ADS32X Touch Tracker with Video Matrix Switcher Installation

advertisement
ADS32X Touch Tracker
with Video Matrix Switcher
4. Connect the power transformer cable and the
SensorNet data cable, and if required, the data
cable to EIM #2, to the compression connector,
and connect it to J3 on each EIM.
Parts Required
Touch Tracker Installation Kit:
5. Wire the DB9 connector to the data cable. See
the tables in Figure 1. Assemble the hood onto
the DB9 connector.
Part Number 0351-0474-07
INSTL KIT, TOUCH TRKR, W/RJ45
Description
1
Qty
Part No.
CABLE ASSY,MDLR,14FT,8 COND,CROSS-P
1
6003-0047-01
SCR,THD CUT,M2.9X9.5,PHP,ST,Z,T1
1
5899-0004-102
ANCHOR,PLASTIC,W/O SCREW,8-10
2
2880-0083-01
SCR,TYP AB,PHP,CAD,#8X1"
2
2816-7634-44
CONN,PLUG,TUBLR,.200CTR,26-12AWG,1X
1
2109-0254-04
3
2141-0002
LUG,SPADE,CRIMP,INSUL,22-16AWG
CABLE,3COND,18AWG,CM
16.5
6002-0024-01
INTERCONNECT BOX,TOUCHTRACKER
1
0300-1000-01
CABLE ASSY,TOUCH TRACKER,INTFC TO Q
1
0650-0932-01
HOOD,D-SUB,9POS,EMI/RFI,.25 DIA CAB
1
2125-0007-02
CONN,D-SUB,PLUG,HSG,9POS,SSI
1
2130-0021-01
FERRITE CORE
1
2700-0023-01
QUICK REFERENCE GUID
1
8000-1674-01
TOUCH TRACHER STRAIN RELIEF INSTR
1
8000-1370-01
Installation Procedures
WARNING
RISK OF ELECTRIC SHOCK!
Disconnect AC Power.
CAUTION—ELECTROSTATIC
SENSITIVE DEVICES!
Follow proper handling procedures to
prevent component failure.
See Remote Switcher Location for procedures
when the Video Matrix Switcher will be more than 4m
(14 ft) from the EIMs.
1. Attach each EIM to a wall or other surface within
3m (10 ft) of its Touch Tracker controller.
2. Terminate the EIM that is at the end of the
SensorNet network.
See Figure 1 for the wiring diagram for a typical 2controller AD32 system installation. For more
information on the SensorNet network, see the
SensorNet Network Guide (PN 8000-0970-01).
3. Attach the 3 spade lugs to one end of the 3conductor cable, then attach the lugs to the EIM
power transformer.
8000-1691-02. Rev. A (7 pages)
Installation Instructions
6. Install the ferrite core onto the cable assembly,
2.54-3.81cm (1 in.-1.5 in.) from the RJ45
connector (see Figure 2).
7. Connect the data cable to J1 on the EIM to the
RS232 port 1 (primary) or port 2 (secondary) on
the rear panel of the Video Matrix Switcher.
8. Connect a modular cable to J2 on EIM and to the
Touch Tracker controller.
9. Plug each power transformer into a grounded,
3-wire receptacle.
NOTE: If the keypad and backlighting do not
illuminate when power is applied, unplug the
power transformers, check all wiring connections,
and repeat step 9.
10. Press Menu on the Touch Tracker keypad to
calibrate the controller.
11. Using the Tracker Ball, page down the screen to
the Calibration menu option.
12. Press the zoom button to select the Calibrate
menu option if it is displayed on the top line of the
LCD window, or press the focus button if it is
displayed on the second line.
13. Perform the Tracker Ball operations displayed in
the LCD window until Calibration Done
appears in the window.
14. Press Menu to save the configuration and return
to the Camera Control mode.
15. To configure the Touch Tracker controller as a
primary or secondary unit, page down the screen
to the Tog Primary/2nd menu option.
16. To select the Tog Primary/2nd menu option,
press the zoom (top line) or focus (bottom line)
button, as appropriate.
17. Press Next to toggle between using the Touch
Tracker controller as the primary unit or as the
secondary unit.
18. Press Menu to reset the Touch Tracker controller
as a primary or secondary unit. The controller will
reboot to the Camera Control Mode.
