Hospital Trunking Construction Kit for Medical Ward Units P2148 TECHNICAL INFORMATION 2001:12 P3722 FrontLine Installation System FrontLine is a system for installation of service to modern office workplaces. The system includes products which enable the services to be supplied from the ceiling, the wall or the floor. The system consists of two parts: 1. Service content which includes socket outlets and connections for power, telecommunication and data for access to networks and other services. 2. Service carriers are the cable trunking, servicepoles, floor outlet boxes, service posts and service boxes, with 80 mm front openings (F80®), which make the socket outlets and connections accessible. The F80® front openings ensure that the service content is compatible with the various service carriers. Most FrontLine service carriers can also be delivered pre-wired, with the required service content, ready for connection to service gates in the main network. This will reduce the on-site installation time and make rearrangement of the premises easier. Every pre-wired product is given a serial number and is tested prior to delivery. An individual test re- port is always included. Trademarks The following is a list of Thorsman's and other companies' trademarks, registered and unregistered, used throughout this catalogue. Trademark Company AGA ................................................AGA GAS AB AMP-CO, NetConnect........................AMP Inc Blolite...............................................BICC Brand-Rex Dräger .............................................Dräger Gmbh Ethernet ............................................Digital Equipment Corp./Xerox/Intel Greggersen.......................................Greggersen Gastechnik Gmbh IBM..................................................International Business Machines Corp LUXO ...............................................JAC Jacobsen AS Keystone...........................................Keystone International Holdings PremisNet .........................................Krone(UK)Technique Ltd LexCom ............................................LK as Systimax ...........................................Lucent Technologies Ltd MEDÆS GEM 10 ..............................Meaæs Ltd SUNNEX ..........................................Nolato Sunnex Equipment AB Reichle & De-Massari .........................Reichle & De-Massari Hirschmann.......................................Richard Hirschmann Radiotechnisches Werk CYB, F80, FrontLine, INKA .................Thorsman & Co AB Other brand and product names are the trademark of their respective holders. Approval and Quality Assurance The Thorsman policy is to test and approve products to applicable local and international standards. We operate quality assurance and quality control systems certified according to ISO 9000. Hospital Trunking Construction Kit for Medical Ward Units Medical Ward Unit For All Requirements ........ 4 Straightforward Construction .......................... 6 Many Combinations - Freedom of Choice ........ 8 Complete Access & Outlet Program.................. 10 Design and Dimensions .................................. 12 Medical Ward Unit in Common Ward.............. 13 Medical Ward Unit in Intensive Care .............. 14 Cable Trunking Design .................................. 16 Composition of Lighting Profile ........................ 18 Placement of Light Fitting Rail .......................... 19 Lighting Techniques ........................................ 20 Gas Outlet Installation Techniques .................... 22 Layout Planning ............................................ 24 Colour Choice .............................................. 25 Product Range Service carriers.............................................. 26 Service Content Power ........................................................ 30 Communication .......................................... 38 Lighting ........................................................ 41 Gas.............................................................. 44 Accessory Rail .............................................. 48 Tools ............................................................ 49 Cable Capacity ............................................ 50 Technical Data .............................................. 59 Mounting Details............................................ 60 Specification Guide........................................ 67 Line drawings/photos L31700 For testing and approving we use the following test houses: The number beside line drawings and photos is intended only for ordering digital picture material. NB: When ordering products, use the T-number in the table. Products and technical details are subject to change during the lifetime of the brochure. © THORSMAN & CO AB, 2001. FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 3 Medical Ward Unit in Kit Form for All Requirements 1 2 3 5 4 P2146 1. Lighting unit, full length, colour code L11. 2. Trunking base, type INKA-217-2/90, colour code L11 and L65. 3. Service content, CYB. 4 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 4. Gas profile, full length, colour code L11. 5. Dräger gas outlets. 6. Accessory rail equipped with monitor shelf. Established and Approved Components With a number of established and approved components you can, on-site, construct and install Medical Ward Units adapted to unique nursing situations. The kit allows the construction of a ward unit for the most straightforward form of common ward up to the most complex installations for intensive care spaces. The cable trunking that is one of the main components can also be used to advantage as a carrier of, for example, service content (power, telecommunications, data, etc.) in other work spaces of the hospital or nursing home such as offices or laboratories. The Basis: Cable Trunking, INKA The concept for the kit is built around Thorsman’s cable trunking in aluminium of type INKA. This installation trunking is carrier for all electricity, telecommunications, data and low-voltage current. The size of the trunking is chosen with regard to cable capacity and equipment required. Cable trunking is available in several heights. Some are two-compartment systems, where the lower compartment is screened off by an integral partition. The trunking is available in two depths, 72 mm or 90 mm. A wide range of accessories are available for all INKA cable trunking to ease installation and offer complete solutions. Outlets for Power, Telecommunications and Data Connections 6 A complete range of products for outlets and connections for power, telecommunication, data etc., is available, all mounted easily in the front of the installation trunking. General and Reading/Examining Lighting The kit includes a combined lighting unit for general and reading/examining light. The lighting complies with the German DIN requirements for light dispersion in nursing spaces. The lighting unit can be fitted on the wall close to the INKA cable trunking or separately. Length can be either full-length or adapted to the choice of lighting rail. A bed/examining lamp with arm for mounting on either wall or table is available as an accessory. Gas The assortment of gas outlets include units of Scandinavian, German and English standard for connection to air, oxygen, nitrous oxide, etc. The gas duct can, as with the lighting unit, be mounted on the wall close to the INKA trunking or separately. Gas-pipe cover is available in two designs. Colour Choice All of the visible profile components can be natural anodized or powder coated in a number of standard colours. The colours can be combined in accordance to the wishes of the customer to harmonize with room decor. FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 5 P3826 Straightforward Construction and Installation 6 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Basic Data Description INKA cable trunking, aluminium, 72 and 90 mm deep, with one or two compartments, 80 mm front cover (F80®). Lighting profile with general (indirect), reading/ examining (direct) and optional night light. Choice of light fittings, 80 mm front cover (F80®) Gas outlet profile to suit several gas outlet brands and standards. Gas-pipe cover is available in two designs. • Kit form gives flexibility • Based on Thorsman standard products • Wide assortment • Simple to specify • Easy to install according to clear instructions • Separation of power and low current, lighting and gas • Rapid installation with snap fittings • Labelling of outlets • Easy to clean • Easy to upgrade and add new functions Mounting and installation The hospital trunking components are fixed directly to the wall. The service content is installed in the front opening. The snap-in system makes the installation quick and easy. Detailed mounting instructions are enclosed. Power and Communication The trunking can be equipped with FrontLine Access and Outlet Program type CYB. Delivery lengths Standard length of INKA trunking and front covers, 2.5 m. INKA, lighting and gas pipe front cover available cut to length, max. 5.0 m by special order. Colours Natural anodized or powder coated aluminium1). 1) Can be painted in any shade listed in the NCS and RAL colour ranges, see page 25. FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 7 Many Combinations Give Freedom Of Choice 1 2 3 5 P2150 4 1. Lighting unit, length adjusted to light fitting, see Lighting pages 41-43, anodized. 2. Trunking base, INKA-101/72, see Service carriers, page 26, anodized F80® front with foil M03 red beech 8 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 3. Power and Communication type CYB. 4. Gas profile, with Medaes gas outlets, see page 44, anodized 5. Cover for gas pipe, TRL, see page 46, anodized. A12480 A12490 A12470 Lighting profile in full length and gas pipe cover of TRL type. A12500 Lighting profile and gas pipe cover in full length. Cut-to-length lighting profile and gas pipe cover of TRL type. A10030 Cut-to-length lighting profile and gas pipe cover in full length. Medical Ward Unit installation with lighting profile and gas pipe cover in full length. Accessory rail for attachment of gas and other hospital equipment. FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 9 P4808 Complete Access and Outlet Program Gas outlets for different standards General and Reading/Examining Lighting Our assortment includes outlets corresponding to Scandinavian (AGA), German (Dräger, Greggersen) and British (Medaes) standards. The gas outlets are self-closing and the gas flow cuts off when equipment is disconnected from the quick coupling. The outlets are gas-specific according to the different hospital standards, which means that connection to the wrong outlet is impossible. The selection includes outlets for breathing oxygen, nitrous oxide, breathing air, vaccum, etc. There are lighting rails for different light requirements. 10 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 P4809 FrontLine Hospital Trunking offers a complete selection of every conceivable outlet and connection for electricity, telecommunications, data, gas and lighting. P2154 The ultimate task of a properly designed Medical Ward Unit is to offer the exact function that the nursing situation calls for. The lighting profile can be fitted with various lighting rails for general light (indirect), reading/examining and night light. General light is available in various lengths with standard fluorescent tubes type T26 or new technology tube type T5. Reading/examining light is of standard compact tube type TC. As a supplement to the permanent lighting there are two types of bed/examining lamps by Luxo and Sunnex for table or wall mounting. P2152 Power and Communication, type CYB The power outlet can be delivered colour-coded in white, green or red in order to differentiate normal power from disruption-free or priority power. Call system Mix-up proof labelling P2155 Service content of type CYB contains outlets and connections for power, telecommunications and data networks. The CYB outlet cover plate has a completely smooth surface which facilitates cleaning. Almost any of the existing call systems can be integrated into the Thorsman Medical Ward units. Different types of patient call units are easily mounted into the Thorsman Medical Ward Unit, giving the patient quick access for emergency calls. P3827 Outlets and connections for power, telecommunications and data have distinct labelling panels. Labelling is applied to the mounting frame behind the cover plate. This means that labelling remains even if the cover plate is removed, thus eliminating risk of a mixup when refitting. FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 11 Design and Dimensions B11 B7 B9 B10 B1 B6 B2 B5 B3 A3 B4 B8 A1 A2 C11 C5 C9 C6 S13380 C7 C1 C2 C3 C4 C8 Cable trunking A1 Trunking base, INKA A2 Stop end, trunking base A3 Front cover Lighting B1 Lighting profile B2 Stop end, lighting profile B3 Light fitting rail, TC B4 Compact flourescent tube, TC B5 Prismatic shade B6 Front cover B7 Light fitting rail, T26, T5 (Light tube section) B8 Light fitting rail , T26, T5 (Ballast section) B9 Reflector B10 Flourescent standard tube, T26, T5 B11 Up-light cover Fixing profile, gas outlets Mounting adapter Gas outlet Front cover, gas outlet profile Wall bracket, gas pipe profile Mounting plate with pipe clamps Stop end, front cover Front cover, gas pipe profile Stop end, front cover (gas pipe cover TRL type) Base clamp Gas pipe cover TRL type D14060 Gas C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 12 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 C10 A10050 Medical Ward Unit in Common Ward functions. Suitable for common wards in hospitals, nursing homes and sanatoriums. A10370 A10060 Medical Ward unit with lighting profile only. The unit includes general and reading light and a limited number of electrical A10040 Easy to upgrade with additional electrical and gas functions after installation. A10390 A10380 Medical Ward unit with lighting profile in full length and gas pipe cover of TRL type. Suitable for common wards in hospitals. Medical Ward Unit with lighting profile and gas pipe cover in full length. Accessory rail for attachment of gas and other hospital equipment. INKA cable trunking in two compartments, where the lower compartment is screened off by an integral partition. Suitable for common wards in hospitals. FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 13 Medical Ward Unit in Intensive Care A10400 Wall mounted IC unit Medical Ward Unit with INKA cable trunking in two compartments and gas pipe cover in full length. Possibility for a large number of electrical and gas functions. Double accessory rail system with monitor shelf and examining lamp. A10410 Ceiling mounted IC unit Ceiling mounted Medical Ward Unit for one or several patient beds. The electrical, lighting and gas sections can be double-side equipped.