HVJ6LEDRetrofitDownlightSpecSheet2

advertisement
HVJ6-LED 6” ARCHITECTURAL
LED RETROFIT DOWNLIGHT
HVJ6-LED
Catalog Number
Type
Project Name
NE
W
A Height = 8-1/2”
B Trim Aperture = 6-1/8”
C Cut-out = 6-3/4”
D Trim Outside Dia. = 7-3/8”
1500
INPUT VOLT.
INPUT FREQ.
INPUT CUR.
INPUT POWER
THD
POWER FACTOR
LUMENS
120/277
120/277
120/277
50/60Hz
50/60Hz
50/60Hz
283mA/123mA
180mA/76mA
133mA/57mA
34W(+/-5%)
21W(+/-5%)
16W(+/-5%)
<20%
<20%
<20%
>0.9
>0.9
>0.9
1500
1100
800
DESCRIPTION - 6” LED dedicated Architectural Retrofit Downlight with integral LED heat management casting and driver. Available in 800 lumens (16W), 1100 lumens
(21W) & 1500 lumens (34W). Lighting is smooth and comfortable while using 25% less energy than the common 26W & 32W CFL downlight. Plus the eco-friendly
Maxilume LED system features 70% lumen maintenance at 50,000 hours life, with California Title-24-2008 compliance and Energy Star Rating (pending). Designed to
install into an existing downlights mounting frame and convert them into energy efficient LED downlights to save anywhere from 35% up to 75% on energy cost. Fits all
downlights with 6-3/4” aperture. Custom size and aperture, LED retrofit and reflectors are available, please consult factory for further details.
FEATURES - Greater light output than a 26W & 32W CFL while consuming less than 16W to 34W of power. Maxilume LED
luminaires are ideally suited for use in hospitality, health care, commercial, institutions, retail and other architectural applications.
PENDING
6 INCH
ARCHITECTUR AL LED RETROFIT DO WNLI GHT
OPTICS - MAXILUME LED Optilux technology combines unmatched performance
with visual comfort. Spun 0.05” thick reflector has been designed to gather the
light scattered by the LED chip and shape it into functional beams that minimize
brightness and glare, while eliminating lamp image. Proprietary dual level upper
and lower reflector design allows for optimum glare control. Elite engineered
superior quality, light engine; producing 800 lumens (16W) , 1100 lumens (21W)
& 1500 lumens (34W).
LED DRIVER/JUNCTION BOX - The LED driver is rated for 50 to 60Hz at 120V
/277V input, produces less than 20%THD, and has a power factor between 90%
and 100% and is thermally protected for additional safety. MAXILUME’s LED driver
is installed on the junction box cover so it may be serviced from below the ceiling.
UL Listed for through-branch circuit wiring, provided with four ½” knockouts, one
¾” knockout and four Romex knockouts with true pryout slots and strain clamps.
Designed for straight through conduit runs.
PERFORMANCE - Operating system delivers 800 lumens (16W), 1100 lumens
(21W) & 1500 lumens (34W) with a 4100K color temperature. All MAXILUME LED
luminaries are rated at 80+ CRI. All LED luminaries are rated and tested to LM-79
and LM-80 standards by an independent laboratory.
MOUNTING - Our retrofit is designed to install into an existing downlights mounting
frame and convert them into energy efficient LED downlights. Flex is designed to
attach into existing junction box.
THERMAL MANAGEMENT SYSTEM - Using a proprietary cooLED Advanced
Thermodynamic Design, Die-cast aluminum housing and heat management system
are engineered for extremely long life and service period. Heat sink is attached to
top of housing. The LED light engine is attached to the die-cast heat sink and is
easily replaceable and upgradable. Life tests have shown the MAXILUME light
engine output will be maintained at 70% of initial at 50,000 hours of operation.
