelligent design assures a quality product is placed on the job. Owners and designers can expect long product life and superior quality from Hydrel, leader in the design of sealed fixtures. The 7000 Family delivers protected performance. Construction The 7200 Series displays a clean, architectural shape compatible with a variety of architectural styles. Protected Performance Protection: • Rugged die cast housings and door • Tough mountings • Stainless steel fasteners • Self-sealing silicone door gaskets • Tempered glass lenses • Textured powder coat finishes Performance: • High efficiency reflectors • Variety of standard NEMA patterns • Internal & external glare control • Lockable aiming • Wide dynamic range – 250 Watt to 1000 Watt HID • Low energy, efficient, high performance HID • High power factor, CWA and SCWA magnetic ballasts • Ease of installation and maintenance The rugged 7200 Series knuckle has an integral junction box for a protected wireway. Versatile mountings allow protection, easy aiming, and access. Narrow Horizontal Spot with Internal Source Shield. U.L. and C.U.L. Listed for wet locations. NEMKO CE N IP 65 Rating Hydrel is an ISO9001 Certified Manufacturer 31 Custom Performance The 7200 Series includes several unique fixtures for a variety of lighting applications. Surface Mounted Ballasts, unique to the 7200 Series fixtures, accommodate lamps to1000 Watts HID. Shown here are a wall and base mount. A variety of extensions is available for special mountings. Glare Control External glare shields are offered in two styles. The simple half shield and the versatile barn doors. The barn doors (BD) can be used individually or as a set. These glare shields (GS) are easily added in the field. As shown, a 7200 yoke mount with a half glare shield in a spot distribution. Internal glare controls may be specified as an option for spots, horizontal spots, and horizontal and vertical floods. These “soft” devices limit glare without altering the clean external surface of the fixture Yoke mounts offer easy aiming and adjustment in addition to a clean appearance. The Internal Source Shield (ISS) eliminates glare from intense spot lights providing an unobtrusive source. Horizontal flood with Internal Source Shield (ISS). 32 BEAM CONTROL – 7200 SERIES Six Floodlight Optical Systems SP Spot For large applications requiring a pattern with a tight concentric beam of light. NHSP Narrow Horizontal Spot HSP Horizontal Spot A more concentrated version of the horizontal spot for smaller applications. For applications requiring a pattern with a tight, concentrated rectangular beam of light. Optional Internal Glare Control Source Shield (ISS) Optional Internal Glare Control Source Shield (ISS) Optional Internal Glare Control Source Shield (ISS) SP 400W MH ED37 50% Beam 8°x 8° Max Candel 366,871 NHSP 400W MH ED37 50% Beam 71°x17° Max Candel 30,694 HSP 400W MH ED37 50% Beam 78°x 41° Max Candel 15,521 20' Beam shown: 400 Watt Metal Halide lamp. Fixture 8 feet from test wall. Shown with optional Internal Source Shield (ISS). 20' Beam shown: 400 Watt Metal Halide lamp. Fixture 8 feet from test wall. Shown with optional Internal Source Shield (ISS). 20' Beam shown: 400 Watt Metal Halide lamp. Fixture 8 feet from test wall. Shown with optional Internal Source Shield (ISS). 33 VFL Vertical Flood HFL Horizontal Flood WFL Wide Flood For applications requiring a vertical, rectangular pattern. For applications requiring a wide horizontal pattern. For applications requiring a pattern with a wide concentric beam. Optional Internal Glare Control Source Shield (ISS) Optional Internal Glare Control Source Shield (ISS) VFL 400W MH ED37 50% Beam 84°x 57° Max Candel 10,366 HFL 400W MH ED37 50% Beam 126°x 37° Max Candel 12,768 20' Beam shown: 400 Watt Metal Halide lamp. Fixture 8 feet from test wall. Shown with optional Internal Source Shield (ISS). 20' Beam shown: 400 Watt Metal Halide lamp. Fixture 8 feet from test wall. Shown with optional Internal Source Shield (ISS). WFL 400W MH ED37 50% Beam 50°x 73° Max Candel 17,299 20' Beam shown: 400 Watt Metal Halide lamp. Fixture 8 feet from test wall. 34 PERFORMANCE – 7200 SERIES Large Architectural Complex A bank of 1000 Watt 7200 Series flood /spot lights illuminate the Cinerama Dome in Hollywood, California. 35 Monumental Public Works This spectacular shot of Hoover Dam shows the uniformity achieved by a bank of 1000 Watt 7200 Series Metal Halide fixtures using flood and spot distributions. Industrial Security This 7200 Series Metal Halide flood lights the parking lot at a distribution center in Los Angeles, California. Picture above shows a 400 watt 7200 Series with flood distribution. At left a row of 1000 Watt 7200 Series flood and spot lights at Hoover Dam. Note rear extension for spot distribution. 36 PERFORMANCE – 7200 SERIES Wall Wash These 7200 Series Metal Halide, 250 Watt floods uplight the walls of the New York, New York Casino in Las Vegas. Half glare shields are used in several key locations. Highlight A 7200 Series using a 250 Watt filtered Metal Halide lamp accents the roof on an ice skating rink in Anaheim, California. Tall Palms Morton’s Restaurant, Costa Mesa, California. A row of 100-foot-tall palms is illuminated by a bank of 7200 Series fixtures equipped with 400 Watt, Metal Halide lamps with spot distribution. 37 Large Sculpture These 7200 Series, 400 Watt, Metal Halide fixtures uplight a large statue at Hollywood and Highland in Los Angeles, California. Theme Structure These 7200 Series, 400 Watt, Metal Halide fixtures uplight the base of a large statue at Hollywood and Highland in Los Angeles, California. Large Scale Commercial A bank of eight 7200 Series 1000 Watt spots, seen here to the immediate left mounted on a rooftop, shine across the Hollywood and Highland complex to accent the theme wall seen in photo below. 38 APPLICATION INFORMATION Signs Wattage Distribution Setback Size Small Low Level Horizontal Signs The 7000 family of Architectural Floodlights economizes installation. Advanced photometrics deliver higher lighting levels for your energy dollar. 