* 14 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 * Ceiling and Floor/Ceiling mounted Intensive Care units are customer specific solutions and are offered on special request A10590 Floor/Ceiling mounted IC unit Floor/ceiling mounted Medical Ward Unit with possibility of maximizing number of electrical and gas functions. The vertical * Ceiling and Floor/Ceiling mounted Intensive Care units are customer specific solutions and are offered on special request as well as the horizontal sections can be double-side equipped.* FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 15 Cable Trunking Design Aluminium cable trunking for wall surface and flush mounting. Cable shelves can be used to divide the trunking into various compartments, so that power and low current cables can be routed in the same trunking as telecommunications and data cables. Several cable trunking products, e.g. INKA-161-2 and INKA-217-2 are two-compartment systems, in which the lower compartment is screened off by an integral partition. Both compartments have separate flush front covers. Earthing slots are provided in trunking base and front cover. For Cable capacity information, see page 50-58. INKA-101/72 and -101/90 R33210M R32430M L38880 For wall surface mounting. INKA-123/72 and -123/90 R33230M R32480M L38890 For wall surface mounting. INKA-123-4/72 R33220 L38900 For flush mounting. INKA-161-2/72 and -161-2/90 16 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 R33250M R32500M L38920 For wall surface mounting. Two screened compartments with separate front covers. INKA-161-3/72 and -161-3/90 R33260M R32780M L47890 For wall surface mounting. INKA-183-2/90 R33280M L47920 For wall surface mounting. Two screened compartments with separate front covers. INKA-217-2/72 and -217-2/90 R33290M R33170M L28370 For wall surface mounting. Two screened compartments with separate front covers. FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 17 Composition of Lighting Profile The Medical Ward Unit offers many possible variations for installation of reading/examining light as well as general light. This makes it possible to obtain the right lighting environment for varying ward requirements. Fitting the lighting profile around the entire room gives maximum space and flexibility for lighting installation. Reading/Examining Light General Light Lighting Profile Dimensions A suitable number of lighting rails can be fitted in the upper compartment of the profile for general (indirect) light. The indirect light can be of standard fluorescent tubes of type T26 (36 or 58W). Alternatively the new technology fluorescent tubes of type T5 (28W or 54W) can be chosen. The lighting rails can either be installed with standard or electronic ballasts. There is also space for a 5W night light in these rails. The lighting profile can be cut to length for a smaller unit and fitted with stop ends for mounting over a bed. Whether the general light is to be provided by standard fluorescent tubes of type T26 or of type T5, the minimum length (L) for cutting the lighting profile can be seen in Figure 1. Lighting rails for reading/examining are installed in the lower compartment over the respective beds. The reading/examining light uses standard compact TC tubes (18 W or 36 W) with either standard or electronic ballasts. The TC 36 W compact tube may also be installed with a dimmable feature for adjustment as a reading or examining light. Figure 1 – Lighting Profile L A10600 L1 L = Length of lighting profile excluding stop ends (2x2mm) General light - Minimum dimensions (mm) Type L Reading/Examining light (mm) Type L1 T26 36W 1400 TC 18W 200 T26 58W 1700 TC 36W 400 T5 28W 1250 TC 36W dimmable (1-10V) 400 T5 54W 1250 18 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Placement of Light Fitting Rail The Light Fitting Rail of type TC (A) is always in one section and is installed in the lower compartment of the lighting profile. The Light Fitting Rail of type T26 or T5 is divided into two sections. The Light Tube section (B) is installed in the upper compartment of the Lighting Profile. The ballast section (C) can be installed in the lower compartment for a short lighting profile section or in the upper compartment for a long lighting profile section. All rails are provided with push-in termination for easy wiring. For selection of Light Fitting Rail, see page 41. A10610 Figure 2 – Placement of Light Fitting Rail into the Lighting Profile Length of Light Fitting Rail (mm) Type A B C TC 18W 550 TC 36W 830 TC 36W dimmable 830 T26 36W 1300 400 T26 58W 1600 400 T5 28W 1230 400 T5 54W 1230 400 T5 Tubes Electronic Ballasts The new T5 fluorescent tubes are characterized by a reduced cross-sectional dimension (16 mm). The more conventional T26 tubes are 26 mm in diameter. More important are the economical advantages of the T5 tubes: • Higher luminous efficiency • Optimized thermal behavior • Longer Lamp service life All fluorescent tubes can be connected to electronic ballasts (35000 Hz). Lighting with electronic ballasts gives an energy saving of about 25% compared to standard ballasts (50Hz). The lamp service life of the fluorescent tube increases by up to 50%. FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 19 Lighting Techniques The values stated below are valid for a 2-bed room. Room dimensions are L=4.5 m, W=4 m, H=2.5 m. General Light General lighting is indirect, creating a comfortable atmosphere by the use of non-dazzling illumination. Fluorescent lamps in either T26 (36 W or 58 W) or T5 (28 W or 54 W) format may be used. Medium intensity of illumination The use of fluorescent lamps conserves energy while providing the required illumination intensity. The warm-white colour of the light helps provide a sense of comfort and well being. DIN 5035 Part 3 2 x T26 36W 2 x T26 58W 2 x T5 28W 2 x T5 54W 100 lx 103 lx 144 lx 103 lx 174 lx Light Dispersion Measuring Levels 1) 2) A10620 A10630 3) 1) Reading level 2) Examining level 3) Bed level. Reading Light The reading light is placed above each bed. The choice is either a TC 18W or 36W compact tube. The statio- nary reading light gives a non-dazzling light without disturbing other patients in the same room. DIN 5035 Part 3 1 x TC 18W* 1 x TC 36W 200 lx 231 lx 354 lx Medium intensity of illumination on the reading surface (75º) * with indirect room light T26 36W Examining light When examining and attending the patient in bed, a certain intensity of illumination is required. These Medium intensity of illumination at bed length axis, 0,85m above floor Minimum intensity of illumination at bed length axis * with indirect room light T26 36/58W 20 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 lighting values are achieved when both the general light and the reading light are turned on. DIN 5035 Part 3 1 x TC 18W * 1 x TC 36W * alt. dimmable* 300 lx 327/392 lx 537/622 lx ≥ 150 lx 155/198 lx 193/253 lx Isolux diagram, 2-bed room Room dimensions: Length 4.5 m x Width 4.0m x Height 2.5 m. Reflexion values: 0.8 Ceiling, 0.5 Wall, 0.3 Floor Measuring height 0.85 m. 50 50 100 150 100 200 250 150 300 200 350 250 300 350 General light Reading/examining light Medium intensity of illumination 2 x T26 2 x TC 246 lx 36W 36W General light Reading/examining light Medium intensity of illumination 2 x T5 2 x TC 347 lx 54W 36W Night light The night light helps the hospital staff to move in the room without switching on the main lighting. The night light can be a 5W bulb fastened on the Light Medium intensity of illumination at bed Fitting Rail. It can also be a light diode unit producing 5 lx at short distance. DIN 5035 Part 3 5W bulb Light diode unit 5 lx ≥ 5 lx ≤ 5 lx FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 21 Gas Outlet Installation Techniques The Thorsman Medical Ward Unit offers the possibility to include gas outlets to Scandinavian, German and British standards. The selection includes outlets for breathing oxygen, nitrous oxide, breathing air, gas exit, vacuum and instrumental air, see page 44. Figure 1 – Positioning of gas outlets The gas outlet is fixed on a wall-mounted fixing profile, the gas outlet cover is snap-fitted on to the fixing profile. The gas outlet cover profile is designed to provide large capacity for gas piping. The cover is prepared for choice of 1,2,3, or 4 gas outlets, see page 45. For more gas outlets a combination of these covers is possible. The positioning of the gas outlets is prepared for c/c measure of 200 mm. This distance is suitable to give appropriate space for a smooth installation and gas pipe connection. 300 150 150 500 150 200 150 700 150 200 200 150 150 200 200 200 150 A10650 A10640 900 The Medical Ward Unit is normally installed as one entire unit. If preferred, the gas outlet profile can be installed separately from the electrical and lighting section. 22 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Gas Outlet Installation Techniques A10660 The gas pipe cover comes in two designs, depending upon how many outlets are required. 200 600 A10670 500 A10680 1. For a limited amount of gas outlets the gas pipe cover can be of TRL type. 200 600 A10690 900 2. For a large number of gas outlets , a full length gas pipe cover is recommended for piping capacity. Gas connection standards Different standards for gas connection are used in various countries. Common to the different standards is the unique adaptation technique in combination with a colour code, preventing connection of the wrong type of equipment to the wrong gas type. The program offers gas outlets according to Scandinavian, German (DIN, two types) and British (BS) standard. The flexible mounting technique also makes it possible to mount gas outlets according to additional standards or local brands. FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 23 Layout Planning The Thorsman Medical Ward Unit (MWU) can to a large extent be adapted to the existing room dimensions. In the layout planning phase there has to be paid attention to certain minimum dimensions when specifying the Medical Ward Unit. The graphics below visualizes a layout of a Medical Ward Unit for up to 3 beds. The length of the Medical Ward Unit is mainly depending on the lighting alternative chosen. The dimensions marked in the graphics are of importance when deciding the total installation. Dimensions: A B Distance from the left end of the MWU until centre of the reading light. Distance between centre of reading lights for two beds. Recommended minimum distance is 1600 mm. Distance from the right end of the MWU until centre of the reading light. Total length of the MWU. Mounting height from floor to top end of the MWU. Recommended distance is 1800 mm. C L H A10710 H The minimum dimensions per 1, 2, 3 beds is depending on the general light chosen, see table below: No of General Light beds *) Reading Minimum dimensions* mm Light A B C L 1 2 3 1 x T26 36W 2x” 3x” TC 18 or 36W ” ” 700 700 700 1600 1600 700 700 700 1400 3000 4600 1 2 3 1 x T26 58W 2x” 3x” ” ” ” 850 850 850 1700 1700 850 850 850 1700 3400 5100 1 2 3 1 x T5 28/54W 2x” 3x” ” ” ” 625 625 625 1600 1600 625 625 625 1250 2850 4450 Dimensions excluding stop ends (2 x 2 mm) 24 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Colour Choice All Thorsman service carriers may be powder coated in any NCS or RAL colour with any gloss value. Below you will find 19 of our stocked colours, in which our products can be powder coated and delivered on short notice. All other RAL or NCS colours are to be offered on special request. When ordering products in a stocked colour, use the three character code which specifies both colour and gloss, eg L01 (=RAL 9010, Semi gloss). Place the code immediately after the article number. P3601 Stocked RAL colours RAL 9010 Code: L01 Semi gloss Code: L02 High gloss, L03 Textured* RAL 7035 Code: L22 High gloss Stocked NCS colours NCS 0402-B91G (≈NCS S 0500-N) NCS S 2502-Y NCS S 6030-R70B RAL 9007 RAL 1013 NCS S 3060-B RAL 1018 RAL 6026 NCS S 0580-Y10R Code: L23 High gloss Code: L61 High gloss Code: L06 High gloss Code: L71 High gloss A selection of non-stocked RAL colours RAL 5024 Code: L31 Semi gloss Code: L11 Semi gloss RAL 1017 Code: L55 Semi gloss Code: L56 Semi gloss Code: L65 Semi gloss A selection of