FID analyzer system for Total hydrocarbons from ppb to LEL and VOC to TOC: THERMOFID EN 12619 Determination of the mass concentration of total gaseous organic carbon at low concentrations in flue gases - Continuous flame ionisation detector method Explosion protection according EN50054 en EN50057, thermal and catalytic oxidizers, regenerative thermal oxidizers (RTO), vapor recovery units (VRU) scrubbers, industrial furnaces. SIL approval. EN-IEC 61779, EN-IEC 60079 Alternative for Flammability FTA Flame Temperature analyzer Prevex SNR van Control Instruments Inc. Emission measurement of total organic carbon according EN-IEC 13526, EN-IEC 12619, 17. BImSchV, TA-Luft, MCerts (Guideline 2000/76/EG), , VDI 3481/3, CvGM-VKL-013. • Measurement of total organic C. according MCerts 2000/76/EG • Emission measurement on incinerators (EN 12619 en EN-13526) • Detection and measurement of flammable gases according EN-IEC 50054 + EN-IEC 50057 • ppb to Vol % CxHy in air, nitrogen, CO2 , steam and condensate. • T90 time < 2 seconds • Interference 0 - 25 Vol % O2: < 3 % Span • Option for methane / non methane analysis • Analyse of TOC + CO&CO2 in N2, Argon, Helium, H2 en • Designed to measure chlorinated hydrocarbons THERMOFID Analysis of hydrocarbons at all levels TOC, VOC, VOS, TC, TC - CH4, TC + CO + CO2, 3 mg C/m , ppm, Vol %, mg CxHy, L.E.L. Multifunctional The THERMOFID is used in a variety of industrial applications, environmental measurement systems and R&D projects. Typical use of the Thermo-FID are LEL control, flue/exhaust gas at waste incinerators or the petrochemical industry, ambient air analysis, work place control MAK/TRK-limits and process control optimization. Microprocessor for optimal control and operation The microprocessor controlled Thermo-FID provides menu driven ‘clear text’ user friendly interface information on an alphanumeric display. All operational and self diagnostic data are also available on RS232 and/or analog/digital outputs (status alarm PCB, optional). A fully automated and continuous self diagnostic and log book entries for all operation and calibration data guaranties an optimum analyzer up time. The unique close couple detector design (no cables, etc.) provides a low drift operation and a wide dynamic range with always optimum signal noise ratio. All digital input feature are designed according NAMUR guidelines, all digital outputs are potential free contacts. Analogue output signals are offered as standard 1x 0/420mA, 600 Ohm load (not galvanic isolated), optional 4 x 0/4-20mA optical galvanic isolation is available on the status & alarm card. Instrument operation, configuration and remote control is also available on 2 x RS232. The measurement principle of the Thermo-FID is based on the ionisation of hydrocarbons in a hydrogen flame. An exceptional constant sample gas flow and a constant hydrogen stream are drawn to the burner nozzle which being on a negative potential measured by the close coupled detector. In the temperature controlled burning chamber, the mixture is burned by adding hydrocarbon free air in relation of approx.10 : 1. The resulting ions are collected on a polarized electrode, amplified and put to display Best measurement performance is provided by offering a very constant sample mass flow and pressure conditions the Ionisation chamber.Detector Due to the THERMOFID to Flame Maximum reliability minimal maintenance optimum design of the instrument, pressure variation at the sample point are The corrosion proof detector is heated to 200 °C. 800mbar Twin air-jet abs. • up allowedupbetween to 1600mbar without lack of Complete diagnose of allabs. utilities aspirators for the sample flow in a heated detector never wear performance. out. Flow controllers, sensors and valves get in contact only with clean (compressed) air, hydrogen and span gas. This in combination with the dilution of the sample gas with compressed air as exhaust gas, results in an analyser with low service costs and high availability.. Service The modular design of the THERMOFID en the accessibility of essential parts in the detector guarantee a simple service and maintenance on-site. Specialists with decades experience on analyser and sample-handling with FID´s will assist you with