42TRT 70M 175M 250M FL HSP HSP HSP 3' 4' 6' 8' 4' X 6' 6' X 10' 8' X 12' 16' X 24' Small Low Level Vertical Signs Trees 70M 100M 175M 250M Open Structure 10'-20' MH enhances green 35-50FL MV enhances blue 50-75FL HPS enhances brown 35-50FL 20'- 40' 50-70FL 75-100FL 50-70FL 40'-60' 70-175FL 100-250FL 70-150FL 60'- 80' 175-400FL 250-400FL 250-400FL 10'- 20' 20'- 40' 40'-60' 3' 4' 5' 6' 6' X 3' 10' X 5' 15' X 10' 20' X 10' Large Horizontal Signs Tight Structure MH enhances green 35-50SP MV enhances blue 75-100SP HPS enhances brown 35-50SP FL VFL VFL VFL 60'- 80' 80'+ 50-100SP 70-175SP 175-400SP 1000SP 100-175SP 175-250SP 400SP 50-70SP 70-150SP 250-400SP 1000SP 100M 175M 250M 400M 5' 10' 10' 15' 10' X 20' 20' X 30' 10' X 15' 20' X 30' 4' 6' 8' 10' 10' X 5' 15' X 10' 20' X 15' 30' X 15' Large Vertical Signs 100M 175M 250M 400M ✔ ✐✇ HSP HSP HSP HSP VFL VFL VFL VFL ✓✐✇ ✒✐✇ VFL ✑✐✇ VFL SP SP SP SP WFL VFL FL FL FL FL HSP FL Shown here: FL Flood HFL Horizontal Flood HSP Horizontal Spot MFL Medium Flood VFL Vertical flood WFL Wide Flood SP Spot 39 Flags Walls and Buildings Uplighting For flag sizes 5' to 10' in width Required wattage for pole height & number of fixtures For light colored, smooth concrete walls Pole Ht. 15' 25' 40' 50' 60' 80' 100' 150' 200' Distribution SP SP,NSP SP SP SP SP SP SP SP Wattage single fixture 35M 50-70M 70-100M 150-175M 175-250M 400-1000M 400-1000M 400-1000M 1000M Wattage two fixtures 35M 50-70M 70-100M 150-175M 175-250M 250-400M 250-400M 400-1000M 400-1000M Wattage three fixtures 35M 50-70M 70-100M 150-175M 175-250M 250M 250M 400M 400-1000M Wall height Wattage Distribution Spacing Setback 10' 35-70 FL, VFL 10' 3' 20' 50-100 VFL 10' 4' 30' 175 WFL 10' 5' 40' 250 WFL 20' 10' 50' 250 WFL 20' 10' Required setback from base for pole height and number of fixtures Single fixture 2'- 3' 2'- 3' Pole Ht. 15' to 50' 50' to 200' 2 fixtures 180° apart 1/5 of pole ht. 1/10 of pole ht. 3 fixtures 120° apart 1/5 of pole ht. 1/12 of pole ht. Columns (Uplighting 1'- 3' in diameter) For light colored, smooth concrete columns Column ht. Wattage Distribution Setback 10' 35-70 SP 1' 20' 50-100 SP 1'-2' 30' 70-175 SP 2' 40' 150-250 SP 2' HFL 50' 175-250 SP 2'-3' 60' 250-400 SP 2'-3' HFL HFL HFL WFL VFL VFL MFL MFL SP 60' 400 WFL 20' 10' 40 APPLICATION INFORMATION Signs Wattage Distribution Setback Size Small Low Level Horizontal Signs The 7000 family of Architectural Floodlights economizes installation. Advanced photometrics deliver higher lighting levels for your energy dollar. 42TRT 70M 175M 250M FL HSP HSP HSP 3' 4' 6' 8' 4' X 6' 6' X 10' 8' X 12' 16' X 24' Small Low Level Vertical Signs Trees 70M 100M 175M 250M Open Structure 10'-20' MH enhances green 35-50FL MV enhances blue 50-75FL HPS enhances brown 35-50FL 20'- 40' 50-70FL 75-100FL 50-70FL 40'-60' 70-175FL 100-250FL 70-150FL 60'- 80' 175-400FL 250-400FL 250-400FL 10'- 20' 20'- 40' 40'-60' 60'- 80' 3' 4' 5' 6' 6' X 3' 10' X 5' 15' X 10' 20' X 10' Large Horizontal Signs Tight Structure MH enhances green 35-50SP MV enhances blue 75-100SP HPS enhances brown 35-50SP FL VFL VFL VFL 80'+ 50-100SP 70-175SP 175-400SP 1000SP 100-175SP 175-250SP 400SP 50-70SP 70-150SP 250-400SP 1000SP 100M 175M 250M 400M HSP HSP HSP HSP 5' 10' 10' 15' 10' X 20' 20' X 30' 10' X 15' 20' X 30' 4' 6' 8' 10' 10' X 5' 15' X 10' 20' X 15' 30' X 15' Large Vertical Signs 100M 175M 250M 400M VFL VFL VFL VFL WFL 160' 140' WFL 120' 100' VFL SP SP 80 60 40 20 SP SP VFL SP NSP NSP NSP NSP Shown here: HFL Horizontal Flood HSP Horizontal Spot SP Spot VFL Vertical flood NSP Narrow Spot WFL Wide Flood WFL 41 Flags Walls and Buildings Uplighting For flag sizes 5' to 10' in width Required wattage for pole height & number of fixtures For light colored, smooth concrete walls Pole Ht. 15' 25' 40' 50' 60' 80' 100' 150' 200' Distribution SP SP,NSP SP SP SP SP SP SP SP Wattage single fixture 35M 50-70M 70-100M 150-175M 175-250M 400-1000M 400-1000M 400-1000M 1000M Wattage two fixtures 35M 50-70M 70-100M 150-175M 175-250M 250-400M 250-400M 400-1000M 400-1000M Wattage three fixtures 35M 50-70M 70-100M 150-175M 175-250M 250M 250M 400M 400-1000M Wall height Wattage Distribution Spacing Setback 10' 35-70 FL, VFL 10' 3' 20' 50-100 VFL 10' 4' 30' 175 WFL 10' 5' 40' 250 WFL 20' 10' 50' 250 WFL 20' 10' Required setback from base for pole height and number of fixtures Single fixture 2'- 3' 2'- 3' Pole Ht. 15' to 50' 50' to 200' 2 fixtures 180° apart 1/5 of pole ht. 1/10 of pole ht. 3 fixtures 120° apart 1/5 of pole ht. 1/12 of pole ht. Columns (Uplighting 1'- 3' in diameter) For light colored, smooth concrete columns Column ht. Wattage Distribution Setback 10' 35-70 SP 1' 20' 50-100 SP 1'-2' 30' 70-175 SP 2' 40' 150-250 SP 2' 50' 175-250 SP 2'-3' 60' 250-400 SP 2'-3' VFL WFL HSP HFL HFL HFL HFL 60' 400 WFL 20' 10' 42 PROTECTED PERFORMANCE Stainless steel door retention fasteners are floating and replaceable. Selfcentering door makes a reliable, repeatable seal. Rugged knuckle uses machine tool technology to handle weight, providing 180° vertical tilt adjustment, and 360° rotation to put light where it is needed. A single tamper-proof fastener secures knuckle in position. Angle indicator marks are provided. (See photo on page 44.) Corrosion resistant steel brackets facilitate easy mounting for reflectors and door retention. Ballast wiring and mounting hardware easily accessible for replacement. Wiring harness is covered by a protective plate. High power magnetic factor ballasts mounted to housing allow maximum heat dissipation, long life, and reliable lamp starting. Quick wire disconnects ensure easy reflector installation or removal. Remote enclosures with slide tray mounted ballasts on 1000 Watt lights help reduce component temperature while easing maintenance. Hydrel Flood Lighting Providing Solutions with Protected Performance| The primary function of a lighting fixture body is providing protection for electrical and optical components within. Hydrel, a long time leader in sealed lighting designs, brings its experience and expertise to flood lighting, using heavy die cast components, unique lens sealing methods, and protected wiring. 