Data Sheet Ruggedized 19” Gigabit Ethernet Switch with Ring Recovery and PoE+ Picture Overview The new hardened 19” switch from MICROSENS, offer maximum performance and flexibility in smallest spaces. Robust and designed for greatest reliability and shortest recovery times, the hardened MICROSENS switch family has become the first-choice solution for Industrial Ethernet. The hardware of the hardened 19” switch is designed today for future functions, which are easy to activate with firmware upgrades. This is facilitated by the latest highperformance switching chipsets in combination with a powerful ARM processor. As an established, stable operating system, Linux offers a solid foundation for an intelligent, open and long-term reliable platform. Highlights Highest Gigabit performance with smallest dimensions Industrial design for maximum reliability in harsh environments 25 Gigabit (8 of them with fiber) ports on only 1U in 19” racks Optimised architecture for increased performance with parallel ring topology PoE+ (max. 30 W per port) integrated Modular SD-card for firmware and configuration Flexible firmware architecture for simple software upgrades Redundant power inputs ©2014_MICROSENS GmbH & Co. KG_Küferstr. 16_59067 Hamm/Germany_www.microsens.com Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch Page 2/13 Specifications Gigabit Ethernet Switch Power-over-Ethernet PoE/PoE+ Fanless Gigabit Ethernet Switch IEEE 802.3af PoE (max. 15 W/Port), power supply with typ. 48 VDC Low power consumption switchchipset, Energy-Efficient Ethernet Layer-2+ store-and-forward Max. 8.192 MAC-addresses, automatic Learning and aging Jumbo-Frames (max. 10,240 Bytes) Energy-Efficient Ethernet EEE according to IEEE 802.3az Reduced power consumption for each RJ-45 port up to 80% depending on the actual requirement Network Management Supports all common management standards High Performance 800 MHz ARM CPU Linux operating system with fast system boot (approx. 20 seconds) Web Manager (HTTP/HTTPS) Telnet/SSH/Console, incl. standardcommands (ping etc.) SNMP v1/v2c/v3 with View-based Access Control Model (VACM) and User-based Security Model (USM) Central management platform (NMP Professional / NMP Server) IEEE 802.3at PoE+ (max. 30 W/Port), power supply with typ. 54 VDC 16x 10/100/1000Base-T, PoE+ (PSE) 1x 10/100/1000Base-T, PoE+ (PD) Connectors (Base-Switch) Up-/Downlinks (Dual Media-Ports) 8x SFP-Slot 100/1000Base-X 8x 10/100/1000Base-T (RJ-45) Local Ports 17x 10/100/1000Base-T (RJ-45) Auto-Negotiation Auto MDI/MDI-X function for the use of uniform patch cables Power Supply 3-pin screw pluggable connector for solid or litz wires RS-232 Console Port Serial terminal port for CLI access (outband management) USB Extension Port For optional accessories Alarm Contacts / I/O-Ports Potential free digital input/output ports 2x output (relay) IPv4/IPv6 Dual Stack 2x input (optocoupler) Integrated CLI scripting for the automation of routine processes Mounting Firmware-, Script- and configuration files can be loaded, stored and executed direct from the switch Mounting into 19” racks requiring 1U space Incremental firmware updates possible Modular SD memory card for the configuration, CLI scripts, firmware ©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch Page 3/13 Feature overview network management IP Stack Dual Stack Parallel handling of IPv4 and IPv6 protocol. IPv4 Stack Internet Protocol v4 handling with support of IPv4, ARP, DHCP, ICMP. RFC 791 (IPv4), RFC 826 (ARP), RFC 792 (ICMP), RFC 2131 (DHCP) IPv6 Stack Internet Protocol v6 handling with support of IPv6, DHCPv6, ICMPv6, NDP. RFC 2460/2464/3484/3513 (IPv6), RFC 2462 (Address Configuration), RFC 2463 (ICMPv6), RFC 2461 (Neighbor Discovery Protocol), RFC 3315 (DHCPv6) Port Control Administration Port disable, Individual port alias Ethernet Copper Auto-Negotiation, speed, duplex mode, flow-control, Auto MDI/MDI-X Ethernet Fiber / SFP Speed, duplex mode, flow-control Green IT Latest chip technology supports Energy-Efficient Ethernet (EEE) according to IEEE Std. 802.3az. Power-over-Ethernet (PoE) Function Sourcing of power to connected devices via standard network Twisted-Pair cable 802.3at mode PoE+ voltage is turned on only after powered device (PD) is detected and classified on port. Output voltage and power is monitored. Port power is shut down if limits are exceeded. 