Page 61 62 63 64 65 66 67 68 69 70 71 Contents Explanation Of Wire Charts GPT Primary Wire & GXL Wire TXL Wire (Thin Wall) & Bonded Wire Duplex Primary Wire & Speaker Wire Combination Welding/Battery Cable & Bonded Booster Cable Starter / Ground Battery Cable & Trailer Cable Boat Cable, Test Lead Wire & Lamp Cord Service Cords Type SOOW, SJ, SJOOW & SOOW Vutron Multi-Conductor Communication Cables Coaxial Cable, Coaxial Cable Connectors & Mechanics Wire Machine Tool Wire (MTW), TFFN & THHN Wire Copyright © 2002 Terminal Supply Company, Troy, Michigan. 60 Useful Information For Wire Section Explanation of Wire Charts Basic Layout of the Wire Chart. 2 2 G P T Stranding Insulation Thickness Nom. O.D. Inches Pounds Per 1/M Feet Reel Quantity Feet 7x30 .023 .074 4 5/m Breakdown of Each Catagory 2 2 G P T Most of our wire part numbers are a combination of wire gauge, type of wire, spool size and then color. Not all numbers are entered in this way, so to avoid confusion there is an EXAMPLE (shown to the right) box for every type of wire s h o w i n g y o u h o w t o e n t e r t h e c o r r e c t p a r t n u m b e r. 7x30 Stranding Specs: This section specifies the number of strands (metal conductors) that are contained inside the jacket of the wire. The first number states that the wire you are interested in has 7 strands. The second number states that each one of those strands are 30 gauge wire. Insulation Thickness Insulation Thickness: This indicates the thickness of the jacket material that protects the metal conductor(s). Measurement is in inches. Example shown on the right. Stranding E X AMP LE 18 GPT - 100 - BLU Wire Gauge Type of Wire Spool Size Color of Wire .023 Nom. O.D. Inches Nominal Outer Diameter: This gives you the total width of the wire in inches. Example shown to the right. .074 Nom. O.D. Inches Nominal Outer Diameter: For bonded and multi-conductor wires, there are two separate numbers. The first one is the measurement of height of each wire separately. The second is the width of all the wires together. Measurements are in inches. Multi-Conductor Bonded .091x.195 .091x.195 .091 x .195 Pounds Per 1/M Feet Pounds Per 1/M Feet: This figure determines the amount of weight of the wire. Each wire is measured in pounds per one thousand feet. 4 Reel Quantity Feet Bulk Quantity Feet: This category specifies the largest volume of feet per reel you can purchase when buying in bulk. 5/m Please keep in mind that some of the charts in the wire section may be different or altered for added information on special product applications. 61 GPT Primary Wire & GXL Wire GPT Primary Wire 14 - Stock Colors White Black Red Blue Green Orange Yellow Brown Purple - WHT BLK RED BLU GRN ORG YEL BRN PUR Gray Pink Lt. Blue Tan Lt. Green - GRY - PNK - LBL - TAN - LGR E X AMP LE 18 GPT - 100 - BLU Type of Wire Insulation Thickness Nom. O.D. Inches 7x30 .023 .074 4 22 GPT 20 GPT 7x28 .023 .083 18 GPT 16x30 .023 .092 16 GPT 19x29 .023 14 GPT 19x25 .023 12 GPT 19x25 10 GPT 19x23 8 G P T 6 G P T 4 G P T Pounds Bulk Per 1/M Quantity Feet Feet Drum Quantity Feet 5/m 40/m 6 5/m 35/m 9 11 / m 50/m .104 12 9/m 40/m . 11 8 17 6/m 30/m .026 .144 25 4.5/m 20/m .031 .176 40 3.5/m 12/m 19x21 .037 .216 61 2.5/m 10/m 37x21 .060 .334 120 1/m -- 70x.0233 .057 .375 160 1/m -- Spool sizes are available in: 100', 500', 1000', bulk reel and drum. 6 ga. and 4ga. available in red and black only. When ordering Wire use this E X AMP L E to enter the correct part number Wire Gauge Stranding Spool Size Color of Wire Description: Polyvinyl Chloride (PVC) Insulated Use: Primarily used in the construction of interior wiring harnesses for passenger cars, trucks, tractors and off road vehicles. Conductor: Stranded, bare copper. Temp. Rating: Recommended temperature range is -40° C to 80° C. Features: Excellent resistance to abrasion. S.A.E. J1128, Type GPT • Chrysler Specification MS-3450 • Ford Specification ESF-M1L56A . GXL Wire 14 - Stock Colors White Black Red Blue Green Orange Yellow Brown Purple - WHT BLK RED BLU GRN ORG YEL BRN PUR Gray Pink Lt. Blue Tan Lt. Green - GRY - PNK - LBL - TAN - LGR Nom. O.D. Inches Pounds Per 1/M Feet Bulk Quantity Feet 7 5/m 20 GXL 7x28 .023 .085 18 GXL 16x30 .023 .094 9 5/m 16 GXL 19x29 .023 .103 12 5/m 14 GXL 19x27 .023 . 