SQUARE Light Sheets: SP - PLS - Stockholm Lighting Company AB

advertisement
Project:
Date:
Type:
Specified by:
SQUARE is the building block for backlighting.
ƒƒ A simple, uniform, and highly configurable light sheet that is ideally
suited for architectural backlighting applications where minimal setback
distances and high quality illumination are critical.
ƒƒ Designed for simple snap-together installation, SQUARE is perfect for
illuminating display walls and luminous ceilings or backlighting
architectural features that use glass, onyx, fabric and other materials to
create unique designs.
ƒƒ SQUARE is available in nominal 12”x12” sheets with high output or low
power versions in a range of color temperature options, all taking
advantage of the high degree of color consistency that results from
mixing a large number of small sources together.
Product Ordering Codes
SQUARE Light Sheets:
SP - PLS - ___ - K __ - U - 12-12
Light Output
600 lm = 600
300 lm = 300
Color Temperature (CCT)
2700K = 27
3000K = 30
3500K = 35
4000K = 40
5700K = 57
ƒƒ
ƒƒ
ƒƒ
ƒƒ
Examples:
600 lumens per sheet; 3000K CCT =
SP-PLS-600-K30-U-12-12
300 lumens per sheet; 5700K CCT =
SP-PLS-300-K57-U-12-12
SQUARE Wire Harness: 10-0680
SQUARE Starter Cable: 10-0306
Extension Cable (Optional): EXT-CBL-WLxxxx (xxxx = length in mm)
For LED Driver Options, please see page 4 “Cooledge UL Listed Drivers”
Cooledge Lighting reserves the right to change materials or modify the design of its product without notification as part of the company’s
continuing product improvement program.
120 – 13551 Commerce Parkway
Richmond, BC V6V 2L1
Phone (Toll Free): +1 844.455.4448
cooledgelighting.com
CESS-0020-021615 1/6
Vancouver
|
Munich
System Components
SQUARE Light Sheet
PN: SP-PLS-x00-Kxx-U-12-12
UL Listed Driver
PN: EDRV-0x0W-UNV-058-010-1104-3-SM
UL Listed Extension Cable
(if required)
PN: EXT-CBL-WLxxxx
SQUARE Wire Harness
UL Listed Starter Cable
PN: 10-0680
PN: 10-0306
SQUARE Light Sheet Detail
Snap connectors
(termination end)
LEDs
Side rails
Side rail post
(far side)
Cut lines
Holes for mounting screws
Side rail alignment slot
Snap connectors
(input end)
Cooledge Lighting reserves the right to change materials or modify the design of its product without notification as part of the company’s
continuing product improvement program.
120 – 13551 Commerce Parkway
Richmond, BC V6V 2L1
Phone (Toll Free): +1 844.455.4448
cooledgelighting.com
CESS-0020-021615 2/6
Vancouver
|
Munich
Dimensions
Snap connector allows
sheets to be electrically
connected together
Mounting rails assist
alignment and make
mounting easy
12”
11.7”
Cut Increments
9.4"
Sheets can be cut in increments of ~2.4” (61mm)
7"
7”
2.2"
4.6”
4.6"
9.4”
2.2”
Cooledge Lighting reserves the right to change materials or modify the design of its product without notification as part of the company’s
continuing product improvement program.
120 – 13551 Commerce Parkway
Richmond, BC V6V 2L1
Phone (Toll Free): +1 844.455.4448
cooledgelighting.com
CESS-0020-021615 3/6
Vancouver
|
Munich
Sheet Light Output and Power
Order Code
SP-PLS-600-Kxx-U-12-12
SP-PLS-300-Kxx-U-12-12
Light Output
(lm/ft2)
600
300
Light Output
(lm/m2)
6500
3250
Nominal Power
(W/ft2)
5.0
2.4
Nominal Power
(W/m2)
53.7
25.8
UL Listed Drivers
90W/50W/30W Constant Voltage
Nominal input voltage range (VAC): 120-277
Output Voltage (VDC): 58
Products
EDRV-090W-UNV-058-010-1104-3-SM
EDRV-050W-UNV-058-010-1104-3-SM
EDRV-050W-UNV-058-010-0606-4-SM
EDRV-030W-UNV-058-010-0606-4-SM
EDRV-090W-UNV-058-010-1212-6-SM
Dimming Protocol: 0-10V
Dimming Range: 1-100%
Rated
Output Power (W)
90
50
50
30
90
Dimensions
11” x 4” x 3”
11” x 4” x 3”
6” x 6” x 4”
6” x 6” x 4”
12” x 12” x 6” (IC Rated)
ƒƒ Cooledge drivers are compliant with IEC Standard 60929 Annex E (Ballasts) for 0-10V dimming
Remote Driver Distance
600lm
Configuration
16AWG
14AWG
12AWG
2x9
9
14
22
300lm
3x6
19
31
49
4x4.4
22
35
56
2x12
15
24
38
4x8
15
24
39
6x6
8
13
20
Layout Details
SQUARE Type
SP-PLS-600-K__-U-12-12
SP-PLS-300-K__-U-12-12
Light Output
(lm/sheet)
600
300
Maximum # Sheets
per 90w Driver
18
36
Maximum # Sheets
for Single Run
9
13
ƒƒ For small setbacks (2”-3.5” - dependent upon diffuser material) the SQUARE system has been optimized for 12”
O.C. spacing to maintain constant distance between LEDs on the sheets
ƒƒ For larger setbacks, sheets may be spaced further apart while maintaining uniformity of illumination
Cooledge Lighting reserves the right to change materials or modify the design of its product without notification as part of the company’s
continuing product improvement program.