non-stocked NCS colours NCS S 1010-G03Y NCS S 1005-Y80R Non-stocked RAL or NCS colours may be offered on special request. Note: For technical reasons due to the printing process, the colour representations may deviate slightly from the reference colours. There may also be slight differences in shade between batches delivered, even with the same NCS/RAL code. If colour matching with other products is important, please contact Thorsman customer service. FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 25 Service Carriers Trunking bases Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No. 100/72/2500 5504 000 5504 002 123/72/2500 5507 000 5507 002 Trunking base, INKA-101/72 Can be divided into four compartments. With earthing slot. Available cut to length, max 5.0 m by special order. L31700 INKA-U101 Anodized Aluminium Powder coated1) Trunking base, INKA-123/72 Can be divided into four compartments. With earthing slot. Available cut to length, max 5.0 m by special order. L31400 INKA-U123 Anodized Aluminium Powder coated1) Trunking base, INKA-123-4/72 Can be divided into four compartments. With earthing slot. Available cut to length, max 5.0 m by special order. Also suitable as feeder trunking. L32730 INKA-U123-4 Anodized Aluminium Powder coated1) 145/72/2500 5506 310 5506 319 L31450 Trunking base, INKA-161-2/72 Can be divided into five compartments. Includes compartment for telephone communications, data cables, etc. The trunking is pre-punched every 200 mm between the lower and upper compartment. Earthing slot provided. Available cut to length, max 5.0 m by special order. INKA-U161-2 Anodized Aluminium Powder coated1) 161/72/2500 5510 010 5510 012 161/72/2500 5510 020 5510 022 L31300 Trunking base, INKA-161-3/72 Can be divided into four compartments. With earthing slot. Available cut to length, max 5.0 m by special order. INKA-U161-3 Anodized Aluminium Powder coated1) L31250 Trunking base, INKA-217-2/72 Can be divided into eight compartments. Lower compartment for telecommunications, data cables, etc. The trunking is pre-punched every 200 mm between the lower and upper compartment. Earthing slots provided. Available cut to length, max 5.0 m by special order. INKA-U217-2 Anodized Aluminium Powder coated1) 217/72/2500 5514 000 5514 002 100/90/2500 5519 010 5519 012 123/90/2500 5506 400 5506 402 L31020 Trunking base, INKA-101/90 Can be divided into four compartments. With earthing slot. Available cut to length, max 5.0 m by special order. INKA-U101 Anodized Aluminium Powder coated1) L31090 Trunking base, INKA-123/90 Can be divided into four compartments. Earthing slot provided. Available cut to length, max 5.0 m by special order. 1) INKA-U123 Anodized Aluminium Powder coated1) Colour choice, see page 25. 26 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Service carriers Trunking bases (cont.) Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No. L31170 Trunking base, INKA-161-2/90 Can be divided into five compartments. Includes compartment for telecommunications, data cables, etc. The trunking is pre-punched every 200 mm between the lower and upper compartment. Earthing slots provided. Available cut to length, max 5.0 m by special order. INKA-U161-2 Anodized Aluminium Powder coated1) 161/90/2500 5519 020 5519 022 161/90/2500 5512 230 5512 232 Trunking base, INKA-161-3/90 Can be divided into four compartments. With earthing slot. Available cut to length, max 5.0 m by special order. L32790 INKA-U161-3 Anodized Aluminium Powder coated1) Trunking base, INKA-183-2/90 Can be divided into six compartments. Includes compartment for telecommunications, data cables, etc. The trunking is pre-punched every 200 mm between the lower and upper compartment. Earthing slots provided. Available cut to length, max 5.0 m by special order. L31240 INKA-U183-2 Anodized Aluminium Powder coated1) 183/90/2500 5519 060 5519 062 Trunking base, INKA-217-2/90 Can be divided into eight compartments. Includes compartment for telecommunications, data cables, etc. The trunking is pre-punched every 200 mm between the lower and upper compartment. Earthing slots provided. Available cut to length, max 5.0 m by special order. Anodized Aluminium Powder coated1) 217/90/2500 5519 040 5519 042 Type/ Description Colour/ Finish Dimensions A/B/C (mm) Art. No. L44190 INKA-U217-2 Front covers Materal Front cover FCA-F40, F80. Snap-fit fastening onto trunking. With earthing slots. Anodized Aluminium Powder coated1) 40/2500 5580 030 5580 039 FCA-F80 Anodized Aluminium Powder coated1) 80/2500 5580 080 5580 089 L30840 L30830 FCA-F40 1) Colour choice, see page 25. FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 27 Service carriers Stop ends Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No. L32410 L32570 L46040 Stop end Stop ends including screws for fixing and angle brackets (for 72 mm deep trunking only). The angle brackets are inserted in the jointing piece rails (for INKA-101 also into the earthing rail). Stop ends are used to terminate cable trunking and to limit electric fields. INKA-ES101/72 Powder coated1) Aluminium/Steel2) 100/72/51 5504 172 INKA-ES123/72 Powder coated1) Aluminium/Steel2) 123/72/36 5507 172 INKA-ES161/72 Powder coated1) Aluminium/Steel2) 161/72/36 5510 172 INKA-ES217/72 Powder coated1) Aluminium/Steel2) 217/72/36 5514 172 INKA-ES101/90 Powder coated1) Aluminium 100/90 5590 217 INKA-ES123/90 Powder coated1) Aluminium 123/90 5591 152 INKA-ES161-2/90 Powder coated1) Aluminium 161/90 5590 277 INKA-ES161-3/90 Powder coated1) Aluminium 161/90 5591 062 INKA-ES183-2/90 Powder coated1) Aluminium 183/90 5591 032 INKA-ES217-2/90 Powder coated1) Aluminium 217/90 5590 307 Stop end INKA-ESV123-4/72 Left Powder coated1) Aluminium 5590 203 Powder coated1) Aluminium 5590 208 Colour/ Finish Material INKA-ESH123-4/72 Right Trunking Accessories Type/ Description Dimensions A/B/C (mm) Art. No. Cable shelf Used to divide the trunking into a maximum of eight compartments. Cable shelves are used for improved segregation and screening between power, low current, telephone and data cables. L32020 KH72 for 72 mm deep and KH90 for 90. TTI-KH72 TTI-KH72 TTI-KH90 TTI-KH90 Anodized Unspecified Untreated White Aluminium PVC Aluminium PVC 12/72/500 12/72/500 12/90/500 12/90/500 5590 5590 5590 5590 312 314 315 316 L32010 Cable clip Snap-fitted on cable shelf. Prevents cables falling out of trunking compartment before front cover is installed. TTI-KHK Brown ABS - 5590 340 L53540 Mounting washer Used when mounting the trunking directly on the wall. The carrier is hung on a number of mounting washers before being secured to the wall with screws. TTI-MB Black PA 16/6/19 1) Colour choice, see page 25. 2) If trunking base in anodized finish is being used, powder coated stop end in ’RAL 9007’ is recommended. 28 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 5590 180 Service carriers Trunking Accessories (cont.) Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No. Untreated Aluminium 8/32/60 5590 112 Jointing piece For jointing trunking. L44850 INKA-SSA Earthing clamp For bonding the front cover, trunking base and accessories to earth. Zinc passivated Steel – 5590 500 L34520 TTI-JB Earth wire For bonding the front cover, trunking base and accessories to earth. Green/Yellow Copper Length = 300 mm 5590 505 L51170 TTI-JK300 L32140 Sound insulation strip For sound insulation of up to 53 dB where trunking passes through walls. Suitable for up to four compartments. Supplied in sets of four. TTI-T3045 TTI-T5070 Black Foam rubber 30/350/45 50/350/70 5590 410 5590 414 Ø 13 5590 520 Cup washer For covering screw heads and protecting the cable. Black PE L33370 TTI-KB L33380 Grommet To cover edges where cables passes between trunking base and lighting profile. Provides a hole of Ø 19 mm for cable entry. (Use plunge tool ISV-HS, see page 43). INKA-GF19 White PP Ø 20 5902 100 Edge protection To protect cables from sharp edges when a small gap is left between two aluminium trunking bases. Transparent PE – 5902 120 – 5586 600 L33390 INKA-KD82 L12600 Locking plate To fix various equipment directly to the trunking. TTI-GM Grey PA L33090 Washer For insertion between cable trunking/lighting profile/gas profile and wall to compensate for uneveness in the wall. TTA-KM1 TTA-KM3 TTA-KM5 Grey PA 114/1/38 114/3/38 114/5/38 5583 405 5583 408 5583 410 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 29 Power 1. Angled corners for simple cable entry with two adjoining boxes 2 1 2. Snap-fitting to F80™ front opening. Fits all FrontLine service carriers. 3 3. Strain relief clamps without screws 4 4. Large label window, 66 x 10 mm, for fixed mounting in the box 5 5. Opening for label window 6. Bridging terminal 4 x 2.5 mm2. Push-in. 6 7. Outlet recesses angled at 37° 8. Child protection 7 P2158 8 Colours White = NCS 0701-G46Y ≈ RAL 9016 Red = RAL 3003 ≈ NCS 3163-Y97R Green = RAL 6029 ≈ NCS 3658-G03Y Connection kits, Schuko Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No. With child protection CYB-PS White PC/ABS 84/52/84 5975 000 With child protection and LED indication, green CYB-PS White PC/ABS 84/52/84 5975 005 L58920 L57350 Connection kit Single earthed socket outlets, Schuko 90° Includes box, adapter, 2x strain relief clamps, cover, label and label window. The socket has push-in terminals. Connection kit Double earthed socket outlets, Schuko 37° Includes box, adapter, 2x strain relief clamps and cover. The socket has push-in terminals. With label and label window. (The different colours may be used for special outlet designation e.g., priority power) L46510 With child protection CYB-PS White Red Green Orange PC/ABS 84/46/110 5951 5951 5951 5951 480 482 485 487 Connection kit Three-gang earthed socket outlets, Schuko 37° Includes box, adapter, 2x strain relief clamps and cover. The socket has push-in terminals. With label and label window. (The different colours may be used for special outlet designation e.g., priority power) L46520 With child protection CYB-PS White Red Green Orange 30 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 PC/ABS 84/46/142 5951 5951 5951 5951 430 432 435 437 Power Connection kits, Double socket, French Standard Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No. French Standard, for Poland and France (with Push-in terminals) CYB-outlet. Two-gang, 16A/250V. Includes double earthed socket, box, strain relief clamps and spacer. CYB-PF CYB-PF White Red PC/ABS 84/45/110 84/45/110 5969 215 5969 217 L57830 French Standard, for Belgium, Poland and France (with screw terminals) CYB-outlet. Two-gang, 16A/250V. Includes double earthed socket, box, strain relief clamps and spacer. CYB-PF CYB-PF White Red PC/ABS 84/45/110 84/45/110 5969 210 5969 212 French Standard, for Czech Rep., Poland and France (with Push-in terminals) CYB-outlet. Two-gang, 16A/250V. Includes double earthed socket, box, strain relief clamps and spacer. CYB-PF CYB-PF White Red PC/ABS 84/45/110 84/45/110 5969 115 5969 117 L57820 French Standard, for Czech Rep., Poland and France (with screw terminals) CYB-outlet. Two-gang, 16A/250V. Includes double earthed socket, box, strain relief clamps and spacer. CYB-PF CYB-PF White Red PC/ABS 84/45/110 84/45/110 5969 110 5969 112 Colour/ Finish Material Dimensions A/B/C (mm) Art. No. Connection kits, British Standard Connection kit, Power, single, 13 A Snap-fastened 13 A single standard outlet, consisting of CYB-S40 box, outlet, adapter and front plate. The outlet can be mounted either horizontally or vertically. Used as single outlet, in conjunction with CYB outlets for power, telecommunication, data and blank covers. CYB-PU, unswitched White PC/ABS 84/47/84 5961 130 CYB-PU, switched White PC/ABS 84/50/84 5961 120 CYB-PU, switched with indicator White PC/ABS 84/50/84 5961 140 L44520 L44510 L44500 Type/ Description L44550 L44540 L44530 Connection kit, power, twin, 13 A Snap-fastened 13 A double standard outlet, consisting of box CYB-D40, outlet, adapter and front plate. Used as double outlet, in conjunction with CYB outlets for power, telecoms, data and blank covers. CYB-PU, unswitched White PC/ABS 84/47/142 5961 135 CYB-PU, switched White PC/ABS 84/50/142 5961 125 CYB-PU, switched with indicator White PC/ABS 84/50/142 5961 145 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 31 Power Basic kit, CEE socket outlets Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No. L28200 L28190 CEE socket outlets Power socket outlets including mounting frame for 80 mm front (F80®) opening. To be used in conjunction with Thorsman MIB-box. Single-phase CEE216-6, 250 V/16 A for cable 3x1.5 mm2 CYB-C220 Grey/blue PC 82/49/82 5960 110 Three-phase CEE416-6, 440 V/16 A, for cable 5x2.5 mm2 CYB-C380 Grey/red PC 82/57/82 5960 100 Connection kit, Surge protection Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No. L53510 Connection kit with overvoltage protection 16 A/230 V, TN system CYB-PP connection kit with overvoltage protection is suitable for 230 VAC and TN system. The protection is intended for individual workplaces and not for entire buildings or installations. The protection has a built-in acoustic alarm and external indications for operation and overloading. The acoustic alarm is controlled with the aid of a switch mounted in the front. The protection can also be monitored by a circuit-opening contact for connection to a monitoring centre, for example. CYB-PP White PC/ABS 84/53/84 5972 010 Connection kit, Switches Type Description Closed position Colour/ Finish Material Dimensions A/B/C (mm) Art. No. Connection kit, Switches, 16A/250V Includes box, socket, adapter, two strain relief clamps, cover with rocker, label with label window. L57370 Single-pole CYB-PB Up White PC/ABS 84/54/84 5980 002 Single-pole, spring-return rocker CYB-PB Up White PC/ABS 84/54/84 5980 007 Single-pole, red indicator lamp CYB-PB Up White PC/ABS 84/54/84 5980 012 Single-pole, green indicator lamp CYB-PB Up White PC/ABS 84/54/84 5980 017 Double-pole CYB-PB White PC/ABS 84/54/84 5980 032 Single-pole/two-way CYB-PB Up White PC/ABS 84/54/84 5980 052 Intermediate CYB-PB White PC/ABS 84/54/84 5980 062 Up Up 32 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Power Connection kits, Switches (cont.) Type Description Closed position Colour/ Finish Material Dimensions A/B/C (mm) Art. No. Connection kit, switches, 16 A/250 V Includes box, socket, adapter, two strain relief clamps, cover with two rockers and label with label window. L57360 Two-gang CYB-PB Up White PC/ABS 84/54/84 5980 072 Venetian blind CYB-PB Up White PC/ABS 84/54/84 5980 087 Venetian blind, single-pole switch CYB-PB Up White PC/ABS 84/54/84 5980 082 Double single-pole/two-way CYB-PB Up PC/ABS 84/54/84 5980 057 16/25/39 5972 105 White L57480 Pilot lamp 0.9 mA 250 V Intended to be mounted together with switch. CYB-GL2 L58940 Push-in plint For single socket outlets, switches and dimmers. 