ID, flow indicator for fluid under pressure, flow rate up to 60 l/min.

advertisement
ID, flow indicator
14004US
For fluid under pressure, flow rate up to 60 l/min.
ID_ _C
Applications
Function
These devices have been designed to measure, compare, set and
control (visually or electrically) the flow of any noncorrosive fluid
under pressure.
The flow indicators can be gathered into the control panel of a
circulatingoil lubrication systems, a cooling system, etc.
The flowing fluid moves the float upwards under the effect of a
calibrated pressure loss.
The upward movement of the float is proportional to the fluid
flow rate.
The flow rate can be electrically controlled by means of a sensor
detecting the float. It can be as well visually controlled with the
help on a mark compared to a the scale.
Three different control mode are available: sight and electric
control (type A), sight control (type B), electric control (type C).
Advantages
• A very large range of flow rate from a few liters to several tens
per minute
ID_ _A
ID_ _B
• Good repeatibility of reading
• Measuring any noncorrosive fluid
• Small dimensions
• Very good function reliability
• Very easy to read, whatever the color or the opacity of the
fluid are (for the sight version)
• Possibilty to integrate them to the production lines automatic
control
www.vogelfrance.com
ISO 9001
1995/3256
ID_ _C
14004US
ID, flow indicator
Product range
There are 6 different models of ID flow indicators measuring flow rates from 0 to 60 l/min. It is either possible to detect the float by
means of a sensor (electric control), or to control a mark on the float according to a scale (sight control).
For the sight control (type A et B) there is a mark on the lower part of the float. A scale (percentage) is on the side of the glass and
helps to determine the flow rate according to the level of the mark.
For the electric control (type C), the upper part of the sensor has to be adjsuted in accordance with the size H (see drawing). This
model of indicator suits perfectly to installations where the flow is stable and a visual control not necessary. The flow indicator type
ID_ _ C has been developped for applications, which need at least 6 indicators (in the same operating conditions).
Technical data
Operating range [l/min] .................................................. see table
Operating temperature [°C]....................................... + 10 to + 70
Max. operating pressure [bar] ........................................ see table
Pressure loss [bar] ..................................................................0.5
Inlet coupling ................................................................. see table
Outlet coupling .............................................................. see table
Material .......................................................... brass nickelplated
Sensor (electric control)
. Switch type ILS, snapaction contact,
. Connector M12 x 1, 4 poles
. Operating voltage 24 V to 240 V AC/DC
. Max. power 50 W,
. LED (float detected)
Mouting position .............................................................. vertical
Weight [g] ....................................................................... see table
ID-_ _ C
The size H can be determined and set by our technical department on
the basis of the particular use conditions (viscosity, temperature, flow rate)
according to the information given by the user when ordering.
Order information
Order No
Flow rate (*)
max.
Pressure
max.
Pressure
loss
[L/min]
[bar]
[bar]
visual +
electric
A
Control
visual
electric
B
C
Viscosity
sensitivity
high
low
Inlet
coupling
Outlet
coupling
Weight
[g]
ID01A
1
20
0.5
•
•
G 3/8
G 3/8
641
ID01B
1
20
0.5
•
•
G 3/8
G 3/8
632
ID01C
1
300
0.5
•
•
G 3/8
G 3/8
531
ID02A
2.5
20
0.5
•
•
G 3/8
G 3/8
641
ID02B
2.5
20
0.5
•
•
G 3/8
G 3/8
632
ID02C
2.5
300
0.5
•
•
G 3/8
G 3/8
531
ID03A
3
20
0.5
•
•
G 3/8
