providing intelligent solutions
Why Aegis ?
• Cost effective
•Safe
• Maintenance free
• Simple operation
• Easy to install
• Climate independent
• Automation ready
2
Aegis Catalogue
Index
1.
Introduction to Lucy Switchgear_________________________________________________________________ 4
2.
Product Panorama: Lucy Medium Voltage and High Voltage range___________________ 5
3.
Introduction to Aegis________________________________________________________________________________ 6
4.
Installation and operating conditions__________________________________________________________ 7
5.
Safety features________________________________________________________________________________________ 8
6.
Application examples_______________________________________________________________________________ 9
7.
Aegis range presentation________________________________________________________________________ 10
8.
Available configuration___________________________________________________________________________ 10
9.Standards_____________________________________________________________________________________________ 10
10. Product characteristics____________________________________________________________________________ 11
a.General________________________________________________________________________________________________ 11
i. Product presentation
ii. User interface and interlocking mechanism
b.
L: LBS Load Break Switch____________________________________________________________________________ 12
i. Standard features
ii. Optional features, factory fitted
iii. Optional features also available as retrofit
c.
Circuit Breaker; T or V modules______________________________________________________________________ 13
i. Standard features
ii. Optional features, factory fitted
iii. Optional features also available as retrofit
d.
Circuit Breaker protection___________________________________________________________________________ 14
i.TLF
ii. Protection Relays
iii. Protection CT (Current transformers) for TLF and Relays
e.
Options and Accessories_____________________________________________________________________________ 17
i. Secondary injection
ii. Actuators (motorised)
iii. Cable compartment
iv. Shunt trip coils
v. Earth Fault Indicators (EFI)
11. Switchgear Automation__________________________________________________________________________ 18
12. Cable bushings and cable terminations______________________________________________________ 19
13. Technical data sheet_______________________________________________________________________________ 20
14.Dimensions___________________________________________________________________________________________ 21
15. Order form____________________________________________________________________________________________ 22
To find out more about us, visit:
www.lucyswitchgear.com
3
1. Introduction to
Lucy Switchgear
Lucy Switchgear is a global leader in
switching, protection and automation
solutions for electrical distribution
systems, with over 100 years’ industry
experience. Today the company is a
specialist in secondary power distribution,
engineering high-performance medium
voltage switchgear for utility, industrial
and commercial applications, overhead
line equipment and providing retrofit
and automation solutions to
customers internationally.
Engineering excellence, based on a long tradition of
expertise, coupled with state of the art technology to
meet customers’ stringent specifications, make Lucy
Switchgear one of the few companies that can offer truly
bespoke solutions. We have the capability to
manufacture units for any location, climate or situation
and offers a complete product portfolio, with a wide
scope of services and dedicated after sales support
throughout the product lifecycle.
A specialist UK research and development facility, with a
continuous programme of R&D, ensures that Lucy
Switchgear’s products are always at the cutting edge,
designed to anticipate the evolving technical and market
demands of our customers. And our multi-million pound,
purpose built, state of the art UK manufacturing facility
provides complete control over production.
Lucy Switchgear is a truly international company with
offices in China, Dubai, Malaysia and South Africa;
manufacturing facilities in the United Arab Emirates,
Saudi Arabia and India; and an established global
network of industrial partners and contractors operating
in over 50 countries worldwide.
Ring Main Unit
range evolution
TRIDENT
SCIMITAR
SABRE
AEGIS
1965
4
1970
1975
1980
1985
1990
1995
2000
2005
2010
2015
2. Product Panorama: Lucy Medium
Voltage and High Voltage range
Range Name
Trident Type
Rated voltage (up to)
Scimitar
Sabre
Aegis
Rapier GX
Ring Main Unit
Rapier AX Rapier DSB
Switch disconnector
17.5kV24kV24kV38kV36kV145kV
15.5kV
Mode of
fault current
Fuse
Fuse
Vacuum
Vacuum--interruption
Insulation
medium
Oil
SF6 Air
Air
Rated current
630A
800A
2500A
(up to)
Mounting
Ground / Transformer
Ground
Installation
Pole
Pole
Structure
Indoor / Outdoor
Outdoor
Operation
Local / Remote
5
3. Introduction to Aegis
Aegis is a new generation of Ring Main
Units mainly designed for secondary
distribution networks up to 24kV. This
range is available in indoor and outdoor
formats to suit various application needs.
All the live parts and switching functions
are insulated with SF6 gas and sealed in a
stainless steel tank ensuring a high level of
reliability, personnel safety and virtually
maintenance free operation.