AD32 1
Figure 1. AD32 Wiring Diagram
COLOR
Orange
Yellow
Orange
Yellow
J-Box P8
PIN Function
1
Host A
2
Host B
3
Auxiliary A
4
Auxiliary B
COLOR
Orange
White
Red
Black
Yellow
J-Box P1-P6
PIN Function
1 SensorNet A
2 28Vac
3 Ground
4 28Vac
5 SensorNet B
J-Box #2
J-Box #1
EIM Transformers
P4
P1
P4
P1
P5
P2
P5
P2
P6
P3
P6
P8
24 Vac A
Ground
24 Vac B
5 4 3 2 1
5 4 3 2 1
UniCard
P3
24 Vac A
Ground
24 Vac B
5 4 3
2 1
5 4 3
EIM #1
UniCard P3 Wiring
COLOR PIN FUNCTION
Orange
1 SensorNet A
Yellow
2 SensorNet B
Black
3 24Vac A
Red
4 Ground
White
5 24Vac B
2 1
EIM #2
J3
E1
1-2 TERMIN AT ED
2-3 UNT ERMINA TED
32 1
3 2 1
UNTERMINATED
ASSY
0301-0340-01 REV-
ASSY
0301-0340-01 REV-
J2
J1
NOTE:
The system supports up to 2
controllers. Terminate E1 on
the EIM that is on an end point
of the SensorNet network.
3 2 1
TERMINATED
J2
J1
NOTE:
The maximum combined SensorNet
cable length is 1219m (4000').
RJ45
RJ45
DB9 (M)
DB9 (M)
Secondary
TOUCH TRACKER
RJ45
EIM DB9 (M)
COLOR PIN FUNCTION
Green
3 Receive
Red
2 Transmit
Orange
5 Ground
UniCard
P3
J3
E1
1-2 TERMINATED
2-3 UNTERMINATED
3 2 1
P3
P8
5 2 3
5 2 3
Modular
Cable
RJ45
Primary
TOUCH TRACKER
Data Cable
Ferrite Core
Ferrite Core
5 4 2
RJ45 Wiring
COLOR PIN
Green
5
Red
4
Orange
2
5 4 2
RJ45
RJ45
Video Matrix Switcher
RELAY
ALARMS
CAMERAS
1 2 3 4 5 6 7 8
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
2
4
6
8
10
12
14
16
18
20
22
24
26
28
31
32
SI
NO NC C
MONITORS
1
2
3
1
2
4
5
120Vac, 60Hz or
240Vac, 50Hz
120V
60Hz
3
RS232 PORTS
2
INSTALLATION INSTRUCTIONS
ADS32X TOUCH TRACKER with VIDEO MATRIX SWITCHER
8000-1691-02, Rev. A
Calibrating the Tracker Ball
1. Press Menu. The Calibration menu option
will appear on the first line.
Switching Zoom and Focus
Functions between Left and
Right Buttons
2. Press the zoom (line 1) or focus (line 2) button
to select the Calibration menu option.
1. Press Menu.
3. Follow the instructions on the LCD screen.
2. Using the Tracker Ball, scroll down to
Tog Zoom/Focus.
4. Press Menu to exit.
If you do not follow each instruction on the screen, the
dome may not function properly. Re-calibrate the
Tracker Ball if the dome does not pan or tilt properly.
Calibration is only for the Touch Tracker controller.
3. Press the zoom (line 1) or focus (line 2) button
to select the Tog Zoom/Focus menu option.
4. Press Next to switch the Zoom and Focus
functions between the right and left buttons.
5. Press Menu to save the configuration and exit.
Resetting a Dome
1. Use the number buttons to select the dome to
reset, then press Camera.
2. Press Menu.
3. Using the Tracker Ball, scroll down to
Reset Dome.
4. Press the zoom (line 1) or focus (line 2) button
to select the Reset Dome menu option.
The Touch Tracker will send a request to the selected
dome to reboot.
Switching Primary and
Secondary Functions between
Controller Units
Adjusting V-Phase
1. Press Menu.
2. Using the Tracker Ball, scroll down to Adjust VPhase.
3. Press the zoom (line 1) or focus (line 2) button
to select the Adjust V-Phase menu option.
4. Press Next or Prev to observe V-Phase through
the oscilloscope or Fluke scope.
5. Press Menu to exit.
Off-line domes or fixed cameras will generate a warning
beep and disallow use of the V-Phase utility. For
additional information on adjusting V-Phase, see the
Service section of the AD32 Installation and Service
Manual.
1. Press Menu.
2. Using the Tracker Ball, scroll down to
Tog Primary/2nd.
Figure 2. Ferrite Core Attachment
2.54
- 3.81 cm
0 in
(1" - 1.5")
3. Press the zoom (line 1) or focus (line 2) button
to select the Tog Primary/2nd menu option.
4. Press Next to toggle between using the primary
unit for SensorNet polling and alarm monitoring
or as the secondary unit with limited user
functionality.
5. Press Menu to reset the controller as a primary
or secondary unit.
The controller will reboot and return to the Camera
Control Mode.
ADS32X TOUCH TRACKER with VIDEO MATRIX SWITCHER
8000-1691-02, Rev. A
DB9(M)
Ferrite Core
RJ45
Place 1 loop into core
slot; close core halves;
gently pull cable to
tighten loop.
