MECHANICAL SPECIFICATIONS: HIGH EFFICIENCY WATER COOLED ROTARY SCREW COMPRESSOR 134A CONDENSING UNIT • Single Rotary Screw compressor. • Suction and discharge service valves (not supplied by some of our competitors). • Rubber mounted to the frame. • Compressor internal thermal motor protection and high discharge temperature sensors. • 120 volt fused crankcase heater. • Liquid line sight glass moisture indicator. • Replaceable core filter dryer. • Electronic expansion valve that also acts as a liquid line solenoid (shipped loose for field installation). • Single circuit brazed plate condenser, 316L plates copper brazed. • Condenser certified to UL 207 7th edition and C22.2 no. 140.3-M1987. • Refrigeration pressure relief valve. • Refrigeration rating 450 psi at 383°F. • Water rating 400 psi at 383°F. • 6" or 8" schedule 40 steel pipe main header and branch headers with roll groove ends and couplings two (2) grooved evaporator valves. • NEMA 1 control panel with on-off switch power on light. • Chillers certified to CAN/CSA C22.2 No. 236 / UL 1995 3rd 2005 Heating and Cooling Equipment. • Compressor circuit breaker with through-the-door handle to turn off (disconnects power). • Part Wind Start with two (2) compressor contactors with solid state overloads and time delay relay. • 24 VAC – 250 VA chiller controller transformer with primary and secondary fuses. • 120 VAC – 250 VA control voltage transformer with primary and secondary fuses. • Chiller controller senses and displays all operating and fault conditions with a four (4) line liquid crystal display located in the control panel door. CHILLER CONTROLLER • Four line liquid crystal display located in control panel door. • Displays in English all operating and fault conditions. • Default screen displays entering and leaving chilled water temperature and two (2) icons of a compressor one above the other representing the upper and lower compressors, an outline of the compressor shows it off, a dark icon shows the compressor operating. An exclamation mark inside the outline of the compressor indicates a compressor fault condition. • In a stand-alone • Prevents short cycling of compressors by setting minimum run time and off time. • Sets “stage up time” and “stage down” of compressors and capacity control steps. • Lead – lags compressors on a first in – first out basis to try and equalize run time. • Changes the lead compressor if one has accumulated more run time by 12 hours. • Logs the number of compressors starts and run hours of each compressor. • Senses and displays entering and leaving chilled water temperature. • Senses and displays low leaving chilled water temperature (freezestat). • Senses and displays refrigerant high pressure and low pressure each circuit. • Second mechanical high pressure cut in compressor control circuit, to protect against controller failure. • Displays compressor motor internal protection fault sensing windings and discharge temperatures • Displays water flow switch fault. • In a Group • Protects its compressor from fault conditions. • Reports operating and fault conditions back to System Remote Master. • Compressors are staged by System Remote Master. • Inputs and Outputs • Remote on/off input to start chiller when no communications card is used. • Remote 4 to 20 ma input to change set point when no communications card is used. • Output for alarm fault condition when no communications card is used. • Outputs with 4-20 ma for control of motorized valves. • Outputs to start either a chilled water pump or condenser water pump.