HVAC heating repair parts Air Vents 67 75 700C 113222 401488 Float operated 1/8" connection Up to 35 lbs. pressure Vertical mounting Float operated Combo 1/2" I.P. female and 3/4" male connection Up to 150 lbs. pressure Vertical mounting 1/8" connection 150 PSI Max Temp.= 230˚F (110˚C) #97 150 PSI Max temp: 240˚F #79 Vent, Auto Vent, Air Vent, Auto Vent, Air Vent, Water boards 695100 695101 (I.D. #HH84AA020) Time delay timings Heat “ON” 75 sec., Heat “OFF” 105 sec. Cool “OFF” 90 sec. Operating Temp: -40° F to 176° F Max Operating Humidity: 95% R.H. Input Voltage: Terminals; PR-1,PR-2, L1 & L2 - 120 VAC Terminals; SEC-1 & SEC-2 - 18-30 VAC (I.D. #HH84AA021) Time delay timings Heat “ON” 50 sec., Heat “OFF” 80-240 sec. Cool “OFF” 90 sec. Operating Temp: -40° F to 176° F Max Operating Humidity: 95% R.H. Input Voltage: Terminals; PR-1,PR-2, L1 & L2 - 120 VAC Terminals; SEC-1 & SEC-2 - 18-30 VAC Board, Circuit Board, Circuit 5-5⁄16" x 5-1⁄8" 5-1⁄16" x 5-5⁄16" st9120U1011 Board, Electronic Fan Timer Heat Speed ON Delay: Field-adjustable OFF Delay: Field-adjustable Cool Speed ON Delay: Field-adjustable Off Delay: Field-adjustable Ambient Temp °F: -40° to +175° Includes wire harnesses and replaces many of the ST9101, ST9120, ST9141 & ST9160 series timers. capacitors Run Capacitors, Oval CPTO5370 5 uF, 370V CPTO7.5370 7.5 uF, 370V CPTO10370 10 uF, 370V CPTO12.5370 12.5 uF, 370V CPTO70370 70 uF, 370V Perfect for general replacement Other capacitor ratings available 184 Run Capacitors, Round CPTR35370 35 uF, 370V CPTR35440 35 uF, 440V CPTR40440 40 uF, 440V CPTR45440 45 uF, 440V Run Capacitors, Dual/Round CPTR40-5440 40+5 uF, 440V CPTR45-5440 45+5 uF, 440V Perfect for general replacement Other capacitor ratings available current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc controls 5d5178 F560 Control, Fan & Limit 11" element Flush mounting 3/4" diameter element Limit stop set @: 200°F Limit adj. 100°F to 300°F (FALTS57C-05T-120A) Adj. fan off ˚F: 90˚-120˚, Fan on: N/A Limit temp: 150˚-250˚, Limit diff.: 30˚ 7" Manual fan switch allows for continuous fan Manual fan switch allows for continuous fan Flush mounting 3/4" dia. element Limit stop set @: 200°F Limit adj. 100°F to 250°F Control, Fan & Limit Control, Fan & Limit HVAC heating repair parts l4064B2210 11-1/2" element l4064b2228 5" element l4064b2236 8" element Turns the blower on & off as a function of time & temperature Gas Valves VR8200A2132 SV9501M2528 Valve, Dual Combination Gas Valve, Gas 24V, 1/2" x 1/2" Standard Opening Pressure Rating: 1/2 PSI Ambient Temp °F: -40°F to +175°F *Ambient Temp °F: 0°F to +175°F Set at 3.5" WC 24 volt 1/2" x 1/2" Standing pilot Includes reducer bushings Natural to L.P. gas conversion kit Controls include: manual valve, 2 automatic operators, servo pressure regulator and pilot adj. 700402 Valve, Combination Gas 24 Volt Model: 7000BE & 7000BER 240,000 BTUH capacity 3 pos. outlet (FPT): inlet size: 1/2" straight thru: 3/4" side w/ plugs: 1/2" Includes: Extension harness for SmartValve power connector, natural to LP conversion kit 710502 Valve, Combo Millivolt Gas Model: 7000MVRLC 70,000 BTUH capacity 3 pos. outlet (FPT): inlet size: 1/2" straight thru: 1/2" side w/ plugs: 1/2" 720079 Valve, Gas Model: 7200IPER 320,000 BTUH capacity 3 pos. outlet (FPT): inlet size: 1/2" straight thru: 3/4" side w/ plugs: 1/2" Universal Includes reducer bushings, LP adapter plate and built-in regulator set at 3.5" W.C. Includes reducer bushings Has gas regulator set at 3.5" W.C. Designed for recreational vehicles and other low capacity heating applications For intermittent pilot, direct spark and hot surface. Has a compact swing radius of 3-9⁄16" Includes reducer bushings, LP conv. hardware Regulator set at 3.5" natural gas, 11" L.P. 720400 36c03300 36H32304 24V 230,000 BTUH capacity 2 pos. outlet (FPT): inlet size: 1/2" straight thru: 3/4" 24 Volt 140,000 BTUH capacity Fast Opening 3 pos. outlet (FPT): inlet size: 1/2" straight thru: 3/4" side w/ plugs: 1/2" Valve, Dual Combo Gas Model: 7200ER 150,000 BTUH capacity 3 pos. outlet (FPT): inlet size: 1/2" straight thru: 3/4" side w/ plugs: straight thru Includes reducer bushings, LP adapter plate and built-in regulator set at 3.5" W.C. Valve, Combination Gas Regulator setting: Nat. 3.5" W.C. Regulator adj. range nat. gas 2.5"-5.0" W.C. Includes bushing and jumper wire Ideal for general purpose replacement Valve, Redundant Gas Has a swing radius of 3-9⁄16" Regulator adj. range nat. gas 2.5"-5.0 “ W.C. Set at 3.5" W.C. Ambient temp: -40°F to + 175°F Max pressure: 1/2 PSI (14.0" W.C.) Includes reducer bushings, LP conv. hardware Has pilot filter, adj. pilot pressure and manual shut-off valve current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc 185 HVAC heating repair parts igniters 41401 Igniter, Hot Surface Q3400A1024 Igniter, Flame Rod Assembly (ID#: 271A) Ceramic block: 1-5/8" wide Terminal connector: 1/2" wide Lead wire length: 4-1/2" Disconnect on wire ends ceramic Includes spring clip 41402 Igniter, Hot Surface 41403 Igniter, Hot Surface (ID#: 271W) Ceramic block: 1-1/4" wide Stripped wire ends Lead wire length: 19" (ID#: 271) Ceramic block: 2" wide Stripped wire ends Lead wire length: 5-1/8" ceramic ceramic 41404 Igniter, Hot Surface 41405 Igniter, Hot Surface (ID#: 271) Ceramic block: 2" wide Terminal connector: 5/8" wide Lead wire length: 4-1/2" ceramic (ID#: 271D) Ceramic block: 1-1/4" wide Stripped wire ends Lead wire length: 5-1/8" terminal ceramic 41406 Igniter, Hot Surface 41407 Igniter, Hot Surface (ID#: 271Y) Ceramic block: 2-11/16" wide Stripped wire ends Lead wire length: 10-1/2" 41408 Igniter, Hot Surface (ID#: 271N) Ceramic block: 