Aegis Catalogue 1 providing intelligent solutions Why Aegis ? • Cost effective •Safe • Maintenance free • Simple operation • Easy to install • Climate independent • Automation ready 2 Aegis Catalogue Index 1. Introduction to Lucy Switchgear_________________________________________________________________ 4 2. Product Panorama: Lucy Medium Voltage and High Voltage range___________________ 5 3. Introduction to Aegis________________________________________________________________________________ 6 4. Installation and operating conditions__________________________________________________________ 7 5. Safety features________________________________________________________________________________________ 8 6. Application examples_______________________________________________________________________________ 9 7. Aegis range presentation________________________________________________________________________ 10 8. Available configuration___________________________________________________________________________ 10 9.Standards_____________________________________________________________________________________________ 10 10. Product characteristics____________________________________________________________________________ 11 a.General________________________________________________________________________________________________ 11 i. Product presentation ii. User interface and interlocking mechanism b. L: LBS Load Break Switch____________________________________________________________________________ 12 i. Standard features ii. Optional features, factory fitted iii. Optional features also available as retrofit c. Circuit Breaker; T or V modules______________________________________________________________________ 13 i. Standard features ii. Optional features, factory fitted iii. Optional features also available as retrofit d. Circuit Breaker protection___________________________________________________________________________ 14 i.TLF ii. Protection Relays iii. Protection CT (Current transformers) for TLF and Relays e. Options and Accessories_____________________________________________________________________________ 17 i. Secondary injection ii. Actuators (motorised) iii. Cable compartment iv. Shunt trip coils v. Earth Fault Indicators (EFI) 11. Switchgear Automation__________________________________________________________________________ 18 12. Cable bushings and cable terminations______________________________________________________ 19 13. Technical data sheet_______________________________________________________________________________ 20 14.Dimensions___________________________________________________________________________________________ 21 15. Order form____________________________________________________________________________________________ 22 To find out more about us, visit: www.lucyswitchgear.com 3 1. Introduction to Lucy Switchgear Lucy Switchgear is a global leader in switching, protection and automation solutions for electrical distribution systems, with over 100 years’ industry experience. Today the company is a specialist in secondary power distribution, engineering high-performance medium voltage switchgear for utility, industrial and commercial applications, overhead line equipment and providing retrofit and automation solutions to customers internationally. Engineering excellence, based on a long tradition of expertise, coupled with state of the art technology to meet customers’ stringent specifications, make Lucy Switchgear one of the few companies that can offer truly bespoke solutions. We have the capability to manufacture units for any location, climate or situation and offers a complete product portfolio, with a wide scope of services and dedicated after sales support throughout the product lifecycle. A specialist UK research and development facility, with a continuous programme of R&D, ensures that Lucy Switchgear’s products are always at the cutting edge, designed to anticipate the evolving technical and market demands of our customers. And our multi-million pound, purpose built, state of the art UK manufacturing facility provides complete control over production. Lucy Switchgear is a truly international company with offices in China, Dubai, Malaysia and South Africa; manufacturing facilities in the United Arab Emirates, Saudi Arabia and India; and an established global network of industrial partners and contractors operating in over 50 countries worldwide. Ring Main Unit range evolution TRIDENT SCIMITAR SABRE AEGIS 1965 4 1970 1975 