The structural tank welding is performed by a robotic
welding process ensuring high reliability with a product
life expectancy of more than 30 years. The housing is
fully treated using zinc coated steel and electro statically
applied, oven cured paint to resist degradation from
pollution and harsh climatic conditions.
The transformer protection is by vacuum Circuit Breaker.
On request, the units can be supplied with integrated
automation for remote monitoring and control functions.
Characteristics:
• 12kV, 17.5kV and 24kV ratings
• Non extensible range with 3 and 4 switching functions in a single tank
• Integrated cable testing facility on front face eliminating the need for cable disconnection
• Suitable for indoor and outdoor applications
• Hermetically sealed stainless steel tank insensitive
to environment
• Various protection options (TLF, relays) to suit customer needs
• Intuitive single line mimic diagram for simple and
safe operation
• Low roof height designed for kiosks and
mini substations
• Vacuum Circuit Breaker enclosed in an SF6 insulated tank for extra protection against corrosion
and pollution
• Easy integration with SCADA network for remote operation and control
• Provision for motor actuators for remote operation and control
6
• Standard RAL7032 paint finish with other colours available on request
4. Installation and
operating conditions
IP54
IP41
Outdoor
Metal Clad
Non Extensible units only
i. Indoor and outdoor type units
Indoor
Extensible and
Non Extensible
Temperature De-rating Curves
ii. Ambient temperature for operation without derating:
40°C (for higher temperature applications please refer to temperature derating curve below)
iv. Maximum altitude for operation without derating: 1000m (above sea level)*
v. Insulation medium: SF6 Gas
vi. Rated pressure at +20°C: 0.03 MPa
vii.Interruption medium: vacuum
* For higher altitude applications please contact local Lucy Switchgear sales office.
650
Rated Current (Amps)
iii. Average value over 24 hours max: 40°C
630A at 40°C
700
600
550
500
450
400
350
300
40
45
50
55
60
65
Ambient Temperature ° C
7
5. Safety features
a)Operation mechanism
e)Cable compartment
The mechanism consists of one operating shaft and
one selector. The operating shaft is used for switching
ON / OFF (Mains or Earth) and the selector is used for
selection of the Mains or Earth positions. It is impossible
to simultaneously close the Load Break Switch or Circuit
Breaker and the
Earth switch.
The cable compartments are located at the front of
the units with horizontal mounted DIN 400 type C
bushings for ease of cable connection. Vacuum Circuit
Breaker function has factory mounted protection CT
(current transformers) on the cable bushings for ease
of installation and to avoid any potential damage to CT
during transit and connections.
The mechanism
incorporates mechanical
interlocks and padlocking
facilities to improve
operator safety.
For enhanced operator safety, the cable compartments
are earthed and fully interlocked allowing access to the
operator only if the function is in Earth ON position.
There is an option of supplying these cable compartments
with Internal Arc rating as per IEC standards.
b)Anti reflex mechanism:
Earth bar in cable
compartment
A fully rated copper earth bar
is mounted inside the cable
compartment. This earth bar is
used to connect the screened
cable connectors through M12
size bolts. The bar runs through
the width of the unit and
protrudes 125mm to the rear
of the cable compartment for
connection to the main earthing system. For additional
safety it is not possible to remove it while unit is live.

Ensures a time delay between switching operations to
allow sufficient time for the main breaker to trip and clear
a fault.
c) Internal Arc withstand
Aegis SF6 Gas insulated stainless steel tanks are fully
internal arc rated and this feature is also available on
the cable compartment (optional) to ensure maximum
operator safety in the event of internal faults. As
standard, all the tanks are rated for AFL (operator safety
from the front and side of the unit) and there is an option
to request for AFLR (front, side and back of the unit).
For more details on IAC ratings, please refer to the
technical data sheet on page 20.
d)Earth and test facility
The cable earth and test facility is an optional feature
on the Load Break Switch and the Circuit Breaker. It is
located at the front of the unit for ease of access. It is
used for testing cable insulation and to locate faults in
the circuit without the need to remove the main cables
from the cable compartment, which improves the
operator safety.
The cable test access cover
is fully interlocked and
cannot be opened until
the Load Break Switch or
Circuit Breaker Switch is in
Earth ON position. The test
bushings are earthed with
a star bar which has to be
removed for cable tests.
f)VPIS
VPIS (Voltage Presence Indication System) is an optional
feature in the Aegis range. It is used for checking the
presence of voltages in the cables. The VPIS gets a
voltage signal through the voltage divider built into the
cable bushings. They can also be fitted with neon lights
and momentary latching push buttons to show voltage
presence without needing external testing probes.