1-1/4" wide Terminal connector: 7/16" wide Lead wire length: 4-1/2" 186 (ID#: 271M) Ceramic block: 2" wide Terminal connector: 1/2" wide Lead wire length: 4-1/2" Includes gasket ceramic ceramic terminal terminal ceramic terminal 41409 Igniter, Hot Surface (ID#: 271) Ceramic block: 2" wide Terminal connector: 5/8" wide Lead wire length: 4-1/2" ceramic terminal current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc Includes gasket igniters 41411 Igniter, Hot Surface (ID#: 271N) Ceramic block: 1-1/4" wide Terminal connector: 1/2" wide Lead wire length: 4-1/2" ceramic (ID#: 271N) Ceramic block: 1-1/4" wide Terminal connector: 7/16" wide Lead wire length: 4-1/2" terminal ceramic 41412 Igniter, Hot Surface terminal 411090 Igniter, Hot Surface (ID#: 271) Ceramic block: 1-1/4" wide Terminal connector: 5/8" wide Lead wire length: 4-1/2" ceramic HVAC heating repair parts 41410 Igniter, Hot Surface Ceramic block: 1" wide Stripped wire ends Lead wire length: 13-3/4" terminal ceramic PLT3400 Igniter, Hot Surface 1096048 Igniter, Retro-Fit Boiler Ceramic block: 2-11/16" wide Terminal connector: .250" male insulated Lead wire length: 12" Terminal connector: 5/8" wide Lead wire length: 5-1/4" terminal Lochinvar igniter Includes mounting brackets 902661 Igniter, Round Boiler Turn to the next page for an igniter cross reference and trouble shooting guide. Lead wire length: 9" Nordyne igniter Includes two quick disconnects PDQ also carries HVAC BELTS call today 800.843.0903 FHP V-Belt Deep Wedge Multi-Cogged Multi-Plus V-Belt Raw Edged Cogged current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc 187 HVAC heating repair parts igniters CROSS REFERENCE Amana * The OEM’s used a wide variety of terminal connector types, therefore, all Robertshaw/ Norton 41 Series functional replacement ignitors include ceramic wire connectors. + May have exact O.E.M. terminal connector. OEM Am. Appliance OEM Part # Part # Funct. x OEM Norton (cont) OEM Part # Part # 271P 41-405 271M 41-406 Exact Funct. + x* + x* 41-401 D99182 41-401 x 10041601 41-401 x 271N 41-402 x* 271B 41-406 x 271W 41-402 x* 271Y 41-406 + x* Am. Road Equip. 201W 41-402 x Armstrong Air 38322B001 41-402 x Perfection Schwank 108803-G1 41-406 x Carrier Corp. Claire Brothers LH33ZS004 41-409 600915 41-403 x C-238 41-402 x Raypak Rheem 62-22441-01 41-408 x C-242 41-402 x 62-22441-01 41-402 1474-051 41-402 x 62-22868-82 41-411 904034300 41-409 90436600 41-402 50018 41-405 x 1380672 41-409 x 1380680 41-409 x 1380654 41-403 x 94851 41-402 x B138196P02 41-403 B144676P01 41-410 x B144676P02 41-407 x B340039P01 41-408 x Coleman x 1474-052 41-402 x Comfort Zone 015114-04-01 41-406 x Detroit Radiant 201D 41-405 x Roberts Gordon Smith HB Snyder General DMO Industries 20834 41-405 x Dornback Furnace 271W 41-402 x Ducane 20015201 41-409 Enerco Evcon 10399 41-402 x 1474-051 41-402 x 1474-052 41-402 x B1401009 41-412 09050 41-402 1009604 41-412 x 340039P01 41-402 PLT2400 41-406 x IGN23 41-402 75-92-104 41-402 x IGN26 41-409 75-92-105 41-402 x IGN26 41-403 201N 41-402 x IGN30 41-407 x IGN30 41-403 IGN34 41-408 Goodman Hupp Industries Intercity Lochinvar Corp. Majestic Metzger Mor-Flo Nordyne Norton TROUBLESHOOTING CHART 201W 41-402 3200580 41-406 x x x x Trinco-Heatmaker 41-401 x 41-405 x 105141000 41-402 x Viessman 9302-094 Wayne Home Equip. 62821-001 632-0880 41-402 x 62821-002 41-402 632-0770 41-402 x 511-330-139 41-409 x x Weil-McLain 2600-359 x x x 41-402 201 41-403 x* 511-330-188 41-406 201A 41-401 x* 511-330-193 41-403 201D 41-405 + x* 511-330-190 41-404 201J 41-406 + 201K 41-402 x* x* 201L 41-402 201M 41-406 x 201N 41-406 x 201R 41-402 x* 201W 41-402 x* White L.B. Compay 120-07549 White Rodgers 767A-309 x* x* Williamson York International x x x x 41-402 41-401 x x 767A-356 41-401 x 767A-361 41-405 x 767A-357 41-402 x 09050 41-402 x 025-27766-000 41-405 x x 201Y 41-406 x* 025-27774-000 41-405 271 41-403 x* 025-29043-000 41-405 x 271A 41-401 x* 025-29050-000 041-405 x NO + Failure to read and follow all instructions carefully, before installation or operating this control, could cause personal injury and/or property damage. Confirm 24VAC between “TR” & “TH” terminals on ignition module. Confirm Transformer output; if NO, replace. Confirm wiring integrity. Confirm proper voltage between L1 & L2. Confirm proper voltage to ignitor. If YES, replace ignitor. If NO, replace control. NO Confirm proper L1 & L2 phasing (polarity). Confirm proper voltage (24VAC) at gas valve. If NO, replace ignition control. Confirm proper ignitor position. If OK, replace gas valve. NO Confirm proper L1 & L2 phasing (polarity). Confirm proper ignition control grounding. Confirm proper ignitor position. If OK, replace ignition control. yes yes end troubleshooting x x x yes yes x x 41-402 during heat-up time ignitor glows red call for heat ends, burner shuts off x x 41-406 yes main burner remains lit Superior Fireplace Trane Company x 3200618 Set thermostat to call for heat after ignitor heat-up time main burner lights x x x 3210401 WARNING start 188 Exact B1336102 NO Confirm zero (0) VAC at “valve” terminal on ignition control. Confirm integrity of thermostat. Check voltage at main valve. If zero (0) VAC, replace gas valve. If 24VAC, replace ignition control. current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc igniters HVAC heating repair parts TROUBLESHOOTING CHART HOT SURFACE OPERATION On a typical heating system with hot surface ignition, a call for heat (thermostat contacts closed) will send a 24 volt signal to the Robertshaw ignitor module. When energized, the module will power-up the ignitor within one second. If the module is a pre-purge model, it