DIN rail mount type TB559, 556, 564, 563 series • 24-hour program (TB559, TB556) • Weekly program (TB564, TB563) • 300-hour reserve battery (TB556, TB563) • With robust metal setting pins • DIN 3P module Applicable installation Dimensions (unit: mm) Indoor use 66.5 61 44 54 Series TB559 series TB556 series TB564 series Item No. TB5590185N TB5560187N TB5640185N TB5630187N Operating voltage / frequency 230V AC 50Hz 220-240V AC 50-60Hz 230V AC 50Hz 220-240V AC 50-60Hz Drive method AC motor Quartz motor AC motor Power reserve Time accuracy Load capacity 110 45 90 DIN railmounting grove Terminal cover (option parts) TB563 series Quartz motor 300 hours(at 25˚C) 300 hours(at 25˚C) Same as AC frequency ±15 sec/month(at 25˚C) Same as AC frequency ±15 sec/month(at 25˚C) Circuit configuration No voltage contact output Type of contact Single pole, double through (1c Contact) 250V AC 16A Resistive load(cosø=1) Inductive load(cosø=0.6) >time Shortest switching= Number of ON/OFF> =operations 33 34.5 Weekly Daily Program 250V AC 3A 15 minutes 2 hours (*1) 96 operations 84 operations *1. Operating time accuracy is ±30 minutes. DIN rail mount type TB62 series (Digital) • Weekly type • 6-year reserve battery • With a manual ON/OFF button • Possible to lock the manual button • Holiday setting function • Manual ±1 hour changeover function • DIN 2P module Dimensions (unit: mm) Applicable installation 61 55 44 40 35 33 5.5 Weekly Series TB62 series Item No. 1.8 TB621018A7(1circuit) TB622018A7(2circuits) Operating voltage / frequency 220-240V AC 50-60Hz Drive method Electronic Front cover Power reserve 6 years Time accuracy ±15 sec/month(at 25°C) Circuit configuration No voltage contact output Type of contact Single pole, double through (1c Contact) 65.2 45 Mounting plate (option parts) Load capacity 65 45 130 90 Indoor use Program Terminal cover (option parts) 34.5 Resistive load(cosø=1) 250V AC 16A Inductive load(cosø=0.6) >time Shortest switching= 250V AC 8A Number of ON/OFF> =operations 78 1 minute 50 operations (ON/OFF 25 sets) / circuit Surface & DIN rail mount type TB35N, 36N, 38N, 39N series • 24-hour program • Surface and DIN rail mount • 300-hour reserve battery (TB38N, 39N) • Battery exchange from the front side. • 96 operations per day • Shortest switching time is 15 minutes. • Easy to read and set, clock display. Applicable installation Indoor use Program Dimensions (unit: mm) Daily Series TB35N series TB36N series TB38N series TB39N series TB38809NE7 Item No. TB35809NE5 TB35809NE6 TB36809NE5 Operating voltage / frequency 220-240V AC 50Hz 220-240V AC 60Hz 220-240V AC 50Hz Drive method AC Motor Quartz Motor Same as AC frequency ±15 sec/month(at 25˚C) Power reserve 300 hours Time accuracy Load capacity TB39809NE7 220-240V AC 50-60Hz Circuit configuration Voltage contact output No voltage contact output Voltage contact output No voltage contact output Type of contact Single pole, single through (1a Contact) Single pole, double through (1c Contact) Single pole, single through Single pole, double through (1a Contact) (1c Contact) Resistive load(cosø=1) 250V AC 20A Incandescent lamp load Inductive load(cosø Motor load(cosø 250V AC 10A 0.6) 250V AC 12A 0.6) 220V AC 1500W Shortest switching time 15 minutes Number of ON/OFF operations 96 operations Applicable installation Indoor use Surface mount type TB17N, TB11N series • 24-hour program • ON/OFF operations are set with separated pins • With a manual ON/OFF switch • 300 hours reserve battery (TB11N) • Battery exchange from the front side. Program Dimensions (unit: mm) �8 16.5 Item No. TB178NE5 Operating voltage / frequency �4.5 50 TB118NE7 220-240V AC 50Hz 220-240V AC 60Hz AC Motor 220-240V AC 50-60Hz Quartz Motor Same as AC frequency ±15 sec/month(at 25˚C) 300 hours Time accuracy Load capacity 31.5 TB11N series TB178NE6 Power reserve 120 101 (Fixing Pitch) 123 2.5 TB17N series Drive method Front Cover 72 Daily Series Circuit configuration Voltage contact output Type of contact Single pole, single through (1a Contact) Resistive load(cosø=1) 250V AC 15A Incandescent lamp load 250V AC 15A Inductive load(cosø Motor load(cosø 0.6) 0.6) 250V AC 12A 220V AC 1500W Shortest switching time 30 minutes Number of ON/OFF operations Standard 6 operations (Max. 48 operations) 79 Surface mount type TB35N, 38N series (Steel box type) • Robust steel