Power Supply Unit Series for LED Lights Type Feature Power Supply Units for Regular Lighting Digital power supply Repeatable, linear light intensity control Intensity control with 256 discrete levels using course and fine adjustments 1-channel Full featured external control functionality Multi-channel, independent intensity control Analog power supply Intensity control with 256 discrete levels using course and fine adjustments 2-channel, 4-channel, or 8-channel models Full featured external control functionality Continuous intensity control for simple, cost sensitive applications with Analog step-less intensity control Strobe unit HSL HLND / Stops motion with short overdriven pulse Strobe with pulse width from 10 µms to 99 0 µms, 10% duty cycle max 2-channel type PD2-1012 12V / 9.5W 100 ~ 120V AC 27VA 1 PD2-1024 24V / 9.0W 100 ~ 120V AC 27VA 1 PD2-3012 12V / 28W 100 ~ 240V AC 78VA 1 PD2-3024 24V / 28W 100 ~ 240V AC 78VA 1 PD2-5012 12V / 46W 100 ~ 240V AC 122VA 1 PD2-5024 24V / 46W 100 ~ 240V AC 122VA 1 PD2-3012-2 12V / 28W 100 ~ 240V AC 78VA 2 PD2-3024-2 24V / 28W 100 ~ 240V AC 78VA 2 PD2-3012-4 12V / 27W 100 ~ 240V AC 78VA 4 PD2-3024-4 24V / 27W 100 ~ 240V AC 78VA 4 PD2-3012-8 12V / 25W 100 ~ 240V AC 78VA 8 PD2-3024-8 24V / 25W 100 ~ 240V AC 78VA 8 PSB-512V 12V / 5W 100 ~ 120V AC 15VA 1 PSB-524V 24V / 5W 100 ~ 120V AC 15VA 1 PSB-1012VB 12V / 10W 100 ~ 120V AC 27VA 1 PSB-1024VB 24V / 10W 100 ~ 120V AC 27VA 1 PSB-3012VB 12V / 30W 100 ~ 120V AC 78VA 1 PSB-3024VB 24V / 30W 100 ~ 120V AC 78VA 1 PSB-1012V-WW (3) Select from 2-channel, 4-channel, or 8-channel models to according to the number of independent outputs needed (multiple lights can be connected to a single output channel with a 2 or 4 way split cables. 12V / 10W 100 ~ 240V AC 27VA 1 (4) Select one of the optional external control cables. (Refer to information on page 63) PSB-1024V-WW 24V / 10W 100 ~ 240V AC 27VA 1 12V DC / 24W 22V DC / 24W PD2 Series Specifications 24V DC 12V / 24V x 1 PB-2430 PTU2-3012 PTU2-3024 PSB2-10024-EX DIN rail installation standard 2-channel, or 3-channel type Analog step-less dimming setup External control function incorporated DIN rail models available (2CD/3CD) CAUTION 61 Number of channels HLND Series dedicated power supply unit HSL Series dedicated power supply unit RoHS Directive Compatible Power required PS-3012-D24 Analog step-less dimming setup External control function incorporated Digital Power Supplies Output Model Low cost 12V output, 24V input overdriving strobe controller HLV Series dedicated power supply unit HLV Dedicated power supply Strobe power supply Enabling to introduce a power supply by keeping costs low RoHS Directive Compatible PSB2-30024-EX PHL-0508-CD24 12V / 27W 24V / 27W 100 ~ 240V AC 78VA 100 ~ 240V AC 78VA Page listed 2 P62/ P63 1 12V ~ 24V / 300W 100 ~ 120V AC / 200 ~ 240V AC 900VA 1 24V DC 1 PJ-1505-2CA 100 ~ 240V AC 27VA 2 PJ-1505-3CA 100 ~ 240V AC 37VA 3 PJ-1505-2CD24 24V DC 2 PJ-1505-3CD24 24V DC 3 Ensure total power consumption (W) of lights connected and simultaneously powered do not exceed the chosen controllers power rating. Failure to do so will reduce maximum achievable light intensity. PD2-3012 / PD2-3024 / PD2-5012 / PD2-5024 / PD2-3012-2 / PD2-3024-2 / PD2-3012-4 / PD2-3024-4 / PD2-3012-8 / PD2-3024-8 The PD2 Series of digital power supplies are designed specifically for use with CCS LED lights. Compared with analog power supplies, the PD2 Series provides a more linear