will delay 17 or 34 seconds before the ignitor is activated. On pre-purge models, the module will energize the combustion blower or other relays at the beginning of the cycle. Once the pre-purge timing is up (if so equipped), the silicon carbide ignitor heats up to proper ignition temperature in either 17 or 34 seconds, depending on the module part number. NOTE: A 17 second ignitor can be used on a 34 second application but not the other way around. See 41-400 series for Robertshaw’s replacement ignitors. At the end of the ignitor warm-up period, the gas valve main valve opens. The ignitor will remain on for a specific amount of time (seconds) depending on the specific ignition module being used. This “ON” time or “valve trial time” could be 4, 6, 8, or 12 seconds. When main burner ignition occurs, the flame is sensed by the ignitor (local sense) or by a remote sensor (remote sense). With main burner flame established, the ignitor is turned off. NOTE: The burner flame must be detected within the valve trial time. If no flame is detected, the gas valve main valve is de-energized, shutting off the gas flow. PROBLEM #1 - HOT SURFACE IGNITOR DOES NOT GLOW RED (Remember to wait for purge time, 17/34 seconds, on models so equipped) Possible causes A. No main power B. Faulty transformer C. Faulty thermostat D. Faulty limit switch E. Faulty blower interlock switch F. Faulty ignition control Solution Step #1 Perform normal system checks of main power, transformer, thermostat, limit switch, blower interlock switch, and replace faulty component. Step #2 With power on and thermostat set at its highest position, check voltage between “TH” and “TR” on HS780 ignitor control. If 24 volts is not present check output at transformer. If no, replace transformer. If transformer checks out OK look at other controls in the 24 volt circuit I.E.: thermostat, limit switch, blower interlock switch. Check for 120 volts between “NEUT” (L2) and “120” (L1). Check for 120 volts at the ignitor across “IGN” and “IGN” terminals on the HS780 ignitor module. If 120 volts is present, replace ignitor. If no, replace the 780 series module. CAUTION POLARITY MUST BE OBSERVED Step #5 Check for 24 volts at the gas valve terminals; “1” and “2” on a 7200 series, “M” and “C” on a 7100 series, “TH” and “TR” on a 7000 series. If yes, check wire integrity or change the gas valve. If no, change the 780 series ignition module. PROBLEM #3 - MAIN BURNER SHUTS OFF BEFORE THE THERMOSTAT IS SATISFIED Possible causes A. Improper ignitor alignment B. Faulty ignition control C. Contaminated ignitor and/or sensor(remote sense) D. Bad burner ground Solution Step #1 Check proper polarity of “NEUT” and “120” on the ignition control by reversing the wires. If this does not solve the problem, replace the wires as they were. Step #2 Check for proper ignitor position. Step #3 PROBLEM #2 - IGNITOR GLOWS RED BUT MAIN BURNER WOULDN’T LIGHT Check for proper ignition control grounding. Step #4 Possible causes Visually inspect the ignitor and/or the remote sensor for any contamiA. Improper ignitor alignment nation or other foreign matter that might keep either unit from sensing B. Faulty ignition control main burner flame. Clean or replace. C. Faulty gas valve Step #5 D. High inlet gas pressure Check main burner ground by checking for continuity between “TR” E. Polarity reversed and burner. If a poor reading is obtained, take corrective action. F. No earth ground Step #6 Solution If steps 1 thru 5 are OK, replace ignition control. Step #1 PROBLEM #4 - MAIN BURNER DOES NOT SHUT OFF WHEN THE Check for availability of gas valve. Make sure the manual valve upstream THERMOSTAT IS SATISFIED of the gas valve and the gas valve are in the full on position. Also make Possible causes sure gas is being supplied to the system at the proper pressure, too high A. Faulty gas valve will lock-up the valve. B. Faulty ignition control Step #2 Check proper polarity of “NEUT” and “120” on the ignition control by revers- Solution ing the wires, if reversed gas valve will not open. If this does not solve the Step #1 Check thermostat to make sure the contacts are open, check for 24 problem, replace wires as they were. volts between “TH” and “TR”. Should be zero, if gas valve is stuck Step #3 open, replace the valve. Check proper ignitor position. Step #2 Step #4 Check for voltage between “valve” and “ground” on the ignition control. Check for a good earth ground by using a meter connected between L1 If 24 volts are present replace ignition control. If there is no voltage, and furnace chassis. Should read 120 volts, if no, check and/or repair replace gas valve. ignition ground ie: ground wire or ignition control mounting screws. current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc 189 HVAC heating repair parts Modules - motors 780715 780783 (Model: SP715/USI715U) Non-lockout Input voltage: 24VAC Max. current load: 1.5A Flame rectification system (Model: HS780-34PL-308-A) Hot surface ignition Lockout Input voltage: 24VAC Max. current load: 1.5A Prepurge: 34 sec. Ignition attempts: 3 Module, Ignition Module, Ignition Used with gas valve models: 7000BDER & 7100DER s8610u1003PDQ S8610U3009 Intermittent ignition Retry: 5 min. Ignition Trial: 90 sec. Intermittent ignition Retry: continuous Prepurge: 0 or 30 sec. Ignition Trial: 15 or 90 sec. Module, Ignition Module, Ignition Universal Universal For use in direct spark ignition systems Replaces over 300 existing IP modules Can be used on single/dual rod systems Capable Controls version of Honeywell’s S8610U1003 For use in direct spark ignition systems Replaces over 300 existing IP modules Can be used on single/dual