DIMMABLE - The MAXILUME LED system is fully dimmable down to 10% of
initial light output with a 0-10 Volt dimmer when ordered with the following options
(DIM10-120, DIM10-277). Fixtures can be shipped with a Lutron Hi-lume A series
Driver which can be dimmed with Lutron Dimming Systems when ordered with the
following options (LUTH-120, LUTH-277). Triac & Electronic Low Voltage dimming
driver also available when ordered with the following options (DIMTR-120). Consult
Factory for details.
OUR WORD - The MAXILUME LED lighting system is warranted for 3 years. As a
system, we stand behind the entire MAXILUME product.
LISTING
c-UL-us listed for Damp location.
c-UL-us listed for feed Through Wiring.
LM79 / LM80
DIMMING INFORMATION
DIMTR (Triac & Electronic Low Voltage Dimming)
DIM10 (0-10V Dimming)
LUTH (Lutron® Hi-lume® Dimming)
HVJ6-LED
TYPE
800 LUMENS
HVJ6-LED o 16W-DIMTR-120
o 16W-LUTH-120
o 16W-LUTH-277
o 16W-DIM10-120
o 16W-DIM10-277
1100 LUMENS
o 21W-LUTH-120
o 21W-LUTH-277
o 21W-DIM10-120
o 21W-DIM10-277
1500 LUMENS
OPTICS
o 34W-LUTH-120 o FL
o 34W-LUTH-277
o 34W-DIM10-120
o 34W-DIM10-277
COLOR
o 30K
o 35K
o 41K
EMERGENCY TRIM TYPE
o EMG-LED o LED-6101
o LED-6102
o LED-6107
o LED-6109
o LED-6110
o LED-6128
o LED-6123
o
o
o
o
o
o
o
LED-6112
LED-6113
LED-6114
LED-6115
LED-6121
LED-6122
LED-6125
REFLECTOR/ RING FINISH
o CL-WH
o W-WH
o CL-SCH
o MB-WH
o SHZ-SHZ
o WT-WH
o SHZ-WH
DISC
o BLUE
o RED
o GREEN
o FROST
o AL
o BZ
o WH
Example: HVJ6-LED-21W-DIM10-120-FL-30K-LED-6101-CL-WH
84 • TEL: 1-877-375-5555 • FAX: 1-877-375-3333 WWW.MAXILUME.COM & WWW.IUSEELITELED.COM
ALL PRODUCTS ARE U.S. AND FOREIGN PATENT PENDING
6” LED OPTICS
EXAMPLE: LED-6102-CL-WH
EXAMPLE: LED-6101-CL-WH
LED-6101 - REFLECTOR
REFLECTOR/ RING FINISH:
CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH
A= 7-1/8”
B= 7-3/8”
A= 7-1/8”
B= 7-3/8”
EXAMPLE: LED-6114-CL-WH
LED-6114 - REFLECTOR W/ FROSTED GLASS LENS
REFLECTOR/ RING FINISH:
CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH
LED-6112 - BAFFLE W/ FROSTED GLASS LENS
REFLECTOR/ RING FINISH:
CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH
A= 7-1/2”
B= 7-3/8”
C= 1”
EXAMPLE: LED-6113-CL-WH
A= 7-1/2”
B= 7-3/8”
C= 1”
EXAMPLE: LED-6115-CL-WH
LED-6115 - REFLECTOR W/ TEMPERED CLEAR GLASS
REFLECTOR/ RING FINISH:
CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH
A= 7-1/8”
B= 7-3/8”
C= 1”
EXAMPLE: LED-6112-CL-WH
EXAMPLE: LED-6107-CL-WH
LED-6107 - WALL WASH REFLECTOR
REFLECTOR/ RING FINISH:
CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH
LED-6102 - BAFFLE W/ REFLECTOR