and repeatable intensity control because of the force-detent adjustment course/fine adjustment knobs and benefits of pulse duty control. The PD2 Series is suitable for all CCS lights without dedicated power supplies. The Series is designed to meet the requirements of the widest variety of applications with the 12 and 24V options, power ratings range, and the number of independent output channels. The PD2 Series is compatible with RoHS Directive*, ensuring compatibility with worldwide requirements. PD2-1012/PD2-1024 PD2-3012/PD2-3024 PD2-5012/PD2-5024 PD2-3012-2/PD2-3024-2 PD2-3012-4/PD2-3024-4 PD2-3012-8/PD2-3024-8 Selecting a PD2 Series power supply P64 (1) Select a12-V or 24-V output models according to the voltage of a LED lights used. (2) Select from the 10-watt or 30-watt models according to the total of power consumption of LED lights to be used. P64 Model Input voltage 1) P65 P66 100 ~ 120V AC / 200 ~ 240V AC 240VA PD2 Series Offers repeatable, linear light intensity control with 256 discrete levels using course and fine adjustments 2 12V ~ 24V / 100W Models with CE Marking: P39 Input current 2) PD2-1024 PD2-3024 PD2-5012 PD2-5024 PD2-3012-2 PD2-3024-2 PD2-3012-4 PD2-3024-4 PD2-3012-8 PD2-3024-8 100~240V AC 0.78A typ. 1.3A typ. 0.78A typ. 50/60Hz 15A typ. Inrush current 2) Number of channels 1 1 1 1 1 1 2 2 4 4 8 8 DC output voltage 12V 24V 12V 24V 12V 24V 12V 24V 12V 24V 12V 24V 28W max. 46W max. 46W max. 28W max. 28W max. 27W max. 27W max. 25W max. 25W max. Output power External control input 9.5W max. 9.0W max. 28W max. Control method : 60kHz (approx.) pulse duty control Manual : 256-level of intensity control using dual 16 position Coarse and Fine rotary knob on the control panel External control : Intensity control using 8-bit parallel signal Input circuit ON/OFF control : At + 5.0V with 4.7k D-Sub 15-pin (male) D-Sub 25-pin (male) Manual : 3.5-mm microphone jack External control : D-Sub 15-pin ON signal (Asynchronous with write sequence) ON/OFF response : D-Sub 25-pin OFF signal Manual/ External control (Asynchronous with write sequence) OFF - ON: 10µs typ., ON - OFF: 10µs typ. Startup time Output overcurrent protection Input circuit : At + 5.0V with 1.5k Pull-up resistor. Pull-up resistor. HS-CMOS, Low level: 1.35V or less, High level: 3.15V or more External control connector P56 PD2-3012 100~120V AC 0.25A typ. Frequency Intensity control P50 PD2-1012 0.5sec typ. Activated by 107% minimum of the rated output current and reset by turning the power supply ON with front panel power switch. Operating environment Temperature 0 to 40 C, humidity 20 to 85%RH (with no condensation) Storage environment Temperature -20 to 60 C, humidity 20 to 85%RH (with no condensation) Weight 0.7kg or less 1.1kg or less 1.3kg or less 1.1kg or less 1.2kg or less 1.5kg or less 1) Operating voltage: 85 to 132VAC or 85 to 264VAC, 2) At a voltage of 100VAC 62 Analog Power Supplies PD2 Series Dimensions (Unit: mm) PD2-3012 / 3024 (8) (7) 230 PSB Series 9 AC cable (2.3 m) External Control 93 13.5 12 62 12 11.5 4-M3 depth 3 54x93(screw hole for securing) PD2-3012-2 / 3024-2 (7) 8 9 10 11 12 13 14 15 2 1 16 L1 40 10.5 L1 (FAN) Error Power 20 130 20 140 15 11.5 PD2-3012-4 / 3024-4 170 100-240V 50/60HZ 122VA External Control 15 L1 4-M3 depth 5 (screw hole for securing) 4-M3 depth 5 40x200(screw hole for securing) L2 40 10.5 20 190 20 15 200 15 Coarse 7 6 5 4 3 8 9 10 11 12 13 14 15 2 1 16 7 6 5 4 3 8 9 10 11 12 