rod flame sensing Honeywell’s replacement for the S8610U1003 s8910u1000 50A55843 Hot surface ignition 4 or 7 sec. lockout Hot surface ignition Input voltage: 25VAC Prepurge: 0 sec. Ignition trial: 7 sec Module, Ignition Module, Ignition Universal Provides 1-3 trials for ignition Replaces over 100 HSI modules For use in hot surface ignition systems to control hot surface ignitor and flow of gas in appliances 50E47843 EM670 Replaces all White Rodgers and virtually all competitive Carbide Non-Integrated modules Input voltage: 25VAC 60 Hz, 120 VAC, .55 AMP CW/CCW rotation, 3000 RPM Shaft: 1-1/4" length, 3/16" dia. Stack Thickness: 5/8" C-frame, shaded pole Module, Ignition Motor, Replacement Kit Replaces: GEM EM670, ACME AM-4670, SUPCO SM-670, MARS90971 Used on refrigerators, freezers, condenser fans, vending machines, vent hoods, exhaust fans and ventilators EM673 Motor, Replacement Kit Replaces: 50E47-50, 50E47-150, 50E47-834, 50E47-70 6 different program keys with corresponding color coded timing labels. Program key determines… trial for ignition, retries, prepurge and warm-up time 190 60 Hz, 120 VAC, .55/.34 AMP CW/CCW rotation, 3000/1550 RPM Shaft: 1-1/4" length, 3/16" dia. Stack Thickness: 5/8" C-frame, shaded pole Replaces: GEM EM673 Used on refrigerators, freezers, condenser fans, vending machines, vent hoods, exhaust fans and ventilators current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc Pilot - Ptac Parts SRC601 WP23X94 Kit, Heat Coil Fuse PTAC Pilot, Burner PTAC 5,000 watts ZONELINE® Nonprimary-aerated, insert orifice-type pilot burner for main burner ignition. For use with Q340 or Q390 thermocouples for Pilotstat safety control operation. Use with Q313 Thermopile Generator for 750mv Powerpile applications. CER100 WP12X9 Insulator, Ceramic Knob PTAC PTAC 1/2" extended shaft “D” position when knob is viewed from back in OFF position. ZONELINE® WP12X10002 PTAC Knob 5/8" extended shaft wrapped w/ foam strip “D” position when knob is viewed from back in OFF position. .250" Used on old Singer models .250" WJ73X10037 24A341 B1370738 Propeller Sequencer Sequencer PTAC PTAC SPST On: 1-20 sec. Off: 40-110 sec. 13-3/4" dia. ZONELINE® PTAC 24V ZONELINE® Has (8) .250" male terminals Has (7) .250" male terminals Used on Goodman air handlers 90293Q 90370 620403 Relay, Fan Relay, Fan Transformer PTAC PTAC 250V 8 amp 18FLA 18LRA 12FLA @ 125V 8FLA @ 250V Has (5) .250" male terminals PTAC Primary: 120V Secondary: 24V Capacity: 40VA Has (5) .250" male terminals RSKP0009 Kit, PTAC Control Board This kit is designed for PTAC units that use 208/230V Kit includes: board, control panel, transformer, wire enclosure, 4 thermistors with color coded leads, 14-pin and 18-pin female housings, 18 jumper wires, 18 wire nuts, 2 screws, and 2 clips current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc 191 HVAC heating repair parts q314a4586 HVAC heating repair parts Pumps Armstrong special order, non-stock item With variations in size, capacity, voltage & horsepower, there are numerous stock sizes available for quick shipment. When inquiring about complete pumps or replacement parts, please have all name plate data ready when you call. Circulators, Astro Series Fluid Lubricants Applications include hydronic heating, chilled water, domestic hot water recirculation, heat recovery and solar heating Model Const. Astro 30 Astro 30B Astro 50 Astro 50B Cast Iron All Bronze Cast Iron All Bronze Input Watts Full Load H L overall W L1 L2 L3 C Weight Amps in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 80 .70 110 .82 Maximum Working Temp: 6-3/8 (162) 7 (178) 2-5/8 (67) 4-1/2 (114) 5-1/8 (130) 2-1/8 (54) 3-1/8 (79) 10 (22) 230˚F (110˚C) Maximum Working Pressure: 140 psi (965 kPa) Replacement Cartridge Design • Efficient/Quiet Operation • Universal Flange to Flange Dimension Cast Iron or All Bronze Construction • CSA/UL Listed Circulator Circulators, Series S & H In-Line Model Flange Size (NPT) HP S-25 3/4" 1" 1-1/4" 1-1-2" 1/12 S-35 2" 1/6 S-45 2-1/2", 3" 1/4 S-46 3" 1/3 S-55 3" 1/2 S-57 3" 3/4 S-69 3" 1 H-32 1", 1-1/4" 1/6 H-41 1" 1/6 H-51 1-1/2" 1/4 H-53 1" 1/2 H-54 2" 3/4 H-68 2" 1-1/2 A Order Number 3/4 (19.05) Directly Replaces Taco # 174031-013 1ph 174031-043 1ph 110 7/8 (22.225) 1 (25.4) 1 (25.4) 1 (25.4) 1 (25.4) 1 (25.4) 7/8 (22.225) 3/4 (19.05) 3/4 (19.05) 7/8 (22.225) 7/8 (22.225) 7/8 (22.225) 174033-013 1ph 174033-043 1ph 121 174036-113 1ph 174036-143 1ph 121 Dimensions: inches (mm) B C D 13-3/4 (349.25) 6-1/2 (165.1) 11-1/2 (292.1) 15 (381) 15-3/4 (400.05) 15-3/4 (400.05) 19-1/2 (495.3) 10 (254) 25 (635) 15 (381) 15-1/4 (387.35) 17-1/4 (438.15) 20 (508) 20 (508) 21-3/4 (552.45) 8-1/2 (215.9) 10 (254) 10 (254) 12 (304.8) 12 (304.8) 14-1/4 (361.95) 8-1/2 (215.9) 8-1/2 (215.9) 11-1/2 (292.1) 11-1/2 (292.1) 11-1/2 (292) 14 (355.6) 12-1/2 (317.5) 12-1/2 (317.5) 12-1/2 (317.5) 16 (406.4) 16-1/2 (419.1) 20-1/4 (514.35) 12-1/2 (317.5) 12-1/2 (317.5) 13-1/2 (342.9) 16-1/2 (419.1) 16-1/2 (419.1) 18-1/4 (463.55) Bronze Fitted All Bronze 174037-113 1ph 174037-143 1ph 106284-132 1ph 106284-136 3ph 106285-132 1ph 106285-136 3ph 116531-132 1ph 116535-136 3ph 106284-133 1ph 106284-137 3ph 106285-133 1ph 106285-137 3ph 116532-133 1ph 116536-137 3ph 131 132 133 – 174034-013 1ph 174034-043 1ph 111 174035-113 1ph 174035-143 1ph 113 116431-132 1ph 116432-133 1ph 1600 116439-132 1ph 116440-133 1ph 1612 116451-132 1ph 116452-133 1ph 1632 116523-136 1ph 116524-137 1ph 1636 Applications include hydronic heating and cooling, domestic water systems, multi-stage zoning and general industrial service Seal/Bearing Assembly with Interchangeable Shaft Module 2 series 3 series 4 series 5 series 