Data Sheet Ruggedized 19” Gigabit Ethernet Switch

advertisement
Data Sheet
Ruggedized 19” Gigabit Ethernet Switch
with Ring Recovery and PoE+
Picture
Overview
The new hardened 19” switch from MICROSENS, offer maximum performance and
flexibility in smallest spaces. Robust and designed for greatest reliability and shortest
recovery times, the hardened MICROSENS switch family has become the first-choice
solution for Industrial Ethernet.
The hardware of the hardened 19” switch is designed today for future functions, which
are easy to activate with firmware upgrades. This is facilitated by the latest highperformance switching chipsets in combination with a powerful ARM processor. As an
established, stable operating system, Linux offers a solid foundation for an intelligent,
open and long-term reliable platform.
Highlights

Highest Gigabit performance with smallest dimensions

Industrial design for maximum reliability in harsh environments

25 Gigabit (8 of them with fiber) ports on only 1U in 19” racks

Optimised architecture for increased performance with parallel ring topology

PoE+ (max. 30 W per port) integrated

Modular SD-card for firmware and configuration

Flexible firmware architecture for simple software upgrades

Redundant power inputs
©2014_MICROSENS GmbH & Co. KG_Küferstr. 16_59067 Hamm/Germany_www.microsens.com
Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch
Page 2/13
Specifications
Gigabit Ethernet Switch
Power-over-Ethernet PoE/PoE+
 Fanless Gigabit Ethernet Switch
 IEEE 802.3af PoE (max. 15 W/Port),
power supply with typ. 48 VDC
 Low power consumption switchchipset, Energy-Efficient Ethernet
 Layer-2+ store-and-forward
 Max. 8.192 MAC-addresses, automatic
Learning and aging
 Jumbo-Frames (max. 10,240 Bytes)
Energy-Efficient Ethernet
 EEE according to IEEE 802.3az
 Reduced power consumption for each
RJ-45 port up to 80% depending on
the actual requirement
Network Management
 Supports all common management
standards
 High Performance 800 MHz ARM CPU
 Linux operating system with fast
system boot (approx. 20 seconds)
 Web Manager (HTTP/HTTPS)
 Telnet/SSH/Console, incl. standardcommands (ping etc.)
 SNMP v1/v2c/v3 with
View-based Access Control Model
(VACM) and User-based Security
Model (USM)
 Central management platform
(NMP Professional / NMP Server)
 IEEE 802.3at PoE+ (max. 30 W/Port),
power supply with typ. 54 VDC
 16x 10/100/1000Base-T, PoE+ (PSE)
 1x 10/100/1000Base-T, PoE+ (PD)
Connectors (Base-Switch)
Up-/Downlinks (Dual Media-Ports)
 8x SFP-Slot 100/1000Base-X
 8x 10/100/1000Base-T (RJ-45)
Local Ports
 17x 10/100/1000Base-T (RJ-45)
Auto-Negotiation
 Auto MDI/MDI-X function for the use
of uniform patch cables
Power Supply
 3-pin screw pluggable connector for
solid or litz wires
RS-232 Console Port
 Serial terminal port for CLI access
(outband management)
USB Extension Port
 For optional accessories
Alarm Contacts / I/O-Ports
 Potential free digital input/output
ports
 2x output (relay)
 IPv4/IPv6 Dual Stack
 2x input (optocoupler)
 Integrated CLI scripting for the
automation of routine processes
Mounting
 Firmware-, Script- and configuration
files can be loaded, stored and
executed direct from the switch
 Mounting into 19” racks requiring 1U
space
 Incremental firmware updates
possible
 Modular SD memory card for the
configuration, CLI scripts, firmware
©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch
Page 3/13
Feature overview network management
IP Stack
Dual Stack
Parallel handling of IPv4 and IPv6 protocol.
IPv4 Stack
Internet Protocol v4 handling with support of IPv4, ARP, DHCP, ICMP.
RFC 791 (IPv4), RFC 826 (ARP), RFC 792 (ICMP), RFC 2131 (DHCP)
IPv6 Stack
Internet Protocol v6 handling with support of IPv6, DHCPv6, ICMPv6, NDP.
RFC 2460/2464/3484/3513 (IPv6), RFC 2462 (Address Configuration), RFC 2463
(ICMPv6), RFC 2461 (Neighbor Discovery Protocol), RFC 3315 (DHCPv6)
Port Control
Administration
Port disable, Individual port alias
Ethernet Copper
Auto-Negotiation, speed, duplex mode, flow-control, Auto MDI/MDI-X
Ethernet Fiber /
SFP
Speed, duplex mode, flow-control
Green IT
Latest chip technology supports Energy-Efficient Ethernet (EEE) according to
IEEE Std. 802.3az.
Power-over-Ethernet (PoE)
Function
Sourcing of power to connected devices via standard network Twisted-Pair cable
802.3at mode
PoE+ voltage is turned on only after powered device (PD) is detected and
classified on port. Output voltage and power is monitored. Port power is shut
down if limits are exceeded.
802.3af mode
PoE voltage is turned on only after powered device (PD) is detected and
classified on port. Output voltage and power is monitored. Port power is shut
down if limits are exceeded.
Power Management
Power limit can be defined per port and per total device. Additionally the class of
the powered device (PD) can be limited per port.
Standards
IEEE Std. 802.3af (Data Terminal Equipment Power via Media Dependent
Interface), IEEE Std. 802.3at (Data Terminal Equipment Power via Media
Dependent Interface).
Switch Functions
Port Monitor
Monitor port for the connection of a network protocol analyzer. Traffic of the port
to be analyzed is copied to the monitor port.
RMON counters
17 Integrated counters for detailed traffic analysis and network trouble shooting.
MAC Table
Access to table of MAC addresses learned by the switch. Can be filtered per port,
VLAN address type and entry type (dynamic/static).
Virtual LANs (VLANs)
Function
Logical structuring of physical networks by adding a Virtual LAN ID (VID) to each
Ethernet packet. Incoming packets are filtered and forwarded according to their
VID. Each port can be configured for Access, Hybrid or Trunk VLAN processing
mode. Independent VLANs out of the full range of 1 to 4095 can be filtered per
device.
Access Mode
For the connection of non-VLAN capable end devices (e.g. PCs). Outgoing
packets are sent untagged. Incoming packets are tagged with the port default
VLAN ID (PVID).
Trunk Mode
For the interconnection of VLAN capable switches. Outgoing packets are always
sent tagged. Incoming packets are received tagged. Incoming packets without
VLAN tag are tagged with the port default VLAN ID (PVID).
©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch
Page 4/13
Hybrid Mode
For the connection of VLAN capable and non-VLAN capable devices on the same
port (e.g. VoIP-phone (tagged) and PC (untagged)). Outgoing packets are sent
tagged, except packets for the port default VLAN ID (PVID), which are untagged.
Incoming packets are received untagged for the port default VLAN (PVID), all
other packets are tagged.
Priority Override
VLAN priority code point of incoming packets can be overwritten with the VLAN
specific priority defined in the VLAN filter.
Voice VLAN
VLAN ID used by LLDP/CDP to assign VLAN to connected VoIP-phone.