box • 24-hour program • Surface mount • 300-hour reserve battery (TB38N) • Battery exchange from the front side. • 96 operations per day • Shortest switching time is 15 minutes. • Easy to read and set, clock display. Applicable installation Indoor use Program Dimensions (unit: mm) Daily Series TB35N series Item No. TB358NE5 Operating voltage / frequency Drive method TB38N series TB358NE6 TB388NE7 220-240V AC 50Hz 220-240V AC 60Hz AC Motor 220-240V AC 50-60Hz Quartz Motor Same as AC frequency ±15 sec/month(at 25˚C) Power reserve 300 hours Load capacity Time accuracy Circuit configuration Voltage contact output Type of contact Single pole, single through (1a Contact) Resistive load(cosø=1) 250V AC 20A Incandescent lamp load 250V AC 10A Inductive load(cosø Motor load(cosø 0.6) 0.6) 250V AC 12A 220V AC 1500W Shortest switching time 15 minutes Number of ON/OFF operations 96 operations Applicable installation Outdoor and Indoor use Surface mount type TB43N series (Weatherproof) • Weatherproof type (IP53) • 24-hour program • Surface mount • 300-hour reserve battery • Battery exchange from the front side. • 96 operations per day • Shortest switching time is 15 minutes. • Easy to read and set, clock display. Program Daily Series TB43N series Item No. TB438NE7 Operating voltage / frequency 220-240V AC 50-60Hz Quartz Motor Dimensions (unit: mm) Load capacity Drive method 80 Power reserve 300 hours Time accuracy ±15 sec/month(at 25˚C) Circuit configuration No voltage contact output Type of contact Single pole, single through (1a Contact) Resistive load(cosø=1) 250V AC 20A Incandescent lamp load 250V AC 10A Inductive load(cosø Motor load(cosø 0.6) 0.6) 250V AC 12A 220V AC 1500W Shortest switching time 15 minutes Number of ON/OFF operations 96 operations 80 Wiring Examples Single Pole, Single Through (1a Contact) When a magnetic switch and contactor are used together When direct controlled by a time switch Single phase Three phase Time Switch Time Switch S2 S1 S2 S1 L2 S2 S1 Time Switch When the time switch and load power supply are separate L2 L2 L1 L1 Power source L1 Power source Power source Load Power source 3 4 1 2 MC A1 Power source No voltage contact output Load 96 13 Power source 1 2 3 4 5 6 MgS 95 Load A2 A1 Electromagnetic switch A2 Electromagnetic switch Note: Before operating, take off all protective wires of electromagnetic switch shown with dotted lines in diagram. Time Switch When the time switch and load power supply are the same (Connect a crossover wire between S2 and L2 .) Time Switch S2 S1 S2 S1 Time Switch S2 S1 L2 L2 L1 96 13 L1 Power source L2 L1 Load Power source Power source 3 4 1 2 MC A1 Load 1 2 3 4 5 6 95 Load MgS A2 A1 Electromagnetic switch A2 Electromagnetic switch Note: Before operating, take off all protective wires of electromagnetic switch shown with dotted lines in diagram. Time Switch Time Switch S1 Time Switch Voltage contact output When the time switch and load power supply are the same S1 S2 S1 L2 S2 L2 L1 L2 S2 L1 96 13 L1 Power source Load Power source 3 4 1 A1 MC Load 1 Power source 3 2 Load 4 5 A2 95 2 MgS 6 A2 A1 Electromagnetic switch Electromagnetic switch Note: Before operating, take off all protective wires of electromagnetic switch shown with dotted lines in diagram. Single Pole, Double Through (1c Contact) When a magnetic switch and contactor are used together When direct controlled by a time switch Single phase Three phase Time Switch Time Switch Time Switch When the time switch and load power supply are separate S1 S2 S1 COM NO S2 COM S1 NO S2 NC Load Power source 3 4 1 A1 No voltage contact output NO Power source Power source Power source COM Power source NC NC MC Load 13 Power source 2 2 3 4 5 6 A1 A2 96 1 MgS 95 Load A2 Electromagnetic switch Electromagnetic switch Note: Before operating, take off all protective wires of electromagnetic switch shown with dotted lines in diagram. Time Switch Time Switch When the time switch and load power supply are the same (Connect a crossover wire between S2 and COM .) Time Switch S1 Power source S2 COM NO S1 S2 COM S1 NO S2 COM NO NC NC NC 13 Load Power source Power source 3 1 A1 4 MC 2 A2 Electromagnetic switch Load 96 1 2 3 4 5 A1 MgS 95 Load 6 A2 Electromagnetic switch Note: Before operating, take off all protective wires of electromagnetic switch shown with dotted lines in diagram. 81