192 Model Converesion Assembly S-25 3/4 S25 1 S-25 1-1/4 S-25 1-1/2 Universal 810119-001 S-35 H-32 1 H-32 1-1/4 H-32 1-1/2 Universal 816549-091 S-45 2-1/2 S-45 3 S-46 H-41 Universal 816027-002 S-55 S-57 H-51 H-52 H-53 H-54 Universal 816032-000 Shaft Module 816999-041 current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc bell & gossett Circulators, Bronze Bodied System Lubricated part# 103257 103258 103259 103261 103260 103316 103255 103252 Model# Connection HVAC heating repair parts With variations in size, capacity, voltage & horsepower, there are numerous stock sizes available for quick shipment. When inquiring about complete pumps or replacement parts, please have all name plate data ready when you call. Pumps Watts RPM NBF-8S/LW 1/2" Sweat 39 2800 NBF-9U/LW Union 412800 NBF-10S/LW 1/2" Sweat 52 2800 NBF-12U/LWUnion 552800 NBF-12F/LWFlange 3/4", 1", 1-1/4", 1-1/2" 55 2800 NBF-18S 1/2" Sweat 90 3000 NBF-22U Union 922940 NBF-22FFlange 3/4", 1", 1-1/4", 1-1/2"92 2940 103417 106189 Flanges 3/4" 1" 1-1/4" Model: 100-BNFI, const: bronze, 115V, 1/12 HP 1-1/2" Model: 100-NFI, const: iron, 115V, 1/12 HP Pump, 3-Speed Wet Rotor Circulator 106197 Pump, Standard Booster Motor: NRF-25, 115V Max working press: 150 PSI Max operating temp: 225˚ F 102210 Pump, High Velocity Booster Maintenance free Quiet operation For residential or light commercial hydronic systems Shipped without the piping flanges & check valve. Model: HV NFI, const: iron, 115V, 1/6 HP Shipped without the piping flanges. If required, order them from the chart…. 103251 Iron 101001 101002 101003 101004 Bronze 101011 101012 101013 101014 Flanges Iron Bronze 1" 101005 101015 1-1/4" 101006 101016 1-1/2" 101007 101017 106507 Model: NRF-22, Const: iron Pump, Little Red Booster 103260 115V, 1/20 HP Model: LR 20 BF Construction: iron Model: NBF-12, Const: bronze Pump, “Red Fox” 115V, 1/25 HP Flanges 3/4" 1" 1-1/4" 1-1/2" Iron 101001 101002 101003 101004 Bronze 101011 101012 101013 101014 Compact size, lightweight, single speed motor, standard flange to flange dimensions. Shipped without the piping flanges. If required, order them from the chart…. bell & gossett Assembly, Bearing Order # Iron 118844 185011 185260 186863 186865 189105 189134 189162 189163 189165 Bronze 189034 189165 *LCAC Used with Pump BF BF BF BF AI BF BF IB AB IB AB IB AB Series 100 1510 series - 1" shaft pd 38, pd 39, pd 40 1522 3/4" aab thru 1-1/2" aab 1522 3/4" aab thru 1-1/2" aab 1" pr, 2-1/2", ld 3", hd 3" Series 100- includes impeller 1", 1-1/4", 1-1/2" 2-1/2" 2" & hv 2" & HV NFI, 2" & HV bnfi, 2" & HV AB IB Series 100 Small dia. (5") 2", HV * Liquid Contact Area Construction AB- all bronze, AI- all iron, BF- bronze fitted, IB- iron body Body Gasket Nut Seal Kit Oil Wicks Lockwasher Flanges 3/4" 1" 1-1/4" 1-1/2" Iron 101001 101002 101003 101004 Bronze 101011 101012 101013 101014 Pump Repair parts 185332LF Assembly, Bearing Front Bearing Key Shaft Bracket Oil Well Cover Front Bearing Screw MORE Compact size, lightweight, single speed motor, standard flange to flange dimensions. Also available in union connections. Shipped without the piping flanges. If required, order them from the chart…. Maintenance free For use on B&G maintenance free Series 60 pumps sizes: 1" x 1" x 5-1/4" 1-1/4" x 1-1/4" x 5-1/4" 1-1/2" x 1-1/2" x 5-1/4" 2" x 2" x 5-1/4" Adapter ring gasket #P58542 must be ordered on all pumps sizes — x — x 6-1/4" current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc 193 HVAC heating repair parts Pump Repair parts bell & gossett 118368 Couplers Gasket, Flange Shaft Dia. Order # 118473 118705 118708 118709 118723 186410 189110* Motor Pump 1/2" 1/2" Series 100 prior to 4/91 Used with Pump pd 35, pd 37, 60aa, 1522 1/2" 1/2" 3/4" 1/2" Series 100, HV, PR, 1", 1-1/4", 1-1/2", 2" pd 35, pd 37, 60aa, 1522 5/8" 1/2" pd 35, pd 37, 60aa, 1522 1/2" 1/2" 2-1/2", ld 3", hd 3", hld 3", hhd 3" 1/2" 5/8" 60a, 1/2" 1/2" Series 100, HV, PR, 1", 1-1/4", 1-1/2", 2" * Pressed steel Pumps after date code D19 (4/91) use a flat, full face, two bolt hole gasket. As the gasket part numbers were not changed, specify “ring” or “flat” when ordering. Gaskets, Pump Body Order # Cast iron spring type except where noted important! Coupler breakage is usually caused by sagging motor mounts. Protect your pump from premature failure. Always replace both the coupler and the resilient motor mounts. P04080 P04890 P05800 P48690 P57410 P57700 O.D. Used with Pump 3-1/8" Series 100 3-7/8" 1" thru 2-1/2", HV, 3" HLD & HHD 4-3/4" pr, 2-1/2", ld 3", hd 3" 11-1/2" 1510b & bb, 1531 5-5/8" pd 35 to 37, 60aa, 1522, 1535 7-7/8" pd 38 to 40, 60a, 1510a 111031 189132 1/6 HP, Used with: PR, & pumps w/ 6" dia. bearing assemblies: #189100 to #189106 Impeller 111034 1/12 HP Used with: Series 100 1-7/8" 111040 1/4 HP Used with: 2-1/2", LD 3 111042 2-3/4" 2-piece, non-ferrous Used with Series 100 NFI, 100 BNFI boosters Replaces Armstrong #812961-111 l23401 1/3 HP Used with: HD 3 111061 1/6 HP Used with: 2" NFI, 2" BNFI, HVNFI, (5" dia) HVBNFI 169035 1/4 HP Used with: 60 1" AA, 60 1-1/4" AA Motor, Pump 115V, 1725 RPM 17076 Oiler, Zoom Spout Oil, Lubricant 4 oz. 1-1/2 oz. SAE-20 mineral oil in plastic squeeze tube marked with proper amounts for oil cups on motors and bearing assemblies 117412LF CB-1/2S, FSWT 117413LF CB-3/4S, FSWT 117401LF CB-1S, FSWT 117415LF CB-3/4, FNPT 117416LF CB-1, FNPT 118223 Used with HP: 1/12, 1/6 118228 Used with HP: 1/3, 1/4, 1/2, 3/4 Rings, Motor Mounting Resilient High grade turbine oil lubricant Has a 14" telescoping spout which enables you to access those hard-to-reach areas Balance valve for both potable water & HVAC systems Externally adjustable manual