16A/250V, 3x2,5 mm2. CYB-PT White 10/10/14 5972 200 Double single-pole/ two-way (6/2) D13950 Double-pole (2) D13940 D13970 D13910 Intermediate (7) Two-gang (5) Venetian blind single-pole D13990 D13960 Single-pole/two-way (6) Single-pole with indication (1) D13980 Single-pole with spring-return (1) Single-pole (1) D13900 D13920 D13930 Wiring diagrams for switches Venetian blind FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 33 Power Connection kit Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No. L59000 Light Diode Kit The light diode kit consists of 8 pcs. high intensity diode in a CYB mounting frame with protective casing. For night light in common ward. Available autumn 1999. CYB-PO angled White PC/ABS 84/50/84 Material Dimensions A/B/C (mm) 5974 010 Connection kit, Dimmers 230V, F80 Mounting Type/ Description Colour/ Finish Art. No. L57840 Dimmers To control fluorescent light fittings with controllable HF units. 1-50 HF units can be controlled. The positive and negative poles of the controller must be connected to the positive and negative poles of the HF unit. Poles 1 and 2 of the switches are wired to switch the fittings on and off. The break function is rated at max 6 A (max 360 W fluorescent tube rating). If the load is higher, the break function can control a relay coil instead. Note that the fluorescent tubes must not go out at the minimum setting of the controller. Rating 1-10 V for 1-50 HF units made by Philips, Osram, Siemens, Helvar, etc. To be connected to the plus and minus connections of the controller. Note that it is very important to observe correct polarity throughout the installation. Controller 1-10 V (APE 10 T). CYB-PR White PC/ABS 84/53/84 5985 020 For incandescent lamps and electronic transformers, 300W (ATD 300R). CYB-PR White PC/ABS 84/53/84 5985 000 For incandescent lamps and conventional transformers, 400W, VA (AD 400UTT). CYB-PR White PC/ABS 84/53/84 5985 030 For incandescent lamps, fluorescent lamps with dimmable electronic ballast and conventional transformers, 900W, VA (ATTD 1000RL). CYB-PR White PC/ABS 84/53/84 5985 050 Dimensions A/B/C (mm) Art. No. Mounting boxes and blank covers Type/ Description Colour/ Finish Material L44350 L44360 Mounting box For the installation of power and low-current equipment in FrontLine service carriers with 80 mm front (F80™). When fitted with screw pillars CYB-P40, the box is also suitable for standard socket outlets with centres to BS 4662:1970 and with screw pillars CYB-P3 for 60 mm centres. Single box with ten 16 mm knockouts CYB-S40 White PC Double box with fourteen 16 mm knockouts CYB-D40 White PC 79/44/84 5961 030 79/44/142 5961 035 Blanking cover, single CYB-PL White PC/ABS 84/12/84 5961 550 Blanking cover, double CYB-PL White PC/ABS 84/12/142 5961 555 L44370 L44380 Blanking cover Blanking cover for snap fitting. Includes adapter and front plate. Fits CYB-S30 and CYB-S40. To blank off mounting boxes for future expansion of electrical installations. 34 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Power Accessories for Mounting boxes and Mounting kits Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No. L44390 Screw pillars Screw pillars which snap-fit to CYB-D40 and CYB-S40 boxes, so that standard socket outlets can be fitted. CYB-P40 to British standard, and CYB-P3 for 60 mm centres. CYB-P40 CYB-P3 White PA 14/12/37 10/11/42 5961 505 5961 506 L16310 Adapter, for flexible conduit For snap-fitting flexible conduit as a protective cable conduit. CYB-D20 is used for 20 mm, CYBD25 for 25 mm flexible conduit. CYB-D20 CYB-D25 Black PA,PP Ø 26/24 Ø 29/26 5956 250 5956 255 L46080 Earthing terminal Used in CYB-S30/D30 and S40/D40 mounting boxes. The earthing terminal can take 2x4 mm2 cable. CYB-ET Natural Brass – 5961 500 L45400 Conduit bush For use between CYB mounting boxes, mounted directly beside each other for protection of cables. CYB-CT PC/ABS 5961 510 L34510 Strain relief Used when connecting power cable to box. Snap-fits in the recess of the CYB box. FDS Orange 25/27/17 5956 150 Installation boxes Single and double installation box intended for mounting of standard devices in front F80® service carriers, MIB-A1 for devices with a c/c distance of 60 mm and MIB-A2 for a c/c distance of 71 mm. Can be combined with junction box MIB-J. White PC/ABS 79/45/71 5586 150 MIB-A2 White PC/ABS 79/45/152 5586 155 L59810 L59800 MIB-A1 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 35 Power Mounting kit for accessories (other suppliers) Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No. CYB-MB White PC/ABS 84/50/84 5971 790 CYB-MB White PC/ABS 84/50/84 5971 794 Dimensions A/B/C (mm) Art. No. L46940 L13300 Mounting kit for other types of socket outlets Includes mounting box and universal adapter for socket outlets according to DIN 49075. Equipotential connection Type/ Description Colour/ Finish Material Equipotential connection Equipotential connection in front cover F80®. For potential balancing, max. 63A or according to DIN standard. Pole marking yellow/green. Anodized Powder coated1) Aluminium 80/-/110 5971 302 5971 301 CYB-PO, DIN Anodized Powder coated1) Aluminium 80/-/110 5971 307 5971 306 L50820 L50540 CYB-PO, (max 63 A) Equipotential connection kit Equipotential connection kit for snap-in mounting in service carriers with front cover F80®. For potential balancing according to DIN standard 42801. White PC/ABS 84/28/84 5971 315 L64230 CYB-PO, DIN Plug for equipotential connection. DIN type L64280 CTA-PO 1) Colour choice, see page 25. 36 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 5914 050 Power DIN enclosures Type/ Description Material Colour Dimensions A/B/C (mm) Art. No. L61530 DIN enclosure 4-module DIN enclosure intended for snap-in mounting in service carriers with front F80®. The enclosure is suitable for 1-4 DIN modules and has a hinged lid to protect the devices. CYB-PN PC/ABS White 84/86/168 5960 251 White 84/86/168 5960 256 Colour A/B/C (mm) Dimensions Art. No. L61540 Same as above but with keylock and keys to lock the lid. CYB-PN PC/ABS Circuit breakers Type/ Description Circuit breakers Miniature circuit breakers (MCB) 6 kA according to DIN VDE 0641, Part 11/08.92 and EN 60 898, B- and C- characteristics. Rated current 10 A and 16 A. 1, 2, 3-poles (1-2-3 DIN modules). To be mounted in CYB-PN DIN-enclosure. Material: ABS. L46870 CYB-PN, CYB-PN, CYB-PN, CYB-PN, CYB-PN, CYB-PN, CYB-PN, CYB-PN, CYB-PN, CYB-PN, 1-pole, 1-pole, 2-pole, 2-pole, 2-pole, 2-pole, 3-pole, 3-pole, 3-pole, 3-pole, C10A C16A B10A C10A B16A C16A B10A C10A B16A C16A Grey 90/74,5/18 Grey 90/74,5/36 Grey 90/74,5/54 5960 5960 5960 5060 5960 5960 5960 5960 5960 5960 480 485 460 490 465 495 470 500 475 505 Earth leakage breaker Residual-current circuit breakers for pulsating direct and altering earth-leakage current according to DIN VDE 0644, Part 1/10.85. Resistance to surge current up to 250 A. Rated current 25 A. Rated residual current 0,03 A.2 and 4 poles (2 and 4 DIN modules). To be mounted in CYB-PN DINenclosure. Material: ABS. Colour: Grey. CYB-PN, 2-pole CYB-PN, 4-pole Grey Grey 84/74/36 84/74/72 5960 415 5960 410 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 37 Communication 9 1 3 2 4 1. 2 3. 4. 5. 6. 6 7. 5 8. 9. P2159 7 8 Extra distinct label 66x10 mm Label window to protect label (snap-fits into mounting frame) Connectors Snap-fitting cover Mounting frame for F80®. Suitable for horizontal or vertical snap-fitting. Mounting frame which allows a full visual check of the completed installation Modular mounting plate for angled or flush snap-fitting. With facility for extra marking 21x4.7 mm Silk-matt glare-free easy-clean surface Protective cover for data connectors. Additional. Colours White = NCS 0701-G46Y ≈ RAL 9016 Connection kits, Data Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No. L55310 L55300 Connection kit, LexCom 250, 125 UTP and STP For mounting in FrontLine service carriers with 80 mm front (F80®). Includes cover, mounting frame, mounting plate, label with label window, connector and termination instructions. 1 2 1 2 1 2 1 2 x x x x x x x x Cat6 UTP, A/B Cat6 UTP, A/B Cat6 STP, A/B Cat6 STP, A/B Cat5e UTP, A/B Cat5e UTP, A/B Cat5e STP, A/B Cat5e STP, A/B White PC/ABS 84/50/84 White PC/ABS 84/30/84 5974 5974 5974 5974 5970 5970 5970 5970 090 095 100 105 900 905 910 915 L55220 Connection kit, Avaya (Lucent) MPS300, 100 UTP For mounting in FrontLine service carriers with 80 mm front (F80®). Includes cover, mounting frame, mounting plate, label with label window, connector and termination instructions. With built-in shutters. 1 2 1 2 1 2 1 2 x x x x x x x x Cat6 UTP, A Cat6 UTP, A Cat6 UTP, B Cat6 UTP, B Cat5e UTP, A Cat5e UTP, A Cat5e UTP, B Cat5e UTP, B White PC/ABS 84/33/84 White PC/ABS 84/33/84 5970 5970 5970 5970 5970 5970 5970 5970 960 965 870 975 800 805 810 815 L55220 Connection kit, AMP110, Netconnect UTP and STP For mounting in FrontLine service carriers with 80 mm front (F80®). Includes cover, mounting frame, mounting plate, label with label window, connector and termination instructions. With built-in shutters. 1 2 1 2 1 2 1 2 x x x x x x x x Cat6 UTP A/B Cat6 UTP A/B Cat5e UTP A/B Cat5e UTP A/B Cat5e STP A Cat5e STP A Cat5e STP B Cat5e STP B White PC/ABS 84/33/84 White PC/ABS 84/33/84 5970 5970 5970 5970 5970 5970 5970 5970 930 935 840 845 850 860 855 865 L55300 Connection kit, IBM ACS type C, UTP and FTP For mounting in FrontLine service carriers with 80 mm front (F80®). Includes cover, mounting frame, mounting plate, label with label window, connector and termination instructions. 1x 2x 1x 2x Cat5, Cat5, Cat5, Cat5, UTP UTP FTP FTP White 38 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 PC/ABS 84/50/84 5970 5970 5970 5970 355 360 365 370 Communication Connection kits, Data (cont.) Type/ Description Colour Material Dimensions A/B/C (mm) Art. No L55270 Connection kit, IBM type 1, STP for structured cable systems For mounting in FrontLine service carriers with 80 mm front (F80®). Includes cover, mounting frame, mounting plate, label with label window, connector and termination instructions. 1 x IBM type 1, STP White PC/ABS 84/50/84 5970 345 L55360 Connection kit, IBM type 2, STP for structured cable systems For mounting in FrontLine service carriers with 80 mm front (F80®). Includes cover, mounting frame, mounting plate, label with label window, connector and termination instructions. 1x IBM type 2, STP and 1 x 8-way modular socket White PC/ABS 84/50/84 5970 350 L55220 Connection kit, Krone Keystone for PremisNET structured cable systems For mounting in FrontLine service carriers with 80 mm front (F80®). Includes cover, mounting frame, mounting plate with built-in dust shutter, label with label window, connector and termination instructions. With built-in dust shutters. 1 2 1 2 x x x x Cat5e Cat5e Cat5e Cat5e UTP, B UTP, B STP, B STP, B White PC/ABS 84/33/84 5970 5970 5970 5970 760 765 770 775 Material Dimensions A/B/C (mm) Art. No Connection kits, fibre optics Type/ Description Colour L55250 Connection kit, LexCom fibre, multimode for fibre-based cable systems For mounting in FrontLine service carriers with 80 mm front (F80®). Includes cover, mounting frame, mounting plate, SC/SC adapter, label with label window, and termination instructions. 1 x SC-duplex, multimode 2 x SC-duplex, multimode White PC/ABS 84/50/84 5974 000 5974 005 L55260 Connection kit, AMP SC and Avaya (Lucent) ST, multimode for fibre-based cable systems For mounting in FrontLine service carriers with 80 mm front (F80®). Includes cover, mounting frame, mounting plate, label with label window, connector and termination instructions. 2x ST, Multimode 1 x SC-duplex, multimode 2 x SC-duplex, multimode White PC/ABS 84/50/84 5970 375 5970 380 5970 385 L55260 Protective casing for fibre optics For mounting in FrontLine service carriers together with two CYB-BK sockets. Suitable for horizontal or vertical mounting, since outlets can be rotated in the casing. Copper and fibre cables can be connected to the casing. In the short side there is a breakout notch for a cable nipple type BICC Brand-Rex Blolite system. CYB-DF White PP 79/39/168 5971 220 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 39 Communication Connection kits, Telephone Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No Connection kits, modular socket Cat 5e For mounting in FrontLine service carriers with 80 mm front (F80®). Includes cover, mounting frame, mounting plate, label with label window, connector and termination instructions. L55310 1x RJ45 2x RJ45 White PC/ABS 84/26/84 84/26/84 5970 520 5970 525 Connection kits, modular socket For mounting in FrontLine service carriers with 80 mm front (F80®). Includes cover, mounting frame, mounting plate, label with label window, connector and termination instructions. 