13 14 15 2 1 16 Fine Power 110 100-240V~ 50/60Hz 78VA 10 13.5 5.5 16 4-M3 depth 5 40x140 (screw hole for securing) 90 100-120V~ 50/60Hz 27VA CCS Standard Analog Power Supplies 62 15 PD2-5024 9.3 7 6 5 4 3 Light on/off 200 Error PD2-3012-8 / 3024-8 9 9 PD2-3012-4 7 6 5 4 3 8 9 10 11 12 13 14 15 2 1 16 L1 7 6 5 4 3 8 9 10 Coarse 8 9 10 11 7 11 12 6 12 13 5 13 14 4 14 15 3 15 2 1 16 2 1 16 L2 Fine 7 6 5 4 3 PSB-1012V-WW / PSB-1024V-WW 5.5 Coarse 8 9 10 11 12 13 14 15 2 1 16 15 10.7 PD2-3012 L1 7 6 5 4 3 110 L1 (FAN) On/Off External Control Light FG 54 External control connector D-Sub 15-pin Fine Fine PD2-1012 16 62 4-M3 depth 5 (screw hole for securing) L2 8 9 10 11 12 13 14 15 2 1 16 15 5.5 7 6 5 4 3 Light 140 L1 90 8 9 10 11 12 13 14 15 2 1 16 Coarse 54 7 6 5 4 3 Error Power On/Off 15 10 External control connector D-Sub 15-pin 86 External control connector D-Sub 15-pin Models with CE Marking 170 90 100-240V~ 50/60Hz 78VA 10 External Control 4-M3 depth 5 40x140 (screw hole for securing) 11.5 40 10.5 Power 20 130 20 15 140 15 8 9 10 11 6 12 5 13 4 14 3 15 2 1 16 L1 4-M3 depth 5 85x140 (screw hole for securing) Error 20 15 L2 L3 External Control L4 8 9 10 11 12 13 14 15 2 1 16 7 6 5 4 3 L1 7 6 5 4 3 100-240V~ 50/60Hz 78VA 8 9 10 11 12 13 14 15 2 1 16 L5 8 9 10 Coarse 8 9 10 11 7 11 12 6 12 13 5 13 14 4 14 15 3 15 2 1 16 2 1 16 L2 7 6 5 4 3 Fine 8 9 10 Coarse 8 9 10 11 7 11 12 6 12 13 5 13 14 4 14 15 3 15 2 1 16 2 1 16 L6 Fine 7 6 5 4 3 L3 L7 8 9 10 11 12 13 14 15 2 1 16 Error 7 6 5 4 3 8 9 10 11 12 13 14 15 2 1 16 L8 20 15 12.5 85 12.5 12.5 L2 L3 L4 L5 L6 L7 4-M3 85x140 (screw hole for securing) L8 100-240V~ 50/60Hz 78VA High Low 85 12.5 15 140 15 20 130 20 Options for PD2 Series External control cable for Intensity AND On/Off For 1-channel or 2-channel type (D-Sub 15-pin)・・・・・EXCB2-B3 (3m) For 4-channel or 8-channel type (D-Sub 25-pin)・・・・・EXCB2-25-3 (3m) External control cable for ON/OFF ONLY For 1-channel or 2-channel type (3.5-mm microphone jack)・・・・・NFCB2-3 (3m) Digital Power Supply PDS-30 Models with CE Marking PDS-30 Compact and Multifunctional High-Performance Specifications Input voltage Input current Frequency Light voltage NO.of channels Output power PWM frequency Light intensity steps Strobe duration Emission delay RS-232C External control Bit parallel input Trigger input Operating environment Storage environment Weight RoHS Directive Compatible 100 to 240V AC 1.0A max. (100V AC IN) 0.5A max. (200V AC) 50 / 60Hz 10% 12 V , 24 V 1 30W 50 1 kHz Continuous: 256 steps, Strobe: 128 steps 16 steps: 20,40,60,80,100,140,180,260,400,500,1000µs, 3,5,8,10,33ms 10µs 16 steps: None (10µs max.) 30,60,80,100,150,200,250,300,500,750µs,1,2,4,8,10ms 10µs Light intensity settings Strobe duration Strobe delay Trigger output delay Inquire Reset Version confirmation Baud rate, 9600 bps Data, 8 bits Stop bit, 1 bit Non-parity Light intensity, 8-bit INT/EXT WR ON/OFF Non-insulated, 5-V CMOS level input Pulse width 20 µs min., rise/fall 10 µs max. Non-insulated, 5-V CMOS level input 0 to 40°C, 20 to 85% humidity (with no condensation) -20 to 60°C, 20 to 85% humidity (with no condensation) 1200g max. The PSB Series is an analog power supply series providing stepless intensity control through variable voltage control. It is ideal for continuous use with cameras having a shutter speed of 1/4000 or faster. Worldwise type also available. SMP-03VX1 PSB-3012VB AC100 ~ 120V 78VA 12V/30W 1 SMP-02VX2 PSB-3024VB AC100 ~ 