balance valve for easy adjustment Positive shut-off service Bi-directional design allows any installation configuration Reduces pump energy requirements Meets or exceeds stringent codes for potable water Sold in sets of two 118395 p04883 Wicking Set, Oil Valves, Circuit Setter LF= lead free (contains less than 0.25% lead content by weight on wetted surfaces) 194 current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc Pumps TACO 110 Pump, “00” Series Cartridge Circulator Pump, 110 Series Circulator 115V, 1/25 HP, 3250 RPM Capacity: 11" to 20 GPM Construction: iron Flanges: 3/4", 1", 1-1/4", 1-1/2" (companion flanges not included) 115/60/1 V, 1/12 HP, 1725 RPM Capacity: 7' to 35 GPM Construction: iron Flanges: 3/4", 1", 1-1/4", 1-1/2" Larger capacities available, call for pricing Compact, quiet & lightweight System water lubricated- never requires oiling Standard universal flange dimensions Replaceable cartridge rebuilds the pump 1600C Cast iron bronze fitted 1600B All bronze Pump, 1600 Series In-Line 115/60/1 V, 1/4 HP Capacity: 20' to 55 GPM Flanges: 1-1/2" Quiet & dependable Proven performance- residential & light commercial systems Available in bronze construction for domestic hot water systems Casting: Cast iron or bronze “in-line” construction. Permits line mounting in vertical or horizontal run of pipe. Pressure rating to 175 psi. Motor: Resilient mounted, drip proof sleeve bearing motor especially selected for quite operation Maintenance: Low maintenance costs are Coupler: Non-metallic sound deadening cou- assured due to parts flexibility. One bearpler parts flexibility. One bearing assembly ing assembly (cartridge) and one seal fit all (cartridge) and one seal fit all models from models from 1/4 - 3 H.P. 1/4 - 3 H.P. Taco Parts, Replacements for 110-120 Circulators Order # 110275RP 110223RP 110185RP 110361RP 111058RP 120067RP 110009RP 110127RP HVAC heating repair parts 007F Part Used on Pump Seal All 110 to 120-12 Motor HC, 110, 117 Motor HDH, 111, 113 Bearing assembly HC, 110, 117 Bearing assembly HDH, 111 Bearing assembly 120-6 to 120-12 Coupler All 110 to 120-12 Gasket Kit 110 to 113 Pump Repair parts Parts, Replacements for 110-120 Circulators Order # 1600868CRP 121151RP 131143RP 132096RP 1624053RP 1600160RP 1600050RP Part Used on Pump Seal 1600 cartridge design Motor 1/4 HP (115/60/1) Motor 1/3 HP (115/60/1) Motor 1/2 HP (115/230/60/1) Coupler All in-line pumps 1/4 - 1 HP Cartridge All -9, serial # pumps Gasket Kit All -9, serial # pumps Relays l8148E1265 l8148j1009 Immersion type controller combines high limit protection with switching relay control of burner and circulator circuits Control circuit: 24VAC, 60Hz Burner circuit: 24VAC, 60Hz Circulator circuit: 120V, 60 Hz, 7.4 AFL Well adapter and heat-conductive compound included Vertical or horizontal mounting Immersion well only: #121371A (1/2"), #121371B (3/4") Immersion type controller combines high limit protection with switching relay control of burner and circulator circuits Control circuit: 24VAC, 60Hz Burner circuit: 24VAC, 60Hz or millivolt High Limit range: 140° to 240°F (60° to 116°C) Well adapter and heat-conductive compound included Vertical or horizontal mounting Immersion well not included Immersion well only: #121371A (1/2"), #121371B (3/4") Relay, Aquastat current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc MORE Relay, Aquastat 195 HVAC heating repair parts relays RA89A1074 RA832A1066 SPST DPST Relay, Hydronic Switching Relay, Hydronic Switching Control circuit: two-wire low voltage Resistive rating: 120VAC, 10; 240VAC, 6A Used to switch 1 line voltage loads Permit a low voltage controller or thermostat to control a line voltage device Built-in transformer provides 24VAC power for the control circuit Control circuit: two-wire low voltage Resistive rating: 120VAC, 10; 240VAC, 6A Used to switch 2 line voltage loads Permit a low voltage controller or thermostat to control a line voltage device Built-in transformer provides 24VAC power for the control circuit 90293q R8222d1014 DPDT Relay, Switching SPDT Relay, Switching 24V Temp range: -40˚F – +150˚F RBM type 84 Ind. amps @ 250V: 8 cont. Inrush. amps @ 250V: 25 24Volt 277VAC: 15 Amp resistive 480VAC: 10 Amp resistive Dimensions: 1-7/8"H x 2-5/32"W x 2-3/8"D Base designed for easy replacement Untaped coil assures cooler operation and is less likely to trap moisture thermocouples q340a1066 q340a1074 q340a1082 q340a1090 18" 24" 30" 36" Thermocouple q390a1095 q390a1046 q390a1053 q390a1061 18" 24" 30" 36" Thermocouple Includes adapter bag assembly, 5 clips & 5 sleeves 1950001 1970018 1970024 1970030 1970036 18" 24" 30" 36" Uni-Couple® The 1970 series unique design allows for easy installation to most pilot burners. The versatile zip nut may be pulled, pushed or even threaded onto the Uni-couple’s rolled threads for proper positioning in every application. 1950532 k19at18 k19at24 k19at36 Thermopile, 750 Millivolt (Universal Replacement) 36" (includes PG9 adapter) 36" (less PG9 adapter) 24" 36" Thermocouple, Super Slim Jim™ The 1950 thermopiles (pilot generators) are designed for use on self-powered gas control systems. They can be used to replace all Robertshaw & similar competitive devices. 196 18" 1980018 1980024 1980030 1980036 18" 24" 30" 36" Thermocouple, Snap-Fit® With its snap-fit adapter, the 1980 series is the simplest replacement thermocouple available today k15ds18 k15ds24 18" 24" Thermocouple, Standard Baso This popular thermocouple is used for Baso, Basoid, Basotrol valves & switches current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc thermostats q539a1014 Stop, Range HVAC heating repair parts 50010944001 Subbase, Thermostat Fan switch: On-Auto System switch: Cool-Off-Heat or Off-Heat Used with T87 to limit temperature to 75˚ Includes 2 set screws, 1 F and 1 C range stop Provides system and fan switching and mounting for Honeywell T87F thermostats. 