AC Coupling Small Wind Turbines Off-Grid Original DC Coupled System 48V 4400W Inverter/Charger (I/C) 740ah Battery 2.5kW Wind 2.5kW Tracked PV DC Coupled Pill Box DC Coupled Yurt Ranch Expansion Ranch Expansion Water Pumping for Cattle Operation Bakery & Pico Brewery At Limits of Original System DC Coupled Pill Box DC Coupled Yurt DC Coupled Power House Bakery DC Coupled nd 2 DC Coupled System 48V 8,800W I/C 1,780ah Battery 2.5kW Wind 3.2 kW PV New System otherpower.com Workshop May 2012 Down with the Old/Up with the New The Road to AC Coupling The Need to Combine New and Old System Large AC Loads I/C with Frequency Shifting New to the Market AC Coupling • GTI Latches onto 240VAC-60 Hz Produced from I/C • Loads & Energy Sources are Coupled More Closely • Excess Energy is Pushed Back thru I/C to Battery AC Coupled Pill Box AC Coupled Yurt DC Coupled Power House Bakery DC Coupled AC Coupled AC Coupled Combined AC/DC Coupled System 48V 17,600W I/C 1,780ah Battery 12’ Wind Turbine DC Coupled 12’ Wind Turbine AC Coupled 3.2 kW PV DC Coupled 7.5 kW PV AC Coupled Magnum Energy PAE Inverter/Charger Regulating Strategies Diversion Loads Frequency Shift Monitoring and Controlling Loads Diversion Loads Frequency Shift Frequency Shift to 60.5 Herz @ 4V above Absorb.... GTI's go Offline per UL 1741 Frequency Shift Back to 60.0 ish Herz @ 4V below Absorb.....GTI's Back Online Monitoring and Controlling Loads •Domestic Hot Water Pre-Heat • Radiant in-floor Hot Water Pre-Heat • Well pump for filling Cisterns • Heater for battery vault Too Much Power...Put it to Work System Equipment 2 otherpower 12' Wind Turbines 100V & 48V Stator 16 Trojan IND-6 Batteries 890 Ah 1 Ginlong 3K GT Wind Inverter 3 Ginlong 3K GT Solar Inverter 1 TriStar MPPT Solar Charge Controller 4 Magnum PAE 4400W-48V Inverter/Chargers 17,600W 4 TriStar Diversion Load Controller with 17,280W Load Resistor Heaters AC Coupling Off-Grid Disadvantages • GTI knocked Off-Line when Large Loads Turn on - Extreme Under/Over Voltage - Extreme Under/Over Frequency •Cost?....Maybe AC Coupling Off-Grid Advantages • Increases Turbine Placement Options • Savings on Conductors • Large Loads & Energy Sources are Coupled • Cost?..........Maybe Observations • The need for DC Coupled Wind & Solar to keep the Micro-Grid alive • Higher Resource to Load Conversion • 1741 Five minute Requirement Altered Project Credits Robert’s Electric WindFarmer King Canyon Buffalo otherpower.com Hencey Plumbing Todd Hanley APRS World Roy Rak marc@windfarmer.us