Installation Guide — IP18 Series Lumination UL

advertisement
Installation Guide
GE
Lighting Solutions
GE LED Luminaire
(IP180 Series)
Features
• 0-10V & DALI control (optional)
• Long life (50,000 hour rated life)
• 5 year warranty
• Dry location rated
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
• Turn power off before inspection, installation or removal.
• Properly ground electrical enclosure.
RISK OF FIRE
• Follow all NEC and local codes.
• Use only UL approved wire for input/output connections.
Minimum size 18 AWG.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation avant d’’inspecter, installer ou déplacer le luminaire.
• Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique.
RISQUES D’INCENDIE
• Respectez tous les codes NEC et codes locaux.
• N’utilisez que des fils approuvés par UL pour les entrées/sorties de connexion. Taille minimum 18 AWG.
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Tools and components required:
•#2 Phillips head screwdriver.
•UL Recognized conduit connections per NEC/CEC for nominal conduit trade sizes ½” or ¾”.
•UL Recognized wire connectors.
Prepare Electrical Wiring
Electrical Requirements
• The LED driver must be supplied with 100-277 VAC, 50/60 Hz and connected to an individual properly
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker. Use min. 75°C supply conductor.
Grounding Instructions
• The grounding and bonding of the overall system shall be done in accordance with National Electric Code
(NEC) Article 600 and local codes.
imagination at work
Unit Installation
The luminaires come as a separate master luminaire and a satellite luminaire which must always be installed as a pair. When installing
multiple pairs always ensure that adjacent luminaire are of alternating types. The master luminaire differs from the satellite luminaire in
that it has an LED driver. No more than one satellite luminaire can be used with each master luminaire.
Satellite luminaire
Master luminaire
1
Carefully unpack unit from its packaging. Properly inspect
for defects before installing. Wear work gloves to prevent
dirt and oil from being transferred to the luminaire.
2
Suspend the satellite luminaire adjacent to the master
luminaire according to the installation instructions of
the selected suspension method before attempting to
perform any electrical interconnections.
Align tabs with slots
3
Run electrical quick connectors through the through-hole
of the two luminaires. Click the male 6-pin connector
of the master luminaire to the female connector of the
satellite luminaire. Ensure the locking feature on the
connectors is firmly engaged.
NOTE: A maximum of seven master luminaires and seven
satellite luminaires (112 ft.) can be connected on a single
through wiring run.
IMPORTANT: If the fixtures do not have mating
connectors then one has been installed the wrong way
around. Reinstall the incorrect fixture before proceeding.
4
Temporarily align two adjacent luminaires by sliding the
tabs into the corresponding slots.
Optional Continuous Run Mounting:
When connecting luminaires in a continuous run, each
master/satellite combination is followed by an additional
pair(s). Ensure electrical connections are secure and
alignment tabs and joiner brackets are securely
fastened between each fixture in the run. Install end
caps (End Cap Kit 69074) to first and last fixtures in runs.
Refer to install instructions in end cap kit (69074) for
proper installation.
5
Use bracket from Joiner Kit (69073) to attach luminaires
by inserting the curved lower tabs into the slots at the
base of the luminaire and rotate the bracket so the
upper tabs slide into the slots at the top of the luminaire.
Install the two screws (provided in Joiner Kit) with a
Phillips head screwdriver.
6
Conceal wires and connection between the luminaires by
sliding two joiner covers (provided in Joiner Kit 69073) over
the LED light engine so that they engage with a click.
Electrical Connections
1
Remove knockout plate from luminaire by loosening the
knockout screw and sliding the cover out of luminaire.
2
Carefully remove appropriate knockout for AC line input
wires (inner knockout for ½” conduit, outer knockout
for ¾” conduit). Install listed electrical fittings in the
knockout holes for wire protection and pass supply
conduit through electrical fittings.
3
Connect the green (ground) wire to the green ground
wire of the luminaire using the provided push-in wirenut. Connect the black (line) and white (neutral) wires
of the AC line to the black and white wires of the power
supply unit using the provided push-in wire-nuts.
4
Optional dimmer: Install UL listed electrical fitting and
insert dimming control wires through. Connect dimming
control wires (grey and violet for 1-10V or violet and
violet/white strip for DALI) to the similarly colored fixture
wire using the provided push-in wire-nuts.
Wiring Diagrams
5
Carefully push the wire bundle back into the body of the
luminaire. Replace plate and re-tighten mounting screw.
0-10V
Line
Black
Line
Black
Neutral
White
Neutral
White
Ground
Green
Ground
Green
(0-10V) +
Violet
(0-10V) –
Grey
DALI
Violet/White
DALI
Violet
Fixture
Fixture
DALI
Troubleshooting
Symptom
Solution
Luminaires will not turn on
• Check that the color of the supply side wires match the color of the wires they are connected to.
• Check that the LED driver connector is fully engaged to the LED light engine connector.
• Check that the LED light engines are connected at the juction between the two luminaires.
Luminaire on through wiring will
not turn on
• Check that the through wiring connector from the previous fixture in the linear row is fully
engaged to the malfunctioning luminaire.
Joiner bracket will not fit
between two luminaires in a
continuous row
• Check that the mating tabs between the luminaires are fully engaged.
• Check that the two luminaires are on the same level with one another and there is no angle
between them.
Joiner covers will not click
together
• Check that the joiner covers are a slot and tab pair not two slotted or two tabbed pieces.
• Check that the internal wiring is not in the way of the joiner covers.
Suspension method won’t
engage with luminaire
• Check that the suspension method is one of the approved types in the installation instruction.
Specifications
Input Voltage
120 – 277V
Input Power (complete system)/8 ft.
80W
Input Frequency
50/60Hz
Power Factor
>0.9
THD
<20%
Control
0-10V/DALI
Warranty
5 year limited warranty
Dimensions
1 ft. x 8 ft. x 5 in.
Environmental Operating Temperature Range
-10°C to +25°C
Environmental Humidity (non-condensing)
20 to 80% Non-condensing, dry location rated
Environmental Storage Temperature Range
-40°C to +60°C
Weight/8 ft.
<35 lbs.
Environmental Rating
Dry Location
Conforms to the following standards:
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1-888- 69- 43-533
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand and logo are trademarks of the General Electric Company.
© 2012 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
IND045-121712
Download