11 7 16 5/m 12 GXL 19x25 .026 .142 25 2.5/m 10 GXL 19x23 .026 .176 38 1/m 8 G X L 19x21 .037 .217 60 1/m 6 G X L 37x21 .043 .281 124 1/m Description: E X AMP LE 18 GXL - 100 - BLU Type of Wire Insulation Thickness Spool sizes are available in 100', 500', 1000' and Bulk Reel. 6 ga. available in red and black only. When ordering Wire use this E X A MP L E to enter the correct part number Wire Gauge Stranding Spool Size Color of Wire Cross Linked Polyethylene S.A.E. Specified Use: Primarily used in the construction of exterior wiring harnesses for passenger cars, trucks, tractors and off road vehicles. Ideal for heat, flame and abrasion resistance if required. Conductor: Stranded, bare copper. Temp. Rating: Recommended temperature range is -50° c to 125° c. Features: Excellent resistance to oil, flame and abrasion. TSC's GXL is labeled every 2 feet: Temperature, Type, Gauge & SAE. S.A.E. J1128, Type GXL • Chrysler Specification MS-5919 • Ford Specification ESB-M1L85-B • RVIA Approved Note: Keep in mind that BULK quantities of wire may vary from time to time. This is because vendor may change the amount of footage due to production. If you are interested in bulk it w i l l b e n e f i t y o u t o a s k o u r Tr o y w a r e h o u s e f o r a n y c h a n g e s i n b u l k q u a n t i t i e s . 62 TXL (Thin Wall) & Bonded Wire TXL Wire (Thin Wall) Stranding Insulation Thickness Nom. O.D. Inches Pounds Per 1/M Feet Bulk Quantity Feet 22-TXL 7x30 .016 .062 4 5/m 20-TXL 7x28 .016 .070 5 5/m 18-TXL 19x.0092 .016 .078 7 5/m 16-TXL 19x29 .016 .089 9 5/m 14-TXL 19x27 .016 .103 14 5/m 12-TXL 19x25 .018 .124 22 2.5/m 10-TXL 19x23 .020 .155 33 1/m Spool sizes are available in: 100', 500', 1000' and bulk reels. Description: Extra Thin Wall XLP Wire Use: Can be used in most automotive applications where higher heat resistance, small diameter and minimal weight is required. Conductor: Stranded, bare copper. Temp. Rating: Recommended temperature range is -40° C to 125° C. Features: Small dia. & high temperature rating is excellent for under hood applications. Conforms to tight areas S.A.E. J1128, Type TXL • Chrysler Specification MS-8288 • Ford Specification ESB-M1L123A 14 - Stock Colors White Black Red Blue Green Orange Yellow - WHT BLK RED BLU GRN ORG YEL Brown Purple Gray Pink Lt. Blue Tan Lt. Green - BRN PUR GRY PNK LBL TAN LGR E X AMP LE 18 TXL - 100 - BLU Wire Gauge Type of Wire Spool Size Color of Wire Bonded Wire # of Conductors Stranding Insulation Thickness Nominal O.D. Inches Pounds Per 1/M Feet Bulk Quantity Feet 18-2 B 2 16 x 30 .023 .094 x .188 16 14/m 16-2 B 2 19 x 29 .023 .105 x .210 22 12.5/m 14-2 B 2 19 x 27 .023 .122 x .244 32 10.5/m 12-2 B 2 19 x 25 .026 .138 x .280 48 6/m 18-3 B 3 16 x 30 .023 .094 x .282 26 12.5/m 16-3 B 3 19 x 29 .023 .105 x .315 33 10/m 14-3 B 3 19 x 27 .023 .122 x .366 47 8.5/m 12-3 B 3 19 x 25 .026 .147 x .421 74 4.5/m 18-4 B 4 16 x 30 .023 .094 x .376 32 10/m 16-4 B 4 19 x 29 .023 .105 x .420 44 8/m 14-4 B 4 19 x 27 .023 .122 x .488 64 6.5/m 12-4 B 4 19 x 25 .026 .143 x .361 105 2.5/m 16-5 B 5 19 x 29 .023 .105 x .420 55 5/m Spool sizes are available in: 100', 250', 500', 1000' & bulk reels. Description: Flat Multi-Conductor Bonded Wire Use: Primarily used in the construction