120V 78VA 24V/30W 1 SMP-03VX2 PSB-1012V-WW AC100 ~ 240V 27VA 12V/10W 1 SMP-02VX1 PSB-1024V-WW AC100 ~ 240V 27VA 24V/10W 1 SMP-03VX1 113 PSB-1012VB / 1024VB (17) 117 10.5 12V 24V AC cable (2.3m) 65 Compact and Efficient PB-2430 Models with CE Marking PB-2430 The single power supply handles the 12V and 24V type of CCS LED lights at the same time, and allows the user to control the light intensity of each one simultaneously or separately. It operates with 24VDC voltage input. Part Names and Functions Output connector for 12V LED lights Strobe Cont. Remote Manual RS-232C Parallel Trig.+ Trig.ON/OFF+ ON/OFFDelay Intensity ON OFF GND L2-2 ON/OFF RS-232C L1/L2(FAN) 100-240V 50/60Hz 110VA FG ON OFF TEST 40 62 22 12.5 40 PSB-3012VB / 3024VB 148 14 12.5 93 10 11 54 11 PSB-1012V-WW / 1024V-WW (17) (8.5) 131 (15) AC cable (2.3m) 76 86 GND LIGHT 100-240V 14 120 14 GND 8 70 8 Specifications 15.5 100 15.5 11 5 6 4 7 3 8 9 2 10 1 INTENSITY POWER 54 11 RoHS Directive Compatible Input 24VDC 10%, 50W max (36W typ.) DC output L1: 12VDC 2A 24W max., L2: 22VDC 1.1A 24W max. Total power consumption must not exceed 30W max. Output voltage range/ Light intensity control L1: Approx, 8.3 to 12.0VDC L2: Approx. 15.0 to 22.0VDC Intensity control by the 'ADJUST' potentiometers Input terminal Two terminals with 7.62 mm pitch, M3 screw Output Connector L1: SMP-02V-BC [JST] 1: Output + 2: Output L2: SMP-03V-BC [JST] 1. Output + 2: NC 3:Output - Over-current protection Built-in input Polyswitch Insulation Non-insulation between input and output Cooling method Natural air-cooling Weight Approx. 300g Note: 1) When input voltage decreases, the output L2 will also decrease (Input voltage must be 1.5V or higher than output voltage). 24VDC input terminals Light w/fan output connector RS232C control connector BIT PARALLEL 11 9.5 POWER 80 L2-1 TRIGGER 5 ON 76 GND 24V light output connector L1-2 L1-1 NC 90 (ms) 3 5 8 1000 10 500 33 20 PULSE WIDTH 400 260 40 180 60 ( s) 140 100 80 B C D A E 9 F 8 0 COARSE 1 7 6 2 5 4 3 LIGHT CONTROL B C D A E 9 F 8 0 FINE 1 7 6 2 5 4 3 MODE 110 By switching the voltage, 12-V and 24-V LEDs can be used. (17) 12V light output connector 4-M3 depth 2 ( for side installation) VOLTAGE 63 1 Dimensions (Unit: mm) PDS-30 In addition to parallel control, a function allowing remote control of the light intensity via RS-232C is provided. 24V/10W * Models with lock of dimming control knob are available as option. Models: PSB-512VL/PSB-524VL/PSB-1012VBL/PSB-1024VBL/ PSB-3012VBL/PSB-3024VBL PDS-30 Choose from three types: ON, Strobe ON, and Remote Mode. AC100 ~ 120V 27VA 11 Dimensions (Unit: mm) Each 16 steps are provided for Coarse and Fine adjustment, providing 256 steps light control. SMP-02VX1 PSB-1024VB PSB-1012VB/PSB-1024VB External Control Ext Mode On Off 140 L1 L4 Power 130 SMP-03VX1 1 PD2-3012-8 7 6 5 4 3 8 9 10 11 12 13 14 15 2 1 16 7 1 12V/10W 5 42 7 6 5 4 3 Fine 8 9 10 11 6 12 5 13 4 14 3 15 2 1 16 24V/5W AC100 ~ 120V 27VA GND External control connector D-Sub 25-pin 110 122 L2 Coarse 8 9 10 11 12 13 14 15 2 1 16 7 External control connector D-Sub 25-pin 110 5.5 L1 7 6 5 4 3 (8) 80 L2 170 AC100 ~ 120V 15VA PSB-1012VB High Low 5.5 4-M3 depth 5 (screw hole for securing) L1 L1 (FAN) 9 PD2-3012-2 110 2 62 15 5.5 Light 1 10 On/Off 140 PSB-524V Ext Mode On Off 15 SMP-02VX1 AC cable (2.3m) Power External control connector D-Sub 15-pin 1 PSB-3012VB/PSB-3024VB L4 Error Connector 12V/5W PSB-512V / 524V 8 9 10 11 12 13 