RSTP VLAN
VLAN ID used by Spanning Tree instance for BPDU tagging.
Unauthorized VLAN
VLAN ID assigned by Port Based Access Control to unauthorized ports
(guest VLAN).
Management VLAN
VLAN ID used by the management agent (device internal port).
Standard
IEEE Std. 802.1D, IEEE Std. 802.1Q, IEEE Std. 802.1p
Quality of Service (QoS)
Priority Queues
4 priority queues per port.
Prioritization
Scheme
Strict priority (higher priority always first) or weighted fair queuing (8:4:2:1
highest to lowest).
Layer1 Priority
Static priority queue can be assigned for each port.
Layer2 Priority
Incoming packets are forwarded according to the priority code point in their
VLAN tag. The 8 VLAN priority code points can be individually mapped on the 4
priority queues.
Layer3 Priority
Incoming packets are forwarded according to the value of the DiffServ Codepoint
(IPv4) / TrafficClass (IPv6) in their IP header. Maximum 64 code points are
supported. For each code point the corresponding priority queue can be mapped.
Traffic shaping
5 ingress rate shaping buckets per port. Supports rate and priority based rate
shaping
Standard
IEEE Std. 802.1p (VLAN priority code point), RFC 2474/3260 (IPv4 DiffServ/IPv6
Traffic Class)
Spanning Tree Protocol / Ring Protocol
Rapid Spanning
Tree (RSTP)
Automatic detection of loops and redundant network paths. Single STP instance
running in configurable VLAN. Rapid Spanning Tree Protocol (RSTP) backwards
compatible to Spanning Tree standard (STP).
MSTP
Separate STP instances running in configurable VLAN groups.
PVST
RSTP per VLAN for one VLAN
MICROSENS Ring
Protocol
MICROSENS Redundant Ring Protocol with ultra-fast recovery time <50 ms
within MICROSENS Ring topologies.
Multicast Forwarding
IGMP Snooping
Snooping of Internet Group Management Protocol (IGMPv1/v2/v3) for IPv4.
Automatic detection and forwarding of IPv4 multicast-streams. Unregistered
packets can be flooded or blocked. Multicast routers can be detected by
discovery or by query message.
Standard
RFC 4541 (IGMP)
Real Time Clock (RTC)
Function
Internal device clock can be synchronized with external NTP server.
Protocol
Simple Network Time Protocol (NTP)
Standard
RFC 4330 (NTP)
©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch
Page 5/13
Link Layer Discovery Protocol (LLDP)
Function
Advertising identity, capabilities, and neighbors on a connected network
segment.
LLDP-MED
Media Endpoint Discovery for the auto-discovery of LAN policies.
Standard
IEEE Std. 802.1AB (LLDP), ANSI/TIA-1057 (LLDP-MED)
Cisco Discovery Protocol (CDP)
Function
CDP v1, v2 for automatic detection of capabilities of neighbor CDP enabled
devices.
Voice VLAN
Support of Voice VLAN for configuration of connected Cisco VoIP-phone.
Port Access Control
Function
Port-Based Network Access Control with dynamic port VLAN support and fallback
to MAC based authentication methods. Network access is controlled at the port
level. Supports IEEE Std. 802.1X Authentication, RADIUS MAC Authentication,
MAC Locking and forced authorized/unauthorized mode.
Communication
EAPOL, RADIUS
Authentication
Protocols
EAP-MD5, EAP-PEAP (inner protocol: MSCHAPv2), EAP-TLS, EAP-TTLS (inner
protocols: EAP-MD5, EAP-TLS, PAP)
IEEE 802.1X
Authentication
Multiple users can be authenticated using central RADIUS server based on
username/password or certificate.
RADIUS MAC
Authentication