of wiring harnesses for passenger cars, trucks, tractors and off the road vehicles. Use at 50 volts or less. Conductor: Stranded, bare copper. Insulation: Polyvinyl Chloride (P.V.C.) Temp. Rating: Recommended temperature range is -40° C to 80° C. Features: Excellent resistance to abrasion. S.A.E. J1128, Type GPT • Chrysler Specification MS-3450 • Ford Specification ESB-M1L56A Stock Colors 2 Conductor: Red & Black 3 Conductor: Green, Yellow & Brown 4 Conductor: Green, Yellow, Brown & White 5 Conductor: Green, Brown, Yellow, Brown & White E X AMP LE 18 - 2 B - 250 Wire Gauge # of Conductors Type of Wire Spool Size Only 16-2B and 16-4B available in tin plated marine grade. Call for more information. W hy us e 16-5 B onded W ire? W ith the a dditiona l brown (T ail L ight) wire, a cros s over wire on the back of a trailer is not neces s a ry. 63 Duplex Primary Wire & Speaker Wire Duplex Primary Wire Stock Colors 2 Conductor: White & Black # of Conductors Stranding Insulation Thickness Nominal O.D. Inches Pounds Per 1/M Feet Bulk Quantity Feet 18-2D 2 16 x 30 .023 .150 x .240 26 9/m 16-2D 2 19 x 29 .023 .162 x .265 36 8/m 14-2D 2 19 x 27 .023 .180 x .300 40 7/m 12-2D 2 19 x 25 .026 .210 x .360 70 5/m 10-2D 2 19 x 23 .031 .235 x .420 105 3.5/m 8-2D 2 19 x 21 .037 .290 x .520 150 2/m 16-3D 3 19 x 29 .023 .162 x .365 50 5/m 14-3D 3 19 x 27 .023 .180 x .420 70 4/m 12-3D 3 19 x 25 .026 .210 x .500 100 3/m 10-3D 3 19 x 23 .031 .235 x .595 145 2.5/m 16-4D 4 19 x 30 .023 .195 x .510 60 3.5/m 14-4D 4 19 x 27 .023 .210 x .560 84 3/m 3 Conductor: Green, White & Black Spool sizes are available in 100', 500', 1000' and Bulk Reels. 4 Conductor: Green, Red, White & Black Description: E X AMP LE 18 - 2 D - 100 Wire Gauge # of Conductors Type of Wire Spool Size For 12-2D with a red jacket and black and blue inner conductors use Part #12-2 DR-(spool size) Duplex Primary Wire Use: General purpose wiring of automobiles, boats, trucks, buses, tractors, trailers and other motor driven equipment. Conductor: Stranded bare copper. Temp. Rating: Temperature rating 105° C. 50 Volts or less. Features: Duplex wire is a cable composed of two or more insulated single conductor cables held together with an outer gray PVC jacket to protect against abrasion and weather. S.A.E. J1128, Type GPT Speaker Wire Standard Colors E X AMP LE 22 - 2 SW - 100 64 # of Conductors Type of Wire Insulation Thickness Nom. O.D. Inches Pounds Per 1/M Feet Bulk Quantity Feet 22-2 SW 7 x 30 .020 .070 x .145 6 5/m 20-2 SW 10 x 30 .025 .090 x .182 10 5/m 18-2 SW 16 x 30 .025 .095 x .192 11 5/m 16-2 SW 26 x 30 .025 .120 x .210 15 4/m 14-2 SW 41 x 30 .025 .140 x .285 26 3/m 12-2 SW 65 x 30 .030 .150 x .300 50 2.5/m Spool sizes are available in 100', 250', 500', 1000' and Bulk Reels. Clear P.V.C. One conductor has tinned stranding for polarity Wire Gauge Stranding Spool Size Description: Speaker Wire - Type PLT-1 Use: Primarily used for HI-FI and stereo speaker wire, lamps, radios and Jukeboxes. Conductor: Fully annealed 1 bare, 1 tin stranded copper. Features: Insulated with extra flexible clear P.V.C. for easy handling and installation. Welding - Battery Cable & Bonded Booster Cable Combination Welding & Battery Cable Stranding Insulation Thickness Nom. O.D. Inches Pounds Per 1/C Feet Bulk Quantity Feet SF 6 266 x 30 .075 .375 13 500 SF 4 420 x 30 .075 .430 18 500 SF 2 665 x 30 .076 .510 26 500 SF 1 836 x 30 .072 .540 32 500 SF 1/0 1064 x 30 .080 .610 41 500 SF 2/0 1330 x 30 .084 .670 51 500 SF 3/0 1665 x 30 .089 .740 63 500 SF 4/0 2109 x 30 . 