Two types of voltage presence indication device
are offered:
• Pfisterer sockets
• Neon indicators with push-to-test buttons and
phase comparator sockets
Pfisterer sockets
8
Neon indicator with
push-to-test buttons
6. Application examples
The key areas of application are:
a)Energy
i. Generation: wind power, solar power
ii.Distribution: compact substations
b) Infrastructure: tunnels, airports, ports,
underground railway stations
c) Commercial buildings: hospitals, shopping centres, hotels, office buildings, data centres
d) Industries: water and waste water, mining, minerals, automotive, iron and steel, paper and pulp,
cement and petroleum
9
7. Aegis range
presentation
The Aegis range has 3 and 4 functions insulated by SF6
gas in a single hermetically sealed stainless steel tank.
This solution is available in indoor and outdoor versions
and is perfectly suitable for integration into compact
substations to form standard Ring Main secondary
networks with transformer protection.
Switching functions:
• L; LBS (Load Break Switch) 400A and 630A
Circuit Breaker functions
• T: Vacuum Circuit Breaker 250/400A
• V: Vacuum Circuit Breaker 630A
8. Available configuration:
The configuration of switchgear is
very flexible; all L,T and V functions are
available in any combination either 3 ways
and 4 ways Non Extensible ranges.
Non extensible
(compact range)
Function positions in unit
Types of functions 1st2nd 3rd 4th
L
LLL
T
TTT
V
VVV
3 way units
4 way units
9.Standards
International Standards
IEC 62271-1
IEC 62271-100
IEC 62271-102
IEC 62271-103
IEC 62271-200
10
10.Product
characteristics
a) General
i. Product presentation
1
EFI
2
Pressure indicator
3
Marshalling Box
4
Optional VPIS
5
Earth and Test Facility
6
Protection Relay
7
'Push To Trip' Button
8
Circuit Breaker Indication
9
Interlocked Cable Box Cover
1
3
2
5
4
6
7
8
10
14
13
11
12
10 Disconnector Indication
9
11 Cable Test and Cable Box Interlock
15
12 Disconnector Operation Collar
13 Operation Collar
14 Switch Indication
15 Operating Handle
ii. User interface and interlocking mechanism
Safety interlocking
Each LBS and VCB module has safety interlocked access via a rotary knob on the fascia to enable access to the cable
connection compartment and also the cable test access panel (if specified as an option) located on the fascia.
Operating handle access shafts have the facility for individual padlocks.
Load Break Switch
Position
Load
Break
Switch
ON
OFF
OFF
Earth ON
Interlock status
Selector
Main
Main
Earth
Earth
Cable
compartment
interlock
Locked
Locked
Locked
Unlocked
Earth & Test
interlock
(if fitted)
Locked
Locked
Locked
Unlocked
Circuit Breaker
Position
Interlock status
Circuit
Breaker
Selector
ON
OFF (Tripped)
OFF (Reset)
Earth ON
Earth ON
OFF (Tripped)
Main
Main
Earth
Earth
Earth
Earth
Cable
compartment
interlock
Locked
Locked
Locked
Unlocked
Locked
Locked
Earth & Test
interlock
(if fitted)
Locked
Locked
Locked
Unlocked
Locked
Locked
11
b) Switching functions
L: LBS Load Break Switch
i. Standard features
ii. Optional features, factory fitted
• Three functions (ON, OFF & Earth), two position spring loaded mechanism, independent manual operation
• Internal arc rating of cable compartment for additional safety
• Single mechanism with two independent operating shafts, one for switch ON / OFF position and another for selecting in Mains and Earth operation
• Remote low gas pressure alarm,1N/O
(only one per tank)
• Interlocked selector, locked from operation when switch is in ON position
• Single line intuitive mimic diagram with clear indication to show the status of switch
(ON, OFF or Earth positions)
• Gas pressure indicator with Red and Green sectors to indicate minimum permissible pressure for safe operation (only one per tank)
• Horizontal cable terminations in front with DIN400 type C bushings
• Fully interlocked cable compartment allowing entry only if function is in Earth ON position
• Padlock facility (8.5mm diameter hole) for all the operating positions
12
• VPIS – Voltage Presence Indication System
• Remote switch position indicator
(1N/O,1N/C and 2N/O,2NC)