14 15 2 1 16 L3 Circuit AC100 ~ 120V 15VA Dimensions (Unit: mm) PSB-512V/PSB-524V (8) Output PSB-512V 5 45 120 9 170 Power requirements 5 50 9 PD2-5012 / 5024 (7) RoHS Directive Compatible Model 5 55 PD2-1012 / 1024 Specifications 15 140 170 Parallel control connector Output connector for 24V LED lights 15 Intensity control for 12V LED lights Intensity control for 24V LED lights 4-M3 depth 2 64 Strobe Power Supplies PTU2-3012/PTU2-3024 Compatible with more than CCS LED lights The PTU power supply Series enables CCS standard lights to be used with strobes. It enables the lights to emit several times bright than using the On/Off control function of the conventional PSB and PD Series, or by strobe lighting using STU-3000. The units have two independent circuits with separate controls for each circuit. The strobe illumination time can be set from 10 µs to 990 µs using rotary controls. Part Names and Functions Trigger Setting Selectable trigger mode. Ext : External Trigger I n t : Internal Trigger Trigger Controller Connector (D-sub 25) Used to connect an external controller. Specifications RoHS Directive Compatible Output 2 circuits max, 27W Illumination Mode (Strobe) Internal Trigger/External Trigger Trigger Input Photocoupler Input (5 mA), with Insulated Power Supply Power Supply 100 ~ 240V AC 78VA Output Connector SMP-02V X 2 (12V) / SMP-03V X 2 (24V) Trigger Input Connector D-sub 25pin, male Strobe illumination Vidth 10µs to 990µs, set with 2-digit thumb-rotary switch Trigger Cycle Int: 1msec, Ext: 1msec or more at 10% duty or less Option External Trigger Cable: STCB-25-3 (3m) Strobe Power Supply Dimensions (Unit: mm) PTU-3012 / 3024 STU-3000 Output Strobe output, 18VDC, 8A max. (The peak value of using 30W of load.) DrivableIlluminators 12V/30W max. Input terminal 7 terminals with 7.62mm pitch, M3 screw Output Connector SMP-02V-BC [JST] (Pin 1: + Pin 2: -) Lighting Method Strobe with overdriving (Built-in Protection Circuit) Pulse Width 10.0µs-1.0ms (Pulse width control by potentiometer) Trigger Interval 12.5ms min, (The trigger interval to the next signal should be more than 12.5ms, otherwise the signal will be ignored.) Trigger Input Photo-coupler input, Input current 5mA or more, Over 20µs pulse width, Rise/Fall time 10µs max. Delay Time Max. 10µs (Trigger input-Strobing) Cost-effective, easy-to-use strobe power supply with overdriving power output 110 Overdriving capability provides all CCS 12V standard lights 2-3 times brighter Pulse Width 100-240V AC GND Out put Connectors Connect 12/24V lights. 80 12.5 4-M3 depth 5 85X145 (used for fixing screw hole) 125 145 12.5 Specifications 1 1 Int 50 POWER L2 L1 Ext L2 60 1 1 Control (%) 70 50 80 40 40 60 90 L1 70 80 30 90 30 90 20 10 100 20 10 100 12.5 85 5.5 EXT 12.5 High performance allows synchronization of light and camera Rugged, compact housing For use with 24VDC input RoHS Directive Compatible SMP-04V-BC (12V DC or 24V DC) M3 terminal block 3P (Trig+ Trig- FG) SMP-02V-BC (12V DC) SMP-03V-BC (24V DC) M3 jack (ON/OFF control signal) Input Achievement of strobe function in combination with CCS's digital power supply 24VDC 10% 20W minimum (average) (18) 170 Light Volume Models with CE Marking STU-3000 Input PS-3012-D24 (8) Strobe Unit RoHS Directive Compatible Dimensions (Unit: mm) Ext : The two channels can be set indenpendently from 10 to 990 µsec. I n t : 100µs Fixed Power Supply Switch PS-3012-D24 Models with CE Marking PS-3012-D24 