1980 1985 1990 1995 2000 2005 2010 2015 2. Product Panorama: Lucy Medium Voltage and High Voltage range Range Name Trident Type Rated voltage (up to) Scimitar Sabre Aegis Rapier GX Ring Main Unit Rapier AX Rapier DSB Switch disconnector 17.5kV24kV24kV38kV36kV145kV 15.5kV Mode of fault current Fuse Fuse Vacuum Vacuum--interruption Insulation medium Oil SF6 Air Air Rated current 630A 800A 2500A (up to) Mounting Ground / Transformer Ground Installation Pole Pole Structure Indoor / Outdoor Outdoor Operation Local / Remote 5 3. Introduction to Aegis Aegis is a new generation of Ring Main Units mainly designed for secondary distribution networks up to 24kV. This range is available in indoor and outdoor formats to suit various application needs. All the live parts and switching functions are insulated with SF6 gas and sealed in a stainless steel tank ensuring a high level of reliability, personnel safety and virtually maintenance free operation. The structural tank welding is performed by a robotic welding process ensuring high reliability with a product life expectancy of more than 30 years. The housing is fully treated using zinc coated steel and electro statically applied, oven cured paint to resist degradation from pollution and harsh climatic conditions. The transformer protection is by vacuum Circuit Breaker. On request, the units can be supplied with integrated automation for remote monitoring and control functions. Characteristics: • 12kV, 17.5kV and 24kV ratings • Non extensible range with 3 and 4 switching functions in a single tank • Integrated cable testing facility on front face eliminating the need for cable disconnection • Suitable for indoor and outdoor applications • Hermetically sealed stainless steel tank insensitive to environment • Various protection options (TLF, relays) to suit customer needs • Intuitive single line mimic diagram for simple and safe operation • Low roof height designed for kiosks and mini substations • Vacuum Circuit Breaker enclosed in an SF6 insulated tank for extra protection against corrosion and pollution • Easy integration with SCADA network for remote operation and control • Provision for motor actuators for remote operation and control 6 • Standard RAL7032 paint finish with other colours available on request 4. Installation and operating conditions IP54 IP41 Outdoor Metal Clad Non Extensible units only i. Indoor and outdoor type units Indoor Extensible and Non Extensible Temperature De-rating Curves ii. Ambient temperature for operation without derating: 40°C (for higher temperature applications please refer to temperature derating curve below) iv. Maximum altitude for operation without derating: 1000m (above sea level)* v. Insulation medium: SF6 Gas vi. Rated pressure at +20°C: 0.03 MPa vii.Interruption medium: vacuum * For higher altitude applications please contact local Lucy Switchgear sales office. 650 Rated Current (Amps) iii. Average value over 24 hours max: 40°C 630A at 40°C 700 600 550 500 450 400 350 300 40 45 50 55 60 65 Ambient Temperature ° C 7 5. Safety features a)Operation mechanism e)Cable compartment The mechanism consists of one operating shaft and one selector. The operating shaft is used for switching ON / OFF (Mains or Earth) and the selector is used for selection of the Mains or Earth positions. It is impossible to simultaneously close the Load Break Switch or Circuit Breaker and the Earth switch. The cable compartments are located at the front of the units with horizontal mounted DIN 400 type C bushings for ease of cable connection. Vacuum Circuit Breaker function has factory mounted protection CT (current transformers) on the cable bushings for ease of installation and to avoid any potential damage to CT during transit and connections. The mechanism incorporates mechanical interlocks and padlocking facilities to improve operator safety. For enhanced operator safety, the cable compartments are earthed and fully interlocked allowing access to the operator only if the function is in Earth ON position. There is an option of supplying these cable compartments with Internal Arc rating as per IEC standards. b)Anti reflex mechanism: Earth bar in cable compartment A fully rated copper earth bar is mounted inside the cable compartment. This earth bar is used to connect the screened cable connectors through M12 size bolts. The bar runs through the width of the unit and protrudes 125mm to the rear of the cable compartment for connection to the main earthing system. For additional safety it is not possible to remove it while unit is live.  