G 3/8
641
ID03B
3
20
0.5
•
•
G 3/8
G 3/8
632
ID03C
3
300
0.5
•
•
G 3/8
G 3/8
531
ID07A
7
20
0.5
•
•
G 3/8
G 3/8
641
ID07B
7
20
0.5
•
•
G 3/8
G 3/8
632
ID07C
7
300
0.5
•
•
G 3/8
G 3/8
531
ID30A
30
20
0.5
•
•
G 1/2
G 1/2
641
ID30B
30
20
0.5
•
•
G 1/2
G 1/2
632
ID30C
30
300
0.5
•
•
G 1/2
G 1/2
531
ID60A
60
20
0.5
•
•
G 3/4
G 3/4
641
ID60B
60
20
0.5
•
•
G 3/4
G 3/4
632
ID60C
60
300
0.5
•
•
G 3/4
G 3/4
531
(*) Test condition: oil ISO VG 150 at 40 °C
2
14004US
ID, flow indicator
Dimensions
SIZE
ID01
ID02
ID03
ID07
ID30
ID60
A
B
C
D
E
F
G
H
I
110
G 3/8
35
44
44
40
32
36
40
122
G 3/8
35
44
44
40
32
36
40
122
G 1/2
35
44
44
40
32
36
40
142
G 3/4
46
54
49
50
40
44
44
Accessories to be ordered separately
• Flow limiter valve
Drilling
Valve
Nipple
G 3/8
UH0702.03.210.L1
UH280.03.L
G 1/2
UH1203.04
UH.280.04.L
G 3/4
UH1203.05
UH.280.05.L
• Female connector M 12 and cable for ID types A and C
Order No................................................................... DO.1052.D.05
Cable length ..............................................................................5 m
Service voltage........................................................... 240V AC/DC
Max. current .............................................................................. 1 A
Max. power............................................................................. 50 W
Enclosure................................................................................ IP 66
BN
(1)
BK
(4)
Order No DO.1052.D.05
3
14004US
ID, flow indicator
4
Flow rates
ID 1 :
ID 2 :
Please, consult us.
ID 3 : Test carried out with oil 245 mm2/s at 50°C
Max. pressure loss: 0.4 bar within test condition.
ID 30 :
Test carried out with oil 63 mm2/s at 50°C
Max. pressure loss: 1.2 bar within test condition.
0,2
0,4
[ Height of float ]
[ Height of float ]
0,2
0,45
0,7
0,95
1,2
10
15
20
25
30
1,6
2
75 %
75 %
50 %
50 %
25 %
25 %
0.25 0.5
0.75
1
1.25
1.5
1.75
2
2.25
2.5
2.75
3
3.25
ID 7 : Test carried out with oil 63 mm2/s at 50°C
Max. pressure loss: 0.5 bar within test condition.
5
ID 60 : Test carried out with oil 63 mm2/s at 50°C
Max. pressure loss: 2 bars within test condition.
0,25
1,2
75 %
[ Height of float ]
50 %
25 %
0.5
0,8
0,4
0,5
75 %
[ Height of float ]
Please, consult us.
1
1.5
2
2.5
3
3.5
4
4.5
5
5.5
6
6.5
7
50 %
25 %
10
7.5
15
20
25
30
35
40
45
50
55
60
Notice!
In particular, we call your attention to the fact that hazardous materials of
any kind, especially the materials classified as hazardous by EC Directive
67/548/EEC, Article 2, Par. 2, may only be filled into VOGEL central lubrication systems and components and delivered and/or distributed with the
same after consultation with and written approval from VOGEL.
Dimensions in mm
All products manufactured by VOGEL group are not approved for use in
conjunction with gases, liquefied gases, pressurized gases in solution and
fluids with a vapor pressure exceeding normal atmospheric pressure (1013
mbars) by more than 0.5 bar at their maximum permissible temperature.
Willy Vogel AG
Motzener Strasse 35/37
12277 Berlin, Germany
PF 97 04 44 · 12704 Berlin
Willy Vogel AG
2. Industriestrasse 4
68766 Hockenheim
Germany
Vogel France SAS
Rue Robert Amy, B.P. 70130
49404 Saumur cedex
France
Tel. +49 (0) 30-7 20 02-0
Fax +49 (0) 30-7 20 02-111
info@vogel-berlin.de
www.vogelag.com
Tel. +49 (0) 62 05-27-0
Fax +49 (0) 62 05-27-132
info@vogel-berlin.de
www.vogelag.com
Tel. +33 (0) 241 404 200
Fax +33 (0) 241 404 242
info@vogelfrance.com
www.vogelfrance.com
VOGEL FRANCE SAS - SAS capital 1.283.525 € - RCS Saumur B 353 166 044 - NAF 291F - TVA FR 27 353 166 044
Subject to modification without notice! - 14004US Edition 10/03
All products from VOGEL may be used only for their intended purpose.
If operating instructions are supplied together with the products, the provisions and information therein of specific relevance to the equipment must
be observed as well.
Download