Fseries Frequency,Tacho,Counting,Batch Meter FH series Inteligent Frequency/Counting/Length/Height/Linespeed Integreted Meter Fseries Frequency,Tacho,Counting,Batch Meter FH series Inteligent Frequency/Counting/Length/Height/Linespeed Integreted Meter MYPIN MYPIN Features Press button setting,can measuring various frequency,tacho,linespeed,with counting,length function at the same time 2 segment optional parament setting,optional frequency dividing,length parameter setting INPUT/OUTPUT opical isolation,high anti-interference 2 road input with ADD/subtract function,can match with various encoder. 4 digit/ 6 digit LED display,sensor power supply 2 Alarm Output,several output mode selectable. one analog current output with various measuring signal selectable(in frequency measuring state) FH8 FH7 RS485 communication interface,MODBOS RTU protocol selectable AC 90-260V NO 12 11 9 10 8 7 6 5 4 2 ← ← 3 1 RST NC OUT1 OUT2 FH8 12V RST GND INB INA Code Illustration MFH□□-□□□□□□ Signal input: Blank:universal 2:others Power supply: A:12V B:24V Communication: Blank:without 2:RS232 4:RS485 OUT2 Dimension Mode 80 Input Mode A,B,C,D Counting N:without R:RELAY Size Installing Dimension S:SSR/LOGIC OUT1 N: without R:RELAY S:SSR/LOGIC T:SCR Input Mode B UP/DOWN(add/subtract) Input Mode A UP(add) Input Counting T:SCR Controllor Terminal Input Counting Controllor Terminal Digits display: : 4:4 digits 6:6 digits Size: 4:48H×48W 7:72H×72W INB at high level,INA inpur not allown; INB at low level,INA at UP counting 8:48H×96W Input Mode C UP/DOWN(add and subtract Input Counting MFH series count/tacho multi-meter Technical Parameter Pulse signal: square wave and 0≤L≤2V up edge active INA for Count,INB for frequency,Please short connect INA and INB if only one output is needed. Insulation resistance ≥20MΩ Consumption:<5W Power supply 90-260V AC/DC or 15-30V AC/DC www.mypinchina.com 3 9 INA 4 10 RST 5 11 +12V AL1 NC NO 6 90-260V AC INB OUT1 90~260V AC 8 12 FH4 1 10 INA 2 11 INB 3 12 RST NO 13 GND 5 14 +12V 6 15 7 16 8 17 9 18 4 NC OUT2 SCR ← SSR Contact relay 250V AC/3A or 30V DC/5A resistance load capacity Operation 0~50℃ 35~85%RH environment ← RELAY 30mA max 2 ← 24V/12VDC ± 10% GND RST (According to the display digit) 0.00001-999999 7 RST Output type (According to the display digit) -199999-999999 1 ← Counting speed 30/5000CPS Auxiliary power Input Mode D UP/DOWN (phase difference input,used as Encoder) Input Counting Input Counting NO NC FH7 Counting Value Counting Value INA:UP countiing terminal INB:DOWN counting terminal Input impedance ≥10KΩ Preset range Input Counting INA at high level,INA at DOWN counting INB at high level.INB at UP counting Connection Input signals sine wave :5≤H≤30V Counting range: Counting Value Counting Value Power: Blank:90-260V AC 50/60HZ E:15-30V AC/DC Input Mode Selection Input Mode Mode Mode Mode Mode INA Signal advance INB Signal,UP counting active; INA Signal lagging dehind INB Signal,DOWN counting active; Function Illustration INA: UPcounting,INB:GATE function,If INB is high level or short connected with +12V,INA Input is not allown INA:UP counting,INB:Countdown control function,If INB is high level,INA changes to DOMN counting INA:UP counting, INB:DOWN counting INA Signal advance INB Signal,UP counting active; INA Signal lagging dehind INB Signal,DOWN counting active; Output Mode Selection Output Mode Mode Mode Mode Mode Mode Mode Function Illustration UP count to setting value HI , display value delay some time ,and reset automatically(we call it Automatic Reset) UP count to setting value HI , display value delays until reset handly or extra connection we call it Manual Reset UP count to setting value HI , display value reset automatically and count again(we call it Automatic Reset) UP count to setting value HI , display value continue to add,untill manual reset or extra connection UP count to setting value HI , HI and LO act as the first and second segment Output Controllor respectively HI and LO act as High limit and Low limit Alarm Output Controllor respectively www.mypinchina.com