Multiple users can be authenticated using central RADIUS server based on their
MAC addresses.
MAC locking
Multiple users can be authenticated based on their MAC addresses. Authorized
MAC addresses are stored permanently in the device. They can be configured
manually or automatically by locking the first MAC addresses learned on the port.
Dynamic VLAN
RADIUS server can provide user specific VLAN ID using tunnel-attribute in accept
message. Port VLAN is dynamically set accordingly. Unauthorized users may be
placed in an unauthorized VLAN ('guest VLAN') or blocked completely.
IP Address
Detection
The IP address of the connected user is detected via ARP snooping. User IP
address information can be logged using RADIUS accounting function.
Standard
IEEE 802.1X-2004 (Port-Based Network Access Control)
User Login
Function
Implements user based and view based authentication and scope limiting.
Supports unlimited number of user/groups and views (limited by system memory
constrains only). Offers ultimate flexibility with precise access control.
Command Line Interface (CLI)
Function
Intuitive command-set with auto-complete and redo-buffer. Individual console
prompt string, Console inactivity timeout. Supports full scripting and editing of
script files. Supports colour displays. Permits offline configuration as well as
management of an unlimited number of user configuration sets (limited by system
memory constrains only).
Telnet
Telnet via TCP/IP port 23.
Secure Shell (SSH) SSH via TCP/IP port 22. Authentication methods RSA, Diffie-Hellman Key
Exchange. Encryption protocols 3DES-CBC, HMAC-SHA1.
Web Manager
Function
Integrated Web Manager with graphical user interface (GUI) for device
configuration and administration using standard web browser.
Protocol
HTML v4.01,HTTP, HTTPS, Java Script
©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch
Browser
compatibility
Page 6/13
Firefox 4.x, IE 8.x, JavaScript support required.
Simple Network Management Protocol (SNMP)
SNMPv1/v2c
Simple Network Management Protocol v1, v2c (SNMPv1, v2c) to access device
information stored in Management Information Base (MIB). Security provided by
community strings for Set/Get commands and optionally by G6 login scheme.
Traps
(SNMPv1/v2c)
Traps, Notifications sent to unlimited number of independently configurable
receiver destinations (limited by system memory constrains only). Sending of
message is triggered by internal device status change events.
Event triggers can be configured individually per destination. Test function to
trigger Trap/Notification for simplified configuration check (Web Manager and CLI
only).
SNMPv3
Simple Network Management Protocol v3 (SNMPv3) for secure access to device
information stored in Management Information Base (MIB). SNMPv3 supports data
encryption, User-based Security Model (USM) and View-based Access Control
Model (VACM).
Traps (SNMPv3)
Trap/Notification, InformRequest, Response sent to independently configurable
receivers. Sending of message is triggered by internal device status change
events. Informs provide secured messaging by requiring response message Event
triggers can be configured individually per receiver.
MIBs
MIB-2, Enterprise-MIB (MICROSENS G6 MIB). File can be downloaded from the
integrated Web Manager.
Standard
RFC 1155/1156/1157 (SNMPv1), RFC 1901/1905/1906 (SNMPv2), RFC
3411/3412/3584 (SNMPv3), RFC 2574/3414 (USM), RFC 2575/3415 (VACM)