Specifications Models with CE Marking : PTU2-3012/PTU2-3024 Pulse Width Setting The light intensity can be set as a ratio of the set pulse width, from 10% to 100%. High Performance and Low Price Output Trigger Photo-coupler input 5V to 24V DC Current: 5mA max. Pulse width: 20 s min. Rising / falling edge: 10 s max. ON/OFF control signal Connection to lighting ON/OFF jack of the PD/PD2 power supply Inside: Signal Outside: GND ON pulse width Set with the 4-digit thumbwheel switch (0.01 to 99.99ms). Light delay 10 s max. Accessories ON/OFF control cable Power cable (12V) / Power cable (24V) Weight 0.4kg max. Connectable power supply PD-1012/1024/3012/3024/5024/3012-2/3024-2 PD2-1012/1024/3012/3024/5012/5024/3012-2/ 3024-2/Other optional power supply *For uses requiring large light volumes in short time periods, use the PTU2 Series. Dimensions (Unit: mm) STU-3000 Pulse width switch Trigger input terminal 110 65 70 By connecting the STU-3000 to CCS's PD and PD2 Series digital power supplies, an ambient light can be used as a strobe light. The one-shot circuit in the adaptor is activated by external trigger signals, the power ON/OFF supply is controlled at a defined pulse width, and an LED light is flashed as a strobe light. The strobe flash time can be set between 0.01 and 99.99msec. by means of the four-digit digital switch. Output connector for lighting 12V Control output connector + _ FG msec STU-3000 Output connector for lighting 24V 31 TRIGGER PULSE WIDTH TEST TEST button Input connector 66 Optional Optional Parts Parts A wide variety of optional parts are available. Optional Optional Cable Cable Select a cable to match the light used RoHS Directive Compatible Filter Blocks ambient light out of blue wavelength range Prevents glare from the light Prevents glare from the light Sharp Cut Filters Blue-light Filter Polarizing Filters Polarizer V44 Series Model Extension Cables Blocks ambient light out of red wavelength range R60 Series R64 Series RoHS Directive Compatible PL Series CB-1 12V FCB 24V CB-2 CB-3 Cable length: 1m Used to connect a 12 V light to a power unit. Mounted on front lens thread to transmit approximately 47% of in a wavelength band centered on 440nm in the wavelength range from 350 to 520 nm. Attaches to the filter screw hole on the camera. Works with a polarizing plate at right to eliminate glare from the light. Attaches to many different lights. Works in combination with the polarizing filter at left to prevent glare. R60-C R60-16 R60-25 R60-27 R60-30 R60-40 R60-46 V44-C V44-25 V44-27 V44-30 V44-40 V44-46 PL-25 PL-25-NL PL-27 PL-27-NL PL-30 PL-30-NL PL-40 PL-40-NL PL-46 PL-LDR-32 PL-LDR-42 PL-LDR-50 PL-LDR2-70* PL-LDR-90 PL-LDR-120-40 PL-SQR-56 PL-LDL-34x8 For C-mount M16.0 P0.5 M25.5 P0.5 M27.0 P0.5 M30.5 P0.5 M40.5 P0.5 M46.0 P0.75 R64-C R64-16 R64-25 R64-27 R64-30 R64-40 R64-46 For C-mount M16.0 P0.5 M25.5 P0.5 M27.0 P0.5 M30.5 P0.5 M40.5 P0.5 M46.0 P0.75 For C-mount M25.5 M27.0 M30.5 M40.5 M46.0 P0.5 P0.5 P0.5 P0.5 P0.75 M25.5 M25.5 M27.0 M27.0 M30.5 M30.5 M40.5 M40.5 M46.0 P0.5 P0.5 (With lock) P0.5 P0.5 (With lock) P0.5 P0.5 (With lock) P0.5 P0.5 (With lock) P0.75 PL-LDL-42x15 PL-LDL-74x27 PL-LDL-82x15 * PL-LDL-130x15 PL-LDL-180x16 * PL-LDL-247x16 * PL-LDQ-78 PL-LDQ-100 PL-LDQ-150 PL-LDQ-200 * PL-LFV2-35 PL-LFV2-50 PL-LFV2-70 PL-LFV2-100 PL-LFV2-130 PL-LFV2-200 Cable length: 5m FCB-1 Cable length: 1m FCB-2 FCB-3 Used to connect a 24V light and an HLV series light to a power