INSTALLATION INSTRUCTIONS
3
Reviewing System Information
1. Press Menu.
2. Using the Tracker Ball, scroll down to
System Info.
3. Press the zoom (line 1) or focus (line 2) button
to select the System Info menu option. The
LCD screen displays the following message:
Primary/Secondary Indicator:
Primary Unit
<NEXT>
<PREV>
4. Press Next to step through the following
messages:
Flash and EEPROM checksum values:
ROM Checksum
E=0A7B
F=9C82
EEPROM
Checksum
Flash
Checksum
Tracker Ball calibration values:
Right
Min
Max
Down
63 60 61 60
D3 C3 C6 DE
Left
Performing SensorNet Ping
Test
1. Use the number buttons to select a dome to
test, then press Camera.
2. Press Menu.
3. Using the Tracker Ball, scroll down to
Ping Dome/TTR.
4. Press the zoom (line 1) or focus (line 2) button
to select the Ping Dome/TTR menu option
and to start the ping test on the selected
dome. The LCD screen displays the following
message:
*=Device being
No. of pings
transmitted
tested
*Dome
TTR
Tx=0006
Bad=0002
No. of failed
responses
5. Press Next to perform the ping test on the
Secondary Touch Tracker controller unit.
6. Press Menu to exit.
Off-line domes or fixed cameras will generate a
warning beep and disallow use of the SensorNet
network test.
Changing the Port Setting
Up
Flash and EEPROM part numbers (including
version):
Product Code
F 0701-0000-0000
Flash Part Number
and Version
Product Code
E 0701-0000-0000
EEPROM Part Number
and Version
1. Press Menu.
2. Using the Tracker Ball, scroll down to
Port Settings.
3. Press the zoom (line 1) or focus (line 2) button
to select the Port Settings menu option. The
LCD screen displays the following message:
*=Selected mode
*Operating Mode
Download Mode
4. Press Next to change the currently selected
mode.
5. Press Menu to save the change and exit.
5. Press Menu to exit.
4
INSTALLATION INSTRUCTIONS
ADS32X TOUCH TRACKER with VIDEO MATRIX SWITCHER
8000-1691-02, Rev. A
Remote Switcher Location
If the EIM and Touch Trackers will be located more
than 4m (14 ft) but less than 15m (50 ft) from the
Video Matrix Switcher, the following additional
equipment will be needed:
Description
Qty
Part No.
CABLE ASSY,MDLR,14FT,8 COND,CROSS-P
1
6003-0047-01
TERMINAL, RJ45
2
2113-0019-01
ANCHOR,PLASTIC,W/O SCREW,8-10
4
2880-0083-01
SCR,TYP AB,PHP,CAD,#8X1"
4
2816-7634-44
CABLE,3COND,18AWG,4M-15M (14’-50’)
1
6002-0024-01
WARNING: Shock Hazard!
Disconnect AC Power.
CAUTION: static sensitive
components!
Follow proper handling procedures to
prevent component failure.
Installation Procedures
1.
Attach each EIM to a wall or other surface within
3m (10 ft) of its Touch Tracker controller.
2.
Terminate the EIM at the end of the SensorNet
network.
8.
Connect the data cable to J1 on the EIM to the
HP0047 terminal box.
9.
Install a ferrite core onto a modular cable
assembly, 2.54-3.81cm (1 in.-1.5 in.) from an
RJ45 connector (see Figure 2).
10. Connect the modular cable to the remote
HP0047 terminal box and to the RS232 port 1
(primary) or port 2 (secondary) on the rear panel
of the Video Matrix Switcher.
11. Connect a modular cable to J2 on EIM and to the
Touch Tracker controller.
12. Plug each power transformer into a grounded,
3-wire receptacle.
NOTE: If the keypad and backlighting do not
illuminate when power is applied, unplug the
power transformers, check all wiring
connections, and repeat step 9.
13. Press Menu on the Touch Tracker keypad to
calibrate the controller.
14. Using the Tracker Ball, page down the screen to
the Calibration menu option.
15. Press the zoom button to select the Calibrate
menu option if it is displayed on the top line of
the LCD window, or press the focus button if it is
displayed on the second line.
16. Perform the Tracker Ball operations displayed in
the LCD window until Calibration Done
appears in the window.
17. Press Menu to save the configuration and return
to the Camera Control mode.
18. To configure the Touch Tracker controller as a
primary or secondary unit, page down the screen
to the Tog Primary/2nd menu option.
See Figure 1 for the wiring diagram for a typical
2-controller AD32 system installation. See Figure
3 for the wiring diagram for remotely located
Video Matrix Switcher. For more information on
the SensorNet network, see the SensorNet
Network Guide (PN 8000-0970-01).
19. To select the Tog Primary/2nd menu option,
press the zoom (top line) or focus (bottom line)
button, as appropriate.