• Fully interlocked cable earth and test (E&T) facility without removing main cable connections
• Short circuit and Earth Fault Current Indicators (EFI)
• Wiring for motorisation
iii.Optional features also available
as retrofit
• Motor operation for Load Break Switch
(only if unit is pre wired for motorisation)
•
Wide range of cable clamps, and glands
to accommodate 1 and 3 core cables
(refer to cable compartment section on
page 17 for further information)
c) Circuit Breaker; T or V modules
T module 250A and 400A rated vacuum circuit breakers
for transformer protection
V module: 630A rated vacuum circuit breaker for
transformer / downstream network protection
i. Standard features
• Three functions (ON, OFF & Earth), two position spring loaded mechanism, independent manual operation
•
Single mechanism with two independent operating shafts, one for circuit breaker ON/OFF position and another for selecting disconnector in Mains or
Earth (isolation)
• Interlocked disconnector selector, locked from operation when circuit breaker is in ON position
• Mechanical push-to-trip button for local operation
• Trip coil for receiving tripping signal from relay or
TLF devices
• Protection function TLF or relay (customer specific)
• Single line intuitive mimic diagram with clear indication to show the status of switch
(ON, OFF or Earth positions)
• Gas pressure indicator with Red and Green sectors to indicate minimum permissible pressure for safe operation (only one per tank)
• Horizontal cable terminations at front of unit with DIN 400 C type bushings
• Protection CT (current transformers) mounted on cable bushings (customer specific)
ii. Optional features, factory fitted
• Internal arc rating of cable compartment for additional safety
• Remote low gas pressure alarm,1N/O
(only one per tank)
• VPIS – Voltage Presence Indication System
• Remote circuit breaker position indicator
(1N/O,1N/C and 2N/O,2NC)
• Fully interlocked cable test facility without the need to remove main cable connections (refer to cable test facility for further information)
• Self-powered relay for protection (customer specific)
• TLF (Time Limit Fuses) for alternative protection
• Wide range of Current transformers for TLF and
Relay protection
• Shunt trip coils for external tripping
• Wiring for motorisation
iii.Optional features also available
as retrofit
• Motor operation for CB (only if unit is pre wired
for motorisation)
•
Wide range of cable clamps, and glands
to accommodate 1 and 3 core cables
(refer to cable compartment section on
page 17 for further information)
• Fully interlocked cable compartment allowing entry only if function is in Earth ON position
• Padlock facility (8.5mm diameter hole) for all the operating positions
13
d) Circuit breaker protection
Two types of protection devices are offered
to protect the circuit breaker;
i. TLF : Time Limit Fuses
ii. Protection Relays
i.TLF
When utilised in conjunction with circuit breaker type
Ring Main Units, Time Limit Fuses (TLF) are a cost effective
method of providing fault protection for overcurrent
and earth faults (optional) to a transformer of 2000kVA
or less. It is a recognised method of protection and was
developed to comply with EA 41-26 (now superseded by
ENA TS 41-36) with fuse links in accordance with ENA
TS 12-6.
It should be noted that the TLF protection system is
not a device for limiting overload levels of individual
transformers. It should be used for fault protection only.
The TLF system provides protection for overcurrent and
earth faults between the MV Circuit Breaker and the LV
protection device. The selected TLF rating should be such
that it allows for discrimination between the MV & LV
devices. This will ensure that the Circuit Breaker does not
open for faults beyond the LV distributor
protection device.
When fitted with TLF, the Ring Main Unit can also be
configured to enable tripping of the Circuit Breaker
from remote devices (Bukholtz, LV CB etc).
Fuse dimensions: Length 57mm x Diameter 13mm
RMU
Lucy Switchgear customers in Europe, the Middle East,
Africa and Asia are currently using TLF protection system
within their distribution networks.