Ensures a time delay between switching operations to allow sufficient time for the main breaker to trip and clear a fault. c) Internal Arc withstand Aegis SF6 Gas insulated stainless steel tanks are fully internal arc rated and this feature is also available on the cable compartment (optional) to ensure maximum operator safety in the event of internal faults. As standard, all the tanks are rated for AFL (operator safety from the front and side of the unit) and there is an option to request for AFLR (front, side and back of the unit). For more details on IAC ratings, please refer to the technical data sheet on page 20. d)Earth and test facility The cable earth and test facility is an optional feature on the Load Break Switch and the Circuit Breaker. It is located at the front of the unit for ease of access. It is used for testing cable insulation and to locate faults in the circuit without the need to remove the main cables from the cable compartment, which improves the operator safety. The cable test access cover is fully interlocked and cannot be opened until the Load Break Switch or Circuit Breaker Switch is in Earth ON position. The test bushings are earthed with a star bar which has to be removed for cable tests. f)VPIS VPIS (Voltage Presence Indication System) is an optional feature in the Aegis range. It is used for checking the presence of voltages in the cables. The VPIS gets a voltage signal through the voltage divider built into the cable bushings. They can also be fitted with neon lights and momentary latching push buttons to show voltage presence without needing external testing probes. Two types of voltage presence indication device are offered: • Pfisterer sockets • Neon indicators with push-to-test buttons and phase comparator sockets Pfisterer sockets 8 Neon indicator with push-to-test buttons 6. Application examples The key areas of application are: a)Energy i. Generation: wind power, solar power ii.Distribution: compact substations b) Infrastructure: tunnels, airports, ports, underground railway stations c) Commercial buildings: hospitals, shopping centres, hotels, office buildings, data centres d) Industries: water and waste water, mining, minerals, automotive, iron and steel, paper and pulp, cement and petroleum 9 7. Aegis range presentation The Aegis range has 3 and 4 functions insulated by SF6 gas in a single hermetically sealed stainless steel tank. This solution is available in indoor and outdoor versions and is perfectly suitable for integration into compact substations to form standard Ring Main secondary networks with transformer protection. Switching functions: • L; LBS (Load Break Switch) 400A and 630A Circuit Breaker functions • T: Vacuum Circuit Breaker 250/400A • V: Vacuum Circuit Breaker 630A 8. Available configuration: The configuration of switchgear is very flexible; all L,T and V functions are available in any combination either 3 ways and 4 ways Non Extensible ranges. Non extensible (compact range) Function positions in unit Types of functions 1st2nd 3rd 4th L LLL T TTT V VVV 3 way units 4 way units 9.Standards International Standards IEC 62271-1 IEC 62271-100 IEC 62271-102 IEC 62271-103 IEC 62271-200 10 10.Product characteristics a) General i. Product presentation 1 EFI 2 Pressure indicator 3 Marshalling Box 4 Optional VPIS 5 Earth and Test Facility 6 Protection Relay 7 'Push To Trip' Button 8 Circuit Breaker Indication 9 Interlocked Cable Box Cover 1 3 2 5 4 6 7 8 10 14 13 11 12 10 Disconnector Indication 9 11 Cable Test and Cable Box Interlock 15 12 Disconnector Operation Collar 13 Operation Collar 14 Switch Indication 15 Operating Handle ii. User interface and interlocking mechanism Safety interlocking Each LBS and VCB module has safety interlocked access via a rotary knob on the fascia to enable access to the cable connection compartment and also the cable test access panel (if specified as an option) located on the fascia. Operating handle access shafts have the facility for individual padlocks. Load Break Switch Position Load Break Switch ON OFF OFF Earth ON Interlock status Selector Main Main Earth Earth Cable compartment interlock Locked Locked Locked Unlocked Earth & Test interlock (if fitted) Locked Locked Locked Unlocked Circuit Breaker Position Interlock status Circuit Breaker Selector ON OFF (Tripped) OFF (Reset) Earth ON Earth ON OFF (Tripped) Main Main Earth Earth Earth Earth Cable compartment interlock Locked Locked Locked Unlocked Locked Locked Earth & Test interlock (if fitted) Locked