1x RJ11 2x RJ11 White PC/ABS 84/26/84 84/26/84 5970 510 5970 515 Connection kits, Low current and Coaxial cable networks, Aerial, Radio/TV Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No L28250 L50890 Connection kit, radio/TV aerial For mounting in FrontLine service carriers with 80 mm front (F80®). Includes cover, mounting box CYB-S40 and connectors with centre plate. 1 x radio/TV White PC/ABS 84/51/84 CAN-A75, termination resistor 5970 595 5954 120 L55290 Connection kit, D-connectors For mounting in FrontLine service carriers with 80 mm front (F80®). Includes cover, mounting frame, mounting plate, label with label window, connector and termination instructions. 1 x D-sub 9-pole 1 x D-sub 15-pole 1 x D-sub 25-pole White PC/ABS 84/50/84 5970 310 5970 315 5970 320 Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No Accessories Protective Casing For data connectors and cable connections. To be mounted on the back of the mounting frame. Red Red L55300 CYB-RK, high CYB-RK, low 40 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 PP 63/38/63 63/26/63 5971 200 5971 205 Lighting Lighting profile, Light fitting rail, Covers, Stop ends Type/ Colour/ Dimensions Description Finish A/B/C (mm) Art. No. L50700 Lighting profile Provides general light, reading/examining light and night light. To be equipped with Thorsman light fitting rails in combinations of your own choice. Two separate compartments. With earthing slot. F80® front cover and CYB outlets will snap fit into the 80 mm front (F80®) opening of the profile. Available cut to length, max 5.0 m by special order. For cutting of profile in correct length to suit chosen light fitting rail, see Figure 1 page 18. Material: Aluminium. MWU-LP Anodized Powder coated1) Anodized Powder coated1) 72/180/2500 6200 6200 72/180/1250 6200 6200 002 001 006 005 Light fitting rail To be fixed into the lighting profile. Provides for general light, reading/examining light and night light. Complete with standard or electronic ballasts and reflectors, ready to use. All wiring on the rail is provided for. Push-in termination. Prepared for earthing. Screw fixed, supplied with screws. The rails type T26 and T5 are two-section rails to be installed in separate compartments in the lighting profile, see Figure 2 page 19. Fluorescent tubes to be ordered separately. Material: Zinc coated steel. L57550 MWU-LR, MWU-LR, MWU-LR, MWU-LR, MWU-LR, Type Type Type Type Type TC TC TC TC TC 18W, 18W, 36W, 36W, 36W, fluorescent compact fluorescent compact fluorescent compact fluorescent compact fluorescent compact dimmable (1-10V) tube, tube, tube, tube, tube, standard ballasts electronic ballasts standard ballasts electronic ballasts electronic ballasts 40/77/550 40/77/550 40/77/830 40/77/830 6200 6200 6200 6200 40/77/830 6200 212 MWU-LR, Type T26 36W,fluorescent standard tube, standard ballasts L50500 L50870 L57570 40/77/1300+ 40/77/400 MWU-LR, Type T26 36W,fluorescent standard tube, electronic ballasts ” MWU-LR, Type T26 58W,fluorescent standard tube, standard ballasts 40/77/1600+ 40/77/400 MWU-LR, Type T26 58W,fluorescent standard tube, electronic ballasts ” 150 151 210 211 6200 205 6200 206 6200 200 6200 201 MWU-LR, Type T5 28W, fluorescent standard tube, electronic ballasts 40/77/1230+ 40/77/400 MWU-LR, Type T5 54W, fluorescent standard tube, electronic ballasts ” 6200 160 6200 165 T26, fluorescent std. Tube 36W T26, fluorescent std. Tube 58W T5, fluorescent std. Tube 28W T5, fluorescent std. Tube 54W TC, fluorescent compact Tube 18W TC, fluorescent compact Tube 36W 6200 6200 6200 6200 6200 6200 L=1200 L=1500 L=1149 L=1149 L=217 L=410 225 230 245 250 240 220 L64330 Pull-cord switch Pull-cord switch, 1-pole 2A 250V, to be mounted on light fitting rail of type TC, 18W and 36W. Length of cord = 100 cm. Suitable for: MWU-LR Type TC. MWU-LS 30/11,5/22 6200 301 L50490 L57540 Night Light Lamp holder for night light. Suitable for lamp bulbs with E14 socket. To be fixed on the light tube section of the general rails type T26 or T5 (fixation prepared). Lamp to be ordered separately. MWU-LA 6200 291 IBP/F 5 W bulb (dim) 6200 605 L59000 Light Diode Kit The light diode kit consists of 8 pcs. high intensity diodes in a CYB mounting frame with protective casing. For night light in common ward. Available autumn 1999. Material: PC/ABS 1) CYB-PO angled Colour choice, see page 25. White 84/50/84 5974 010 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 41 Lighting Lighting profile, Light fitting rail, Covers, Stop ends, cont. Type/ Colour/ Description Finish Material Dimensions Art. No. A/B/C (mm) L50710 Up-light cover To cover upper part of lighting profile. To be positioned in track of the profile. Material: PMMA MWU-LC Transparent 3/100/2500 6200 805 80/2500 5580 080 5580 089 Front cover Snap-fit fastening onto lighting profile. With earthing slots. L30840 FCA-F80 Anodized Powder coated1) Aluminium L50780 Prismatic shade Transparent front cover with a linear prismatic back-side to direct the light. Snap-fit fastening onto lighting profile. MWU-LF Transparent (TC 36W) PMMA Transparent (TC 18W) 80/400 80/200 6200 800 6200 801 72/180/2 6200 051 6200 056 L50670 Stop end, lighting profile The stop end is fixed with screws. Supplied with screws 2). 1) MWU-LE, left MWU-LE, right Colour choice, see page 25. 2) Powder coated1) Powder coated1) Aluminium If lighting profile in anodized finish is being used, powder coated stop end in ’RAL 9007’ is recommended. Lighting accessories Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No. 4/11/50 5440 810 L35960 Jointing piece Used to joint lighting profile. Supplied with screws. FED-SSJ Aluminium Earthing clamp For bonding lighting profile, light fitting rail, and accessories to earth. Zinc passivated Steel 5590 500 L34520 TTI-JB Earth wire For bonding lighting profile, light fitting rail and accessories to earth. Green/Yellow L51170 TTI-JK 300 42 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Copper Length = 300mm 5590 505 Lighting Bed/Examining lamps Type/Description Colour/ Dimensions Finish A/B/C (mm) Art. No. Bed/Examining lamp, Luxo Supplement to the lamp unit MWU-LP. To be fixed on wall. Provided in 1100 mm armlength. White L=1100 6200 401 18W compact flourescent tube. With a two level switch for reading and night light. MWU-L18W White L=1100 6200 411 Standard light bulb (max 40W), socket E27 MWU-LE27 White L=1100 6200 416 Wall fixing MWU-L White 130/70/130 6200 501 L66030 L66020 13W compact flourescent tube. MWU-L13W Bed/Examining lamp, Sunnex Supplement to the MWU lighting unit. With flexible arm. Built-in 12 V transformer for 20 W halogen. Separate 12 V transformer (plug-in) for 50 W halogen. To be fixed on wall or on desk (screw fixed or with clamp). Halogen lamp included. L=900 6200 420 12V/50W halogen lamp, plug-in transformer White L=900 6200 425 Wall fixing White 6200 505 Desk fixing (clamped) White 6200 535 L50860 L50520 L50510 L50600 L50590 12 V/20W halogen lamp, built-in transformer White 12 V/20 W halogen lamp (spare part) 12 V/50 W halogen lamp (spare part) 6200 610 6200 615 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 43 Gas Gas outlets Type/ Dimensions Description A/B/C (mm) Art. No. Gas outlets, AGA MC 70 Gas outlet with self-closing gas-type coded outlet valve and name plate in the colour code of the gas type. The outlets are supplied with a protective plug to prevent impurities from penetrating into the outlets when they are not connected. To be mounted onto the fixing profile. A mounting adaptor is to be used (ordered separately). Gas pipe, copper ∆ 8 mm, soldered on the inlet tube of the gas outlet. L50740 Breathing oxygen Nitrous oxide Breathing air, 4 bar Gas exit Vacuum Instrumental air, 7 bar 90/68/90 6100 6100 6100 6100 6100 6100 500 505 510 515 520 525 Gas outlet, Greggersen Gas outlet with self-closing gas-type coded outlet valve and name plate in the colour code of the gas type according to DIN. To be mounted onto the fixing profile. A mounting adaptor is to be used (ordered separately). Gas pipe, copper ∆ 8 mm, soldered on the inlet tube of the gas outlet. L50730 Breathing oxygen Nitrous oxide Breathing air, 4 bar Vacuum Instrumental air, 7 bar CO2 40/57/40 6100 6100 6100 6100 6100 6100 530 535 540 545 550 555 Gas outlet, Dräger Gas outlet with self-closing gas-type coded outlet valve and name plate in the colour code of the gas type according to DIN. To be mounted onto the fixing profile. Mounting adaptor is to be used (ordered separately). Gas pipe, copper ∆ 8 mm, soldered on the inlet tube of the outlet. L50720 Breathing oxygen Nitrous oxide Breathing air, 4 bar Vacuum CO2 64/72/74 6100 6100 6100 6100 6100 560 565 570 575 580 L50570 O Gas outlet, MEDÆS, GEM 10 Gas outlet with self-closing gas-type coded outlet valve and name plate in the colour code of gas type according to BS 5682. To be mounted directly onto the fixing profile (no mounting adaptor is required). Gas pipe, copper ∆ 12 mm, soldered on the inlet tube of the gas outlet. X YG EN Breathing oxygen Nitrous oxide Breathing air, 4 bar Vacuum Instrumental air, 7 bar Entonox 56/67/90 6100 6100 6100 6100 6100 6100 590 595 600 605 620 625 MWU-GA for for for for AGA MC65 AGA MC70 Dräger Greggersen L50640 L57530 Mounting adaptor kit To be used when fixing AGA, Dräger or Greggersen gas outlets to the fixing profile. Complete with screws. Mounted between gas outlet and the fixing profile. Material PA 44 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Black Black Black Black 72/6,5/50 77/8,5/71 77/8,5/71 77/8,5/71 6100 6100 6100 6100 801 802 803 804 Gas Fixing profile and Front covers Type/ Description Colour/ Finish Dimensions A/B/C (mm) Art. No. L50750 Fixing profile, gas outlets To mount gas outlets on to. Wall mounted. For AGA, Greggersen and Dräger gas outlets a mounting adapter is used between the gas outlets and the fixing profile. Medæs outlets are fixed directly to the fixing profile. For 1–4 gas outlets. Material: Aluminium. MWU-GF1, MWU-GF2, MWU-GF3, MWU-GF4, for1 outlet for 2 outlets for 3 outlets for 4 outlets Untreated 104,2/11,5/300 104,2/11,5/500 104,2/11,5/700 104,2/11,5/900 Front cover, gas outlet, AGA Front cover to suit AGA MC70 gas outlets. Snap-fitted on to fixing profile2). For 1-4 gas outlets with a c/c measure of 200 mm. Material: Aluminium. MWU-GU1, for 1 outlet MWU-GU2, for 2 outlets L50830 MWU-GU3, for 3 outlets MWU-GU4, for 4 outlets Anodized Powder coated1) Anodized Powder coated1) Anodized Powder coated1) Anodized Powder coated1) 110/71,5/300 110/71,5/500 110/71,5/700 110/71,5/900 Front cover, gas outlet, Greggersen Front cover to suit Greggersen gas outlets. Snap-fitted on to fixing profile2). For 1–4 gas outlets with a c/c measure of 200 mm. Material: Aluminium. MWU-GU1, for 1 outlet MWU-GU2, for 2 outlets L50840 MWU-GU3, for 3 outlets MWU-GU4, for 4 outlets Anodized Powder coated1) Anodized Powder coated1) Anodized Powder coated1) Anodized Powder coated1) 110/71,5/300 110/71,5/500 110/71,5/700 110/71,5/900 6100 6100 6100 6100 200 201 202 203 Ø = 75 mm 6100 6100 6100 6100 6100 6100 6100 6100 222 221 227 226 232 231 237 236 Ø = 42 mm 6100 6100 6100 6100 6100 6100 6100 6100 252 251 257 256 262 261 267 266 Front cover, gas outlet, Dräger Ø = 60 mm Front cover to suit Dräger and AGA MC65 gas outlets. Snap-fitted on to fixing profile2). For 1-4 gas outlets with a c/c measure of 200 mm. Material: Aluminium. MWU-GU1, for 1 outlet MWU-GU2, for 2 outlets L50770 MWU-GU3, for 3 outlets MWU-GU4, for 4 outlets Anodized Powder coated1) Anodized Powder coated1) Anodized Powder coated1) Anodized Powder coated1) 110/71,5/300 110/71,5/500 110/71,5/700 110/71,5/900 Front cover, gas outlet, MEDÆS, GEM 10 Front cover to suit Medæs gas outlets. Snap-fitted on to fixing profile2). For 1–4 gas outlets with a c/c measure of 200 mm. Material: Aluminium. MWU-GU1, for 1 outlet MWU-GU2, for 2 outlets L50770 MWU-GU3, for 3 outlets 1) 2) MWU-GU4, for 4 outlets Anodized Powder coated1) Anodized Powder coated1) Anodized Powder coated1) Anodized Powder coated1) 110/71,5/300 110/71,5/500 110/71,5/700 110/71,5/900 6100 6100 6100 6100 6100 6100 6100 6100 282 281 287 286 292 291 297 296 Ø = 52 mm 6100 6100 6100 6100 6100 6100 6100 6100 312 311 317 316 322 321 327 326 Colour choice, see page 25. For gas outlet installation techniques, see page 22. FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 45 Gas Front cover, Wall bracket, Stop ends Type/ Description Colour/ Finish Dimensions A/B/C (mm) Art. No. L50790 Front cover, gas pipe To conceal gas pipe installation. Front cover is snap-fitted to the wall brackets. Available cut to length, max 5.0 m by special order. Material: Aluminium. MWU-GP Anodized Powder coated1) 110/71,5/2500 6100 002 6100 001 L50760 Wall bracket, gas pipe front cover Front cover to gas pipe is snap-fitted to the wall bracket. Recommended distance between the wall brackets 600 mm. Stud partition wall – adjust the bracket distance according to the studding. Gas pipes to be fixed on the wall brackets. Material: Aluminium. MWU-GB Untreated 104,2/11,5/50 6100 090 L50660 Stop ends To be fixed on to the gas pipe cover or on to the gas outlet front cover2). The stop end is fixed with screws. Supplied with screws. Material: Aluminium. MWU-GE, left MWU-GE, right Powder coated1) Powder coated1) 109,6/71,6/2 6100 051 6100 056 L50690 Stop ends To be fixed on to the gas pipe cover or on to the gas outlet front cover2). With outlet for TRL gas pipe cover. The stop end is fixed with screws. Supplied with screws. Material: Aluminium. MWU-GE, left TRL5630 MWU-GE, right TRL5630 Powder coated1) Powder coated1) 109,6/71,6/2 6100 071 6100 076 MWU-GE, left TRL5656 MWU-GE, right TRL5656 Powder coated1) Powder coated1) 6100 061 6100 066 MWU-GE, left TRL7640 MWU-GE, right TRL7640 Powder coated1) Powder coated1) 6100 081 6100 086 L12740 Cover for gas pipe To conceal gas pipe installation. Cover is snap-fitted on TRL socket clamps. Material: Aluminium. TRL-D5630 TRL-D5656 TRL-D5656 TRL-D7640 Anodized Anodized Powder coated1) Anodized 56/30/2500 56/56/2500 56/56/2500 76/40/2500 5321 5321 5321 5321 100 120 122 210 Base clamp (with ties) To fix gas pipes and to mount cover onto. The bracket is screw fixed to the wall surface. Material: PA. TRL-H56 TRL-H76 Black –/–/– 5322 010 5322 020 Black 7/140/- 5322 050 60/57/30 5322 122 L12750 Tie (loose) TRL-T L12770 Stop end For terminating TRL gas pipe covers. Material: ABS. 1) 2) TRL-ES5656 Grey Colour choice, see page 25. If front cover, gas profile in anodized finish is being used, powder coated stop end in ’RAL 9007’ is recommended. 