3.
Attach the HP0047 terminal boxes to a wall. The
remote terminal box must be within 15m (50 ft) of
the EIM terminal box.
20. Press Next to toggle between using the Touch
Tracker controller as the primary unit or as the
secondary unit.
4.
Connect the 3-wire, 18AWG shielded cable to
the terminal boxes (see Figure 3).
5.
Attach the 3 spade lugs to one end of the 3conductor cable, then attach the lugs to the EIM
power transformer.
21. Press Menu to reset the Touch Tracker controller
as a primary or secondary unit. The controller
will reboot to the Camera Control Mode.
6.
Connect the power transformer cable and the
SensorNet data cable, and if required, the data
cable to EIM #2, to the compression connector,
and connect it to J3 on each EIM.
7.
Wire the DB9 connector to the data cable. See
the tables on page 2. Assemble the hood onto
the DB9 connector.
ADS32X TOUCH TRACKER with VIDEO MATRIX SWITCHER
8000-1691-02, Rev. A
INSTALLATION INSTRUCTIONS
5
Figure 3. VMS Wiring Diagram—Remote Switcher Location
24 Vac A
Ground
24 Vac B
5
4
3
2
Transformer
1
EIM
J3 Wiring
Pin
1
2
3
4
5
J3
J2
J1
Function
N/A
24Vac A
Ground
24Vac B
N/A
RJ45
DB9 (M)
Modular
Cable
DB9 (M) Wiring
Color
Green
Red
Orange
Pin
3
2
5
RJ45
Function
Receive
Transmit
Ground
Data
Cable
RJ45 Wiring
Color
Green
Red
Orange
Touch Tracker
523
542
Pin
5
4
2
Modular
Cable
RJ45
8
EIM
Terminal
Box
RJ45
1
8
7
2
7
2
6
5 4 3
6
5 4 3
Remote
Terminal
Box
1
Ferrite
Core
3-wire,
18AWG
RJ45
Shield
Video Matrix Switcher
RELAY
ALARMS
CAMERAS
1 2 3 4 5 6 7 8
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
2
4
6
8
10
12
14
16
18
20
22
24
26
28
31
32
SI
NO NC C
MONITORS
1
2
3
1
2
4
5
120Vac, 60Hz or
240Vac, 50Hz
120V
60Hz
3
RS232 PORTS
6
INSTALLATION INSTRUCTIONS
ADS32X TOUCH TRACKER with VIDEO MATRIX SWITCHER
8000-1691-02, Rev. A
Connections
Alarm and Relay
Connections
Alarms
The back panel of the AD32 Video Matrix Switcher
provides eight alarm contact inputs, an external
frequency synchronization input, and contact
terminations for an internal alarm-activated relay.
You can program the Form-C internal relay to
activate during alarms for control of a VCR or other
alarm response device.
Pin 16
RELAY
ALARMS
1 2 3 4 5 6 7 8
SI
Alarm contact closures must have a resistance
of 500 Ohms or less.
•
Connect alarm contacts to inputs 1 through 8
(pins 2 through 9).
•
Connect alarm contact returns to Ground (pin
1 or 10).
External Sync
Figure 4. Alarm/Relay Connections
Pin
•
•
External sync input signal must be 1-5Vrms,
50/60Hz.
•
Connect external sync input to SI (pin 12).
•
Connect external sync ground to Ground (pin
11).
NO NC C
Relay
RELAY
ALARMS
•
Connections for the internal relay are normally
open (NO), normally closed (NC), and
common (C). The relay contact ratings are
0.6A @ 120Vac / 0.3A @ 240Vac or 2.0A @
30Vdc.
•
Connect an alarm-response device requiring a
normally open circuit to NO (pin 14) and C (pin
16).
•
Connect an alarm-response device requiring a
normally closed circuit to NC (pin 15) and C
(pin 16).
CAMERAS
1 2 3 4 5 6 7 8
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
2
4
6
8
10
12
14
16
18
20
22
24
26
28
31
32
SI
NO NC C
MONITORS
1
2
3
1
2
4
120Vac, 60Hz or
240Vac, 50Hz
5
120V
60Hz
3
RS232 PORTS
Video Matrix Switcher—Rear Panel
The following is a description of the alarm and
relay connector pins.
Pin
Description
1
Ground
2
Alarm 1
3
Alarm 2
4
Alarm 3
5
Alarm 4
6
Alarm 5
7
Alarm 6
8
Alarm 7
9
Alarm 8
10
Ground
11
External Sync Ground
12
External Sync Input
13
Ground
14
Relay–Normally Open
15
Relay–Normally Closed
16
Relay–Common
ADS32X TOUCH TRACKER with VIDEO MATRIX SWITCHER
8000-1691-02, Rev. A
INSTALLATION INSTRUCTIONS
7