Basic Layout of the Wire Chart.
2 2
G P T
Stranding
Insulation
Thickness
Nom.
O.D.
Inches
Pounds
Per 1/M
Feet
Reel
Quantity
Feet
7x30
.023
.074
4
5/m
Breakdown of Each Catagory
2 2
G P T
Most of our wire part numbers are a combination of wire
gauge, type of wire, spool size and then color. Not all numbers
are entered in this way, so to avoid confusion there is an
EXAMPLE (shown to the right) box for every type of wire
s h o w i n g y o u h o w t o e n t e r t h e c o r r e c t p a r t n u m b e r.
7x30
Stranding Specs: This section specifies the number of strands
(metal conductors) that are contained inside the jacket of the
wire. The first number states that the wire you are interested
in has 7 strands. The second number states that each one
of those strands are 30 gauge wire.
Insulation
Thickness
Insulation Thickness: This indicates the thickness of the jacket
material that protects the metal conductor(s). Measurement
is in inches. Example shown on the right.
Stranding
E X AMP LE
18 GPT - 100 - BLU
Wire Gauge
Type of Wire
Spool Size
Color of Wire
.023
Nom.
O.D.
Inches
Nominal Outer Diameter: This gives you the total width of
the wire in inches. Example shown to the right.
.074
Nom.
O.D.
Inches
Nominal Outer Diameter: For bonded and multi-conductor wires, there are two separate numbers. The first one is the
measurement of height of each wire separately. The second is the width of all the wires together. Measurements are in
inches.
Multi-Conductor
Bonded
.091x.195
.091x.195
.091 x .195
Pounds
Per 1/M
Feet
Pounds Per 1/M Feet: This figure determines the amount of
weight of the wire. Each wire is measured in pounds per one
thousand feet.
4
Reel
Quantity
Feet
Bulk Quantity Feet: This category specifies the largest volume
of feet per reel you can purchase when buying in bulk.
5/m
Please keep in mind that some of the charts in the wire section may be different or altered for added
information on special product applications.
61
GPT Primary Wire & GXL Wire
GPT Primary Wire
14 - Stock Colors
White
Black
Red
Blue
Green
Orange
Yellow
Brown
Purple
-
WHT
BLK
RED
BLU
GRN
ORG
YEL
BRN
PUR
Gray
Pink
Lt. Blue
Tan
Lt. Green
- GRY
- PNK
- LBL
- TAN
- LGR
E X AMP LE
18 GPT - 100 - BLU
Type of Wire
Insulation
Thickness
Nom.
O.D.
Inches
7x30
.023
.074
4
22
GPT
20
GPT
7x28
.023
.083
18
GPT
16x30
.023
.092
16
GPT
19x29
.023
14
GPT
19x25
.023
12
GPT
19x25
10
GPT
19x23
8
G P T
6
G P T
4
G P T
Pounds
Bulk
Per 1/M Quantity
Feet
Feet
Drum
Quantity
Feet
5/m
40/m
6
5/m
35/m
9
11 / m
50/m
.104
12
9/m
40/m
. 11 8
17
6/m
30/m
.026
.144
25
4.5/m
20/m
.031
.176
40
3.5/m
12/m
19x21
.037
.216
61
2.5/m
10/m
37x21
.060
.334
120
1/m
--
70x.0233
.057
.375
160
1/m
--
Spool sizes are available in: 100', 500', 1000', bulk reel and drum.
6 ga. and 4ga. available in red and black
only. When ordering Wire use this E X AMP L E
to enter the correct part number
Wire Gauge
Stranding
Spool Size
Color of Wire
Description:
Polyvinyl Chloride (PVC) Insulated
Use: Primarily used in the construction of interior wiring harnesses for passenger cars,
trucks, tractors and off road vehicles.
Conductor: Stranded, bare copper.
Temp. Rating: Recommended temperature range is -40° C to 80° C.
Features: Excellent resistance to abrasion.
S.A.E. J1128, Type GPT • Chrysler Specification MS-3450 • Ford Specification ESF-M1L56A
.
GXL Wire
14 - Stock Colors
White
Black
Red
Blue
Green
Orange
Yellow
Brown
Purple
-
WHT
BLK
RED
BLU
GRN
ORG
YEL
BRN
PUR
Gray
Pink
Lt. Blue
Tan
Lt. Green
- GRY
- PNK
- LBL
- TAN
- LGR
Nom.
O.D.
Inches
Pounds
Per 1/M
Feet
Bulk
Quantity
Feet
7
5/m
20
GXL
7x28
.023
.085
18
GXL
16x30
.023
.094
9
5/m
16
GXL
19x29
.023
.103
12
5/m
14
GXL
19x27
.023
. 11 7
16
5/m
12
GXL
19x25
.026
.142
25
2.5/m
10
GXL
19x23
.026
.176
38
1/m
8
G X L
19x21
.037
.217
60
1/m
6
G X L
37x21
.043
.281
124
1/m
Description:
E X AMP LE
18 GXL - 100 - BLU
Type of Wire
Insulation
Thickness
Spool sizes are available in 100', 500', 1000' and Bulk Reel.
6 ga. available in red and black only. When
ordering Wire use this E X A MP L E to enter
the correct part number
Wire Gauge
Stranding
Spool Size
Color of Wire
Cross Linked Polyethylene S.A.E. Specified
Use: Primarily used in the construction of exterior wiring harnesses for passenger cars,
trucks, tractors and off road vehicles.
Ideal for heat, flame and abrasion resistance if required.
Conductor: Stranded, bare copper.
Temp. Rating: Recommended temperature range is -50° c to 125° c.
Features: Excellent resistance to oil, flame and abrasion. TSC's GXL is labeled every 2 feet:
Temperature, Type, Gauge & SAE.
S.A.E. J1128, Type GXL • Chrysler Specification MS-5919 • Ford Specification ESB-M1L85-B • RVIA
Approved
Note: Keep in mind that BULK quantities of wire may vary from time to time. This is because
vendor may change the amount of footage due to production. If you are interested in bulk it
w i l l b e n e f i t y o u t o a s k o u r Tr o y w a r e h o u s e f o r a n y c h a n g e s i n b u l k q u a n t i t i e s .
62
TXL (Thin Wall) & Bonded Wire
TXL Wire (Thin Wall)
Stranding
Insulation
Thickness
Nom.
O.D.
Inches
Pounds
Per 1/M
Feet
Bulk
Quantity
Feet
22-TXL
7x30
.016
.062
4
5/m
20-TXL
7x28
.016
.070
5
5/m
18-TXL
19x.0092
.016
.078
7
5/m
16-TXL
19x29
.016
.089
9
5/m
14-TXL
19x27
.016
.103
14
5/m
12-TXL
19x25
.018
.124
22
2.5/m
10-TXL
19x23
.020
.155
33
1/m
Spool sizes are available in: 100', 500', 1000' and bulk reels.
Description:
Extra Thin Wall XLP Wire
Use: Can be used in most automotive applications where higher heat resistance, small
diameter and minimal weight is required.
Conductor: Stranded, bare copper.
Temp. Rating: Recommended temperature range is -40° C to 125° C.
Features: Small dia. & high temperature rating is excellent for under hood applications. Conforms
to tight areas
S.A.E. J1128, Type TXL • Chrysler Specification MS-8288 • Ford Specification ESB-M1L123A
14 - Stock Colors
White
Black
Red
Blue
Green
Orange
Yellow
-
WHT
BLK
RED
BLU
GRN
ORG
YEL
Brown
Purple
Gray
Pink
Lt. Blue
Tan
Lt. Green
-
BRN
PUR
GRY
PNK
LBL
TAN
LGR
E X AMP LE
18 TXL - 100 - BLU
Wire Gauge
Type of Wire
Spool Size
Color of Wire
Bonded Wire
# of
Conductors
Stranding
Insulation
Thickness
Nominal
O.D.
Inches
Pounds
Per 1/M
Feet
Bulk
Quantity
Feet
18-2
B
2
16 x 30
.023
.094 x .188
16
14/m
16-2
B
2
19 x 29
.023
.105 x .210
22
12.5/m
14-2
B
2
19 x 27
.023
.122 x .244
32
10.5/m
12-2
B
2
19 x 25
.026
.138 x .280
48
6/m
18-3
B
3
16 x 30
.023
.094 x .282
26
12.5/m
16-3
B
3
19 x 29
.023
.105 x .315
33
10/m
14-3
B
3
19 x 27
.023
.122 x .366
47
8.5/m
12-3
B
3
19 x 25
.026
.147 x .421
74
4.5/m
18-4
B
4
16 x 30
.023
.094 x .376
32
10/m
16-4
B
4
19 x 29
.023
.105 x .420
44
8/m
14-4
B
4
19 x 27
.023
.122 x .488
64
6.5/m
12-4
B
4
19 x 25
.026
.143 x .361
105
2.5/m
16-5
B
5
19 x 29
.023
.105 x .420
55
5/m
Spool sizes are available in: 100', 250', 500', 1000' & bulk reels.
Description:
Flat Multi-Conductor Bonded Wire
Use: Primarily used in the construction of wiring harnesses for passenger cars, trucks,
tractors and off the road vehicles. Use at 50 volts or less.
Conductor: Stranded, bare copper.
Insulation: Polyvinyl Chloride (P.V.C.)
Temp. Rating: Recommended temperature range is -40° C to 80° C.
Features: Excellent resistance to abrasion.
S.A.E. J1128, Type GPT • Chrysler Specification MS-3450 • Ford Specification ESB-M1L56A
Stock Colors
2 Conductor: Red & Black
3 Conductor: Green, Yellow & Brown
4 Conductor: Green, Yellow, Brown & White
5 Conductor: Green, Brown, Yellow, Brown
& White
E X AMP LE
18 - 2 B - 250
Wire Gauge
# of Conductors
Type of Wire
Spool Size
Only 16-2B and 16-4B available in tin plated
marine grade. Call for more information.
W hy us e 16-5 B onded W ire? W ith the a dditiona l brown
(T ail L ight) wire, a cros s over wire on the back of a trailer
is not neces s a ry.
63
Duplex Primary Wire & Speaker Wire
Duplex Primary Wire
Stock Colors
2 Conductor: White & Black
# of
Conductors
Stranding
Insulation
Thickness
Nominal
O.D.
Inches
Pounds
Per 1/M
Feet
Bulk
Quantity
Feet
18-2D
2
16 x 30
.023
.150 x .240
26
9/m
16-2D
2
19 x 29
.023
.162 x .265
36
8/m
14-2D
2
19 x 27
.023
.180 x .300
40
7/m
12-2D
2
19 x 25
.026
.210 x .360
70
5/m
10-2D
2
19 x 23
.031
.235 x .420
105
3.5/m
8-2D
2
19 x 21
.037
.290 x .520
150
2/m
16-3D
3
19 x 29
.023
.162 x .365
50
5/m
14-3D
3
19 x 27
.023
.180 x .420
70
4/m
12-3D
3
19 x 25
.026
.210 x .500
100
3/m
10-3D
3
19 x 23
.031
.235 x .595
145
2.5/m
16-4D
4
19 x 30
.023
.195 x .510
60
3.5/m
14-4D
4
19 x 27
.023
.210 x .560
84
3/m
3 Conductor: Green, White & Black
Spool sizes are available in 100', 500', 1000' and Bulk Reels.
4 Conductor: Green, Red, White & Black
Description:
E X AMP LE
18 - 2 D - 100
Wire Gauge
# of Conductors Type of Wire
Spool Size
For 12-2D with a red jacket and black and
blue inner conductors use
Part #12-2 DR-(spool size)
Duplex Primary Wire
Use: General purpose wiring of automobiles, boats, trucks, buses, tractors, trailers and
other motor driven equipment.
Conductor: Stranded bare copper.
Temp. Rating: Temperature rating 105° C. 50 Volts or less.
Features: Duplex wire is a cable composed of two or more insulated single conductor cables
held together with an outer gray PVC jacket to protect against abrasion and weather.
S.A.E. J1128, Type GPT
Speaker Wire
Standard Colors
E X AMP LE
22 - 2 SW - 100
64
# of Conductors
Type of Wire
Insulation
Thickness
Nom.
O.D.
Inches
Pounds
Per 1/M
Feet
Bulk
Quantity
Feet
22-2
SW
7 x 30
.020
.070 x .145
6
5/m
20-2
SW
10 x 30
.025
.090 x .182
10
5/m
18-2
SW
16 x 30
.025
.095 x .192
11
5/m
16-2
SW
26 x 30
.025
.120 x .210
15
4/m
14-2
SW
41 x 30
.025
.140 x .285
26
3/m
12-2
SW
65 x 30
.030
.150 x .300
50
2.5/m
Spool sizes are available in 100', 250', 500', 1000' and Bulk Reels.
Clear P.V.C. One conductor has tinned
stranding for polarity
Wire Gauge
Stranding
Spool Size
Description:
Speaker Wire - Type PLT-1
Use: Primarily used for HI-FI and stereo speaker wire, lamps, radios and Jukeboxes.
Conductor: Fully annealed 1 bare, 1 tin stranded copper.
Features: Insulated with extra flexible clear P.V.C. for easy handling and installation.
Welding - Battery Cable & Bonded Booster Cable
Combination Welding & Battery Cable
Stranding
Insulation
Thickness
Nom.
O.D.
Inches
Pounds
Per 1/C
Feet
Bulk
Quantity
Feet
SF
6
266
x
30
.075
.375
13
500
SF
4
420
x
30
.075
.430
18
500
SF
2
665
x
30
.076
.510
26
500
SF
1
836
x
30
.072
.540
32
500
SF
1/0
1064
x
30
.080
.610
41
500
SF
2/0
1330
x
30
.084
.670
51
500
SF
3/0
1665
x
30
.089
.740
63
500
SF
4/0
2109
x
30
. 11 0
.830
82
500
Stock Colors
Red - RED
Also available in Tinned Marine Grade
When ordering wire please use the EXAMPLE
below to determine the correct part
.
number
Spool sizes are available in: 25', 50', 100' and 500'
SF
Description:
Use:
Conductor:
Temp. Rating:
Features:
Black - BLK
E X AMP LE
6 - 50 - RED
Combination Welding & Battery Cable
Primarily used for battery cable connections.
Fully annealed stranded copper.
Recommended Temperature Range is -70° F to 221° F.
Super Flex cable is designed for low temperature conditions with an operating flexibility
at minus 70° F. Suitable for all weather. 600 Volt Neoprene Super Flex
Type of Wire
Wire Gauge
Spool Size
Color of Wire
Bonded Booster Cable
Wire Gauge
Stranding
Insulation
Thickness
Nom.
O.D.
Inches
.
Pounds
Bulk
Per 1/C Quantity
Feet
Feet
SF
44
two 4 AWG
420 x 30
.075
.425 x .975
35
500
SF
22
two 2 AWG
665 x 30
.076
.425 x 1.075
52
500
SF
11
two 1 AWG
836 x 30
.072
.530 x 1.025
65
500
Spool sizes are available in: 12', 25', 50', 100' and 500'
Description: Bonded Booster Cable
Use:
Conductor:
Temp. Rating:
Features:
Primarily used for jumper cables.
Fully annealed stranded copper.
Recommended Temperature Range is -70° F to 221° F.
Super Flex cable is designed for low temperature conditions with an operating flexibility
at minus 70° F. Suitable for all weather. 600 Volt TPR Super Flex
TSC supplies booster cable ends (shown below) turn to page 138 for
specifications and which style is best for your requirements.
Stock Colors
Blue Jacket with one red stripe on one
conductor
When ordering wire please use the EXAMPLE
to enter the correct part number.
E X AMP LE
SF 44 - 50
Type of Wire
Wire Gauge
Spool Size
Note: Keep in mind that BULK quantities of wire may vary from time to time. This is because
vendor may change the amount of footage due to production. If you are interested in bulk it
w i l l b e n e f i t y o u t o a s k o u r Tr o y w a r e h o u s e f o r a n y c h a n g e s i n b u l k q u a n t i t i e s .
B attery Terminals continued on following page.
65
Starter / Ground Battery Cable & Trailer Cable
Starter or Ground Battery Cable
Stranding
Insulation
Thickness
Nom.
O.D.
Inches
Pounds
Per 1/M
Feet
Bulk
Quantity
Feet
49 x .0231
.060
.334
12
1000
4 PVC
70 x .0233
.057
.375
16
1000
2 PVC
133 x .0226
.052
.450
25
1000
1 PVC
133 x .0254
.050
.490
31
500
1/0
PVC
133 x .0285
.047
.530
39
500
2/0
PVC
133 x .0315
.058
.595
48
500
6 PVC
Stock Colors
Red - RED
Black - BLK
When ordering wire please use the EXAMPLE
to enter the correct part number.
E X AMP LE
6 PVC - 100 - RED
Wire Gauge
Type of Wire
Spool Size
Spool sizes are available in: 100 and 500
Description:
Color of Wire
Use:
Conductor:
Temp. Rating:
Features:
PVC Insulated Starter or Ground Battery Cable
Primarily used for battery cable connections.
Stranded, bare copper.
Temperature rating at 80° C, 50 Volts or less.
Made of rope stranded copper, paper separated with a PVC jacket.
Trailer Cable
Bulk
Outer Jacket
# of Wires &
Insulation N o m . Pounds
Stranding
Material
Wire Gauge
Thickness O . D . Per 1/M Quantity
Inches
Feet
Feet
& Color
1 4 - 7 N
6 / 12ga.
1 / 10ga.
Internal Colors
1 4 - 7 T
7 / 14ga.
14-4N: 14ga. White, Black, Red & Brown.
14-6N: 14ga. White, Black, Yellow, Red,
Green & Brown.
14-6P: 14ga. Black, Yellow, Red, Green,
Brown & Blue.
14-6T: 14ga. White, Black, Red, Green,
Brown & Blue.
14-7N: 6-12ga. Black, Yellow, Red, Green,
Brown & Blue. 1-10ga. GPT: White.
14-7P: 14ga. White, Black, Yellow, Red,
Green, Brown & Blue.
14-7T: 14ga. White, Black, Yellow, Red,
Green, Brown & Blue.
14-7ABS: 4-12ga. Black, Brown, Green &
Yellow. 2-10ga. Red & Blue. 1-8ga. White.
1 4 - 7 P
1 4 - 7 ABS
E X AMP LE
14 - 7 N - 100
Wire Gauge
# of Conductors
Type of Jacket
Spool Size
65 x 30
.
.038
19 x 23
.690
29
500
Neoprene / Blue
PVC Thin Wall / Black
.560
19 x 27
.023
.375
16
500
7 / 14ga.
19 x 27
.038
.560
22
500
PVC / Black
4 / 12ga.
65 x 30
.138
.690
44
500
PVC / Green
2 / 10ga.
105 x 30
1 / 8ga.
168 x 30
1 4 - 6 T
6 / 14ga.
19 x 27
.023
.375
14
500
PVC Thin Wall / Black
1 4 - 6 P
6 / 14ga.
19 x 27
.035
.490
20
500
PVC / Black
1 4 - 6 N
6 / 14ga.
19 x 27
.035
.580
18
500
Neoprene / Blue
1 4 - 4 N
4 / 14ga.
19 x 27
.030
.460
11
500
Neoprene / Blue
Spool sizes available in 50, 100 & 500. When ordering wire please use the
EXAMPLE to enter the correct part number.
Description:
Multi-Conductor PVC & Neoprene Trailer Cable - S.A.E. J1128
Use: Primarily used for electrical trailer hookup.
Conductor: Stranded, bare copper.
Temp. Rating: Recommended temperature range is -20° F to 80° F. For PVC, -60° C to 105° F for
neoprene.
Features: Trailer cable single conductors are color coded for easy identification. This cable has
excellent resistance to abrasion, oil, grease, acid and weather.
Looking for specialty cable? Terminal Supply Co. has access to quality cable manufacturers which
include: General Cable, Dearborn and Coleman Cable. From Vutron, Diesel Locomotive Cable to
Stagelight Cable call us for a competitive quote.
66
Boat Cable, Test Lead & Lamp Cord
Boat Cable
Stranding
Insulation
Thickness
Nom.
O.D.
Inches
Pounds
Per 1/M
Feet
Bulk
Quantity
Feet
16-2BC
26
x
30
.100
.190 x .310
43
6/m
14-2BC
41
x
30
.100
.200 x .340
61
5/m
12-2BC
65
x
30
.100
.220 x .380
82
4/m
10-2BC
105 x 30
.100
.240 x .420
11 2
2.5/m
16-3BC
26
x
30
.100
.190 x .430
72
4.5/m
14-3BC
41
x
30
.100
.200 x .470
92
3.5/m
12-3BC
65
x
30
.100
.220 x .530
122
3/m
10-3BC
105 x 30
.100
.240 x .600
192
1.5/m
Stock Colors
Outer Jacket: White
2 Conductors: Black & White
3 Conductors: Green, Black & White
When ordering wire please use the EXAMPLE
to determine the correct part number
.
E X AMP LE
14 - 3 BC - 100
Spool sizes are available in 100' & 500' and Bulk Reels.
Description:
Wire Gauge
Tinned Multi-Conductor Boat Cable
Use:
Conductor:
Temp. Rating:
Features:
Primarily used on boats for inverters, power generators and shore power connectors.
Stranded, tinned copper.
105° C Dry - 75° C Wet.
Flat multiple conductor insulated with a tough PVC jacket to meet SAE, UL, ABYC and
coast guard requirements. UL File Number - E67078, 600 Volts.
# of Conductors
Type of Wire
Spool Size
F or wire s trippers , cutters
a nd other va rious wire tools
turn to our M a inte na nc e s e c tion.
Test Lead Wire
T LW - 5 0
Stranding
Insulation
Thickness
Nom.
O.D.
Inches
Pounds
Per 1/C
Feet
Bulk
Quantity
Feet
65 x 36
.045
.140
1.0
50
Red and Black are supplied in 1 bag. Each color is 25 feet in length per bag
for a total of 50 feet.
Description: 18ga. Test Lead Wire
Use: Primarily used for multimeters, analyzers, oscillators and other applications requiring
extra flexible insulated wire.
Conductor: Stranded tinned soft copper.
Temp. Rating: -20° C to +60° C, 5000 volts.
Features: Flexible plastic insulation is durable and has a high-gloss finish. Breakdown voltage
is 20,000V - Suggested working voltage is 5,000V.
Stock Colors
Red
Black
Lamp Cord
18-2
LC
Stranding
Insulation
Thickness
Nom.
O.D.
Inches
Pounds
Per 1/M
Feet
Bulk
Quantity
Feet
41 x 34
.019
. 11 0 x . 2 1 0
6
250'
Stock Colors
Stocked on 250' Spools
Description:
Use:
Conductor:
Temp. Rating:
Features:
SP-1 (2 Conductor Appliance Cord)
Primarily used for lamps, stereos, and jukeboxes.
Fully annealed stranded, bare copper.
Recommended temperature range is -20° C - +60° C.
Jacket insulation is premium grade P.V.C. with polarity ridge for easy identification.
Type SPT-1 300 Volts - 10 Amp capacity UL / CSA Listed.
(Other sizes and colors available upon request.)
White - WHT
Black - BLK
Brown - BRN
When ordering wire please use the EXAMPLE
to determine the correct part number
.
E X AMP LE
18 - 2 LC - 250 - BLK
Wire Gauge
Type of Wire Spool Size Color of Wire
# of Conductors
67
Service Cords Type SOOW, SJ, SJOOW & SOOW Vutron
Service Cord Type SOOW, SJ & SJOOW
Service Cord Type
Type - SOOW
Type - SJ
Type - SJOOW
# of Wires &
Wire Gauge
Stranding
Current
Amps
Nom.
O.D.
Inches
Pounds
Per 1/M
Feet
Nom.
O.D.
Inches
Pounds
Per 1/M
Feet
Nom.
O.D.
Inches
Pounds
Per 1/M
Feet
1 8 - 2
2 / 18ga.
16 x 30
10
.345
75
.295
54
.295
56
1 8 - 3
3 / 18ga.
16 x 30
10
.365
87
.320
70
.320
72
1 8 - 4
4 / 18ga.
16 x 30
7
.390
102
.355
92
.355
96
1 6 - 2
2 / 16ga.
26 x 30
13
.370
78
.320
66
.320
69
1 6 - 3
3 / 16ga.
26 x 30
13
.390
105
.345
89
.345
92
1 6 - 4
4 / 16ga.
26 x 30
10
.415
120
.385
11 2
.385
11 6
1 4 - 2
2 / 14ga.
41 x 30
18
.500
151
.350
87
.350
92
1 4 - 3
3 / 14ga.
41 x 30
18
.530
176
.380
106
.380
11 2
1 4 - 4
4 / 14ga.
41 x 30
15
.570
210
.415
144
.415
136
1 2 - 2
2 / 12ga.
65 x 30
25
.575
201
.425
138
N/A
N/A
1 2 - 3
3 / 12ga.
65 x 30
25
.600
235
.450
173
.450
189
1 2 - 4
4 / 12ga.
65 x 30
20
.650
291
.500
214
.500
225
1 0 - 2
2 / 10ga.
105 x 30
30
.625
245
N/A
N/A
N/A
N/A
1 0 - 3
3 / 10ga.
105 x 30
30
.600
307
.660
250
.660
275
1 0 - 4
4 / 10ga.
105 x 30
25
.710
360
.680
320
.680
344
All service cords are available in 50' 100' and 250' ft. Spools.
Description:
Stock Colors
2 Conductors: Black & White.
3 Conductors: Black,White & Green.
4 Conductors: Black,White, Green & Red.
E X A MP L E
18 - 2 SJ - 250
Wire Gauge
# of Conductors
Type of Wire
Spool Size
Multi-Conductor Type SOOW, SJ & SJOOW Service Cords
Use: Primarily used for portable appliances, tools, small motors, lighting, battery chargers,
. openers, washing machines, refrigerators and sound equipment.
garage door
Type - SOOW: 600 Volt -40° C to +90° C. Oil resistant neoprene jacket, Also available in 8ga.
through 4ga. - 2 to 4 conductors.
Type - SJ: 300 Volt -40° C to +60° C. Junior hard service rubber insulated portable cord.
Type - SJOOW: 300 Volt -40° C to +90° C. Same as Type-SJ, but neoprene oil resistant compound
outer jacket.
To order the correct part# for all service cords; please use the
EXAMPLE chart.
Service Cord Type - SOOW Vutron
# of Wires &
Wire Gauge
Stranding
Current
Amps
Nom.
O.D.
Inches
Pounds
Per 1/M
Feet
1 8 - 3
3 / 18ga.
16 x 30
10
0.380
82
Stock Colors
1 6 - 2
2 / 16ga.
26 x 30
13
0.390
82
2 Conductors: Black & White.
3 Conductors: Black,White & Green.
4 Conductors: Black,White, Green & Red.
1 6 - 3
3 / 16ga.
26 x 30
13
0.400
97
1 6 - 4
4 / 16ga.
26 x 30
10
0.425
111
1 4 - 3
3 / 14ga.
41 x 30
18
0.550
165
To order the correct part# for all service
cords; please use the EXAMPLE chart.
1 4 - 4
4 / 14ga.
41 x 30
15
0.590
186
1 2 - 3
3 / 12ga.
65 x 30
25
0.615
222
1 2 - 4
4 / 12ga.
65 x 30
20
0.670
275
1 0 - 4
4 / 10ga.
104 x 30
25
0.740
339
E X AMP LE
18 - 2 SOOW - V - 250
Wire Gauge
# of Conductors
Type of Wire
Spool Size
All service cords are available in 50' 100' and 250' ft. Spools.
Looking for more conductors or
larger s izes ? C all our toll free
numbe r for produc t a v a ila bility
1 800 989 9632.
68
Description:
Multi-Conductor Type SOOW Vutron Service Cord
Use: Primarily used for portable appliances, tools, small motors, lighting, battery chargers,
garage door openers, washing machines, refrigerators and sound equipment.
Features: 600 Volt -50*C +105*C. Excellent flexibility even in cold temperatrues and resistant to
weather, flame and ozone.
Multi-Conductor Communication Cables
Unshielded Communication Cable
# of Wires
& Gauge
Stranding
Insulation
Thickness
Nom.
O.D.
Inches
Pounds
Per 1/M
Feet
CC-202
2 / 20ga.
7
x
28
.030
.192
21
CC-203
3 / 20ga.
7
x
28
.030
.216
27
CC-204
4 / 20ga.
7
x
28
.030
.235
36
CC-205
5 / 20ga.
7
x
28
.030
.254
46
CC-207
7 / 20ga.
7
x
28
.030
.275
56
CC-182
2 / 18ga.
16
x
30
.030
.222
29
CC-183
3 / 18ga.
16
x
30
.030
.232
40
CC-184
4 / 18ga.
16
x
30
.030
.253
49
CC-185
5 / 18ga.
16
x
30
.037
.275
58
CC-187
7 / 18ga.
16
x
30
.037
.298
77
CC-162
2 / 16ga.
1 9 x . 0 11 7
.030
.268
40
CC-163
3 / 16ga.
1 9 x . 0 11 7
.030
.283
51
CC-164
4 / 16ga.
1 9 x . 0 11 7
.045
.306
95
CC-165
5 / 16ga.
1 9 x . 0 11 7
.045
.334
11 4
CC-167
7 / 16ga.
1 9 x . 0 11 7
.045
.364
130
Standard Colors for
Conductors
2 Conductor: Black & Clear
3 Conductor: Black, Clear & Red
4 Conductor: Black, Clear, Red &
Green
5 Conductor: Black, Clear, Red, Green
& Brown
7 Conductor: Black, Clear, Red, Green,
Brown, Blue & Orange
When ordering wire please use the EXAMPLE
to enter the correct part number.
CC
Type of Wire
E X AMP LE
- 20 2 - 100
Wire Gauge
# of Conductors
Spool Size
Spool sizes are available in 100', 500' & 1000'
Description:
Multi-Conductor Communication Cable - Unshielded
Use: Primarily used for public address systems, intercoms, internal telephones and remote
control circuits.
Conductor: Fully annealed stranded tinned copper.
Temp. Rating: Recommended temperature range is -20° C to +80° C - 300V.
Features: Jacket is made of PVC gray, to protect conductors from normal wear. UL style 2464 •
NEC article 800 type CM • OSHA acceptalbe • Passes CSA FTY & UL's - • 70,000 BTU
Vertical flame test • CSAPCC (CSA 60*C)
Shielded Communication Cable
Insulation
Thickness
Nom.
O.D.
Inches
Pounds
Per 1/M
Feet
28
.030
.203
23
x
28
.030
.213
30
x
28
.030
.234
36
30
.030
.229
30
30
.030
.247
40
30
.030
.238
50
.030
.314
55
.030
.332
60
# of Wires /
Gauge - Ground
Stranding
CCS-202
2 / 20ga.- 20
7
x
CCS-203
3 / 20ga.- 20
7
CCS-204
4 / 20ga.- 22
7
CCS-182
2 / 18ga.- 20
16
x
CCS-183
3 / 18ga.- 20
16
x
CCS-184
4 / 18ga.- 20
18
x
CCS-162
2 / 16ga.- 18 1 9 x . 0 11 7
CCS-163
3 / 16ga.- 18 1 9 x . 0 11 7
Spool sizes are available in 100', 500' & 1000'
Description:
Multi-Conductor Communication Cable - Shielded
Use: Primarily used for Industrial equipment controls, computers, broadcast and sound
systems.
Conductor: Fully annealed stranded tinned copper.
Temp. Rating: Recommended temperature range is -20° C to +80° C - 300V.
Features: Jacket is made of PVC gray, to protect conductors from normal wear.
Shield is 100% Flexfoil Aluminum / Polyester 25% overlap, foil facing out. UL style
2464 •NEC article 800 type CM •OSHA acceptalbe •Passes CSA FTY & UL's 70,000 BTU
Vertical flame test • CSAPCC (CSA 60*C)
Standard Colors for
Conductors
2 Conductor: Black & Clear
3 Conductor: Black, Clear & Red
4 Conductor: Black, Clear, Red &
Green
5 Conductor: Black, Clear, Red, Green
& Brown
7 Conductor: Black, Clear, Red, Green,
Brown, Blue & Orange
When ordering wire please use the EXAMPLE
to enter the correct part number.
CCS
Type of Wire
E X AMP LE
- 20 2 - 100
Wire Gauge
# of Conductors
Can't find the cable for your application? As an authorized distributor for General Cable and
Alpha Wire, we have quick and competitive access to a broad range of communication, control
and coaxial cable. Call our troy office for a quick response of specialty wire and cable products.
Spool Size
69
Coaxial Cable, Coaxial Cable Connectors & Mechanics Wire
Coaxial Cable
Inner Conductor
Dielectric Insulation
Shield & Type
Nominal %
Coverage
Impedance
ohms
AWG
Strand
Material
Material
Nom.
O.D.
Inches
Material
Nominal %
Coverage
RG-58U
PVC / BLK
.195
53
20
Solid
Bare
Copper
Solid
Polyethylene
. 11 6
Tinned
Copper Braid
81
RG-58AU
PVC / BLK
.195
50
20
19 x .0071
Tinned
Copper
Solid
Polyethylene
. 11 6
Tinned
Copper Braid
95
RG-59U
PVC / BLK
.242
75
22
Solid
Copper
Coated Steel
Solid
Polyethylene
.146
Bare
Copper Braid
95
RG-6U
PVC / BLK
.240
75
18
Solid
Copper
Coated Steel
Cellular
Polyethylene
.180
Flexfoil
Shield
100
RG-58U
RG-58AU
RG-6U
Description:
When ordering wire please use the EXAMPLE
to enter the correct part number.
E X AMP LE
RG - 58U - 100
Type of Wire
RG-59U
Single Conductor - Coaxial Cable
RG-58U
Primarily used for radio frequency and broadcast.
RG-58AU
Primarily used for radio frequency and broadcast.
RG-59U
Primarily used for radio frequency, signal transmission, MATV, CATV, local area network,
citizen band radio, computer applications and cathode ray tube (CRT).
RG-6U
Primarily used for RF signal transmission, digital video, CATV, MATV, local area network
and FM Broadcast.
Spool Size
Spool sizes are available in: 100 and 1,000 feet.
Coaxial Cable Connectors
Fig.
Cable
Type
Description
A
58
BNC - Plug - Crimp type
CMC-3002
B
59
BNC - Plug - Crimp type
CMC-4001
C
58
TNC - Plug - Crimp type
CMC-4002
D
59
TNC - Plug - Crimp type
CMC-7002
E
59
F - Series - Crimp type
CMC-7001
F
6
F - Series - Crimp type
CMC-3001
Mechanics Wire
Stranding
AWG
Nom.
O.D.
Inches
Pounds
Per
Spool
Reel
Quantity
Feet
MW-18
Solid
18
.048
5
830
MW-16
Solid
16
.060
5
480
MW-14
Solid
14
.073
5
295
Description:
Mechanics Wire
Use: Mechanics wire has over 1000 uses to secure just about anything.
Standard color Black
Conductor: Single conductor black finish
70
Machine Tool Wire (MTW), TFFN, THHN, & Spark Plug Cable
Machine Tool Wire
Stranding
Insulation
Thickness
Nom.
O.D.
Inches
Pounds
Per 1/M
Feet
Bulk
Quantity
Feet
18
MTW
16 x 30
.031
. 11 0
10
5/m
16
MTW
1 9 x . 0 11 7
.031
.122
14
5/m
14
MTW
19 x .0147
.031
.136
20
5/m
12
MTW
19 x .0185
.031
.155
27
3/m
10
MTW
19 x .0234
.031
.180
43
2/m
8
M T W
19 x .0295
.031
.246
72
500
6
M T W
19 x .0372
.030
.260
120
500
4
M T W
19 x .0469
.040
.331
150
500
Color Code Chart
Black
White
Red
Blue
Brown
Green
Ye l l o w
Orange
Gray
Pink
Purple
Light Blue
Spool sizes are available in 500 and bulk.
Description:
Single Conductor - Machine Tool Wire (MTW)
Use: Primarily used for motor & transformer lead, external wiring of machinery and building
wire.
Conductor: Fully annealed stranded bare copper.
Temp. Rating: Recommended temperature range is -40° C to +90° C, 600V.
Features: Outstanding resistance to oil, flame, abrasion, moisture, corrosion and heat. UL and
NMTBA type MTW/AWM •CSA AWM •Passes VW-1 vertical flame test •OSHA acceptable.
-
BLK
WHT
RED
BLU
BRN
GRN
YEL
ORG
GRY
PNK
PUR
LBL
When ordering wire please use the EXAMPLE
to enter the correct part number.
E X AMP LE
18 MTW - 500 - BLU
Wire Gauge
Type of Wire
Spool Size
Color of Wire
TFFN & THHN Wire
Insulation
Thickness
P.V.C.
Nylon
Stranding
18
TFFN
16
N o m . Pounds
O . D . Per 1/M
Inches
Feet
Bulk
Quantity
Feet
16 x 30
.015
.004
.090
8
2.5/m
TFFN
1 9 x . 0 11 7
.015
.004
.104
12
2.5/m
14 THHN
19 x .0147
.015
.004
. 11 6
17
2.5/m
12 THHN
19 x .0185
.015
.004
.135
25
2.5/m
10 THHN
19 x .0234
.020
.004
.169
40
2.5/m
8
19 x .0295
.030
.005
.216
64
1/m
THHN
Spool sizes available in 500' & bulk.
Description: General Purpose Style Conductor - TFFN &THHN Wire - CSA & UL Listed
Use: Primarily used for general purpose building wire, fixture raceways, conduit - tubing
raceways and internal wiring of fixtures.
Conductor: Fully annealed stranded bare copper.
Temp. Rating: Temperature range is -105 ° C dry to 80 ° C in oil.
Features: Premium grade color coded PVC with a tough polyamide nylon armor. Resistant to:
oils, gasoline, water, acids, ozone, alkalines, sunlight & abrasion.
Color Code Chart
Black - BLK
White - WHT
Red - RED
Blue - BLU
Brown - BRN
Green Ye l l o w Orange Gray -
GRN
YEL
ORG
GRY
Pink - PNK
Purple - PUR
E X AMP LE
14 - THHN - 500 - BLU
Wire Gauge
Type of Wire
Spool Size
Color of Wire
Hi Tension Spark Plug Cable
7MMS
Stranding
Insulation
Thickness
20 ga. solid
.137"
N o m . Pounds
O . D . Per 1/M
Inches
Feet
.275"
50
Bulk
Quantity
Feet
1/m
Description: Hi Tension Spark Plug Cable
Jacket Material: Silicone
Insulation: Fiberglass
Core Installation: Copper Tin Plated
Jacket Color: Gray
Spool Sizes: 100 and 1,000
71