11 0 .830 82 500 Stock Colors Red - RED Also available in Tinned Marine Grade When ordering wire please use the EXAMPLE below to determine the correct part . number Spool sizes are available in: 25', 50', 100' and 500' SF Description: Use: Conductor: Temp. Rating: Features: Black - BLK E X AMP LE 6 - 50 - RED Combination Welding & Battery Cable Primarily used for battery cable connections. Fully annealed stranded copper. Recommended Temperature Range is -70° F to 221° F. Super Flex cable is designed for low temperature conditions with an operating flexibility at minus 70° F. Suitable for all weather. 600 Volt Neoprene Super Flex Type of Wire Wire Gauge Spool Size Color of Wire Bonded Booster Cable Wire Gauge Stranding Insulation Thickness Nom. O.D. Inches . Pounds Bulk Per 1/C Quantity Feet Feet SF 44 two 4 AWG 420 x 30 .075 .425 x .975 35 500 SF 22 two 2 AWG 665 x 30 .076 .425 x 1.075 52 500 SF 11 two 1 AWG 836 x 30 .072 .530 x 1.025 65 500 Spool sizes are available in: 12', 25', 50', 100' and 500' Description: Bonded Booster Cable Use: Conductor: Temp. Rating: Features: Primarily used for jumper cables. Fully annealed stranded copper. Recommended Temperature Range is -70° F to 221° F. Super Flex cable is designed for low temperature conditions with an operating flexibility at minus 70° F. Suitable for all weather. 600 Volt TPR Super Flex TSC supplies booster cable ends (shown below) turn to page 138 for specifications and which style is best for your requirements. Stock Colors Blue Jacket with one red stripe on one conductor When ordering wire please use the EXAMPLE to enter the correct part number. E X AMP LE SF 44 - 50 Type of Wire Wire Gauge Spool Size Note: Keep in mind that BULK quantities of wire may vary from time to time. This is because vendor may change the amount of footage due to production. If you are interested in bulk it w i l l b e n e f i t y o u t o a s k o u r Tr o y w a r e h o u s e f o r a n y c h a n g e s i n b u l k q u a n t i t i e s . B attery Terminals continued on following page. 65 Starter / Ground Battery Cable & Trailer Cable Starter or Ground Battery Cable Stranding Insulation Thickness Nom. O.D. Inches Pounds Per 1/M Feet Bulk Quantity Feet 49 x .0231 .060 .334 12 1000 4 PVC 70 x .0233 .057 .375 16 1000 2 PVC 133 x .0226 .052 .450 25 1000 1 PVC 133 x .0254 .050 .490 31 500 1/0 PVC 133 x .0285 .047 .530 39 500 2/0 PVC 133 x .0315 .058 .595 48 500 6 PVC Stock Colors Red - RED Black - BLK When ordering wire please use the EXAMPLE to enter the correct part number. E X AMP LE 6 PVC - 100 - RED Wire Gauge Type of Wire Spool Size Spool sizes are available in: 100 and 500 Description: Color of Wire Use: Conductor: Temp. Rating: Features: PVC Insulated Starter or Ground Battery Cable Primarily used for battery cable connections. Stranded, bare copper. Temperature rating at 80° C, 50 Volts or less. Made of rope stranded copper, paper separated with a PVC jacket. Trailer Cable Bulk Outer Jacket # of Wires & Insulation N o m . Pounds Stranding Material Wire Gauge Thickness O . D . Per 1/M Quantity Inches Feet Feet & Color 1 4 - 7 N 6 / 12ga. 1 / 10ga. Internal Colors 1 4 - 7 T 7 / 14ga. 14-4N: 14ga. White, Black, Red & Brown. 14-6N: 14ga. White, Black, Yellow, Red, Green & Brown. 14-6P: 14ga. Black, Yellow, Red, Green, Brown & Blue. 14-6T: 14ga. White, Black, Red, Green, Brown & Blue. 14-7N: 6-12ga. Black, Yellow, Red, Green, Brown & Blue. 1-10ga. GPT: White. 14-7P: 14ga. White, Black, Yellow, Red, Green, Brown & Blue. 14-7T: 14ga. White, Black, Yellow, Red, Green, Brown & Blue. 14-7ABS: 4-12ga. Black, Brown, Green & Yellow. 2-10ga. Red & Blue. 1-8ga. White. 