supply Light Control Films DF Series CB-W-1 20cm 2-branch CB-W-2 12V CB-W-3 CB-F CB-W-5 * The polarizing plate indicated with '*' comes with a transparent acrylic plate for attaching. FCB-W-1 2-branch FCB-W-2 24V FCB-W-3 CB-F-1 4-branch CB-F-2 12V CB-F-3 FCB-F LC Series CB-F-5 FCB-F-1 Ring type Attaches to the LDR2, LDR2-LA and SQR Series of lights to reduce shine from glossy applications. DF-LDR-32 DF-LDR-42 DF-LDR-50 DF-LDR-70 DF-LDR-90 DF-LDR-120-45 DF-SQR-56 DF-LDR-48LA DF-LDR-74LA DF-LDR-100LA DF-LDR-132LA DF-LDR-170LA DF-LDR-208LA Fixing adapter To install a diffusion plate or polarizing plate Light Adapter Rings AD Series Low-angle type Plastic film arrayed with fine louvers suppresses the diffusion of light in specific directions and improves parallelism. Square type Attaches to the LDQ and LDL Series of bar-type lights to reduce shine from glossy applications. DF-LDL-34x8 (Applicable to LDQ-78) DF-LDL-42x15 (Applicable to LDQ-100A) DF-LDL-74x27 DF-LDL-82x15 (Applicable to LDQ-150A) DF-LDL-130x15 (Applicable to LDQ-200A) DF-LDL-180x16 DF-LDL-247x16 Mounted to back lights to suppress light diffraction for visual inspections, enabling sharp imaging of profiles. LC-LDL-TP-27x27 LC-LFL-100 LC-LDL-TP-43x35 LC-LFL-180 LC-LDL-TP-51x51 LC-LFL-200 LC-LDL-TP-63x60 LC-LDL-TP-83x75 LC-LDL-TP-100x100 Holder Holder Attaches to filter section of lens Secures any type of light Lens Attachment Rings Flexible Arms MR Series FA Series By mounting this on a co-axial light, the parallelism of light is improved and the particularities of a workpiece can be effectively imaged. For LFV2 Series LC-LFV2-35 LC-LFV2-50 LC-LFV2-70 LC-LFV2-100 LC-LFV2-130 LC-LFV2-200 For LFV Series LC-LFV-50 LC-LFV-70 LC-LFV-100 LC-LFV-130 LC-LFV-200 How to use polarizing plates and polarizing filters A polarizing filter and polarizing plate are used in combination. When the polarization direction of the light side and the polarization direction of the camera side differ by 90° (a right angle), regular reflection components of the light are filtered out. 4-branch FCB-F-2 24V FCB-F-3 Cable diameter on power unit side: Ø4.6mm Cable diameter on light unit side: Ø3.0mm(CB)/ Ø3.5mm(FCB) For use with LDR2-32, 42, 50, 90, and 120. This is used for mounting a diffuser panel and a polarizing plate on a light AD-LDR-32 AD-LDR-42 AD-LDR-50 AD-LDR-90 AD-LDR-120 67 Common use for LDR2-32 / LDR-32 Common use for LDR2-42 / LDR-42 Common use for LDR2-50 / LDR-50B Common use for LDR2-90 / LDR-90B Common use for LDR2-120 / LDR-120B For use with LDR2-32, and 50. A light can be directly attached onto the thread for a lens filter using this. Suitable for use in installations in restricted spaces. MR-LDR-32-M25 MR-LDR-32-M27 MR-LDR-32-M30 MR-LDR-50-M25 MR-LDR-50-M27 MR-LDR-50-M30 M25.5 M27.0 M30.5 M25.5 M27.0 M30.5 P0.5 P0.5 P0.5 P0.5 P0.5 P0.5 Holds a 10mm or 12mm rod for light attachment. Can be secured at any angle for easy light adjustment. FA-12 FA-10 Ø12 mm rod Ø10 mm rod Cable length: 5m FCB-F-5 Used to connect 12-V lights to a power unit. One channel for the power unit and two channels for the lights. Branch ends: 20 cmX2. Used to connect 24-V lights to a power unit. One channel for the power unit and two channels for the lights. Branch ends: 20 cmX2. Used to connect 12-V lights to a power unit. One channel for the power unit and four channels for the lights. Branch ends: 20 cmX4. Used to connect 24-V lights to a power unit. One channel for the