Installation Guide GE Lighting Solutions GE LED Luminaire (IP180 Series) Features • 0-10V & DALI control (optional) • Long life (50,000 hour rated life) • 5 year warranty • Dry location rated BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT RISK OF ELECTRIC SHOCK • Turn power off before inspection, installation or removal. • Properly ground electrical enclosure. RISK OF FIRE • Follow all NEC and local codes. • Use only UL approved wire for input/output connections. Minimum size 18 AWG. RISQUES DE DÉCHARGES ÉLECTRIQUES • Coupez l’alimentation avant d’’inspecter, installer ou déplacer le luminaire. • Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique. RISQUES D’INCENDIE • Respectez tous les codes NEC et codes locaux. • N’utilisez que des fils approuvés par UL pour les entrées/sorties de connexion. Taille minimum 18 AWG. Save These Instructions Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Tools and components required: •#2 Phillips head screwdriver. •UL Recognized conduit connections per NEC/CEC for nominal conduit trade sizes ½” or ¾”. •UL Recognized wire connectors. Prepare Electrical Wiring Electrical Requirements • The LED driver must be supplied with 100-277 VAC, 50/60 Hz and connected to an individual properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker. Use min. 75°C supply conductor. Grounding Instructions • The grounding and bonding of the overall system shall be done in accordance with National Electric Code (NEC) Article 600 and local codes. imagination at work Unit Installation The luminaires come as a separate master luminaire and a satellite luminaire which must always be installed as a pair. When installing multiple pairs always ensure that adjacent luminaire are of alternating types. The master luminaire differs from the satellite luminaire in that it has an LED driver. No more than one satellite luminaire can be used with each master luminaire. Satellite luminaire Master luminaire 1 Carefully unpack unit from its packaging. Properly inspect for defects before installing. Wear work gloves to prevent dirt and oil from being transferred to the luminaire. 2 Suspend the satellite luminaire adjacent to the master luminaire according to the installation instructions of the selected suspension method before attempting to perform any electrical interconnections. Align tabs with slots 3 Run electrical quick connectors through the through-hole of the two luminaires. Click the male 6-pin connector of the master luminaire to the female connector of the satellite luminaire. Ensure the locking feature on the connectors is firmly engaged. NOTE: A maximum of seven master luminaires and seven satellite luminaires (112 ft.) can be connected on a single through wiring run. IMPORTANT: If the fixtures do not have mating connectors then one has been installed the wrong way around. Reinstall the incorrect fixture before proceeding. 4 Temporarily align two adjacent luminaires by sliding the tabs into the corresponding slots. Optional Continuous Run Mounting: When connecting luminaires in a continuous run, each master/satellite combination is followed by an additional pair(s). Ensure electrical connections are secure and alignment tabs and joiner brackets are securely fastened between each fixture in the run. Install end caps (End Cap Kit 69074) to first and last fixtures in runs. Refer to install instructions in end cap kit (69074) for proper installation. 5 Use bracket from Joiner Kit (69073) to attach luminaires by inserting the curved lower tabs into the slots at the base of the luminaire and rotate the bracket so the upper tabs slide into the slots at the top of the luminaire. Install the two screws (provided in Joiner Kit) with a Phillips head screwdriver. 6 Conceal wires and connection between the luminaires by sliding two joiner covers (provided in Joiner Kit 69073) over the LED light engine so that they engage with a click. Electrical Connections 1 Remove knockout plate from luminaire by loosening the knockout screw and sliding the cover out of luminaire. 2 Carefully remove appropriate knockout for AC line input wires (inner knockout for ½” conduit, outer knockout for ¾” conduit). Install listed electrical fittings in the knockout holes for wire protection and pass supply conduit through electrical fittings. 3 Connect the green (ground) wire to the green ground wire of the luminaire using the provided push-in wirenut. Connect the black (line) and white (neutral) wires of the AC line to the black and white wires of the power supply unit using the provided push-in wire-nuts. 4 Optional dimmer: Install UL listed electrical fitting and insert dimming control wires through. Connect dimming control wires (grey and violet for 1-10V or violet and violet/white strip for DALI) to the similarly colored fixture wire using the provided push-in wire-nuts. Wiring Diagrams 5 Carefully push the wire bundle back into the body of the luminaire. Replace plate and re-tighten mounting screw. 0-10V Line Black Line Black Neutral White Neutral White Ground Green Ground Green (0-10V) + Violet (0-10V) – Grey DALI Violet/White DALI Violet Fixture Fixture DALI Troubleshooting Symptom Solution Luminaires will not turn on • Check that the color of the supply side wires match the color of the wires they are connected to. • Check that the LED driver connector is fully engaged to the LED light engine connector. • Check that the LED light engines are connected at the juction between the two luminaires. Luminaire on through wiring will not turn on • Check that the through wiring connector from the previous fixture in the linear row is fully engaged to the malfunctioning luminaire. Joiner bracket will not fit between two luminaires in a continuous row • Check that the mating tabs between the luminaires are fully engaged. • Check that the two luminaires are on the same level with one another and there is no angle between them. Joiner covers will not click together • Check that the joiner covers are a slot and tab pair not two slotted or two tabbed pieces. • Check that the internal wiring is not in the way of the joiner covers. Suspension method won’t engage with luminaire • Check that the suspension method is one of the approved types in the installation instruction. Specifications Input Voltage 120 – 277V Input Power (complete system)/8 ft. 80W Input Frequency 50/60Hz Power Factor >0.9 THD <20% Control 0-10V/DALI Warranty 5 year limited warranty Dimensions 1 ft. x 8 ft. x 5 in. Environmental Operating Temperature Range -10°C to +25°C Environmental Humidity (non-condensing) 20 to 80% Non-condensing, dry location rated Environmental Storage Temperature Range -40°C to +60°C Weight/8 ft. <35 lbs. Environmental Rating Dry Location Conforms to the following standards: GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com 1-888- 69- 43-533 GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand and logo are trademarks of the General Electric Company. © 2012 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. IND045-121712