43 Long lasting silicone gaskets protect against water and insects. Tempered glass lens is permanently bracketed and gasketed to the door to prevent moisture penetration. Heavy duty die cast aluminum door with integral channels for gasketing and accessory retention. The wide lip provides a guide for self centering and positive sealing. The inside of the door is indexed for repeatable positioning of internal glare shields on the door. Internal glare shield eliminates glare outside the desired light distribution pattern. Stainless steel captive door fasteners are provided. Door screw grommet/casting design allows for positive sealing while preventing damage to the grommet through overtightening. U.L. and C.U.L. Listed for wet locations. NEMKO CE N IP 65 Rating Hydrel is an ISO9001 Certified Manufacturer Heavy Duty Knuckle Design The 7000 Series knuckle design, based on heavy duty machine tool technology, features a self releasing taper, allowing infinite vertical adjustment through180° while under heavy load. Rotational range is 360°. Left: Standard knuckle design for the 7000 and 7100 Series fixtures. Right: Heavy duty 7200 Series knuckle configuration with integral junction box. 360° rotation and 180° vertical adjustment with infinite locking positions. 44 PROTECTED PERFORMANCE The 7000 Family delivers protected performance. The Intelligent Design process recognizes that a primary function of a lighting fixture is to provide protection for its electrical and optical components. Hydrel, a long time leader in underwater lighting brings that experience to floodlighting with heavy die cast components, unique lens sealing methods, and protected wiring. Intelligent design assures a quality product is placed on the job. Owners and designers can expect long product life and high quality from Hydrel, the leader in the design of sealed lighting fixtures. Performance: Protection: • • • • • • • • • • • • • • High efficiency reflectors Variety of standard NEMA patterns Internal & external glare control Lockable aiming Wide dynamic range – 26Watt Fluorescent to 1000 Watt HID Low energy, efficient Fluorescent to high intensity HID High power factor magnetic and electronic ballasts Ease of installation and maintenance Rugged die cast housings and door Tough mountings Stainless steel fasteners Self-sealing silicone door gaskets Tempered glass lenses Textured powder coat finishes Color Filters Hydrel remains at the forefront in providing segmented glass and dichroic filters suitable for a wide range of projects. Indexing Indexing scale on inside of door allows for precise positioning of internal glare shields or other devices. Positioning is not disturbed by relamping or other maintenance. Segmented glass filter mounted in a 7100 Series door. Filters attach to the door via the accessory mounting track. Filters can be mounted in conjunction with a glare shield. An array of color filter options are available to enhance lighting applications Heavy Duty Knuckle The 7000 Series knuckle design, based on heavy duty machine tool technology, features a selfreleasing taper, allowing infinite vertical adjustment through 180° while under heavy load. Rotational range is 360°. A single tamperproof fastener secures knuckle in position. Angle indicator pointer is provided; note the raised dot angle indicator marks at 15° intervals. 45 Single Tool Convenience Captive, tamper-proof fasteners retain doors, junction box covers, and knuckles. One common wrench provides maintenance personnel access and aiming ability. U.L. and C.U.L. Listed for wet locations. NEMKO CE N IP 65 Rating Hydrel is an ISO9001 Certified Manufacturer Spring Retention Relamping and maintenance are facilitated by door retention, captured screws, and simple bracketry. Knuckle and yoke mount fixtures use a spring retention system which easily adapts for a variety of mounting options. Visit the Hydrel Website: www.hydrel.com Visit our website for specification sheets, installation instructions, and a comprehensive selection of photometric data for the products in this catalog, as well as for other Hydrel products. Flood lights Area lights Ingrade lights Accent lights Underwater lights Go to www.hydrel.com.– select “floodlights” to supplement the information in this catalog with specification sheets, installation instructions, and photometric data for all models of the 7000 Series of floodlights. Border lights Accessories Custom lights 46 WMSA Wall Mount Knuckle /Yoke 7000 SERIES – MOUNTING Mounting Options KM Knuckle Mount YM Yoke Mount EWM Extended Wall Mount Knuckle / Yoke Mounting Accessories ARJB Architectural Junction Box Knuckle /Yoke PSSA Pedestal Stanchion Mount Knuckle /Yoke TRJB Tree Mount Knuckle /Yoke FJB Flush Mount Junction Box Knuckle /Yoke SMT Stanchion Mount Tee Knuckle /Yoke PMT Pole Mount Tee Knuckle /Yoke SMSA Stanchion Mount Knuckle /Yoke PAR / PAS Pole Arm Round Pole Arm Square Knuckle / Yoke PMSA Pole Mount Knuckle /Yoke (Shown on pole) 7000 SERIES – DIMENSIONS Mounting Options PATR / PATS Pole Arm Twin Round Pole Arm Twin Square Knuckle / Yoke (in inches/millimeters) Mounting Accessories 61/2 3 3/4 18 298 298 EWM 457 Extended Wall Mount 5 3/4 146 6 6 8 1/4 12 - 18 - 24 610 61/2 3 5/8 165 92 PAR4/PAS4 Pole Arm Round Pole Arm Square 6 15 2 5 1/2 18 457 140 13 7/ 8 353 KM Knuckle Mount 7 6 178 457 6 PSSA Pedestal Stanchion Mount 23/8 /8 60 113/4 6 SMSA18 Stanchion Mount 1 153 BD Barn Doors 6 153 70 21/4 25 6 GS Glare Shield 57 7 6 6 178 152 152 92 23/4 31/4 83 298 3 5/8 6 15 2 SMT Stanchion Tee Mount 15 2 113/4 298 12 - 18 - 24 304 - 457 - 608 PATR4/PATS4 Pole Arm Twin Round Pole Arm Twin Square Accessories 60 89 18 15 2 23/8 3 1/2 152 YM Yoke Mount 89 24 89 95 15 2 15 2 31/2 3 1/2 304 - 457 - 608 6 210 6 152 6 15 2 153 140 127 11 3/4 113/4 5 1/2 5 165 3 3/4 95 41/5 31/4 107 83 41/8 6 152 105 41/8 105 WMSA Wall Mount TRJB Tree Mount PMSA Pole Mount FJB Flush Mount Junction Box ARJB Architectural Junction Box 47 Mounting Options Accessories KM - Knuckle Mount The 7000 Series Knuckle provides a heavy duty, self-releasing, machine tool taper allowing a continuous, lockable vertical adjustment through 180°. Rotation range is 360°. YM - Yoke Mount Heavy duty aluminum yoke is attached to body with stainless steel bolts and polymeric finish caps. Fixtures are supplied with 10 feet of 18-3 STW(U.S. Standard) cord for supply connection. ISS - Internal Source Shield Fastens to reflector mounting plate eliminating glare beyond the desired light distribution pattern. Mounting Accessories SMT - Stanchion Mount Tee PMT- Pole Mount Tee These units include a tee for mounting two fixtures. 24" (610mm) length is standard. GS - Glare Shield The formed aluminum shield, mounted in the door channel with set screws, cuts off upward glare at 35° from beam center. SMSA18 - Single. Stanchion Mount. This cast aluminum.unit includes a.base plate for surface mounting. Splice access is provided. Available in a variety of lengths, consult ordering guide. PSSA - Pedestal. Stanchion Mount Cast aluminum.unit is fitted with a.base plate for surface mounting. Splice access is provided. WMSA - Wall Mount Consists of three pieces: a mounting plate, the fixture mounting bracket, and a splice access plate. Unit mounts over a recessed wall box installation. PMSA - Pole Mount, This unit is a slipfitter for a standard 2 3/8" O.D. x 4" Tenon. Used for pole top mounting the fixture. ARJB - Architectural Junction Box Two conduit openings on bottom and one fixture mounting hole on top. Two tamper-resistant captive screws secure splice access cover. BD - Barn Doors Provide adjustable glare shielding. Each door independently mounts with set screws. PAR-Pole Arm Round PAS- Pole Arm Square Pole Mounted Arm,12,18,or 24 inches long, for existing round or square pole applications. PATR and PATS Tee Mount Arms are also available. 48 7100 SERIES – MOUNTING Mounting Options KM Knuckle Mount YM Yoke Mount WUS Wall Mount, Side Up WMS Wall Mount, Side Down FJB Flush Mount Junction Box Knuckle /Yoke TRJB Tree Mount Knuckle /Yoke Mounting Accessories PSSA Pedestal Stanchion Mount Knuckle / Yoke PMSA Pole Mount Knuckle / Yoke ARJB Architectural Junction Box Knuckle / Yoke WMSA Wall Mount Knuckle /Yoke SMSA Stanchion Mount Knuckle / Yoke PMT Pole Mount Tee Knuckle / Yoke EWM Extended Wall Mount Knuckle / Yoke SMT Stanchion Mount Tee Knuckle / Yoke PAR / PAS Pole Arm Round Pole Arm Square Knuckle / Yoke PATR / PATS Pole Arm Twin Round Pole Arm Twin Square Knuckle / Yoke 49 7100 DIMENSIONS (in inches/millimeters) Mounting Accessories Mounting Options 15 3/4 400 15 3/4 400 23/4 3 3/4 70 95 6 3 /4 6 3 /4 1 41/5 31/4 171 83 107 6 41/8 25 171 91/4 152 41/8 131/4 337 235 6 105 152 105 FJB Flush Mount Junction Box ARJB Architectural Junction Box 181/2 WMSA Wall Mount 470 KM Knuckle Mount YM Yoke Mount 31/4 83 21/4 57 61/2 5 165 127 WMS Wall Mount Side Down 131/4 337 131/4 18 3 3/4 457 95 EWM Extended Wall Mount 7 6 178 152 PMSA Pole Mount 31/2 337 6 89 24 TRJB Tree Mount 15 2 610 5 6 61/2 127 15 2 165 4 102 4 102 18 18 457 457 5 127 41/4 108 6 6 15 2 15 2 WUS Wall Mount Side Up 131/4 337 SMSA18 Stanchion Mount SMT Stanchion Mount Tee 6 15 2 6 15 2 31/ 2 24 89 610 4 3/16 7 6 1/ 2 15 3/4 10 6 178 165 400 2 51 6 15 2 4 3/16 PMT Pole Mount Tee 106 71/4 CM Ceiling Mount PSSA Pedestal Stanchion Mount 184 5 1/2 140 6 3 1/2 152 89 Accessories 4 4 13/4 102 102 45 12 - 18 - 24 304 - 457 - 608 15 3/4 15 3/4 15 3/4 400 400 400 3 5/8 92 PAR4/PAS4 Pole Arm Round Pole Arm Square 5 1/2 140 6 3 1/2 152 9 3/4 9 3/4 9 3/4 235 235 235 89 12 - 18 - 24 304 - 457 - 608 BD Barn Doors GS Glare Shield LC Polycarbonate Cover PATR4/PATS4 Pole Arm Twin Round Pole Arm Twin Square 3 5/8 92 50 7100 SERIES – MOUNTING Mounting Options KM - Knuckle Mount The 7100 Knuckle The 7100Series Series employs aprovides heavy duty, knuckle a self-releasing heavy duty,machine self tool taper allowing a releasing machine continuous, lockable a tool taper allowing vertical adjustment continuous lockable through 180°. Rotation vertical adjustment range is 360°. through 180°. Rotation range is 360°. YM - Yoke Mount A heavy duty aluminum yoke attaches to unit body by stainless steel bolts with polymeric finish caps, lock washers and nuts. Fixtures are provided with 10 feet of 18-3 STW (U.S. Standard) cord for supply connection. WMS/WUS - Fixed Wall Mount The 7100 Series Wall Mount includes a mounting plate and a factory installed splice box which hooks into the mounting plate for easy installation. It is secured by set screws and an access plate is provided on the underside. CM - Ceiling Mount A mounting splice box is attached to the unit. The fixture is secured with set screws, Mounting Accessories ARJB - Architectural Junction Box Two conduit openings on bottom and one fixture mounting hole on top. Two tamperresistant captive screws secure splice access cover. PSSA - Pedestal Stanchion Mount Two conduit openings on bottom and one fixture mounting hole on top. Two tamper-resistant captive screws secure splice access cover. WMSA - Wall Mount Consists of three pieces: a mounting plate; the fixture mounting bracket; and a splice access plate. This unit mounts over a recessed wall box and provides a clean installation. PMSA - Pole Mount, This unit is a slipfitter for a standard 2 3/8" O.D.x 4" Tenon. Used for pole top mounting of the fixture. SMSA - Single Stanchion Mount Two conduit openings on bottom and one fixture mounting hole on top. Two tamper-resistant captive screws secure splice access cover. 51 Accessories Mounting Accessories PAR- Pole Arm Round PAS- Pole Arm Square Pole Mounted Arm,12,18,or 24 inches long, for existing round or square pole applications. PATR and PATS Tee Mount (Twin) Arms are also available. GS - Glare Shield Formed aluminum shield is mounted in the door channel with set screws and cuts off upward glare at 35° from beam center. PMT - Pole Mount Tee Similar to the PM Pole Mount with a tee for mounting two fixtures. 24"(610mm) length is standard. SMT - Stanchion Mount Tee Similar to the SMSA, this unit provides a tee for mounting two fixtures. Standard length is 24" (610mm). BD - Barn Doors Provide adjustable glare shielding. Each door mounts independently with set screws. TRJB - Tree Mount This unit consists of a round splice box similar in construction to the WMSA wall mount with mounting ears. It is held to the tree by a one-inch band and turnbuckle provided by others. LC - Polycarbonate Cover This clear polycarbonate cover protects the lens from vandalism. Fitted in the door channel, affixed with set screws. 