490400 T87N1000 Universal Heating/Cooling Fan switch: On-Auto System switch: Heat-Off-Cool Temp. range: 40˚F – 90˚F 24Volt- Heating/Cooling System switch: Heat-Off-Cool Fan switch: Auto-On White Thermostat, Wall MERCURY FREE For use with: Robertshaw 400/405 Series & 450/455 Series thermostats Replaces #’s: T87F1859, T87F2790, T87F2873 Used w/: gas, oil or electric heat with air conditioning, warm air, hot water, high-efficency furnaces, heat pumps, steam, gravity Uses coverplate #50000066-001 T87K1007 T87N1026 White Thermostat, Wall MERCURY FREE Temp. range: 40˚F – 90˚F 24Volt- Heating White Thermostat, Wall (Easy-to-See) Temp. range: 40˚F – 90˚F 24 Volt- Heating/Cooling System switch: Heat-Off-Cool Fan switch: Auto-On Replaces #’s: T87F1859, T87F2360, T87F2782, T87F2790, T87F2816, T87F2873 Use with gas or oil heat Heat only, 2-wire and 3-wire hot-water valve Replaces #’s: T87F3467, T87F5199 Used with: gas, oil or electric heat with air conditioning, warm air, hot water, high-efficency furnaces, heat pumps, steam, gravity T834N1002 T822K1018 White Thermostat, Wall Temp. range: 50˚F – 90˚F Low Voltage 24 Volt- Heating/Cooling System switch: Heat-Off-Cool Fan switch: Auto-On White Thermostat, Wall MERCURY FREE Temp. range: 50˚F – 90˚F Low Voltage 24 Volt- Heating Replaces #: T834C1137 For use with gas, oil, electric, heat pump, forced warm air, hot water, steam or gravity For use with gas, oil, forced warm air, hot water, steam or gravity t410a1013 t410B1004 White Thermostat, Wall Temp range: 40˚F – 80˚F SPST switch action Line Voltage Electric rating: 19A @ 277 Volt, 22A @ 120/208/240 Volt Suitable for electric heat MERCURY FREE White Thermostat, Wall Temp range: 40˚F – 80˚F DPST switch action Line Voltage Electric rating: 19A @ 277 Volt, 22A @ 120/208/240 Volt MORE Subbase, Thermostat Suitable for electric heat current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc 197 HVAC heating repair parts thermostats T498B1512 T651A3018 Beige Thermostat, Wall Thermostat, Wall Temp range: 44˚F – 86˚F Heating/Cooling SPDT switch action Line Voltage Electric rating: 9.8A @ 120V Temp range: 40˚F – 80˚F Line Voltage Electric rating: 19A @ 277V, 22A @ 120/208/240V Suitable for electric heat Has thermometer, temperature range stops, locking cover and recalibration decal TH5220D1003 SC1001 Horizontal mount SC1001V Vertical mount White Thermostat, Wall Thermostat, Wall Temp. range: 40˚F – 90˚F Digital, Non-programmable System switch: Heat-Cool-Auto-Off-EmHeat Fan switch: Auto-On Non-programmable Single stage- heat/cool or heat pump White Includes (2) AA batteries for display window ICM patented thermal intrusion barrier Used on gas, oil & electric systems SC2000N Battery powered SC2001N Hardwired SC1600 Battery powered SC1601 Hardwired Non-programmable Single stage- heat/cool or heat pump White Non-programmable Single stage- heat only, no fan switch White Thermostat, Wall Thermostat, Wall MERCURY FREE MERCURY FREE ICM patented thermal intrusion barrier Used on gas, oil & electric systems ICM patented thermal intrusion barrier Used on gas, oil & hydronic systems SC3000N Battery powered SC3001N Hardwired 200401 Beige Thermostat, Wall Thermostat, Wall MERCURY FREE Temp range: 48˚F – 86˚F Low Voltage 24 Volt- Heating 2 Wire 7 day programmable Heat/cool or single stage heat pump White MERCURY FREE ICM patented thermal intrusion barrier Used on gas, oil & electric systems Decorative wall plate is included 9200H White 9204H Thermostat, Wall Temp range: 50˚F – 90˚F 24V - Heating/Cooling Low voltage Includes subbase Heavy-duty heat anticipator For use with gas, oil or electric heating/cooling systems 198 MERCURY FREE White Thermostat, Wall MERCURY FREE Temp range: 50˚F – 90˚F 24 Volt- Heating Low voltage Includes subbase Heavy-duty heat anticipator For use with gas, oil or electric heating/cooling systems current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc thermostats White 1E30N910 MERCURY FREE Thermostat, Wall White HVAC heating repair parts 9204v Thermostat, Wall Temp range: 50˚F – 90˚F Low Voltage Includes Subbase 24 Volt- Heating Temp range: 50˚F – 90˚F Low Voltage - White 24 Volt- Heating MERCURY FREE Heavy-duty heat anticipator For use with gas, oil or electric heating/cooling systems 1E56N444 White 1F56N444 White MERCURY FREE MERCURY FREE Thermostat, Wall Thermostat, Wall Temp range: 50˚F – 90˚F Low Voltage- SPDT 24 Volt- Heating/Cooling System switch: Heat-Off-Cool Fan switch: Auto-On Temp range: 50˚F – 90˚F Low Voltage 24 Volt- Heating/Cooling System switch: Heat-Off-Cool Fan switch: Auto-On Replaces #1F36910 Anticipator Type: Adjustable For use with gas, oil or electric heating/cooling systems Anticipator Type: Adjustable For use with gas, oil or electric heating/cooling systems HC7176 110202 110326 The “Landlordstat” 24V Model: 220RTSP Inlet: 1/2" pipe Outlet: 1/2" inv. flare Shank: 1-3/8", Element: 5-1/2" Model: R110RTS Inlet: 1/2" pipe Outlet: 1/2" inv. flare Shank: 1-1/4", Element: 5-1/2" Thermostat, Wall Thermostat, Gas Water Heater Includes (2) AA batteries for backup Can be preset and not tampered with Thermostat, Gas Water Heater Replaces model #R110RTSP Totally regulated, regulator set at 4.0" W.C. Pilot gas is NOT regulated Regulator set at 3.5" W.C. transformers AT20A1123 AT140A1000 120Volt, 20VA Primary - 120Volt, Secondary - 24Volt, Capacity - 40VA Transformer Transformer MOUNTING OPTIONS: Vertical or horizontal foot