Low Profile Ceiling Mount Speaker/Strobe and S S P K C L P Ceiling or Wall Mount Speaker Applications S E R I E S The Gentex SSPK24CLP is a ceiling mount, selectable candela speaker/strobe and the SSPKCLP is a ceiling or wall mount speaker designed to meet code requirements for audio, visual and voice communications. The SSPKCLP Series are quality speaker products that offer both dependable evacuation signaling and visual alarms, or a combination of both. The SSPK24CLP has high output tamperproof candela selections are 15, 30, 75, 95 and 115. The SSPKCLP Series can be mounted in a 4” square x 2-1/8” deep back box, an extension ring is not needed. The SSPKCLP Series provides a 25 or 70.7 VRMS speaker with field selectable power taps of 1/8W, 1/4W, 1/2W, 1W, 2W or 4W. The SSPK24CLP strobes can be synchronized by using the Gentex Synchronization Control Module, FACP’s or power supplies that include the Gentex Synchronization Protocol. The SSPKCLP Series grills are constructed of high impact textured plastic. The SSPKCLP is warranted for 3 years from the date of purchase. The SSPKCLP devices are UL 1971 listed for use with fire protective signaling systems. SSPK24CLPW SSPKCLPR Product Listings Standard Features • • • • • • • • • • • • • • 24VDC Tamperproof Selectable Candela Selections of 15, 30, 75, 95 and 115. Unit Dimension: 6.1” Square X 1.88” Deep SSPK24CLP Ceiling Mounting to a standard 4” X 2-1/8" Deep Back Box • UL1480, UL 1971 and UL 2043 Listed SSPKCLP Ceiling or Wall Mounting to a standard 4” X 2-1/8" Deep Back Box • CSFM # 7320-0569:137 High Quality dBA Output (Intelligible) • BS&A/MEA # 580-06-E Vol. 3 Frequency Range 400-4000Hz Product Compliance Screw Terminals, Separate In/Out Wiring (12-18 Gauge) Field Selectable Power Taps: 1/8W, 1/4W, 1/2W, 1W, 2W, 4W • Americans with Disabilities Act (ADA) • NFPA 72 Speaker Voltage 25 or 70.7 VRMS Standard, Field Selectable To Synchronize Use the Gentex Synchronization Control Module Tamperproof Grill Faceplate Available in Red or Off-White UL 1480/UL 1971/UL 2043 Listed for Fire Protective Service/Signal for Hearing Impaired Xenon Strobe Maintains Constant Flash Rate (1Hz) Regardless of Input Voltage1 Low Profile Evacuation Speakers and Speaker/Strobes Model Number Description Part Number SSPKCLPR Speaker 904-1445-002 SSPKCLPW Speaker 904-1446-002 SSPK24CLPR Speakers/Strobe 904-1441-002 SSPK24CLPW Speaker/Strobe 904-1443-002 Notes: The SSPKCLP Series is not listed for outdoor use. Operating temperature: 32°to 120°F (0° to 49° C). Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products (see technical bulletin number 014). "R" = Red Faceplate "W" = Off-White Faceplate "P" = Plain (no lettering) Available with all models. Input Watts 1/8 1/4 1/2 1 2 4 Speaker dBA @ 10 ft. 25 Volts 70.7 Volts 74.6 dBA 73.7 dBA 77.7 dBA 76.7 dBA 80.5 dBA 79.6 dBA 83.1 dBA 82.5 dBA 85.6 dBA 85.4 dBA 87.9 dBA 87.9 dBA SSPK24CLP CEILING MOUNT Candela 15cd 30cd 24 VDC 72mA 88mA 120mA 130mA UL Max1 STROBE CURRENT RATINGS 75cd 95cd 115cd 176mA 200mA 214mA 272mA 318mA 360mA 1 RMS current ratings are per UL average RMS method. UL maximum current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units) (8-17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units) (8VDC for 12VDC units). For audibles the maximum current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. S S P K C L P S E R I E S SSPK24CLP Candela Selection Power Tap Selection SSPKCLP Mounting Diagram Mounts to a standard 4" square x 2-1/8"back box or to Gentex GBLP surface back box Adjust brightness by turning dial with screwdriver. Candela selection is displayed on front of unit. Wiring Diagram NOTE: DO NOT USE LOOPED WIRE UNDER TERMINALS. BREAK WIRE RUN TO PROVIDE SUPERVISION OF CONNECTION. *MAX. WIRE DISTANCE (IN FEET)= PANEL VOLTAGE — DEVICE MINIMUM VOLTAGE X WIRE CONDUCTIVITY TOTAL CURRENT DRAW *CAUTION: APPLIES ONLY TO REGULATED SUPPLIES . NOTICE: POWER IS SUPPLIED TO DEVICES WHEN CONTROL PANEL IS LATCHED. Architect & Engineering Specifications The fire alarm speaker shall be Gentex SSPKCLP, SSPK24CLP or equivalent. The speaker shall be capable of producing alarm tones or voice on all 25 or 70.7 VRMS audio systems. The speaker shall provide incremental tap settings of 1/8, 1/4, 1/2, 1, 2 or 4 watts. Minimum dBA ratings at 1/4 watt shall be 76.7dBA and at 4 watts 87.9dBA. Tap settings shall be adjustable with field selectable jumper pins. The speaker shall also have an optional visual signal capability. The visual signal shall have a 1Hz flash rate regardless of input voltage. All field wiring connections shall be made via separate in-out terminal connections and the speaker or speaker strobe shall be UL, CSFM and BS&A/MEA listed and comply with all local, state and federal fire alarm codes/standards. 12 units per carton 17 pounds per carton Important Notice: These materials have been prepared by Gentex Corporation ("Gentex") for informational purposes only, are necessarily summary, and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties, express or implied, that these materials are complete and accurate, up-to-date, or in compliance with all relevant local, state and federal laws, regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws, regulations and rules and the application of such laws, regulations and rules to particular fact patterns. Each person's activities can differently affect the obligations that exist under applicable laws, regulations or rules. Therefore, these materials should be used only for informational purposes and should not be used as a substitute for seeking professional legal advice. Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. 551-0065-02