ID, flow indicator 14004US For fluid under pressure, flow rate up to 60 l/min. ID_ _C Applications Function These devices have been designed to measure, compare, set and control (visually or electrically) the flow of any noncorrosive fluid under pressure. The flow indicators can be gathered into the control panel of a circulatingoil lubrication systems, a cooling system, etc. The flowing fluid moves the float upwards under the effect of a calibrated pressure loss. The upward movement of the float is proportional to the fluid flow rate. The flow rate can be electrically controlled by means of a sensor detecting the float. It can be as well visually controlled with the help on a mark compared to a the scale. Three different control mode are available: sight and electric control (type A), sight control (type B), electric control (type C). Advantages • A very large range of flow rate from a few liters to several tens per minute ID_ _A ID_ _B • Good repeatibility of reading • Measuring any noncorrosive fluid • Small dimensions • Very good function reliability • Very easy to read, whatever the color or the opacity of the fluid are (for the sight version) • Possibilty to integrate them to the production lines automatic control www.vogelfrance.com ISO 9001 1995/3256 ID_ _C 14004US ID, flow indicator Product range There are 6 different models of ID flow indicators measuring flow rates from 0 to 60 l/min. It is either possible to detect the float by means of a sensor (electric control), or to control a mark on the float according to a scale (sight control). For the sight control (type A et B) there is a mark on the lower part of the float. A scale (percentage) is on the side of the glass and helps to determine the flow rate according to the level of the mark. For the electric control (type C), the upper part of the sensor has to be adjsuted in accordance with the size H (see drawing). This model of indicator suits perfectly to installations where the flow is stable and a visual control not necessary. The flow indicator type ID_ _ C has been developped for applications, which need at least 6 indicators (in the same operating conditions). Technical data Operating range [l/min] .................................................. see table Operating temperature [°C]....................................... + 10 to + 70 Max. operating pressure [bar] ........................................ see table Pressure loss [bar] ..................................................................0.5 Inlet coupling ................................................................. see table Outlet coupling .............................................................. see table Material .......................................................... brass nickelplated Sensor (electric control) . Switch type ILS, snapaction contact, . Connector M12 x 1, 4 poles . Operating voltage 24 V to 240 V AC/DC . Max. power 50 W, . LED (float detected) Mouting position .............................................................. vertical Weight [g] ....................................................................... see table ID-_ _ C The size H can be determined and set by our technical department on the basis of the particular use conditions (viscosity, temperature, flow rate) according to the information given by the user when ordering. Order information Order No Flow rate (*) max. Pressure max. Pressure loss [L/min] [bar] [bar] visual + electric A Control visual electric B C Viscosity sensitivity high low Inlet coupling Outlet coupling Weight [g] ID01A 1 20 0.5 • • G 3/8 G 3/8 641 ID01B 1 20 0.5 • • G 3/8 G 3/8 632 ID01C 1 300 0.5 • • G 3/8 G 3/8 531 ID02A 2.5 20 0.5 • • G 3/8 G 3/8 641 ID02B 2.5 20 0.5 • • G 3/8 G 3/8 632 ID02C 2.5 300 0.5 • • G 3/8 G 3/8 531 ID03A 3 20 0.5 • • G 3/8 G 3/8 641 ID03B 3 20 0.5 • • G 3/8 G 3/8 632 