46 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Gas Gas accessories L50810 Type/ Description Colour/ Finish L50800 Dimensions A/B/C (mm) Art. No. Mounting plate with pipe clamps Gas pipes are snap-fitted into the clamps. For gas pipes in dimensions of Ø 8, 10 and 12 mm. Pipe clamps are fixed by screws onto the mounting plate. The complete pipe clamp unit is screw fixed to wall brackets. Supplied with screws. MWU-GA 4 x Ø 8 mm L50630 Material PE 77/24/53 6100 810 MWU-GA 2 x 2 Ø 10 mm 77/27/53 6100 811 MWU-GA 2 x 2 Ø 12 mm 77/29/53 6100 812 Earthing clamp For bonding the front cover gas outlet profile, gas outlets and accessories to earth. Zinc passivated Steel 5590 500 L34520 TTI-JB Earth wire For bonding the front cover, gas outlet profile, gas outlets and accessories to earth. Green/Yellow Copper L = 300 mm 5590 505 L51170 TTI-JK300 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 47 Accessory rail Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No. Accessory rail, Scandinavian type For hanging hospital equipment or instruments on. The rail must not be mounted on the hospital trunking. To be mounted directly on the wall surface, preferably below the hospital trunking, by using mounting brackets,which are screwed to the wall. The Accessory rail is snap-fitted to the mounting bracket. Recommended distance between mounting brackets; 400 mm. Stud partition wall – adjust the bracket distance according to studding. The Accessory rail is compatible with the AGA Accessory rail system. Dimension 30 x 10 mm. Anodized Aluminium 30/9,8/2500 6100 820 MWU-AB, bracket Anodized Aluminium 30/38/50 6100 830 MWU-AA, cap Grey PP 37/16/20 6100 825 L50850 L50680 L50650 MWU-AP, rail L59020 Accessory rail, DIN type For hanging hospital equipment or instruments on. The rail must not be mounted on the hospital trunking. To be mounted directly on the wall surface, over or below the hospital trunking. The rail brackets are pre-mounted on the wall. Complete with screws. The rail is compatible with the DIN-standards. Dimension 25 x 10 mm. Maximum load 100 kg/m mounted on a solid wall. Available autumn 1999. MWU-AP, rail Untreated SS 25/10/2000 6100 840 L59010 DIN-rail shelf To be mounted on the accessory rail, DIN type. For hospital equipment such as monitors. Carries up to 40 kg (400 N). Available autumn 1999. MWU-AS Grey 48 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 SS 170/369/540 6100 845 Tools Type/ Description Colour/ Finish Material Dimensions A/B/C (mm) Art. No. D11130 Electrical cutting saw Used to cut aluminium profiles. Maximum cutting 90x220mm. Spare blade available. Jepson Dry Cutter V-Power, type KA-M335. ISV-KS Blade Steel 5900 055 5900 056 L35480 Radial arm cutting saw with work-table Used to cut aluminium profiles. Maximum cutting height x depth = 90 x 300 mm. DeWalt DW 8003. ISV–SG217 Steel 5900 040 L10770 Mitre box To cut aluminium profiles at any angle. Complete with saw. Maximum cutting height x depth = 120x170 mm. ISV-G400 Aluminium 490/260/645 5900 000 Steel 550/45/1 5900 001 Saw blade Replacement blade for saw ISV-G400. L10720 ISV-GS550 L50620 Plunge tool To make a Ø 18.6 mm hole for the edge protection grommet INKA-GF19. The plunge tool is used to make a hole for cables between trunking base and lighting profile. ISV-HS Steel 5900 020 Jig template For the mounting of cable trunking. Prevents scratching when drilling machine is used. Steel 80/40/12 5900 130 L12560 INKA-JT Front cover opener For removing the front cover without damaging the trunking base or front cover. Blue PA 100/160 5900 900 L32330 ISV FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 49 Cable Capacity Guide (CCG) Approximate calculation for dimensioning cable trunking The CCG diagram is a quick and simple way of working out the minimum dimensions of the installation trunking for a given number of cables. If the cables are to be laid in different compartments in the same trunking, the total height of the trunking will be the sum of the compartment heights. This is how to use the CCG diagram: 1. Read the diagram clockwise 2. Choose the number of cables (N) on the upper vertical scale in the middle of the diagram 3. Go to the right in the diagram up to the red line that corresponds to the relevant cable diameter (D). Directly below the intersection point you can read off the total cable area (A) on the right-hand horizontal scale. If there are cables with different diameters, the total cable area (A) is the sum of the cable areas for the various cable diameters. 4. Now continue down from the intersection point for total cable area to the line that corresponds to the desired fill factor. 5. Directly to the left of the intersection point you can read off a suitable trunking area (S) on the lower vertical scale. 6. Then continue to the left from the value for trunking area to the line that corresponds to the desired trunking depth for trunking with or without flush boxes (if the trunking is used as feeder trunking). 7. Go straight up from the intersection point and read off on the lefthand horizontal scale the smallest trunking height (H) that is required to run the cables. H (mm) Trunking height Trunking depth (mm) 250 200 A number of cables are to be laid in installation trunking fitted with a cable shelf so that power cables and low-current cables can be kept separate. Known data: Power cables: 10 cables of 20 mm diameter (the lower green line in the upper part of the diagram) Low-current cables: 22 cables of 12 mm diameter (the upper green line) The installation trunking must be 90 mm deep, without boxes and be 60 % filled. Calculated data: The cable area (A) for the low-current will be about 3350 mm2. For a 60% fill factor this cable area gives a compartment area (S) of about 5600 mm2. This means that the minimum height (H) of the compartment where the cables will run is about 60 mm (trunking without box). The cable area (A) for the power cables will be about 4600 mm2. For a 60% fill factor this cable area (S) gives a compartment area of about 7700 mm2. This means that the minimum height (H) of the compartment where the cables will run is about 85 mm (trunking without box). Suitable installation trunking should therefore be higher than 145 mm (the sum of 60 mm for the low current cable compartment and 85 mm for the power cable compartment). The final choice of installation trunking is made with the aid of the list of our range of trunking (page 16-17) and the associated detailed cable capacity tables (pages 52-58). 150 52 52 72 72 90 90 Trunking without box Example 130 130 Trunking with box 50 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 100 50 N Number of cables ø3 ø4 ø5 50 ø6 48 ø7 ø8 ø9 46 ø10 44 D (mm) Cable diameter ø11 42 ø12 40 Ø ø13 38 36 ø14 34 ø15 32 30 ø16 28 ø17 26 ø18 24 ø19 22 ø20 20 18 16 14 12 10 8 6 A (mm ) 2 4 Total cable area 2 1000 2000 3000 4000 5000 6000 7000 8000 9000 1 2 3 4 5 6 7 8 Trunking fill factor 9 10 80% 11 12 13 60% 14 15 50% 16 17 40% 18 19 20 21 22 23 24 25 S x 1000 (mm ) 2 Trunking/Compartment area © THORSMAN & CO AB, 1997. FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 51 Cable Capacity Height* Cross section area mm2 Cable capacity mm2 40% 50% 60% Without mounting boxes 1 2 3 4 5 6 7 8 96 Not applicable Not applicable Not applicable 23 25 25 23 20 Not applicable Not applicable Not applicable 15 15 15 20 2226 2783 3339 1303 1199 1199 1308 521 480 480 523 652 600 600 654 782 719 719 785 3580 1432 1790 2148 30 Not applicable Not applicable Not applicable 20 20 20 20 Cross section area mm2 Cable capacity mm2 40% 50% 60% 1037 522 522 1025 415 209 209 410 519 261 261 513 622 313 313 615 1 2 3 4 5 6 7 8 96 Not applicable Not applicable Not applicable 23 25 25 23 7152 2861 3576 4291 1521 1641 1641 1764 608 656 656 706 761 821 821 882 913 985 985 1058 5010 2004 2505 3006 1218 975 975 1389 487 390 390 556 609 488 488 695 731 585 585 833 With standard mounting boxes With mounting box CYB 30 mm deep 1 2 3 4 5 6 7 8 Height* Without mounting boxes 5565 With standard mounting boxes 1 2 3 4 5 6 7 8 Comp No 1 2 3 4 5 6 7 8 40 Not applicable Not applicable Not applicable 20 20 20 20 With mounting box CYB 30 mm deep (Fig C, B, A) 4171 1668 2086 2503 1102 752 752 1092 441 301 301 437 551 376 376 546 661 451 451 655 R32430 * Internal compartment height 52 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 1 2 3 4 5 6 7 8 50 Not applicable Not applicable Not applicable 20 20 20 20 5754 2302 2877 3452 1348 1198 1198 1506 539 479 479 602 674 599 599 753 809 719 719 904 * Internal compartment height R33210 Comp No R37580 R37580 INKA-101/90 R37580 R37580 INKA-101/72 Cable Capacity INKA-123-4/72 R37580 R37580 R37580 R37580 INKA-123/72 Height* Cross section area mm2 Cable capacity mm2 40% 50% 60% Without mounting boxes 1 2 3 4 5 6 7 8 118 Not applicable Not applicable Not applicable 34 25 25 34 20 Not applicable Not applicable Not applicable 20 15 15 20 2520 3151 3781 1912 1199 1199 1709 765 480 480 684 956 600 600 855 1147 719 719 1025 4786 1914 2393 2872 30 Not applicable Not applicable Not applicable 25 20 20 25 1637 522 522 1664 655 209 209 666 819 261 261 832 982 313 313 998 R32480 Cable capacity mm2 40% 50% 60% 1 2 3 4 5 6 7 8 118 Not applicable Not applicable Not applicable 33 25 25 33 6857 2743 3429 4114 1865 1199 1199 2089 746 480 480 836 933 600 600 1045 1119 719 719 1253 1 2 3 4 5 6 7 8 25 Not applicable Not applicable Not applicable 20 15 15 20 4706 1882 2353 2824 1597 522 522 1669 639 209 209 668 799 261 261 835 958 313 313 1001 With mounting box CYB 30 mm deep 5362 2145 2681 3217 1701 752 752 1718 680 301 301 687 851 376 376 859 1021 451 451 1031 * Internal compartment height Cross section area mm2 With standard mounting boxes With mounting box CYB 30 mm deep 1 2 3 4 5 6 7 8 Height* Without mounting boxes 6301 With standard mounting boxes 1 2 3 4 5 6 7 8 Comp No 1 2 3 4 5 6 7 8 35 Not applicable Not applicable Not applicable 30 20 20 25 5499 2200 2750 3299 1717 752 752 1794 687 301 301 718 859 376 376 897 1030 451 451 1076 * Internal compartment height R33220 Comp No FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 53 Cable Capacity R37580 R37580 INKA-123/90 Comp No Height* Cross section area mm2 Cable capacity mm2 40% 50% 60% Without mounting boxes 1 2 3 4 5 6 7 8 118 Not applicable Not applicable Not applicable 34 25 25 34 8823 3529 4412 5294 2388 1199 1199 2602 955 480 480 1041 1194 600 600 1301 1433 719 719 1561 With standard mounting boxes (Fig C, B, A) 1 2 3 4 5 6 7 8 40 Not applicable Not applicable Not applicable 20 20 20 20 6680 2672 3340 4008 2087 975 975 2227 835 390 390 891 1044 488 488 1114 1252 585 585 1336 With mounting box CYB 30 mm deep (Fig C, B, A) 1 2 3 4 5 6 7 8 50 Not applicable Not applicable Not applicable 20 20 20 20 7424 2970 3712 4454 2215 1198 1198 2344 886 479 479 938 1108 599 599 1172 1329 719 719 1406 R33230 * Internal compartment height 54 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Cable Capacity R37920 R37920 INKA-161-2/90 R37920 R37920 INKA-161-2/72 Height* Cross section area mm2 Cable capacity mm2 40% 50% 60% Without mounting boxes 1 2 3 4 5 6 7 8 9 108 Not applicable Not applicable Not applicable 34 25 25 23 48 20 Not applicable Not applicable Not applicable 20 15 15 20 2440 3051 3661 1925 1199 1199 1273 2740 770 480 480 509 1096 963 600 600 637 1370 1155 719 719 764 1644 3914 1566 1957 2348 30 Not applicable Not applicable Not applicable 25 20 20 20 1651 522 522 1001 660 209 209 400 826 261 261 501 991 313 313 601 R32500 Cable capacity mm2 40% 50% 60% 1 2 3 4 5 6 7 8 9 108 Not applicable Not applicable Not applicable 34 25 25 23 48 7982 3193 3991 4789 2388 1199 1199 1747 3468 955 480 480 699 1387 1194 600 600 874 1734 1433 719 719 1048 2081 1 2 3 4 5 6 7 8 40 Not applicable Not applicable Not applicable 20 20 20 20 5839 2336 2920 3503 2087 975 975 1372 835 390 390 549 1044 488 488 686 1252 585 585 823 With mounting box CYB 30 mm deep 4704 1882 2352 2822 1713 752 752 1052 685 301 301 421 857 376 376 526 1028 451 451 631 * Internal compartment height Cross section area mm2 With standard mounting boxes With mounting box CYB 30 mm deep 1 2 3 4 5 6 7 8 Height* Without mounting boxes 6101 With standardmounting boxes 1 2 3 4 5 6 7 8 Comp No 1 2 