52 7200 SERIES – MOUNTING Mounting Options (250 Watt & 400 Watt products) KM Knuckle Mount YM Yoke Mount Mounting Accessories (250 Watt & 400 Watt products) TNM Tenon Mount Knuckle SMSA Stanchion Mount Knuckle / Yoke EWM Extended Wall Mount Knuckle / Yoke PMT Pole Mount Tee Knuckle / Yoke PATR / PATS Pole Arm Twin Round Pole Arm Twin Square Knuckle / Yoke PAR / PAS Pole Arm Round Pole Arm Square Knuckle / Yoke 53 Mounting Options (1000 Watt product requires SMB) KM Knuckle Mount YM Yoke Mount Mounting Accessories (1000 Watt SMB products) SMB Surface Mount Box Knuckle / Yoke Mounting Accessories (1000 Watt SMB products) SMBEWM Extended Wall Mount Knuckle / Yoke SMBR Remote Ballast (Can be used for a wide variety of mounting situations.) SMBSMSA Stanchion Mount Knuckle / Yoke SMBTNM Tenon Mount Knuckle / Yoke SMBPMT Pole Mount Tee Knuckle / Yoke SMBSMT Stanchion Mount Tee Knuckle / Yoke 54 Mounting Options (all 7200 Series products) 7200 SERIES DIMENSIONS 23 3/8 23 3/8 594 594 KM Knuckle Mount (in inches/millimeters) YM Yoke Mount 10 3/8 10 3/8 264 Mounting Accessories 264 (250 Watt & 400 Watt products) 5 14 7/16 14 7/16 126 367 367 23 101/2 584 61/2 267 TNM Tenon Mount 165 6 15 2 6 152 6 15 2 6 152 4 Accessories 102 22 22 13 /16 5 3 /8 580 137 16 3/4 2 5/8 425 67 18 559 457 252 14 10 354 113/8 289 6 6 152 15 2 SMSA18 Stanchion Mount Knuckle SMSA18 Stanchion Mount Yoke EGL External Grid Louver BD Barn Door 2213 /16 4 580 102 53 /8 580 137 10 14 4 252 354 10 2 22 13 /16 3 3/8 86 GS Glare Shield LC Lexan Cover 3 3/4 36 PMT 914 Pole Mount Tee Knuckle 95 3 3/8 Mounting Accessories (1000 Watt SMB products) 86 SMBEWM Extended Wall Mount Knuckle / Yoke 3 3/4 36 PMT 914 Pole Mount Tee Yoke 95 4 271/2 698 102 61/2 165 101/2 267 241/4 616 3 3/4 95 EWM Extended Wall Mount Knuckle 6 1/2 6 1/2 165 165 61/2 165 241/4 9 1/2 181/4 241 464 9 1/2 181/4 241 464 3 3/4 616 EWM Extended Wall Mount Yoke 95 5 1/2 140 6 3 1/2 152 89 12 - 18 - 24 304 - 457 - 608 PAR4/PAS4 Pole Arm Round Pole Arm Square 3 5/8 92 5 1/2 140 6 1/2 6 1/2 165 6 165 3 1/2 152 89 12 - 18 - 24 PATR4/PATS4 304 - 457 - 608 Pole Arm Twin Round Pole Arm Twin Square SMBTNM Tenon Mount Knuckle / Yoke 3 5/8 92 19 483 8 3/16 208 19 483 8 3/16 208 55 Mounting Accessories (1000 Watt SMB products) continued 19 483 SMBR Remote mount 6 1/2 8 3/16 165 208 6 1/2 165 8 3/16 (Can be used for a wide variety of mounting placements.) 208 19 483 8 3/16 19 6 1/2 165 208 483 SMB Knuckle SMB Yoke 6 1/2 165 6 1/2 165 22 559 SMBSMT Stanchion Tee Mount Knuckle / Yoke 22 559 6 6 15 2 15 2 38 965 8 3/16 38 208 965 9 1/2 9 1/2 241 241 9 1/2 9 1/2 241 241 8 3/16 38 208 965 SMBPMT Pole Tee Mount Knuckle / Yoke SMBSMSA Stanchion Mount Knuckle / Yoke 6 1/2 6 1/2 165 165 311/4 794 311/4 794 6 1/2 165 8 3/16 38 208 965 56 7200 SERIES – MOUNTING Mounting Options YM - Yoke Mount A heavy duty aluminum yoke attaches to body with stainless steel bolts with polymeric finish caps, lock washers and nuts. Fixtures are equipped with 10 feet of 16-3 STW (U.S. Standard) cord for supply connection. KM - Knuckle Mount The 7200 Knuckle includes an integral junction box and uses a rugged machine tool taper to lock adjustments between 0°and 180°. Rotation adjustment of 360°. Mounting Accessories EWM - Extended Wall Mount / Yoke Accepts 7200 yoke version for wall applications. TNM - Tenon Mount/Knuckle Mounts in various orientations to receive standard 7200 knuckle mount. PMT - Pole Mount Tee/Yoke Accepts two 7200 yoke mounts. 36” (914mm) length is standard, custom lengths are available. PMT - Pole Mount Tee /Knuckle Accepts two 7200 knuckle mounts. EWM - Extended Wall Mount / Knuckle Accommodates standard 7200 knuckle mount for wall applications. SMSA - Stanchion Mount This cast aluminum unit is provided with a base plate for surface mounting. Splice access plate is provided. Also available for yoke mount. PAR- Pole Arm Round PAS - Pole Arm Square Pole Mounted Arm,12,18,or 24 inches long, for existing round or square pole applications. PATR and PATS Tee Mount (Twin) Arms are also available. 57 Mounting Accessories (1000 Watt SMB product) Accessories BD - Barn Doors Provide glare shielding. Each door independently mounted by set screws. Available in custom lengths. One to four doors can be used. SMBPMT - Pole Tee Mount, Knuckle Accommodates two standard 7200 knuckle mounts with ballasts mounted in the extruded aluminum tee (1000 Watt units). SMBPMT - Pole Tee Mount, Yoke Similar to the knuckle SMBPMT above but accepts two 7200 1000 Watt yoke mounts. SMB - Mount, Knuckle Accommodates the 7200 knuckle mount with ballast mounted in the extrusion (1000 Watts). Also available for yoke mount. SMBSMSA - Stanchion Mount Extruded aluminum with splice access plate and base plate which can be custom drilled. Accepts the 7200 knuckle mount with ballast located in the extrusion (1000 Watts). Also available for yoke mount. SMBEWM - Extended Wall Mount, Knuckle Accommodates 7200 knuckle mount, ballast is located in the extrusion (1000 Watts). Also available for yoke mount. GS - Glare Shield Formed aluminum shield mounted in the door channel with set screws cuts off upward glare at 35° from beam center. EGL - External Grid Louver Door channel mounted, flat black aluminum grid cuts off glare from various viewing angles. LC - Polycarbonate Cover Clear polycarbonate cover protects the lens from vandalism. Fits in the door channel, affixed with set screws. 58 FINISH OPTIONS – STANDARD Each of the ten standard finish colors is available in its own distinctive surface texture. The particular texture associated with a particular color is indicated in these photos. Custom finishes are available. Textures of custom finishes are dependent on the finish material specified. Please consult Hydrel. DDB Dark Bronze Colors shown here are approximate, and only accurate up to the limits of the four-color printing process. DNA Natural Aluminum Aluminum fixture surfaces are four step pre-treated prior to being painted with a long-lasting TGIC polyester powder coat. BZ Bronze SND Sand BL Black STG Steel Gray WH White GN Green GR Gray TVG Terra Verde Green 59 FINISH OPTIONS – CUSTOM Custom finishes are always an option at Hydrel Fixtures and accessories can be finished to your specifications. Consult Hydrel for details and ordering information. 