802.3af mode PoE voltage is turned on only after powered device (PD) is detected and classified on port. Output voltage and power is monitored. Port power is shut down if limits are exceeded. Power Management Power limit can be defined per port and per total device. Additionally the class of the powered device (PD) can be limited per port. Standards IEEE Std. 802.3af (Data Terminal Equipment Power via Media Dependent Interface), IEEE Std. 802.3at (Data Terminal Equipment Power via Media Dependent Interface). Switch Functions Port Monitor Monitor port for the connection of a network protocol analyzer. Traffic of the port to be analyzed is copied to the monitor port. RMON counters 17 Integrated counters for detailed traffic analysis and network trouble shooting. MAC Table Access to table of MAC addresses learned by the switch. Can be filtered per port, VLAN address type and entry type (dynamic/static). Virtual LANs (VLANs) Function Logical structuring of physical networks by adding a Virtual LAN ID (VID) to each Ethernet packet. Incoming packets are filtered and forwarded according to their VID. Each port can be configured for Access, Hybrid or Trunk VLAN processing mode. Independent VLANs out of the full range of 1 to 4095 can be filtered per device. Access Mode For the connection of non-VLAN capable end devices (e.g. PCs). Outgoing packets are sent untagged. Incoming packets are tagged with the port default VLAN ID (PVID). Trunk Mode For the interconnection of VLAN capable switches. Outgoing packets are always sent tagged. Incoming packets are received tagged. Incoming packets without VLAN tag are tagged with the port default VLAN ID (PVID). ©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch Page 4/13 Hybrid Mode For the connection of VLAN capable and non-VLAN capable devices on the same port (e.g. VoIP-phone (tagged) and PC (untagged)). Outgoing packets are sent tagged, except packets for the port default VLAN ID (PVID), which are untagged. Incoming packets are received untagged for the port default VLAN (PVID), all other packets are tagged. Priority Override VLAN priority code point of incoming packets can be overwritten with the VLAN specific priority defined in the VLAN filter. Voice VLAN VLAN ID used by LLDP/CDP to assign VLAN to connected VoIP-phone. RSTP VLAN VLAN ID used by Spanning Tree instance for BPDU tagging. Unauthorized VLAN VLAN ID assigned by Port Based Access Control to unauthorized ports (guest VLAN). Management VLAN VLAN ID used by the management agent (device internal port). Standard IEEE Std. 802.1D, IEEE Std. 802.1Q, IEEE Std. 802.1p Quality of Service (QoS) Priority Queues 4 priority queues per port. Prioritization Scheme Strict priority (higher priority always first) or weighted fair queuing (8:4:2:1 highest to lowest). Layer1 Priority Static priority queue can be assigned for each port. Layer2 Priority Incoming packets are forwarded according to the priority code point in their VLAN tag. The 8 VLAN priority code points can be individually mapped on the 4 priority queues. Layer3 Priority Incoming packets are forwarded according to the value of the DiffServ Codepoint (IPv4) / TrafficClass (IPv6) in their IP header. Maximum 64 code points are supported. For each code point the corresponding priority queue can be mapped. Traffic shaping 5 ingress rate shaping buckets per port. Supports rate and priority based rate shaping Standard IEEE Std. 802.1p (VLAN priority code point), RFC 2474/3260 (IPv4 DiffServ/IPv6 Traffic Class) Spanning Tree Protocol / Ring Protocol Rapid Spanning Tree (RSTP) Automatic detection of loops and redundant network paths. Single STP instance running in configurable VLAN. Rapid Spanning Tree Protocol (RSTP) backwards compatible to Spanning Tree standard (STP). MSTP Separate STP instances running in configurable VLAN groups. PVST RSTP per VLAN for one VLAN MICROSENS Ring Protocol MICROSENS Redundant Ring Protocol with ultra-fast recovery time <50 ms within MICROSENS Ring topologies. Multicast Forwarding IGMP Snooping Snooping of Internet Group Management Protocol (IGMPv1/v2/v3) for IPv4. Automatic detection and forwarding of IPv4 multicast-streams. Unregistered packets can be flooded or blocked. Multicast routers can be detected by discovery or by query message. Standard RFC 4541 (IGMP) Real Time Clock (RTC) Function Internal device clock can be synchronized with external NTP server. Protocol Simple Network Time Protocol (NTP) Standard RFC 4330 (NTP) ©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch Page 5/13 Link Layer Discovery Protocol (LLDP) Function Advertising identity, capabilities, and neighbors on a connected network segment. LLDP-MED Media Endpoint Discovery for the auto-discovery of LAN policies. Standard IEEE Std. 802.1AB (LLDP), ANSI/TIA-1057 (LLDP-MED) Cisco Discovery Protocol (CDP) Function CDP v1, v2 for automatic detection of capabilities of neighbor CDP enabled devices. Voice VLAN Support of Voice VLAN for configuration of connected Cisco VoIP-phone. Port Access Control Function Port-Based Network Access Control with dynamic port VLAN support and fallback to MAC based authentication methods. Network access is controlled at the port level. Supports IEEE Std. 802.1X Authentication, RADIUS MAC Authentication, MAC Locking and forced authorized/unauthorized mode. Communication EAPOL, RADIUS Authentication Protocols EAP-MD5, EAP-PEAP (inner protocol: MSCHAPv2), EAP-TLS, EAP-TTLS (inner protocols: EAP-MD5, EAP-TLS, PAP) IEEE 802.1X Authentication Multiple users can be authenticated using central RADIUS server based on username/password or certificate. RADIUS MAC Authentication Multiple users can be authenticated using central RADIUS server based on their MAC addresses. MAC locking Multiple users can be authenticated based on their MAC addresses. Authorized MAC addresses are stored permanently in the device. They can be configured manually or automatically by locking the first MAC addresses learned on the port. Dynamic VLAN RADIUS server can provide user specific VLAN ID using tunnel-attribute in accept message. Port VLAN is dynamically set accordingly. Unauthorized users may be placed in an unauthorized VLAN ('guest VLAN') or blocked completely. IP Address Detection The IP address of the connected user is detected via ARP snooping. User IP address information can be logged using RADIUS accounting function. Standard IEEE 802.1X-2004 (Port-Based Network Access Control) User Login Function Implements user based and view based authentication and scope limiting. Supports unlimited number of user/groups and views (limited by system memory constrains only). Offers ultimate flexibility with precise access control. Command Line Interface (CLI) Function Intuitive command-set with auto-complete and redo-buffer. Individual console prompt string, Console inactivity timeout. Supports full scripting and editing of script files. Supports colour displays. Permits offline configuration as well as management of an unlimited number of user configuration sets (limited by system memory constrains only). Telnet Telnet via TCP/IP port 23. Secure Shell (SSH) SSH via TCP/IP port 22. Authentication methods RSA, Diffie-Hellman Key Exchange. Encryption protocols 3DES-CBC, HMAC-SHA1. Web Manager Function Integrated Web Manager with graphical user interface (GUI) for device configuration and administration using standard web browser. Protocol HTML v4.01,HTTP, HTTPS, Java Script ©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch Browser compatibility Page 6/13 Firefox 4.x, IE 8.x, JavaScript support required. Simple Network Management Protocol (SNMP) SNMPv1/v2c Simple Network Management Protocol v1, v2c (SNMPv1, v2c) to access device information stored in Management Information Base (MIB). Security provided by community strings for Set/Get commands and optionally by G6 login scheme. Traps (SNMPv1/v2c) Traps, Notifications sent to unlimited number of independently configurable receiver destinations (limited by system memory constrains only). Sending of message is triggered by internal device status change events. Event triggers can be configured individually per destination. Test function to trigger Trap/Notification for simplified configuration check (Web Manager and CLI only). SNMPv3 Simple Network Management Protocol v3 (SNMPv3) for