VZ-DC24-320 OUTPUT 24V DC / 320W POWER TRANSFORMER VZ-DC24-320 FEATURES & HIGHLIGHTS • AC Input - 88 ~ 264V AC (124 ~ 370V DC), 47 ~ 63Hz • DC Output - 24V DC / 320 W • Built-in Active PFC function, Power Factor > 0.95 • A Low Profile Enclosed Power Supply with PFC Function • Over Voltage / Overload / Over current / Short-Circuit Protection • 30mm Low Profile Design for 1U Installation • Conformal Coating and Green LED per Output • UL/CUS listed 0.45” / 11.5 mm Designed specifically for ViewZ public view monitor model: 2.55” / 65 mm DIMENSIONS 19 /ø 74 ” /ø 0.98” / 25 mm Over voltage Type Over temperature 105 ~ 135% rated output power Hiccup mode, recovers automatically after fault condition is removed 27.6 ~ 32.4V Shut down o/p voltage, Power Recovery Shut down o/p voltage, Recovers automatically after temperature goes down 2.5” / 63.5 mm 6.29” / 160 mm DIMENSIONS & WEIGHT 8.26” / 210 mm Net Dimensions ( Width x Height x Length ) 8.26” x 13.38” x 3.34” / 210 x 340 x 85 mm Gross Dimensions 11.75” x 17.5” x 7” / 298.45 x 444.5 x 177.8 mm Net Weight / Gross Weight 8.2 lbs (3.7 kg) / 9.7 lbs (4.4 kg) Regulations SAFETY STANDARDS Operating Humidity Storage Humidity Operating Temperature Storage Temperature Temperature Coefficient Vibration MTBF. ” 1.96” / 50 mm PROTECTION 13.38” / 340 mm Type 88 ~ 264V AC / 124 ~ 370V DC, 47 ~ 63 Hz DC 24V / 321.6 W 20 ~ 26.4V 13.4 A / 0 ~ 13.4A 5” / 127 mm Overload VZ-DC24-320 1.5” / 38 mm Input Voltage Output Voltage Output Voltage Adjustment Range Total Output Current / Range FEATURES 0.157” / 4 mm MODEL # 50mm ø 0. 74 0. 5.23” / 133 mm ø 1.18” / 30 mm m 19 m m m 0.62” / 16 mm 2.55” / 65 mm 3.34” / 85 mm GENERAL UL/CUL 20 ~ 90% RH. Non-condensing 10 ~ 95% RH. Non-condensing -22°F ~ 158°F / -30°C ~ +70°C -40°F ~ 185°F / -40°C ~ +85°C ±0.03%/°C ( 0°C ~ 50°C ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes 206.5K hrs min. MIL-HDBK-217F (25°C) Contact ViewZ •Address : 177 W. Orangethorpe Ave., Placentia, CA 92870 •Phone : (714) 996-1177, Fax : (714) 996-1138 •Sales : sales@viewzusa.com •Specification subject to change without notice. VZ-DC24-320 OUTPUT 24V DC / 320W POWER TRANSFORMER MECHANICAL SPECIFICATION 215 32.5 150 36. 7 LED +V ADJ. 9 4-M4 L=4mm 7 50 5 47.45 32.5 150 3 2 32. 5 6.5 16 30 1 12. 5 2 6.9 89 4 12. 8 135 6 115 .5 8 6.5 Air flow dire ction 4-M4 (Bot h Side s) L=5 mm 15 RECOMMENDED OPERATION DISTANCE *18AWG is highly recommended to ensure operation distance as shown in the charts 23” PVMZ & iPVMZ - 3 MONITORS - VZ-PVM-Z2B3, Z2W3, I2B3 & I2W3 Cable Type - 18AWG (Current : 12~19 A) ft / meter 100 ft / 30.48 m 150 ft / 45.72 m 200 ft / 60.96 m 250 ft / 76.20 m 300 ft / 91.44 m 350 ft / 106.68 m 1 Set of PVMZ / iPVMZ DC 24V tested tested tested tested DC 27V tested tested tested tested tested Max. V tested tested tested tested tested tested 2 Set of PVMZ / iPVMZ DC 24V tested tested tested tested DC 27V tested tested tested tested tested Max. V tested tested tested tested tested tested 27” PVMZ & iPVMZ - 3 MONITORS - VZ-PVM-Z3B3, Z3W3, I3B3 & I3W3 Cable Type - 18AWG (Current : 12~19 A) ft / meter 100 ft / 30.48 m 150 ft / 45.72 m 200 ft / 60.96 m 250 ft / 76.20 m 300 ft / 91.44 m 350 ft / 106.68 m 1 Set of PVMZ / iPVMZ DC 24V tested tested tested DC 27V tested tested tested tested Max. V tested tested tested tested 2 Set of PVMZ / iPVMZ DC 24V tested tested tested DC 27V tested tested tested tested Max. V tested tested tested tested DC 24V tested tested tested tested DC 27V tested tested tested tested tested Max. V tested tested tested tested tested tested Input : Power Source output terminal Output : Set input terminal 3 Set of PVMZ / iPVMZ DC 24V tested tested tested DC 27V tested tested tested tested Max. V tested tested tested tested Not Recommended 32” PVMZ & iPVMZ - 3 MONITORS - VZ-PVM-Z4B3, Z4W3, I4B3 & I4W3 Cable Type - 18AWG (Current : 12~19 A) ft / meter 100 ft / 30.48 m 150 ft / 45.72 m 200 ft / 60.96 m 250 ft / 76.20 m 300 ft / 91.44 m 350 ft / 106.68 m 3 Set of PVMZ / iPVMZ 1 Set of PVMZ / iPVMZ DC 24V tested tested DC 27V tested tested tested Max. V tested tested tested 2 Set of PVMZ / iPVMZ DC 24V tested tested PRECAUTIONS and service should be performed only by qualified service personnel h Installation and should conform to all local codes. reduce the risk of electric shock or fire, do not expose this equipment to rain or h Tomoisture. h Always connect ground first and remove last This equipment shall be installed in a manner which prevents unintentional operation by employees, cleaning crew, or others working in the premises. To prevent faulty operation, ensure that all wiring is routed and secured to prevent accidental open or short-circuit conditions. This equipment is not intended for use within the patient care areas of a health care facility. DC 27V tested tested tested Max. V tested tested tested 3 Set of PVMZ / iPVMZ DC 24V tested tested DC 27V tested tested tested Max. V tested tested tested Not Recommended Contact ViewZ •Address : 177 W. Orangethorpe Ave., Placentia, CA 92870 •Phone : (714) 996-1177, Fax : (714) 996-1138 •Sales : sales@viewzusa.com •Specification subject to change without notice.