RADIUS Client
Function
RADIUS client via UDP/IP ports 1812 (access), 1813 (accounting) for Remote
Authentication Dial In User Service (RADIUS) server for authorizing user access
and logging of user accounting information.
Redundancy
In case of a response timeout, the next RADIUS server is requested.
Standard
RFC 2865 (RADIUS), RFC 2866 (Accounting), RFC 2868 (Tunnel Attributes)
Files
Configuration
File transfers may be used to upgrade the software or to load configuration files.
The unit supports TFTP, FTP, SFTP, HTTP, HTTPS transfer protocols. Additionally
files may be loaded via DHCP directives.
Firmware Update
Software download can be complete or incremental. Individual modules may be
upgraded, normally without influencing service. Flexible system permits
customized upgrade files if required.
Syslog Client
Function
Syslog messages are triggered by system events and can be send to unlimited
number of Syslog servers (limited by system memory constrains only).
Standard
RFC 5424
Event Manager
Function
Mapping of device status changes (Triggers) to actions e.g. sending out SNMP
trap, Syslog message etc.
Customizable
events
Event severity and alert level freely configurable. Event text strings may be
customized via user interface with developer rights.
Traps and Syslog
Unlimited number of trap and/or Syslog receivers. Event may be filtered
individually on a group level.
©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch
Page 7/13
IEEE / RFC Standards
RFC Standards
RFC 791
IPv4
RFC 792
ICMP
RFC 826
ARP
RFC 1155
SNMPv1
RFC 1156
SNMPv1
RFC 1157
SNMPv1
RFC 1901
SNMPv2c
RFC 1905
SNMPv2
RFC 1906
SNMPv2
RFC 2131
DHCP
RFC 2460
IPv6
RFC 2461
IPv6 Neighbour Discovery
RFC 2462
IPv6 Auto Configuration
RFC 2463
ICMPv6
RFC 2464
IPv6
RFC 2474
IPv4 DiffServ
RFC 2574
USM
RFC 2575
VACM
RFC 2865
RADIUS
RFC 2866
Accounting
RFC 2868
Tunnel Attributes
RFC 3260
IPv6 DiffServ
RFC 3315
DHCPv6
RFC 3411
SNMPv3
RFC 3412
SNMPv3
RFC 3414
USM
RFC 3415
VACM
RFC 3484
IPv6
RFC 3513
IPv6
RFC 3584
SNMPv3
RFC 3810
MLD
RFC 4330
NTP
RFC 4541
IGMP Snooping
RFC 4604
MLD
RFC 5424
Syslog
IEEE Standards
802.1D-2004
(Rapid) Spanning Tree
802.1Q-2005
Multiple Spanning Tree
802.1p
QoS
802.1Q
VLAN
802.1X
Network Access Control
802.1AB
LLDP
802.3i
10Base-T
802.3u
100Base-TX
802.3x
Full duplex and flow control
802.3z
1000Base-X
802.3ab
1000Base-T
802.3af
Power-over-Ethernet
802.3at
Power-over-Ethernet (PoE+)
802.3az
Energy-Efficient Ethernet
Interfaces
©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch
Page 8/13
Technical Specifications
Switch
LED displays
Type
Gigabit Ethernet Switch
Layer 2+, IEEE 802.3 compliant
Number
Device
Port
Performance
Store-and-forward
Full wire-speed, non-blocking
on all ports
LED-modes
MAC addresses
8.192 addresses, automatic
learning and aging
Dynamic
Static
Quiet
Dark
L-show
Jumbo Frames
max. 10.240 Bytes
Ethernet
Gigabit Ethernet, Triple Speed
RJ-45 port, shielded
Cable type
Twisted-Pair cable, Category
5e, impedance 100 Ohm, length
max. 100 m
Flow Control
Pause Frames (IEEE 802.3x),
configurable
Pin out
Auto MDI/MDI-X, Auto Polarity
Power-overEthernet
Power Sourcing Equipment
(PSE) IEEE 802.3af/at
Class 0-4, max. 15 W / 30 W
off
Link at port.
Flashing at data traffic
Port blocked
(via protocol)
Port Access Control
rejected
no link
green
yellow
red
off
PoE
PoE
PoE
PoE
red
Type
Connector
green
yellow
25
10/100/1000Base-T
Standard-mode