secure access to device information stored in Management Information Base (MIB). SNMPv3 supports data encryption, User-based Security Model (USM) and View-based Access Control Model (VACM). Traps (SNMPv3) Trap/Notification, InformRequest, Response sent to independently configurable receivers. Sending of message is triggered by internal device status change events. Informs provide secured messaging by requiring response message Event triggers can be configured individually per receiver. MIBs MIB-2, Enterprise-MIB (MICROSENS G6 MIB). File can be downloaded from the integrated Web Manager. Standard RFC 1155/1156/1157 (SNMPv1), RFC 1901/1905/1906 (SNMPv2), RFC 3411/3412/3584 (SNMPv3), RFC 2574/3414 (USM), RFC 2575/3415 (VACM) RADIUS Client Function RADIUS client via UDP/IP ports 1812 (access), 1813 (accounting) for Remote Authentication Dial In User Service (RADIUS) server for authorizing user access and logging of user accounting information. Redundancy In case of a response timeout, the next RADIUS server is requested. Standard RFC 2865 (RADIUS), RFC 2866 (Accounting), RFC 2868 (Tunnel Attributes) Files Configuration File transfers may be used to upgrade the software or to load configuration files. The unit supports TFTP, FTP, SFTP, HTTP, HTTPS transfer protocols. Additionally files may be loaded via DHCP directives. Firmware Update Software download can be complete or incremental. Individual modules may be upgraded, normally without influencing service. Flexible system permits customized upgrade files if required. Syslog Client Function Syslog messages are triggered by system events and can be send to unlimited number of Syslog servers (limited by system memory constrains only). Standard RFC 5424 Event Manager Function Mapping of device status changes (Triggers) to actions e.g. sending out SNMP trap, Syslog message etc. Customizable events Event severity and alert level freely configurable. Event text strings may be customized via user interface with developer rights. Traps and Syslog Unlimited number of trap and/or Syslog receivers. Event may be filtered individually on a group level. ©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch Page 7/13 IEEE / RFC Standards RFC Standards RFC 791 IPv4 RFC 792 ICMP RFC 826 ARP RFC 1155 SNMPv1 RFC 1156 SNMPv1 RFC 1157 SNMPv1 RFC 1901 SNMPv2c RFC 1905 SNMPv2 RFC 1906 SNMPv2 RFC 2131 DHCP RFC 2460 IPv6 RFC 2461 IPv6 Neighbour Discovery RFC 2462 IPv6 Auto Configuration RFC 2463 ICMPv6 RFC 2464 IPv6 RFC 2474 IPv4 DiffServ RFC 2574 USM RFC 2575 VACM RFC 2865 RADIUS RFC 2866 Accounting RFC 2868 Tunnel Attributes RFC 3260 IPv6 DiffServ RFC 3315 DHCPv6 RFC 3411 SNMPv3 RFC 3412 SNMPv3 RFC 3414 USM RFC 3415 VACM RFC 3484 IPv6 RFC 3513 IPv6 RFC 3584 SNMPv3 RFC 3810 MLD RFC 4330 NTP RFC 4541 IGMP Snooping RFC 4604 MLD RFC 5424 Syslog IEEE Standards 802.1D-2004 (Rapid) Spanning Tree 802.1Q-2005 Multiple Spanning Tree 802.1p QoS 802.1Q VLAN 802.1X Network Access Control 802.1AB LLDP 802.3i 10Base-T 802.3u 100Base-TX 802.3x Full duplex and flow control 802.3z 1000Base-X 802.3ab 1000Base-T 802.3af Power-over-Ethernet 802.3at Power-over-Ethernet (PoE+) 802.3az Energy-Efficient Ethernet Interfaces ©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch Page 8/13 Technical Specifications Switch LED displays Type Gigabit Ethernet Switch Layer 2+, IEEE 802.3 compliant Number Device Port Performance Store-and-forward Full wire-speed, non-blocking on all ports LED-modes MAC addresses 8.192 addresses, automatic learning and aging Dynamic Static Quiet Dark L-show Jumbo Frames max. 10.240 Bytes Ethernet Gigabit Ethernet, Triple Speed RJ-45 port, shielded Cable type Twisted-Pair cable, Category 5e, impedance 100 Ohm, length max. 100 m Flow Control Pause Frames (IEEE 802.3x), configurable Pin out Auto MDI/MDI-X, Auto Polarity Power-overEthernet Power Sourcing Equipment (PSE) IEEE 802.3af/at Class 0-4, max. 15 W / 30 W off Link at port. Flashing at data traffic Port blocked (via protocol) Port Access Control rejected no link green yellow red off PoE PoE PoE PoE red Type Connector green yellow 25 10/100/1000Base-T Standard-mode Standard without flash Only ON- and Sys-LED all LEDs off permanent LED test Port LEDs (integrated in RJ-45) Twisted-Pair