E SERIES ENCLOSURES

DIMENSIONS:

GL840E-2936 • 84.00"H x 29.00"W x 36.00"D

GL840E-2932 • 84.00"H x 29.00"W x 32.00"D

GL840E-2436 • 84.00"H x 24.00"W x 36.00"D

GL840E-2432 •

RACK SPACES:

84.00"H x 24.00"W x 32.00"D

All Enclosures are 44 RMU 19" EIA 310-D Compliant

WEIGHT CAPACITY:

All Enclosures are 1500 lbs. on Levelers, bolted to floor, or on Heavy Duty Casters

DIMENSIONS:

GL720E-2936 • 72.00"H x 29.00"W x 36.00"D

GL720E-2932 • 72.00"H x 29.00"W x 32.00"D

GL720E-2436 • 72.00"H x 24.00"W x 36.00"D

GL720E-2432 •

RACK SPACES:

72.00"H x 24.00"W x 32.00"D

All Enclosures are 37 RMU 19" EIA 310-D Compliant

WEIGHT CAPACITY:

All Enclosures are 1500 lbs. on Levelers, bolted to floor, or on Heavy Duty Casters

E Series Enclosures are designed specifically for easy mounting and protection of telecommunications equipment, computer hardware, and other 19” EIA rack mount equipment, whether in a small “computer room” or a large scale data center.

CONSTRUCTION

With fully welded steel construction, the E Series frame is formed five times for additional strength.

Each rail is formed three times creating a channel which will not bend or warp when heavy equipment is mounted. Few enclosures in the industry are constructed from such a durable design.

AIRFLOW

The ability to facilitate air flow within the enclosure is a key attribute of the E Series. Field reversible mesh or mesh contour doors allow conditioned air in and exhaust air out of the enclosure. (The mesh contour door also accepts fan mounting.) Great Lakes offers three different fan tops to exhaust hot air from the top of the enclosure and fan trays (with varying amounts of CFM) which can be mounted in the bottom to circulate extra cold air in support of any rack mounted equipment.

CABLE ACCESS & CABLE MANAGEMENT

Cable access provisions are integrated into the bottom of every enclosure frame and are available on removable top panels. These provisions allow data or power cables to be routed overhead or from a raised floor. Horseshoe knockouts in the removable top panels allow equipment to be added to the enclosure (or for the interchanging of top panels) without interfering with cable bundles.

In addition to cable access, the E Series features multiple cable management solutions. Vertical and horizontal tie down slots along the length of the rails create an integrated cable management system.

Optional lacing bar kits aid in routing cable up and down the enclosure, or from the front to the rear.

ACCESSORIES

Great Lakes’ portfolio of accessories allows E Series Enclosures to be customized, based on application.

• Six different door handles are available, depending on the degree of security desired.

• Grounding studs and kits help ground enclosures to the facility; copper bus bars help ground

equipment mounted in the enclosure.

• Networking holes and a tool-less ganging kit allow rows of enclosures to be easily aligned

• A wide variety of sliding, stationary and specialty shelving are available to accommodate

equipment of varying weights and dimensions.

To learn more about these accessories which are compatible with the E Series Enclosure, please visit us on the web at www.werackyourworld.com. Enclosures and popular accessories are listed together so there is no guess work! DIMENSIONS:

GL600E-2432 • 60.00"H x 24.00"W x 32.00"D

GL480E-2432 • 48.00"H x 24.00"W x 32.00"D

GL300E-2432 • 30.00"H x 24.00"W x 32.00"D

RACK SPACES:

GL600E-2432 • 31 RMU • 19" EIA 310-D Compliant

GL480E-2432 • 24 RMU • 19" EIA 310-D Compliant

GL300E-2432 • 13 RMU

WEIGHT CAPACITY:

• 19" EIA 310-D Compliant

GL600E-2432 • 600 lbs.

GL480E-2432 • 600 lbs.

GL300E-2432 • 300 lbs.

Corporate Headquarters

P.O. Box 551 • Edinboro, PA 16412 • 1-866-TRY-GLCC • (1-866-879-4522)

Phone: 814.734.7303 • Fax: 814.734.3907 • glcc@greatcabinets.com

Western Distribution • 535 East Glendale Avenue • Sparks, NV 89431 • Phone: 775.829.9913 • Fax: 775.829.9926

Great Lakes International • Aerbridge House • Dunshaughlin Business Park • Dunshaughlin Co. Meath • Ireland

Phone: 011 3531 8258777 • Fax: 011 3531 8258778

E

E SERIES ENCLOSURES

4

5

6

7

1

3

2

1

2

8

3

12

11

10

4

9

5 6

7 8 9 10 11 12

E Series Enclosures range from 13 RMU to 44 RMU, ideal for applications in a small office/home office, or a large data center. Standard features on each enclosure as well as optional accessories address cooling, power, cable management, and overall convenience.

• 29"W enclosures are designed for networking, while 24"W enclosures are ideal for server applications

• 19" EIA 310-D compliant rails have infinite front to rear adjustability; rails are folded three times to produce a channel effect, creating a more rigid rail

• Split rear doors (either mesh or fan) aid in enclosure ventilation while also minimizing the amount of floor space needed to maintain the rear of equipment

The featured enclosure, GL840E-2936, demonstrates these standard and optional features.

1.

RMU markings on all rails allow quick installation of equipment; Great Lakes’ cable management posts and cinch straps mount to “extra” holes along rails, not rack spaces

2.

Vertical lacing bars move independently from enclosure rails to route cable up and down where needed; horizontal lacing bars route cable from the front to rear

3.

Locking swing handles come standard, but additional handles offer varying degrees of security

4.

Mesh doors feature a 68% open area, maximizing air flow into the enclosure

5.

Choice of solid, perforated, and fan tops; these tops feature horseshoe knockouts that allow interchanging of top panels without interfering with cables

6. All side panels are locking and easy lift-off; gasketing along the enclosure frame creates a close fit between the frame and panel

7. #12 GA rails are formed three times for strength and support cable management with round cable pass through holes as well as vertical and horizontal tie down slots

8.

Three removable hinges allow doors to be easily removed and reversed, while creating 180 o open swing

9.

PDU1 mounting brackets allow the vertical mounting of any 1 RMU equipment (such as power strips) without occupying any RMU space within the enclosure

10.

Casters and levelers can be installed together, making moving and placing the enclosure quick; anti-tip legs add extra safety as the enclosure becomes more populated

11.

Grounding studs on the top and bottom of the enclosure are standard; optional copper bus bars and grounding kits easily install to prevent equipment damage

12. Brush grommet bottom panels allow cable pass through while maintaining raised floor air pressure