REFLECTOR/ RING FINISH:
CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH
LED-6113 - BAFFLE W/ TEMPERED CLEAR GLASS
REFLECTOR/ RING FINISH:
CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH
A= 7-1/2”
B= 7-3/8”
C= 1”
EXAMPLE: LED-6121-CL-WH
A= 7-1/2”
B= 7-3/8”
C= 1”
LED-6121 - STARDUST DECO RING GLASS
REFLECTOR/ RING FINISH:
CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH
A= 7-1/8”
B= 7-3/8”
C= 1-1/4”
6 INCH
EXAMPLE: LED-6122-CL-WH
EXAMPLE: LED-6123-CL-WH
A= 7-1/8”
B= 7-3/8”
C= 1-1/4”
A= 7-1/8”
B= 7-3/8”
C= 1-1/4”
EXAMPLE: LED-6110-CL-WH
EXAMPLE: LED-6109-CL-WH
LED-6109 - DECO GLASS REFLECTOR
REFLECTOR/ RING FINISH:
CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH
GLASS FINISH:
BLUE, RED, GREEN, FROST
LED-6123 - PRISM DECO RING GLASS
REFLECTOR/ RING FINISH:
CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH
A= 7-1/8”
B= 7-3/8”
C= 1-1/4”
LED-6110 - DOUBLE RING GLASS
REFLECTOR/ RING FINISH:
CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH
GLASS FINISH:
BLUE, RED, GREEN, FROST
A= 7-1/8”
B= 7-3/8”
C= 1-1/2”
ALUMINIUM
DISC
EXAMPLE: LED-6125-CL-WH
EXAMPLE: LED-6128-CL-WH-AL
LED-6128 - DECO GLASS REFLECTOR WITH ALUMINIUM DISC
REFLECTOR FINISH:
CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH
DISC FINISH:
AL, WH, BZ
ALL PRODUCTS ARE U.S. AND FOREIGN PATENT PENDING
A= 7-1/8”
B= 7-3/8”
C= 1-1/4”
LED-6125 - CENTRAL ETCHED FLOAT GLASS
REFLECTOR/ RING FINISH:
CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH
A= 7-1/8”
B= 7-3/8”
C= 1-1/4”
• TEL: 1-877-375-5555 • FAX: 1-877-375-3333 WWW.MAXILUME.COM & WWW.IUSEELITELED.COM 85
ARCHITECTUR AL LED DOW NLI GHT OPTI CS
LED-6122 - EURO DECO RING GLASS
REFLECTOR/ RING FINISH:
CL-WH CL-SCH WT-WH SHZ-WH W-WH SHZ-SHZ MB-WH
6” LED PHOTOMETRICS
HV6-LED-21W-MVOLT-DIM-FL-30K-LED-6101-SHZ
/
HVJ(R)6-LED-21W-MVOLT-DIM-FL-30K-LED-6101-SHZ
INPUT WATTS: 21
LUMENS: 974
CRI: 85
EFFICACY: 41 LPW
CCT: 3000K
Candle Power Distribution (Candelas)
90°
80°
424
70°
849
Zonal Lumens Summary
Zone
0-300
0-400
0-600
0-900
Lumens
828
886
952
974
Lumens Per Zone
Luminance Data (cd/sq.m)
%Lamp
85.3
91.3
98.1
100.3
%Fixt
85.03
91
97.8
100
60°
Angle In
Degrees
Average
00
Average
550
Average
900
450
550
650
750
850
3950
2855
1905
1206
314
3950
2855
1905
1206
314
3950
2855
1905
1206
314
50°
1273
40°
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
30°
1697
0°
20°
10°
4’
6’
8’
10’
12’
106.09
47.15
26.52
16.97
11.79
4.7’
7.1’
9.4’
11.8’
14.2’
Distance to
Plane
Initial Nadir
Footcandles
Beam
Spread
ROOM CAVITY RATIO
Beam Angle: 61°
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