Locked Locked Unlocked Locked Locked 11 b) Switching functions L: LBS Load Break Switch i. Standard features ii. Optional features, factory fitted • Three functions (ON, OFF & Earth), two position spring loaded mechanism, independent manual operation • Internal arc rating of cable compartment for additional safety • Single mechanism with two independent operating shafts, one for switch ON / OFF position and another for selecting in Mains and Earth operation • Remote low gas pressure alarm,1N/O (only one per tank) • Interlocked selector, locked from operation when switch is in ON position • Single line intuitive mimic diagram with clear indication to show the status of switch (ON, OFF or Earth positions) • Gas pressure indicator with Red and Green sectors to indicate minimum permissible pressure for safe operation (only one per tank) • Horizontal cable terminations in front with DIN400 type C bushings • Fully interlocked cable compartment allowing entry only if function is in Earth ON position • Padlock facility (8.5mm diameter hole) for all the operating positions 12 • VPIS – Voltage Presence Indication System • Remote switch position indicator (1N/O,1N/C and 2N/O,2NC) • Fully interlocked cable earth and test (E&T) facility without removing main cable connections • Short circuit and Earth Fault Current Indicators (EFI) • Wiring for motorisation iii.Optional features also available as retrofit • Motor operation for Load Break Switch (only if unit is pre wired for motorisation) • Wide range of cable clamps, and glands to accommodate 1 and 3 core cables (refer to cable compartment section on page 17 for further information) c) Circuit Breaker; T or V modules T module 250A and 400A rated vacuum circuit breakers for transformer protection V module: 630A rated vacuum circuit breaker for transformer / downstream network protection i. Standard features • Three functions (ON, OFF & Earth), two position spring loaded mechanism, independent manual operation • Single mechanism with two independent operating shafts, one for circuit breaker ON/OFF position and another for selecting disconnector in Mains or Earth (isolation) • Interlocked disconnector selector, locked from operation when circuit breaker is in ON position • Mechanical push-to-trip button for local operation • Trip coil for receiving tripping signal from relay or TLF devices • Protection function TLF or relay (customer specific) • Single line intuitive mimic diagram with clear indication to show the status of switch (ON, OFF or Earth positions) • Gas pressure indicator with Red and Green sectors to indicate minimum permissible pressure for safe operation (only one per tank) • Horizontal cable terminations at front of unit with DIN 400 C type bushings • Protection CT (current transformers) mounted on cable bushings (customer specific) ii. Optional features, factory fitted • Internal arc rating of cable compartment for additional safety • Remote low gas pressure alarm,1N/O (only one per tank) • VPIS – Voltage Presence Indication System • Remote circuit breaker position indicator (1N/O,1N/C and 2N/O,2NC) • Fully interlocked cable test facility without the need to remove main cable connections (refer to cable test facility for further information) • Self-powered relay for protection (customer specific) • TLF (Time Limit Fuses) for alternative protection • Wide range of Current transformers for TLF and Relay protection • Shunt trip coils for external tripping • Wiring for motorisation iii.Optional features also available as retrofit • Motor operation for CB (only if unit is pre wired for motorisation) • Wide range of cable clamps, and glands to accommodate 1 and 3 core cables (refer to cable compartment section on page 17 for further information) • Fully interlocked cable compartment allowing entry only if function is in Earth ON position • Padlock facility (8.5mm diameter hole) for all the operating positions 13 d) Circuit breaker protection Two types of protection devices are offered to protect the circuit breaker; i. TLF : Time Limit Fuses ii. Protection Relays i.TLF When utilised in conjunction with circuit breaker type Ring Main Units, Time Limit Fuses (TLF) are a cost effective method of providing fault protection for overcurrent and earth faults (optional) to a transformer of 2000kVA or less. It is a recognised method of protection and was developed to comply with EA 41-26 (now superseded by ENA TS 41-36) with fuse links in accordance with ENA TS 12-6. It should be noted that the TLF protection system is not