mounting or direct mounting MOUNTING OPTIONS: Foot or plate mounting for use on 4"x 4" in., 4" octagon, and 2" x 4" electrical boxes; and clamp mounting via a junction box knockout Designed for any 24V control system (thermostats, gas valves and relays) AT72D1683 90113 Primary - 120Volt Secondary - 24Volt Capacity - 40VA Primary: 120VAC Secondary: 24VAC Ind. Rating @ 250vac: 3/4hp, 12A Res. Rating @ 250vac: 15A Transformer SPDT Fan Control Center (RBM) MOUNTING OPTIONS: Foot mounting; plate mounting for use on 4"x 4" in., 4" octagon, and 2" x 4" electrical boxes; and clamp mounting via a junction box knockout Designed for any 24V control system (thermostats, gas valves and relays) Mounts to 4" junction box Compact transformer & relay provides low voltage control of line voltage for fan motors and auxiliary circuits current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc 199 HVAC heating repair parts Valves 110192 ORDERING NOTES FOR PRESSURE & RELIEF VALVES Valve, Reducing 1/2" #fb-38 Replaces models FB-3 & FB-8 1. Specify pipe inlet & outlet size if uncertain. 2. Specify pressure setting desired, if differnet than shown. Brass body Equipped with fast fill feature Factory set to maintain 12 lbs. system pressure Field adjustable 10-25 psig. 3. In addition to STD settings shown, other settings in 5lb. increments are available within STD range. For additional 10% cost. 374A-3/4-30 174A-3/4-30 Series 374A 3/4" female in and out, factory set at 30 lbs. Relieving capacity is 550,000 BTU/Hr Series 174A 3/4" to 2" female in and out Relieving capacity is up to 14,370,000 BTU/Hr. Valves, Relief A.S.M.E. Water Safety for Hot Water Supply Boilers Valve, Relief A.S.M.E. Water Safety for Hot Water Supply Boilers Iron body with forged bronze inlet Same application as 174A listed below Bronze body Meets Military Spec., MIL-V-136-12D, Type III 100XL-4-150 V8043E1012 Valve, Zone Valve, Relief Temperature & Pressure wfor Water up to 1000,000 24V 3/4" sweat 18" lead wires Series 100 3/4" to 2' female in and out Relieving capacity is up to 14,370,000 BTU/Hr. 802360JA Replacement Motor Valve, Zone 24V 3/4" sweat Terminal board connector Motor can be replaced without breaking line connections or draining the system 5702 5712 1/2" sweat 3/4" sweat Valve, Zone 24V 125 PSIG 65' pump head 2 position zone valve Manual opener with automatic recycle Valve has an actuator motor and valve assembly for controlling flow of hot and/or cold water Includes end switch for sequencing auxiliary equipment Permits accurate temperature control of individual rooms or groups of rooms in residences or commercial buildings 571004RP 1311102 Valve & seat assem. (B) A 555050RP Power unit. (A) Valve, Zone Repair Kit For models 570, 571, 572, 573 200 Motor can be replaced without breaking line connections or draining the system 2 position zone valve Manual opener with automatic recycle Valve has an actuator motor and valve assembly for controlling flow of hot and/or cold water Includes end switch for sequencing auxiliary equipment Bronze body ANSI Z21.22 certified Meets Military Spec., MIL-V-136-12D, Type III V8043F1036 802360JA Replacement Motor B Valve, Hydronic Zone 3 wire 3/4" tubing size 24V valves with push-in wiring panel & auxiliary switch Time cycle: open 45 sec, close 45 sec F190097 Replacement Motor Quiet operating Auxiliary switch contacts control burner or circulator relay current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc valves Valve, Conversion Kit For Modu-Mate Zone Valves 109017 Model # CTS-7524 Valve, Comfort-Trol Zone - 24V 109024 189139 V01340 189137 189138 (1) (2) (3) (4) (5) Operator Bonnet & Retainer Cover Heat Motor ONLY Gland Assem HVAC heating repair parts 109054 3 4 1 Operator is inside of cover 2 Heat motor is inside of operator. 5 Includes Pipe The conversion kit listed above consists of parts 1 thru 5 shown to the right of this box under Comfort-Trol zone valve #109017. Compact, quiet operating 24-Volt Zone Control Valve. Operates at liquid temperature up to 240°F and working pressure up to 125 PSIG. 3/4" sweat connections. 013G8250 013G8252 Operator, RA2000 Operator, RA2000 Zone Valve Zone Valve Valve mounted sensor & dial Valve mounted dial with remote sensor Ideal for baseboard and free-standing radiators where the heating unit is not obstructed by furnishings that interfere with air circulation around the sensor. This operator is always installed horizontally. Ideal for convectors and free-standing radiators where the heating unit is enclosed or obstructed by furnishings. Remote can be installed on a wall where non-restricted air can flow over it. 013G8562 013G8565 013G8252 + 013G8070 Zone Valve 6' capillary Zone Valve 6'5" capillary Operator & Adapter, RA2000 Operator, RA2000 Combined remote mounted dial & sensor Ideal for convectors where thevalve is inaccessible to the user. Remote dial & sensor can be installed on a wall where non-restricted air can flow over it. Replaces old #0137001 013G8252 013G8250 + 013G8072 013G8252 + 013G8072 013G8020 Operator & Adapter, RA2000 Operator & Adapter, RA2000 3/4" Straight x 1-1/4" NPT Zone Valve 013G8072 013G8252 Replaces old #01341100 Zone Valve 013G8252 Replaces old #01341102 013G8072 013G8070 Valve Body, RA2000 For hot water 2 pipe systems Low pressure steam (up to 15 psig) current Pricing can be found on our website All logos, trademarks, part numbers, photos & illustrations are intended solely for identification. Items offered for sale are not represented to be manufactured by the company that built the original equipment. PHONE: 800-843-0903 • FAX: 800-344-1848 • WEB: www.pdqsupplyinc.com • FB: facebook.com/pdqsupplyinc 201