TLF
Transformer
LV distribution
Panel
14
Recommended TLF settings
Transformer ratings (kVA)
200
315
500
Rated Voltage (kV)
CT Ratio
50/5
Earth fault setting =
25A
(instantaneous trip)
CT Ratio
100/5
Earth fault setting =
30A
(instantaneous trip)
800
1000
1250
1600
2000
12.5A
12.5A
5A
15A
15A
5A
7.5A
TLF Fuse Rating (A)
3.3
6.6
11
13.8
24
10A
5A
3A
3A
3.3
6.6
11
13.8
24
5A
10A
5A
5A
10A
5A
15A
10A
10A
3A
15A
15A
5A
7.5A
15A
7.5A
5A
5A
12.5A
7.5A
7.5A
15A
10A
10A
Advantage of Vacuum Circuit Breaker with TLF
over HV fuses
Feature
VCB with TLF
Fuse Switch
Overall cost of units
Similar
Approximate fuse replacement cost
$5$50
Maximum rating of transformer, can be protected
2MVA* 1MVA
Maximum rated normal current
630A200A
Physical size of fuses
SmallLarge
Possibility of some pollution while changing fuses causing PD and flash over issues
NoYes
Fuse location inside the unit
LV side
HV side
Range of fuses required for different rated transformers
Very small with multi ratio CT
Large
*No issues with transfer current switching to IEC 62271-105, which minimizes the MVA rating
Advantage of Vacuum Circuit Breaker with TLF
over Protection Relays
Feature
Installation cost of function
Auxiliary power source for operation
Delay in activation of trip function due to capacitor charging time lag
Employee training on setting tripping curves
Additional training on different manufacturer setting up procedure
Maintenance and repair cost
Operating temperature limitations
Upstream and Downstream discrimination protection of circuit
Over current and Earth Fault protection
VCB with TLF
Protection Relay
LowHigh
Not required
As required
No delayDelay
Not requiredRequired
Not requiredRequired
LowHigh
None
Up to 70 °C
YesYes
YesYes
15
ii. Protection Relays
ManufacturerWoodward
Range
WIP1
Functions
Phase overcurrent
Short circuit protection
Number of overcurrent elements
Earth overcurrent
Number of Earth overcurrent elements
The Aegis range can be fitted with self-powered relays
for protecting the transformer or downstream network
from fault currents by tripping the Circuit Breaker. These
relays incorporate many advanced features and have a
variety of settings to provide discrimination protection in
networks. The self-powered feature eliminates reliance
on external power sources and increases the performance
and reliability of the protection function.
To the right are the technical characteristics of the
Woodward WIP1 relay, offered as a standard on the
Aegis range (if ordered with relay function). Other
manufacturers’ relays can also be incorporated
into the units on request.
Characteristics
Display (measuring values and parameters)
Setting via buttons
Standard CT
LED pickup
LED trip indicator
Flag indication output
Fault memory
Clock
Password protection
Electro impulse and relay contact output
Number of output relays
Input remote tripping
Interface
RS 485 interface with pro open data protocol
RS-485 interface with Modbus protocol
Additional power supply
Key • Standard
•
•
2
•
2
•
•
1A
•
•
•
•
•
•
•
3 C/O
•
O
O
O
O
O Option
Other manufacturers’ relays are also available on request,
please contact our local sales office for more information.
iii.Protection CT (Current transformers)
for TLF and Relays
The protection CT are used in conjunction with Relays
or TLF protection to protect a wide (kVA) range of
distribution transformers. A comprehensive range of
CT (current transformers) is available to suit varied
application requirements.
Dual Ratio CT 100/50/Dual Ratio CT 200:100/Triple Ratio CT 150:100:50/An extensive range of additional CT’s are available on request,
please contact our local sales office for more information.
16
e) Options and Accessories
i. Secondary injection
iv.Shunt trip coils
Secondary injection is used to test the relays or TLF
operation without switching on the high voltage supply
to the unit. A low voltage is applied to the secondary side
of the CT connection (located in terminal box) to test
the operation of the protection devices at the time of
commissioning and routine tests.
Shunt trips are magnetic
coils and are used to trip
circuit breakers through
local push buttons, RTUs
or additional transformer
protection devices. Shunt
trips are available in the
following voltages;
ii. Actuators (motorised)
Aegis units are fitted with 24V DC
motors, which can be powered
from the Gemini Remote Terminal
Unit (RTU) 24V DC battery in the
event of mains AC supply failure.
• DC voltage:
12V, 24V, 48V and 110V
• AC voltages:
110V, 240V
• Multiple voltage range: 24VDC – 240VAC
v. Earth Fault Indicators (EFI)
iii.Cable compartment
All the cable clamps, glands and cable compartment
sealing devices are available as retrofit options. Below is
the list of clamps available in metal (steel) and plastics.
• Single 3 core cable
• 3 single core cables
Earth Fault Indicators (EFI) are used for rapid location
and isolation of faults on medium voltage networks in
open loop ring main networks. When the unit detects
asymmetrical currents greater than 50A in the 3 phase
cable an earth fault is indicated by means of a flashing
LED or mechanical flag.
Below is the list of EFIs available for the Aegis range.
An extensive range of additional
cable compartment clamps and
sealing devices are available on
request, please contact our local
sales office for more information.