a device for limiting overload levels of individual transformers. It should be used for fault protection only. The TLF system provides protection for overcurrent and earth faults between the MV Circuit Breaker and the LV protection device. The selected TLF rating should be such that it allows for discrimination between the MV & LV devices. This will ensure that the Circuit Breaker does not open for faults beyond the LV distributor protection device. When fitted with TLF, the Ring Main Unit can also be configured to enable tripping of the Circuit Breaker from remote devices (Bukholtz, LV CB etc). Fuse dimensions: Length 57mm x Diameter 13mm RMU Lucy Switchgear customers in Europe, the Middle East, Africa and Asia are currently using TLF protection system within their distribution networks. TLF Transformer LV distribution Panel 14 Recommended TLF settings Transformer ratings (kVA) 200 315 500 Rated Voltage (kV) CT Ratio 50/5 Earth fault setting = 25A (instantaneous trip) CT Ratio 100/5 Earth fault setting = 30A (instantaneous trip) 800 1000 1250 1600 2000 12.5A 12.5A 5A 15A 15A 5A 7.5A TLF Fuse Rating (A) 3.3 6.6 11 13.8 24 10A 5A 3A 3A 3.3 6.6 11 13.8 24 5A 10A 5A 5A 10A 5A 15A 10A 10A 3A 15A 15A 5A 7.5A 15A 7.5A 5A 5A 12.5A 7.5A 7.5A 15A 10A 10A Advantage of Vacuum Circuit Breaker with TLF over HV fuses Feature VCB with TLF Fuse Switch Overall cost of units Similar Approximate fuse replacement cost $5$50 Maximum rating of transformer, can be protected 2MVA* 1MVA Maximum rated normal current 630A200A Physical size of fuses SmallLarge Possibility of some pollution while changing fuses causing PD and flash over issues NoYes Fuse location inside the unit LV side HV side Range of fuses required for different rated transformers Very small with multi ratio CT Large *No issues with transfer current switching to IEC 62271-105, which minimizes the MVA rating Advantage of Vacuum Circuit Breaker with TLF over Protection Relays Feature Installation cost of function Auxiliary power source for operation Delay in activation of trip function due to capacitor charging time lag Employee training on setting tripping curves Additional training on different manufacturer setting up procedure Maintenance and repair cost Operating temperature limitations Upstream and Downstream discrimination protection of circuit Over current and Earth Fault protection VCB with TLF Protection Relay LowHigh Not required As required No delayDelay Not requiredRequired Not requiredRequired LowHigh None Up to 70 °C YesYes YesYes 15 ii. Protection Relays ManufacturerWoodward Range WIP1 Functions Phase overcurrent Short circuit protection Number of overcurrent elements Earth overcurrent Number of Earth overcurrent elements The Aegis range can be fitted with self-powered relays for protecting the transformer or downstream network from fault currents by tripping the Circuit Breaker. These relays incorporate many advanced features and have a variety of settings to provide discrimination protection in networks. The self-powered feature eliminates reliance on external power sources and increases the performance and reliability of the protection function. To the right are the technical characteristics of the Woodward WIP1 relay, offered as a standard on the Aegis range (if ordered with relay function). Other manufacturers’ relays can also be incorporated into the units on request. Characteristics Display (measuring values and parameters) Setting via buttons Standard CT LED pickup LED trip indicator Flag indication output Fault memory Clock Password protection Electro impulse and relay contact output Number of output relays Input remote tripping Interface RS 485 interface with pro open data protocol RS-485 interface with Modbus protocol Additional power supply Key • Standard • • 2 • 2 • • 1A • • • • • • • 3 C/O • O O O O O Option Other manufacturers’ relays are also available on request, please contact our local sales office for more information. iii.Protection CT (Current transformers) for TLF and Relays The protection CT are used in conjunction with Relays or TLF protection to protect a wide (kVA) range of distribution transformers. A comprehensive range of CT (current transformers) is available to suit varied application requirements. Dual Ratio CT 100/50/Dual Ratio CT 200:100/Triple Ratio CT 150:100:50/An extensive range of additional CT’s are available on request, please contact our local sales office for more information. 