TEST NO.: 26606-1
SPACING CRITERIA: 0.8
Lumens
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
150
369.64
308.78
57.85
39.46
26.92
14.64
6.19
.9
RC RW
80% 70% 50% 30%10% 70% 70% 50% 30% 10% 50%
50% 30% 10% 30% 50% 30% 10% 10% 50% 30% 10% 0
1
2
3
4
5
6
7
8
9
10 119119119119 114 111 109 107 109 104 100 97 104 98 93 90 99 92 87 83 95 87 82 78 91 83 77 73 87 79 73 69 84 75 70 66 80 72 66 63 77 68 63 60 117117117 117 112 109 107 105 107 103 99 96 102 97 92 89 98 91 86 83 93 86 81 78 90 82 77 73 86 78 73 69 82 74 69 66 79 71 66 62 76 68 63 60 111111 111 105 104 102 99 96 94 94 90 87 89 85 82 85 80 77 81 76 73 77 72 69 73 69 65 70 66 62 67 63 59 107107107 102 100 99 96 94 92 92 89 86 87 84 81 83 79 76 79 75 72 76 72 68 72 68 65 69 65 62 67 62 59 102102102 98 97 96 94 92 90 89 87 85 85 82 80 81 78 76 78 74 72 75 71 68 71 68 65 69 65 62 66 62 59 RC - Ceiling Cavity Reflectance
90°
80°
424
467
70°
849
934
Zonal Lumens Summary
Zone
0-300
0-400
0-600
0-900
Lumens
911.26
974.89
1047.92
1071.81
%Fixt
85
91
97.8
100
60°
1273
40°
Angle In
Degrees
Average
00
Average
550
Average
900
450
550
650
750
850
4355
3141
2096
1327
346
4355
3141
2096
1327
346
4355
3141
2096
1327
346
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
30°
1697
1867
0°
20°
10°
116.7
51.87
29.17
18.67
12.97
4.7’
7.1’
9.4’
11.8’
14.2’
Distance to
Plane
Initial Nadir
Footcandles
Beam
Spread
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
Lumens
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
165
406
339.66
63.63
43.41
29.62
16.1
6.81
.99
70% 70% 50% 30% 10% 50%
50% 30% 10% 30% 50% 30% 10% 10% 50% 30% 10% 0
1
2
3
4
5
6
7
8
9
10 119
114
109
104
99 95 91 87 83 80 77 116
111
106
102
97 93 89 86 82 79 76 111
105
99 94 89 84 80 77 73 70 67 106
101
96 91 87 83 79 75 72 69 66 102
98 93 89 85 81 78 74 71 68 66 119
109
100
93 87 82 77 73 69 66 63 119
107 97 89 83 78 73 69 66 62 59 116
109
102
96 91 86 82 78 74 71 68 116
107
99 92 86 81 77 73 69 66 63 116 105 96 88 82 77 73 69 65 62 59 111
103
96 90 85 80 76 72 68 65 62 111 102 94 87 81 77 72 69 65 62 59 106
100
94 88 83 79 75 71 68 65 62 106 99 92 86 81 76 72 68 65 62 59 102
97 91 87 82 78 74 71 67 64 62 90°
80°
424
488
70°
849
976
Zonal Lumens Summary
Zone
0-300
0-400
0-600
0-900
Lumens
952.68
1019.54
1095.54
1120.51
%Fixt
85
91
97.8
100
Angle In
Degrees
Average
00
Average
550
Average
900
450
550
650
750
850
5543
3283
2190
1386
358
5543
3283
2190
1386
358
5543
3283
2190
1386
358
50°
1273
40°
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
30°
1697
1952
0°
20°
10°
