Amana Technical Information Refrigerator Wiring Diagram ! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on connect terminals to ensure proper grounding and polarization. ARB1905C* ARB1917C* ARB2205C* ARB2214C* ARB2217C* DRB1901C* DRB2201C* PARB1905CB0, PARB1905CC0, PARB1917CB1, PARB1917CC1, PARB2205CB0, PARB2205CC0, PARB2214CB1, PARB2214CC1, PARB2217CB0, PARB2217CC0, PDRB1901CC0, PDRB1901CW0 PARB2201CC0, PARB2201CW0 PARB1905CW0 PARB1917CS0, PARB1917CW1 PARB2205CW0 PARB2214CS1, PARB2214CW1 PARB2217CS0, PARB2217CW0 • Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator. • Refer to Service Manual RS1200005 for installation, operating, disassembly, icemaker, testing, and troubleshooting information. ! CAUTION All safety information must be followed as provided in Service Manual RS1200005. ! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless testing is required. Discharge capacitors through a 10,000 ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. Kw/24 hr ± 0.4 Ambient ° F 19 cu ft 22 cu ft 65° .9 .9 90° 1.4 1.5 110° 2.0 2.1 No-Load Performance, Controls in Normal Position Refrigerator Center Compartment Percent Run Time Average Food Cycles/24 hr ± 10% Temperature ± 3°° F ± 25% 65° 25 25 90° 40 40 110° 60 60 65° 33 30 90° 30 27 110° 24 22 65° 38 38 90° 40 40 Freezer Compartment Average Food Temperature ± 3°° F 110° 42 42 65° 0 0 90° 0 0 110° 0 0 Temperature Relationship Test Chart Ambient ° F 19 cu ft 22 cu ft T-1 Outlet ± 3°° F 65° 90° -15 -14 -15 -14 T-2 Inlet ± 3°° F 65° 90° -15 -14 -15 -14 T-3 Suction Line ± 7°° F 65° 90° 65 95 65 95 Average Total Wattage ± 10% 65° 90° 135 140 135 140 Suction Pressure ± 2 In. Hg 65° 0 0 90° 1 1 Head Pressure ± 5 PSIG 65° 90° 83 135 83 135 Schematic November 2001 Amana Appliances 2001 4 12642402 Rev. 0 November 2001 1 12642402 Rev. 0 Component Specifications ! Damper Replacement ! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on connect terminals to ensure proper grounding and polarization. WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on connect terminals to ensure proper grounding and polarization. Replacing Damper Control Part Number Component C8931612 Compressor run capacitor 12049717 Compressor 12571702 Damper control Specifications all parts 115VAC/60HZ unless noted Volt..................................................... Capacitance ...................................... BTUH ................................................. Watt ................................................... Current Lock rotor.............................. Current Full load................................. Resistance Run windings................... Resistance Start windings.................. 12351008 Freezer temperature control Settings #1 – out.............................................. #4 – in ................................................ #4 – out.............................................. #7 – out.............................................. 10884507 Condenser motor Rotation (facing end opposite shaft) RPM Watt.................................................... Current............................................... 210/220 VAC 15 µfd ± 10% 865 BTUH 60 Hz / 168 watts 19.5 amps± 15% 1.35 amps± 15% 2.79 ohms ± 15% 4.49 ohms ± 15% Closing temperatures 34.0°F 27.0°F 20.0°F Temperatures -0.6°F ±3° 10.0°F ±1.5° -8.0°F ±1.5° -17.9°F ±3° Clockwise 1100 RPM 8.6 watts±15%@115VAC 0.11 amps± 15%@115VAC 10449510 Evaporator fan motor Rotation (facing end opposite shaft) RPM…………………………………… Watt……………………………………. Clockwise 2800 RPM 5.9 ±15% watts@115VAC 12555902 Overload/Relay 12639301 Thermostat 12049801 Evaporator heater 12566301 Defrost timer C3680310 Light switch 12466103 Light switch / Interlock Settings #1....................................................... #4....................................................... #7....................................................... 1. Remove lens cover by removing hex head screw in lens cover. Slide cover rearward and drop down to remove. 2. Remove damper control cover and foam insert by pulling straight down on sides of rear cover and tilt forward approximately ½” to 1”. This will release the cover from the tabs holding it in place. FOAM INSERT DAMPER CONTROL COVER 3. Ult. trip amps @ 158°F (70°C)............ Close temperature............................ Open temperature............................ Short time trip (seconds) .................... Short time trip (amps @77°F (25°C)... 3.51 amps± 15% 142°F ±6° 257°F ±3° 10 seconds ±5 14 amps ±2amps Volt .................................................... 120/240 VAC Watt ................................................... 1000 watts Current............................................... 10/5 amps Resistance across terminals: Above 42°F ±5°.................................. Open Below 12°F ±7° .................................. Closed Volt..................................................... 115 VAC Wattage.............................................. 450 ±5% watts @ 115VAC Resistance......................................... 29 ±5% ohms Volt..................................................... Defrost period (minutes)……………….. Defrost cycle (hours)…………………… Type…………………………………….. Volt……………………………………… Current………………………………….. Release tension on damper control belt by squeezing tabs on bottom of belt tensioner to release tensioner from it’s holding tabs. BELT TENSIONER 4. Damper can be removed by pushing in tabs on left and right side of damper control to release damper from rear wall. 120VAC, 60 HZ 33 ± 3.6 8 SPST NC 125/250 VAC 8 / 6 amps Type…………………………………….. SPDT NO/NC Volt……………………………………… 125/250 VAC Current………………………………….. 8 / 6 amps RELEASE TABS 5. 6. 7. 8. November 2001 2 12642402 Rev. 0 Install new damper in reverse order. When installing belt align large slots on belt with large cogs on damper and control knob gear. This will synchronize control knob with damper control. Install belt tensioner on mounting tabs and turn counter clockwise to increase tension on belt. Reinstall damper control cover by hooking bottom on tabs and rotating up until it snaps into place. Reinstall lens by sliding lens cover forward on tabs and installing hex head screw. November 2001 3 12642402 Rev. 0