power unit and four channels for the lights. Branch ends: 20 cm×4. Cable length: 1m Cable length: 2m Cable length: 3m Cable length: 5m Cable length: 1m Cable length: 2m Cable length: 3m Cable length: 5m Cable length: 1m Cable length: 2m Cable length: 3m Cable length: 5m Cable length: 1m Cable length: 2m Cable length: 3m Cable length: 5m * Total power consumption of the connected illuminations should not exceed the output of the power source. In addition, if you wish to set light levels separately for each illumination, use a multi-channel power source. Robot Cables These cables stand up even to a 10 million-repetition bending test. RCB-1 RCB 12V FRCB 24V Cable diameter: Ø4.6mm(RCB)/ Ø4.8mm(FRCB) RCB-2 RCB-3 Cable length: 1m Robot cable to connect a 12-V light to a power unit. Cable length: 2m Cable length: 3m RCB-5 Cable length: 5m FRCB-1 Cable length: 1m FRCB-2 FRCB-3 Robot cable to connect a 24-V light to a power unit. FRCB-5 Cable length: 2m Cable length: 3m Cable length: 5m * When using a robot cable, secure the section of the cable that connects to the light, including the connecter. Cable Dedicated to Fan-equipped Lights These cables support the LFV Series of lights with fans. (Supported power units: PD-3012/3012-2/3024/3024-2/5024, PD2-3012/3012-2/3024/3024-2) CB-FAN-2 10cm CB-FAN Attachment method : (1) Place the polarizing plate on the emitter of the light. (2) Place the polarizing filter on the end of the camera lens. (3) Rotate the polarizing filter until the polarization direction is 90° (a right angle) from the polarization direction of the polarizing plate. Cable length: 3m Use a branch cable when you need to connect several lights to one power unit. FCB-W-5 Diffuser Cable length: 2m Branch Cables Diffusion Plates / Light Control Films Converts diffused light into parallel light Cable length: 3m Cable diameter: Ø4.6 mm(CB) / Ø4.8 mm(FCB) * PL-LDR2-70 comes with an adaptor for installation. Prevents shine and glare Cable length: 2m CB-5 FCB-5 Mounted in front of a lens, R60 blocks light of 600nm or less, and R64 light of 640nm or less, and both transmit approximately 85% of light in wavelength bands longer than these. Description Cables that come with lights are about 30 cm. The following are available as cable extensions. CB PL Series Application 12V FCB-FAN LIGHT FAN Cable diameter on power unit side: Ø5.2mm Cable diameter on light unit side: Ø3.5mm Notes Cable length: 2m FCB-FAN-2 Used to connect a 24-V fan and light to a power unit. FCB-FAN-3 One channel for the power unit (4P connector) and two channels for the light. Branch ends: 10cmX2. FCB-FAN-5 Cable length: 2m CB-FAN-5 LIGHT FAN Used to connect a 12-V fan and light to a power unit. One channel for the power unit (4P connector) and two channels for the light. Branch ends: 10cmX2. CB-FAN-3 24V Cable length: 3m Cable length: 5m Cable length: 3m Cable length: 5m * When you use a cable only for illuminations with fan, light modulation of the power source will be fixed to channel 1. * To use the fan properly, the maximum current must be supplied from the power source. * If you use a single channel power source other than the supported power sources using a normal branch cable with light modulation, it may result in failure. If cables are connected together to form a length of 5 m or more, lighting may become unstable. When using a robot cable, secure the section of the cable that connects to the light, including the connector. 68