Standard without flash
Only ON- and Sys-LED
all LEDs off
permanent LED test
Port LEDs (integrated in RJ-45)
Twisted-Pair Ports
Number
10 LEDs
2 LEDs per port
PoE
power active
not active
failure
deactivated
Device LEDs (central)
System 1
off
System activities
(Firmware update)
Normal operation
System 2
off
Normal operation
Power 1/2
green
yellow
Power supply 1/2 OK
Input voltage too
low/missing
Ring 1/2
green
yellow
red
off
Ring
Ring
Ring
Ring
Fiber Ports (SFP slots)
active
1/2 normal
backup active
backup failure
deactivated
Number
8
Signal in 1/2
Type
Gigabit Ethernet
Dual Speed SFP
100/1000Base-X, support of
SFP digital diagnostics function
green
red
off
activated, no signal
S1/S2 activated, alarm
inactive
Signal out 1/2
green
red
off
activated, no signal
S1/S2 activated, alarm
inactive
Connector
LC (SFP transceiver)
Multimode
(MS100200DX)
Multimode, 62.5/125µm (280
m) or 50/125 µm (550 m)
850nm wavelength
-4..-9.5 dBm output power
-18 dBm sensitivity
0 dBm saturation
Single Mode
(MS100210DX)
Single Mode, 9/125 µm (10 km)
1310 nm wavelength
-3..-9,5 dBm output power
-20 dBm sensitivity
-3 dBm saturation
Flow Control
Pause Frames (IEEE 802.3x),
configurable
Control Panel
Reset button
Reset of the switch, new upload
of the latest stored
configuration
(direct hardware function)
Factory button
Request of the IP configuration
for management, reset back to
factory default settings
©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch
Page 9/13
Technical Specifications (continued)
Power Supply
Standards
Input
24..57 VDC (54 VDC typ.)
Connectors
2x 3 pin screw connector
Power Supply for PoE / PoE+
Operation
Input
44..57 VDC
PoE: 48 VDC typ.
PoE+: 54 VDC typ.
CE
2004/108/EC (EMV)
2006/95/EG (Low voltage)
Security
EN 60950-1:2011-01
Emitted
interference
EN 55022:2011-12
Immunity
EN 55024:2011-09
Delivery / Contents
Standard Packaging
Environmental Conditions
Temperature
Operation
Storage
-40..+75 °C
-40..+85 °C
Humidity
10..90%, non condensing
Package unit
1 pcs.
Contents
1x Hardened 19” switch
1x SD memory card
(separate article number)
2x power supply
2x I/O connector
1x Short manual
1x Set stickers with symbols
©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch
Page 10/13
Memory Card
SD Memory Card
The SD memory card is used for the
permanent storage of configuration,
script and firmware files. With this
memory card it is possible to transfer a
configuration to a new device in case of
a device failure.
 Change of memory card transfers the
complete device status
Optional it is possible to write an own
MAC address to the SD memory card.
This MAC address has priority compared
to the MAC address in the switch. This
allows having an exact clone of the
device by swapping the memory card.
 Industrial grade– long term stability
 Firmware update by memory card
exchange possible
 Fault tolerant journaling file system
 Encrypted system as security option
 Only MICROSENS memory cards have
to be used. Only with this the long
term stability over the complete
temperature range can be
guaranteed.
Alarm Contacts
Galvanic isolated contacts (2x)
Galvanic isolated digital inputs (2x)
The potential free output contacts (I/O
out) allows to control external signalling
devices to show the alarm and operation
status.
The potential free input contacts (I/O in)
allow the direct monitoring of external
systems, e.g. a rack or door monitoring
system.

