Fuse switch-disconnectors FUSE SWITCH-DISCONNECTORS LTL4a SIZE 4a UP TO 1600 A Fuse switch-disconnector LTL4a is intended for fuse-links with blade contacts size 4a. It enables safe disconnection of rated current and overcurrent according to utilization category and operating voltage. Basic part is made of glass reinforced polyester. The material is resistant both to mechanical load and high temperature. Transparent cover is made of self-extinguishing polycarbonate, and contains a mechanical interlock, which protects the cover against undesirable opening by dynamic forces arising at short-circuiting. High breaking capacity. Fuse switch-disconnector 1250 and 1600 A Product code In [A] Version Connection Weight [kg] Packing [pcs] LTL4a-1x/1250/8 08213 1250 1-pole 1 x M16 5.600 1 LTL4a-1x/1600/8 14806 1600 1-pole 2 x M12 5.800 1 LTL4a-3x/1250/8 08211 1250 1 x M16 16.800 1 LTL4a-3x/1600/8 08714 1600 2 x M12 17.300 1 LTL4a-3x3/1250/8 07886 1250 1 x M16 17.700 1 LTL4a-3x3/1600/8 08212 1600 2 x M12 18.200 1 Type 3-pole, 1-pole controlled 3-pole, 1-pole controlled 3-pole, 3-pole controlled 3-pole, 3-pole controlled E33 Fuse switch-disconnectors FUSE SWITCHDISCONNECTORS LTL4a SIZE 4a UP TO 1600 A Accessories Description Front cover position signalling, for LLT4a-3x... at closing, contacts 1 and 4 are closed (see the diagram for connection), in case of 3-pole control, it is installed in the central pole. For 1-pole control, the signalling is installed in each pole. Type EMV-LTL4a Special active contacts Q enable safe handling the fuse switch-disconnectors under extreme conditions. It prevents the blade contacts getting in an intermediate position between “MAKE” and “BREAK” positions. It allows load …/Q disconnection in any state of the current circuit. (In order add “…/Q” after the type reference.) E34 Product code Weight [kg] Packing [pcs] 10423 0.005 1 - 0.010 1 Fuse switch-disconnectors FUSE SWITCHDISCONNECTORS LTL4a SIZE 4a UP TO 1600 A Parameters Type Rated operating voltage Ue Rated operating current Ie LTL4a…1250A LTL4a…1600A 690 V 690 V 1250 A 500 V a.c. 690 V a.c. Utilization category Ith Thermal current with disconnecting link Rated frequency Rated insulation voltage Ith fn Ui Rated conditional short-circuit current (rms) Icc 400 V a.c. 500 V a.c. 7500 A 3750 A 1875 A 1250 A 1250 A/500 V a.c. 1000 A/690 V a.c. 1250 A 40 ÷ 60 Hz 750 V a.c. Rated making and breaking capacity Thermal current with fuse-link 1600 A AC-22B AC-21B 400 V a.c., cos φ = 0,35 500 V a.c., cos φ = 0,35 690 V a.c., cos φ = 0,35 220 V d.c., L/R = 15 ms 400 V a.c. 500 V a.c. 690 V a.c. Rated impulse withstand voltage Uimp Rated short-time withstand current Icw 1 s Fuse-link size Max. power losses of the fuse-link Pv Pv Power losses at Ith without fuse-link Electrical durability operating cycles Mechanical durability operating cycles Degree of protection from the front side, built-in device, cover closed (without measuring holes broken off ) Degree of protection from the front side, built-in device, cover open or removed Operating ambient temperature Altitude above sea level max. Pollution degree Overvoltage category for 690 V a.c. Seismic resistance per VE ŠKODA Torque 7500 A 3750 A 1875 A 1600 A 1600 A/500 V a.c. 1000 A/690 V a.c. 1600 A 40 ÷ 60 Hz 750 V a.c. 120 kA 80 kA 50 kA 8 kV Standards AC-21B AC-21B 4a 110 W 67 W 200 1000 8 kV 30 kA 4a 164 W 67 W 200 1000 IP 20 IP 20 IP 20 IP 20 - 25÷ + 55 °C 2000 m 3 III 3 g/8 ÷ 50 Hz 50 ÷ 60 Nm IEC 60947-1, -3 EN 60947-1, -3 - 25 ÷ + 55 °C 2000 m 3 III 3 g/8 ÷ 50 Hz 30 ÷ 45 Nm IEC 60947-1, -3 EN 60947-1, -3 Approval marks EN 60947-3 ed. 2/A2, p. C.5 Instructions for the use of 1-pole controlled devices states: These devices are intended for distribution systems with possible necessity of switching and/or safe disconnection of individual phases, and must not be used for switching a primary circuit of a three-phase equipment. Dimensions 217.5 108 301 324 332 108 270 205 26 85 108 116 6 185 115 EMV-LTL4a 338.5 350 346 338.5 350 346 80 312 339 96 M16 x 60 40 13 154.5 445 E35 Fuse switch-disconnectors FUSE SWITCHDISCONNECTORS LTL4a SIZE 4a UP TO 1600 A Dimensions Drilling plans Terminals switch-disconnectors 1 – pole 3 – pole 45 7 7 1 – pole 172.5 328 328 3 – pole 325 109 Remote signalling of cover position of 1-pole and 3-pole switch-disconnectors State of contacts with closed cover: contacts 1 – 4 closed 1 4 2 E36 5 A/250 V a.c. 0.2 A/250 V d.c. 22 22 18 Clearance 14 25 250 14 22.5 216 9 13 67 25 55 25 30 25 30 13 45 9 50 50 In = 1250A In = 1600A