advice and engineering, coordination of the system integration and assistance before during and after start up. • Automatic control & adjustment of flame temperature • Automatic start up • Automatic calibration including shut off valve • Heated corrosion proof detector • Maintenance free air-jet pumps • A/D converter direct at the measuring electrode • Sample gas pressure 800 to 1600 mbar absolute • Integrated catalyser for Zero and burner air THERMOFID Technical data Supply Consumption Analogue output Serial output Input Output Compressed air Hydrogen Q. 5.0 Spangas : : : : : : : : : 230/115 V~, 50..60Hz 250 VA 1 x 0(4)-20 mA (600 Ω) RS 232, Epson / HP compatible 1 x PT 100 for heated line or probe, adjustable: 60 … 210 °C 930 VA for heated line or probe 3 5 bar Abs. / 2Nm /h 2 bar Abs. / ca 40 ml/min 3 bar Abs. / 130 ml/h during calibration Analytical data Range Detection limit Response T90 Response T90 Sample Flow Inlet pressure Detector temp. 3 : 0 … 1 mg org. C/m to 100 % LEL 3 : < 0,1 mg org. C/m 3 : < 0,5s at a measured value > 20 mg org. C/m , excl. sample line 3 type MK with 0,5m probe < 3s at a measured value > 20 mg org. C/m 3 < 2 s with optional dilution for MK range > 20 mg org. C/m : according 17. BimSchV: 5s type MK with 0,5m probe < 7,5s : aspiration by air jet ; 10, 25 or 60 l/h at 1013 mBar : 800 – 1600 mBar. : 110 … 200 °C Housings 19” Rack 84TE/3HE type ES Dimensions : 132,5 x483 x 271 mm (HxWxD) Protection : IP 20 Table top 84TE/3HE type TS Dimensions : 135 x463 x 275 mm (HxWxD) Protection : IP 20 Wall mount type FE Dimensions : 450 x 440 x 400 mm (HxWxD) Protection : IP 54 Direct extraction type MK Dimensions : 450 x 440 x 400 mm (HxWxD) Pretection : IP 54 Probe : Flange DIN 2527 PN16 Form B DN80 I/O card status & alarm 3 x D/O 4 x A/O 4 x D/O 2 x A/I 2 x D/O 2 x D/I 2 x D/I 1 x D/O : Fault, Service, Maintenance (potential free contact) : 4, 0(4)-20 mA, galvanic isolation, 600 Ω : Alarm relay, free programmable (potential free contact) : Pressure transmitter for gas utilities (H2 , span), included 24Vdc supply : 24VDC/ 500mA, for H2 switchover : for Auto-Cal, Start & Cal Stop : free selectable status parameter : 24VDC/ 500mA, free selectable timer ••••••••••••••••••••••••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • THERMOFID accessories MSU 2 x 8 points Sample flow Flow Flowalarm Tubing Sample tube Selection Output : Parallel with air jet, for area measurement of TOC, VOC, VOS. : 35 Nl/h : each sample point : ø 4mm id / 6mm od : max 70 mtr per point : Programmable by ThermoFID extern by optional I/O card : Analogue 0(4)-20 mA per point (option) Potential free contact per point (option) . TOC/VOC in steam Pressure Points Housing Heating Selection Output : 2 – 16 bar : 1, 4 of 8 : Stainless steel : Electric up to 180 °C alternative by steam or condensate (6bar) : Programmable by ThermoFID extern by optional I/O card : Analogue 0(4)-20 mA per point (option) Methane / Non methane THC CH4 Linearity Zero drift T90 O2 influence SPAN gas : 10 to 1.000 ppm C3H8 with zero air via catalyser 2 tot 1.000 ppm C3H8 with zero air N2 : 10 tot 1.000 ppm CH4 with zero air via catalyser 2 tot 1.000 ppm CH4 with zero air N2 at THC < 100 ppm C3H8 methane failure is < 1 ppm : < 1 % of measured value : < 1 % of measured value /24h : THC< 15 sec, CH4 < 30 sec : < 4% of measuring range at 8 to 25 Vol% O2 : CH4 in air THC + CO + CO2 Principle Range Sample gas Catalyser Maximum : catalyser for CO and CO2 with H2 to CH4 : 0,01 ppm to 300 ppm THC : 0,2 to 4 bar : 350- 370 °C, controlled at 1 °C : 300 ppm CO/CO2 as sum Explosion proof: Versions Zone Approval : FE: Wallmount MK: Direct mounting to stack : Zone 1 and Zone 2 versions : BVS 09 ATEX E 119 X (ATEX 94/9/EG) IIC 2G Ex px II T2-T4 BVS 09 ATEX E 144 X (ATEX 94/9/EG) II 2/3G Ex pz II T2-T4 EEx p versions have limited pressure and temperature specifications. Compur Monitors SARL 155 Avenue du General de Gaulle F-92140 Clamart Phone: +33 145378951 Fax : +33 145378856 E-Mail: compur@compur.fr Compur Monitors BV (Benelux) De Veldoven 49 3342 GR Hendrik Ido Ambacht (NL) Telefoon : +31(0)78 – 682 05 37 Fax : +31(0)78 – 682 19 36 E-mail : info@compur.nl Internet : www.compur.nl / be • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •