MONORAIL KITS INSTALLATION INSTRUCTIONS STARTER JESCO Lighting Group is a UL and ETL listed company Copyright © 2011 JESCO Lighting Group. All rights reserved. IMPORTANT SAFETY INSTRUCTIONS Be sure to read and unsderstand the following instructions completely before installation. 1. All electrical power must be turned off before installation or modification of an exixting system 2. The Monorail system cannot be installed in a damp or wet location 3. Monorail fixtures cannot be installed within 6” of combustible materials 4. Monorail cannot be concealed or extended through a building wall We recommend that the Monorail System be installed by qualified, licensed electrician INSTALLING MONORAIL 1. Start by placing the system on the floor, to roughly indicate the positions of the transformer, connectors, and standoffs. 2. Install Supplied Surface Mounted Transformer: If Surface Mounted Transformer is installed • The standard Surface Mounted Transformer is compatible with 3” standoffs. • For longer drops, install the POWER FEED CABLE EXTENDER now. • Mount transformer to the junction box. If optional Remote Transformer is installed • Determine location of transformer, J-box and canopy. • Pull the appropriate THHN wire from the transformer to the canopy – refer to the Voltage Drop Chart below. If using a SINGLE POWER FEED CANOPY, you will require two leads; if using a DUAL POWER FEED CANOPY, four leads are required. • If using a POWER FEED EXTENSION, install it now. You will need one POWER FEED EXTENSION for a SINGLE POWER FEED CANOPY, or two POWER FEED EXTENSIONS for a DUAL POWER FEED CANOPY. • Install canopy at the junction box. 3. Design bends and assemble rail on the floor. • Bend Rail to desired shape. A BENDING TOOL may be used for more precise bends. • Connect sections of Rail with connectors, ensuring tight connections. • Where power is to be isolated, use non-conductive connectors. • For a finished look, insert end caps over the ends of the Rail. 4. Install Standoff Supports • Mark the ceiling locations where the standoff supports are to be installed. • Standoffs should be placed about three feet apart, with more frequent suspensions on tight curves. The Surface Mounted Transformer itself is a standoff. • Install Standoff supports. 5. Install Rail • Install Rail to the Standoffs and Surface Mounted Transformers. • Ensure that all power connections are tight and secure. • Turn the power on. Using a Voltmeter, be sure that the Rail is supplying the proper voltage. • Turn the power off. 6. Install Quick Adapt Pendants* or Spots* *(not provided with this kit) • Install the MA-FA (FIXTURE ADAPTER) on to the Rail where the Pendants or Spots are to be positioned. You will need one per Pendant or Spot. • Install Pendants or Spots onto the MA-FA (FIXTURE ADAPTER). • Be sure that the power connections are tight and secure. • Note: When using a 24V transformer, 24V lamps are required. 7. Test the Monorail System • Turn the power on for 20 minutes. • Check for any connections that are hot to the touch. (Warm to the touch is not a problem). If any part of the system is hot, the connections must be re-tightened. Note: All halogens lamps generate heat. Do not touch lamps with bare hands. 4. Install Standoff Support 2b. Install Optional Remote Transformer 3. Design Bend & Assemble Rail on the Floor 2a. Install Surface Mounted Transformer 1. Lay system out on floor 5. Install Rail to Power Feed & Standoffs 6. Install Quick Adapt Pendant* or Spot* *(not provided with this kit) 7. Test Monorail System For 20 Minutes MK-150E, MK-300E Type RAIL STARTED KITS Components Project Catalog No. MK-150E & MK-300E The Rails Started Kits are dimmable with electronic low voltage dimmer. The following components are included in each kit: 1 included with MK-150E 1 included with MK-300E 2 included with MK-150E 2 included with MK-300E MST-12012/150E-SN MA-R4-SN ELECTRONIC SURFACE MOUNTED TRANSFORMER Surface Mounted Transformers are installed in a finished ceiling. Transformer housing is a visible part of the system. May be used for dimming, compatible with 3” Standoffs. Can use MA-PFS48/96 (sold separately) for longer drops. MONORAIL Rail with 2 End Caps. Field cuttable. Hand-bendable to a minimum radius of 12”. Rated for 300 watts at 12 Volts; 600 watts at 24 volts. Material: Aluminum Input-Output: Max. Watt: Finish: 3 included with MK-150E 120V-12V AC 150W SN – Satin Nickel CH – Chrome 3 included with MK-300E Description: Finish: 1 included with MK-150E 4’ Rail with 2 End Caps SN – Satin Nickel 1 included with MK-300E MA-FA-SN MA-I-SN FIXTURE ADAPTER Provides connection from Quick Adapt Spots and Pendants to Monorail. One fixture Adapter required per Quick Adapt Spot or Pendant. CONDUCTIVE CONNECTOR I – Conductive Connector joins two sections of Rail to form a straight line configuration allowing power to pass from rail to rail. May be used for longer runs or to create geometric shapes. Description: Finish: 3 included with MK-150E Fixture Adapter SN – Satin Nickel CH – Chrome Description: Finish: Conductive I-Connector SN – Satin Nickel 3 included with MK-300E MA-S03-SN RIGID STANDOFF Unlike standard track systems, Monorail cannot be mounted directly onto the ceiling. It must be suspended from the ceiling. Standoff supports the rail from the ceiling. Start by determining the appropriate type of standoff. Non-Electrical. Description: Finish: 3” Rigid Standoff SN – Satin Nickel CH – Chrome www.jescolighting.com support@jescolighting.com Tech Support: 855.592.0029 6625 Traffic Ave Glendale, NY 11385 Main Line: 800.527.7796 Fax Line: 855.265.5768 Specifications subject to change without notice. 