Ports Number 10 LEDs 2 LEDs per port PoE power active not active failure deactivated Device LEDs (central) System 1 off System activities (Firmware update) Normal operation System 2 off Normal operation Power 1/2 green yellow Power supply 1/2 OK Input voltage too low/missing Ring 1/2 green yellow red off Ring Ring Ring Ring Fiber Ports (SFP slots) active 1/2 normal backup active backup failure deactivated Number 8 Signal in 1/2 Type Gigabit Ethernet Dual Speed SFP 100/1000Base-X, support of SFP digital diagnostics function green red off activated, no signal S1/S2 activated, alarm inactive Signal out 1/2 green red off activated, no signal S1/S2 activated, alarm inactive Connector LC (SFP transceiver) Multimode (MS100200DX) Multimode, 62.5/125µm (280 m) or 50/125 µm (550 m) 850nm wavelength -4..-9.5 dBm output power -18 dBm sensitivity 0 dBm saturation Single Mode (MS100210DX) Single Mode, 9/125 µm (10 km) 1310 nm wavelength -3..-9,5 dBm output power -20 dBm sensitivity -3 dBm saturation Flow Control Pause Frames (IEEE 802.3x), configurable Control Panel Reset button Reset of the switch, new upload of the latest stored configuration (direct hardware function) Factory button Request of the IP configuration for management, reset back to factory default settings ©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch Page 9/13 Technical Specifications (continued) Power Supply Standards Input 24..57 VDC (54 VDC typ.) Connectors 2x 3 pin screw connector Power Supply for PoE / PoE+ Operation Input 44..57 VDC PoE: 48 VDC typ. PoE+: 54 VDC typ. CE 2004/108/EC (EMV) 2006/95/EG (Low voltage) Security EN 60950-1:2011-01 Emitted interference EN 55022:2011-12 Immunity EN 55024:2011-09 Delivery / Contents Standard Packaging Environmental Conditions Temperature Operation Storage -40..+75 °C -40..+85 °C Humidity 10..90%, non condensing Package unit 1 pcs. Contents 1x Hardened 19” switch 1x SD memory card (separate article number) 2x power supply 2x I/O connector 1x Short manual 1x Set stickers with symbols ©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch Page 10/13 Memory Card SD Memory Card The SD memory card is used for the permanent storage of configuration, script and firmware files. With this memory card it is possible to transfer a configuration to a new device in case of a device failure. Change of memory card transfers the complete device status Optional it is possible to write an own MAC address to the SD memory card. This MAC address has priority compared to the MAC address in the switch. This allows having an exact clone of the device by swapping the memory card. Industrial grade– long term stability Firmware update by memory card exchange possible Fault tolerant journaling file system Encrypted system as security option Only MICROSENS memory cards have to be used. Only with this the long term stability over the complete temperature range can be guaranteed. Alarm Contacts Galvanic isolated contacts (2x) Galvanic isolated digital inputs (2x) The potential free output contacts (I/O out) allows to control external signalling devices to show the alarm and operation status. The potential free input contacts (I/O in) allow the direct monitoring of external systems, e.g. a rack or door monitoring system. Relay contact, maximum load 57 V/1 A Isolation voltage to the device 1,500 VDC Normally open or normally closed contact possible The signal status is indicated by an LED Attention: Not suitable for the direct connection of 230 V AC devices! 2x galvanic isolated, digital input Internal optocoupler, Input voltage 12 to 57 V DC Isolation voltage 1,500 VDC Status monitored via management ©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch Page 11/13 Gigabit Ethernet Ports Gigabit Ethernet Ports (RJ-45) 16x Local Ports, PSE (RJ-45) All Gigabit Ethernet ports are for the connection of 10, 100 or 1000 Mbps segments via twisted pair cables with RJ45 connectors. These ports additional include PoE+ Power Sourcing Equipment (PSE) functionality. With this the switch can supply the connected end devices with electrical power. This is often used for VoIP-telephones, IP-cameras and WLANAccess Points The integrated auto negotiation and auto crossover functions automatically ensure the best connection method to the end devices. 