60 SPECIFICATIONS / ORDERING GUIDE – 7000 SERIES Description The 7000 Series Flood Light is a compact, high performance outdoor fixture accommodating lamps to 70 Watt HID. This unit is designed to provide consistent styling within Hydrel’s floodlighting systems.With a variety of distributions and mounting options, the 7000 greatly extends the uniform lighting capabilities of lower level floodlights.This fixture is fully sealed and suitable for wet locations. Features & Specifications MATERIAL: Die cast aluminum housing and door. LENS: Flat tempered glass. LAMP: Incandescent: T-4, Mini-can to 100 Watts. Fluorescent: TRT Triple Tube lamps to 42 Watts. HID: T-6, G12 to 70 Watts, E-17 medium base to 70 Watts; Elliptical, E-27 to 80 Watts. SOCKET: Incandescent: Mini-can screw base. Fluorescent: 4-Pin, GX24Q base. HID: G-12, medium, or E27 base pulse-rated 4KV. LENS: Flat tempered glass. MOUNTING: See ordering guide below, Mounting Options and Accessories on page 46, and Mounting Option chart on page 64 for comprehensive list of mounting capabilities. Knuckle Mount: Die cast aluminum with 1/2" NPT galvanized nipple. Yoke Mount: Aluminum with10' of 18-3 STW flexible cord for US standard, 3m of 3GX1.0mm HO7RN-F cable for European standard. Polymer yoke mount caps are black finish. GLARE CONTROL: Internal glare control elements. External, adjustable barn doors or fixed glare shields available. ELECTRICAL COMPONENTS: Integrally mounted ballasts rated for low temperatures. Fixtures are 100% factory tested. FINISH: See ordering guide for colors. FASTENERS: Stainless Steel. LISTING: U.L., C.U.L., CE, NEMKO. WEIGHT: 20 lbs. VOLTAGE: See ordering guide below. EPA: 0.64 LIGHT DISTRIBUTIONS: See ordering guide below. NOTE: All lamps must be rated for "Universal Burning Position" because fixture tilt changes lamp orientation. REFLECTORS: High purity anodized specular, semispecular, or patterned lighting sheet in various configurations designed to provide maximum performance and uniformity. Model Wattage & Lamp U.S. 7000 EUROPEAN Incandescent 100Q1 T4 MC NA Fluorescent 26TRT GX24Q-3 32TRT GX24Q-3 42TRT GX24Q-4 GX24Q-3 GX24Q-3 GX24Q-4 Metal Halide 50M ED17 70M ED17 35CMT6 T6 70CMT6 T6 70CM ED17 med. med. G12 G12 med. NA Ellip. T6 T6 Ellip. HPS 35S 1 50S 70S E17 E17 E17 med. NA med. E27 med. Ellip. E27 MV 50H 75H 80H E17 E17 NA med. E27 med. NA Ellip. E27 E27 G12 G12 E27 Voltage Distribution Mounting U.S. EUROPEAN 120 22050HZ 208 23050HZ 220 24050HZ 240 277 347 120/277 TB MVOLT 11 TSP 2 NHSP 2 MFL 2 FL 3 KM Knuckle Mount ARJB 4 FJB 4 YM Yoke Mount PSSA Tight Spot Nar. Hor.Spot Med. Flood Flood Mounting Acc. SMSA–––5 TRJB WMSA PMSA 1 2 3 4 5 Available in 120V only Available with T6 & T4 lamps only Available with E17 & TRT lamps only See individual spec sheet for conduit options Available in 6" increments from 12" to 48", specify length 6 Two fixtures per mounting 7 Available in 6" increments from 12" to 24", specify length 8 Available with TSP & MFL dist. only 9 Available with FL dist. only 10 Not available with NHSP 11 MVOLT is the standard voltage for fluorescent lamps 12 Options mutually exclusive PMT 6 SMT 6 EWM –––5 PAR4/–––7 PAR5/–––7 PAR6/–––7 PAS4/–––7 PAS5/–––7 PAS6/–––7 PATR4/–––6,7 PART5/–––6,7 PART6/–––6,7 PAST4/–––6,7 PAST5/–––6,7 PAST6/–––6,7 Accessories Lamp Arch. J-Box LPI Lamp Internal Included Flush Mt. J-Box ISS 8 Int. Source Shield Ped. Stan. Mt. 9 IHL Int. Honey Comb Splice Access 10 Stanchion Mount CFAMB Color Filter Amber Splice Access CFRED 10 Color Filter Red Tree Mt. J-Box CFBLU 10 Color Filter Blue Wall Mount CFGRN 10 Color Filter Green Splice Access External 12 Pole Mount Splice Access BD Barn Doors Pole Mount Tee GS Glare Shield Stan. Mount Tee Ext. Wall Mount Pole Arm Round,4" dia. Pole Arm Round,5" dia. Pole Arm Round,6" dia., Pole Arm Square,4" sq. Pole Arm Square,5" sq. Pole Arm Square,6" sq. Pole Arm Twin Round,4" dia. Pole Arm Twin Round,5" dia. Pole Arm Twin Round,6" dia. Pole Arm Twin Square,4" sq. Pole Arm Twin Square,5" sq. Pole Arm Twin Square,6" sq. Finish BL BZ DDB DNA GN GR SND STG TVG WH CF Listing Black IEC International Electrotechnical Bronze Commission Dark Bronze Natural Alum. Green Gray Sand Steel Gray Terra Verde Green White Custom U.L. and C.U.L. Listed for wet locations. NEMKO CE N IP 65 Rating Hydrel is an ISO9001 Certified Manufacturer 61 SPECIFICATIONS / ORDERING GUIDE – 7100 SERIES Description The 7100 Series Flood Light is a compact, high performance outdoor fixture accommodating lamps to 175 Watt HID. This unit is designed to provide consistent styling within Hydrel’s floodlighting systems. With a wide variety of vertical and horizontal light distributions, and mounting options, the 7100 greatly extends the uniform lighting capabilities of lower to mid-level floodlights. This fixture is fully sealed and suitable for wet locations. Features & Specifications MATERIAL: Die cast aluminum housing and door. LAMP: Incandescent: T-3, RSC Quartz to 500 Watts, T-4, Minican to 250 Watts. HID: T-6, G12 to 150 Watts, E-17 medium base to 175 Watts; Elliptical, E-27 to 150 Watts. See ordering guide for further lamp options. LENS: Flat tempered glass. MOUNTING: See ordering guide below, Mounting Options and Accessories on page 48, and Mounting Option chart on page 64 for comprehensive list of mounting capabilities. Knuckle or yoke mounted (180° vertical, 360° rotation); Fixed mounted for ceiling or wall. Knuckle Mount: Die cast aluminum with 3/4" NPT galvanized nipple standard. Yoke Mount: Aluminum with 10' of 18-3 STW flexible cord for US standard, 3m of 3GX1.0mm HO7RN-F cable for European standard. Polymer yoke mount caps are black finish. GLARE CONTROL: Internal glare control elements, external adjustable barn doors or fixed glare shields available. ELECTRICAL COMPONENTS: Integrally mounted ballasts rated for low starting temp. Fixtures are 100% factory tested. SOCKET: Incandescent: Recessed Single Contact (RSC), Minican screw base. HID: G-12, medium, or E27 base pulse-rated 4KV. See ordering guide below for further lamp options. FINISH: See ordering guide below for colors. VOLTAGE: See ordering guide below. WEIGHT: 37 lbs. LIGHT DISTRIBUTION: See ordering guide below. EPA: 1.27 REFLECTORS: High purity anodized specular, semi-specular, patterned lighting sheet in various configurations designed to provide maximum performance and uniformity. NOTE: All lamps must be rated for “Universal Burning Position” because fixture tilt changes lamp orientation. Model Wattage & Lamp U.S. 7100 Incandescent 250Q T4 250QB NA 300Q T3 300QB NA 400Q T4 500Q T3 300TH NA Metal Halide 70M ED17 70CM ED17 100M ED17 100CM ED17 150M ED17 175M ED17 70CMT6 T6 150CMT6 T6 70HQI T6 70CMTD T6 150HQI T7 150CMTD T7 EUROPEAN MC NA Tub. BA15d RSC NA Tub. BA15d MC NA MC NA Tub. RX7 med. med. med. med. med. med. G12 G12 RSC RSC RSC RSC Ellip. Ellip. Ellip. Ellip. Ellip. NA T6 T6 Tub. T6 Tub. T7 FASTENERS: Stainless steel LISTING: U.L., C.U.L., CE, NEMKO Voltage Distribution Mounting Mounting Acc. U.S. EUROPEAN 120 22050HZ 208 23050HZ 220 24050HZ 240 277 347 120/277 480 TB NSP 1 NHSP SP HSP HFL 2 VFL WFL KM Knuckle Mount YM Yoke Mount 3 CM Ceiling Mount WMS 3 Wall Mount Side WUS 3 Wall Mount Side up ARJB 4 FJB 4 PSSA Nar. Spot Nar. Hor. Spot Spot Hor. Spot Hor. Flood Vert. Flood Wide Flood HPS 70S 100S 150S E17 E17 E17 med. Ellip. E27 med. NA med. NA MV 75H 80H 100H 125H E17 NA E17 NA med. NA Ellip. E27 med. NA Ellip. E27 TRJB WMSA PMSA E27 E27 E27 E27 E27 G12 G12 RX7 RX7 RX7 RX7 SMSA–––5 1 2 3 4 5 6 7 8 9 10 11 12 13 Available with 70CMT6, and 150CMT6 lamps only Not available with RSC or R75 base lamps Not available with mounting accessories See individual spec sheet for conduit options Available in 6" increments from 12" to 48",specify length Two fixtures per mounting Available in 6" increments from 12" to 24", specify length Not available with VFL or WFL distributions Options mutually exclusive Not available with CM mounting Available with 120V or 277V only Available with 208V, 240V, or 347V only Not available with 480Volts, NSP, and HSP distribution PMT 6 SMT 6 EWM –––5 PAR4/–––7 PAR5/–––7 PAR6/–––7 PAS4/–––7 PAS5/–––7 PAS6/–––7 PATR4/–––6,7 PART5/–––6,7 PART6/–––6,7 PAST4/–––6,7 PAST5/–––6,7 PAST6/–––6,7 Accessories Arch. J-Box Internal Flush J-Box ISS 8 Int. Source Shield Ped. Stan. Mt. 7" CFAMB Color Filter Amber Splice Access CFRED Color Filter Red Stanchion Mount CFBLU Color Filter Blue Splice Access Tree Mt. J-Box CFGRN Color Filter Green Wall Mount External 9 Splice Access BD Barn Doors Pole Mount GS 10 Glare Shield Splice Access LC 10 Polycarbonate Pole Mount Tee Cover Stan. Mount Tee Ext. Wall Mount Pole Arm Round,4" dia., Pole Arm Round,5" dia., Pole Arm Round,6" dia., Pole Arm Square,4" sq. Pole Arm Square,5" sq. Pole Arm Square,6" sq. Pole Arm Twin Round,4" dia. Pole Arm Twin Round,5" dia. Pole Arm Twin Round,6" dia. Pole Arm Twin Square,4" sq. Pole Arm Twin Square,5" sq. Pole Arm Twin Square,6" sq. Options Finish Fusing SF 11 Single Fuse DF 12 Double Fuse Photo Control Photo Cell PE Re-Strike QRS12,13 Quartz Emergency Re-Strike BL BZ DDB DNA GN GR SND STG TVG WH CF Lamp LPI Lamp Included U.L. and C.U.L. Listed for wet locations. NEMKO CE N IP 65 Rating Hydrel is an ISO9001 Certified Manufacturer Listing Black IEC International Electrotechnical Bronze Dark Bronze Commission Natural Alum. Green Gray Sand Steel Gray Terra Verde Green White Custom 62 SPECIFICATIONS / ORDERING GUIDE – 7200 SERIES 400 WATT Description The 7200 Series of outdoor lighting fixtures is designed to provide consistent styling with a variety of light distributions. Styling is consistent with the smaller companion 7000 and 7100 Series units. Multiple optical systems achieve a wide variety of vertical and horizontal light distributions, from tight spots to wide floods. A variety of mounting orientations are available including wall, stanchion, base, knuckle, yoke, and pole mounts. Features & Specifications LENS: Flat tempered glass. MOUNTING: See ordering guide below, Mounting Options and Accessories on page 52, and Mounting Option chart on page 64 for comprehensive list of mounting capabilities. Fixtures can be knuckle or yoke mounted (180° vertical, 360° rotation) on pole, stanchion, wall, or tenons. All mounting accessories are aluminum, secured with stainless steel fasteners. GLARE CONTROL: Internal glare control elements, external adjustable barn doors or fixed glare shields available. MATERIAL: Die cast aluminum housing and door. LAMP: HID to 400 Watts. ELECTRICAL COMPONENTS: Integrally mounted ballasts rated for low starting temp. Fixtures are 100% factory tested. SOCKET: Porcelain mogul base rated 5KV. FINISH: See ordering guide for colors. VOLTAGE: See ordering guide below. FASTENERS: Stainless Steel LIGHT DISTRIBUTION: See ordering guide below. LISTING: U.L., C.U.L., C.E., NEMKO REFLECTORS: High purity anodized specular, semi-specular, or patterned lighting sheet in various configurations to provide optimum optical performance. Reflectors are interchangeable using four screws and quick-release electrical connectors (with the exception of spot reflectors.) Reflectors include both segmented and hydroformed types to provide maximum performance and uniformity. Model Wattage & Lamp U.S. 7200 Metal Halide 200M 1,2 ED28 250M ED28 320M1 ED28 1,2 350M ED28 400M ED37 HPS 250S 400S Voltage EUROPEAN mog. mog. mog. mog. mog. E90 or Ellip. E40 E90 or Ellip. E40 E90 or Ellip. E40 E90 or Ellip. E40 E120 or Ellip. E40 ED18 mog. Ellip. or Tub. E40 ED18 mog. Ellip. or Tub. E40 Distribution Mounting WEIGHT: 50 lbs. EPA: 3.00 NOTE: All lamps must be rated for “Universal Burning Position” because fixture tilt changes lamp orientation. Accessories Internal Spot KM Knuckle Mount ISS 5 Int. Source Shield Hor. Spot YM Yoke Mount CFAMB Color Filter Amber Narrow Hor. Spot CFRED Color Filter Red Hor. Flood Mounting Acc. CFBLU Color Filter Blue Vert. Flood 13 CFGRN Color Filter Green Wide Flood EWM––– Extended Wall Mount PSSA Ped. Stan. Mt. 7" External 14 Splice Access BD Barn Doors SMSA–––12 Stanchion Mount GS Glare Shield Splice Access LC Polycarbonate Cover 3 TNM Tenon Mount 6 EGL Ext. Grid Louver SMT 4 Stanchion Mount Tee 4 PMT Pole Mount Tee PAR4/–––15 Pole Arm Round,4" dia. PAR5/–––15 Pole Arm Round,5" dia. PAR6/–––15 Pole Arm Round,6" dia. 1 Available only with SCWA ballast PAS4/–––15 Pole Arm Square,4" sq. 2 200M and 350M are not available with SP distribution PAS5/–––15 Pole Arm Square,5" sq. 3 For use with KM only PAS6/–––15 Pole Arm Square,6" sq. 4 Two fixtures per mounting PATR4/–––4,15 Pole Arm Twin Round,4" dia. 5 Not available with WFL distribution PART5/–––4,15 Pole Arm Twin Round,5" dia. 6 EGL accessory available in flat black finish only PART6/–––4,15 Pole Arm Twin Round,6" dia. 7 Available with 120V or 277V only PAST4/–––4,15 Pole Arm Twin Square,4" sq. 8 Available with 208V, 240V, or 347V only PAST5/–––4,15 Pole Arm Twin Square,5" sq. 9 Not available with 480V, TBV, or NHSP PAST6/–––4,15 Pole Arm Twin Square,6" sq. 10 U.S. EUROPEAN 120 22050HZ 208 23050HZ 220 24050HZ 240 277 347 480 120/277 TB TBV SP HSP NHSP HFL VFL WFL Available only with 250M or 400M 11 Available only with 200M, 250M, 320M, 350M,or 400M 12 Available in 6" increments from 12" - 48" - specify length 13 