219 South 6th Ave City of Industry, CA 91746 Main Line: 855.654.0110 Fax Line: 626.333.2955 Rev 35 10/23/2013 Page 1 of 1 INSTALLATION INSTRUCTIONS LOW VOLTAGE MONORAIL BASIC COMPONENTS CAUTION Read all instructions before attempting to install this product. Ensure main power is off before attempting to install, modify, or wire this product. Do not install in a wet or damp location. All electrical equipment should be installed by a qualified electrician or technician in accordance with local electrical codes and National Electrical Code. NOTE: Configure design and layout of system on floor before attempting to install any of the following products. MA–FA • Fixture Adapter 1. Unscrew cap from Fixture Adapter. 2. Insert Fixture Adapter onto installed Monorail system. 3. Replace cap onto Fixture Adapter and tighten. MA–I • Conductive Connector & MA-I-NC • Non-Conductive Connector 1. Insert rail into open connector end. 2. Ensure the rail is set completely within the connector. 3. Tighten setscrew with Allen wrench. (Included) Technical Support 855-592-0029 support@jescolighting.com www.jescolighting.com Instruction sheet subject to change without prior notice Rev 79 10/21/2013 Page 1 of 5 INSTALLATION INSTRUCTIONS LOW VOLTAGE MONORAIL BASIC COMPONENTS CAUTION Read all instructions before attempting to install this product. Ensure main power is off before attempting to install, modify, or wire this product. Do not install in a wet or damp location. All electrical equipment should be installed by a qualified electrician or technician in accordance with local electrical codes and National Electrical Code. NOTE: Configure design and layout of system on floor before attempting to install this product. Cap to Power Feed Connection 1. Unscrew the cap from the power feed. 2. Slightly loosen the set screw on the cap, DO NOT REMOVE IT. 3. Place the Monorail into the power feed. 4. Tighten the cap to the power feed. Make sure the cap is not cross threaded. 5. Tighten the set on the cap firmly for proper power connection. Technical Support 855-592-0029 support@jescolighting.com www.jescolighting.com Instruction sheet subject to change without prior notice Rev 79 10/21/2013 Page 4 of 5 TROUBLESHOOTING Is a Quick Adapt Pendant or Quick Adapt Spot not required. When using an optional remote low functioning properly? voltage magnetic transformer, a low voltage • Make sure the lamp is installed properly. magnetic dimmer is required. • Make sure the lamp is not burned out. • Make sure that dimmer’s rated capacity is not • Make sure the MA-FA (Fixture Adapter) is tightly connected. exceeded. • The dimmer is installed to the 120V side, before the transformer. Did the breaker on the main panel trip? • Using an incorrect dimmer will significantly • Verify that the circuit is not overloaded. reduce the life of the transformer. Is the system still not working? Noise Reduction • Make sure the light switch is turned on. Dimming a transformer can sometimes cause • Make sure the transformer has a secure a slight buzzing noise. In some applications, this connection to the power feed and is properly may not be an issue. Following are some and securely connected. recommendations to reduce the buzzing noise: • Make sure all connections do not have any loose wire nuts. • Make sure a compatible dimmer is being used. • Make sure the input wire in the transformer is connected to the 120V. • Install a debuzzing coil. • Power the system up to 80% of capacity, for example, for a 300 watt transformer, do not load Dimming more than 240 watts. • All JESCO Lighting electronic transformers may be dimmed with the appropriate dimmer. • When using a low voltage electronic transformer, a low voltage electronic dimmer is VOLTAGE DROP CHART Using this chart to determine the correct THHN size for an acceptable 3 percent drop in voltage at the specified wattage. The length shown is the length of wire from the remote transformer to the electrical J-box. 5 ft. 6-15 ft. 16-20 ft. 21-40 ft. 41-60 ft. 61-90 ft. 150 watt 300 watt 12 ga. 10 ga. 8 ga. 6 ga. 6 ga. 4 ga. 4 ga. 1 ga. 2 ga. 1/0 ga. 1 ga. 3/0 ga. 300 watt 24 VOLT 600 watt 14 ga. 12 ga. 12 ga. 8 ga. 10 ga. 6 ga. 6 ga. 4 ga. 6 ga. 2 ga. 4 ga. 1 ga. 12 VOLT NEW YORK 66-25 Traffic Avenue Glendale, NY 11385 Tel: 718.366.3211 or 800.527.7796 Fax: 748.366.3646 or 855.265.5768 LOS ANGELES 219 South 6th Avenue City of Industry, CA 91746 Tel: 626.333.3661 or 855.654.0110 Fax: 626.333.2955 Technical Support 855.592.0029 or support@jescolighting.com www.jescolighting.com