Beam Angle: 61°
4’
6’
8’
10’
12’
122
54.22
30.5
19.52
13.56
4.7’
7.1’
9.4’
11.8’
14.2’
Distance to
Plane
Initial Nadir
Footcandles
Beam
Spread
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
Zone
Lumens
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
172.5
425.08
355.1
66.52
55.38
30.96
16.83
7.11
1.03
80% 70% 50% 30%10% 70% 70% 50% 30% 10% 50%
50% 30% 10% 30% 50% 30% 10% 10% 50% 30% 10% 0
1
2
3
4
5
6
7
8
9
10 119
114
109
104
99 95 91 87 83 80 77 116
111
106
102
97 93 89 86 82 79 76 111
105
99 94 89 84 80 77 73 70 67 106
101
96 91 87 83 79 75 72 69 66 102
98 93 89 85 81 78 74 71 68 66 119
109
100
93 87 82 77 73 69 66 63 100
94
88
83
78
74
70
67
63
60
58
TEST NO.: 26606-3
SPACING CRITERIA: 0.8
RC RW
119
111
104
98 92 87 82 78 75 71 68 0
1867.14
1764.4
1482.91
820.82
85.58
56.10
32.89
16.17
6.27
.55
0
0%
0%
Lumens Per Zone
Luminance Data (cd/sq.m)
%Lamp
85
91
97.8
100
60°
1464
102 96 90 84 80 75 71 68 65 62 59 0
5
15
25
35
55
55
65
75
85
90
RW - Wall Reflectance
HV6-LED-21W-MVOLT-DIM-FL-41K-LED-6101-SHZ
/
HVJ(R)6-LED-21W-MVOLT-DIM-FL-41K-LED-6101-SHZ
INPUT WATTS: 21
LUMENS: 1121
CRI: 85
EFFICACY: 52 LPW
CCT: 4100K
Candle Power Distribution (Candelas)
Candela Tabulation
Zone
80% 70% 50% 30%10% 119
111
104
98 92 87 82 78 75 71 68 100
94
88
83
78
74
70
67
64
61
58
TEST NO.: 26606-2
SPACING CRITERIA: 0.8
RC RW
RC - Ceiling Cavity Reflectance
ROOM CAVITY RATIO
LED ARCH ITECTURA L DOW NLI GHT
4’
6’
8’
10’
12’
ROOM CAVITY RATIO
6 INCH
Beam Angle: 61°
0
1679
1604
1348
746
78
51
30
15
6
1
0
0%
0%
Lumens Per Zone
Luminance Data (cd/sq.m)
%Lamp
85
91
97.8
100
50°
1400
0
5
15
25
35
55
55
65
75
85
90
RW - Wall Reflectance
HV6-LED-21W-MVOLT-DIM-FL-35K-LED-6101-SHZ
/
HVJ(R)6-LED-21W-MVOLT-DIM-FL-35K-LED-6101-SHZ INPUT WATTS: 21
LUMENS: 1071
CRI: 85
EFFICACY: 50 LPW
CCT: 3500K
Candle Power Distribution (Candelas)
Candela Tabulation
Zone
119
107 97 89 83 78 73 69 66 62 59 RC - Ceiling Cavity Reflectance
116
109
102
96 91 86 82 78 74 71 68 116
107
99 92 86 81 77 73 69 66 63 116 105 96 88 82 77 73 69 65 62 59 111
103
96 90 85 80 76 72 68 65 62 111 102 94 87 81 77 72 69 65 62 59 106
100
94 88 83 79 75 71 68 65 62 106 99 92 86 81 76 72 68 65 62 59 102
97 91 87 82 78 74 71 67 64 62 102 96 90 84 80 75 71 68 65 62 59 Candela Tabulation
0
5
15
25
35
55
55
65
75
85
90
0
1952.01
1844.6
1550.31
858.13
89.47
58.65
34.38
16.9
6.55
.57
0
0%
0%
100
94
88
83
78
74
70
67
63
60
58
RW - Wall Reflectance
88 • TEL: 1-877-375-5555 • FAX: 1-877-375-3333 WWW.MAXILUME.COM & WWW.IUSEELITELED.COM
ALL PRODUCTS ARE U.S. AND FOREIGN PATENT PENDING