1x Local Port, PD (RJ-45) 8x Dual Media Ports (RJ-45/SFP) This port additional includes a PoE+ powered device (PD) input. Via this port the switch can be supplied with electrical power. The power which is not required by the switch itself can be supplied to the end devices via its PoE+ ports. These ports can be optionally used with twisted pair or fiber cables. For the use of a fiber cable a suitable SFP must be plugged into the switch. The selection of the used media (twisted pair or fiber) can be made by the management. ©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch Page 12/13 Order Information Description Article No.: Ruggedized 19” Gigabit Ethernet Switch with PoE+ Ruggedized 19" Gigabit Ethernet Switch, 16x 10/100/1000T PoE+ (PSE), 1x 10/100/1000T, 8x Dual Media Ports: 100/1000X SFP-Slot or 10/100/1000T, Serial Port, USB Port, SD Memory Card Slot, I/O: 2x in, 2x out, 2x power input 24..57 VDC MS400890MX Memory Cards for Ruggedized 19” Gigabit Switch SD memory card 4 GB for MICROSENS PL-Switches, Extended temperature range -25°C up to +85°C MS140890X-4GB SD memory card 4 GB for MICROSENS PL-Switches, Extended temperature range -25°C up to +85°C, With own MAC address MS140890X-4GB-M SD memory card 4 GB for MICROSENS PL-Switches, Extended temperature range -25°C up to +85°C, With individual switch configuration according to customer specifications MS140890X-4GB-C SD memory card 4 GB for MICROSENS PL-Switches, Extended temperature range -25°C up to +85°C, With individual switch configuration according to customer specifications and own MAC address MS140890X-4GB-MC ©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com Data Sheet_Ruggedized 19” Gigabit Ethernet Ring-Switch Page 13/13 Accessories Description Article No.: SFP Transceiver (Fast Ethernet & WDM on request) SFP Transceiver, Gigabit Ethernet, Digital Diagnostic 850 nm Multimode, 1000Base-SX, LC duplex Extended temperature range -25°C up to +85°C MS100200DX SFP Transceiver, Gigabit Ethernet, Digital Diagnostic 1310 nm Monomode, 1000Base-LX, LC duplex Extended temperature range -25°C up to +85°C MS100210DX Network Management NMP Professional – Network Management Platform Software incl. one year update license MS200160-1 NMP Professional – additional update license for n years MS200161-n NMP Standard– Network Management Platform Software incl. one year update license MS200162-1 NMP Standard – additional update license for n years MS200163-n NMP Server – Network Management Platform Software incl. one year update license and 5 clients MS200164-1 NMP Server – additional update license for n years MS200165-n NMP Server – additional client access licenses for n clients MS200166-Cn External Power Supplies for industrial use 24 VDC DIN Rail Power Supply 24 Watt 24 VDC / 1.0 A, Wide input range 85-264 VAC, 85…375 VDC DIN Rail Power Supply 60 Watt 24VDC / 2.5 A, Adjustment range 21..29VDC Wide input range 90-264VAC, 85..200VDC for extended temperature range -40..+75°C MS700420 MS700482-24B External Power Supplies for industrial use with PoE / PoE+ 44..57VDC DIN Rail Power Supply 60 Watt 48 VDC / 1.25 A, Adjustment range 48..56VDC Wide input range 85-264 VAC MS700430 DIN Rail Power Supplies 192 Watt 48 VDC / 4 A, Adjustment range 48..56VDC Wide input range 85-264 VAC MS700467 DIN Rail Power Supply 60 Watt 48 VDC / 1.25 A, Adjustment range 41..58VDC Wide input range 90-264VAC, 85..200VDC For extended temperature range -40..+75°C MS700482-48B This document in whole or in part may not be duplicated, reproduced, stored or retransmitted without prior written permission of MICROSENS GmbH & Co. KG. All information in this document is provided ‘as is’ and subject to change without notice. MICROSENS GmbH & Co. KG disclaims any liability for the correctness, completeness or quality of the information provided, fitness for a particular purpose or consecutive damage. MICROSENS is a trademark of MICROSENS GmbH & Co. KG. Any product names mentioned herein may be trademarks and/or registered trademarks of their respective companies. mr/hb/tk/aku/dh MS400890MX_19inch_switch_DAT_EN_v0.0.2.docx ©2014_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com