1 4 - 7 P 1 4 - 7 ABS E X AMP LE 14 - 7 N - 100 Wire Gauge # of Conductors Type of Jacket Spool Size 65 x 30 . .038 19 x 23 .690 29 500 Neoprene / Blue PVC Thin Wall / Black .560 19 x 27 .023 .375 16 500 7 / 14ga. 19 x 27 .038 .560 22 500 PVC / Black 4 / 12ga. 65 x 30 .138 .690 44 500 PVC / Green 2 / 10ga. 105 x 30 1 / 8ga. 168 x 30 1 4 - 6 T 6 / 14ga. 19 x 27 .023 .375 14 500 PVC Thin Wall / Black 1 4 - 6 P 6 / 14ga. 19 x 27 .035 .490 20 500 PVC / Black 1 4 - 6 N 6 / 14ga. 19 x 27 .035 .580 18 500 Neoprene / Blue 1 4 - 4 N 4 / 14ga. 19 x 27 .030 .460 11 500 Neoprene / Blue Spool sizes available in 50, 100 & 500. When ordering wire please use the EXAMPLE to enter the correct part number. Description: Multi-Conductor PVC & Neoprene Trailer Cable - S.A.E. J1128 Use: Primarily used for electrical trailer hookup. Conductor: Stranded, bare copper. Temp. Rating: Recommended temperature range is -20° F to 80° F. For PVC, -60° C to 105° F for neoprene. Features: Trailer cable single conductors are color coded for easy identification. This cable has excellent resistance to abrasion, oil, grease, acid and weather. Looking for specialty cable? Terminal Supply Co. has access to quality cable manufacturers which include: General Cable, Dearborn and Coleman Cable. From Vutron, Diesel Locomotive Cable to Stagelight Cable call us for a competitive quote. 66 Boat Cable, Test Lead & Lamp Cord Boat Cable Stranding Insulation Thickness Nom. O.D. Inches Pounds Per 1/M Feet Bulk Quantity Feet 16-2BC 26 x 30 .100 .190 x .310 43 6/m 14-2BC 41 x 30 .100 .200 x .340 61 5/m 12-2BC 65 x 30 .100 .220 x .380 82 4/m 10-2BC 105 x 30 .100 .240 x .420 11 2 2.5/m 16-3BC 26 x 30 .100 .190 x .430 72 4.5/m 14-3BC 41 x 30 .100 .200 x .470 92 3.5/m 12-3BC 65 x 30 .100 .220 x .530 122 3/m 10-3BC 105 x 30 .100 .240 x .600 192 1.5/m Stock Colors Outer Jacket: White 2 Conductors: Black & White 3 Conductors: Green, Black & White When ordering wire please use the EXAMPLE to determine the correct part number . E X AMP LE 14 - 3 BC - 100 Spool sizes are available in 100' & 500' and Bulk Reels. Description: Wire Gauge Tinned Multi-Conductor Boat Cable Use: Conductor: Temp. Rating: Features: Primarily used on boats for inverters, power generators and shore power connectors. Stranded, tinned copper. 105° C Dry - 75° C Wet. Flat multiple conductor insulated with a tough PVC jacket to meet SAE, UL, ABYC and coast guard requirements. UL File Number - E67078, 600 Volts. # of Conductors Type of Wire Spool Size F or wire s trippers , cutters a nd other va rious wire tools turn to our M a inte na nc e s e c tion. Test Lead Wire T LW - 5 0 Stranding Insulation Thickness Nom. O.D. Inches Pounds Per 1/C Feet Bulk Quantity Feet 65 x 36 .045 .140 1.0 50 Red and Black are supplied in 1 bag. Each color is 25 feet in length per bag for a total of 50 feet. Description: 18ga. Test Lead Wire Use: Primarily used for multimeters, analyzers, oscillators and other applications requiring extra flexible insulated wire. Conductor: Stranded tinned soft copper. Temp. Rating: -20° C to +60° C, 5000 volts. Features: Flexible plastic insulation is durable and has a high-gloss finish. Breakdown voltage is 20,000V - Suggested working voltage is 5,000V. Stock Colors Red Black Lamp Cord 18-2 LC Stranding Insulation Thickness Nom. O.D. Inches Pounds Per 1/M Feet Bulk Quantity Feet 41 x 34 .019 . 11 0 x . 2 1 0 6 250' Stock Colors Stocked on 250' Spools Description: Use: Conductor: Temp. Rating: Features: SP-1 (2 Conductor Appliance Cord) Primarily used for lamps, stereos, and jukeboxes. Fully annealed stranded, bare copper. Recommended temperature range is -20° C - +60° C. Jacket insulation is premium grade P.V.C. with polarity ridge for easy identification. Type SPT-1 300 Volts - 10 Amp capacity UL / CSA Listed. (Other sizes and colors available upon request.) White - WHT Black - BLK Brown - BRN When ordering wire please use the EXAMPLE to determine the correct part number . E X AMP LE 18 - 2 LC - 250 - BLK Wire Gauge Type of Wire Spool Size Color of Wire # of Conductors 67 Service Cords Type SOOW, SJ, SJOOW & SOOW Vutron Service Cord Type SOOW, SJ & SJOOW Service Cord Type Type - SOOW Type - SJ Type - SJOOW # of Wires & Wire Gauge Stranding Current Amps Nom. O.D. Inches Pounds Per 1/M Feet Nom. O.D. Inches Pounds Per 1/M Feet Nom. O.D. Inches Pounds Per 1/M Feet 1 8 - 2 2 / 18ga. 16 x 30 10 .345 75 .295 54 .295 56 1 8 - 3 3 / 18ga. 16 x 30 10 .365 87 .320 70 .320 72 1 8 - 4 4 / 18ga. 16 x 30 7 .390 102 .355 92 .355 96 1 6 - 2 2 / 16ga. 26 x 30 13 .370 78 .320 66 .320 69 1 6 - 3 3 / 16ga. 26 x 30 13 .390 105 .345 89 .345 92 1 6 - 4 4 / 16ga. 26 x 30 10 .415 120 .385 11 2 .385 11 6 1 4 - 2 2 / 14ga. 41 x 30 18 .500 151 .350 87 .350 92 1 4 - 3 3 / 14ga. 41 x 30 18 .530 176 .380 106 .380 11 2 1 4 - 4 4 / 14ga. 41 x 30 15 .570 210 .415 144 .415 136 1 2 - 2 2 / 12ga. 65 x 30 25 .575 201 .425 138 N/A N/A 1 2 - 3 3 / 12ga. 65 x 30 25 .600 235 .450 173 .450 189 1 2 - 4 4 / 12ga. 65 x 30 20 .650 291 .500 214 .500 225 1 0 - 2 2 / 10ga. 105 x 30 30 .625 245 N/A N/A N/A N/A 1 0 - 3 3 / 10ga. 105 x 30 30 .600 307 .660 250 .660 275 1 0 - 4 4 / 10ga. 105 x 30 25 .710 360 .680 320 .680 344 All service cords are available in 50' 100' and 250' ft. Spools. Description: Stock Colors 2 Conductors: Black & White. 3 Conductors: Black,White & Green. 4 Conductors: Black,White, Green & Red. E X A MP L E 18 - 2 SJ - 250 Wire Gauge # of Conductors Type of Wire Spool Size Multi-Conductor Type SOOW, SJ & SJOOW Service Cords Use: Primarily used for portable appliances, tools, small motors, lighting, battery chargers, . openers, washing machines, refrigerators and sound equipment. garage door Type - SOOW: 600 Volt -40° C to +90° C. Oil resistant neoprene jacket, Also available in 8ga. through 4ga. - 2 to 4 conductors. Type - SJ: 300 Volt -40° C to +60° C. Junior hard service rubber insulated portable cord. Type - SJOOW: 300 Volt -40° C to +90° C. Same as Type-SJ, but neoprene oil resistant compound outer jacket. To order the correct part# for all service cords; please use the EXAMPLE chart. Service Cord Type - SOOW Vutron # of Wires & Wire Gauge Stranding Current Amps Nom. O.D. Inches Pounds Per 1/M Feet 1 8 - 3 3 / 18ga. 16 x 30 10 0.380 82 Stock Colors 1 6 - 2 2 / 16ga. 26 x 30 13 0.390 82 2 Conductors: Black & White. 3 Conductors: Black,White & Green. 4 Conductors: Black,White, Green & Red. 1 6 - 3 3 / 16ga. 26 x 30 13 0.400 97 1 6 - 4 4 / 16ga. 26 x 30 10 0.425 111 1 4 - 3 3 / 14ga. 41 x 30 18 0.550 165 To order the correct part# for all service cords; please use the EXAMPLE chart. 1 4 - 4 4 / 14ga. 41 x 30 15 0.590 186 1 2 - 3 3 / 12ga. 65 x 30 25 0.615 222 1 2 - 4 4 / 12ga. 65 x 30 20 0.670 275 1 0 - 4 4 / 10ga. 104 x 30 25 0.740 339 E X AMP LE 18 - 2 SOOW - V - 250 Wire Gauge # of Conductors Type of Wire Spool Size All service cords are available in 50' 100' and 250' ft. Spools. Looking for more conductors or larger s izes ? C all our toll free numbe r for produc t a v a ila bility 1 800 989 9632. 68 Description: Multi-Conductor Type SOOW Vutron Service Cord Use: Primarily used for portable appliances, tools, small motors, lighting, battery chargers, garage door openers, washing machines, refrigerators and sound equipment. Features: 600 Volt -50*C +105*C. Excellent flexibility even in cold temperatrues and resistant to weather, flame and ozone. Multi-Conductor Communication Cables Unshielded Communication Cable # of Wires & Gauge Stranding Insulation Thickness Nom. O.D. Inches Pounds Per 1/M Feet CC-202 2 / 20ga. 7 x 28 .030 .192 21 CC-203 3 / 20ga. 7 x 28 .030 .216 27 CC-204 4 / 20ga. 7 x 28 .030 .235 36 CC-205 5 / 20ga. 7 x 28 .030 .254 46 CC-207 7 / 20ga. 7 x 28 .030 .275 56 CC-182 2 / 18ga. 16 x 30 .030 .222 29 CC-183 3 / 18ga. 16 x 30 .030 .232 40 CC-184 4 / 18ga. 16 x 30 .030 .253 49 CC-185 5 / 18ga. 16 x 30 .037 .275 58 CC-187 7 / 18ga. 16 x 30 .037 .298 77 CC-162 2 / 16ga. 1 9 x . 0 11 7 .030 .268 40 CC-163 3 / 16ga. 1 9 x . 0 11 7 .030 .283 51 CC-164 4 / 16ga. 1 9 x . 0 11 7 .045 .306 95 CC-165 5 / 16ga. 1 9 x . 0 11 7 .045 .334 11 4 CC-167 7 / 16ga. 1 9 x . 0 11 7 .045 .364 130 Standard Colors for Conductors 2 Conductor: Black & Clear 3 Conductor: Black, Clear & Red 4 Conductor: Black, Clear, Red & Green 5 Conductor: Black, Clear, Red, Green & Brown 7 Conductor: Black, Clear, Red, Green, Brown, Blue & Orange When ordering wire please use the EXAMPLE to enter the correct part number. CC Type of Wire E X AMP LE - 20 2 - 100 Wire Gauge # of Conductors Spool Size Spool sizes are available in 100', 500' & 1000' Description: Multi-Conductor Communication Cable - Unshielded Use: Primarily used for public address systems, intercoms, internal telephones and remote control circuits. Conductor: Fully annealed stranded tinned copper. Temp. Rating: Recommended temperature range is -20° C to +80° C - 300V. Features: Jacket is made of PVC gray, to protect conductors from normal wear. UL style 2464 • NEC article 800 type CM • OSHA acceptalbe • Passes CSA FTY & UL's - • 70,000 BTU Vertical flame test • CSAPCC (CSA 60*C) Shielded Communication Cable Insulation Thickness Nom. O.D. Inches Pounds Per 1/M Feet 28 .030 .203 23 x 28 .030 .213 30 x 28 .030 .234 36 30 .030 .229 30 30 .030 .247 40 30 .030 .238 50 .030 .314 55 .030 .332 60 # of Wires / Gauge - Ground Stranding CCS-202 2 / 20ga.- 20 7 x CCS-203 3 / 20ga.- 20 7 CCS-204 4 / 20ga.- 22 7 CCS-182 2 / 18ga.- 20 16 x CCS-183 3 / 18ga.- 20 16 x CCS-184 4 / 18ga.- 20 18 x CCS-162 2 / 16ga.- 18 1 9 x . 0 11 7 CCS-163 3 / 16ga.- 18 1 9 x . 0 11 7 Spool sizes are available in 100', 500' & 1000' Description: Multi-Conductor Communication Cable - Shielded Use: Primarily used for Industrial equipment controls, computers, broadcast and sound systems. Conductor: Fully annealed stranded tinned copper. Temp. Rating: Recommended temperature range is -20° C to +80° C - 300V. Features: Jacket is made of PVC gray, to protect conductors from normal wear. Shield is 100% Flexfoil Aluminum / Polyester 25% overlap, foil facing out. UL style 2464 •NEC article 800 type CM •OSHA acceptalbe •Passes CSA FTY & UL's 70,000 BTU Vertical flame test • CSAPCC (CSA 60*C) Standard Colors for Conductors 2 Conductor: Black & Clear 3 Conductor: Black, Clear & Red 4 Conductor: Black, Clear, Red & Green 5 Conductor: Black, Clear, Red, Green & Brown 7 Conductor: Black, Clear, Red, Green, Brown, Blue & Orange When ordering wire please use the EXAMPLE to enter the correct part number. CCS Type of Wire E X AMP LE - 20 2 - 100 Wire Gauge # of Conductors Can't find the cable for your application? As an authorized distributor for General Cable and Alpha Wire, we have quick and competitive access to a broad range of communication, control and coaxial cable. Call our troy office for a quick response of specialty wire and cable products. Spool Size 69 Coaxial Cable, Coaxial Cable Connectors & Mechanics Wire Coaxial Cable Inner Conductor Dielectric Insulation Shield & Type Nominal % Coverage Impedance ohms AWG Strand Material Material Nom. O.D. Inches Material Nominal % Coverage RG-58U PVC / BLK .195 53 20 Solid Bare Copper Solid Polyethylene . 11 6 Tinned Copper Braid 81 RG-58AU PVC / BLK .195 50 20 19 x .0071 Tinned Copper Solid Polyethylene . 