HVJ6-LED 6” ARCHITECTURAL LED RETROFIT DOWNLIGHT HVJ6-LED Catalog Number Type Project Name NE W A Height = 8-1/2” B Trim Aperture = 6-1/8” C Cut-out = 6-3/4” D Trim Outside Dia. = 7-3/8” 1500 INPUT VOLT. INPUT FREQ. INPUT CUR. INPUT POWER THD POWER FACTOR LUMENS 120/277 120/277 120/277 50/60Hz 50/60Hz 50/60Hz 283mA/123mA 180mA/76mA 133mA/57mA 34W(+/-5%) 21W(+/-5%) 16W(+/-5%) <20% <20% <20% >0.9 >0.9 >0.9 1500 1100 800 DESCRIPTION - 6” LED dedicated Architectural Retrofit Downlight with integral LED heat management casting and driver. Available in 800 lumens (16W), 1100 lumens (21W) & 1500 lumens (34W). Lighting is smooth and comfortable while using 25% less energy than the common 26W & 32W CFL downlight. Plus the eco-friendly Maxilume LED system features 70% lumen maintenance at 50,000 hours life, with California Title-24-2008 compliance and Energy Star Rating (pending). Designed to install into an existing downlights mounting frame and convert them into energy efficient LED downlights to save anywhere from 35% up to 75% on energy cost. Fits all downlights with 6-3/4” aperture. Custom size and aperture, LED retrofit and reflectors are available, please consult factory for further details. FEATURES - Greater light output than a 26W & 32W CFL while consuming less than 16W to 34W of power. Maxilume LED luminaires are ideally suited for use in hospitality, health care, commercial, institutions, retail and other architectural applications. PENDING 6 INCH ARCHITECTUR AL LED RETROFIT DO WNLI GHT OPTICS - MAXILUME LED Optilux technology combines unmatched performance with visual comfort. Spun 0.05” thick reflector has been designed to gather the light scattered by the LED chip and shape it into functional beams that minimize brightness and glare, while eliminating lamp image. Proprietary dual level upper and lower reflector design allows for optimum glare control. Elite engineered superior quality, light engine; producing 800 lumens (16W) , 1100 lumens (21W) & 1500 lumens (34W). LED DRIVER/JUNCTION BOX - The LED driver is rated for 50 to 60Hz at 120V /277V input, produces less than 20%THD, and has a power factor between 90% and 100% and is thermally protected for additional safety. MAXILUME’s LED driver is installed on the junction box cover so it may be serviced from below the ceiling. UL Listed for through-branch circuit wiring, provided with four ½” knockouts, one ¾” knockout and four Romex knockouts with true pryout slots and strain clamps. Designed for straight through conduit runs. PERFORMANCE - Operating system delivers 800 lumens (16W), 1100 lumens (21W) & 1500 lumens (34W) with a 4100K color temperature. All MAXILUME LED luminaries are rated at 80+ CRI. All LED luminaries are rated and tested to LM-79 and LM-80 standards by an independent laboratory. MOUNTING - Our retrofit is designed to install into an existing downlights mounting frame and convert them into energy efficient LED downlights. Flex is designed to attach into existing junction box. THERMAL MANAGEMENT SYSTEM - Using a proprietary cooLED Advanced Thermodynamic Design, Die-cast aluminum housing and heat management system are engineered for extremely long life and service period. Heat sink is attached to top of housing. The LED light engine is attached to the die-cast heat sink and is easily replaceable and upgradable. Life tests have shown the MAXILUME light engine output will