3 4 5 6 7 8 50 Not applicable Not applicable Not applicable 20 20 20 20 6584 2634 3292 3950 2215 1198 1198 1489 886 479 479 596 1108 599 599 745 1329 719 719 893 * Internal compartment height R33250 Comp No FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 55 Cable Capacity INKA-161-3/90 Height* Cross section area mm2 Cable capacity mm2 40% 50% 60% Without mounting boxes 1 2 3 4 5 6 7 8 157 Not applicable Not applicable Not applicable 34 25 25 72 20 Not applicable Not applicable Not applicable 20 15 15 40 3748 4685 5621 1909 1199 1199 4556 764 480 480 1822 955 600 600 2278 1145 719 719 2734 7372 2949 3686 4423 30 25 25 40 25 20 20 40 1620 522 522 4273 648 209 209 1709 810 261 261 2137 972 313 313 2564 3989 773 438 2276 850 376 376 2172 4787 927 526 2731 1019 451 451 2606 7978 1545 876 4552 1699 752 752 4343 Cross section area mm2 Cable capacity mm2 40% 50% 60% 1 2 3 4 5 6 7 8 157 Not applicable Not applicable Not applicable 34 25 25 72 12149 4860 6075 7289 2433 1632 1632 5888 973 653 653 2355 1217 816 816 2944 1460 979 979 3533 10115 4046 5058 6069 1658 958 958 5562 663 383 383 2225 829 479 479 2781 995 575 575 3337 With standard mounting boxes With mounting box CYB 30 mm deep 1 2 3 4 5 6 7 8 Height* Without mounting boxes 9369 With standard mounting boxes 1 2 3 4 5 6 7 8 Comp No 3191 618 350 1821 680 301 301 1737 1 2 3 4 5 6 7 8 67 Not applicable Not applicable Not applicable 31 23 23 67 With mounting box CYB 30 mm deep R32780 * Internal compartment height 56 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 1 2 3 4 5 6 7 8 67 Not applicable Not applicable Not applicable 31 23 23 67 10750 4300 5375 6450 1754 1185 1185 5640 702 474 474 2256 877 593 593 2820 1052 711 711 3384 * Internal compartment height R33260 Comp No R37580 R37580 R37580 R37580 INKA-161-3/72 Cable Capacity Height* Cross section area mm2 Cable capacity mm2 40% 50% 60% Without mounting boxes 1 2-4 5 6 7 8 9 10 11 108 Not applicable 34 25 25 22 70 32 39 40 Not applicable 20 20 20 20 30 25 30 3193 3991 4789 2388 1199 1199 1747 5391 2130 3054 955 480 480 699 2156 852 1222 1194 600 600 874 2696 1065 1527 1433 719 719 1048 3235 1278 1832 5839 2336 2920 3503 2087 975 975 1372 5391 2130 3054 835 390 390 549 2156 852 1222 1044 488 488 686 2696 1065 1527 1252 585 585 823 3235 1278 1832 With mounting box CYB 30 mm deep 1 2-4 5 6 7 8 9 10 11 50 Not applicable 20 20 20 20 30 25 30 6584 2634 3292 3950 2215 1198 1198 1489 5391 2130 3054 886 479 479 596 2156 852 1222 1108 599 599 745 2696 1065 1527 1329 719 719 893 3235 1278 1832 * Internal compartment height Height* Cross section area mm2 Cable capacity mm2 40% 50% 60% Without mounting boxes 7982 With standard mounting boxes 1 2-4 5 6 7 8 9 10 11 Comp No 1 2-4 5 6 7 8 9 10 - 11 12 13 14 15 16 105 Not applicable 33 25 25 20 105 Not applicable 30 20 25 25 33 5962 2385 2981 3577 1905 1199 1199 1130 6010 762 480 480 452 2404 953 600 600 565 3005 1143 719 719 678 3606 1766 1082 1199 1199 1985 706 433 480 480 794 883 541 600 600 993 1060 649 719 719 1191 3980 1592 1990 2388 1614 476 476 843 4014 646 190 190 337 1606 807 238 238 422 2007 968 286 286 506 2408 1409 807 476 476 1699 564 323 190 190 680 705 404 238 238 850 845 484 286 286 1019 With standard mounting boxes 1 2-4 5 6 7 8 9 10 - 11 12 13 14 15 16 20 Not applicable 20 15 15 20 20 Not applicable 25 15 15 15 25 With mounting box CYB 30 mm deep 1 2-4 5 6 7 8 9 10 - 11 12 13 14 15 16 30 Not applicable 25 20 20 25 30 Not applicable 25 15 15 15 25 4568 1827 2284 2741 1696 752 752 911 4616 678 301 301 364 1846 848 376 376 456 2308 1018 451 451 547 2770 1580 883 752 752 1766 632 353 301 301 706 790 442 376 376 883 948 530 451 451 1060 R33280 * Internal compartment height R33170 Comp No R37360 R37700 INKA-217-2/72 R37360 R37360 INKA-183-2/90 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 57 Cable Capacity R37700 R37700 INKA-217-2/90 Comp No Height* Cross section area mm2 Cable capacity mm2 40% 50% 60% Without mounting boxes 1 2-4 5 6 7 8 9 10 -12 13 14 15 16 105 Not applicable 33 25 25 20 105 Not applicable 20 25 25 33 7745 3098 3873 4647 2388 1199 1199 1567 7819 955 480 480 627 3128 1194 600 600 784 3910 1433 719 719 940 4691 1358 1199 1199 2619 543 480 480 1048 679 600 600 1310 815 719 719 1571 5602 2241 2801 3361 1087 975 975 1191 5676 435 390 390 476 2270 544 488 488 596 2838 652 585 585 715 3406 1055 975 975 2244 422 390 390 898 528 488 488 1122 633 585 585 1346 With standard mounting boxes 1 2-4 5 6 7 8 9 2-4 13 14 15 16 40 Not applicable 20 20 20 20 40 Not applicable 15 20 20 30 With mounting box CYB 30 mm deep 1 2-4 5 6 7 8 9 2-4 13 14 15 16 50 Not applicable 20 20 20 20 40 Not applicable 15 20 20 30 6346 2538 3173 3808 2215 1198 1198 1309 6472 886 479 479 524 2589 1108 599 599 655 3236 1329 719 719 785 3883 1186 1198 1198 2361 474 479 479 944 593 599 599 1181 712 719 719 1417 R33290 * Internal compartment height 58 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Technical Data Chemical Resistance Aluminium (Al) is resistant to most first acids and organic solvents. Aluminium is not resistant to most strong acids (except nitric acid) and alkali. PVC According to ISO Technical report 7473 1981, PVC (polyvinylchloride, uPVC) is resistant to most acids, lyes, salt solutions and hydrous organic combinations. PVC is not resistant to aromatic and chlorinated solvents, e.g. acetone, thinner, trichloreethylene, ethyl acetate, tetrahydrofurane, metylene chloride, metyl ethyl ketone. Material data Material data Density Longitudinal expansion Water absorption Volume resistivity Electrical strength Fire class PC 1.17 g/cm3 70x10-6 m/m°C 0.6% >1013 Ω cm 18 kV/mm UL 94 V-2, 1.6 mm halogen-free Material data Density Longitudinal expansion Water absorption Volume resistivity Electrical strength Fire class PA 1.39 g/cm3 100x10-6 m/m°C 2.8% >1015 Ω cm 60 kV/mm UL 94 HB, halogen-free Material data Density Longitudinal expansion Water absorption Volume resistivity Electrical strength Fire class PC/ABS 1.14 g/cm3 – 0.6% >1013 Ω cm 19 kV/mm UL 94 V-0, 1.6 mm halogen-free Material data Density Longitudinal expansion Water absorption Volume resistivity Electrical strength Fire class PMMA 1.19 g/cm3 80x10-6 m/m°C 0.3% >1015 Ω cm 30 kV/mm (DIN 53481) UL 94 HB, 1.6 mm halogen-free Material data Density Longitudinal expansion Water absorption Volume resistivity Electrical strength Fire class PP 0.905 g/cm3 100x10–6 m/m°C <0,1% 1012 Ω cm >30 kV/mm UL 94 HB halogen-free, withstands glow wire test 750° Material data Density Longitudinal expansion Water absorption Volume resistivity Electrical strength Fire class Aluminium 2.7 g/cm3 24x10–6m/m°C (0.024 mm/m°C) - Material data Density Longitudinal expansion Water absorption Volume resistivity Electrical strength Temperature resistance: PVC ISO 1183 1.5 g/cm3 60x10–6 m/m°C (0.06 mm/m°C) Maximum 60°C FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 59 Mounting Details M38540 TTA-KM 1 TTA-KM 3 TTA-KM 5 60 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Mounting details ISV-FO FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 61 Mounting details TTI-JB 62 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Mounting details x2 2 1 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 63 Mounting details MWU-LS Optional 225 225 = = MI2072 10 mm 64 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Mounting details MWU-GA FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 65 MI2073 66 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Specification Guide Due to the great flexibility of the FrontLine Hospital Trunking system and the many possibilities for combining the various products, we recommend the following procedure when specifying/ordering: General 1. 2. 3. 4. 5. 6. Service carrier Service Content Lighting Gas Accessory rail Tools P3826 All items are presented in the same order they appear in this brochure. Information given in the order form under Type/Description is somewhat restricted due to space considerations. For colour choice, fill in the corresponding colour code (for example L11), see page 25. Numbers in parentheses, for example (p. 26-27), refer to pages in this brochure. Begin by copying the Specification/Order form, then choose: FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 67 Specification/Order form (Copy this form before filling in) 2. Service content 1. Service carrier Art. No. T- Type/Description (p 26-27) Trunking bases 5504 5504 5507 5507 5506 5506 5510 5510 5510 5510 5514 5514 000 002 000 002 310 319 010 012 020 022 000 002 5519 5519 5506 5506 5519 5519 5512 5512 5519 5519 5519 5519 010 012 400 402 020 022 230 232 060 062 040 042 INKA-U101, anodized INKA-U101, colour code: INKA-U123, anodized INKA-U123, colour code: INKA-U161-2, anodized INKA-U161-2, colour code: INKA-U161-3, anodized INKA-U161-3, colour code: INKA-U183-2, anodized INKA-U183-2, colour code: INKA-U217-2, anodized INKA-U217-2, colour code: 030 039 080 089 Front covers FCA-F40, anodized FCA-F40, colour code: FCA-F80, anodized FCA-F80, colour code: 172 172 172 172 217 152 277 062 032 307 203 208 Stop ends* INKA-ES101/72, colour code: INKA-ES123/72, colour code: INKA-ES161/72, colour code: INKA-ES217/72, colour code: INKA-ES101/90, colour code: INKA-ES123/90, colour code: INKA-ES161-2/90, colour code: INKA-ES161-3/90, colour code: INKA-ES183-2/90, colour code: INKA-ES217-2/90, colour code: INKA-ESV123-4/72, left, colour code: INKA-ESH123-4/72, right, colour code: Qty (pcs) Art. No. T- Type/Description (p 30) Connection kits, Schuko INKA-U101, anodized INKA-U101, colour code: INKA-U123, anodized INKA-U123, colour code: INKA-U123-4, anodized INKA-U123-4, colour code: INKA-U161-2, anodized INKA-U161-2, colour code: INKA-U161-3, anodized INKA-U161-3, colour code: INKA-U217-2, anodized INKA-U217-2, colour code: 5975 000 5975 005 CYB-PS, white CYB-PS, white 5951 5951 5951 5951 480 482 485 487 CYB-PS, CYB-PS, CYB-PS, CYB-PS, 5951 5951 5951 5951 430 432 435 437 90 mm deep (p 31) CYB-PS, white CYB-PS, red CYB-PS, green CYB-PS, ornage Connection kits, French Standard 5969 215 5969 217 CYB-PF, Two-gang, push-in terminals, white CYB-PF, Two-gang, push-in terminals, red 5969 210 5969 212 CYB-PF, Two-gang, screw terminals, white CYB-PF, Two-gang, screw terminals, red 5969 5969 5969 5969 (p 31) CYB-PF, Two-gang, push-in terminals, white CYB-PF, Two-gang, push-in terminals, red CYB-PF, Two-gang, screw terminals, white CYB-PF, Two-gang, screw terminals, red Connection kits, British Standard 5961 130 5961 120 5961 140 CYB-PU, switched, white CYB-PU, switched, white CYB-PU, switched with indicator, white 5961 135 5961 125 5961 145 CYB-PU, unswitched, white CYB-PU, switched , white CYB-PU, switched with indicator, white Basic kit, CEE socket outlets CYB-C220, 250 V/16 A, grey/blue CYB-C380, 440 V/16 A, grey/red 72 mm deep (p 27) 5580 5580 5580 5580 (p 28) 5504 5507 5510 5514 5590 5591 5590 5591 5591 5590 5590 5590 (p 28-29) 5590 5590 5590 5590 5590 5590 5590 5590 5590 5590 5590 5590 5902 5902 5586 5583 5583 5583 312 314 315 316 340 180 112 500 505 410 414 520 100 120 600 405 408 410 Trunking accessories TTI-KH72, Cable shelf, aluminium TTI-KH72, Cable shelf, PVC TTI-KH90, Cable shelf, aluminium TTI-KH90, Cable shelf, PVC TTI-KHK, Cable clip TTI-MB, Mounting washer INKA-SSA, Jointing piece TTI-JB, Earthing clamp TTI-JK300, Earth wire TTI-T3045, Sound insulation strip TTI-T5070, Sound insulation strip TTI-KB, Cup washer INKA-GF19, Grommet INKA-KD82, Edge protection TTI-GM, Locking plate TTA-KM1, Washer TTA-KM3, Washer TTA-KM5, Washer 68 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Qty (pcs) Single socket outlets, Schuko 90° Double socket outlets, Schuko 37° white red green orange Three-gang socket outlets, Schuko 37° For Poland and France For Belgium, Poland, France For Czech Rep., Poland, France 115 117 110 112 Single, 13 A Twin, 13 A (p 32) 5960 110 5960 100 002 007 012 017 032 052 062 072 082 087 057 Connection kit, Overvoltage protection CYB-PP, white Connection kits, Switches CYB-PB, Single-pole CYB-PB, Single-pole, spring-return rocker CYB-PB, Single-pole, red indicator lamp CYB-PB, Single-pole, green indicator lamp CYB-PB, Double-pole CYB-PB, Single-pole/two-way CYB-PB, Intermediate CYB-PB, Two-gang CYB-PB, Venetian blind CYB-PB, Venetian blind, single-pole CYB-PB, Double single-pole/two-way 5972 105 CYB-GL2, to be mounted together with switch 5972 200 CYB-PT, For single socket, 3x2,5 mm2 Light diode kit CYB-PO, angled, white (p 32) 5972 010 (p 32-33) 5980 5980 5980 5980 5980 5980 5980 5980 5980 5980 5980 Pilot lamp 0.9 mA 250 V Push-in plint for16A/250V (p 34) 5974 010 (p 34) 5985 5985 5985 5985 020 000 030 050 Connection kit, Dimmers 230 V, F80® Mounting CYB-PR, dimmer, white (APE 10T) CYB-PR, dimmer, white (ATD 300R) CYB-PR, dimmer, white (AD 400UTT) CYB-PR, dimmer, white (ATTD 1000RL) * If anodized trunking is chosen, stop ends in colour code L23 (RAL 9007) are recommended. Specification/Order form 2. Service content (cont.) 2. Service content (cont.) Art. no. T- Type/Description (p 34) Mounting boxes and blank covers CYB-S40, Single box CYB-D40, Double box CYB-PL, Blanking cover, single CYB-PL, Blanking cover, double 5961 5961 5961 5961 030 035 550 555 Qty (pcs) (p 35) Accessories for Mounting boxes and Mounting kits 5961 505 5961 506 CYB-P40, for British standard CYB-P3, for 60 mm centres Screw pillars Art. No. T- Type/Description (p 38-39) Connection kits, Data (cont.) 5970 5970 5970 5970 5970 5970 5970 5970 960 965 970 975 800 805 810 815 1 2 1 2 1 2 1 2 5970 5970 5970 5970 5970 5970 5970 5970 930 935 840 845 850 860 855 865 1 2 1 2 1 2 1 2 5970 5970 5970 5970 355 360 365 370 