Available in 6" increments from 18" - 36" - specify length 14 Options mutually exclusive 15 Available in 6" increments from 12" to 24"- specify length Options Lamp Fusing LPI Lamp Included Single Fuse SF 7 DF 8 Double Fuse Photo Control Photo Cell PER Re-Strike 9 Quartz QRS Emergency Re-Strike Ballasting 10 Constant Wattage CWA Ballast SCWA11 Super CWA Pulse Start Finish U.L. and C.U.L. Listed for wet locations. NEMKO CE N IP 65 Rating Hydrel is an ISO9001 Certified Manufacturer Listing BL Black IEC International Electrotechnical BZ Bronze DDB Dark Bronze Commission DNA Natural Alum. GN Green GR Gray SND Sand STG Steel Gray TVG Terra Verde Green WH White CF Custom Form No. 106.20 8 / 04 12881 Bradley Avenue, Sylmar, CA 91342 T 818.362.9465 F 818.362.6548 Email: custserv@hydrel.com www.hydrel.com ©2004 Acuity Brands Inc. All rights reserved. “Hydrel” is a trademark of Acuity Brands Inc. 63 SPECIFICATIONS / ORDERING GUIDE – 7200 SERIES 1000 WATT Description The 7200 Series Architectural Lighting System is a series of outdoor fixtures designed to provide consistent styling with a wide variety of vertical and horizontal light distributions. These luminaires greatly extend the uniform lighting capabilities for low level floodlights. Multiple optical systems achieve a wide variety of vertical and horizontal light distributions, from horizontal spot to vertical floods. There are also a variety of mounting options available including wall, stanchion, base, knuckle and yoke mounts. Fixture is fully sealed with silicone gasketing, suitable for wet location. LENS: Flat tempered glass. MOUNTING: See ordering guide below. Mounting Options and Accessories on page 53, and Mounting Option chart on page 64 for comprehensive list of mounting capabilities. Fixtures can be knuckle or yoke mounted (180° vertical, 360° rotation) on pole, stanchion, wall, or tenons. All mounting accessories are aluminum, secured with stainless steel fasteners. GLARE CONTROL: Internal glare control elements, external adjustable barn doors or fixed glare shields available. Features & Specifications ELECTRICAL COMPONENTS: Externally mounted ballasts. MATERIAL: Die cast aluminum housing and door. FINISH: See ordering guide. LAMP: HID to 1000 Watts FASTENERS: Stainless steel. SOCKET: Porcelain mogul base rated 5 KV. LISTING: U.L., C.U.L. VOLTAGE: See ordering guide below. WEIGHT: 40 lbs. (head only) LIGHT DISTRIBUTION: See ordering guide below. EPA: 3.00 REFLECTORS: High purity anodized specular, semi-specular, or patterned lighting sheet in various configurations to provide optimum optical performance. Reflectors are interchangeable using four screws and quick-release electrical connectors (with the exception of spot reflectors). Reflectors include both segmented and hydroformed types to provide maximum performance and uniformity. NOTE: All lamps must be rated for “Universal Burning Position” because fixture tilt changes lamp orientation. Model Wattage & Lamp Voltage Distribution Mounting Mounting Acc. Accessories 7200 Metal Halide 1000M Reduced envelope BT-37 1000S Reduced envelope ED-37 U.S. EUROPEAN 120 22050HZ 208 23050HZ 220 24050HZ 240 277 347 480 120/277 TB TBV SP Spot HSP Hor. Spot NHSP Narrow Hor. Spot HFL Hor. Flood VFL Vert. Flood WFL Wide Flood KM Knuckle Mount YM Yoke Mount SMB SMBEWM SMBPMT 1 SMBSMSA SMBSMT 1 SMBTNM 2 Fusing Internal ISS 3 Int. Source Shield SF 5 Single Fuse DF 6 Double Fuse External 4 Photo Control BD Barn Doors PER Photo Cell GS Glare Shield EGL Ext. Grid Louver Re-Strike QRS 7 Quartz Emergency Re-Strike Ballasting 8 CWA 1 2 3 4 5 6 7 8 Two fixtures per mounting For use with KM only Not available with WFL distribution Options mutually exclusive Available with 120V or 277V only Available with 208V, 240V, or 347V only Not available with 480V, TBV, or NHSP distribution Available with 1000M only Surface Mounted Ballast SMB Extended Wall Mount Pole Mount Tee SMB Stanchion Mount SMB Stanchion Mount Tee SMB Tenon Mount Options Lamp Finish LPI Lamp Included BL Black IEC International Electrotechnical BZ Bronze DDB Dark Bronze Commission DNA Natural Alum. GN Green GR Gray SND Sand STG Steel Gray TVG Terra Verde Green WH White CF Custom U.L. and C.U.L. Listed for wet locations. NEMKO CE N IP 65 Rating Hydrel is an ISO9001 Certified Manufacturer Listing 64 MOUNTING OPTIONS * * * * * * No Mo unt ing AR Ac JB ces Arc sor hite FJ ies B ctu Ava Flu ral s ilab h Jun PM J le u ctio SA nct ion nB Po ox le M Bo PM x T oun Po t le M SM o SA unt Tee Sta PS nch SA ion Pe Mo des SM unt tal T Sta Sta n n c WM chi hio on n M SA Mo Wa oun unt TR l l t Mo JB Tee unt Tre eM EW oun M Ext t Ju end TN nct M ion ed Ten Wa Bo ll M x on PA Mo oun RP unt t ole Arm PA SP Ro ole und Arm PA TR S qu Po are le A PA rm TS Tw Po in R le A SM oun rm BS d Tw MB in S SM Mo q uar BE unt e WM SM SM BS B MS Ext AS SM end MB BS ed MT Wa Sta ll M SM SM nch oun BS BP ion tan MT t Mo chi SM SM unt on BP BT T e NM eM ole oun SM Tee SM BR t BT Mo eno unt SM nM BR oun em ote t Mo unt MOUNTING ACCESSORIES MOUNTING OPTIONS 7000 Series 26 Watt to 70 Watt ADJUSTABLE Knuckle Mount KNUCKLE Yoke Mount 7100 Series YOKE * ●* ●* ●* ● ● ● ● ● ● ● ● ● ● ● ● ● * * ● ● ● ● ● ● * ●* ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● * * ● ● ● ● ● ● * ●* ● ● ● ● ● ● ● ● ● ● ● ● ● ● * ●* ● ● ● ● 50 Watt to 175 Watt ADJUSTABLE Knuckle Mount Yoke Mount KNUCKLE YOKE * ●* ●* ●* FIXED Wall Mount Side down/up Ceiling Mount 7200 Series WMS / WUS ● CM ● 400 Watt ADJUSTABLE Knuckle Mount Yoke Mount 7200 Series KNUCKLE YOKE * * ● * ●* ●* ●* ● ● ● 1000 Watt ADJUSTABLE Knuckle Mount Yoke Mount KNUCKLE ● ● ● YOKE ● ● ● * ● Two fixtures per mounting * * ●* ●* ● ● ● ● ● ● 65 Protected Performance Lighting an American landmark with Hydrel Series 7200 luminaires. A project to update the lighting at Hoover Dam resulted in replacing sixtyfour HPS fixtures with thirty-two 1000 Watt Metal Halide Series 7200 units using a combination of flood and spot distributions. Uniformity and color rendering improved dramatically, while operating costs dropped by 23%. The sturdy 7200s were chosen for their performance and rugged construction. The units are knuckle mounted on remote ballast enclosures to provide easy adjustment. 7200 MH 1000 spot and flood fixtures on surface mounted ballast enclosures aimed for maximum impact on the face of the dam.