be maintained at 70% of initial at 50,000 hours of operation. DIMMABLE - The MAXILUME LED system is fully dimmable down to 10% of initial light output with a 0-10 Volt dimmer when ordered with the following options (DIM10-120, DIM10-277). Fixtures can be shipped with a Lutron Hi-lume A series Driver which can be dimmed with Lutron Dimming Systems when ordered with the following options (LUTH-120, LUTH-277). Triac & Electronic Low Voltage dimming driver also available when ordered with the following options (DIMTR-120). Consult Factory for details. OUR WORD - The MAXILUME LED lighting system is warranted for 3 years. As a system, we stand behind the entire MAXILUME product. LISTING c-UL-us listed for Damp location. c-UL-us listed for feed Through Wiring. LM79 / LM80 DIMMING INFORMATION DIMTR (Triac & Electronic Low Voltage Dimming) DIM10 (0-10V Dimming) LUTH (Lutron® Hi-lume® Dimming) HVJ6-LED TYPE 800 LUMENS HVJ6-LED o 16W-DIMTR-120 o 16W-LUTH-120 o 16W-LUTH-277 o 16W-DIM10-120 o 16W-DIM10-277 1100 LUMENS o 21W-LUTH-120 o 21W-LUTH-277 o 21W-DIM10-120 o 21W-DIM10-277 1500 LUMENS OPTICS o 34W-LUTH-120 o FL o 34W-LUTH-277 o 34W-DIM10-120 o 34W-DIM10-277 COLOR o 30K o 35K o 41K EMERGENCY TRIM TYPE o EMG-LED o LED-6101 o LED-6102 o LED-6107 o LED-6109 o LED-6110 o LED-6128 o LED-6123 o o o o o o o LED-6112 LED-6113 LED-6114 LED-6115 LED-6121 LED-6122 LED-6125 REFLECTOR/ RING FINISH o CL-WH o W-WH o CL-SCH o MB-WH o SHZ-SHZ o WT-WH o SHZ-WH DISC o BLUE o RED o GREEN o FROST o AL o BZ o WH Example: HVJ6-LED-21W-DIM10-120-FL-30K-LED-6101-CL-WH 84 • TEL: 1-877-375-5555 • FAX: 1-877-375-3333 WWW.MAXILUME.COM & WWW.IUSEELITELED.COM ALL PRODUCTS ARE U.S. AND FOREIGN PATENT PENDING 6” LED OPTICS EXAMPLE: LED-6102-CL-WH EXAMPLE: LED-6101-CL-WH LED-6101 - REFLECTOR REFLECTOR/ RING FINISH: CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH A= 7-1/8” B= 7-3/8” A= 7-1/8” B= 7-3/8” EXAMPLE: LED-6114-CL-WH LED-6114 - REFLECTOR W/ FROSTED GLASS LENS REFLECTOR/ RING FINISH: CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH LED-6112 - BAFFLE W/ FROSTED GLASS LENS REFLECTOR/ RING FINISH: CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH A= 7-1/2” B= 7-3/8” C= 1” EXAMPLE: LED-6113-CL-WH A= 7-1/2” B= 7-3/8” C= 1” EXAMPLE: LED-6115-CL-WH LED-6115 - REFLECTOR W/ TEMPERED CLEAR GLASS REFLECTOR/ RING FINISH: CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH A= 7-1/8” B= 7-3/8” C= 1” EXAMPLE: LED-6112-CL-WH EXAMPLE: LED-6107-CL-WH LED-6107 - WALL WASH REFLECTOR REFLECTOR/ RING FINISH: CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH LED-6102 - BAFFLE W/ REFLECTOR REFLECTOR/ RING FINISH: CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH LED-6113 - BAFFLE W/ TEMPERED CLEAR GLASS REFLECTOR/ RING FINISH: CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH A= 7-1/2” B= 7-3/8” C= 1” EXAMPLE: LED-6121-CL-WH A= 7-1/2” B= 7-3/8” C= 1” LED-6121 - STARDUST DECO RING GLASS REFLECTOR/ RING FINISH: CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH A= 7-1/8” B= 7-3/8” C= 1-1/4” 6 INCH EXAMPLE: LED-6122-CL-WH EXAMPLE: LED-6123-CL-WH A= 7-1/8” B= 7-3/8” C= 1-1/4” A= 7-1/8” B= 7-3/8” C= 1-1/4” EXAMPLE: LED-6110-CL-WH EXAMPLE: LED-6109-CL-WH LED-6109 - DECO GLASS REFLECTOR REFLECTOR/ RING FINISH: CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH GLASS FINISH: BLUE, RED, GREEN, FROST LED-6123 - PRISM DECO RING GLASS REFLECTOR/ RING FINISH: CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH A= 7-1/8” B= 7-3/8” C= 1-1/4” LED-6110 - DOUBLE RING GLASS REFLECTOR/ RING FINISH: CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH GLASS FINISH: BLUE, RED, GREEN, FROST A= 7-1/8” B= 7-3/8” C= 1-1/2” ALUMINIUM DISC EXAMPLE: LED-6125-CL-WH EXAMPLE: LED-6128-CL-WH-AL LED-6128 - DECO GLASS REFLECTOR WITH ALUMINIUM DISC REFLECTOR FINISH: CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH DISC FINISH: AL, WH, BZ ALL PRODUCTS ARE U.S. AND FOREIGN PATENT PENDING A= 7-1/8” B= 7-3/8” C= 1-1/4” LED-6125 - CENTRAL ETCHED FLOAT GLASS REFLECTOR/ RING FINISH: CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH A= 7-1/8” B= 7-3/8” C= 1-1/4” • TEL: 1-877-375-5555 • FAX: 1-877-375-3333 WWW.MAXILUME.COM & WWW.IUSEELITELED.COM 85 ARCHITECTUR AL LED DOW NLI GHT OPTI CS LED-6122 - EURO DECO RING GLASS REFLECTOR/ RING FINISH: CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH 6” LED PHOTOMETRICS HV6-LED-21W-MVOLT-DIM-FL-30K-LED-6101-SHZ / HVJ(R)6-LED-21W-MVOLT-DIM-FL-30K-LED-6101-SHZ INPUT WATTS: 21 LUMENS: 974 CRI: 85 EFFICACY: 41 LPW CCT: 3000K Candle Power Distribution (Candelas) 90° 80° 424 70° 849 Zonal Lumens Summary Zone 0-300 0-400 0-600 0-900 Lumens 828 886 952 974 Lumens Per Zone Luminance Data (cd/sq.m) %Lamp 85.3 91.3 98.1 100.3 %Fixt 85.03 91 97.8 100 60° Angle In Degrees Average 00 Average 550 Average 900 450 550 650 750 850 3950 2855 1905 1206 314 3950 2855 1905 1206 314 3950 2855 1905 1206 314 50° 1273 40° Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 30° 1697 0° 20° 10° 4’ 6’ 8’ 10’ 12’ 106.09 47.15 26.52 16.97 11.79 4.7’ 7.1’ 9.4’ 11.8’ 14.2’ Distance to Plane Initial Nadir Footcandles Beam Spread ROOM CAVITY RATIO Beam Angle: 61° BEAM DIA. MEASURED AT 10% OF NADIR F.C. TEST NO.: 26606-1 SPACING CRITERIA: 0.8 Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 150 369.64 308.78 57.85 39.46 26.92 14.64 6.19 .9 RC RW 80% 70% 50% 30%10% 70% 70% 50% 30% 10% 50% 50% 30% 10% 30% 50% 30% 10% 10% 50% 30% 10% 0 1 2 3 4 5 6 7 8 9 10 119119119119 114 111 109 107 109 104 100 97 104 98 93 90 99 92 87 83 95 87 82 78 91 83 77 73 87 79 73 69 84 75 70 66 80 72 66 63 77 68 63 60 117117117 117 112 109 107 105 107 103 99 96 102 97 92 89 98 91 86 83 93 86 81 78 90 82 77 73 86 78 73 69 82 74 69 66 79 71 66 62 76 68 63 60 111111 111 105 104 102 99 96 94 94 90 87 89 85 82 85 80 77 81 76 73 77 72 69 73 69 65 70 66 62 67 63 59 107107107 102 100 99 96 94 92 92 89 86 87 84 81 83 79 76 79 75 72 76 72 68 72 68 65 69 65 62 67 62 59 102102102 98 97 96 94 92 90 89 87 85 85 82 80 81 78 76 78 74 72 75 71 68 71 68 65 69 65 62 66 62 59 RC - Ceiling Cavity Reflectance 90° 80° 424 467 70° 849 934 Zonal Lumens Summary Zone 0-300 0-400 0-600 0-900 Lumens 911.26 974.89 1047.92 1071.81 %Fixt 85 91 97.8 100 60° 1273 40° Angle In Degrees Average 00 Average 550 Average 900 450 550 650 750 850 4355 3141 2096 1327 346 4355 3141 2096 1327 346 4355 3141 2096 1327 346 Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 30° 1697 1867 0° 20° 10° 116.7 51.87 29.17 18.67 12.97 4.7’ 7.1’ 9.4’ 11.8’ 14.2’ Distance to Plane Initial Nadir Footcandles Beam Spread BEAM DIA. MEASURED AT 10% OF NADIR F.C. Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 165 406 339.66 63.63 43.41 29.62 16.1 6.81 .99 70% 70% 50% 30% 10% 50% 50% 30% 10% 30% 50% 30% 10% 10% 50% 30% 10% 0 1 2 3 4 5 6 7 8 9 10 119 114 109 104 99 95 91 87 83 80 77 116 111 106 102 97 93 89 86 82 79 76 111 105 99 94 89 84 80 77 73 70 67 106 101 96 91 87 83 79 75 72 69 66 102 98 93 89 85 81 78 74 71 68 66 119 109 100 93 87 82 77 73 69 66 63 119 107 97 89 83 78 73 69 66 62 59 116 109 102 96 91 86 82 78 74 71 68 116 107 99 92 86 81 77 73 69 66 63 116 105 96 88 82 77 73 69 65 62 59 111 103 96 90 85 80 76 72 68 65 62 111 102 94 87 81 77 72 69 65 62 59 106 100 94 88 83 79 75 71 68 65 62 106 99 92 86 81 76 72 68 65 62 59 102 97 91 87 82 78 74 71 67 64 62 90° 80° 424 488 70° 849 976 Zonal Lumens Summary Zone 0-300 0-400 0-600 0-900 Lumens 952.68 1019.54 1095.54 1120.51 %Fixt 85 91 97.8 100 Angle In Degrees Average 00 Average 550 Average 900 450 550 650 750 850 5543 3283 2190 1386 358 5543 3283 2190 1386 358 5543 3283 2190 1386 358 50° 1273 40° Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 30° 1697 1952 0° 20° 10° Beam Angle: 61° 4’ 6’ 8’ 10’ 12’ 122 54.22 30.5 19.52 13.56 4.7’ 7.1’ 9.4’ 11.8’ 14.2’ Distance to Plane Initial Nadir Footcandles Beam Spread BEAM DIA. MEASURED AT 10% OF NADIR F.C. Zone Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 172.5 425.08 355.1 66.52 55.38 30.96 16.83 7.11 1.03 80% 70% 50% 30%10% 70% 70% 50% 30% 10% 50% 50% 30% 10% 30% 50% 30% 10% 10% 50% 30% 10% 0 1 2 3 4 5 6 7 8 9 10 119 114 109 104 99 95 91 87 83 80 77 116 111 106 102 97 93 89 86 82 79 76 111 105 99 94 89 84 80 77 73 70 67 106 101 96 91 87 83 79 75 72 69 66 102 98 93 89 85 81 78 74 71 68 66 119 109 100 93 87 82 77 73 69 66 63 100 94 88 83 78 74 70 67 63 60 58 TEST NO.: 26606-3 SPACING CRITERIA: 0.8 RC RW 119 111 104 98 92 87 82 78 75 71 68 0 1867.14 1764.4 1482.91 820.82 85.58 56.10 32.89 16.17 6.27 .55 0 0% 0% Lumens Per Zone Luminance Data (cd/sq.m) %Lamp 85 91 97.8 100 60° 1464 102 96 90 84 80 75 71 68 65 62 59 0 5 15 25 35 55 55 65 75 85 90 RW - Wall Reflectance HV6-LED-21W-MVOLT-DIM-FL-41K-LED-6101-SHZ / HVJ(R)6-LED-21W-MVOLT-DIM-FL-41K-LED-6101-SHZ INPUT WATTS: 21 LUMENS: 1121 CRI: 85 EFFICACY: 52 LPW CCT: 4100K Candle Power Distribution (Candelas) Candela Tabulation Zone 80% 70% 50% 30%10% 119 111 104 98 92 87 82 78 75 71 68 100 94 88 83 78 74 70 67 64 61 58 TEST NO.: 26606-2 SPACING CRITERIA: 0.8 RC RW RC - Ceiling Cavity Reflectance ROOM CAVITY RATIO LED ARCH ITECTURA L DOW NLI GHT 4’ 6’ 8’ 10’ 12’ ROOM CAVITY RATIO 6 INCH Beam Angle: 61° 0 1679 1604 1348 746 78 51 30 15 6 1 0 0% 0% Lumens Per Zone Luminance Data (cd/sq.m) %Lamp 85 91 97.8 100 50° 1400 0 5 15 25 35 55 55 65 75 85 90 RW - Wall Reflectance HV6-LED-21W-MVOLT-DIM-FL-35K-LED-6101-SHZ / HVJ(R)6-LED-21W-MVOLT-DIM-FL-35K-LED-6101-SHZ INPUT WATTS: 21 LUMENS: 1071 CRI: 85 EFFICACY: 50 LPW CCT: 3500K Candle Power Distribution (Candelas) Candela Tabulation Zone 119 107 97 89 83 78 73 69 66 62 59 RC - Ceiling Cavity Reflectance 116 109 102 96 91 86 82 78 74 71 68 116 107 99 92 86 81 77 73 69 66 63 116 105 96 88 82 77 73 69 65 62 59 111 103 96 90 85 80 76 72 68 65 62 111 102 94 87 81 77 72 69 65 62 59 106 100 94 88 83 79 75 71 68 65 62 106 99 92 86 81 76 72 68 65 62 59 102 97 91 87 82 78 74 71 67 64 62 102 96 90 84 80 75 71 68 65 62 59 Candela Tabulation 0 5 15 25 35 55 55 65 75 85 90 0 1952.01 1844.6 1550.31 858.13 89.47 58.65 34.38 16.9 6.55 .57 0 0% 0% 100 94 88 83 78 74 70 67 63 60 58 RW - Wall Reflectance 88 • TEL: 1-877-375-5555 • FAX: 1-877-375-3333 WWW.MAXILUME.COM & WWW.IUSEELITELED.COM ALL PRODUCTS ARE U.S. AND FOREIGN PATENT PENDING