TemTrip2 is a multi-protection relay for medium or low voltage circuit breakers that is
capable of indicating via LEDs that the load current is picked up or the breaker trips open
and showing various information including the phase current, line voltage and fault current
on the LCD.
The relay is available in three types: for generator protection, feeder circuit protection, and
transformer protection.
aFeatures
s4HE ZEROPHASE VOLTAGE DETECTION SCHEME IS
USED TO DETECT A GROUND FAULT WHICH ALLOWS
THE RELAY TO APPLY TO A NONGROUNDED SYSTEM
WHERETHECURRENTISHARDTODETECT
s4HEDIRECTIONALGROUNDFAULTPROTECTIONSCHEME
PREVENTS NUISANCE TRIPPING DUE TO A GROUND
FAULTOCCURRINGOUTSIDETHEPROTECTIONAREAEG
ONTHELINESIDEOFTHEBREAKERORTHEPRIMARY
SIDEOFTHETRANSFORMER
s4HE RATIO DIFFERENTIAL CHARACTERISTIC PERMITS
APPLICATIONOFTHERELAYTOFAULTDETECTIONINOR
PROTECTIONOFVARIOUSDEVICESWITHINASYSTEM
SUCH AS TRANSFORMERS AND GENERATORS 4HE
BIAS FUNCTION ALSO SERVES TO PREVENT A MAL
FUNCTION
s4HE REVERSE POWER TRIP FUNCTION 022('
FOR GENERATOR PROTECTION ELIMINATES THE NEED
FORUSINGANEXTERNALREVERSEPOWERRELAY
s3EPARATIONOFTHECONTROLPOWERFORTHEPROTEC
TIONCIRCUITANDMEASURINGCIRCUITENHANCESTHE
REDUNDANCYANDRELIABILITY
<Specification>
s#ONTROLVOLTAGE!#6!#6$#6$#6
s%LECTRICPOWERCONSUMPTION6!
s$IMENSIONS7×(×$
s4HELONGTIMEDELAYSHORTTIMEDELAYANDIN
STANTANEOUSTRIPFUNCTIONSREMAINACTIVEEVEN
IFTHECONTROLPOWERISLOST
s)NFORMATIONDISPLAYEDONTHE,#$OFTHEFRONT
PANEL INCLUDES THE PHASE CURRENTS VOLTAGE
ELECTRICAL ENERGY DEMAND ELECTRICAL POWER
POWERFACTORTRIPPICKUPCURRENTANDFAULTCUR
RENTFAULTOCCURRENCETIME
aMeasurement/event indication function
,OADCURRENT
(Ò)
,INEVOLTAGE
(Ò)
%LECTRICALPOWER
(Ò)
%LECTRICALENERGY
(Ò)
0OWERFACTOR
(Ò)
4RIPEVENTLOG
!LARMEVENTLOG
0RESENTVALUEFOREACHPHASE
0RESENTMAXVALUE
0RESENTVALUEOFEACHLINEVOLTAGE
s/UTPUT SIGNALS INCLUDING CURRENT SIGNAL AND
VOLTAGE SIGNAL ARE ANALOG AND DELIVERED VIA
TO M! $# TERMINALS 4HE -ODBUS DATA
COMMUNICATIONFEATUREISAVAILABLEASANOP
TION
0RESENTVALUE
$EMANDVALUE
-AXDEMANDVALUE
%LECTRICALENERGY
s!N INTERNAL CLOCK ALLOWS THE FAULT OCCURRENCE
TIME TO BE DISPLAYED ON THE ,#$ AND UP TO
FAULTEVENTSANDALARMEVENTSTOBE
VIEWEDINCHRONOLOGICALORDER
0RESENTVALUE
&AULTCURRENTÒ
)NDICATIONOFCAUSE
&AULTOCCURRENCETIME
#AUSEOFALARM)NDICATIONOFOPERATEDVALUE
s4HE SELFDIAGNOSTIC FUNCTION COMES STANDARD
WITHTHERELAYPROVIDINGANALARMVIAARELAY
CONTACTOUTPUTIFANERROROCCURSINTHE#05
aProtective function
!DJUSTABLELONGTIMEDELAYTRIP
!DJUSTABLESHORTTIMEDELAYTRIP
!DJUSTABLEINSTANTANEOUSTRIP
!DJUSTABLEUNDERVOLTAGETRIP
!DJUSTABLEOVERVOLTAGETRIP
!DJUSTABLEREVERSEPOWERTRIP
!DJUSTABLE
/VERVOLTAGEGROUND
GROUNDFAULTTRIP $IRECTIONALGROUND
2ATIODIFFERENTIALTRIP$)&&
0RETRIPALARM
LT
ST
).34
56
/6
202
/6'2
$'2'
'
4
04!
04!
PRR-1H-G
Generator protection
○
○
○
○
○
○
○
○
○
̶
○
○
○ 3TANDARD △ /PTIONAL
JAN. #ATALOGUE.O
’
-PE
※ Ratings and specifications in this catalogue may be subject to change without notice
PRR-1H-F
Feeder circuit protection
○
○
○
△
△
̶
○
○
̶
̶
○
̶
PRR-1H-T
Transformer protection
○
○
○
̶
̶
̶
○
○
̶
○
○
̶
Download