16 e) Options and Accessories i. Secondary injection iv.Shunt trip coils Secondary injection is used to test the relays or TLF operation without switching on the high voltage supply to the unit. A low voltage is applied to the secondary side of the CT connection (located in terminal box) to test the operation of the protection devices at the time of commissioning and routine tests. Shunt trips are magnetic coils and are used to trip circuit breakers through local push buttons, RTUs or additional transformer protection devices. Shunt trips are available in the following voltages; ii. Actuators (motorised) Aegis units are fitted with 24V DC motors, which can be powered from the Gemini Remote Terminal Unit (RTU) 24V DC battery in the event of mains AC supply failure. • DC voltage: 12V, 24V, 48V and 110V • AC voltages: 110V, 240V • Multiple voltage range: 24VDC – 240VAC v. Earth Fault Indicators (EFI) iii.Cable compartment All the cable clamps, glands and cable compartment sealing devices are available as retrofit options. Below is the list of clamps available in metal (steel) and plastics. • Single 3 core cable • 3 single core cables Earth Fault Indicators (EFI) are used for rapid location and isolation of faults on medium voltage networks in open loop ring main networks. When the unit detects asymmetrical currents greater than 50A in the 3 phase cable an earth fault is indicated by means of a flashing LED or mechanical flag. Below is the list of EFIs available for the Aegis range. An extensive range of additional cable compartment clamps and sealing devices are available on request, please contact our local sales office for more information. Single 3 core cable Manufacturer:Suparule Model: Sensorform 3 single core cable BLZ-50BFZ-50MFZ-50MLZ-50CFZ-50CLZ-50 Features Power source3.6V lithium ½ AA 110-240V a.c. CT on current 850mAH battery carrying phase Voltage range 1 – 38kV Trip current 50A Primary indication LEDMech-flag (RED) LEDMech-flag (RED) LED Flashing duration >1000 hrs-- 10 hrs- 10 hrs Minimum fault duration 2.5 cycles Manual reset Push button Automatic timer reset4 or 8 hrs selectable 10 secs after mains restore Manual trip test Push button Operating temperature -40°C to +80°C Operating humidity 0-100% RH Ingress protection IP65 Current sensor diameter: CT100: 100mm •••••• CT150: 150mm OOOOOO CT300: 300mm OOOOOO Remote flashing LED indicator OOOOOO Auxiliary relay, 1N/O latching OOOOOO Key • Standard O Option Other manufacturers’ EFIs are also available on request, please contact our local sales office for more information. 17 11.Switchgear Automation The Gemini RTU is an advanced, highly flexible and ultra-efficient solution for remote operation and control of electrical distribution networks. Enclosed in a stainless steel casing for maximum protection, the Gemini RTU is designed to operate in the most demanding environments. The key features of the Gemini range are: • Embedded auto change over and auto sectionalising functions • Control and monitoring of up to 4 motorised functions (switches or circuit breakers) • Inbuilt Earth and Fault Passage Indicators • Advanced monitoring of current, voltage, battery condition, temperature compensation, switching status, automatic cooling system, gas pressure etc • Flexible communication through radio, RS232, RS485, packet data network, GSM, GPRS, PSTN, Bluetooth, Ethernet TCP/IP, optical fibre and SMS messaging • Advanced battery back to operate under mains AC input failure • Fully tested to ENATS (Energy Network Association Technical Standards), EMC and environmental standards In addition to the features opposite, remotely monitored and controlled switchgear provides significant benefits to customers such as: • Reduced time in diagnosing system anomalies as well as locating and isolating faulty sections of network • Faster response time and quick network reconfiguration • Optimisation of asset management through the implementation of customised automation schemes • Reduced operational cost associated with routine network switching • Increased operator safety Gemini RTU Specification General Enclosure Stainless steel Degree of Protection IP54 Operating Temperature -25 to 60°C Relative Humidity Up to 95% Method of Mounting Floor, wall, pole or RMU switchgear Dimensions H 600mm, W 400mm, D 210mm RTU Hardware Processor Module ARM9 Microprocessor Power Supply 110 / 230V AC supply – over and under-voltage protection Battery Type 2 x 12V DC, sealed lead acid or high temperature NiMH Battery Charger Temperature compensated, fully protected Control Electronics PIC based processor with expandable I2C bus Inner