1x 2x 1x 2x Qty (pcs) Avaya (Lucent) MPS 300, 100 UTP x x x x x x x x Cat6 UTP, A, white Cat6 UTP, A, white Cat6 UTP, B, white Cat6 UTP, B, white Cat5e UTP, A, white Cat5e UTP, A, white Cat5e UTP, B, white Cat5e UTP, B, white AMP110, Netconnect UTP and STP Adapter for flexible conduit 5956 250 5956 255 CYB-D20, Adapter CYB-D25, Adapter 5961 500 CYB-ET, can take 2x4 mm2 wires 5961 510 CYB-CT 5956 150 FDS Earthing terminal Conduit bush Strain relief x x x x x x x x Cat6 A/B UTP, white Cat6 A/B UTP, white Cat5e A/B UTP, white Cat5e A/B UTP, white Cat5e A, STP, white Cat5e A, STP, white Cat5e B, STP, white Cat5e B, STP, white IBM ACS type C, Reichle de Massari UTP and FTP (p 35) Installation boxes 5586 150 5586 155 MIB-A1 MIB-A2 Cat5, Cat5, Cat5, Cat5, UTP, white UTP, white FTP, white FTP, white IBM type 1, STP for structured cable systems (p 36) 5971 790 5971 794 Mounting kit for access. CYB-MB CYB-MB (other suppliers) 5970 345 1x IBM type 1, white 5970 350 1x IBM type 2, white 5970 5970 5970 5970 1 2 1 2 IBM type 2, STP for structured cable systems Krone Keystone for PremisNET struct. cable syst. (p 36) 5971 5971 5971 5971 302 301 307 306 5971 315 5914 050 (p 37) 5960 251 5960 256 (p 37) 5960 5960 5960 5060 5960 5960 5960 5960 5960 5960 5960 5960 480 485 460 490 465 495 470 500 475 505 415 410 Equipotential connection CYB-PO, (max 63 A), anodized CYB-PO, colour code: CYB-PO DIN, anodized CYB-PO DIN, colour code: Equipotential connection Kit CYB-PO DIN CTA-PO DIN enclosures CYB-PN CYB-PN Circuit breakers CYB-PN, 1-pole, C10A CYB-PN, 1-pole, C16A CYB-PN, 2-pole, B10A CYB-PN, 2-pole, C10A CYB-PN, 2-pole, B16A CYB-PN, 2-pole, C16A CYB-PN, 3-pole, B10A CYB-PN, 3-pole, C10A CYB-PN, 3-pole, B16A CYB-PN, 3-pole, C16A CYB-PN 2 pole, Earth leakage breaker CYB-PN 4 pole, Earth leakage breaker (p 38-39) Connection kits, Data 5974 5974 5974 5974 5970 5970 5970 5970 1 2 1 2 1 2 1 2 LexCom 250, 125 UTP and STP 090 095 100 105 900 905 910 915 x x x x x x x x Cat6 UTP, A/B, white Cat6 UTP, A/B, white Cat6 STP, A/B, white Cat6 STP, A/B, white Cat5e UTP, A/B, white Cat5e UTP, A/B, white Cat5e STP, A/B, white Cat5e STP, A/B, white 760 765 770 775 x x x x Cat5 Cat5 Cat5 Cat5 UTP, B, white UTP, B, white STP, B, white STP, B, white (p 39) Connection kits, fibre optics 5974 000 5974 005 1 x SC-duplex, multimode, white 2 x SC-duplex, multimode, white 5970 375 5970 380 5970 385 2 x ST, multimode, white 1 x SC-duplex, multimode, white 2 x SC-duplex, multimode, white 5971 220 (p 40) CYB-DF, white Connection kits, Telephone 5970 520 5970 525 1x RJ45, white 2x RJ45, white 5970 510 5970 515 1x RJ11, white 2x RJ11, white (p 40) Connection kits, low current and coaxial cable networks, aerial, radio/TV 5970 595 5954 120 1 x radio/TV, white CAN-A75, termination resistor 5970 310 5970 315 5970 320 1 x D-sub 9-pole, white 1 x D-sub 15-pole, white 1 x D-sub 25-pole, white Accessories CYB-RK, high, Protective Casing, red CYB-RK, low, Protective Casing, red LexCom fibre multimode for fibre-based cable syst. AMP SC and Lucent Technologies ST Protective casing for fibre optics AMP 8-way modular socket Cat 3 AMP 6-way modular socket Connection kit, radio/TV aerial Connection kit, D-connectors (p 40) 5971 200 5971 205 ▲ FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 69 Specification/Order form 3. Lighting 4. Gas Art. No. T- Type/Description (p 41-42) Art. No. T- Type/Description Lighting profile, Light fitting rail, Covers, Stop ends (p 44) Gas outlets Lighting profile 6100 6100 6100 6100 6100 6100 500 505 510 515 520 525 Breathing oxygen Nitrous oxide Breathing air, 4 bar Gas exit Vacuum Instrumental air, 7 bar 6100 6100 6100 6100 6100 6100 530 535 540 545 550 555 Breathing oxygen Nitrous oxide Breathing air, 4 bar Vacuum Instrumental air, 7 bar CO2 6100 6100 6100 6100 6100 560 565 570 575 580 Breathing oxygen Nitrous oxide Breathing air, 4 bar Vacuum CO2 6100 6100 6100 6100 6100 6100 590 595 600 605 620 625 Breathing oxygen Nitrous oxide Breathing air, 4 bar Vacuum Instrumental air, 7 bar Entonox 801 802 803 804 Mounting adaptor kit MWU-GA for AGA MC65 MWU-GA for AGA MC70 MWU-GA for Dräger MWU-GA for Greggersen 6200 6200 6200 6200 002 001 006 005 MWU-LP, MWU-LP, MWU-LP, MWU-LP, 6200 6200 6200 6200 6200 6200 6200 6200 6200 6200 6200 6200 6200 6200 6200 6200 6200 150 151 210 211 212 205 206 200 201 160 165 225 230 245 250 240 220 MWU-LR, Type TC 18W MWU-LR, Type TC 18W, HF** MWU-LR, Type TC 36W MWU-LR, Type TC 36W, HF** MWU-LR, Type TC 36W, HF dimm.** MWU-LR, Type T26 36W MWU-LR, Type T26 36W, HF** MWU-LR, Type T26 58W MWU-LR, Type T26 58W, HF** MWU-LR, Type T5 28W, HF** MWU-LR, Type T5 54W, HF** T26, fluorescent std. Tube 36W, L=1200 T26, fluorescent std. Tube 58W, L=1500 T5, fluorescent std. Tube 28W, L=1149 T5, fluorescent std. Tube 54W, L=1149 TC, fluorescent compact Tube 18W, L=217 TC, fluorescent compact Tube 36W, L=410 Qty (pcs) anodized colour code: L=1250 mm, anodized L=1250 mm, colour code: Light fitting rail Pull-cord Switch 6200 301 MWU-LS 6200 291 6200 605 MWU-LA IBP/F 5 W bulb (dim) Night Light AGA MC 70 Greggersen Dräger MEDÆS, GEM 10 Light Diode Kit (p 44) 5974 010 CYB-PO, angled, white 6200 805 MWU-LC, transparent (p 42) Front cover 6100 6100 6100 6100 5580 080 5580 089 FCA-F80, anodized FCA-F80, colour code: (p 45) Up-light cover Fixing profile and Front covers Prismatic shade 6200 800 6200 801 MWU-LF, transparent (TC 36W) MWU-LF, transparent (TC 18W) 6200 051 6200 056 MWU-LE, left, colour code: MWU-LE, right, colour code: Stop end*, lighting profile 5440 810 5590 500 5590 505 Lighting accessories FED-SSJ, Jointing piece TTI-JB, Earthing clamp TTI-JK 300, Earth wire (p 43) Bed-Examining lamps 6200 401 6200 411 6200 416 6200 501 MWU-L13W compact flourescent tube MWU-L18W compact flourescent tube MWU-L 40W bulb Wall fixing 6200 420 6200 425 6200 505 6200 535 6200 610 6200 615 12 V/20W halogen lamp, built-in transformer 12V/50W halogen lamp, plug-in transformer Wall fixing Desk fixing (clamped) 12 V/20 W halogen lamp 12 V/50 W halogen lamp (p 42) Luxo Sunnex * If anodized lighting profile is chosen, stop ends in colour code L23 (RAL 9007) are recommended. ** HF=Electronic ballasts 70 FrontLine Hospital Trunking/Thorsman/MC1823INT/GB/0112 Qty (pcs) Fixing profile, gas outlets 6100 6100 6100 6100 200 201 202 203 MWU-GF1, MWU-GF2, MWU-GF3, MWU-GF4, 6100 6100 6100 6100 6100 6100 6100 6100 222 221 227 226 232 231 237 236 MWU-GU1, MWU-GU1, MWU-GU2, MWU-GU2, MWU-GU3, MWU-GU3, MWU-GU4, MWU-GU4, 6100 6100 6100 6100 6100 6100 6100 6100 252 251 257 256 262 261 267 266 MWU-GU1, MWU-GU1, MWU-GU2, MWU-GU2, MWU-GU3, MWU-GU3, MWU-GU4, MWU-GU4, 6100 6100 6100 6100 6100 6100 6100 6100 282 281 287 286 292 291 297 296 MWU-GU1, MWU-GU1, MWU-GU2, MWU-GU2, MWU-GU3, MWU-GU3, MWU-GU4, MWU-GU4, for for for for 1 2 3 4 outlet outlets outlets outlets Front cover, gas outlet, AGA, Ø = 75 mm for for for for for for for for 1 outlet, anodized 1 outlet, colour code: 2 outllets, anodized 2, colour code: 3, outlets, anodized 3, colour code: 4 outlets, anodized 4 outlets, colour code: Front cover, gas outlet, Greggersen, Ø = 42 mm for for for for for for for for 1 1 2 2 3 3 4 4 outlet, anodized outlet, colour code: outlets , anodized outlets, colour code: outlets, anodized outlets, colour code: outlets, anodized outlets, colour code: Front cover, gas outlet, Dräger, Ø = 60 mm for for for for for for for for 1 1 2 2 3 3 4 4 outlet, anodized outlet, colour code: outlets, anodized outlets, colour code: outlets, anodized outlets, colour code: outlets, anodized outlets, colour code: Specification/Order form 4. Gas (cont.) Art. No. T(p 45) 6100 6100 6100 6100 6100 6100 6100 6100 4. Gas (cont.) Type/Description Qty (pcs) Front cover ,gas outlet, MEDÆS, GEM 10, Ø = 52 mm 312 311 317 316 322 321 327 326 MWU-GU1, MWU-GU1, MWU-GU2, MWU-GU2, MWU-GU3, MWU-GU3, MWU-GU4, MWU-GU4, for for for for for for for for 1 1 2 2 3 3 4 4 outlet, anodized outlet, colour code: outlets, anodized outlets, colour code: outlets, anodized outlets, colour code: outlets, anodized outlets, colour code: Front cover, Wall bracket, Stop ends (p 46) Front cover, gas pipe 6100 002 6100 001 MWU-GP, anodized MWU-GP, colour code: Art. No. T- Type/Description (p 47) Gas accessories 6100 810 6100 811 6100 812 MWU-GA 4 x Ø 8 mm MWU-GA 2 x 2 Ø 10 mm MWU-GA 2 x 2 Ø 12 mm 5590 500 TTI-JB 5590 505 TTI-JK300 Mounting plate with pipe clamps Earthing clamp Earth wire 5. Accessory rail Art. No. T- Type/Description (p 48) Accessory rail 6100 820 6100 830 6100 825 MWU-AP, rail, anodized MWU-AB, bracket, anodized MWU-AA, cap, grey MWU-GB, untreated 6100 051 6100 056 MWU-GE, left, colour code: MWU-GE, right, colour code: Stop ends* Stop ends with outlet for TRL gas pipe cover* 6100 840 MWU-AP, rail, untreated 6100 6100 6100 6100 6100 6100 071 076 061 066 081 086 MWU-GE, MWU-GE, MWU-GE, MWU-GE, MWU-GE, MWU-GE, 5321 5321 5321 5321 100 120 122 210 left TRL5630, colour code: right TRL5630, colour code: left TRL5656, colour code: right TRL5656, colour code: left TRL7640, colour code: right TRL7640, colour code: 6100 845 MWU-AS, untreated/grey Accessory rail, DIN type DIN-rail shelf 6. Tools Art. No. T- Type/Description Cover for gas pipe (p 49) TRL-D5630, TRL-D5656, TRL-D5656, TRL-D7640, 5900 055 5900 056 5900 040 Tools ISV-KS, Electrical cutting saw Blade, for Electrical cutting saw ISV-SG217, Radial arm cutting saw with work-table 5900 5900 5900 5900 5900 ISV-G400, Mitre box ISV-GS550, replacement blade for ISV-G400 ISV-HS, Plunge tool INKA-JT, Jig template ISV, Front cover opener anodized anodized colour code: anodized Base clamp (with ties) 5322 010 5322 020 5322 050 TRL-H56 TRL-H76 TRL-T 5322 122 TRL-ES5656, grey Qty (pcs) Accessory rail, Scandinavian type Wall bracket, gas pipe front cover 6100 090 Qty (pcs) 000 001 020 130 900 Qty (pcs) Stop end (for terminating TRL gas pipe covers) * If anodized gas profile is chosen, stop ends in colour code L23 (RAL 9007) are recommended. Project: .................................................................................................................................................................... Sub-specification: ...................................................................................................................................................... Company: .................................................................................................................................................................... Reference: .................................................................................................................................................................... Address: ...................................................................................................................................................................... Phone: .......................................................................................................................................................................... Telefax: ........................................................................................................................................................................ Fax or mail the Specification/Order form to Thorsman International or to your local Thorsman representative. THORSMAN INTERNATIONAL Thorsman & Co AB, Box 1010, SE-611 29 Nyköping, Sweden Telephone +46-155 26 50 00. Telefax +46-155 26 63 66 E-mail: mail.int@tcn.thorsman.se Web Site: www.thorsman.com Lexel in Brief The Lexel Group is one of Europe’s leading suppliers of installation solutions for power, telecom, datacom and control applications with special focus on 'smart buildings', i.e. buildings equipped with technology providing increased levels of comfort, economy and security. The Lexel product programme includes everything from switches, outlets, installation materials and installation systems for cable management to communication networks, security systems, and systems and software for control of building functions. Respect for the environment is an integral part of all Lexel activities. One example is the development and certification of environmental management systems complying with ISO 14000. In the field of polymers Lexel is working to eliminate the use of heavy metals and ozone-depleting substances. The Lexel Group is owned by Schneider Electric of France and has its operational head office in Stockholm, Sweden. The Group has a turnover of over EUR 650 million and employs some 6000 people. Lexel is a market leader in the Nordic countries, Poland and the Baltic States, but is also strongly placed in Russia and a number of Central European countries. Sales are effected through subsidiaries in 18 countries and distributors in more than 30. Europe Austria, Belgium, Bosnia and Herzegovina, Bulgaria, Belarus, Croatia, Cyprus, France, Greece, Hungary, Iceland, Italy, Macedonia, Portugal, Romania, Slovenia, Spain, Switzerland, Ukraine, Yugoslavia. Other markets Argentina, Australia, Bahrain, Hong Kong, Israel, Japan, Jordan, Kazakhstan, Kuwait, Lebanon, Malaysia, Mexico, Oman, Qatar, Saudi Arabia, Singapore, Turkey, U.A.E., U.S.A. THORSMAN INTERNATIONAL Electricity the professional way Thorsman & Co AB • Box 1010 • SE-611 29 Nyköping, Sweden • Telephone +46-155-26 50 00 • Telefax +46-155-26 63 66 • www.thorsman.com MC1823/INT/GB/0112. © THORSMAN & CO AB. Österbergs & Sörmlandstryck, 23550 International representation, brand Thorsman Thorsman International is the marketing organization responsible for marketing in all non-subsidiary markets by working with a large network of agents and distributors throughout the world.