120 – 13551 Commerce Parkway
Richmond, BC V6V 2L1
Phone (Toll Free): +1 844.455.4448
cooledgelighting.com
CESS-0020-021615 4/6
Vancouver
|
Munich
Wiring Details (Dimming)
Sheet-to-sheet Connections:
Simple snap-in connectors
Driver Connections:
Starter Cable (18ga shielded cable)
Extension Cable if required (size determined by remote driver distance)
Dimming:
0-10V input
SQUARE LIGHT SHEET
GREY
VIOLET
DIMMER
OPTIONAL - BY OTHERS
WIRE HARNESS
LINE
VIOLET
BLACK
NEUTRAL
GREY
WHITE
GREEN/YELLOW
DRIVER
RED
BLACK
EARTH
WIRE
NUT
ELECTRICAL ENCLOSURE
EXTENSION
CABLE
(IF REQUIRED)
STARTER
CABLE
CRIMP
CONNECTOR
Photometrics
198
149
99
2
50
1
Distribution: Available CCTs: CRI: Color Uniformity: Lumen Maintenance*:
Efficacy: Dimming Range: Lambertian
2700K, 3000K, 3500K, 4000K, 5700K
>80
<3.5 SDCM (Consult factory for other options)
L90 > 100,000 hours
*projections based on LM-80 data & TM-21 calcs
120 lm/w - 125 lm/w
1% to 100% Continuous
Maximum Candela = 99.22 Located At Horizontal Angle = 67.5, Vertical Angle = 1
# 1 - Vertical Plane Through Horizontal Angles (67.5 - 247.5) (Through Max. Cd.)
# 2 - Horizontal Cone Through Vertical Angle (1) (Through Max. Cd.)
Cooledge Lighting reserves the right to change materials or modify the design of its product without notification as part of the company’s
continuing product improvement program.
120 – 13551 Commerce Parkway
Richmond, BC V6V 2L1
Phone (Toll Free): +1 844.455.4448
cooledgelighting.com
CESS-0020-021615 5/6
Vancouver
|
Munich
Electrical
Environmental
Input Voltage: 58VDC
Power Supply: UL Class 2 Power Supply required
(Supplied by Cooledge - see “UL Listed Drivers”)
Accessories
Operating Temperature: 0° to 40°C (32° to 104°F)
Location: Indoor, dry location only
Humidity: 90% max relative (non-condensing)
No Mercury, UV or IR
Regulatory
UL 2108
ƒƒ SQUARE Wire Harness: 10-0680
ƒƒ SQUARE Starter Cable: 10-0306
ƒƒ Extension Cable (Optional):
EXT-CBL-WLxxxx (xxxx = length in mm)
Warranty
TEM WA
RR
SYS
A
SY
Y
E
5Y
R
5
NT
5Y
EA
R
TY
AN
Substrate: Flexible Polyethelene Terephthalate (“PET”)
Mounting Options:
Rails with holes for fasteners (fasteners/tape not included)
ƒƒ Mechanical Fasteners
ƒƒ Double-sided tape
A
Mechanical
S T E M WA R
R
5 Year Limited Warranty: Parts and
workmanship when used with a Cooledge
approved power supply.
Cooledge Lighting reserves the right to change materials or modify the design of its product without notification as part of the company’s
continuing product improvement program.
120 – 13551 Commerce Parkway
Richmond, BC V6V 2L1
Phone (Toll Free): +1 844.455.4448
cooledgelighting.com
CESS-0020-021615 6/6
Vancouver
|
Munich
Download