Single 3 core cable
Manufacturer:Suparule
Model:
Sensorform
3 single core cable
BLZ-50BFZ-50MFZ-50MLZ-50CFZ-50CLZ-50
Features Power source3.6V lithium ½ AA 110-240V a.c. CT on current
850mAH battery
carrying phase
Voltage range
1 – 38kV
Trip current
50A
Primary indication
LEDMech-flag (RED)
LEDMech-flag (RED)
LED
Flashing duration
>1000 hrs--
10 hrs-
10 hrs
Minimum fault duration
2.5 cycles
Manual reset
Push button
Automatic timer reset4 or 8 hrs selectable
10 secs after mains restore
Manual trip test
Push button
Operating temperature
-40°C to +80°C
Operating humidity
0-100% RH
Ingress protection
IP65
Current sensor diameter:
CT100: 100mm
••••••
CT150: 150mm
OOOOOO
CT300: 300mm
OOOOOO
Remote flashing LED indicator
OOOOOO
Auxiliary relay, 1N/O latching
OOOOOO
Key
• Standard
O Option
Other manufacturers’ EFIs are also available on request, please contact our local sales office for more information.
17
11.Switchgear
Automation
The Gemini RTU is an advanced, highly flexible and ultra-efficient solution
for remote operation and control of electrical distribution networks.
Enclosed in a stainless steel casing for maximum protection, the Gemini
RTU is designed to operate in the most demanding environments.
The key features of the Gemini range are:
• Embedded auto change over and auto
sectionalising functions
• Control and monitoring of up to 4 motorised functions (switches or circuit breakers)
• Inbuilt Earth and Fault Passage Indicators
• Advanced monitoring of current, voltage, battery condition, temperature compensation, switching status, automatic cooling system, gas pressure etc
• Flexible communication through radio, RS232, RS485, packet data network, GSM, GPRS, PSTN, Bluetooth,
Ethernet TCP/IP, optical fibre and SMS messaging
• Advanced battery back to operate under mains AC input failure
• Fully tested to ENATS (Energy Network Association Technical Standards), EMC and environmental standards
In addition to the features
opposite, remotely monitored
and controlled switchgear
provides significant benefits
to customers such as:
• Reduced time in diagnosing system anomalies as well as locating and isolating faulty sections of network
• Faster response time and quick
network reconfiguration
• Optimisation of asset management through the implementation of customised automation schemes
• Reduced operational cost associated with routine network switching
• Increased operator safety
Gemini RTU Specification
General
Enclosure
Stainless steel
Degree of Protection
IP54
Operating Temperature
-25 to 60°C
Relative Humidity
Up to 95%
Method of Mounting
Floor, wall, pole or RMU switchgear
Dimensions
H 600mm, W 400mm, D 210mm
RTU Hardware
Processor Module
ARM9 Microprocessor
Power Supply
110 / 230V AC supply – over and under-voltage protection
Battery Type
2 x 12V DC, sealed lead acid or high temperature NiMH
Battery Charger
Temperature compensated, fully protected
Control Electronics
PIC based processor with expandable I2C bus
Inner Enclosure
Stainless steel
Ventilation
Microprocessor controlled, long life fan with baffle air intake filter
Inputs / Outputs
Digital Inputs
14 isolated digital inputs – expandable
Digital Outputs
8 isolated digital outputs – expandable
Analogue Inputs
3 CT analogue inputs as standard (DIs reduced to 11)
Expansion I/O Module
3 AIs / 4 DIs; 7 DIs / 2 DOs
Communications
Communication Interfaces
3 RS-232 for Control (Ethernet option), Configuration and Programming plus one Expansion Bus
Protocols
DNP3, IEC 60870-5-101/104 and Modbus (others on request)
Communication Media
RS-232 / 485, UHF / VHF radio, Packet Data, GSM / GPRS / EDGE, PTSN,
Leased or Twisted Pair Lines, Optical Fibre, Ethernet (TCP/IP) and Bluetooth
Switchgear Interface
Controls
Membrane push-button for Open / Close operations in conjunction with Activate push-button up to four switching functions (standard 1, 2, 3 or 4 switch control formats)
Selector control for Off, Local or Remote modes
Indications
RTU services such as DC / AC supplies, Dummy Control and Debug LEDs
Switch status LEDs for Open / Closed positions
Control Output LEDs (illuminates when active)
Configurable LED indications
Cables
Plug-in, multi-core umbilicals to switchgear
Software
Configuration
Windows-based software for configuration of: • Protocol parameters including device and I/O addresses
• Parameters for the communications device
• Parameters for digital, analogue and counter points
• Automation sequences
• Power saving routines
• Battery tests
18
12. Cable bushings and
cable terminations
The bushings for each ring switch and
circuit breakers are located at the front
of the unit. All sets of bushings are type
‘C’ with in-line bolted connections M16
threaded in accordance with EN50181.
The bushings are accessible by removing the interlocked
cable compartment covers at the front of the unit.
The maximum cable size that can be used is:
• 300mm² 3 - core
• 500mm² single - core.
The following types of terminations can be used with
the Aegis:
Insulating Bushing Boot
Heat Shrink Insulating Bushing Boot
Profile 'C' Bolted Separable
19
13. Technical data sheet
General
Circuit Breaker V and T function
Rated Voltage
kV
1217.524
Rated normal current
Rated frequency
Hz
506050
Rated lightning Impulse withstand voltage
V function
A
630- -
T function
A
250250400
Directly earthed
kV
95 95125
Rated active load breaking current
A
630250400
Across disconnector
kV
110110145
Rated short circuit breaking current
kA
202120
Rated power frequency withstand voltage
Rated short circuit making current
kA
5054.650
Directly earthed
kV
383850
Rated cable charging breaking current
A
25 31.531.5
Across disconnector
kV
454560
Rated short time withstand current
Protection Main electrical circuit
Tank with HV parts
IPIP67
1 sec
kA
-21-
LV control box
IPIP41
3 sec
kA
20-20
Front face + mechanism
IPIP41
Earthing circuit
Cable box
IPIP41
1 sec
kA
-21-
Mechanical impact protection
IKIK07
3 sec
kA
20-20
Internal arc rating
Mechanical endurance class
Freestanding
kA 1 sec
21kA 1 Sec
Circuit breaker M1 / 2000
Optional cable box kA 1 sec
21kA 1 Sec
Earth switch
M0 / 1000
AFL (gas chamber)
Standard
Electrical endurance class AFLR (gas chamber)
Optional
Circuit breaker
E2/2000
Earth switch
E1
SF6 gas
Filled pressure
Bar (G)0.40.40.5
Operating mechanism
Minimum operating pressure
Bar (G)0 00.3
Tripping time
Annual leakage rate ≤0.01% per annum≥
Installation conditions
°C
Maximum altitude (without derating)*
M1000
405555
Relative humidity (max) - over period of 24hrs
(IEC 62271-1, sub-clause 2.1)
95%
* For higher altitude applications please contact local Lucy Switchgear sales office.
BusBars
A
630400400
Rated short time withstand current
1 sec
kA
-21-
3 sec
kA
20-20
Rated peak withstand current
kA
5054.650
Load Break Switch: L function
Rated normal current
A
630400400
Rated active load breaking current
A
630400400
Rated short circuit making current
kA
5054.650
Rated cable charging breaking current
A
101016
Rated short time withstand current: Main electrical circuit
1 sec
kA
-21-
3 sec
kA
20-20
Earthing circuit
1 sec
kA
-21-
3 sec
kA
20-20
Mechanical endurance class
Load break switch
M2 / 5000 M2 / 5000 M2 / 5000
Earth switch
M0 / 1000 M0 / 1000 M0 / 1000
Electrical endurance class short circuit making
Load break switch
E3 / 5
E1 / 2
E1 / 2
Earth switch
E3 / 5
E1 / 2
E1 / 2
Operating mechanism
Local: Close / Open
Hand Lever
Remote: Close / Open
Motor
20
> 80
> 80
> 80
Local: Close / OpenHand lever / Pushbutton
Ambient air temperature (without derating)
Rated normal current
ms
Operating sequence for mechanism 0-3min-CO-3min-CO
Remote: Close / Open
Motor / Coil
14.Dimensions
3 way
4 way
1235mm
1650mm
Side View
50mm
Dimension 'B'
Dimension 'A'
905mm
Cable termination height “B” (mm)
(Distance between cable clamp and bushings)
Reduced Standard
Tall
Overall height of Unit
Without E&T facility “A” (mm)
450
1100
6001250
8101450
1: L function height is not affected with addition of E&T facility
2: For V & T functions with E&T facility add 150mm to overall height “A”of the unit
21
15. Aegis Order Form
To use this form, please photocopy and return the completed form to your nearest Lucy Switchgear office
(addresses can be found on the back cover)
Name:
Company:
Address:
Tel No:
Fax No:
Email:
Order Number:
Order quantity / number of units (please fill separate form for each type)
IP rating: Installation conditions (choose any one)IP54 Metal clad outdoor
IP41 Indoor
Colour RAL7032 as standard (other colours are only available on request)
Features common to all functions
Voltage rating (choose any one)
12KV
17.5kV
24kV
Low gas Pressure alarm 1N/O (tick if needed, only one per tank)
Number of ways and functions needed at each position:
FirstSecond
ThirdFourth
(e.g. 1 function)
(e.g. 2 function)
(e.g. 3 function)
(e.g. 4 function)
Starting from the left, write any one of L, V or T in each box
depending upon the number of ways needed.
Voltage Range
Functions current ratings
12kV17.5kV24kv
L
630A400A400A
T
250A250A400A
V
630A– –
For example:
L
V
T
L
Motor wiring (tick for each selected function, if needed)
Motor for remote operation (tick for each selected function, if needed)
Cable Earth & Test facility (E&T) (tick for each selected function, if needed)
Cable bushings termination height (choose any one)
450
600
810
Cable box: Internal Arc proof VPIS (choose any one)
Neon indicator with push to test button
Pfisterer socket
Auxiliary switches (choose any one)
1N/O, 1N/C
2N/O, 2N/C
Cable compartment
Cable clamp material (choose any one)
Metal Plastic
Cable entry type (choose any one)
3 single core cable
Single 3 core cable
Optional features applicable to L (Load Break Switch) function only
Rated current (choose any one)
400 Amps (available for 17.5 and 24kV)
630 Amps (only available for 12kV)
EFI (choose any one)
BFZ-50
MFZ-50
MLZ-50
CFZ-50
CLZ-50
BLZ-50
Any other*
Optional features applicable to V or T (Vacuum Circuit Breaker) function only
Secondary injection (tick for each selected function, if needed)
Protection device (choose any one)
TLF (Time Limit Fuses)
WIP1
Other*
Protection (CT) current transformer for TLF or Relay (choose any one)
Dual (Primary) Ratio CT 100:50/-
Dual (Primary) Ratio CT 200:100/-
Triple (Primary) Ratio CT 150:100:50/-
Manual Push To Trip button (tick for each selected function, if needed)
Shunt Trips (choose any one)
12V DC
24V DC
48V DC
110V DC
110V AC
240V AC
Multiple voltage (24V DC - 240VDC)
Note: The ring main units gas chamber are supplied with AFL (Front and sideways) rating.
If you require units with AFLR (Front, side and rear) ratings please contact our local sales office.
*Please fill the details in comment section below.
Comments
Disclaimer
Lucy Switchgear has a policy of continuous research and development
and accordingly reserves the right to change the design and
specification of its products without prior notice.
Lucy Switchgear worldwide offices
Lucy Switchgear Ltd.
Howland Road, Thame, Oxfordshire,
OX9 3UJ, United Kingdom
Tel: +44 1844 267 267 General
Tel: +44 1844 267 222 Sales
Fax: +44 1844 267 223
Email:salesuk@lucyswitchgear.com
Lucy Switchgear Arabia Co. Ltd.
Novotel Business Centre,
P.O. Box 35340, Dammam 31488,
Saudi Arabia
Tel: +966 3 8147 910
Fax: +966 3 8147 914
Email:salessa@lucyswitchgear.com
Lucy Asia Pacific Sdn Bhd
L13A-03-03A, PJX-HM Shah Tower,
No16A Jalan Persiaran Barat,
46050 Petaling Jaya, Selangor, Malaysia
Tel: +603 74910700
Fax: +603 79316923
Email:salesmy@lucyswitchgear.com
Lucy Middle East FZE
PO Box 17335, Jebel Ali, Dubai,
United Arab Emirates
Tel: +97 148 129 999
Fax: +97 148 129 900
Email:salesme@lucyswitchgear.com
Lucy Switchgear (South Africa)
Unit 2, Cranberry Industrial Park, Cranberry Street
Laser Park, Honeydew, 2170, South Africa
Tel: +27 10 593 3034
Fax: +27 10 593 3035
Email:salesza@lucyswitchgear.com
Lucy Electric (Beijing) Co. Ltd.
卢西电器(北京)有限公司
北京市朝阳区东三环北路霞光里
18号佳程广场A座1122室
邮编:100027
电话:+86 1059 231 176
传真:+86 1059 231 177
电子邮件: salescn@lucyswitchgear.com
Postal Address:
P.O. Box 1078, Honeydew, 2040
To find out more about us, visit:
www.lucyswitchgear.com
LSAEG0613
Download