Enclosure Stainless steel Ventilation Microprocessor controlled, long life fan with baffle air intake filter Inputs / Outputs Digital Inputs 14 isolated digital inputs – expandable Digital Outputs 8 isolated digital outputs – expandable Analogue Inputs 3 CT analogue inputs as standard (DIs reduced to 11) Expansion I/O Module 3 AIs / 4 DIs; 7 DIs / 2 DOs Communications Communication Interfaces 3 RS-232 for Control (Ethernet option), Configuration and Programming plus one Expansion Bus Protocols DNP3, IEC 60870-5-101/104 and Modbus (others on request) Communication Media RS-232 / 485, UHF / VHF radio, Packet Data, GSM / GPRS / EDGE, PTSN, Leased or Twisted Pair Lines, Optical Fibre, Ethernet (TCP/IP) and Bluetooth Switchgear Interface Controls Membrane push-button for Open / Close operations in conjunction with Activate push-button up to four switching functions (standard 1, 2, 3 or 4 switch control formats) Selector control for Off, Local or Remote modes Indications RTU services such as DC / AC supplies, Dummy Control and Debug LEDs Switch status LEDs for Open / Closed positions Control Output LEDs (illuminates when active) Configurable LED indications Cables Plug-in, multi-core umbilicals to switchgear Software Configuration Windows-based software for configuration of: • Protocol parameters including device and I/O addresses • Parameters for the communications device • Parameters for digital, analogue and counter points • Automation sequences • Power saving routines • Battery tests 18 12. Cable bushings and cable terminations The bushings for each ring switch and circuit breakers are located at the front of the unit. All sets of bushings are type ‘C’ with in-line bolted connections M16 threaded in accordance with EN50181. The bushings are accessible by removing the interlocked cable compartment covers at the front of the unit. The maximum cable size that can be used is: • 300mm² 3 - core • 500mm² single - core. The following types of terminations can be used with the Aegis: Insulating Bushing Boot Heat Shrink Insulating Bushing Boot Profile 'C' Bolted Separable 19 13. Technical data sheet General Circuit Breaker V and T function Rated Voltage kV 1217.524 Rated normal current Rated frequency Hz 506050 Rated lightning Impulse withstand voltage V function A 630- - T function A 250250400 Directly earthed kV 95 95125 Rated active load breaking current A 630250400 Across disconnector kV 110110145 Rated short circuit breaking current kA 202120 Rated power frequency withstand voltage Rated short circuit making current kA 5054.650 Directly earthed kV 383850 Rated cable charging breaking current A 25 31.531.5 Across disconnector kV 454560 Rated short time withstand current Protection Main electrical circuit Tank with HV parts IPIP67 1 sec kA -21- LV control box IPIP41 3 sec kA 20-20 Front face + mechanism IPIP41 Earthing circuit Cable box IPIP41 1 sec kA -21- Mechanical impact protection IKIK07 3 sec kA 20-20 Internal arc rating Mechanical endurance class Freestanding kA 1 sec 21kA 1 Sec Circuit breaker M1 / 2000 Optional cable box kA 1 sec 21kA 1 Sec Earth switch M0 / 1000 AFL (gas chamber) Standard Electrical endurance class AFLR (gas chamber) Optional Circuit breaker E2/2000 Earth switch E1 SF6 gas Filled pressure Bar (G)0.40.40.5 Operating mechanism Minimum operating pressure Bar (G)0 00.3 Tripping time Annual leakage rate ≤0.01% per annum≥ Installation conditions °C Maximum altitude (without derating)* M1000 405555 Relative humidity (max) - over period of 24hrs (IEC 62271-1, sub-clause 2.1) 95% * For higher altitude applications please contact local Lucy Switchgear sales office. BusBars A 630400400 Rated short time withstand current 1 sec kA -21- 3 sec kA 20-20 Rated peak withstand current kA 5054.650 Load Break Switch: L function Rated normal current A 630400400 Rated active load breaking current A 630400400 Rated short circuit making current kA 5054.650 Rated cable charging breaking current A 101016 Rated short time withstand current: Main electrical circuit 1 sec kA -21- 3 sec kA 20-20 Earthing circuit 1 sec kA -21- 3 sec kA 20-20 Mechanical endurance class Load break switch M2 / 5000 M2 / 5000 M2 / 5000 Earth switch M0 / 1000 M0 / 1000 M0 / 1000 Electrical endurance class short circuit making Load break switch E3 / 5 E1 / 2 E1 / 2 Earth switch E3 / 5 E1 / 2 E1 / 2 Operating mechanism Local: Close / Open Hand Lever Remote: Close / Open Motor 20 > 80 > 80 > 80 Local: Close / OpenHand lever / Pushbutton Ambient air temperature (without derating) Rated normal current