11 6 Tinned Copper Braid 95 RG-59U PVC / BLK .242 75 22 Solid Copper Coated Steel Solid Polyethylene .146 Bare Copper Braid 95 RG-6U PVC / BLK .240 75 18 Solid Copper Coated Steel Cellular Polyethylene .180 Flexfoil Shield 100 RG-58U RG-58AU RG-6U Description: When ordering wire please use the EXAMPLE to enter the correct part number. E X AMP LE RG - 58U - 100 Type of Wire RG-59U Single Conductor - Coaxial Cable RG-58U Primarily used for radio frequency and broadcast. RG-58AU Primarily used for radio frequency and broadcast. RG-59U Primarily used for radio frequency, signal transmission, MATV, CATV, local area network, citizen band radio, computer applications and cathode ray tube (CRT). RG-6U Primarily used for RF signal transmission, digital video, CATV, MATV, local area network and FM Broadcast. Spool Size Spool sizes are available in: 100 and 1,000 feet. Coaxial Cable Connectors Fig. Cable Type Description A 58 BNC - Plug - Crimp type CMC-3002 B 59 BNC - Plug - Crimp type CMC-4001 C 58 TNC - Plug - Crimp type CMC-4002 D 59 TNC - Plug - Crimp type CMC-7002 E 59 F - Series - Crimp type CMC-7001 F 6 F - Series - Crimp type CMC-3001 Mechanics Wire Stranding AWG Nom. O.D. Inches Pounds Per Spool Reel Quantity Feet MW-18 Solid 18 .048 5 830 MW-16 Solid 16 .060 5 480 MW-14 Solid 14 .073 5 295 Description: Mechanics Wire Use: Mechanics wire has over 1000 uses to secure just about anything. Standard color Black Conductor: Single conductor black finish 70 Machine Tool Wire (MTW), TFFN, THHN, & Spark Plug Cable Machine Tool Wire Stranding Insulation Thickness Nom. O.D. Inches Pounds Per 1/M Feet Bulk Quantity Feet 18 MTW 16 x 30 .031 . 11 0 10 5/m 16 MTW 1 9 x . 0 11 7 .031 .122 14 5/m 14 MTW 19 x .0147 .031 .136 20 5/m 12 MTW 19 x .0185 .031 .155 27 3/m 10 MTW 19 x .0234 .031 .180 43 2/m 8 M T W 19 x .0295 .031 .246 72 500 6 M T W 19 x .0372 .030 .260 120 500 4 M T W 19 x .0469 .040 .331 150 500 Color Code Chart Black White Red Blue Brown Green Ye l l o w Orange Gray Pink Purple Light Blue Spool sizes are available in 500 and bulk. Description: Single Conductor - Machine Tool Wire (MTW) Use: Primarily used for motor & transformer lead, external wiring of machinery and building wire. Conductor: Fully annealed stranded bare copper. Temp. Rating: Recommended temperature range is -40° C to +90° C, 600V. Features: Outstanding resistance to oil, flame, abrasion, moisture, corrosion and heat. UL and NMTBA type MTW/AWM •CSA AWM •Passes VW-1 vertical flame test •OSHA acceptable. - BLK WHT RED BLU BRN GRN YEL ORG GRY PNK PUR LBL When ordering wire please use the EXAMPLE to enter the correct part number. E X AMP LE 18 MTW - 500 - BLU Wire Gauge Type of Wire Spool Size Color of Wire TFFN & THHN Wire Insulation Thickness P.V.C. Nylon Stranding 18 TFFN 16 N o m . Pounds O . D . Per 1/M Inches Feet Bulk Quantity Feet 16 x 30 .015 .004 .090 8 2.5/m TFFN 1 9 x . 0 11 7 .015 .004 .104 12 2.5/m 14 THHN 19 x .0147 .015 .004 . 11 6 17 2.5/m 12 THHN 19 x .0185 .015 .004 .135 25 2.5/m 10 THHN 19 x .0234 .020 .004 .169 40 2.5/m 8 19 x .0295 .030 .005 .216 64 1/m THHN Spool sizes available in 500' & bulk. Description: General Purpose Style Conductor - TFFN &THHN Wire - CSA & UL Listed Use: Primarily used for general purpose building wire, fixture raceways, conduit - tubing raceways and internal wiring of fixtures. Conductor: Fully annealed stranded bare copper. Temp. Rating: Temperature range is -105 ° C dry to 80 ° C in oil. Features: Premium grade color coded PVC with a tough polyamide nylon armor. Resistant to: oils, gasoline, water, acids, ozone, alkalines, sunlight & abrasion. Color Code Chart Black - BLK White - WHT Red - RED Blue - BLU Brown - BRN Green Ye l l o w Orange Gray - GRN YEL ORG GRY Pink - PNK Purple - PUR E X AMP LE 14 - THHN - 500 - BLU Wire Gauge Type of Wire Spool Size Color of Wire Hi Tension Spark Plug Cable 7MMS Stranding Insulation Thickness 20 ga. solid .137" N o m . Pounds O . D . Per 1/M Inches Feet .275" 50 Bulk Quantity Feet 1/m Description: Hi Tension Spark Plug Cable Jacket Material: Silicone Insulation: Fiberglass Core Installation: Copper Tin Plated Jacket Color: Gray Spool Sizes: 100 and 1,000 71