ID03C 3 300 0.5 • • G 3/8 G 3/8 531 ID07A 7 20 0.5 • • G 3/8 G 3/8 641 ID07B 7 20 0.5 • • G 3/8 G 3/8 632 ID07C 7 300 0.5 • • G 3/8 G 3/8 531 ID30A 30 20 0.5 • • G 1/2 G 1/2 641 ID30B 30 20 0.5 • • G 1/2 G 1/2 632 ID30C 30 300 0.5 • • G 1/2 G 1/2 531 ID60A 60 20 0.5 • • G 3/4 G 3/4 641 ID60B 60 20 0.5 • • G 3/4 G 3/4 632 ID60C 60 300 0.5 • • G 3/4 G 3/4 531 (*) Test condition: oil ISO VG 150 at 40 °C 2 14004US ID, flow indicator Dimensions SIZE ID01 ID02 ID03 ID07 ID30 ID60 A B C D E F G H I 110 G 3/8 35 44 44 40 32 36 40 122 G 3/8 35 44 44 40 32 36 40 122 G 1/2 35 44 44 40 32 36 40 142 G 3/4 46 54 49 50 40 44 44 Accessories to be ordered separately • Flow limiter valve Drilling Valve Nipple G 3/8 UH0702.03.210.L1 UH280.03.L G 1/2 UH1203.04 UH.280.04.L G 3/4 UH1203.05 UH.280.05.L • Female connector M 12 and cable for ID types A and C Order No................................................................... DO.1052.D.05 Cable length ..............................................................................5 m Service voltage........................................................... 240V AC/DC Max. current .............................................................................. 1 A Max. power............................................................................. 50 W Enclosure................................................................................ IP 66 BN (1) BK (4) Order No DO.1052.D.05 3 14004US ID, flow indicator 4 Flow rates ID 1 : ID 2 : Please, consult us. ID 3 : Test carried out with oil 245 mm2/s at 50°C Max. pressure loss: 0.4 bar within test condition. ID 30 : Test carried out with oil 63 mm2/s at 50°C Max. pressure loss: 1.2 bar within test condition. 0,2 0,4 [ Height of float ] [ Height of float ] 0,2 0,45 0,7 0,95 1,2 10 15 20 25 30 1,6 2 75 % 75 % 50 % 50 % 25 % 25 % 0.25 0.5 0.75 1 1.25 1.5 1.75 2 2.25 2.5 2.75 3 3.25 ID 7 : Test carried out with oil 63 mm2/s at 50°C Max. pressure loss: 0.5 bar within test condition. 5 ID 60 : Test carried out with oil 63 mm2/s at 50°C Max. pressure loss: 2 bars within test condition. 0,25 1,2 75 % [ Height of float ] 50 % 25 % 0.5 0,8 0,4 0,5 75 % [ Height of float ] Please, consult us. 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 50 % 25 % 10 7.5 15 20 25 30 35 40 45 50 55 60 Notice! In particular, we call your attention to the fact that hazardous materials of any kind, especially the materials classified as hazardous by EC Directive 67/548/EEC, Article 2, Par. 2, may only be filled into VOGEL central lubrication systems and components and delivered and/or distributed with the same after consultation with and written approval from VOGEL. Dimensions in mm All products manufactured by VOGEL group are not approved for use in conjunction with gases, liquefied gases, pressurized gases in solution and fluids with a vapor pressure exceeding normal atmospheric pressure (1013 mbars) by more than 0.5 bar at their maximum permissible temperature. Willy Vogel AG Motzener Strasse 35/37 12277 Berlin, Germany PF 97 04 44 · 12704 Berlin Willy Vogel AG 2. Industriestrasse 4 68766 Hockenheim Germany Vogel France SAS Rue Robert Amy, B.P. 70130 49404 Saumur cedex France Tel. +49 (0) 30-7 20 02-0 Fax +49 (0) 30-7 20 02-111 info@vogel-berlin.de www.vogelag.com Tel. +49 (0) 62 05-27-0 Fax +49 (0) 62 05-27-132 info@vogel-berlin.de www.vogelag.com Tel. +33 (0) 241 404 200 Fax +33 (0) 241 404 242 info@vogelfrance.com www.vogelfrance.com VOGEL FRANCE SAS - SAS capital 1.283.525 € - RCS Saumur B 353 166 044 - NAF 291F - TVA FR 27 353 166 044 Subject to modification without notice! - 14004US Edition 10/03 All products from VOGEL may be used only for their intended purpose. If operating instructions are supplied together with the products, the provisions and information therein of specific relevance to the equipment must be observed as well.