ms Operating sequence for mechanism 0-3min-CO-3min-CO Remote: Close / Open Motor / Coil 14.Dimensions 3 way 4 way 1235mm 1650mm Side View 50mm Dimension 'B' Dimension 'A' 905mm Cable termination height “B” (mm) (Distance between cable clamp and bushings) Reduced Standard Tall Overall height of Unit Without E&T facility “A” (mm) 450 1100 6001250 8101450 1: L function height is not affected with addition of E&T facility 2: For V & T functions with E&T facility add 150mm to overall height “A”of the unit 21 15. Aegis Order Form To use this form, please photocopy and return the completed form to your nearest Lucy Switchgear office (addresses can be found on the back cover) Name: Company: Address: Tel No: Fax No: Email: Order Number: Order quantity / number of units (please fill separate form for each type) IP rating: Installation conditions (choose any one)IP54 Metal clad outdoor IP41 Indoor Colour RAL7032 as standard (other colours are only available on request) Features common to all functions Voltage rating (choose any one) 12KV 17.5kV 24kV Low gas Pressure alarm 1N/O (tick if needed, only one per tank) Number of ways and functions needed at each position: FirstSecond ThirdFourth (e.g. 1 function) (e.g. 2 function) (e.g. 3 function) (e.g. 4 function) Starting from the left, write any one of L, V or T in each box depending upon the number of ways needed. Voltage Range Functions current ratings 12kV17.5kV24kv L 630A400A400A T 250A250A400A V 630A– – For example: L V T L Motor wiring (tick for each selected function, if needed) Motor for remote operation (tick for each selected function, if needed) Cable Earth & Test facility (E&T) (tick for each selected function, if needed) Cable bushings termination height (choose any one) 450 600 810 Cable box: Internal Arc proof VPIS (choose any one) Neon indicator with push to test button Pfisterer socket Auxiliary switches (choose any one) 1N/O, 1N/C 2N/O, 2N/C Cable compartment Cable clamp material (choose any one) Metal Plastic Cable entry type (choose any one) 3 single core cable Single 3 core cable Optional features applicable to L (Load Break Switch) function only Rated current (choose any one) 400 Amps (available for 17.5 and 24kV) 630 Amps (only available for 12kV) EFI (choose any one) BFZ-50 MFZ-50 MLZ-50 CFZ-50 CLZ-50 BLZ-50 Any other* Optional features applicable to V or T (Vacuum Circuit Breaker) function only Secondary injection (tick for each selected function, if needed) Protection device (choose any one) TLF (Time Limit Fuses) WIP1 Other* Protection (CT) current transformer for TLF or Relay (choose any one) Dual (Primary) Ratio CT 100:50/- Dual (Primary) Ratio CT 200:100/- Triple (Primary) Ratio CT 150:100:50/- Manual Push To Trip button (tick for each selected function, if needed) Shunt Trips (choose any one) 12V DC 24V DC 48V DC 110V DC 110V AC 240V AC Multiple voltage (24V DC - 240VDC) Note: The ring main units gas chamber are supplied with AFL (Front and sideways) rating. If you require units with AFLR (Front, side and rear) ratings please contact our local sales office. *Please fill the details in comment section below. Comments Disclaimer Lucy Switchgear has a policy of continuous research and development and accordingly reserves the right to change the design and specification of its products without prior notice. Lucy Switchgear worldwide offices Lucy Switchgear Ltd. Howland Road, Thame, Oxfordshire, OX9 3UJ, United Kingdom Tel: +44 1844 267 267 General Tel: +44 1844 267 222 Sales Fax: +44 1844 267 223 Email:salesuk@lucyswitchgear.com Lucy Switchgear Arabia Co. Ltd. Novotel Business Centre, P.O. Box 35340, Dammam 31488, Saudi Arabia Tel: +966 3 8147 910 Fax: +966 3 8147 914 Email:salessa@lucyswitchgear.com Lucy Asia Pacific Sdn Bhd L13A-03-03A, PJX-HM Shah Tower, No16A Jalan Persiaran Barat, 46050 Petaling Jaya, Selangor, Malaysia Tel: +603 74910700 Fax: +603 79316923 Email:salesmy@lucyswitchgear.com Lucy Middle East FZE PO Box 17335, Jebel Ali, Dubai, United Arab Emirates Tel: +97 148 129 999 Fax: +97 148 129 900 Email:salesme@lucyswitchgear.com Lucy Switchgear (South Africa) Unit 2, Cranberry Industrial Park, Cranberry Street Laser Park, Honeydew, 2170, South Africa Tel: +27 10 593 3034 Fax: +27 10 593 3035 Email:salesza@lucyswitchgear.com Lucy Electric (Beijing) Co. Ltd. 卢西电器(北京)有限公司 北京市朝阳区东三环北路霞光里 18号佳程广场A座1122室 邮编:100027 电话:+86 1059 231 176 传真:+86 1059 231 177 电子邮件: salescn@lucyswitchgear.com Postal Address: P.O. Box 1078, Honeydew, 2040 To find out more about us, visit: www.lucyswitchgear.com LSAEG0613