VZ-DC24-320

advertisement
VZ-DC24-320
OUTPUT 24V DC / 320W POWER TRANSFORMER
VZ-DC24-320 FEATURES & HIGHLIGHTS
• AC Input - 88 ~ 264V AC (124 ~ 370V DC), 47 ~ 63Hz
• DC Output - 24V DC / 320 W
• Built-in Active PFC function, Power Factor > 0.95
• A Low Profile Enclosed Power Supply with PFC Function
• Over Voltage / Overload / Over current / Short-Circuit Protection
• 30mm Low Profile Design for 1U Installation
• Conformal Coating and Green LED per Output
• UL/CUS listed
0.45” / 11.5 mm
Designed specifically for ViewZ public view monitor model:
2.55” / 65 mm
DIMENSIONS
19
/ø
74
”
/ø
0.98” / 25 mm
Over voltage
Type
Over temperature
105 ~ 135% rated output power
Hiccup mode, recovers automatically
after fault condition is removed
27.6 ~ 32.4V
Shut down o/p voltage, Power Recovery
Shut down o/p voltage, Recovers
automatically after temperature goes down
2.5” / 63.5 mm
6.29” / 160 mm
DIMENSIONS & WEIGHT
8.26” / 210 mm
Net Dimensions ( Width x Height x Length ) 8.26” x 13.38” x 3.34” / 210 x 340 x 85 mm
Gross Dimensions
11.75” x 17.5” x 7” / 298.45 x 444.5 x 177.8 mm
Net Weight / Gross Weight
8.2 lbs (3.7 kg) / 9.7 lbs (4.4 kg)
Regulations SAFETY STANDARDS
Operating Humidity
Storage Humidity
Operating Temperature
Storage Temperature
Temperature Coefficient
Vibration
MTBF.
”
1.96” / 50 mm
PROTECTION
13.38” / 340 mm
Type
88 ~ 264V AC / 124 ~ 370V DC, 47 ~ 63 Hz
DC 24V / 321.6 W
20 ~ 26.4V
13.4 A / 0 ~ 13.4A
5” / 127 mm
Overload
VZ-DC24-320
1.5” / 38 mm
Input Voltage
Output Voltage
Output Voltage Adjustment Range
Total Output Current / Range
FEATURES
0.157” / 4 mm
MODEL #
50mm
ø
0.
74
0.
5.23” / 133 mm
ø
1.18” / 30 mm
m
19
m
m
m
0.62” / 16 mm
2.55” / 65 mm
3.34” / 85 mm
GENERAL
UL/CUL
20 ~ 90% RH. Non-condensing
10 ~ 95% RH. Non-condensing
-22°F ~ 158°F / -30°C ~ +70°C
-40°F ~ 185°F / -40°C ~ +85°C
±0.03%/°C ( 0°C ~ 50°C )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
206.5K hrs min. MIL-HDBK-217F (25°C)
Contact ViewZ
•Address : 177 W. Orangethorpe Ave., Placentia, CA 92870
•Phone : (714) 996-1177, Fax : (714) 996-1138
•Sales : sales@viewzusa.com
•Specification subject to change without notice.
VZ-DC24-320
OUTPUT 24V DC / 320W POWER TRANSFORMER
MECHANICAL SPECIFICATION
215
32.5
150
36. 7
LED
+V
ADJ.
9
4-M4 L=4mm
7
50
5
47.45
32.5
150
3
2
32. 5
6.5
16
30
1
12. 5
2
6.9
89
4
12. 8
135
6
115
.5
8
6.5
Air flow
dire ction
4-M4 (Bot h Side s) L=5 mm
15
RECOMMENDED OPERATION DISTANCE
*18AWG is highly recommended to ensure operation distance as shown in the charts
23” PVMZ & iPVMZ - 3 MONITORS - VZ-PVM-Z2B3, Z2W3, I2B3 & I2W3
Cable Type - 18AWG (Current : 12~19 A)
ft / meter
100 ft / 30.48 m
150 ft / 45.72 m
200 ft / 60.96 m
250 ft / 76.20 m
300 ft / 91.44 m
350 ft / 106.68 m
1 Set of PVMZ / iPVMZ
DC 24V
tested
tested
tested
tested
DC 27V
tested
tested
tested
tested
tested
Max. V
tested
tested
tested
tested
tested
tested
2 Set of PVMZ / iPVMZ
DC 24V
tested
tested
tested
tested
DC 27V
tested
tested
tested
tested
tested
Max. V
tested
tested
tested
tested
tested
tested
27” PVMZ & iPVMZ - 3 MONITORS - VZ-PVM-Z3B3, Z3W3, I3B3 & I3W3
Cable Type - 18AWG (Current : 12~19 A)
ft / meter
100 ft / 30.48 m
150 ft / 45.72 m
200 ft / 60.96 m
250 ft / 76.20 m
300 ft / 91.44 m
350 ft / 106.68 m
1 Set of PVMZ / iPVMZ
DC 24V
tested
tested
tested
DC 27V
tested
tested
tested
tested
Max. V
tested
tested
tested
tested
2 Set of PVMZ / iPVMZ
DC 24V
tested
tested
tested
DC 27V
tested
tested
tested
tested
Max. V
tested
tested
tested
tested
DC 24V
tested
tested
tested
tested
DC 27V
tested
tested
tested
tested
tested
Max. V
tested
tested
tested
tested
tested
tested
Input : Power Source output terminal
Output : Set input terminal
3 Set of PVMZ / iPVMZ
DC 24V
tested
tested
tested
DC 27V
tested
tested
tested
tested
Max. V
tested
tested
tested
tested
Not Recommended
32” PVMZ & iPVMZ - 3 MONITORS - VZ-PVM-Z4B3, Z4W3, I4B3 & I4W3
Cable Type - 18AWG (Current : 12~19 A)
ft / meter
100 ft / 30.48 m
150 ft / 45.72 m
200 ft / 60.96 m
250 ft / 76.20 m
300 ft / 91.44 m
350 ft / 106.68 m
3 Set of PVMZ / iPVMZ
1 Set of PVMZ / iPVMZ
DC 24V
tested
tested
DC 27V
tested
tested
tested
Max. V
tested
tested
tested
2 Set of PVMZ / iPVMZ
DC 24V
tested
tested
PRECAUTIONS
and service should be performed only by qualified service personnel
h Installation
and should conform to all local codes.
reduce the risk of electric shock or fire, do not expose this equipment to rain or h Tomoisture.
h Always connect ground first and remove last
This equipment shall be installed in a manner which prevents unintentional
operation by employees, cleaning crew, or others working in the premises.
To prevent faulty operation, ensure that all wiring is routed and secured to prevent
accidental open or short-circuit conditions.
This equipment is not intended for use within the patient care areas of a health
care facility.
DC 27V
tested
tested
tested
Max. V
tested
tested
tested
3 Set of PVMZ / iPVMZ
DC 24V
tested
tested
DC 27V
tested
tested
tested
Max. V
tested
tested
tested
Not Recommended
Contact ViewZ