Relay contact, maximum load
57 V/1 A

Isolation voltage to the device
1,500 VDC

Normally open or normally closed
contact possible

The signal status is indicated by an
LED

Attention: Not suitable for the direct
connection of 230 V AC devices!
 2x galvanic isolated, digital input
 Internal optocoupler, Input voltage 12
to 57 V DC
 Isolation voltage 1,500 VDC
 Status monitored via management
©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch
Page 11/13
Gigabit Ethernet Ports
Gigabit Ethernet Ports (RJ-45)
16x Local Ports, PSE (RJ-45)
All Gigabit Ethernet ports are for the
connection of 10, 100 or 1000 Mbps
segments via twisted pair cables with RJ45 connectors.
These ports additional include PoE+
Power Sourcing Equipment (PSE)
functionality. With this the switch can
supply the connected end devices with
electrical power. This is often used for
VoIP-telephones, IP-cameras and WLANAccess Points
The integrated auto negotiation and auto
crossover functions automatically ensure
the best connection method to the end
devices.
1x Local Port, PD (RJ-45)
8x Dual Media Ports (RJ-45/SFP)
This port additional includes a PoE+
powered device (PD) input. Via this port
the switch can be supplied with electrical
power. The power which is not required
by the switch itself can be supplied to
the end devices via its PoE+ ports.
These ports can be optionally used with
twisted pair or fiber cables. For the use
of a fiber cable a suitable SFP must be
plugged into the switch.
The selection of the used media (twisted
pair or fiber) can be made by the
management.
©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch
Page 12/13
Order Information
Description
Article No.:
Ruggedized 19” Gigabit Ethernet Switch with PoE+
Ruggedized 19" Gigabit Ethernet Switch,
16x 10/100/1000T PoE+ (PSE), 1x 10/100/1000T,
8x Dual Media Ports: 100/1000X SFP-Slot or
10/100/1000T,
Serial Port, USB Port, SD Memory Card Slot, I/O: 2x in,
2x out, 2x power input 24..57 VDC
MS400890MX
Memory Cards for Ruggedized 19” Gigabit Switch
SD memory card 4 GB for MICROSENS PL-Switches,
Extended temperature range -25°C up to +85°C
MS140890X-4GB
SD memory card 4 GB for MICROSENS PL-Switches,
Extended temperature range -25°C up to +85°C,
With own MAC address
MS140890X-4GB-M
SD memory card 4 GB for MICROSENS PL-Switches,
Extended temperature range -25°C up to +85°C,
With individual switch configuration according to
customer specifications
MS140890X-4GB-C
SD memory card 4 GB for MICROSENS PL-Switches,
Extended temperature range -25°C up to +85°C,
With individual switch configuration according to
customer specifications and own MAC address
MS140890X-4GB-MC
©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch
Page 13/13
Accessories
Description
Article No.:
SFP Transceiver (Fast Ethernet & WDM on request)
SFP Transceiver, Gigabit Ethernet, Digital Diagnostic
850 nm Multimode, 1000Base-SX, LC duplex
Extended temperature range -25°C up to +85°C
MS100200DX
SFP Transceiver, Gigabit Ethernet, Digital Diagnostic
1310 nm Monomode, 1000Base-LX, LC duplex
Extended temperature range -25°C up to +85°C
MS100210DX
Network Management
NMP Professional – Network Management Platform
Software incl. one year update license
MS200160-1
NMP Professional – additional update license for n years
MS200161-n
NMP Standard– Network Management Platform
Software incl. one year update license
MS200162-1
NMP Standard – additional update license for n years
MS200163-n
NMP Server – Network Management Platform
Software incl. one year update license and 5 clients
MS200164-1
NMP Server – additional update license for n years
MS200165-n
NMP Server – additional client access licenses for n
clients
MS200166-Cn
External Power Supplies for industrial use 24 VDC
DIN Rail Power Supply 24 Watt 24 VDC / 1.0 A,
Wide input range 85-264 VAC, 85…375 VDC
DIN Rail Power Supply 60 Watt 24VDC / 2.5 A,
Adjustment range 21..29VDC
Wide input range 90-264VAC, 85..200VDC
for extended temperature range -40..+75°C
MS700420
MS700482-24B
External Power Supplies for industrial use with PoE / PoE+ 44..57VDC
DIN Rail Power Supply 60 Watt 48 VDC / 1.25 A,
Adjustment range 48..56VDC
Wide input range 85-264 VAC
MS700430
DIN Rail Power Supplies 192 Watt 48 VDC / 4 A,
Adjustment range 48..56VDC
Wide input range 85-264 VAC
MS700467
DIN Rail Power Supply 60 Watt 48 VDC / 1.25 A,
Adjustment range 41..58VDC
Wide input range 90-264VAC, 85..200VDC
For extended temperature range -40..+75°C
MS700482-48B
This document in whole or in part may not be duplicated, reproduced, stored or retransmitted without prior written permission of MICROSENS GmbH
& Co. KG. All information in this document is provided ‘as is’ and subject to change without notice. MICROSENS GmbH & Co. KG disclaims any
liability for the correctness, completeness or quality of the information provided, fitness for a particular purpose or consecutive damage.
MICROSENS is a trademark of MICROSENS GmbH & Co. KG. Any product names mentioned herein may be trademarks and/or registered trademarks
of their respective companies. mr/hb/tk/aku/dh MS400890MX_19inch_switch_DAT_EN_v0.0.2.docx
©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Download